HomeMy WebLinkAbout15120002 MiscellaneousInterior Lighting Compliance Certificate Project Title: 90.1 (2007) Standard Project Type:Alteration Construction Site:Owner/Agent:Designer/Contractor: Project Information Energy Code: Pizza 317 Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Common Space Types:Dining Area - Family Restaurant 1352 2 2839.10 2839Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Common Space Types:Dining Area - Family Restaurant (1352 sq.ft.) Linear Fluorescent 1: 48" T8 32W (Super T8): Electronic: 3 16 107 1712 Compact Fluorescent 1: Twin Tube 18W: Electronic: 2 2 36 72 LED 1: Other:1 8 40 320 2104Total Proposed Watts = Interior Lighting Compliance Statement Interior Lighting PASSES 10/3/15 Mechanical Compliance Certificate Project Title: 90.1 (2007) Standard Project Type:Alteration Location:Carmel, Indiana Climate Zone:5a Construction Site:Owner/Agent:Designer/Contractor: Project Information Energy Code: Pizza 317 Mechanical Systems List Quantity System Type & Description Gas Instantaneous Water Heater, Capacity: 0 gallons, Input Rating: 75 Btu/h Proposed Efficiency: 85.00 EF, Required Efficiency: 0.62 EF SWH COMPLIANCE REQUIRED. 1 Water Heater 2 Mechanical Compliance Statement 10/3/15