HomeMy WebLinkAbout13110024.18CONNECT TO SIDE OF
MAIN. DO NOT CONNECT
FROM TOP OR BOTTOM
CODE APPROVED VACUUM
BREAKER REQUIRED AT ALL
ELEVATED W.H.
CW � •••
HW • • -.�
PRESSURE TEMP. RELIEF '
VALVE DISCHARGE WITHIN WATER
WALL CAVITY TO DISCHARGE HEATER
ABOVE MOP BASIN.
DRAIN VALVE �
STAINLESS STEEL DRAIN
PAN, 1 1/2" DEEP WITH A
1" MINIMUM DRAIN
WATE R H EATE R DETAI L
N.T.S.
INSTALL THERMAL
EXPANSION TANK
NO VALVES OR DEVICES
TO BE INSTALLED
BETWEEN EXPANSION
TANK AND THE WATER
HEATER AS PER CODE.
PROVIDE INTEGRAL
HEAT TRAPS
1" PIPE WASTED WITHIN
WALL CAVITY TO
DISCHARGE ABOVE MOP
SINK
REFER TO ARCH PLANS
FOR WATER HEATER
PLATFORM
TYPICAL VENT THRU ROOF
N.T.S.
CONDENSATE DRAIN
OPEN PIPE TO ATMOSPHERE
PIPE SIZE SAME AS
UNIT CONDENSATE DRAIN
TO APPROVED
RECEPTACLE
A. STATIC PRESSURE IN PAN (INCHES)
B. 0.5 X STATIC PRESSURE IN PAN (INCHES).
NOTE: ALL PIPES FULL SIZE OF UNIT OUTLET
TYPICAL UNIT CONDENSATE PIPING
� N.T.S.
CONNECT TO UNIT GAS
CONTROLS WITH
GROUND JOINT UNION
PROVIDE GROMMET
FOR WATER-TIGHT SEAL
( GAS PIPE SIZE TO
MATCH UNIT
CONNECTION) �--
PLUGGED 1/8"_
NPT TEST GAUGE
CONNECTION
PRESSURE REDUCING VALVE
WITH INTERNAL VENT.
VENT ELBOW DOWN
GROUND JOINT UNION
GAS COCK WITH PLUGGED 1I8"
NPT TEST GAUGE CONNECTION
ROOF TOP UNIT
GAS PIPING - RUN ON ROOF
2"MIN. TYP.
TYP. MECH.
DIRT POCKETJ i PIPE
ROOF
PIPESTAN
9 TYP.
GAS PIPE ADJUSTMENT AT P-2
ROOF OBSTRUCTIONS TYPICAL
NOTE:
CONTRACTOR SHALL VERIFY ALL MECHANICAL
GAS FIRED EQUIPMENT CONNECTION
LOCATIONS IN THE FIELD PRIOR TO INSTALLING
ANY GAS PIPE MAINS OR BRANCHES.
TYPICAL UNIT GAS PIPING CONNECTION
N.T.S.
SEDIMENT
BUCKET
(3) COMPARTMENT SINK DETAIL
N.T.S.
NO SUBSTITUTI4NS
ON ANY FIXTURES.
.�„ �� ,���� ..�..BRANE
)R MATERIAL
FLOOR DRAIN DETAIL
N.T.S.
0
DRAIN FROM
COOLING UNIT CE MAKER
1' MIN AIR GAP
OR AIR BREAK
DEEP SEAL
TRAP
�
� -VENT
I
1
1
� FLOOR DRAIN
� FOR ICE BIN
�
�
�
I
�
TO SAN. WASTE MAIN
ICE MAKER DRAINAGE PIPING DETAIL
N.T.S.
� �
1" MIN.
AIR GAP
NEW FINISH FLOOR MATERIAL
EXISTING SUBFLOOR
FUNNEL 4" HIGH
FLOOR DRAIN WITH
NICKEL BRONZE GRATE
18" RUBBER MEMBRANE
FLOOR DRAIN WITH FUNNEL DETAIL
N.T.S.
SYRUP LINES
3' H�LE—
P L U M B I N G F IXT U RE S C H E D U L E� NOTE: THERE WILL BE ABSOLUTELY NO SUBSTITUTIONS A�LOWED FOR ANY PLUMBING
PRODUCTS AS SPECIFIED. THIS INCLUDES ALL ZURN PRODUCTS.
MARK ITEM MANUFACTURER MODEL NO UTILITIES REMARKS
CW HW W VT TEMP
OICE/BEVERAGE BY VENDOR 1/2" - INTO FS ' '
UNIT
ICE-MAKER HOSHIZAKI KM-280MWH (2)1/2" - - - - WATER COOLED ICE MAKER. PROVIDE W/ HOSHIZAKI
�� B-300PF BIN - SEE 3/P2.
HAND SINK UNIVERSAL EHS-1 1/2" 1/2" 1-1/2" 1-1/2" 110° SEE NOTE 2 FOR THERMOSTATIC MIXING VALVES
19 STAINLESS REQUIREMENTS.
(HS) FAUCET UNIVERSAL CHF-04 GOOSENECK FAUCET.
STAI N LESS
MOP BASIN ZURN Z1996-24 3/4" 3/4" 3" 2" 140°
20 WALL-MOUNT WITH 1/2" IPS FLANGED FEMALE INLET, VACUUM
(MS) FAUCET ZURN Z1996-SF
BREAKER SPOUT, PAIL HOOK, 3/4" HOSE THREAD, LEVER
HANDLES AND ROUGH CHROME FINISH. PROVIDE HOSE BIB
VACUUM BREAKER FOR SPRAYER.
21 3 COMPARTMENT UNIVERSAL #3N1620-2D18-I 1/2" 1/2" INTO ' 140° VERIFY INDIRECT WASTE AND GREASE TRAP - SEE 1/P2.
SINK W/ 2-18" STAINLESS FS
(3CS) DRAIN BOARDS
FAUCET ZURN Z842H1.0002
34 WATER FILTER CUNO #15 1/2"
�1 COMPARTMENT UNIVERSAL #1N1620-RD18 1/2" 1/2" INTO ' 140° VERIFY INDIRECT WASTE
SINK W/ 1-18" STAINLESS FS
(1CS) DRAIN BOARDS
FAUCET ZURN Z842H1-15F
WC-1 HANDICAP ZURN Z5615 - - 4^ 2�� FURNISH WITH ZURN OPEN FRONT SEAT MODEL Z5955SS.
WATER CLOSET FURNISH WITH WALL CARRIER MODEL Z-1204N4.
FLUSH VALVE ZURN Z6000-AV-WS1 1" ' - - FLUSH VALVE MOUNTING HEIGHT AT 26-1/2" AFF
LAV-1 HANDICAP ZURN MODEL Z5354 1/2" 1/2" 1-1/2" 1-1/2" 110° FURNISH W2URN Z81261 FAUCET WITH VANDAL RESISTANT
WALLHUNG AERATOR AND GRID DRAIN. PROVIDE TRU-BRO LAV GUARD.
LAVATORY SEE NOTE 2 FOR THERMOSTATIC MIXING VALVES
REQUIREMENTS
FD-1 FLOOR DRAIN ZURN MODEL ZN415-3NH-6S-P ' - 4^ 2N TYPE "S" STAINER. PROVIDE WITH COMPLETE BODY
ASSEMBLY WITH TRAP PRIMER CONNECTION - SEE 21P2.
FD-2 FLOOR DRAIN ZURN MODEL ZN415-3NH- ' ' 3" 2" FLOOR DRAIN IS TO BE FLUSH WITH FINISH FLOOR.
6S-CONE
GT-1 GREASE ZURN MODEL GT-2700-50 - - 4" 2" 50 G.P.M. FLOW RATE, 100 LBS CAPACITY,
T�P FLUSH-WITH-FLOOR INSTALLATION, 4" TAPPED INLET
AND OUTLET, HEAVY-DUTY NON-SKID GASKETED
COVER SECURED WITH STAINLESS STEEL BOLTS,
FLOW CONTROL VALVE. (3C TO VERIFY IF EXTENSION
KIT WILL BE REQUIRED PRIOR TO INSTALLATION
FCO FLOOR ZURN MODEL ZN1400-3(4)NH-T ' ' - - POLISHED NICKEL BRONZE TOP
CLEANOUT PLUMBER MUST FIELD VERIFY 3" OR 4" CONNECTION
WCO WALL CLEANOUT ZURN MODEL Z-1441-2 - - - - SMOOTH, STAINLESS STEEL ACCESS COVER
FS-1 FLOOR SINK ZURN MODEL Z1901-3NH-2-25 ' ' 3" 2" 12"x12" FLOOR SINK, 3" OUTLET HALF-GRATE, A.R.E.
BUCKET, BOTTOM DOME STRAINER. - TOP OF FLOOR SINK IS
TO BE FLUSH WITH TOP OF FLOOR TILE.
FS-2 FLOOR SINK ZURN MODEL Z1910-3NH-2-25 - - 3" 2" 8"x8" FLOOR SINK, 3" OUTLET HALF-GRATE, A.R.E.
BUCKET, BOTTOM DOME STRAINER. - TOP OF FLOOR SINK IS
TO BE FLUSH WITH TOP OF FLOOR TILE.
TP-1 TRAP PRIMER PPP P1-500 W/ADAPTER 1/2" ' 3" 2"
BFP-1 BACKFLOW WATTS 007 1" - INTO - VERIFY BFP TYPE AND INS7ALLATION WITH LOCAL AHJ
PREVENTER FD
BFP-2 BACKFLOW WATTS 9BD 1/2" - INTO - VERIFY BFP TYPE AND INSTALLATION WITH LOCAL AHJ
PREVENTER FD
ELECTRIC WATER HEATER SCHEDULE
MANUFACTURER STORAGE EWT LWT REC. ELECTRIC ELEMENT
MARK AND MODEL NO. CAPACITY DEG. DEG. GPH
(GALLONS) F F KW VOLT PH STAGES REMARKS
WH-1 A.O.SMITH 50 40 140 74 18 208 3 1 (1) 18 KW PROVIDE
DVE �2 INTEGRAL HEAT TRAPS - SEE 5/P-2
6' PVC CAP O
90• ANGLE
18 SUBFLD�R
6' PVC CHASE
FINISHED
FLOOR
FIGURE 1.0 FILL IN H�LE WITH — — — — — — — — — — — —
F�AM AND CAULKING AR�UND
SYRUP LINES SEE FIGURE 1,0
S�DA CHASE TERMINATION DETAIL
� Q N.T.S.
C��
NOTE:
1. SPACE BLOCKING STANDS AT
6'-0" INTERVALS ON ROOF.
2. FOLD UP END OF SLIP SHEET
AND NAIL TO BLOCK
CONDENSATE PIPE
METAL STRAP WITH 1/4"0 x
2" LAG EACH SIDE, ALLOW
FOR MOVEMENT
4x6 "WOLMANIZED"
BLOCKING - MASTIC TO
ADDITIONAL ROOFING
SHEET
CONDENSATE SUPPORT SIMILAR
N.T.S.
16
PLUMBING LEGEND
— —SAN— — SAN— — SANITARY
— —GW— —GVIN— — GREASE WASTE
------------- PLUMBINGVENT
CW — CW COLD WATER
HW — — HW HOT WATER
GAS GAS GAS PIPING
�I FLOOR DRAIN
�O FLOOR CLEANOUT
I� WALL CLEANOUT
� FLOOR SINK
Q HUB DRAIN
�p� BALL VALVE
� TEMPERING VALVE
� BACKFLOW PREVENTER
NOTES
1. ALL PLUMBING FIXTURES TO BE FULLY ACCESSIBLE TO INDIVIDUALS WITH DISABILITIES ACT OF
1990. FIXTURES AND THEIR INSTALLATION SHALL ALSO COMPLY WITH AMERICAN NATIONAL
STANDARDS INSTITUTE (ANSI) PUBLICATION A117.1 - PROVIDING ACCESSIBILITY AND USABILITY
FOR PHYSICALLY HANDICAPPED PEOPLE AND/OR GOVERNING CODES. - ALL PLUMBING FIXTURES
EQUIPMENT, TRIM, & FITTINGS SHALL COMPLY WITH CITY REQUIREMENTS, AND FEDERAL
REGULATIONS AND CODES, INCLUDING, BUT NOT LIMITED TO, WATER AND ENERGY
CONSERVATION CODES. THE SCHEDULED AND/OR SPECIFIED PLUMBING FIXTURES AND
EQUIPMENT REPRESENT THE MINIMUM CRITERIA AND SHALL BE THE BASIS FOR THE
CONTRACTOR'S BASE BID. IF THE SCHEDULED OR SPECIFIED FIXTURES OR EQUIPMENT DO NOT
COMPLY WITH GOVERNING CODES OR REGULATIONS IN ALL RESPECTS, THE CONTRACTOR SHALL
PROVIDE AN ALTERNATE BID FOR COMPLYING FIXTURES, EQUIPMENT, TRIM, OR FITTINGS. THE
ABSENCE OF AN ALTERNATE BID SHALL BE CONSTRUED TO MEAN THAT THE CONTRACTOR'S BID
INCLUDES ALL COSTS NECESSARY TO MEET ALL REGULATIONS 8� CODES.
2. PROVIDE THERMOSTATIC MIXING VALVE (� AT ALL LAVATORIES AND HAND SINKS. PROVIDE
ZURN TMV-1, 1 TO 15 GPM, NOT TO EXCEED 3 PSI, W/ UNION STOP CHECK INLETS, AND
REMOVABLE STAINLESS STEEL STRAINERS, DIAL THERMOMETER AND DISCHARGE VALVE.
SUPPLIES 110^F.
3. ALL ROOF PENETRATIONS SHALL BE APPROVED BY LANDLORD AND DONE IN ACCORDANCE WITH
ROOF MANUFACTURERS RECOMMENDATIONS SO AS NOT TO VOID THE WARRANTY.
PLUMBING FIXTURE SUPPLIER
KEC DESIGN
CONTACT: DAN PROCTOR
301 MERCURY DRIVE
SUITE 1
CHAMPAIGN, IL 61822
PHONE: 217.356.1640
FAX: 217.356.1661
EMAIL: danproctor@kecdesign.net
v �
13-892-491
� I'
1V��Y j��`�'�A1i �
�1 S ;
I
Sinre l433
�
Q� AM T�SANDN CB�a � �.
��
I
�.
�.
��
I
�
�.
t� .
�
�
�
1 �.
:,: :t:
' ." , ��'"`'. �-
;;: � � �`„ S�;` `,• .
,�..'w • . . . ' � ;
. �', �^:l:V ; .z•�,. ��� l
,.~;%;�, ,4,.,\��, �� .
-:�_,;��/y�;�:� ..
�� zs �. ,�..... ���
=� .� �,, , , ,�" >. ,.:k . ...
f, :� . r% .
ii �.<; " ...,....:...•• `l'�' ,
,i. ,J' '� ^ S � i`a� `��
'� � ��`�:�`;�� �
,,...;4; % ;
1 �
� �' �
N �
N
� C ' �
� •
� �m �
� �
m�
>�
N� -
� � _.
J j(
N � �� '
a �°'
� �
m� ,
.� o
� N �
N � �
� '� t
O ��
� . ; L�
a ��� �
N
N �
W N
� � � , . .
� O �
0
��
� --
��.
� a '
W � r
� �
a � � � ��
��� � � .
� ~� pa, A
� � � O
A � �
� I
�
� Wm� �:�
a° � � ��� .
��.
� z�
� �aw ,
� ��� f.
., E„
��� � .
w
W�UV] L.
� � W �
�� � ti
� � E � �..
� � �
O ��.. f�
V � ' ��
r
1 DATE: 8��13 f
i.
DATE REVISED � L�
.
1 SHEET TITLE F ��
PLUMBING LEGENDS, 4
SCHEDULES AND DETAILS �
. ,L.t,
1 SHEET NUMBER
P-2
��
,.�.
� �