HomeMy WebLinkAbout13110024.23� _ LIGHTING FI�CTURE SCHEDULE FIXTURE KEC MANUFACTURER'S MOUNTING �,PE DESCRIPTION STOCK # CAT. NO. NPE LAMP OLTAG BALLAST TYPE LENS MOUNTING HEIGHT REMARKS 2'X4' LAY-IN (3) LAMP RECESSED LIGHTOLIER # (3) 25W 120 ELECTRONIC ACRYLIC RECESSED CEILING A-1 FLUORESCENT FIXTURE WITH ONE KLITE #1481 XT2GVA330-12003 TS BALLAST B-3 3' ULTRA SLIMLITE FLUORESCENT KLITE #1803 LIGHTOLIER # 18W 120 4" SGtUARE ACRYLIC SUSPENDED MOUNT AT 12'�' A.F.F. E. C SHALL VERIFY EXACT MOUNTING HGT. USL3-18-M-S-1�-P A REMOTE BALLAS BELOW EXPOSED SPIRAL DUCTWORK LIGHTOLIER # 18W 4" SQUARE ACRYLIC SUSPENDED MOUNT AT 12'�' AF.F. E. C SHALL VERIFY EXACT MOUNTING HGT. B-4 4' ULTRA SLIMLITE FLUORESCENT KLITE #1804 USL4-18-M-S-1-S-P-A 120 REMOTE BALLAS BELOW EXPOSED SPIRAL DUCTWORK LIGHTOLIER # 2 28W 120 - - - E. C SHALL VERIFY EXACT MOUNTING HGT. C NARROW STRIP FLOURECENT KLITE #0046 SV4S228UNVPG T5 LAMPS MOUNT IS SOFFIT COVE BELOW EXPOSED SPIRAL DUCTWORK (QUANTITY 3) LINEAR FLUORESCENT FIXTURE KLITE #4110 STICK T5 180° DIFFUSER (1) 54W T5 120 ELECTRONIC - SURFACE/ MOUNT AT 10'-0' A.F.F. SUSPEND LIGHT FIXTURE � ST54154UE.4111SAC/SPF PENDANT E DELRAY LIGHITNG MR-16 12V -- OPEN DIRECT PROVIDE LED DRIVER. INSTALL ABOVE MINI RED PENDANT KLITE #4111 LED MOUNTED MOUNT AT 6'-0' A.F.F. COOLERS � X6300SR/BMR16LED F WALL MOUNTED INCANDESCENT FIXTURE RAB VX200DG (1) 60W 120 ELECTRONIC NATURAL �. ��� WALL � KLITE #0158 2pp SERIES WITH CAGE INISHED LOOR EMERGENCY EXIT SIGN WITH PHILIPS # LED 120/ - CLEAR ACRYLIC SURFACE UNIVERSAL H BATTERY BACK-UP KLITE #0100 VCRWLRC 6V DC W/RED LETTERS EMERGENCY LIGHTING THERMOPLASTIC PHILIPS (2) 5.4W 120/ - - SURFACE UNIVERSAL 1-2 18W UNIT WITH BATTERY BACK-UP KLITE #0113 CHLORIDE # TUNGSTEN 6V DC � VU6 I-3 COMBO LED EXIT SIGN AND 2-HEAD PHILIPS (2) 5.4W 120/ - CLEAR ACRYLIC SURFACE UNIVERSAL FIXTURE TO BE USED WITH REMOTE I-5 �EMERGENCY LIGHT. THERMOPLASTIC KLITE #0114 TUNGSTEN 6V DC W/RED LETTERS FIXTURE 24W BATTERY BACK-UP UNIT W/REMOTE CHLORIDE # CAPACITY VCRW I-5 REMOTE LAMP HEADS 8� MOUNTING LIGHTOLIER # �2) 9W 6V DC INVERTER GLASS LENS SURFACE WALL PROVIDE EMERGENCY BATTERY BACKUP y PLATE CRMP2 (PLATE) IT86 REQUIREMENTSY EGRESS V�� IT86 (HEAD) J RECESSED INCANDESCENT DOWNLIGHT LIGHTOLIER# (1) 32W 120 - FRESNEL RECESSED CEILING O WITH 6-3/4" APERTURE 1101 F2642 W/1101 HCDF �ENSLITE FRAME KIT CF 60" CEILING FAN KLITE #3150 HAIKU - 120 - - PENDANT MOUNT AT 7-0' FROM E.C. MUST FIELD VERIFY THE LENGTH OF � K3150-XO-07/20 CEILING DOWN ROD REQUIRED TO EXTEND FROM THE CEILING FAN TO THE CEILING HT. ABOVE NOTES: 1. ALL LIGHT FIXTURES, LAMPS AND CEILING FANS ARE SUPPLIED BY OWNER AND INSTALLED BY ELECTRICAL CONTRACTOR. NO SUBSTITUTI ONS ON ANY F IXTU RES. CONTACT KEC DESIGN, ATTENTION DAN PROCTOR OR JEREMY FELLERS AT 301 MERCURY DRIVE, #10, CHAMPAIGN, IL. 61822. PH: (217) 356-1640. PENDANT TO BE CENTERED OVER ALL TABL ES/BOOTH S/COU NTERS CONTROLLED CIRCUITS TO EXTERIOR SIGNAGE AND/OR EXTERIOR LIGHTING. SEE FLOOR PLAN. �' LL Q N � C7 Z W � J Q LIGHTING PLACEMENT DETAIL 1 /4" = 1'-0" CIRCUITS FROM LIGHTING PANEL LIGHTING CONTROL PANELS (TIME CLOCK) WITH 20 AMP NORMAL OPEN ELECTRICAL HELD RELAYS. ELECTRICAL CONTRACTOR TO VERIFY NUMBER OF RELAYS REQUIRED LIGHTING CONTR4L RISER NO SGLLE � SUPPORT WIRES MAY BE INSTALLED ALONG LENGTH OF LINEAR FIXTURES TO WORK AROUND POSSIBLE OVERHEAD MECHANICALS LL�L Q 0 O r FIXTURE TYPE FIXTURE COUNT A-1 12 B-3 3 B-4 2 C 3 D 8 E 9 F 6 J 7 G ERAL NOTES= A. INSTALL INTERIOR LIGHTING FlXTURES AT LOCATIONS AS INDICATED, IN ACCORDANCE WITH FIXTURE MANUFACTURER'S WRITTEN INSTRUCTIONS, APPLICABLE REQUIREMENTS OF NEC� NECA'S "STANDARD OF INSTALLATION", NEMA STANDARDS� AND WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE THAT LIGHTING FIXTURES FULFILL REQUIREMENTS. B. FASTEN LIGHTING FlXTURES SECURELY TO STRUCTURAL SUPPORTS; AND ENSURE THAT FIXTURES ARE PLUMB AND LEVEL. C. FLUORESCENT FIXTURES INSTALLED IN LAY-IN CEILINGS SHALL BE SUPPORTED BY ADDITIONAL WIRE SUPPORT AT TWO CORNERS. ATTACHED TO CEILING GRID. AND ANCHORED TO STRUCTURAL MEMBER. THIS ADDITIONAL WIRE SUPPORT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR AND IS NOT CONSIDERED PART OF GENERAL GRID LAYOUT. D. PROVIDE EQUIPMENT GROUNDING CONNECTIONS FOR INTERIOR LIGHTING FIXTURES AS INDICATED. TIGHTEN CONNECTION TO COMPLY WITH TIGHTENING TORQUES SPECIFIED IN UL STD 486A TO ASSURE PERMANENT AND EFFECTIVE GROUNDS. E. ALL EXIT, EMERGENCY AND NIGHT LIGHT FIXTURES SHALL BE PLACED ON THE 'UNSWITCHED' SIDE OF BRANCH CIRCUIT WIRING, TYPICAL F. ALL TRACK-SUPPORTING UNISTRUT SHOULD BE RUN PARALLEL WITH THE TRACKS. G. ANY EXPOSED CONDUIT IN DINING ROOM MUST BE RIGID CONDUIT AND RUN TIGHT TO THE DECK. ONLY EXCEPTION IS MC CABLE MAY USED WHEN CONNECIING TRACK LIGHTING TO THE JUNCTION BOX. NO MC CABLE CAN BE RUN LONGER THE 12" WHEN RUNNING HORIZONTALLY ON THE DECK TO THE JUNCTION BOX. ANY PRE-EXISTING MC CABLE EXPOSED IN THE SPACE MUST BE REPLACED WITH RIGID CONDUIT. H. MC CABLE USED TO POWER THE TRACK UGHTING IS TO BE INSTALLED T1GHT TO THE THREADED RODS TO THE LIVE END OF THE TRACK. I. CONDUIT MUST NOT BE MOUNTED ON WALL SURFACES ANYNMERE IN EXPOSED AREAS. ALL CONDUIT SERVING DEVICES IN EXTERIOR WALLS MUST BE CONCEALED WITHIN WALLS. O LIGHTING KEY NOTES� 1. CONNECT EXHAUST FAN TO LOCAL 120V LIGHTING CIRCUIT AND SWITCH WITH SAME. 2. VERIFY WITH OWNER EXACT LOCATION AND MOUNTING HEIGHT OF EMERGENCY EGRESS LIGHTING AND SIGNAGE OUTLETS ABOVE DOOR AND PLATE GLASS. 3. JUNCTION BOX FOR CONNECTION TO WALK-IN LIGHTS AND DOOR HEATERS. 4. NOT USED. 5. JUNCTION BOX MOUNTED IN CEILING FOR CONNECTION TO CEILING FAN. COORDINATE EXACT �OCATION WITH OWNER PRIOR TO ROUGH-IN. 6. ELECTRICAL TIME CLOCKS MOUNTED NEAR DESK FOR LIGHTS AND SIGNAGE. SEE LIGHTING CONTROL RISER DIAGRAM THIS SHEET. MOUNT TIGHT TO DROP CEILING. 7. INDICATES 120/208 3 PHASE, 4 WIRE RECESSED PANEL. 8. ELEMENTAL LED 12V LED DRIVER LOCATED ABOVE COOLERS. VERIFY EXACT LOCATION. EL-12VINDRVR (600W) 9. NOT USED. 10. PENDANT MOUNTED LIGHT FIXTURE. REFER TO LIGHTING PLACEMENT DEfAIL THIS SHEET. (NPICAL) 11. STACK SWITCHES TO AVOID SHELVING/EQUIPMENT. VERIFY EXACT LOCATION WITH OWNER PRIOR TO ROUGH-IN. 12. EMERGENCY EGRESS LIGHTING TO BE UNSWITCHED. CONTRACTOR TO POWER FROM EM CIRCUIT B-13. I I -----------------------� r----------------------------------------- ;� ;; '__"'____'____'_ '_ .__�_'_'_'_'_' '_ '____' iI ��OOR P LAN �I GH TI N G SCALE 1 /4" = 1'-0" `� xoR� � I13-892-491 � ���M'Y 1°N�'s SNce i983 °ptr��ar'saxvwlcass ;;: . ,;�,, : � , �, . . i-j � . ''�. .4,�,(�`'_`'C4'�' ���: i,^/�c_ ;�� � , - =r, , ✓ -.��. .:ri '`/� . � �.- < � =, '�`�.CJ`?"�', y' \�`: :, ,� �;. � L�� ,�� �� ML ,, ;,;� W t �,�:t::;�,,. � � � W a � �� � ^ �"� � � �A oo� a� � � � � �� �rT, � � w H � M", W � � � DATE: 8/'?3/'13 ' DATE REVISED ' � M � N � N O � � Y m w m � = T N � � � � J j( • � � N � O � � N � •� o � N N� � O � � W � �� O N N � W N � � �f1 O O �A � 0 � � z c� � � � a w a A � o � � � �m� d, d' `�z� ��� w a :°�F w r" �Uf/1 W o �a ti o �� E � � �a I� io i� 1 SHEET TITLE FLOOR PLAN, SCHEDULES, AND DETAILS - ELECTRICAL 1 SHEET NUMBER E 2 2 OF: 3