Loading...
HomeMy WebLinkAboutA1.2 - REFLEC CEILING_ELECTRICAL PLANSProject Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A 4 6 0 3 2 By: Architect: Architecture / Project Management: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) JD A / E N D E A V O R Drawn By Checked ByPrint Date Revisions: 20 0 S O U T H R A N G E L I N E R O A D SU I T E 2 0 9 IN D I A N A D E S I G N C E N T E R SUITE 209 A1.2 REFLEC CEILING/ ELECTRICAL PLANS Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 8/26/15 CONSTRUCTION DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, JAMES R. STUTZMAN, AIA, CARMEL. 8/26/15 STATE RELEASE SET N KEY PLAN SCALE: N.T.S. SECOND FLOOR D D D D D D D 2 A4.1 10'-10 1/2" 10'-10 1/2" OPEN OPEN 10'-10 1/2"10'-10 1/2"10'-10 1/2" 10'-10 1/2" CP1 CP2 CP3 CP3 CP3 CP3 CP4 CP5 CP5 CP5 CP5 CP2 CP2 CP2 CP2 CP7 CP7 +12' aff N N NN N N N N N N N N N N N N N N N N N N N N NN N N NN N N N N N N N N N N N N N N N N N F GE 8 8.1 10 11 9.1 8.15 9.9 10.9 10.85 9 F GE 8 8.1 10 11 9.1 8.15 9.9 10.9 10.85 9 F EP2 EP3 EP1 EP4 EP5 EP5 EP5 EP5 EP5 EP5 EP5 EP5 EP5 RECEPTION 201 OPEN OFFICE AREA 204 OFFICE 207 CONFERENCE ROOM 208 N OFFICE 210 +42" AFF OFFICE 209 OFFICE 205 OFFICE 211 CONFERENCE ROOM 202 COFFEE BAR 203 N N N N N N N N N N N NN N N N N NNN N N N +66"N +44"N N N N N HALLWAY 206 IT CLOSET 212 +60"N +60"N+60"N +60"N +60"N +60"N +60"N+60"N +60"N +60"N N +60"N+60"N +60"N+60"N N NN WORKSTATIONS 6'X6' WORKSTATIONS 6'X6' N N N N N N COPIER NN N N N N WORKSTATIONS 6'X6'WORKSTATION 6'X6' CEILING HEIGHT IS NOTED BY BENCHMARK UNLESS NOTED OTHERWISE. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. ALL WALLS GO TO 13'-0" AFF UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. GENERAL CEILING NOTES:CEILING PLAN NOTES: LOCATE NEW SMOKE DETECTORS DUE TO LIGHT FIXTURE LAYOUT. INFORM ARCHITECT AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. CP1 7. 6. 5. 4. 1. 2. 3. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. ARCHITECT REVIEW IS FOR AESTHETIC REVIEW ONLY. NL EMERGENCY/NIGHTLIGHT LOCATION. TWO WAY SWITCH. GYPSUM BOARD BULKHEAD. NEW 2 X 2 LAY-IN GRID SUSPENSION SYSTEM. REFLECTED CEILING LEGEND: CP2 LOCATION OF SHOWROOM LIGHTING CONTROLS. ALIGN AND STACK CONTROLS AS NEEDED. CP3 SUSPENDED ACOUSTICAL CEILING SYSTEM WITH RECESSED LIGHT FIXTURES. CEILING TO BE ARMSTRONG, PRELUDE XL 15/16" GRID W/ 2X2 ULTIMA 1951, ANGLED TEGULAR TILE. INCLUDE ONE (1) LAYER OF BATT INSULATION ABOVE THE WHOLE CEILING. CP4 OPEN EXPOSED CEILING WITH SUSPENDED LIGHT FIXTURES. ADD DUCTWORK AS NEEDED FOR NEW ENCLOSED ROOMS. TOUCH UP PAINT AS NEEDED. CP5 EXISTING DRYWALL BULKHEAD WITH RECESSED DOWNLIGHTS.RECESSED DOWNLIGHT TO BE: CREE, 6" LED RECESSED DOWNLIGHT, LR6C-10L- DIMMABLE, 3500K W/RC6 HOUSING. EXISTING AND RELOCATED EXIT LIGHTING TO BE: LITHONIA LIGHTING, SURFACE MOUNT EDGE LIT EXIT LIGHT, EDG 1R 120/277 ELN 120W OR EQUAL. CLERESTORY PENDANT LIGHT TO BE: IMPACT ARCHITECTURAL LIGHTING, 8" IMAGO.LED W/MATTE WHITE ACRYLIC PARABOLIC OPEN BOTTOM SHADE, WHITE CANOPY, BLACK CORD, AND LED LAMP, P3508.LED-40HI. MOUNT AT 23'-0" TO BOTTOM OF FIXTURE. PENDANT LIGHT FIXTURE TO BE: LAMPS PLUS, RAMONA 32"-W LED PENDANT LIGHT #5W979. EXISTING AND RELOCATED TRACK LIGHT TO BE: CAPRI, SOLIS MONORAIL WITH PIATTO LARGO FIXTURES #TX302-P30-R-A W/ 39 WATT PAR30 LAMPS. EXISTING AND RELOCATED EMERGENCY BATTERY PACK FIXTURE TO BE: PHILIPS MCPHILBEN, #CTX-WHITE W/ 5.4 WATT TUNGSTEN LAMPS. MOUNT AT 12'-0" TO BOTTOM OF FIXTURE. RELOCATE TRACK LIGHTING AS NEEDED FOR NEW WALLS. CP6 REPLACE CLERESTORY PENDANT FIXTURES THAT HAVE NOT BEEN CHANGED. SHOW THIS AS A SEPARATE BUILDING SHELL LINE ITEM. LINEAR PENDANT LIGHT TO BE: METALUMEN, O5K W/CLEAR DUST COVER, PERFORATED CROSS BLADE BAFFLE, OVERLAY OPTIC, AND WHITE FINISH, O5KL35K-8'- CSBO-W-L21-PA-1. EXISTING 2 X 2 LAY-IN GRID SUSPENSION SYSTEM. EXISTING HVAC DUCTWORK. CP7 REPLACE EXITING DOWNLIGHT WITH NEW LED DOWNLIGHTS ON DIMMERS. GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE ALL WIRING FOR COMPUTER NETWORK AND TELEPHONE LINES. VERIFY REQUIREMENTS WITH TENANT'S SERVICE PROVIDER. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, TENANT, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. 5. 6. 4. 3. 2. 1.COPIER/PLOTTER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. EP1 REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. EP2 DUPLEX WALL OUTLET. DEDICATED CIRCUIT OUTLET.D ELECTRICAL/DATA LEGEND: PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +54"HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. EXISTING ELECTRICAL PANEL LOCATION.EP3 POWER POLES ARE NOT TO BE USED. ROUTE ELECTRICAL CONDUIT LATERALLY THROUGH PARTIAL HEIGHT WALL FROM THE DEMISING WALLS. 7. N DENOTES NEW OUTLET LOCATION. EP4 MICROWAVE PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR MICROWAVE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. EP5 PROVIDE NEW ELECTRICAL/DATA SHOWN W/ "N". CABLE TV OUTLET. OPEN CP3 CP6 F GE N NN SCALE: 1/8" = 1'-0" 2 REFLECTED CEILING PLAN A1.2 SCALE: 1/8" = 1'-0" 3 ELECTRICAL/DATA PLAN A1.2SCALE: 1/8" = 1'-0" 1 CLERESTORY REFLECTED CEILING PLAN A1.2 MC BR