HomeMy WebLinkAbout13110024.26, � � 0 M1 �2' X 4' LAY-IN FLUORESCENT FIXTURE� LETfER REFERS TO FIXTURE TYPE. REFER TO LIGHT FIXTURE SCHEDULE. K � 1� X 4' SURFACE MOUNT FIXTURE. "NL" - INDICATES LIGHT FIXTURE TO BE ON NIGHT LIGHT CIRCUIT. NL �TRACK WITH TRACK MOUNTED FLUORESCENT LIGHT FIXTURE. LENGTHS AS INDICATED ON PIANS. o-c� TRACK WITH TRACK MOUNTED FLUORESCENT LYTEFLOOD. E_�� MINI-BLUE PENDANT FIXTURE �..pF WALL MOUNTED FLUORESCENT FIXTURE G-c� CLASSY MENUBOARD FIXTURE �-� � EGRESS FIXTURE �X WALL OR CEILING MOUNTED EXIT SIGN. �� WALL MOUNTED EMERGENCY LIGHT. � SINGLE POLE SWITCH. �M 1 POLE, 20 AMP, 125 VOLT MOTOR RATED TOGGLE SWITCH. JO JUNCTION BOX. � 20 AMP, 125V DUPLEX RECEPTACLE. MOUNT AT 18" A.F.F. TO CENTER. UNLESS NOTED OTHERWISE. �wP DUPLEX RECEPTACLE IN WEATHERPROOF BOX. ��� DUPLEX RECEPTACLE WITH ISOLATED GROUND. �c� DUPLEX RECEPTACLE WITH GROUND FAULT PROTECTION. �AC DUPLEX RECEPTACLE INSTALLED ABOVE COUNTER. � QUADRAPLEX RECEPTACLE. � LIGHTING AND/OR APPLIANCE PANELBOARD - SURFACE MOUNTED. � EQUIPMENT DISCONNECT SWITCH. ALL FUSIBLE SWITCHES SHALL BE PROVIDED WITH FUSES SIZED PER EQUIPMENT NAMEPLATE. � MOTOR CONNECTION. I TELEPHONE/DATA OUTLEf S p - 120VAC FIRE ALARM DUCT MOUNTED PHOTO ELECTRIC SMOKE DEfECTOR -INTERLOCK WITH HVAC SUPPLY AIR FAN AS REQUIRED FOR FAN SHUTDOWN UPON DEVICE ACTIVATION. CONDUIT RUN UNDERSIAB. CONDUIT RUN ABOVE CEILING OR CONCEALED IN WALLS. CONDUIT BARS INDICATE CONDUCTORS PHASE (HOT) NEUTRAL (GROUND) EQUIPMENT GROUNDING � EQUIPMENT DISCONNECT SWITCH. PROVIDE SWITCH AS DESIGNATED: 2/30/240/1/F � FUSIBLE (F) OR NON-FUSED (NF) NEMA ENCLOSURE RATING AMPACITY N0. OF POLES ALL FUSIBLE SWITCHES SHALL BE PR❑VIDED WITH FUSES SIZED PER EQUIPMENT NAMEPLATE, C❑NTRACTOR SHALL MAKE FINAL ELECTRICAL C❑NNECTI❑N T❑ EQUIPMENT WITH SEAL-TITE, ELECTRICAL SYMBOL NOTES� NOTE: 1. RECEPTACLES. SWRCHES, AND COVER PLATES IN DINING ROOM ARE TO MATCH THE SURROUNDING WALL FINISHES. 2. ALL RECEPTACLES AND SWITCHES IN PREP AREA AND RESTROOMS NEED TO BE WHITE. 3. ALL COVER PLATES IN THE PREP AREA AND RESTROOMS NEED TO BE STAINLESS STEEL ELECTRICAL DEMOLITION NOTES� 1. ELECTRICJIL CONTRAiCfOR SHALL REVIEW THE ARCHITECTURAL DRAWINGS TO VERIFY THE EXTENT OF THE DEwI0LIT10N AND REMODELING WORK. ELECTRICAL CONTRACTOR SHALL SURVtY D(15T1NG SITE AND DETERMINE EXTENT OF NECESSARY REALLOCATIONS. REMOVALS AND REPAIRS TO D(ISTING ELECTRICAL WORK REQUIRED TO AVOID CONFLICTS WITH NEW CONSTRUCTION TO MEET MINIMUM LOCAL AND STATE CODE REQUIREMENTS. ALL ELECTRICAL OUTLEIS. FlXTURES RECEPTACLES, DEVICES� ETC. NOT BEING REUSED SHALL BE REMO'VED AND OUTLETS ARE TO BE CAPPED ACCORDING TO NOTE #7: CONDUIT TO BE ABANDONED IN PLA�CE AND ALL WIRING SHALL BE DISCONNECTED AT SOURCE AND REMOVED COMPLETELY. NO D(ISTING JUNCTIONS OR CONDUIT COVERS SHALL BE BURIED IN NEW WALLS. ELECTRIGIL CONTRACTOR TO RELOCATE SAME AS REQUIRED. A FIELD SURVEY VERIFlCATION IS I�IIWDATORY IN ORDER TO SUBMff AN ELECTRICAL BID, FAILURE TO DO SO SHALL NOT REIJEbE THIS CONTRACTOR FROM PERFORMING THE WORK OF THIS CONTR/4CT. 2. D(ISTING CONDUfT GW BE REUSED PROVIDING IT IS CHECKED FOR CONTINUITY OF GROUND, BLONM FREE OF DEBRIS, AND DOES NOT INTERFERE WITH NEW CONSTRUCTION. 3. ALL CUTTING AND PATCHING OF EXISTING PLASTER, DRYWALL, WOOD, CONCRETE ETC., FOR THE ELECTRICAL INSTALLATION IS BY THE ELECTRICAL CONTRACTOR. BEFORE ANY CUTTING, APPROVAL FROM THE ARCHITECT IS NECESSARY. CARE IS TO BE TAKEN AND ALL CUTS OR CORING ARE TO BE SQUARE - NO CHOPPING! 4. ALL D(ISTING EQUIPMENT IS TO REMAIN OPERATIONAL DURING THE CONSTRUCTION PERIOD. ANY TEMPORAR'Y WIRING OR REROUTING OF CIRCUITRY TO ACHIEVE THIS IS BY THE ELECTRICa4L CONTRAiCTOR. SHUTDOWN OF EXISTING SERVICES SHALL ONLY BE PERMITTED UPON WRITiEN APPRO'VAL FROM THE OWNER AND THEN ONLY FOR THE DATE AND DURATION H�GREED UPON. INCLUDE ALL PREMIUM TIME CHARGES IN THE BASE BID. 5. UNLESS INDIGITED OTHERWISE. ALL LIGHTING FlXTURES, ELECTRICAL DEVICES AND ALL REMS OF THE D(ISTING FNAiC SYSTEM SHALL REMAIN UNLESS IN CONFLICT WITH REMODEUNG. 6. ALL LJGHTING FlXTURES REMONED AND NOT REUSED SHALL BECOME THE PROPERTY OF THE OWNER. IF THE OWNER ELECTS NOT TO RETAIN FlXTURES� ELECTRICAL CONTRACTOR SHALL REMONE FlXTURES FROM JOB SITE AND DISPOSE OF PROPERLY. 7. ELECTRIGL CONTRA�fOR SF�11LL BLANK WITH PROPER FINISH PLATE IF FLUSH OUTLEf D(ISTS FOR ITEti1S TO BE REMOVED. ANY INTERRUPTION OF CIRCUITING TO ARF�4.S NOT BEING REMODELED SFUILL BE INTERCEPTED AT A LOCATION THAT DOES NOT INTERFERE WITH NEW CONSTRUCTION. HOMERUN CIRCUITING FOR THESE INTERRUPTED CIRCUITS IS TO BE NEW WIRING. AFTER REMOVAL, ALL CONTINUITI( IS TO BE CHECKED FOR ALL OURETS IN THE AREAS NOT BEING REMODELED TO INSURE PROPER FUNCTIONING. 8. ELECTRICAL COM'RA�CTOR SHALL COORDINATE WITH GENERAL CONTRACTOR FOR REMOVAL OR RELOCATION OF DqST1NG ELECTRICAL EQUIPMENT (FOR EXAMPLE: LIGHTING FIXTURES, RECEPTACLES. DEVICES. CONDUIT AND WIRING) THAT WILL BE ABANDONED OR IN CONFLICT WITH NEW CONSTRUCTION. NO ADDITIONAL COST WILL BE PERMITTED. REFER TO ARCHITECTURAL DRAWINGS FOR EXTENT OF REMODELING. 9. ALL CONDUR. DEVICES. FlXTURES, ETC. SHOWN IN THE DEMOLITION DRAWINGS TO BE REMONED OR RELOCATED ARE ONLY FOR THE CONVENIENCE OF THE BIDDERS. ELECTRICAL CONTRA�fOR SHALL FIELD VERIFY ALL ITEMS PRIOR TO SUBMITTING A BID. 10. NEW WORK AND EOUIPMENT IN THE EXISTING BUILDING HAS BEEN INDICATED ON THE DRAWINGS AS ACCURATELY AS POSSIBLE. EACH CONTRACTOR SHALL ADJUST HIS WORK AS REQUIRED TO AVOID EXISTING DUCTS, PIPES. CONDUITS AND BEAM NOT SHOWN ON PLANS. FJ�CH CONTRI4CTOR SHALL ADAPT HIS WORK TO MEEf ALL ACTUAL CONDITIONS ON THE IXISTING PREMISES. MECH. MAT'L & PROCEDURE NOTES: DUCTNrORK: 1. ALL DUCTW�ORK SHALL BE FABRICATED FROM GALVANIZED METAL IN ACCORDANCE WI1H SWiACNA STANDARDS FOR LOW AND MEDIUM PRESSURE DUCT CONSTRUCTION. DUCT SIZES SHOWN INDICATE INSIDE DIMENSIONS. 2 ALL DUCTWORK ACCESS DOORS SHALL BE OF SUFFICIENT SIZE TO PERMIT EASY ACCESS AND THE SERVICING OF DAMPERS, CONTROLS. DEVICES. ETC. ACCESS DOORS SHALL BE VENTLOK COMPLETE WITH �50 HINGES NATH BRASS PINS� #100 LATCHES� DOOR GASKETS� ETC. DOORS LOCATED IN INSULATED DUCTWORK SHALL HAVE 1/2" THICK FlBERGLASS INSUU110N BETWEEN TWO THICKNESS OF SHEET METAL 3. DUCTW'ORK SHALL COIdPLY WITH ALL LOCAL AND STATE REGULATIONS REGARDING FlRE STOPPING. PROOFlNG AND DAMPERING. ACCESS DOORS OF SUFFICIENT SIZE FOR EASY ACCESS AND SERVICING SHALL 8E PROVIDED AT ALL FIRE DAMPERS. 4. AIR VELOCITY IN LOW PRESSURE MAIN SUPPLY TRUNKS SHALL NOT EXCEED 1500 FPM.IN SUPPLY BRANCHES VELOCITY SHALL NOT EXCEED 1200 FPwI� AND IN RETURN AIR DUCT VELOCITY SHALL NOT EXCEED 1200 FPwI. 5. MECHANICAL CONTRACTOR TO CORDINATE DUCT INSTALLATION WITH BRIqC/T1LE INSTALLERS TO ENSURE PROPER CLEARANCES. DUCT INSULATION: 1. ALL SUPPLY DUCTMI�ORK FROM HEAl1NG/COOLING UNITS SHALL BE UNED NATH 1-1/2 LB DENSITY� 1/2' THICK FlBERGLASS DUCT LJNER. DUCT LINING AND ADHESIVE SHALL BE IN CONFORMANCE WITH NFPA N0. 90A STANDARDS. 2 ALL RElURN DUCTWORK WITHIN 10'-0° OF HEATING/COOLING UNITS SHALL BE UNED WITH 1-1/2 LB DENSITY� 1/2" THICK FlBERGLASS DUCT LINER. DUCT UNING AND ADHESIVE SHALL BE IN CONFORMANCE YNTH NFPA N0. 90A STANDARDS. 3. ALL EXHAUST DUCTWORK ON THE SUC110N SIDE OF EXHAUST FANS SHALL BE LJNED YNTH 1-1 /2 LB DENSITY, 1/2" THICK FlBERGLASS DUCT IJNER. FOR A MINIMUM DISTANCE OF 10'-0". 4. ALL DUCT INSUUTION SHALL HAVE A FLAME SPREAD RAl1NG OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED RAl1NG OF NOT MORE THAN 50. DUCT SMOKE DElECTOR: 1. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN SUPPLY AND RETURN DUCTS ON ALL A/C EQUIPMENT 2000 CFM OR LARGER. ELECTRICAL CONTRACTOR TO SUPPLY AND WIRE DETECTOR. MECHANICAL CONTRACTOR TO DUCT MOUNT DElECTOR. ELECTRICAL AND MECHANICAL CONTRACTORS TO COORDINATE SIZES AND TYPES FOR INSTALLATION. GAS PIPING: 1. THIS CONTRACTOR SHALL CONTACT LOCAL GAS COMPANY TO COORDINATE: NEW GAS LOAD� METER LOCATION, AND PRESSURE REGULATOR ASSEMBLY. 2 GAS PIPING SHALL 8E SCHED. 40 BLACK CARBON STEEL, WITH MALLEABLE IRON 150 LB. FITTINGS. GAS PIPING LARGER THAN 2" SHALL BE WELDED. PIPING UNDER 2' SHALL BE THREADED CONNECTIONS. 3. GAS COCKS (CRANE �254 WITH CHECK OR EQUAL)� AND DIRT LEGS (MIN. 6') SHALL BE INSTALLED IN THE PIPING TO EACH PIECE OF GAS FlRED EQUIPbiENT. 4. BEFORE FlNAL EQUIPMENT CONNECTIONS ARE MADE, PNEUMATICALLY TEST GAS PIPING AT 15 PSIG AIR PRESSURE. THE PRESSURE TEST SHALL BE DEEMED ACCEPTABLE IF THE PIPING SYSTEM HOLDS THE PRESSURE FOR FOUR (4) HOURS. TESTING SHALL BE WITNESSED BY OWNER. MECHANICAL EQUIPMENT NOTES: 1. ALL EQUIPMENT/DEVICES SHALL BE NEW AND OF FIRST RATE QUALITY (UNLESS OTHERWISE SPECIFIED) AND IS TO BEAR THE APPROPRIATE AGA, CSA OR UL APPROVED LABELS, LISTiNGS, AND CERTIFlCATIONS FOR THE SPECIFIC DESIGN PURPOSE. 2. ALL EQUIPMENT SOUND LEVELS SHALL NOT EXCEED 50 DB AT PROPERTY LINE. 3. ALL INTERCONNECTING WIRING AT UNIT SHALL BE FACTORY PREWIRED AND REQUIRE ONLY ONE (1) POWER CONNECTION TO THE UNIT BY THE ELECTRICAL CONTRACTOR. DISCONNECT SWITCH SHALL BE BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. 4. ELECTRICAL CONTRACTOR SHALL FURNISH COMBINATION MAGNETIC STARTER-DISCONNECT SWITCHES AS REQUIRED (WEATHERPROOF FOR EQUIPMENT LOCATED OUTSIDE OF BUILDING). THE ELECTRICAL CONTRACTOR WILL INSTALL. 5. SUBMIT EIGHT (8) COPIES OF EACH CATALOG CUT, FOR THE EQUIPMENT SPECIFIED, TO THE ARCHITECT/ENGINEER FOR APPROVAL PRIOR TO THE BEGINNING OF CONSTRUC110N. THIS CONTRACTOR SHALL ALSO ASSEMBLE PRINTED INSTRUC110NS FOR THE OPERATION AND MAINTENANCE OF EACH ITEM INSTALLED AND BIND TOGETHER WITH EQUIPMENT CUTS AND CONTROL WIRING DIAGRAMS. SUBMIT EIGHT (8) COPIES TO THE OWNER/ARCHITECT/ENGINEER. 6. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL STRUCTURAL STEEL MEMBERS, SLEEVES, AND SHIMS REQUIRED TO LEVEL AND SUPPORT EQUIPMENT, ROOF CURBS AND EQUIPMENT SUPPORTS. MECHANICAL SYMBOL LIST SYMBOL DESCRIPTION CFM CUBIC FEET OF AIR PER MINUTE DIFF DIFFUSER EA EACH EF-# EXHAUST FAN ESP EXTERNAL STAl1C PRESSURE FBO FURNISHED BY OTHERS GR GRILLE MVD MANUAL VOLUME DAMPER NK NECK OAI OUTSIDE AIR INTAKE RTU-� ROOFTOP UNIT U-CUT UNDERCUT DOOR � SUPPLY DUCT UP THRU FLOOR/ ROOF � RETURN DUCT UP THRU FLOOR/ ROOF i MANUAL VOLUME DAMPER � THERMOSTAT EQUIPMENT TAG GAS GAS PIPING -i�'�r- GAS COCK REDUCER PLUMBING MAT'L & PROC. NQTES MATERIALS: 1. ALL MATERIALS SHALL BE NEW� OF FlRST QUALITY AND UL LJSTED FOR THE SPECIFIC DESIGN PURPOSE. 2. SANITARY, VENT AND STORM LINES SHALL BE CAST IRON AND AS PERMITTED BY THE LOCAL AND STATE CODE AUTHORITiES. PVC NOT PERMITTED WHERE DISCHARGE EXCEEDS 90'F 3. ALL WATER AND WASTE PIPING TO BE RUN ON WARM SIDE OF INSULAl10N. 4. DOMESIIC SUPPLY PIPING LOCATED ABOVE THE FlNISHED FLOOR SHALL BE TYPE "L" COPPER. UNDERGROUND DOMESTIC SUPPLY PIPING SHALL BE TYPE '�K" COPPER. 5. THREADED FlTTINGS ON GALVANIZED STEEL PIPING SHALL BE 150� CLASS GALVANIZED MALLEABLE IRON FlTTING CONFORMING TO ASTM A-197 SPECIFlC T10N. 6. FURNISH AND INSTALL UNIONS WHERE INDICATED OR NECESSARY FOR REPAIR OR SERVICE. UNIONS 2" AND SMALLER SHALL BE STANDARD GROUND JOINT BRASS TO IRON SEAT, MALLEABLE IRON, SCREWED. UNIONS 2-1 /2" AND LARGER SHALL 8E STANDARD CAST IRON FLANGED UNIONS 125� CLASS. 7. VALVES SHALL BE MANUFACTURED BY CRANE� STOCKHAM. 8. DOMESTIC HOT WATER SUPPLY PIPING SHALL BE INSULATED WITH ONE OF THE FOLLOWING: (INSTALL AS RECOMMENDED BY MANUFACTURER). A. 1" THICK PREFORMED FlBERGLASS WITH "K" FACTOR OF 0.23 MAXIMUM AT 75'F. MEAN TEMPERATURE. JACKET TO BE FACTORY APPLIED KRAFT PAPER WITH VAPOR BARRIER. B. 1" THICK MOLDED RIGID PHENOLIC FOAM WITH "K'� FACTOR OF 0.23 MAXIMUM AT 78F MEAN TEMPERATURE WITH FACTORY APPLIED LAMINATED ALUMINUM FOIL AND WHITE KRAFT PAPER VAPOR BARRIER JACKET. 9. DOMESTIC COLD WATER PIPING AND SUSPENDED HORIZONTAL STORM SEWERS AND ALL FITIINGS SHALL BE INSULATED WITH: (INSTALL AS RECOMMENDED BY MANUFACTURER). A. 1�2" THICK INSULAl10N W/ FRK WRAP FOR PIPING UP TO 1-1/4" DIAMETER. B. 1 THICK AT STORM C. SEAL BUTT & LONGITUDIAL JOINTS W/ WATERPROOF SEALANT. 10. PIPE INSULATION AT ALL PIPE HANGERS SHALL CONSIST OF INSUL-SHIELD FIBERGLASS PIPE SUPPORTS AS MANUFACTURED BY INSUL-COUSIIC OR ARCHITECT/ENGINEER APPROVED EQUAL. 11. HANGERS SHALL BE OF STANDARD WEIGHT STEEL OR IRON ROD AND RING OR CLEVIS TYPE. PROCEDURES: 1. ALL SUSPENDED HORIZONTAL PIPING SHALL BE SUPPORTED BY HANGERS SPACED NO FURTHER THAN 8' - 0" APART (4' -0" APART FOR PVC PIPING). NO PIPING SHALL BE SELF-SUPPORTING NOR BE SUPPORTED FROM EQUIPMENT CONNEC110NS. 2. ALL PARALLEL PIPES [TWO (2) OR MORE] SHALL BE SUPPORTED ON A CHANNEL TYPE TRAPEZE HANGER. 3. SUPPORTS AND HANGERS SHALL BE INSTALLED TO PERMIT FREE EXPANSION AND CONTRACTION IN PIPING SYSTEMS UNLESS PIPE REQUIRES FlRM ANCHOR CONTROL. 4. HORIZONTAL SOIL OR WASTE LINES SHALL BE AT A SLOPE OF NOT LESS THAN 1/S" PER FOOT AND SHALL BE HELD CLOSE TO THE CONSTRUC110N TO MAINTAIN A MAXIMUM OF HEAD ROOM. ALL CHANGES OF DIRECTION AND JUNC110NS SHALL BE MADE WITH "Y" FITTINGS AND 1/8" BENDS. NO UNES OF ANY KIND SHALL BE LOCATED BELOW FREEZERS. ALL DRAIN LINES SHALL BE PROTECTED FROM FREEZING. 5. HOT AND COLD WATER PIPING SHALL BE PROPERLY PITCHED TO LOW POINTS IN THE SYSTEM WHERE DRAINS SHALL BE INSTALLED. 6. CLEANOUTS SHALL BE PLACED AT ALL DEAD ENDS� AT CHANGES OF DIREC110N, AT 50'-0" INTERVALS ON HORIZONTAL RUNS� OUT OF HIGH TRAFFlC AREAS� (NOT UNDER CASES) ETC. WHERE CLEANOUTS OCCUR IN CONCEALED SPACES� THEY SHALL BE PROVIDED WITH EXTENSIONS TO FLOOR ABOVE OR TO WALLS. A HAND-HOLE TEST TEE SHALL BE PLACED AT THE BASE OF EACH STACK. 7. VENT STACKS EXTENDING UP THROUGH THE ROOF SHALL BE FLASHED WITH SIX POUND SHEET LEAD. FLASHING SHALL EXTEND 12" IN ALL DIREC110NS FROM THE VENT, CARRIED OVER AND TURNED DOWN THE INSIDE OF THE VENT. ALL SEAMS AND JOINTS OF FLASHING SHALL BE SOLDERED AND PROVEN WEATHERTiGHT. EXTEND VENTS A MIN. OF 12" ABOVE ROOF, AND 30" AWAY FROM PARAPET. 8. ALL SUPPLY PIPING TO BE RUN OVERHEAD, UNLESS NOTED OTHERNASE. 9. ALL SUPPLY PIPING TO BE A MINIMUM OF 3/4" DIA. 10. EACH FIXTURE WILL HAVE A 3/4" X 12" AIR CHAMBER. 11. PROVIDE SERVICE VALVE AT BRANCHES AND AT ALL APPLIANCES. 12. ALL FlXTURES WILL BE FURNISHED WITH INTEGRAL STOPS. 13. BURIED SANITARY AND WASTE LINES WILL BE A MINIMUM OF 4" DIA. 14. ALL FLOOR DRAINS AND FlXTURES TO BE VENTED IN ACCORDANCE IMTH LOCAL CODES. 15. ALL HORIZONTAL VENT PIPING SHALL BE RUN ABOVE FlNIS'FiED CEIUNGS AND SLOPED UP TOWARD MAIN STACK. 16. THE PLUMBING CONTRACTOR WILL NOT INSTALL COMBUSTIBLE PIPING MATERIAL IN OR THROUGH FlRE RATED ASSEMBLIES. 17. HORIZONTAL DRAINAGE PIPING SHALL BE PITCHED NOT LESS THAN 1/4" PER FOOT FOR PIPING 3" DIA. AND UNDER. 18. HORIZONTAL DRAINAGE PIPING SHALL BE PITCHED NOT LESS 1HEN 1/8` PER FOOT FOR PIPING 4" DIA. AND OVER. 19. ALL EQUIPMENT DEVICES SHALL BE INSTALLED WITH UNIONS IN SUCH A MANNER TO FACILITATE EASY REMOVAL AND MAINTENANCE OF EQUIPMENT WITHOUT DISRUPTING SERVICE AND CAUSING MAJOR PIPING REVISIONS. 20. ALL CONNECTIONS BETWEEN DISSIMILAR METALS SHALL BE MADE WITH DIELECTRIC UNI�IS OR COUPLINGS. � I13-892-491 � �S�MY 1°��'s Siwcc 19+J3 �O;LD'f OEER'!'£�T b °paR�er:aanwscgE � ,,:;R�; ,,1•`�� --��� r %�., ;; �`' <<. � � r'{� '%: �.�, �`��r.� �.µ:.����`����';_ _ ' y��r� ���;h.;�,� ', � l ;�` ; :.'.;;�� �" �". ':.%1M.'z�'�'��'�'��.,. .-,, .�;` .. � „" :�,.......... ��� �/, V �,1~��~a�4 '\ '� . '.r,;r,:;F::,�;�: � � � m ME N � N V � � �m N �� =T a�i a �•� J j( ' a a �N. o� d� .� a � N �� 'o 0 0� �. ��, o N N � .°' � w N �� � �� 0 � W P� h�l � � � � M"� � � �A OO^ a� � � � r ' � � �rT, � F+1 � F�I � � � � � V I DATE:B�?.3`13 DATE REVISED 1 SHEET TITLE MEP NOTES AND SCHEDULES 1 SHEET NUMBER A a � � z � � � � W a A � o � � i �m� �, d' �'z� ��� w a ��H � '�Uif1 z o x ti o �� E ;� � � � 0 � MEP 2 1 OF: 1 \