HomeMy WebLinkAboutC5 ST PROFILE 1LINE B PROFILE 835 840 845 850 855 860 835 840 845 850 855 860 0+00 849.20 851.12 0+50 853.30 852.61 1+00 852.77 852.88 1+50 852.90 852.97 2+00 853.41 853.23 2+50 852.92 852.80 3+00 852.47 852.12 3+50 851.87 851.61 4+00 852.67 851.45 ST-27 STA:2+90.14 RIM:852.20 18" IN 843.10 18" OUT 843.00 100YR HGL 845.33' ST-26 STA:3+56.68 RIM:851.55 18" IN 842.67 18" OUT 842.52 100YR HGL 845.03' ST-25 STA:3+91.78 RIM:852.45 18" IN 842.34 18" OUT 842.24 100YR HGL 844.64' 158.23 LF 18" HDPE @ 0.50% (PIPE#B28) 66.54 LF 18" HDPE @ 0.50% (PIPE#B27) 35.12 LF 18" HDPE @ 0.50% (PIPE#B26) 47.96 LF 18" HDPE @ 0.50% (PIPE#B25) ST-24 STA:4+39.52 RIM:852.26 18" IN 842.00 12" IN 848.03 SUMP 840.00 100YR HGL 844.33' 78.39 LF 12" HDPE @ 1.00% (PIPE#B30) 52.90 LF 15" HDPE @ 1.00% (PIPE#B29) ST-29 STA:0+79.04 RIM:852.20 12" IN 844.88 15" OUT 844.66 100YR HGL 845.74' ST-28 STA:1+31.91 RIM:852.20 15" IN 844.13 18" OUT 843.89 100YR HGL 845.57' ST-30 STA:0+00.65 RIM:849.20 12" OUT 845.67 100 YEAR HGL 846.42' LINE A (1) PROFILE 835 840 845 850 855 860 835 840 845 850 855 860 0+50 848.85 849.85 1+00 850.05 850.11 131.70 LF 12" HDPE @ 0.33% (PIPE#1) EXISTING ST-0 STA:1+31.94 RIM:849.13 12" IN 845.14 100YR HGL 845.74' ST-1 STA:0+00.25 RIM:848.12 12" OUT 845.57 SUMP 843.57 100YR HGL 846.43' LINE E PROFILE 835 840 845 850 855 860 835 840 845 850 855 860 0+50 849.74 850.39 1+00 849.74 850.10 1+50 849.14 849.77 ST-7 STA:0+01.05 RIM:849.46 18" OUT 845.46 SUMP 843.46 100YR HGL 845.74' ST-6 STA:1+76.93 RIM:848.80 18" IN 844.58 18" OUT 844.48 SUMP 842.48 100YR HGL 845.87' ST-5 STA:1+93.84 RIM:848.66 18" IN 844.40 100YR HGL 845.44' 175.88 LF 18" HDPE @ 0.50% (PIPE#E7) 16.91 LF 18" HDPE @ 0.50% (PIPE#E6) 0.9' INITIAL DATE DPOR PM DES DRW Engineering Associates, Inc. CEI PROJECT NO. NO. DATE REVISIONS 10/10/14 10/17/14 DESCRIPTION BZA SUBMITTAL ADLS/ DP SUBMITTAL 2/26/15 SUBMITTAL REVISED PER COMMENTS 4/30/15 SUBMITTAL REVISED PER COMMENTS 6/4/15 BID/PERMIT SET JOB # PROJ#28436.0 DRAWING: 28436 Storm.dwg LAST SAVED BY: RNEDKOV LOCATION: C:\CEI-CAD\Vault\28436.0 CLA - 116th St & C ollege Ave - Carmel, IN\Drawings\Design\28436 Storm.dwg EXISTING GRADE FINISH GRADE FINISH GRADE EXISTING GRADE HORIZONTAL SCALE 1"=30' VERTICAL SCALE 1"=3' HORIZONTAL SCALE 1"=30' VERTICAL SCALE 1"=3' FINISH GRADE EXISTING GRADE HORIZONTAL SCALE 1"=30' VERTICAL SCALE 1"=3' BMP SNOUT EXISTING BMP SNOUT BMP SNOUT 6" EXISTING SANITARY SEWER STUB IN STEEL ENCASEMENT 100 YEAR HGL 100 YEAR HGL 100 YEAR HGL 6" SANITARY SEWER EXISTING 18" STORM SEWER THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. 6" SANITARY SEWER 6" WATER LINE 6/2/15