Loading...
HomeMy WebLinkAboutC4 STORMT/L T/L T/L T/L T/L T/L T/L R W R W R W BM ELEV = 852.27' 6''W6''W 6''SS6''SS GAS GASGAS FDC UGE&T UGE&T UGE&T UGE&T UGE&T UGE&T UGE&T UGE&T UGE UGT WIV 4''W 0+00 1+00 2+00 3+00 4+00 4+40 0+00 1+ 00 2+00 3+00 3+91 0+00 0+52 0+00 1+00 1+94 92.16' 91.5' 0+00 1+00 1+33 LINE 'C' LINE 'C' LINE 'B' LINE 'B' LINE 'A 1' LINE 'D' LINE 'E' ADJUST TO FINISH GRADE REMOVE EX. CURB INLET AND REPLACE G=848.98 ISOLATION ROW 1 ISOLATION ROW 2 FFE=853.5 100 YR. WSE IN DETENTION=844.33 EMERGENCY SPILL EL.=847.85 MFPG/MLAG=849.85 MC-4500 CHAMBERS L=91.5' W=92.5' 2 ROWS 21 8 ROWS 20 BOTTOM EL.=841.85 100 YR WSE=844.33' EMERGENCY SPILLWAY EL.=847.85' INITIAL DATE DPOR PM DES DRW Engineering Associates, Inc. CEI PROJECT NO. NO. DATE REVISIONS 10/10/14 10/17/14 DESCRIPTION BZA SUBMITTAL ADLS/ DP SUBMITTAL 2/26/15 SUBMITTAL REVISED PER COMMENTS 4/30/15 SUBMITTAL REVISED PER COMMENTS 6/4/15 BID/PERMIT SET JOB # PROJ#28436.0 DRAWING: 28436 Storm.dwg LAST SAVED BY: RNEDKOV LOCATION: C:\CEI-CAD\Vault\28436.0 CLA - 116th St & College Av e - Carmel, IN\Drawings\Design\28436 Storm.dwg 0 20' 30' 40' SCALE IN FEET GRADING DETAILS 23A GRATE INLET 72A NYLOPLAST 24" DRAIN BASIN WITH LIGHT DUTY 24" PEDESTRIAN GRATE-LOCK ASSEMBLY - TYPE B (2499CGP) 72B NYLOPLAST 24" DRAIN BASIN WITH LIGHT DUTY 24" SOLID GRATE-LOCK ASSEMBLY - TYPE B (2499CGCL) 73G RECESSED WALK OFF MAT. (SEE ARCHITECTURAL PLUMBING PLAN FOR ADDITIONAL INFORMATION) 73H DRAINAGE MANHOLE (PER HAMILTON COUNTY STD. DETAIL D-20 SIZED PER HAMILTON COUNTY CHART D-18) 73I EXISTING DRAINAGE MANHOLE 299 MODIFICATION OUTLET CONTROL PLATE 73J SNOUT (WATER QUALITY DEVICE) WITH ATTACHED ANTI-MICROBIAL TREATED OIL REDUCING BIO-SKIRT ® 73K TRENCH DETAIL FOR CITY STORM SEWER (STD DRAWING 10-28) GRADING NOTES 18F CONNECT TO EXISTING STORM DRAIN PIPE. 18G CONNECT TO EXISTING STORM DRAIN STRUCTURE. 73A CONNECT 4" HDPE PIPE TO TRENCH DRAIN( SEE PLUMBING PLAN FOR EXACT LOCATION) 73B CONNECT 8" HDPE PIPE TO ROOF DRAIN. (SEE PLUMBING PLAN FOR EXACT LOCATION) 73E CONNECT 4" HDPE PIPE TO DOORWAY TRENCH DRAIN. (SEE PLUMBING PLAN FOR EXACT LOCATION) 73F CONNECT 4" HDPE PIPE TO DRAIN PIPE FROM RAISED CONCRETE PLANTERS IN COURTYARD. 73G PIPES AND FITTINGS THAT ARE INSTALLED WITHIN CITY RIGHT-OF-WAY, SHALL BE REINFORCED CONCRETE CONFORMING TO ASTM C443. IF THE STORM SEWER PIPE IS TO BE PLACED WITHIN A ROAD RIGHT-OF-WAY OR IN AN AREA SUBJECT TO LOADING, THE PIPE AND FITTINGS SHALL BE CLASS III CONCRETE 73H ROOF DRAIN PER ARCHITECTURAL PLANS 73J MAINTENANCE MANHOLE PER STORMTECH SPECIFICATIONS. PROPOSED PROPERTY LINE/RIGHT OF WAY LINE CONTOUR ELEVATIONS STORM DRAIN XXX EXISTING FIRE HYDRANT LOCATED AT THE NE CORNER OF THE SITE ELEVATION = 852.27' SITE BENCHMARK NO PRESENT FLOODWAYS ON SITE 6/2/15 UNDERGROUND DETENTION SHALL BE INSTALLED BY THE SELLER