HomeMy WebLinkAbout15120002 Building Plans���Zi . , �
IN THE VENT OF IJESTIONS R ARDIN THE TH T A T R HA P I F i T R F R T PR T A A N APP I A F R
E Q EG G E CON R C 0 S �L BE RES ONS B�E OR REVIEWED SHOP DRAW NGS AND SIJBMIT A�S BY E E 0 OJEC M NU L(W EN L C BLE) 0
CONTRACT DOCUMENTS, SPECIFICATIONS, EXISTING FAMI�IARIZING HIMSELF WITH THE PROJECT SCOPE OF OTHERS SHAL� NOT BE CONSIDERED AS PART OF ADDITIONAL REQUIREMENTS AND DIRECTIONS.
CONDITIONS OR DESIGN INTENT, TNE CONTRACTOR WORK, BUILDING STANDARDS, SCHEDIJLE AND DEADLINES. TNE CONTRACT DOCUMENTS. THE ARCNITECT ALL INTERIOR FINISHES SHALL COMPLY WITH
SHAL� BE RESPONSIB�E FOR OBTAINING THE CONTRACTOR SHALL FIJRTHER BE RESPONSIBLE ASSIJMES NO RESPONSIBILITY FOR DRAWINGS, CHAPTER EIGHT (8) OF TNE 2012 INTERNATIONA�
C�ARIFICATION FROM THE ARCHITECT PRIOR TO BID FOR ADVISING THE OWNER OF ALL �ONG LEAD ITEMS SCHEDU�ES, AND/OR SPECIFICATIONS FOR WORK BIJILDING CODE WITH INDIANA AMENDMENTS.
SUBMITTAL AND PROCEEDING WITH ANY WORK AFFECTING THE PROJECT SCHEDULE AND SHALL, ON THE PROJECT PREPARED BY OTHERS. LIGHT GAGE METAL STUDS; STUDS, THEIR COMPONENTS
IN QIJESTiON. UPON REQUEST FROM THE OWNER, SUBMIT ORDER AND TNEIR CONNECTIONS SHA�L BE ENGINEERED BY A
CONFIRMATIONS AND DE�IVERY DATES FOR SUCH LONG THE ARCHITECT WILL REVIEW AL� SHOP DRAWINGS, PROFESSIONAL ENGINEER LICENSED IN THE STATE
THESE CONTRACT DOCUMENTS ARE INTENDED TO LEAD ITEMS TO THE OWNER. SUBMITTALS AND SAMPLES FOR CONFORMITY WITH
DESCRIBE ON�Y THE SCOPE AND APPEARANCE OF THE CONTRACT DOCUMENTS AND RETURN THEM TO WHERE THE PROJECT IS LOCATED. TNE ENGINEER SHALL
TNE REA� PROPERTY IMPROVEMENTS, INC�UDING THE ALL CONTRACTOR OR SIJPP�IER REQUESTS FOR THE CONTRACTOR WITHIN SEVEN (7) WORKING DAYS AFFIX THEIR SEAL AND SIGNATURE TO SHOP DRAWINGS
PERFORMANCE AND LEVEL OF Ql1ALITY EXPECTED OF Sl1BSTITUTIONS OF SPECIFIED ITEMS SHA�L BE EXCEPT AS MAY OTHERWISE BE PROVIDED FOR BY AND CALCU�ATIONS SIJBMITTED FOR REVIEW.
SIJBMITTED, IN WRITING, ACCOMPANIED BY THE
OF ITS COMPONENTS. IT IS THE CONTRACTOR'S THE OWNER.
T R IR T TRA IT RA ITY A R AT RA
RESPONSIBILITY TO INSIJRE THAT ALL WORK ALTERNATIVE PRODUCT INFORMATION, TO THE S EEL EQU ED 0 NSM G V ND/0 � E L
COMPLETED AND MATERIALS INSTA�LED BE IN FULL ARCNITECT, NO LATER THAT TEN (10) BUSINESS THE CONTRACTOR SHA�L NOT REPRODIJCE AND MARK LOADS TO THE STRUCTURE NOT DETAI�ED ON THE STRUCT.
COMPLIANCE AT A MINIMUM, WITN ALL APPLICABLE DAYS, PRIOR TO BID OPENING DATE. SUBSTITlJTIONS UP ANY PART OF THE CONTRACT DOCUMENTS FOR DRAWINGS IS THE RESPONSIBILITY OF THE METAL STUD
CODES, REGULATIONS, AND ORDINANCES HAVING SHA�� ONLY BE CONSIDERED IF THEY DO NOT SUBMITTAL AS A SHOP DRAWING. ANY SIJCH SUPPLIER TO DESIGN, DETAIL, PROVIDE AND INSTALL.
JURISDICTIONAL AUTNORITY OVER TNE PROJECT. SACRIFICE QIJALITY, FIJNCTIONALITY, APPEARANCE OR SIJBMITTAL WILL BE REJECTED. META� STUDS SHALL BE DESIGNED TO SUPPORT THE
WARRANTY. UNDER NO CIRCUMSTANCES WIL� THE ANY SUBMITTAL REQUIRED TO BE REVIEWED MORE LOADS SHOWN IN THE DESIGN DATA IN ADDITION TO
THESE CONTRACT DOCUMENTS DO NOT ATTEMPT TO OWNER BE REQl11RED TO PROVE THAT A PRODUCT THAN TNE INITIAL REVIEW AND ONE (1) ADDITIONAL TNE WEIGHT OF TNE MATERIALS ATTACHED TO THE
INSTRUCT THE CONTRACTOR IN THE DETAILS OF NIS PROPOSED FOR SUBSTITUTION IS OR IS NOT OF REVIEW, WI�L BE CONSIDERED TO BE IN EXCESS OF METAL STUDS. METAL STUDS SHALL BE DESIGNED IJSING
TRADE. THEY ARE PERFORMANCE SPECIFICATIONS EQUAL QUALITY TO THE PRODIJCT SPECIFIED. THE SCOPE OF THE PROJECT. THE TIME REQUIRED THE LOAD COMBINATIONS IN SECTION 1605.3.1 OF THE
IN THAT THEY DO REQUIRE THAT ALL MANUFACTURED UNDER NO CIRCl1MSTANCES SHA�L THE CONTRACTOR FOR THIRD AND SUBSEQIJENT REVIEWS OF A INTERNATIONAL BUI�DING CODE, 2012 EDITION. NO
ITEMS, MATERIALS AND EQUIPMENT BE INSTA�LED IN SCALE TNE DRAWINGS TO DETERMINE DIMENSIONS. SUBMITTAL WILL BE PAID FOR BY THE CONTRACTOR INCREASE IN ALLOWABLE STRESS IS A��OWED.
STRICT CONFORMANCE TO TNE MANUFACTURER'S REFER TO PLANS, SECTIONS AND DETAILS FOR ALL TO THE ARCHITECT AT THE ARCHITECT'S STANDARD DEFLECTION Dl1E TO LATERAL LOAD SNAL� BE LIMITED
RECOMMENDED SPECIFICATIONS, EXCEPT IN THE DIMENSIONAL INFORMATION. BI��ING RATES, PLUS REIMBURSABLE EXPENSES. TO 36o OF TNE STIJD SPAN. FOR CANTI�EVERS, THE
CASE WHERE THE CONTRACT DOCUMENTS ARE MORE THE CONTRACTOR SHA�� BE RESPONSIB�E FOR THE THE CONTRACTOR SHAL� BE RESPONSIBLE FOR DEFLECTION DIJE TO LATERAL LOAD AT TNE END OF THE
STRINGENT. ANY MISCE�LANEOUS ITEMS OR INSTALLATION OF ALL SELECTED MATERIA�S WHICH VERIFICATION OF ANY EXISTING CONDITIONS AND A�L CANTI�EVER SNAL� BE LIMITED TO � OF THE
MATERIALS NOT SPECIFICA�LY NOTED, BIJT REQUIRED SHAL� BE COMPLETE IN A�L RESPECTS PRIOR TO THE CRITICAL DIMENSIONS ASSOCIATED WITH THE CANTILEVER DIMENSION.
FOR PROPER INSTALLATION SHALL BE FURNISNED FINAL ACCEPTANCE, IJNLESS OTHERWISE NOTED. PROPOSED WORK. THE CONTRACTOR SNA�L CONFIRM
AND INSTALLED BY THE CONTRACTOR. TNAT ALL WORK OUTLINED WITHIN THE CONTRACT META� STUD MANUFACTURER SHALL DETERMINE FINA�
ALL WORK SHALL BE WARRANTED SATISFACTORY, IN TNE CONTRACTOR SNAL� PRESERVE ALL PRINTED DOCUMENTS CAN BE ACCOMP�ISHED AS SHOWN, PRIOR LAYOUT AND GAUGE OF STIJDS TO MEET THE
MATERIA�S AND WORKMANSHIP FOR A PERIOD OF �NSTRUCTIONS AND WARRANTY INFORMATION THAT IS TO BID OPENING. TNE CONTRACTOR SHALL NOTIFY ARCNITECTURAL AND STRUCTURAL REQUIREMENTS.
ONE (1) YEAR, OR FOR TNE PERIOD OF WARRANTY PROVIDED WITH EQIJIPMENT OR MATERIALS USED, AND THE ARCHITECT OF ANY CONDITIONS ENCOUNTERED WHERE ROl1GH CARPENTRY IS IN CONTACT WITH THE
CUSTOMARY, OR STIPULATED FOR THE TRADE, CRAFT, DELIVER SAID PRINTED MATTER TO THE OWNER AT THE WNICN MAY AFFECT BIJILDING CODE COMPLIANCE, GROUND, EXPOSED TO WEATHER OR IN AREAS OF HIGH
OR PRODIJCT, WHICHEVER IS LONGER. ONLY TIME OF SUBSTANTIAL COMP�ETION. THE CONTRACTOR �IFE SAFETY, ISSUANCE OF CERTIFICATE OF RELATIVE NUMIIDITY PROVIDE FASTENERS AND
COMPETENT MECNANICS CAPABLE OF PRODl1CING SHALL INSTRUCT THE OWNER IN THE PROPER USE OCCUPANCY, OR COMPLETION OF THE PROJECT AS ANCHORAGES WITH A HOT DIP ZINC COATING OF G90
GOOD WORKMANSHIP CUSTOMARY TO THE TRADE OF THE EQUIPMENT Fl1RNISHED BY THEIR TRADE. DIRECTED IN THE CONTRACT DOCUMENTS. COMPLYING WITH ASTM A153 OR PROVIDE FASTENERS
SHOULD BE USED. COMMENCING WORK BY A GENERAL CONTRACTOR SNALL PROVIDE A TNOROUGN NO ADDITIONAL FIJNDS WIL� BE APPROVED FOR WORK AND ANCHORAGES OF TYPE 304 STAINLESS STEEL.
CONTRACTOR OR SUBCONTRACTOR CONSTITUTES CONSTRUCTION CLEANING AT PROJECT C�OSE OUT, OMITTED FROM THE CONTRACTOR'S BID DUE TO LACK WHERE TREATED Ll1MBER (ROUGH CARPENTRY) IS IN
ACCEPTANCE OF THE CONDITIONS AND SURFACES PRIOR TO PIJNCN �IST WALK THROIJGH. OF VERIFICATION BY THE CONTRACTOR, EXCEPT AS CONTACT WITH OTHER MATERIALS IT MUST BE SEPERATED
CONCERNED. IF ANY SUCH CONDITIONS ARE THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF OTNERWISE APPROVED BY THE OWNER FOR WORK FROM THESE MATERIALS BY A PROD�CT THAT WI�L NOT
UNACCEPTABLE, THE GENERAL CONTRACTOR SHAL� BE ASSOCIATED WITH HIDDEN CONDITIONS WHICH ARE NOT A��OW ANY REACTION BETWEEN TNE PRESERVATIVE AND
AL� FABRICATED ITEMS, AND PHYSICAL SAMP�ES OF
NOTIFIED IMMEDIATE�Y, AND NO WORK SHALL BE ACCESSIBLE PRIOR TO CONSTRUCTION. ADJACENT MATERIAL. COORDINATE WITH LUMBER MANU.
PERFORMED IJNTIL THE CONDITIONS ARE CORRECTED. AL� FINISH MATERIA�S SPECIFIED TO THE ARCHITECT
FOR REVIEW. ALL WOOD SHEATHING TO BE FIRE TREATED UNLESS NOTED
OTHERWISE.
TYPE W5
TOP OF WALL
@ 8'-0" AFF
3�" MTL STUDS @ 16" O.C.
WITH ONE LAYER OF $"
STD BOARD ON EACH SIDE
AND TOP OF WAL�
6" MT� STIJDS @ 16" O.C.
WITN ONE LAYER OF 8"
GYPSUM BOARD @ EACH
SIDE. EXTEND STUDS AND
GYP BD. TO UNDERSIDE OF
ROOF DECK AND SEAL
BETWEEN GYP BD AND
DECK FOR FIRE RATED
ASSEMBLY.
PROVIDE SOUND BATTS
INSU�ATION TO MATCH WA�L
WIDTH AT WALL TYPE W4A
ONLY.
TYPE W4
TYPE W4A
(PROVIDE ONE HOUR RATED
UNDERWRITERS LABORATORY
WALL ASSEMBLY �465 OR
EQUA�)
TYPE W3
TYPE W3A
3$" MTL STUDS @ 16" O.C.
WITH ONE LAYER OF $"
GYPSUM BOARD @ EACH
SIDE. EXTEND TO
UNDERSIDE OF ROOF DECK
PROVIDE SOUND BATTS
INSU�ATION TO MATCH WA�L
WIDTH AT WALL TYPE W3A
ONLY.
.
. ,
6" MTL STUDS @ 16" O.C.
WITH ONE LAYER OF $"
GYPSUM BOARD @ EACH
SIDE. EXTEND GYP BD TO
MIN OF 4" ABOVE
ADJACENT CEILING �INE.
PROVIDE SOUND BATTS
INSIJLATION TO MATCH WAL�
WIDTN AT WA�L TYPE W2A
ON�Y.
WALL TYPE GENERA� NOTES
NOTE; WA�� HEIGHT AS MARKED ON PLANS IN USE MOLD AND MILDEW RESISTANT GYPSUM REFER TO ROOM FINISH SCHEDU�E FOR AL�
CONJUNCTION WITH WA�L TYPE SYMBOL WI�L WA�LBOARD ON ALL P�UMBING WALLS. USE $" FINISH SELECTIONS; CEILING TYPES AND HEIGHTS;
SUPERCEDE WA�L HEIGNTS AS SNOWN ABOVE. CEMENT BOARD INSTEAD OF GYP BOARD AND TYPES, SIZES AND LOCATIONS ETC.
SEE SYMBOLS LEGEND THIS SNEET. BEHIND AL� TILE FINISHES.
WALL TYPES I
NOT TO SCALE
.
. ,
! ' �
• ' • • �
CEILING LINE
SEE REF�ECTED CEILING
PLAN FOR HEIGHT.
38" MTL STUDS @ 16" O.C.
WITH ONE LAYER OF $"
GYPSUM BOARD @ EACH
SIDE. EXTEND GYP BD TO
MIN OF 4" ABOVE
ADJACENT CEILING �WE.
PROVIDE SOIJND BATTS
INSULATION TO MATCH WALL
WIDTN AT WA�L TYPE W1A
ON�Y.
FIN. F�OOR
� � � ' � ���
AFF ABOVE FINISHED F�OOR FD F�OOR DRAIN OD OUTSIDE DIAMETER
ACT ACOUSTICAL CEILING TILE FW FINISH OPNG OPENING
APP APPROXIMATE FLR F�OOR OPP OPPOSITE
ARCH ARCHITECT FT FEET OH OPPOSITE HAND
AWT ACOUSTICAL WALL TREATMENT FD F�OOR DRAIN OTO OUT TO OUT
BLKG BLOCKING FE FIRE EXTINGl11SHER PLAS LAM PLASTIC LAMINATE
B.O. BOTTOM OF FEC FIRE EXTINGl11SNER CABINET PLWD PLYWOOD
BOT BOTTOM GA GAIJGE PS PROJECTION SCREEN
CAB CABINET GB GRAB BAR QT QUARRY TILE
CAR CARPET GWB GYPSIJM WA�LBOARD R RISER
CJ CONTROL JOINT RA RETURN AIR
CL CENTER LINE HDWR HARDWARE RB RESILIENT BASE
CMU CONCRETE MASONRY UNIT HM HOLLOW METAL
CO� CO�UMN HORIZ HORIZONTA� REF REFERENCE
CONC CONCRETE HVAC HEATING, VENTILATING, A�R COND. REFR REFRIGERATOR
CONST CONSTRUCTION HW HOT WATER REQD REQUIRED
CONT CONTINUOUS RO ROUGH OPENING
CT CERAMIC TILE �ST JOIST SA SUPP�Y AIR
CW CO�D WATER JT JOINT SCNED SCHEDULE
DET DETAIL KIT KITCHEN SEC SECTION
DF DRINKING FOl1NTAIN �AM �AMINATE SIM SIMILAR
DIM DIMENSION LAV �AVATORY SPECS SPECIFICATIONS
DRWGS DRAWINGS ��H LONG LEG HORIZONTAL SF SQUARE FOOT
EA EACH L�V LONG LEG VERTICA� SA SUPPLY AIR
EC EXPOSED CEILING MAS MASONRY SS STAINLESS STEEL
EJ EXPANSION JOINT MAX MAXIMUM STD STANDARD
EIFS EXTERIOR INSU. FINISH SYSTEM MB MARKER BOARD STL STEEL
EL E�EVATION MECH MECHANICAL SUSP SUSPENDED
EL E�EVATION MEZZ MEZZANINE TB TACK BOARD
ENG ENGINEER MFR MANUFACTURER TEL TELEPHONE
EXIST EXISTING MIN MINIMl1M T.O. TOP OF
EXP EXPANSION M.O. MASONRY OPENING TV TELEVISION
EXT EXTERIOR TYP TYPICA�
��� � ' ' �►�
APPLICABLE CODES
INDIANA BUI�DING CODE
2014 INDIANA BIJILDING CODE
INDIANA P�UMBING CODE
2012 INDIANA P�UMBING CODE
INDIANA ELECTRICA� CODE
2009 INDIANA ELECTRICAL CODE
INDIANA FIRE CODE
2014 INDIANA FIRE CODE
INDIANA MECHANICA� CODE
2014 INDIANA MECHANICA� CODE
INDIANA ENERGY CONSERVATION CODE
2010 INDIANA ENERGY CONSERVATION CODE
INDIANA NANDICAPPED ACCESSIBILITY CODE
2009 ANSI A117.1
ADA ACCESSIBILITY GUIDELINES
OCCUPANCY (OVERALL BUILDING)
C�ASSIFICATION (302.1):
OCCUPANCY (TENANT SPACE)
C�ASSIFICATION (302.1):
ACCESSORY USES (508.3.1):
NON—SEPARATED IJSES (508.3.2):
SEPARATED USES (508.3.3):
CONSTRUCTION
C�ASSIFICATION (602):
AUTOMATIC SPRINKLER SYSTEM
SPRINKLER SYSTEM REQUIRED (903):
SPRINKLER SYSTEM PROVIDED:
ALLOWABLE BUILDING HEIGHT
TABU�AR NEIGHT (503):
ALLOWABLE BUILDING AREA
TABU�AR AREA (503):
BUILDING AREA INCREASE
INCREASE FOR SPRINKLERED Bl1ILDING (506.3)
UN�IMITED AREA (507):
FRONTAGE INCREASE (506.2):
If = (F/P—.25)xW/30
TOTAL A�LOWABLE AREA WITN INCREASES:
ao=at+�atXif)+(atXis)
Aa = FILL IN
:
B
N/A
N/A
N/A
:
YES
YES
55'/4 FLR
�►��iiZ1��
300%
N/A
N/A
50,000 SF
ACTUAL BUILDING HEIGHT AND AREA
BUI�DING AREA: 18,284 SF
BUI�DING HEIGHT (FEET/� FLOORS): 31'-8"/1 FLR
TENANT AREA: 1,352 SF
UON
UR
VCT
VERT
VT
W/
W/0
WB
WC
WD
WH
WP
UNLESS OTHERWISE NOTED
IJRINAL
VINYL COMPOSITION TI�E
VERTICAL
VINYL TI�E
WITN
wiTHouT
WOOD BASE
WATER C�OSET
WOOD
WATER HEATER
WORKING POINT
TABULAR OCCUPANT LOAD ( I 004. I.2)
OCCIJPANT �OAD FACTOR:
BUSINESS: 1/100 SF
KITCHEN: 1 /200 SF
ACTUAL OCCUPANT LOAD (1004.1.2)
SQUARE FOOTAGE/OCCUPANT LOAD FACTOR:
BUSINESS: 673/100 SF
KITCHEN: 679/200 SF
TOTAL OCCUPANTS: 11
FIRE RESISTIVE REQUIREMENTS (601 AND 602)
CONSTRIJCTION TYPE: 1 1-B
STRIJCTURAL FRAME: NON-RATED
EXTERIOR BEARING WALLS: N/A
INTERIOR BEARING WA�LS: N/A
EXTERIOR NON—BEARING WALLS: NON—RATED
INTERIOR NON—BEARING WAL�S: 1 HR. DEMISING
F�OOR CONSTRUCTION: NON—RATED
ROOF CONSTRUCTION: NON—RATED
SHAFTS: NON—RATED
FIRE RESISTANCE RATED CONSTRUCTION (704, 601, 602}
RATED EXTERIOR WALLS: N/A
FIRE SEPARATION DISTANCE: >30'
11NPROTECTED OPENING AREA: N/A
INTERIOR WALL AND CEILING FINISH REQUIREMENTS (803)
SEE FINISH SCHEDULE FOR MATERIALS
ALL MATERIALS ARE C�ASS A RATED
FIRE PROTECTION SYSTEMS
STANDPIPE SYSTEM (905): DESIGN BUI�D
PORTAB�E FIRE EXTINGIJISHERS (906.1): BY TENANT
FIRE A�ARM AND DETECTION SYSTEMS (907): REQIJIRED
SMOKE CONTRO� SYSTEMS (909): N/A
SMOKE AND HEAT VENTS (910): N/A
EGRESS
MINIMUM WIDTH FACTOR (1005.1): .15"
REQUIRED MINIMUM WIDTH FROM SPACE (10Q5.1): 2,2"
MINIMUM NUMBER OF EXITS (1015): 1
ACT�A� NUMBER OF EXITS: 3
ACTl1A� WIDTH OF EXITS: 108'
ALLOWABLE TRAVEL DISTANCE (1016.2}: 300'
CORRIDOR CONSTRIJCTiON (1018.1): NOT RATED
MINIMUM CORRIDOR WIDTH {1018.2): 44`
MAXIMIJM DEAD END CORRIDOR (1018.4): 50'
.�
!
(NOT ALL MAY APPLY)
OKEYED NOTE
REFER TO SHEET WHERE SHOWN.
OWINDOW OR G�AZED OPENING TAG. SEE SCHED.
IF WINDOW — W?_ IF STOREFRONT — SF?,
IF CIJRTAINWA�L CW?
ID ACCESSORY TAG. SEE ENLARGED TOI�ET PLANS.
- � BUILDING SECTION CUT.
XXXX
ELEVATION TAG — INTERIOR OR EXTERIOR.
XXXX
x/xxx
- SECTION CUT AT AREAS SHOWN SMALL SCALE
� �
' �X/XXX
EN� LARGED PLAN.
� �
X-�XXXX E�EVATION TARGET.
XXXXX FINISH FLOOR = ASSUMED 0'-0" U.O.N.
xxx FINISH TAG. REFER TO LEGEND
L/��' V REVISION
N
PLAN OR TRUE NORTH
� BATT INSULATION; WIDTH OF FRAMING U.O.N.
G
� ROOM TAG. REFER TO ROOM FINISH SCHEDULE
ROOM
NAME
F.E. FIRE EXTINGUISHER IN SEMI—RECESSED
0 CABINET PROVIDED/INSTALLED BY GC.
SURFACE MOUNTED FIRE EXTINGUISHER
O PROVIDED/INSTA�LED BY G.C.
F.E.
100 DOOR WITH DOOR Nl1MBER.
� WINDOW OR GLAZED OPENING
a� LADDER. REFER TO SECTIONS AND NOTES
WH WA�L HYDRANT IF EXTERIOR
HB � HOSE BIB IF INTERIOR
� METAL STUD FRAMED WAL�. REFER TO
INDEX SHEET FOR INFO.
;� ;� CMl1 WALL. REFER TO SECTIdNS AND DETAILS
����y� BRICK WALL. REFER TO SECTIONS AND DETAILS
EIFS OVER SUBSTRATE. REFER TO
SECTIONS FOR WIDTH AND PROFILE.
� EXISTING DOOR. REFER TO DOOR SCHEDULE
�
EXISTING WINDOW WITH SILL AND/OR STOOL.
� � DEMO'D DOOR.
/
DEMO'D WALL.
W1 WALL TYPE
�
12' WALL HEIGHT IF DESIGNATED ON PLANS.
IF NOT, SEE WALL TYPES THIS SHEET.
� ' • L'
INDEX SHEET
ARCHITECTURAL
A1.1 FLOOR P�AN/ CEILING PLAN/
ELECTRICAL PLAN/LIFE SAFETY P�AN
A1.2 ROOM FINISN SCHED�LE/
DOOR SCHEDIJLE
EAST 146TH STREET
0
a
0
�
�
�,
>
PROJECT LOCATION �
Q ' �
�
,
�� ��'� ` �� � �t'; � � � ,��
� � j i r SY, 2# F.�
� y � �i ¢ {„y } �% ii
.0 �3. �� tr �� i��„' } ,z�,;
r� ��_ �t t r� �< ti�� � t�
_ aEs ,{S' ti j��� ht j`�v� a% �,n{
A HITE T E
6925 EAST 96TH ST., SUITE 105
INDIANAPO�IS, IN 46250
O:: 3 I 7. 288 . 068 I
F :: 317.288.0753
\\��,���u���i�ii,�
`\\\�\�P,�\NG\M.ERF v�� ��i.
V�
; ��. �� `�� ° � �� 9 %
� ��. � ;
= • : AR19600043 : • _
% STATE OF �
i �
��� N D I P N P ����
.
,9 ��,
,, ( ��
�i
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAWED HEREIN ARE
THE EXC�USIVE WTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
�O COPYRIGHT 2014, CURRAN ARCHITECTURE
PIZZA3I7
14580 RIVER ROAD
CARMEL, INDIANA 4b032
�•
//.
��
, . �
� �IP���T S��EDUL�
DESCRIPTION SIZE ELECTRICITY
1 OVEN DOUB�E, ROTARY BAND, GAS 61, 3/4" X 47, 1/2" X 63, 3/8" 208V
2 MIXER FLOOR PLANETARY SP30-30QT 22, 4"-W X 26, 2"-I X 48, 5"-H 1 HP
3 STOVE GAS, HOT PLATE, 4 BURNER 24" X 33, 1/8" X HEIGHT 13/16" --
4 PREPARATION TABLE PIZZA, 2 DOORS 67, 1/4" X 32, 1/4" X 35, 3/4" HP 1/3
5 UTI�ITY SINKS WITH 3 COMPARTMENT, STAINLESS STEEL 22" X 55, 3/8" X 16/304 --
6 WORK TABLES 4, 1/2 BACK SPLASH 24" X 36" --
7 WORK TABLES 4, 1/2 BACK SPLASH 24" X 60" --
8 WORK TABLES 4, 1/2 BACK SPLASH 24" X 48" --
9 WORK TABLES 4, 1/2 BACK SPLASH 24" X 36" --
10 REFRIGERATOR TRUE, FULL GLASS 3 DOOR 78, 1/8" X 29, 3/4" X 78, 3/8" HP 1/2
11 REFRIGERATOR TRUE, FUL� GLASS 1 DOOR 27" X 24, 3/4" X 75, 1/4" HP 1/3
12 FREEZERS TRUE, 2 SO�ID DOOR 54, 1/8" X 29, 1/2" X 78, 3/8" HP 3/4
13 REFRIGERATOR TRUE, FUL� GLASS 1 DOOR (REFRESCOS) 30" X 29, 7/8" X 78, 5/8" HP 3/4
14 HAND SINKS, BASIC SINK/ OVERFLOW 12", 9" X 9" X 5" BOWL --
15 HAND SINKS, BASIC SINK/ OVERFLOW 12", 9" X 9" X 5" BOW� --
16 MOP SINK STONE 20" X 18" X 6" HIGH LEVE� --
17 ADJUSTABLE SHE�VING WIRE GREEN EXPOSI 21" X 42" --
18 ADJl1STABLE SHELVING WIRE GREEN EXPOSI 21" X 42" --
19 ADJUSTABLE SHE�VING WIRE GREEN EXPOSI 21" X 42" --
EQUIPMENT SCHEDULE S
NOT TO SCALE
12 �
; g---
� �
9 FE
- 1 0.
�'
�
�' S i'�� � '��
,� 0 ,,-__
� � ``' 1 ; _�� ��
, �
�
, , �
� � 16 ' '
I - ._._�-�
I�I - � - - �
�,1 �
6 �1 0,,-_ _ __
1 ;
� �,
U � � ( � ' —
�-,,_____,_ ;' - �.
QI �
o� , , �
�1❑� 1
�, � � �
�-�15 Q � � �
� � � X
� � �o
4 � ��
1 1 �;'
1 �0 1 �
1 1 ,�,
� 1 Iz
1 -- 1 ¢
� 13 � o
� -- � w
8 ' ' �
' ' ~
19 � 14�0 � o ❑
----� 1
1
----------�
.`
♦
♦
♦
♦
1
Iw
v�
z
a W
'c��no
'o�-
J =
' j I.C)
O ' ~ � ❑
FE '��
LIFE SAFETY PLAN 4 ELECTRICAL PLAN
114" = I'-0"
3
114" = I'-0"
�v �;.
PARTIAL REFLECTED CEILING PLAN
REFLECTED CEILING PLAN
2
I/8" = I'-0"
� � �
1. 12" WIDE PLASTIC LAMINATE COUNTER ON PARTIAL
HEIGHT WALL. TOP OF COUNTER @ 34" AFF.
2. TOP OF WALLS @ RESTROOMS CAPPED W/ 6"
HEAVY GAUGE STUDS AND 4" F.R. PLYWOOD, TOP
OF P�YWOOD @ 8'-0" AFF. WAL�S SUPPORTING
THIS AREA TO BE SIZED BY STUD SUPPLIER TO
ACCOUNT FOR STORAGE ABOVE.
3. EXTEND CEILING OVER RESTROOM AREAS.
4. REPLACE GLAZING W/ SPANDREL G�ASS TO MATCH
BLDG STD.
5. WALL TO FRAME INTO MUL�ION. PROVIDE BRAKE
METAL CLOSURE TRIM W/HEMMED EDGE. MATCH
STOREFRONT.
6. EXPOSED STRUCTURE W/ DRYFALL FINISH.
7. EXISTING EXTERIOR EMERGENCY EXIT LIGHTS.
E�
BULKHEAD @ 8'-0" AFF.
VERIFY ALL POWER REQUIREMENTS Wf TENANT AND
EQUIPMENT Sl1PPL1ER.
10. HOOD LOCATION COORDINATE W/ SUPPLIER.
PROVIDE POWER AS REQUIRED.
11. GYP. BD RETURNS AT WINDOW HEADS, TYP.
12. FINISH EXTERIOR WALLS W/ R-19 BATT INSULATION,
VAPOR BARRIER, AND �" GYP. BD FULL HEIGHT.
TYPICAL.
13. FINISH EXISTING DEMISING WALLS AS REQUIRED TO
COMPLY W/WAL� TYPE W4A ON INDEX SHEET.
14. OUTLETS TO BE INSTAL�ED IN WALL BE�OW
STOREFRONT.
15. ALL OUTLETS IN KITCHEN TO BE AT 48" AFF U.O.N.
AND SHALL BE GFI PROTECTED.
16. GAS FIRED TANK-�ESS WATER HEATER MOIJNT ON
WA�L ABOVE MOP SINK.
• • � � �
I
I!8" = 1'-0"
GENERAL NOTES
1. CONTRACTOR SHA�L BE RESPONSIBLE FOR
VERIFICATION OF ALL DIMENSIONS AND JOB
CONDITIONS. ANY DEVIATION FROM WHAT IS NOTED
IN DRAWINGS SHALL BE BROUGHT TO THE ATTENTION
OF THE ARCHITECT IMMEDIATELY.
2. ALL DIMENSIONS SHOWN ARE FACE OF BRICK,
MASONRY OR GYP BOARD-l1NLESS NOTED
OTHERWISE.
3. BOTTOM PLATE OF ALL NEW WALLS SHALL BE
PRESSURE TREATED �UMBER.
4. PROVIDE FIRE RATED WOOD BLOCKING IN METAL
STUD WALLS FOR ANY WALL Sl1PPORTED ITEMS.
5. PROVIDE APPROVED FIRE RATED STOPPING MATERIALS
IN ANY OPENINGS IN FIRE RATED ASSEMBLIES.
6. REFER TO DOOR AND WINDOW SCHEDULES FOR A��
MATERIALS, FINISHES AND HARDWARE INFORMATION.
7. REFER TO EXTERIOR E�EVATIONS FOR A�L BRICK
MASONRY AND OTHER EXPANSION JOINT LOCATIONS.
8. ALL MATERIALS LOCATED IN CEILWG PLENl1M SHALL
BE RATED FOR SUCH INSTA�LATION OR PROTECTED
TO PROVIDE COMPLIANCE. THIS INC�UDES BUT IS
NOT LIMITED TO POWER AND LOW VOLTAGE WIRING,
TELECOMMUNICATIONS CABLING, P�UMBING SIJPP�Y
AND DRAIN LINES AND SUPPORTING BRACKETS
AND/OR BLOCKING FOR CEILING HUNG ITEMS.
9. PRIOR TO ORDERING ANY PRODUCTS-CONTRACTOR
SHALL SUBMIT SAMPLES TO THE ARCHITECT OF ALL
FINISH MATERIALS TO BE USED ON THE PROJECT.
THE CONTRACTOR SHAL� BEAR SO�E RESPONSIBI�ITY
FOR ANY MATERIALS ORDERED INCORRECT�Y WHEN
THAT MATERIAL WAS NOT REVIEWED BY THE
ARCNITECT.
ELECT/CEILING
�
NOT A�L MAY APP�Y
� WALL MOIJNTED DUPLEX OUTLET
a DUPLEX BOX IN WA�� WITH CONDUIT
AND PULL STRING ABOVE CEILING.
VOICE/DATA WIRING AND TERMINATION
BY TENANT'S VENDOR
+42" DENOTES MOUNTING HEIGHT OF ITEM
DIMENSION TO BOTTOM OF COVER
PLATE U.O.N.
GFI DEVICE ON GROUND FAULT
INTERRUPT CIRCUIT
2X4 FLl10RESCENT �IGHT FIXTURE
�p WITH ACRYLIC LENS. (2) 32WT8
LAMPS, 85 WATTS MAXIMIJM
,�, LED PENDANT LIGNT. �OCATION AND
FIXTURE TYPE TO BE SELECTED BY
TENANT. MAX WATTAGE 40 WATTS
� WA�L MOUNTED COMBO EMERGENCY
LIGHT AND EXIT LIGHT W/ 90 MIN.
BACKUP. EQUAL TO NAVILITE NXPC3GWH.
4.2 WATTS TOTAL STANDBY.
� EMERGENCY LIGHT - LITNONIA ELM2 LED
QUANTUM WITH BATTERY BACK-UP,
NEW CEILING GRID/TILE TO BE
INSTALLED
DIFFUSER - SUPPLY
DIFFUSER - RETURN
� COMBINATION FLUORESCENT LIGHT/FAN
Dl1CTED TO EXTERIOR. EQUAL TO BROAN
QTXE-150F�T WITH (2) 18 WATT LAMPS,
36 WATTS TOTAL.
$ WALL MOl1NTED LIGHT SWITCH.
3 = 3 WAY SWITCH
4 = 4 WAY SWITCH
D = E�ECTRONIC DIMMER
0 = OCCIJPANCY SENSOR
NOTE: HVAC SYSTEM AND HOODS ARE TO BE
ENGINEERED AND PERMITTED (INCLIJDING STATE
DESIGN RE�EASE) BY DESIGN-BUILD HVAC
CONTRACTOR.
EAST 146TH STREET
PROJECT LOCATION
� ` � � ; ��` �`
� � 4 x .� i� . � �
,� i rY"� ;i� � t �: ,}2 j� 1 ; t
�i �' pi t Y Z� t� + f
�
„3 �'s�'E ,� . � i' {��7 S tt .
hj� t$i � t t« '�t �' 1�;
r � ��� �� �
: � ,�� ,`. ,, {S rtt��
1 '� �
6925 EAST 96TH ST., SUITE 105
INDIANAPOLIS, IN 46250
O:: 3 I 7. 288 . Q68 I
F :: 3I7.288.0753
\``�ti��iiiiii�iri,�
: \\`\\PV�\E�-��M� E R���� /,�:
\ �,�. �� No.� 9�;
- • � AR19600043 � • _
% STATE OF �
i �
�� NDIANP ��
�
9 `\�
,� � �.
u
EXPIRES 12/31/15
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAWED HEREIN ARE
THE EXCLUSIVE INTEL�ECTUA� PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHO�E OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
OO COPYRIGH7 2014, CURRAN ARCHI7ECTURE
� ' ��
14580 RIVER ROAD
CARMEL, INDIANA 46032
il�:��i'��
150063
09.11.15
..��� ��
. , . ,
. '
MARK
102
103
104
105
106
MAKE
SC-1
QT-1
CL-1
STAIN
BASE
P-1
PL-1
FRP-1
CT-1
TYPE
F
F
F
F
SIZE
3'-0"x7'-0"
3'-0"x7'-0"
3'-0"x7'-0"
1'-6"x7'-0"
3'-0"x7'-0"
MATERIAL FINISH RATING FRAME MATERIAL FINISH
-- -- -- F1 KD P-1
SCWD PREFINISHED -- F1 KD P-1
SCWD PREFINISHED -- F1 KD P-1
SCWD PREFINISHED -- F1 KD P-1
SCWD PREFINISHED -- F1 KD P-1
MATERIAL MANUFACTURER
SEALED CONCRETE ASHFORD
QUARRY TI�E TBD
CEILING TILE TBD
CONCRETE STAIN TBD
GALV. STEEL --
PAINT TBD
PLASTIC LAMINATE TBD
FIBERG�ASS REINF. PLASTIC TBD
CERAMIC TILE TBD
�
�
O
�
�
O
m
O
�
M
I
M
a
O
�
O
�
O
M
CLEAR
TBD
TBD
TBD
TBD
TBD
TBD
TBD
RATING HARDWARE ROOM #
-- -- 100
-- 2 101
-- 2 102
-- 3 103
-- 1 104
-- -- 105
-- -- 106
COLOR PATTERN / TEXTURE
CURE-N-SEAL
TBD
WAASHABLE
TBD
4" TALL
TBD
TBD
TBD
TBD
TYPICA� ADA MOUNTING HEIGHTS I
NOT TO SCALE
TIE INTO EXISTING
SANITARY SEWER. 3 COMP �
/�� " SINK %�`'
. .
/- �..'��-;�,,� �'���iHW
.' ,� \`�'. I ' ' i��`�i.
/' �/� 7�\� .�/� � � J \`�
� i V
/'i� \ �����,�� ' \`. � �CW iCW �HW �
.�� ,�, �. i
i��' '�:� ..�-� � �cw ( ,r�Hw �W J � �
�. - � ' I cw , '
�/ i I �� . CW' iHW WC . J J WC H� � J CW
�' � ��W \ \�\' � �AV HEATER SI�NK LAV
�
HW � HAND / :'
SINK /��
i�
��.
.
.
�
i
HAND' ;
SINK J, J HW
cw
P�UMBING SUPP�Y ISO 3
NOT TO SCALE
NUMBER
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
ROOM NAME
ORDER/DINING
HA�L
KITCHEN
TOILET
TOILET
UTILITY ROOM
OFFICE
FLOORING
SC-1/
STAIN
sc-�/
STAIN
QT_1
SC-1/
STAIN
SC-1/
STAIN
SC-1/
STAIN
QT_1
COORDINATE WITH TENANT ON FINISHES
REMARKS
PROVIDE EPDXY GROUT
�
J
U
NORTH WALL EAST WAL� SOUTH WALL WEST WA�� CABINETSf CEILWG MAT.f REMARKS
COUNTERTOPS HEIGHT
P-1 P-1 P-1 P-1 PL-1 EXPOSED --
-- -- -- -- -- PAINT --
P-1 P-1 P-1 P-1 -- EXPOSED --
-- -- -- -- -- PAINT --
FRP-1 FRP-1 FRP-1 FRP-1 -- CL-1/ --
-- -- -- -- -- 14'-0" --
CT-1/ CT-1/ CT-1/ CT-1/ -- GYP BD/ CT-1 FROM FLOOR TO 48" AFF
PAINT PAINT PAINT PAINT -- 7'-6" --
CT-1/ CT-1/ CT-1/ CT-1/ -- GYP BD/ CT-1 FROM FLOOR TO 48" AFF
PAINT PAINT PAINT PAINT -- 7'-6" --
P-1 P-1 P-1 P-1 -- GYP BD/ --
-- -- -- �> 6„
FRP-1 FRP-1 FRP-1 FRP-1 -- CL-1/ --
-- -- -- -- -- 12'-0" --
ENLARGED RESTROOM PLAN Z
i iz° _ � �-o,.
NOTE: ACCESSORIES TYPICAL FOR BOTN RESTROOMS
MARK
TT i
GB1
Cel:Ya
T�
TD1
�'
TOILET ACCESSORY LEGEND
SYMBOL BOBRICK # DESCRIPTION REMARKS
B_288$ MU�TI-ROL� TOILET MOUNT 36" FROM BACK YdALL TO
TISSUE DISPENSER. OUTSIDE EDGE OF DISPENSER.
B-6806.99 X 36 36" GRAB BAR FOR BACK WAII AND 42" PROVIDE PEENED GRIP AND CONCEALED
B-6806.99 X 42 GRAB BAR FOR SIDE WA�L. INSTALL 6" MOUNTING WITH SNAP FLANGE.
FROM WALL TO START OF GRAB BAR
1" RA AR T RT A
MOUNTING
HEIGHT
20" A.F.F. TO CL OF
LOWEST ROLL
34" AFF TO
CENTERUNE
8 G B B MOUN ED VE IC LLY PROVIDE PEENED GRIP AND CONCEAIED 40" AFF TO BOTTOM OF
B-6806.99 X 18 A80VE SIDE GRAB BAR. INSTALL 40" MOUNTING WITH SNAP FLANGE. BAR
FROM BACK WALL TO CENTERLINE
DECORATIVE MIRROR PROVIDED BY OWNER, 40" AFF TO BOTTOM
BY OWNER MIRROR INSTALLED BY GC. COMPLY WITH ADA
REQUIREMENTS
TOWEL DISPENSER 600 C-FOLD OUNT 3'-6" TO ACTUAt
0 8-4262 TOWE� DISPENSING
OPENING.
� 8-4112 SOAP DISPENSER 40 OZ 40" AFF TO
CENTERLINE
HARDVVARE SC H E D� LE
HARDWARE SET �1
3 HINGES
1 OFFICE LOCKSET
3 MUTES
1 WALL STOP
f '���� �_ � � �
J
3" VENT THRl1
ROOF
� �" � �� �� I �� �
� � I
�
I �'� � ��� ����� �
I � � � � � I
I
I � ��,� '�� I 3 COMP. �
� � � SINK �
I
I �� � � ' 1 1�2" �
� I �
� � � GREASE I
� � I ��INTERCEPTOR
� HAND / i MOP� <�K� LAV
� SINK � LAV SINK�� /�, �
> >/2" �� -��/ > >/2"---��`� -��'�'``, ,'�i �/2i' w.c. �.� �� �/2„
—I ,,� I / �� \G / � �J
� ��. y� w.c. ���
�-,
�� �
� HAND ��
TIE INTO EXISTING �/ SINK i �.�
SANITARY SEWER. � �
� � ��2/ �,
I /,
V�
P�UMBING WASTE ISO 4
NOT TO SCALE
SEE SCHEDtJLE
�
�
�
0
w
_
v
cn
w
w
c/�
TYFE F
� 1 �•
��1 1��'
HARDWARE SET �2
3 HINGES
1 PRIVACY SET
3 MUTES
1 WALL STOP
1 C�OSER
HARDWARE SET �3
3 HINGES
1 STOREROOM LOCK
3 MUTES
TYPE F 1
KEYED NOTES
1. ADA COMPLIANT TANK-TYPE TOILET. SEE TYPICAL
INSTALLATION DETAILS THIS SHEET.
2. ADA COMPLIANT LAV. TOP AT 34" AFF. PROVIDE
PROTECTIVE COVERS ON SUPPLY/WASTE LINES.
�' �;�` t� 4� , � ;�`� �
�� '� �i if 17, i� l�'., if t �)�r} �
�� � ,� ,t r
�� �� � r� �, j�� � � �, � �
�� .�,� tYi pi � � � ��. 4� i
�{ i$� tj �ti, {. 4 f�,
Yr { t .
A HITE T E
6925 EAST 96TH ST., SUITE 105
INDIANAPOLIS, IN 46250
O:: 3 I 7. 288 . Q68 I
F :: 3I7.288.0753
\``�ti��iiiiii�iri,�
���\`\\P�• �' �\S T� E R f v"� /�ii
� ��.. � ��' ° ��� . 9 �
� No. ���
- • � AR19600043 � • _
% STATE OF �
�� NDIAN? \\�
�
9 `\�
,, � �.
u
EXPIRES 12/31/15
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAWED HEREIN ARE
THE EXCLUSIVE INTEL�ECTUA� PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHO�E OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
OO COPYRIGH7 2014, CURRAN ARCHI7ECTURE
PIZZA 3 I 7
14580 RIVER ROAD
CARMEL, INDIANA 46032
;��remr���
09.11.15
1500b3
ROOM FINISH SCHEDULE/
DOOR SCHEDU�E
�