Loading...
HomeMy WebLinkAbout_Construction Plans.pdf* N.P.= 10 YEAR ELEV.= 2 YEAR ELEV.= 100 YEAR ELEV.= DETENTION BASIN DRY 853.81 854.66 855.19 * * * CLARIAN HEALTH PARTNERS, INC. INSTRUMENT #200300092214 PLANS CERTIFIED BY: Owner/ Developed by: SOHUM DEVELOPMENT, LLC 7050 East 21st Street Indianapolis, IN 46219 Phone: 317-357-8236 Contact Person: RAVI PATEL email: ravi@sohumhospitalty.com LOCATION MAP SCALE: 1" =800' SOILS MAP SCALE: 1" =400' REVISIONS DESCRIPTION SHT.DESCRIPTION COVER SHEET TOPOGRAPHICAL SURVEY/DEMO PLAN SITE PLAN, GRADING PLAN INDEX DESIGN DATA 2.29 AC. FLOOD MAP SCALE: NTS CONSTRUCTION DETAILS STORM PLAN & PROFILES & SUB SURFACE DRAIN PLAN C001 C100-C102 C200-C201 C600 C800-C803 SHT. 11/20/15 EROSION CONTROL PLAN & SPECIFICATIONSC300-C304 # OF PARKING SPACES 87 UTILITY PLAN, SIGNAGE PLANC400-C401 SITE HYATT PLACE PLANS PREPARED BY: STOEPPELWERTH & ASSOCIATES, INC. CONSULTING ENGINEERS & LAND SURVEYORS 7965 EAST 106TH STREET FISHERS, INDIANA 46038 PHONE: (317)-849-5935 FAX: (317)-849-5942 CONTACT PERSON: BRETT A. HUFF EMAIL: bhuff@stoeppelwerth.com NOTES: 1.THIS SITE DOES NOT LIE WITHIN A FLOODPLAIN PER FIRM MAP NO. 18057C0209G DATED NOV. 19TH, 2014. 2.UTILITY CONFLICTS (INCLUDING UTILITY POLES) MUST BE COMPLETELY RESOLVED PRIOR TO THE CONSTRUCTION OF ACCELERATION/DECELERATION, PASSING BLISTER LANES AND/OR LEFT TURN LANES. CONSTRUCTION OF THESE LANES INCLUDES BUT IS NOT LIMITED TO EXCAVATION, EMBANKMENT, PAVING, AND SUB-GRADE PREPARATION, ETC. SITE Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 0 0 1 - C o v e r S h e e t . d w g - Co v e r S h e e t Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 0 : 5 3 : 4 0 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 0 : 5 6 : 3 8 A M / Ke n n y M i t c h e l l SITE MAP SCALE: 1" =60' Map Unit: CrA - Crosby silt loam, 0 to 2 percent slopes CrA- Crosby silt loam, 0 to 2 percent slopes This is a somewhat poorly drained soil and has a seasonal high watertable at 0.5 to 2.0 ft. and is on rises on uplands. Slopes are 0 to 2 percent. The native vegetation is hardwoods. The surface layer is silt loam and has moderately low or moderate organic matter content (1.0 to 3.0 percent). Permeability is very slow (< 0.06 in/hr) in the most restrictive layer above 60 inches. Available water capacity is moderate (6.2 inches in the upper 60 inches).The pH of the surface layer in non-limed areas is 5.1 to 6.0. Droughtiness and wetness are management concerns for crop production. This soil responds well to tile drainage. Ill i n o i s S t r e e t Mallard Court HYATT PLACE Il l i n o i s S t r e e t BUILDING HEIGHT TWO STORY # OF EMPLOYEES NA SANITARY PLAN & PROFILESC500-C502 UTILITY CONTACTS: Carmel Sewer Department 760 3rd Avenue Southwest Carmel, Indiana 46032 Carmel Water Utilities 3450 West 131st Street Westfield, IN 46074 AT & T 5858 North College Avenue Indianapolis, Indiana 46220 Brighthouse Networks 3030 Roosevelt Avenue Indianapolis, Indiana 46218 Duke Energy 16475 Southpark Drive Westfield, Indiana 46074 Indianapolis Power & Light Company 3600 North Arlington Avenue Indianapolis, Indiana 46218 Vectren Energy 16000 Allisonville Road Noblesville, Indiana 46060 Map Unit: BR - Brookston silty clay loam Br - Brookston silty clay loam In a typical profile the surface layer is very dark gray-ish brown and very dark gray silty clay loam about 11 inches thick. The subsoil extends to a depth of 58 inches and is dark gray, gray, and grayish brown, mottled, firm clay loam and loam. The substratum, to a depth of 70 inches, is brown loam. In some places this soil is a silty clay loam to a depth of 40 inches. In some places the lower part of the subsoil is sandy loam, loamy sand, or sandy clay loam. Lighter colored material has been deposited on the original surface layer in a few areas. OPERATING AUTHORITY CITY OF CARMEL ONE CIVIC SQUARE CARMEL, INDIANA 46032 (317) 571-2441 SITE Me r i d i a n S t r e e t Me r i d i a n S t r e e t Spring Lake Estates LANDSCAPE PLANC900 HYATT PLACE A part of the Southwest corner of the East Half of the Northwest Quarter of Section 35, Township 18 North, Rang 3 East, Clay Township, Hamilton County, Indiana, more particularly described as follows: Beginning at the corner of said section corner; thence North 00 degrees 01 minutes 06 seconds West 206.50 feet; thence North 88 degrees 53 minutes 04 seconds East 400.25 feet; thence North 00 degrees 04 minutes 19 seconds East 140.00 feet; thence North 88 degrees 53 minutes 04 seconds East 50.01 feet; thence South 00 degrees 04 minutes 19 seconds West 346.51 feet; thence South 88 degrees 53 minutes 04 seconds West 449.93 feet to the place of beginning, containing 2.294 acres, more or less. DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               TO P O G R A P H I C A L S U R V E Y / D E M O P L A N C100 020 2010 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 1 0 0 - T o p o g r a p h i c a l S u r v e y . d w g - C1 0 0 - T o p o P l a n Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 8 : 3 1 : 0 4 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 0 : 5 7 : 2 9 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N Know what's R C.O. T T.P. M DYH E S x x T W P.W.P. STORM SEWER LINE; MANHOLE, CURB INLET, FLAT INLET & ENDSECTION GV CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. OVERHEAD ELECTRIC LINES TELEPHONE LINE WATER LINE SANITARY SEWER LINE; MANHOLE FENCE LINE POWER POLES LIGHT POLE SANITARY WET WELL GUY WIRE TELEPHONE PEDESTAL TELEPHONE MANHOLE GAS VALVE CLEANOUT WATER METER WATER VALVE FIRE HYDRANT DEMO ITEMS FOR WATER LOCATES CONTACT: CARMEL UTILITIES (317) 571-2648 FOR SANITARY SEWER LOCATES CONTACT: CLAY TOWNSHIP REGIONAL WASTE DISTRICT (317) 844-9200 UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. CONSTRUCTION LIMITS DEVELOPMENT SECTION LIMITS FLOOD STATEMENT THIS SITE DOES NOT LIE WITHIN A FLOODWAY OR FLOOD PLAIN PER FIRM 18057C0209G DATED NOV. 19, 2014. VEGETATIVE COVER EXISTING SITE CONSIST MOSTLY OF GRASS AND WEEDS WITH WOODS ON THE SITE. ADJACENT PROPERTIES NORTH: COMMERCIAL EAST: COMMERCIAL SOUTH: COMMERCIAL WEST: RESIDENTIAL DEMO ITEMS DEMO ITEMS DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               TO P O G R A P H I C A L S U R V E Y / D E M O P L A N C101 020 2010 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 1 0 0 - T o p o g r a p h i c a l S u r v e y . d w g - C1 0 1 - T o p o P l a n Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 8 : 3 1 : 0 4 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 0 : 5 7 : 3 2 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N Know what's R C.O. T T.P. M DYH E S x x T W P.W.P. STORM SEWER LINE; MANHOLE, CURB INLET, FLAT INLET & ENDSECTION GV CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. OVERHEAD ELECTRIC LINES TELEPHONE LINE WATER LINE SANITARY SEWER LINE; MANHOLE FENCE LINE POWER POLES LIGHT POLE SANITARY WET WELL GUY WIRE TELEPHONE PEDESTAL TELEPHONE MANHOLE GAS VALVE CLEANOUT WATER METER WATER VALVE FIRE HYDRANT DEMO ITEMS FOR WATER LOCATES CONTACT: CARMEL UTILITIES (317) 571-2648 FOR SANITARY SEWER LOCATES CONTACT: CLAY TOWNSHIP REGIONAL WASTE DISTRICT (317) 844-9200 UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. CONSTRUCTION LIMITS DEVELOPMENT SECTION LIMITS FLOOD STATEMENT THIS SITE DOES NOT LIE WITHIN A FLOODWAY OR FLOOD PLAIN PER FIRM 18057C0209G DATED NOV. 19, 2014. VEGETATIVE COVER EXISTING SITE CONSIST MOSTLY OF GRASS AND WEEDS WITH WOODS ON THE SITE. ADJACENT PROPERTIES NORTH: COMMERCIAL EAST: COMMERCIAL SOUTH: COMMERCIAL WEST: RESIDENTIAL DEMO ITEMS DEMO ITEMS DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               TO P O G R A P H I C A L S U R V E Y / D E M O P L A N C102 020 2010 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 1 0 0 - T o p o g r a p h i c a l S u r v e y . d w g - C1 0 2 - T o p o P l a n Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 8 : 3 1 : 0 4 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 0 : 5 7 : 3 4 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N Know what's R C.O. T T.P. M DYH E S x x T W P.W.P. STORM SEWER LINE; MANHOLE, CURB INLET, FLAT INLET & ENDSECTION GV CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. OVERHEAD ELECTRIC LINES TELEPHONE LINE WATER LINE SANITARY SEWER LINE; MANHOLE FENCE LINE POWER POLES LIGHT POLE SANITARY WET WELL GUY WIRE TELEPHONE PEDESTAL TELEPHONE MANHOLE GAS VALVE CLEANOUT WATER METER WATER VALVE FIRE HYDRANT DEMO ITEMS FOR WATER LOCATES CONTACT: CARMEL UTILITIES (317) 571-2648 FOR SANITARY SEWER LOCATES CONTACT: CLAY TOWNSHIP REGIONAL WASTE DISTRICT (317) 844-9200 UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. CONSTRUCTION LIMITS DEVELOPMENT SECTION LIMITS FLOOD STATEMENT THIS SITE DOES NOT LIE WITHIN A FLOODWAY OR FLOOD PLAIN PER FIRM 18057C0209G DATED NOV. 19, 2014. VEGETATIVE COVER EXISTING SITE CONSIST MOSTLY OF GRASS AND WEEDS WITH WOODS ON THE SITE. ADJACENT PROPERTIES NORTH: COMMERCIAL EAST: COMMERCIAL SOUTH: COMMERCIAL WEST: RESIDENTIAL DEMO ITEMS DEMO ITEMS DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               SI T E P L A N C200 A B C D E F G H J K L M 6" COMBINED CURB AND WALK ACCESSIBLE RAMP LAWN AREA (SEE LANDSCAPE PLAN) 4" WIDE WHITE STRIPING 6" STRAIGHT CURB CONCRETE BOLLARD 4" WIDE BLUE STRIPING DUMPSTER ENCLOSURE HANDICAP SIGN DECORATIVE ENTRY (SEE ARCH. PLANS) HANDICAP PARKING 1' CONCRETE MEDIAN (SEE ARCH. PLANS) KEYNOTES BUILDING LINE DRAINAGE EASEMENT RADIUS PROPOSED CONCRETE B.L. D.E. R= EXISTING SANITARY SEWER EXISTING STORM SEWER PROPOSED SANITARY LATERAL PROPOSED STORM SEWER PROPOSED WATER LATERAL S LEGEND 020 2010 NOTES ALL CONCRETE CURB RADII ARE 5' TO FACE OF CURB UNLESS NOTED OTHERWISE. ALL RADII AND PAVEMENT DIMENSIONS ARE MEASURED TO THE EDGE OF PAVEMENT OR FACE OF CURB (WHERE APPLICABLE) SEE ARCHITECTURAL PLANS FOR BUILDING DIMENSIONS ALL DIMENSIONS TO THE BUILDING ARE TO THE BUILDING FACE AT GRADE. CONTRACTOR SHALL COORDINATE WITH THE BUILDING CONTRACTOR ON PLACING THE FINAL ASPHALT WEARING SURFACE ON ALL PAVED AREAS. TIMING SHALL BE COORDINATED TO MINIMIZE CONSTRUCTION-TYPE TRAFFIC ON THE FINAL WEARING SURFACE. ALL SOFT SPOTS IN PAVEMENT AND SUBGRADE TO BE REPAIRED PRIOR TO PLACEMENT OF FINAL ASPHALT SURFACE. 1. 2. 3. 4. 5. HYATT PLACE ITEM PROVIDED PER THE SUBMITTED SITE DEVELOPMENT PLAN PARKING SPACES REQUIRED/MOBILITY IMPAIRED ACCESSIBLE SPACES 87 SPACES TOTAL (4 H.C. SPACES) CONCRETE PARKING BUMPER CONCRETE SIDEWALK SEE SHEET C803 FOR PAVEMENT SPECS MONUMENT SIGN RETAINING WALL FIRE DEPT. CONNECTION N O P Q R S 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 2 0 0 - S i t e P l a n . d w g - C2 0 0 - S i t e P l a n Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 8 : 4 5 : 4 8 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 0 : 5 9 : 4 7 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N CONSTRUCTION LIMITS DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               GR A D I N G P L A N C201 020 2010 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 2 0 1 - G r a d i n g P l a n . d w g - C2 0 1 - G r a d i n g P l a n Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 9 : 0 6 : 2 8 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 1 : 0 6 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N 870 848.0 EXISTING CONTOUR EXISTING SANITARY SEWER EXISTING STORM SEWER PROPOSED GRADE PROPOSED CONTOUR PROPOSED SANITARY SEWER PROPOSED STORM SEWER 870 S LEGEND BUILDING LINE STORM SEWER EASEMENT RADIUS PROPOSED CONCRETE B.L. S.S.E. R= CONTACT: CARMEL UTILITIES (317) 571-2648 FOR WATER LOCATES FOR SANITARY SEWER LOCATES CONTACT: CLAY TOWNSHIP REGIONAL WASTE DISTRICT (317) 844-9200 STORM SEWER FOR THIS PROJECT WILL BE PRIVATE ALL STORM SEWERS WITHIN PUBLIC RIGHT-OF-WAY SHALL BE RCP CLASS III. WITH EXCEPTION OF REAR YARD SSD'S. NOTE: FOR STORM AND PIPE CHARTS SEE THIS SHEET NOTES TO CONTRACTOR: ALL PADS SHOULD BE TESTED TO ASSURE A COMPACTION OF AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY USING THE STANDARD PROCTOR TEST METHOD. ANY PRIVATE TILES LOCATED ON THIS SITE WILL NEED TO BE LOCATED; BREATHERS SET AT THE DOWNSTREAM PROPERTY LINE AND CRUSHED OR REMOVED ACROSS THIS SITE. IF ANY OF THESE TILES EXTEND BEYOND THE LIMITS OF THIS PROJECT, THEY WILL NEED TO BE PROVIDED A POSITIVE OUTLET AND ALLOWED TO CONTINUE TO FUNCTION, AS IT IS ILLEGAL TO BLOCK OFF A PRIVATE "MUTUAL" TILE. CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF WORK TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY R/W. EXISTING PAVEMENT TO BE SAW CUT TO A CLEAN EDGE ADJACENT TO ANY WIDENING, AUXILIARY LANES, ETC. NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. CONSTRUCTION LIMITS FLUSH CURB DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               C300 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 3 0 0 - S t o r m W a t e r P o l l . & P r e v . P l a n . d w g - C3 0 0 Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 9 : 3 1 : 1 6 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 2 : 2 1 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N Know what's R 1" = 20 FT PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL: RAVI PATEL PHONE: (317) 357-8236 NOTE: 1.ANY ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED IN THE FIELD BY THE INSPECTOR. 2.IF SITE REMAINS INACTIVE FOR A PERIOD OF 2 WEEKS, THEN STABILIZATION IS REQUIRED TO TAKE PLACE IN THE FORM OF TEMPORARY SEEDING, MULCH, OR SPRAY ON POLYMER. NO EARTH DISTURBING ACTIVITIES MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. ANY DISCHARGE OF CONTAMINATED WATER DUE TO DEWATERING SHALL OUTLET THROUGH EXISTING VEGETATION OR FILTER BAGS THAT WILL NOT ADVERSELY IMPACT STORM WATER QUALITY. LEGEND Denotes Silt Fence, Tree Protection Fencing to also be installed in addition to Silt Fence. Denotes Construction Limits Temporary "Coconut Fiber Mat" or Below Grade " Drop Inlet Protection Basket" Seeding rate: Seeding mixture: 50#/acre 100% perennial rye SF SF SF Temporary "Drop inlet protection basket", Sediment Control Devices VEGETATIVE SWALE 2' SUMP WITH SNOUT Do Not Mow Sign DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               C301 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 3 0 0 - S t o r m W a t e r P o l l . & P r e v . P l a n . d w g - C3 0 1 Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 9 : 3 1 : 1 6 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 2 : 2 4 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL: RAVI PATEL PHONE: (317) 357-8236 Know what's R 1" = 50 FT LEGEND Denotes Construction Limits Denotes permanent seeding & mulch areas Seeding rate: Seeding mixture: l30#/acre or 3#/l000 S.F. 25% creeping red fescue 35% perennial rye 40% Kentucky bluegrass Denotes seeding w/fiber blanket #S150 by North American Green Seeding rate: Seeding mixture: ll0#/acre or 2.5#/l000 S.F. 38% Kentucky 3l fescue l9% perennial rye l9% annual rye l4% orchard grass l0% Kentucky bluegrass Denotes temporary seeding & mulching. Seeding rate: Seeding mixture: 50#/acre 100% perennial rye NOTE: 1.ANY ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED IN THE FIELD BY THE INSPECTOR. 2.IF SITE REMAINS INACTIVE FOR A PERIOD OF 2 WEEKS, THEN STABILIZATION IS REQUIRED TO TAKE PLACE IN THE FORM OF TEMPORARY SEEDING, MULCH, OR SPRAY ON POLYMER. NO EARTH DISTURBING ACTIVITIES MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. ANY DISCHARGE OF CONTAMINATED WATER DUE TO DEWATERING SHALL OUTLET THROUGH EXISTING VEGETATION OR FILTER BAGS THAT WILL NOT ADVERSELY IMPACT STORM WATER QUALITY. DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               C302 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 3 0 0 - S t o r m W a t e r P o l l . & P r e v . P l a n . d w g - C3 0 2 Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 9 : 3 1 : 1 6 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 2 : 2 5 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL: RAVI PATEL PHONE: (317) 357-8236 HYATT PLACE SITE NAME The area scheduled for construction is known as "Hyatt Place" (hereinafter referred to as the "Project"). PROJECT LOCATION The property is located at the east of Illinois Street and west of Meridian Street. /DWLWXGHž 1/RQJLWXGHž : OWNER'S INFORMATION 1.) WATERSHED HYDROLOGIC UNIT CODE (HUC) HUC14 05120201120070 Little Eagle Creek Drain 13.) MATERIAL HANDLING AND SPILL PREVENTION PLAN 2.) NAME OF ALL RECEIVING WATERS 3.) PEAK DISCHARGE FOR POST CONSTRUCTION CONDITIONS (10 year) Post-construction 10-year discharge: 1.360 cfs 4.) SPECIFIC POINTS WHERE STORMWATER DISCHARGE WILL LEAVE THIS SITE There should be no potential discharges into the groundwater on this site. 5.) LOCATIONS WHERE STORMWATER MAY BE DIRECTLY DISCHARGED INTO GROUNDWATER (abandoned wills or sinkholes) 6.) SOILS MAP WITH DESCRIPTIONS AND LIMITATIONS Soil information from the Hamilton County Soil Survey is shown on sheet C304. This includes a copy of the soil map, descriptions of the soils and a description of how this site will accommodate existing soil limitations. 7.) DESCRIPTION OF POTENTIAL POLLUTANT SOURCES ASSOCIATED WITH CONSTRUCTION ACTIVITIES The following potential pollutant sources may be associated with construction activities on site: 1. Material storage areas (more specifically described below) 2. Construction waste material 3. Fuel storage areas and fueling stations 4. Exposed soils 5. Leaking vehicles and equipment 6. Sanitary waste from temporary toilet facilities 7. Litter 8. Windblown dust 9. Soil tracking off site from construction equipment The following construction materials will be staged or stored on site at various points during development of the site. 1. Road base 2. Concrete drainage pipe 3. Concrete culverts 4. Precast concrete manholes Silt fences shall be installed with the contour of the slopes. Max. Slope Length above Silt Fence (Ft.) Land Slope % 100 75 50 25 15 < 2 2-15 5-10 10-20 7-20 8.) TEMPORARY AND PERMANENT STORMWATER QUALITY MEASURES b. For dimensions of these measures see sheets C304. d. For Construction details for these measures see sheet 304. a. Construction entrance will be in place prior to this phase of construction. Entrance is shown for reference on Sheet C300 and C301. The contractor has the option to use one of several storm sewer inlet protection methods, depending on the inlet location and the stage of construction. Refer to Sheet C301 for locations and refer to Sheet C304 for details. Manufactured products such as the Dandy Bag or Catch-All products may also be used at the contractor's discretion. Manufactured products shall be installed in accordance with the manufacturer's specifications. c. Proposed detention basins shall be used to extend detention times to achieve stormwater quality. Riprap revetment will be used at each of the stormwater outlets where not connecting into existing manholes. Erosion control blankets will be utilized as grade-stabilization structures. Sheet flow areas will be protected by seed and mulch or hydroseeding. Erosion control blankets will be installed on sloped areas where the slope exceeds 6:1 (horizontal to vertical). Silt fencing will be utilized to minimize runoff from construction areas as identified on Sheets C300-C301. e. Monitoring and maintenance guidelines: 9.) GENERAL CONSTRUCTION SEQUENCE Temporary stockpile shown on sheet C301. 10.) LOCATION OF PROPOSED SOIL STOCKPILES, BORROW, AND/OR DISPOSAL AREAS 11.) TEMPORARY AND PERMANENT SURFACE STABILIZATION METHODS APPROPRIATE FOR EACH SEASON Refer to Sheet C304, within the Seasonal Soil Protection Chart. 12.) EROSION AND SEDIMENT CONTROL SPECIFICATIONS FOR INDIVIDUAL BUILDING LOTS 14.) OPERATOR'S INFORMATION SWPPP FOR CONSTRUCTION SITES SWPPP FOR POST-CONSTRUCTION 1.) DESCRIPTION OF POLLUTANTS AND THEIR SOURCES ASSOCIATED WITH THE PROPOSED LAND USE Solid Waste Disposal No solid material, including building materials, is permitted to be discharged to surface waters or buried on site. All solid waste materials, including disposable materials incidental to the construction activity, must be collected in containers or closed dumpsters. The collection containers must be emptied periodically and the collected material hauled to a landfill permitted by the State and/or appropriate local municipality to accept the waste for disposal. Dumpsters and A foreman or supervisor should be designated in writing to oversee, enforce, and instruct construction workers on proper solid waste procedures. Hazardous Waste Whenever possible, minimize the use of hazardous materials and generation of hazardous wastes. All hazardous waste materials will be disposed in the manner specified by federal, state, or local regulations or by the manufacturer. Use containment berms in fueling and maintenance areas and where potential for spills is high. A foreman or supervisor should be designated in writing to oversee, enforce and instruct construction workers on proper hazardous waste procedures. The location of any hazardous waste storage areas should be indicated on the stormwater pollution prevention plan by the operator following on-site location of the facility. port-o-lets are not to be placed in the street. Dust Control/Off-site Vehicle Tracking During construction, water trucks should be used, as needed, by each contractor or subcontractor to reduce dust. After construction, the site should be stabilized to reduce dust. Construction traffic should enter and exit the site at a Construction Entrance with a rock pad or equivalent device. The purpose of the rock pad is to minimize the amount of soil and mud that is tracked into existing streets. If sediment escapes the construction site, off-site accumulations of sediment must be removed at a frequency sufficient to minimize offsite impacts. Inspection Schedule/Reporting All impacted areas, as well as all erosion and sediment control devices, will be inspected every seven (7) calendar days and within 24 hours after a rainfall of 0.5 inch or greater until an NOT is issued. Inspection reports after rain events are to be submitted to the City of Carmel Engineering Inspections shall be conducted and a written report prepared, by a designated and qualified person familiar with the USEPA NPDES Storm Water General Permit, and the Project. Inspection reports shall be completed including scope of the inspection, name(s) and qualifications of personnel making the inspection, the date of the inspection, observations relating to the implementation of the SWPPP, and any actions taken as a result of incidents of noncompliance noted during the inspection. The inspection report should state whether the site was in compliance or identify any incidents of noncompliance. The contractor shall keep a copy of the inspection reports on site and permanently for a period of two years following construction. The on-site reports may be requested by inspections conducted by the local MS-4. Construction Entrance Locations where vehicles exit the site shall be inspected for evidence of off-site sediment tracking. Each contractor and subcontractor shall be responsible for maintaining the Construction Entrance and other controls. Material Storage Inspections Inspectors must evaluate areas used for storage of materials that are exposed to precipitation. The purpose is to ensure that materials are protected and/or impounded so that pollutants cannot discharge from storage areas. Off-site material storage areas used solely by the subject project are considered to be part of the project and must be included in the erosion control plans and the site inspection reports. Soil Stabilization Inspections Erosion and Sediment Control Inspections All controls should be inspected at least once every seven (7) calendar days and following any storm event of 0.5 inch or greater. The following is a list of inspection/maintenance practices that will be used for specific controls: 1. Geotextiles/Erosion Control Mats: Missing or loose matting must be replaced or re-anchored. 2. Curb Inlet Protection shall be cleaned at least once per week and after every 0.5 inch rainfall event. 3. Mulching: Inspected for thin or bare spots caused by natural decomposition or weather-related events. Mulch in high traffic area should be replaced on a regular basis to maintain uniform protection. 4. Silt Fence: Removal of built-up sediment will occur when the sediment reaches one-third the height of the fence. 5. Stabilized Construction Entrance: Periodic regrading and top dressing with additional stones. 6. Vegetation: Protect newly seeded areas from excessive runoff and traffic until vegetation is established. Establish a watering and fertilizing schedule. 7. Good Housekeeping: Litter, construction debris, and construction chemicals exposed to stormwater shall be prevented from becoming a pollutant source for stormwater discharges through screening of outfalls and daily pickup of litter. In the event that sediment escapes the construction site, off-site accumulations of sediment must be removed at a frequency sufficient to minimize adverse impacts. An example of this may be the situation where sediment has washed into the street and could be carried into the storm sewers by the next rainfall and/or pose a safety hazard to users of public streets. Material Handling and Spill Prevention Discharge of hazardous substances or oil into stormwater is subject to reporting requirements. In the event of a spill of a hazardous substance, the operator is required to notify the National Response Center (1-800-424-8802) to properly report the spill. In addition, the operator shall submit a written description of the release (including the type and amount of material released, the date of the release, the circumstances of the release, and the steps to be taken to prevent future spills) to the local MS-4. Compliance of the site with the General Construction Permit remains the responsibility of all operators that have submitted an NOI until such time as they have submitted a Notice of Termination (NOT). The permittee's authorization to discharge under the General Construction Permit terminates at midnight of the day the NOT is signed. All permittees must submit an NOT within thirty (30) days after one or more of the following conditions have been met: 1. Final stabilization has been achieved on all portions of the site for which the permittee was responsible. 2. Another operator/permittee has assumed control over all areas of the site that have not been finally stabilized. 3. In residential construction operations, temporary stabilization has been completed and the residence has been transferred to the homeowner. The proposed land use will consist of single family residential houses. The pollutants and sources of each pollutant normally expected from these types of land uses are listed below: Pollutant Source: Passenger vehicles, delivery vehicles, and trucks Type of Pollutant: Oil, gasoline, diesel fuel, any hydrocarbon associated with vehicular fuels and lubricants, grease, antifreeze, windshield cleaner solution, brake fluid, brake dust, rubber, glass, metal and plastic fragments, grit, road de-icing materials Pollutant Source: Residence Type of Pollutant: Cleaning solutions or solvents, leaks from HVAC equipment, grit from roof drainage, aggregate or rubber fragments from roofing system Pollutant Source: Trash dumpster Type of Pollutant: Cleaning solutions or solvents, litter (paper, plastic, general refuse associated with distributions operations), uneaten food products, bacteria Pollutant Source: Roadway Type of Pollutant: Any pollutant associated with vehicular sources, grit from asphalt wearing surface, bituminous compounds from periodic maintenance (sealing, resurfacing and patching), pavement de-icing materials, paint fragments from parking stall stripes, concrete fragments, wind-blown litter from off-site sources, and elevated water temperatures from contact with impervious surfaces Pollutant Source: Lawn and landscape areas Type of Pollutant: Fertilizers, soil, organic material (leaves, mulch, grass clippings) and pesticides The anticipated pollution sources are the vehicles that will use these future facilities, including both truck and passenger vehicle traffic. Possible pollutants include oil, gasoline, antifreeze and other pollutants associated with vehicular traffic. Department One, Civic Square, attention Storm Water Administrator. Seeded areas will be inspected to confirm that a healthy stand of vegetation is maintained. The site has achieved final stabilization once all proposed roads are covered with pavement. And the remainder of the site has a stand of vegetation with at least 70% of the background vegetation density. The density of 70% or greater must be maintained to be considered as stabilized. The operator or their representative will water, fertilize, and reseed disturbed areas as needed to achieve this goal. 10. Concrete wash-out 11. Groundwater Chemical oxygen demand and Iron. Spill Response Directions Discharge of hazardous substances or oil into stormwater is subject to reporting requirements. In the event of a spill of a hazardous substance, the operator is required to notify the National Response Center (1-800-424-8802) to properly report the spill. In addition, the operator shall submit a written description of the release (including the type and amount of material released, the date of the release, the circumstances of the release, and the steps to be taken to prevent future spills) to the local MS-4. In the event of small spills, please contact the construction supervisor. In the event of spills that require removal of soils or other materials, please contact the construction supervisor, developer, County Surveyor's Office and the Local Fire Department. In the event of spills that have potential groundwater or surface water contamination, please contact the construction supervisor, developer, County Surveyor's Office, Local Emergency Response, IDEM, and the City of Carmel Utility Department. Hamilton County Surveyor: 317-776-8495 Carmel Fire Department: 317-571-2600 IDEM: 317-356-2411 Carmel Utilities: 317-571-2645 Bear Creek; Little Eagle Creek Drain Local Emergency Response: 911 This project includes the construction of 27 lots. Tallyn's Ridge consists of approximately 18.50 acres. Construction will include pad grades for the buildings, associated roadways, landscaping, and drainage infrastructure. Storm Runoff will leave the site through a proposed storm pipe to the West and into a Swale to a pipe under Shelbourne Road to Little Eagle Creek Drain. SOHUM Development, LLC 7050 East 21st Street Indianapolis, IN 46219 Phone: (317) 357-8236 Contact Person: Ravi Patel 2.)Description of Proposed Post Construction Stormwater Quality Measures: For further information on Post Construction Storm Water Quality measures please see the O&M manual for this project. a.Inlets/Sump Catch Basins - The proposed inlets will prevent large debris such as paper, trash and construction material from entering the storm sewer. The sump catch basins (Str. #800, 803, 806 & 810) are storm structures constructed with a sump which serves as a sediment storage basin that can be accessed and cleaned out when necessary. The inlet castings are also stamped with an environmental protection stamp informing the public not to pollute the environment. Inlets and inlet castings specifications can be found on Sheets C802 & C803. b.Vegetated Swale - There is a vegetated swale located just east and south of the proposed building. This area is gently sloped and vegetated to allow filtratrion prior to entering the detention basin and the ultimate storm outlet for this project. Also see details in the O & M Manual for further information. c.Aqua-Swirl (AS-2) - Structure #805 will serve as a structural water quality unit. See details int the O&M Manual. 3.) SEQUENCE DESCRIBING STORMWATER QUALITY MEASURE IMPLEMENTATION: Please see construction sequence. Also the stormwater quality will be handled with a Catch Basins, Vegetated Swales and Aqua-Swirl such measures will be in conjunction with the projects Water Quality and O&M manual. 4.) STORMWATER QUALITY MEASURES TO BE IMPLEMENTED TO PREVENT OR MINIMIZE ADVERSE IMPACTS TO STREAM AND RIPARIAN HABITATS: Please see construction sequence. Also the stormwater quality will be handled with a Catch Basins, Vegetated Swales and Aqua-Swirl such measures will be in conjunction with the projects Water Quality and O&M manual. 5.) DESCRIPTION OF OPERATION AND MAINTENANCE GUIDELINES FOR ALL POST-CONSTRUCTION STORMWATER QUALITY MEASURES: Please see construction sequence. Also the stormwater quality will be handled with a Catch Basins, Vegetated Swales and Aqua-Swirl such measures will be in conjunction with the projects Water Quality and O&M manual. 1.THE CONTRACTOR SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE CITY OF CARMEL PRIOR TO ANY CONSTRUCTING ON THE SITE BEING STARTED. THE CONTRACTOR AND/OR DEVELOPER SHALL NOTIFY IDEM AND THE CITY OF CARMEL 48 HOURS PRIOR TO START OF CONSTRUCTION. 2.)2//2:,1*7+(5(48,5('35(&216758&7,210((7,1*7+(&2175$&7256+$//&216758&77+(³3267,1* ,1)250$7,21&(17(5´217+(1257+($676,'(2)7+(352326('&216758&7,21(175$1&(7+(/2&$7,212)7+( POSTING INFORMATION CENTER IS SHOWN ON SHEET C300&C301. THE POSTING INFORMATION CENTER IS THE LOCATION WHERE A COPY OF THE APPROVED IDEM RULE 5 PERMIT, APPROVED SWPP PLAN, SIGNED O&M MANUAL AND MAINTENANCE LOGS ARE TO BE LOCATED. THE CONTRACTOR SHALL PROCEED TO CONSTRUCT THE CONSTRUCTION ENTRANCE AFTER ALL POSTING REQUIREMENTS HAVE BEEN MET. 3.IMMEDIATELY FOLLOWING THE INSTALLATION OF THE CONSTRUCTION ENTRANCE, THE CONTRACTOR SHALL CONSTRUCT THE MAINTENANCE AND REFUELING AREA. PLEASE REFER TO THE MAINTENANCE AND REFUELING AREA DETAIL ON SHEET C305. 4.AFTER THE MAINTENANCE AND REFUELING AREA IS CONSTRUCTED, THE CONTRACTOR TO CONSTRUCT THE CONCRETE WASHOUT AREA PER THE SPECIFICATIONS ON SHEET C304. CONCRETE WASHOUT SHALL NOT BE REQUIRED IF CONCRETE TRUCK IS EQUIPPED WITH SELF-CONTAINED CHUTE SYSTEM, SIMILAR TO SYSTEM PROVIDED BY ENVIROGUARD, OR APPROVED EQUAL. 5.PRIOR TO ANY EARTH MOVING THE CONTRACTOR SHALL INSTALL ALL SILT FENCE AS SHOWN ON SHEET C300. THE DETAILS AND SPECIFICATIONS FOR SILT FENCE INSTALLATION ARE LOCATED ON SHEET C303. 6.THE CONTRACTOR SHALL PROTECT ALL EXISTING INLETS WITH DROP INLET PROTECTION BASKETS AND/OR FIBER MATS AS SHOWN ON SHEET C300. THE DETAILS AND SPECIFICATIONS FOR THE DROP INLET BASKETS AND FIBER MATS ON SHEET C303. 7.:+(17+(³(;,67,1*´6,7(&216758&7,21/,0,76$5(&203/(7(/<67$%,/,=('7+(&217$&7256+$// EXCAVATE THE DETENTION BASIN AND ASSOCIATED SWALES AND PLACE MATERIAL IN THE PROPOSED FILL AREAS AS SHOWN ON SHEETS C201. 8.IMMEDIATELY FOLLOWING THE INSTALLATION OF DETENTION BASIN AND ASSOCIATED SWALES THE CONTRACTOR IS TO INSTALL ALL EROSION CONTROL BLANKETS AND SEEDING IN THESE AREAS AS SHOWN ON SHEET C301. THE DETAILS AND SPECIFICATIONS CAN BE FOUND ON SHEET C304. 9.AFTER LAKES HAVE BEEN STABILIZED CONTRACTOR TO PROCEED TO GRADE THE SITE. THE MATERIAL TO GRADE THE SITE SHALL BE EXCAVATED PER THE PROPOSED CUT & FILLS AS SHOWN ON SHEET C201. 10.CONTRACTOR SHALL INSTALL PROPOSED STORM SEWERS. 11.THE PROPOSED STORM SEWER AND SANITARY SEWER SHALL BE INSTALLED CONCURRENTLY WITH EACH OTHER WHEN CROSSINGS ARE ENCOUNTERED. 12.THE CONTRACTOR SHALL PREPARE THE SUB-GRADE FOR THE PROPOSED ROAD SYSTEM. IF LIME STABILIZATION IS THE METHOD CHOSEN, DUST SHALL BE KEPT TO A MINIMUM. DUST SHALL BE REMOVED FROM THE CONSTRUCTION VEHICLES PRIOR TO LEAVING THE SITE. 13.CONTRACTOR SHALL INSTALL ALL CONCRETE CURB. 14.CONTRACTOR SHALL INSTALL WATER MAIN. THE TRENCH AREA SHALL BE SEEDED AND MULCHED IMMEDIATELY FOLLOWING THE INSTALLATION OF THE WATER MAIN. 15.CONTRACTOR SHALL HAVE ALL OTHER APPROPRIATE UTILITIES INSTALLED. IT IS ULTIMATELY THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT THE TRENCH AREA IS SEEDED AND MULCHED IMMEDIATELY FOLLOWING THE INSTALLATION OF EACH UTILITY. 16.CONTRACTOR SHALL INSTALL ALL ASPHALT PAVEMENT. 17.THE CONTRACTOR SHALL PERMANENT SEED ALL AREAS THAT ARE ILLUSTRATED ON SHEETS C302. THE SEED MIXTURE AND RATE CAN BE FOUND ON SHEET C302-C304. 18.THE CONTRACTOR SHALL SCHEDULE A SITE INSPECTION WITH THE CITY OF CARMEL TO ENSURE THAT THE SITE IS STABILIZED. AFTER THE INSPECTOR APPROVES THE SITE CONDITIONS THE CONTRACTOR SHALL REMOVE ALL TEMPORARY EROSION CONTROL PRACTICES. 19.THE POST-CONSTRUCTION EROSION CONTROL PRACTICES THEN BECOME THE RESPONSIBILITY OF THE DEVELOPER OF THIS PROJECT. 20.THE DEVELOPER OF THIS PROJECT SHALL CONTINUE TO MONITOR THIS SITE FOR GOOD HOUSE KEEPING ON THE POST-CONSTRUCTION BMP'S UNTIL A NOT IS FILED WITH IDEM. 21.THE O&M MANUAL FOR THIS PROJECT WILL REMAIN THE RESPONSIBILITY OF THE LAND OWNER OR ANY PREDECESSORS TO TAKE CLAIM OF THIS PROPERTY. SOHUM Development, LLC 7050 East 21st Street Indianapolis, IN 46219 Phone: (317) 357-8236 Contact Person: Ravi Patel CONSTRUCTION WASH OUT DUMPSTER (DOUBLE WALL) CONCRETE PORT-O-LET AREA FUEL OIL TANK ZZ DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               C303 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 3 0 0 - S t o r m W a t e r P o l l . & P r e v . P l a n . d w g - C3 0 3 Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 9 : 3 1 : 1 6 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 2 : 2 8 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL: RAVI PATEL PHONE: (317) 357-8236 DO NOT MOW SIGN DETAIL DO NOT MOW ORSPRAY SIGNS ARE REQUIRED ON BOTH SIDE LIMITS OF BIO SWALES. INCLUDE PLANTING SCHEDULE AND WHICH QUALIFIED NATIVE PLANTING PERSONNEL OR ORGANIZATION WILL BE INSTALLING OR CONSULTED FOR INSTALLATION. OUTLETS TO PONDS USED AS POST CONSTRUCTION WATER QUALITY BMP'S WILL NEED TO HAVE A DEDICATED EASEMENT AND BE RECORDED AS SUCH ON THE PLAT WITH A SPECIFIC DESCRIPTION, (i.e. SPECIFIC POND OUTLETS ARE TO BE PLANTED WITH A WET MESIC SEED MIX) THE END GOAL IS TO ENSURE THAT EVEN THROUGH A CHANGE OF LAND OWERSHIP; THE BMP WILL STILL BE RECORDED ON THE PLAT AND MAINTENANCE RESPONSIBILITY WILL TRANSFER. ALSO, SPECIFY THAT ANY MODIFICATION TO THIS WATER QUALITY BMP ON THE RECORDED PLAT WILL REQUIRE APPROVAL FROM THE PLANNING COMMISION AND THE CITY OF CARMEL - MS4. GATHER SPECIFIC MAINTENANCE PROCEDURE FOR THESE PLANTINGS AND FOR THE POND ITSELF, AND INCLUDE THEM IN THE OPERATIONS AND MAINTENANCE MANUAL FOR THIS PROJECT. STABILIZATION PRACTICE PERMANENT SEEDING DORMANT SEEDING SEEDING SODDING MULCHING JAN. FEB. MAR. APR. MAY JUN. JUL. AUG. SEPT. OCT. NOV. DEC. A *///////////* *///> B > B > E *////////* > F** *//////////////* > G > SEASONAL SOIL PROTECTION CHART MAINTENANCE 1. INSPECT THE DROP INLET PROTECTION AFTER EACH STORM EVENT, AND MAKE NEEDED REPAIRS IMMEDIATELY. 2. REMOVE SEDIMENT FROM THE POOL AREA TO ENSURE ADEQUATE RUNOFF STORAGE FOR THE NEXT RAIN. 3. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ALL BARRELS, CONSTRUCTION MATERIAL, AND SEDIMENT AND DISPOSE OF PROPERLY, GRADE THE DISTURBED AREA TO THE ELEVATION OF THE TOP OF THE INLET AND STABILIZE. #4 GAGE WIRE FILTER FABRIC YARD GRASS SILT PROTECTION FOR DITCH GRATE (NEENAH R-4342) CASTINGS. CASTING DEPOSIT REMOVED SEDIMENT WHERE IT WILL NOT ENTER STORM DRAINS. REMOVE SEDIMENT (BUT NOT BY FLUSHING) WHEN IT REACHES HALF THE HEIGHT OF THE BARRIER. INSPECT FREQUENTLY FOR DAMAGE BY VEHICULAR TRAFFIC, AND REPAIR IF NEEDED. AFTER ALL AREAS DRAINING TO THESE AREAS AFTER ALL AREAS DRAINING TO THESE AREAS REMOVAL OF SILT FENCE REMOVAL OF INLET PROTECTION ARE STABILIZED ARE STABILIZED INLET PROTECTION AFTER EACH INLET IS PLACED N/A N/A INSPECT AFTER EACH STORM EVENT. THE AREA, AND RE-LAY AND STAPLE THE BLANKET. DURING VEGETATIVE ESTABLISHMENT, INSPECT AFTER STORM EVENTS FOR ANY EROSION BELOW THE BLANKET. IF ANY AREA SHOWS EROSION, PULL BACK THAT PORTION OF THE BLANKET COVERING IT, ADD SOIL, RE-SEED AFTER VEGETATIVE ESTABLISHMENT, CHECK THE TREATED AREA PERIODICALLY. IF ADDITIONAL FERTILIZATION IS NEEDED TO GET A SATISFACTORY STAND, DO SO ACCORDING TO SOIL TEST IF VEGETATION FAILS TO GROW, CONSIDER SOIL TESTING TO DETERMINE ACIDITY OR NUTRIENT DEFICIENCY PROBLEMS. (CONTACT YOUR SWCD OR COOPERATIVE EXTENSION OFFICE FOR ASSISTANCE.) REPAIR DAMAGED, BARE, OR SPARSE OR PATCHY, BY FILLING ANY GULLIES, RE-FERTILIZING, OVER - OR RE- SEEDING AND MULCHING AFTER RE-PREPARING THE SEEDBED. INSPECT PERIODICALLY, ESPECIALLY STORM EVENTS, UNTIL THE STAND IS SUCCESSFULLY ESTABLISHED. (CHARACTERISTICS OF A SUCCESSFUL STAND INCLUDE: VIGOROUS DARK GREEN OR BLUISH-GREEN SEEDLINGS; UNIFORM DENSITY WITH NURSE PLANTS, LEGUMES, AND GRASSES WELL INTERMIXED; GREEN LEAVES; AND THE PERENNIALS REMAINING GREEN THROUGHOUT THE SUMMER, AT LEAST AT THE PLANT BASE.) PLAN TO ADD FERTILIZER THE FOLLOWING SEASON ACCORDING TO SOIL TEST RECOMMENDATIONS. IF NITROGEN DEFICIENCY IS APPARENT. (EXHIBIT 3.11-B SHOWS ONLY WHEAT/RYE FALL SEEDED.) INSPECT PERIODICALLY AFTER PLANTING TO SEE THAT VEGETATIVE STANDS ARE ADEQUATELY ESTABLISHED; RE- CHECK FOR EROSION DAMAGE AFTER STORM EVENTS AND REPAIR; RESEED AND MULCH IF NECESSARY. TOPDRESS FALL SEEDED WHEAT OR RYE SEEDINGS WITH 50 LBS./ACRE OF NITROGEN IN FEBRUARY OR MARCH NATURAL GROUND, REMOVE TEMPORARY SLOPE DRAINS, AND STABILIZE ALL DISTURBED AREAS. REMOVE SEDIMENT FROM TRAPS WHEN THEY ARE 50% FULL. WHEN THE WORK AREA HAS BEEN STABILIZED, REMOVE THE RIDGE, FILL THE CHANNEL TO BLEND WITH THE CHECK THE OUTLETS AND MAKE NECESSARY REPAIRS IMMEDIATELY. REMOVE SEDIMENT FROM THE CHANNEL AND REINFORCE THE RIDGE AS NEEDED. INSPECT WEEKLY AND FOLLOWING EACH STORM EVENT. AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE THE FENCE AND SEDIMENT DEPOSITS, BRING THE DISTURBED AREA TO GRADE, AND STABILIZE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE DEPOSITED SEDIMENT WHEN IT REACHES HALF THE HEIGHT OF THE FENCE AT ITS LOWEST POINT OR INSPECT THE SILT FENCE PERIODICALLY AND AFTER EACH STORM EVENT. IF FENCE FABRIC TEARS, STARTS TO DECOMPOSE, OR IN ANY WAY BECOMES INEFFECTIVE, REPLACE THE REPAIR ANY BROKEN ROAD PAVEMENT IMMEDIATELY. SWEEPING. FLUSHING SHOULD ONLY BE USED IF THE WATER IS CONVEYED INTO A SEDIMENT TRAP OR BASIN. INSPECT ENTRANCE PAD AND SEDIMENT DISPOSAL AREA WEEKLY AND AFTER STORM EVENTS OR HEAVY USE. IMMEDIATELY REMOVE MUD AND SEDIMENT TRACKED OR WASHED ONTO PUBLIC ROADS BY BRUSHING OR RESHAPE PAD AS NEEDED FOR DRAINAGE AND RUNOFF CONTROL. EROSION CONTROL MATTING AFTER FINISH GRADING PERMANENT SEEDING TEMPORARY SEEDING AFTER FINISH GRADING AFTER ROUGH GRADING RECOMMENDATIONS. SEED IF NECESSARY. TEMPORARY DIVERSIONS AFTER ROUGH GRADING SILT FENCE PRIOR TO CLEANING AND GRADING IS CAUSING THE FABRIC TO BULGE. AFFECTED PORTION IMMEDIATELY. INSTALLATION SEQUENCE STONE ENTRANCE EROSION CONTROL MEASURE PRIOR TO CLEANING AND GRADING EROSION CONTROL NOTES TOPDRESS WITH CLEAN STONE AS NEEDED. MAINTENANCE Rule 5 requires all disturbed areas likely to be idle for 15 day shall have surface stabilization applied. When weather conditions prevent rapid germination of grass, then 2t/ac mulch will be used to ensure ground stabilization requirements are met. A = KENTUCKY BLUE GRASS 40 lbs./AC.: CREEPING RED FESCUE 40 lbs./AC.: PLUS 2 TONS STRAW MULCH/AC. OR ADD ANNUAL RYEGRASS 20lbs>/AC. PLUS 2 TONS STRAW MULCH/AC. OR ADD ANNUAL RYEGRASS 30lbs>/AC. B = KENTUCKY BLUE GRASS 60 lbs./AC.: CREEPING RED FESCUE 60 lbs./AC.: C = SPRING OATS 3 BUSHEL/ACRE D = WHEAT OR RYE 2 BUSHEL/ACRE E = ANNUAL RYEGRASS 40 lbs./AC. (1 lb./1000 sq. ft.) F = SOD G = STRAW MULCH 2 TONS/ACRE-ANCHOR ALL MULCH BY CRIMPING OR *///* = IRRIGATION NEEDED DURING JUNE, JULY, AND/OR SEPT. ** = IRRIGATION NEEDED FOR 2 TO 3 WEEKS AFTER APPLYING SOD TACKIFYING Curb inlet protection mat Plastic washers on ties CURB INLET PROTECTION DETAIL NOT-TO-SCALE Plastic washers on ties Runoff accumulated sediments after every storm. Inspect and repair as needed, and remove any1. Seedbed Preparation for Permanent Seeding 1. Test soil to determine pH and nutrient levels. (Contact you county SWCD or Cooperative Extension office for assistance and soils information, including available testing services.) 2. If soil pH is unsuitable for the species to be seeded, apply lime according to test recommendations. 3. Fertilize as recommended by the soil test. If testing was not done, consider applying 400-600 lbs./acre of 12-0-12 analysis, or equivalent, fertilizer. Do not use phosphorous containing fertilizer (12-12-12) unless soil tests show a phosphorous deficency. 4. Till the soil to obtain a uniform seedbed, working the fertilizer and lime into the soil 2-4 in. deep with a disk or rake operated across the slope. SILT FENCE INSTALLATION & SPECIFICATIONS Curb Inlet Protection Mats The Mat is designed to be attached over the top of the curb inlet grate with plastic cable ties (75# strength Min.). The overall dimension of the mat shall allow for 2" beyond the water inlet perforations in the casting. The exception to this would be along the top where the grate shall be exposed to allow overflow during heavy storm events. The composite curb inlet protection mat shall be a machine-produced mat of 100% coconut fiber matrix incorporated into a permanent three-dimensional matting. There shall be 2 layers of matrix evenly distributed across the entire width of the matting. There shall be 4 layers of super heavy duty UV stabilized polypropylene net with 0.5"x0.5" openings and 2 layers ultra heavy duty UV stabilized dramatically corrugated(crimped) intermediate polypropylene netting with 0.5"x0.5" openings. The mat shall be stitched with UV stabilized polypropylene at 1.50" spacing. This device should be used in conjunction with other BMP's to maximize the efficiency of the erosion control plan. The mats are to be checked every two weeks and after every storm event for maintenance and/or repair and replacement. NOT-TO-SCALE CONSTRUCTION ENTRANCE DETAIL 20 150 8 TYPICAL FLAT/RECTANGULAR/ROLLED CURB INLET FILTER TYPICAL CURB BOX INLET FILTER TYPICAL ROUND INLET FILTER 2-PLY REPLACEABLE SEDIMENT BAGS WITH GEOTEXTILE FILTER FABRIC LIFT HANDLES STAINLESS STEEL CLAMPING BAND REAR CURB GUARD FLAP WITH MAGNETIC TIE-DOWNS INSTALLATION: 1. 2. REMOVE GRATE DROP FLEXSTORM INLET FILTER ONTO LOAD BEARING LIP OF CASTING OR CONCRETE STRUCTURE 3.REPLACE GRATE STANDARD 2" OVERFLOW AREA 11 GAUGE STEEL SUSPENSION SYSTEM CURB INLET SEDIMENT CONTROL DEVICE OR ACCEPTABLE DEVICE BY CITY OF CARMEL WITH IN PUBLIC RIGHT OF WAY NTS CONCRETE WASHOUT DETAIL NOT-TO-SCALE AROUND ENTIRE PERIMETER HAY BALES STACKED LINE ENTIRE WASHOUT WITH IMPERMEABLE POLY-LINER. H A Y B A L E S ST A C K E D 2 H I G H EXCAVATE 1.0' INTO GROUND ANCHOR PLASTIC LINING OVER TOP OF BALES WITH STAKES SIGN TO DESIGNATE AREA AS A WASHOUT FACILITY NOTE: FACILITY TO BE LOCATED AWAY FROM STREAMS, PONDS, OR OTHER DRAINAGE WAYS. 15.0' 12 . 0 ' LINE ENTIRE WASHOUT WITH IMPERMEABLE POLY-LINER. NOTE: CONCRETE WASHOUT SHALL NOT BE REQUIRED IF CONCRETE TRUCK IS EQUIPPED WITH SELF-CONTAINED CHUTE SYSTEM, SIMILAR TO SYSTEM PROVIDED BY ENVIROGUARD, OR APPROVED EQUAL. SOILS MAP SCALE: 1"1000' Map Unit: Br - Brookston silty clay loam Br--Brookston silty clay loam This poorly drained soil has a seasonal high watertable above the surface or within 1.0 ft. and is in depressions. Slopes are 0 to 2 percent. The native vegetation is water tolerant grasses and hardwoods. The surface layer is silty clay loam and has moderate or high organic matter content (2.0 to 5.0 percent). Permeability is moderately slow (0.2 to 0.6 in/hr) in the most restrictive layer above 60 inches. Available water capacity is high (10.0 inches in the upper 60 inches).The pH of the surface layer in non-limed areas is 6.1 to 7.3. This soil is hydric. Wetness is a management concern for crop production. This soil responds well to tile drainage. Map Unit: CrA - Crosby silt loam, 0 to 2 percent slopes CrA--Crosby silt loam, 0 to 2 percent slopes This is a somewhat poorly drained soil and has a seasonal high watertable at 0.5 to 2.0 ft. and is on rises on uplands. Slopes are 0 to 2 percent. The native vegetation is hardwoods. The surface layer is silt loam and has moderately low or moderate organic matter content (1.0 to 3.0 percent). Permeability is very slow (< 0.06 in/hr) in the most restrictive layer above 60 inches. Available water capacity is moderate (6.2 inches in the upper 60 inches).The pH of the surface layer in non-limed areas is 5.1 to 6.0. Droughtiness and wetness are management concerns for crop production. This soil responds well to tile drainage. Pn - Patton silty clay loam In a typical profile the surface layer is very dark gray and black silty clay loam about 12 inches thick. The subsoil is dark gray, olive gray and light olive gray, mottled, firm silty clay loam about 26 inches thick. The substratum, to a depth of 60 inches, is calcareous and is olive gray and gray silt loam and light silty clay loam. In some areas, the surface layer is less than 12 inches thick or the substratum is stratified loamy material. In some areas calcareous loam till is at a depth of less than 60 inches and part of the subsoil below a depth of 40 inches formed in glacial till. Many areas that are surrounded by eroded soils have an overwash of light colored soil material on the original surface layer. SITE DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               C304 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 3 0 0 - S t o r m W a t e r P o l l . & P r e v . P l a n . d w g - C3 0 4 Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 9 : 3 1 : 1 6 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 2 : 3 2 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL: RAVI PATEL PHONE: (317) 357-8236 PORT-O-LET SECTION "Z"-"Z" #53 STONE 6" MIN. 3:1 LINE WITH GEOTEXTILE WOVEN FABRIC FUELING & VEHICLE MAINTENANCE AREA NOT-TO-SCALE Z CONCRETE WASH OUT AREA CONSTRUCTION DUMPSTER FUEL OIL TANK (DOUBLE WALL) POSTING SIGN LOCATION ZZ CONCRETE WASH OUT AREA CONSTRUCTION DUMPSTER FUEL OIL TANK (DOUBLE WALL) POSTING SIGN LOCATION ZZ CONCRETE WASH OUT AREA CONSTRUCTION DUMPSTER FUEL OIL TANK (DOUBLE WALL) POSTING SIGN LOCATION ZZ CONCRETE WASH OUT AREA CONSTRUCTION DUMPSTER FUEL OIL TANK (DOUBLE WALL) POSTING SIGN LOCATION Z SECTION "Z"-"Z" #53 STONE 6" MIN. 3:1 LINE WITH GEOTEXTILE WOVEN FABRIC FUELING & VEHICLE MAINTENANCE AREA NOT-TO-SCALE 5'-0" 5'-0" 2'-0" 10'-0" 3'-0" RIP-RAP DETAIL 6"-8" RIP-RAP HANDLAID NOT-TO-SCALE OVER GEOTEXTILE FABRIC 1-1/2'1-1/2' 1 STAPLE PER SQ. YD.PER SQ. YD. 1-1/2 STAPLES PER SQ. YD. 2 STAPLES PER SQ. YD. 3.5 STAPLES FT. 150 200 250 100 50 25 75 225 275 A B C D A A B B 175 125 C C C C B B D 4:1 3:1 2:1 1:1 LOW MED/HIGH FLOW CHANNEL CHANNEL FLOW AND SHORELINESLOPE GRADIENT SL O P E L E N G T H STAPLE PATTERNS APPLY TO ALL NORTH AMERICAN GREEN EROSION CONTROL BLANKETS. STAPLE PATTERNS WILL VARY DEPENDING UPON SLOPE LENGTH, SLOPE GRADE, SOIL TYPE AND AVERAGE ANNUAL RAINFALL. 20" 2' 4'4' 3' 2' 4' 3' 3' 6'6' 3' 3' STAPLE PATTERN GUIDE EROSION CONTROL BLANKET BLANKET THE BLANKET BLANKET. BLANKET STAPLES/STAKES BLANKET PORT-O-LET DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               UT I L I T Y P L A N C400 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 4 0 0 - U t i l i t y P l a n . d w g - C4 0 0 - U t i l i t y P l a n Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 9 : 2 3 : 1 5 A M / km i t c h e l l Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 3 : 4 5 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N BUILDING LINE DRAINAGE UTILITY & STORM EASEMENT DRAINAGE EASEMENT UTILITY EASEMENT SANITARY SEWER EASEMENT B.L. D.U.&S.E. D.E. U.E. S.S.E. EXISTING SANITARY SEWER EXISTING STORM SEWER PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED WATER LINEW S LEGEND NOTE: ALL PROPOSED HYDRANTS PAINTED RED CONSTRUCTION LIMITS DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               SI G N A G E P L A N C401 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 4 0 1 - S i g n a g e a n d M O T P l a n . d w g - C4 0 1 - S i g n a g e P l a n Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 9 : 5 6 : 5 5 A M / jm c w h o r t e r Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 5 : 4 0 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N STOP BAR NOTES: 1.THERMOPLASTIC PAVEMENT MARKINGS ARE REQUIRED ON ASPHALT PAVEMENT WITHIN RIGHT-OF-WAY. EPOXY PAVEMENT MARKINGS ARE REQUIRED ON CONCRETE WITHIN RIGHT-OF-WAY. 2.UTILITY CONFLICTS (INCLUDING UTILITY POLES) MUST BE COMPLETELY RESOLVED PRIOR TO CONSTRUCTION OF ACCELERATION/DECELERATION, PASSING BLISTER LANES AND/OR LEFT TURN LANES. CONSTRUCTION OF THESE LANES INCLUDES BUT IS NOT LIMITED TO EXCAVATION, EMBANKMENT, PAVING, AND SUBGRADE PREPARATION, ETC. 3.ALL ROADS MUST BE BROUGHT BACK TO ORIGINAL OR BETTER CONDITION, INCLUDING BUT NOT LIMITED TO STRIPING, STONE SHOULDERS AND SIGNAGE. REPAIRS (i.e., STRIPING)SHALL COINCIDE WITH THE ADJOINING ROAD AT BOTH ENDS. 4.ALL TRAFFIC CONTROL SIGNS SHALL MEET CHAPTER 2D: GUIDE SIGNS-CONVENTIONAL ROADS OF THE MUTCD MANUAL 2009 EDITION. 5.ALL PAVEMENT MARKINGS SHALL CONFIRM TO THE APPLICABLE MUTCD STANDARDS. 6.GRINDING METHODS SHALL BE UTILIZED FOR ALL PAVEMENT MARKING REMOVALS ST O P STOP LEGEND STOP SIGN - 2 (R1-1) STREET LIGHT (LIGHTS TO MATCH EXISTING LIGHTS SPECS AND TYPE) STOP BAR HANDICAP SIGN HANDICAP SIGN ST O P STOP BAR NO LEFT TURN ADDED BELOW STOP SIGN HANDICAP SIGN ENTRY SIGN DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               SA N I T A R Y S E W E R P L A N & P R O F I L E C500 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 5 0 0 - S a n i t a r y P l a n a n d P r o f i l e . d w g - C5 0 0 - S a n i t a r y P l a n P r o f i l e Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 7 : 1 1 : 5 1 A M / jm c w h o r t e r Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 8 : 0 2 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N Know what's R 1" = 50 FT NOTE: ALL FINAL STRUCTURE GRADES ARE TO BE WITHIN PLUS OR MINUS ONE TENTH (O.1') OF A FOOT OF DESIGN GRADE, AND ARE TO BE ESTABLISHED UTILIZING 1-4" RISER RING, NO MORE NO LESS, ON EACH STRUCTURE. NO EARTH DISTURBING ACTIVITIES MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. MIN. SLOPES PER THE TEN STATE STANDARDS SHALL PREVAIL IN ALL CASES. THE EXTERIORS OF ALL MANHOLES NEED TO BE COATED PER CLAY TOWNSHIP REGIONAL WASTE STANDARDS. THERE ARE TO BE NO WATER VALVES OR MANHOLES WITHIN THE PAVEMENT, CURB, OR SIDEWALK WITH THE EXCEPTION OF CURB INLETS. INSTALL A TRACER WIRE WITH ALL MAINS AND SERVICE CONNECTIONS. FOR INSTALLATION OF STORM MAINS, WATER MAINS, SANITARY MAINS, WATER SERVICE LATERALS, SANITARY SERVICE LATERALS UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. REFER TO SHEET C500 FOR SANITARY TRENCH DETAIL WITHIN CITY RIGHT-OF-WAY. FULL DEPTH GRANULAR BACKFILL DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               SA N I T A R Y S E W E R P L A N & P R O F I L E C501 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 5 0 0 - S a n i t a r y P l a n a n d P r o f i l e . d w g - C5 0 1 - S a n i t a r y P l a n P r o f i l e Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 7 : 1 1 : 5 1 A M / jm c w h o r t e r Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 8 : 0 6 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N 1" = 50 FT NOTE: ALL FINAL STRUCTURE GRADES ARE TO BE WITHIN PLUS OR MINUS ONE TENTH (O.1') OF A FOOT OF DESIGN GRADE, AND ARE TO BE ESTABLISHED UTILIZING 1-4" RISER RING, NO MORE NO LESS, ON EACH STRUCTURE. NO EARTH DISTURBING ACTIVITIES MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. MIN. SLOPES PER THE TEN STATE STANDARDS SHALL PREVAIL IN ALL CASES. THE EXTERIORS OF ALL MANHOLES NEED TO BE COATED PER CLAY TOWNSHIP REGIONAL WASTE STANDARDS. THERE ARE TO BE NO WATER VALVES OR MANHOLES WITHIN THE PAVEMENT, CURB, OR SIDEWALK WITH THE EXCEPTION OF CURB INLETS. INSTALL A TRACER WIRE WITH ALL MAINS AND SERVICE CONNECTIONS. FOR INSTALLATION OF STORM MAINS, WATER MAINS, SANITARY MAINS, WATER SERVICE LATERALS, SANITARY SERVICE LATERALS UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. REFER TO SHEET C501 FOR SANITARY TRENCH DETAIL WITHIN CITY RIGHT-OF-WAY. FULL DEPTH GRANULAR BACKFILL DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               SA N I T A R Y S E W E R P L A N & P R O F I L E C502 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 5 0 0 - S a n i t a r y P l a n a n d P r o f i l e . d w g - C5 0 2 - S a n i t a r y P l a n P r o f i l e Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 7 : 1 1 : 5 1 A M / jm c w h o r t e r Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 8 : 0 9 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N Know what's R 1" = 50 FT NOTE: ALL FINAL STRUCTURE GRADES ARE TO BE WITHIN PLUS OR MINUS ONE TENTH (O.1') OF A FOOT OF DESIGN GRADE, AND ARE TO BE ESTABLISHED UTILIZING 1-4" RISER RING, NO MORE NO LESS, ON EACH STRUCTURE. NO EARTH DISTURBING ACTIVITIES MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. MIN. SLOPES PER THE TEN STATE STANDARDS SHALL PREVAIL IN ALL CASES. THE EXTERIORS OF ALL MANHOLES NEED TO BE COATED PER CLAY TOWNSHIP REGIONAL WASTE STANDARDS. THERE ARE TO BE NO WATER VALVES OR MANHOLES WITHIN THE PAVEMENT, CURB, OR SIDEWALK WITH THE EXCEPTION OF CURB INLETS. INSTALL A TRACER WIRE WITH ALL MAINS AND SERVICE CONNECTIONS. FOR INSTALLATION OF STORM MAINS, WATER MAINS, SANITARY MAINS, WATER SERVICE LATERALS, SANITARY SERVICE LATERALS UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. REFER TO SHEET C501 FOR SANITARY TRENCH DETAIL WITHIN CITY RIGHT-OF-WAY. FULL DEPTH GRANULAR BACKFILL DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               ST O R M S E W E R P L A N & P R O F I L E C600 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 6 0 0 - S t o r m P l a n a n d P r o f i l e . d w g - C6 0 0 - S t o r m P l a n P r o f i l e Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 7 : 1 9 : 1 2 A M / jm c w h o r t e r Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 8 : 5 5 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N Know what's R 1" = 50 FT STORM SEWER NOTE THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OR CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS AND 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS. AND AS APPROVED BY THE CITY OF CARMEL. FULL DEPTH GRANULAR BACKFILL CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. NOTES: ALL STORM STRUCTURES TO RECEIVE SOLID LID CASTINGS ARE TO BE CONSTRUCTED TO PROVIDE ONE 4" RISER RING NO MORE, NO LESS TO ACHIEVE PLAN RIM GRADE. ALL YARD INLETS ARE TO BE CONSTRUCTED AT A TOLERANCE OF +0.00' TO -0.20' OF PLAN GRADE. ALL STORM SEWER CASTINGS SHALL BE LABELED "DUMP NO WASTE-DRAINS TO WATERWAY" ALL SSD'S (SUBSURFACE DRAINS) WILL NEED TO BE DOUBLE WALL SMOOTH BORE PERFORATED (HDPE) PIPE. DEBRIS GUARDS ARE TO BE INSTALLED ON ALL OPEN ENDED INLETS. FOR STORM STRUCTURE SIZING AND CASTING TABLE SEE DETAIL D-18 ON SHEET C801. ALL STORM SEWERS WITHIN PUBLIC RIGHT-OF-WAY SHALL BE RCP CLASS III. FOR INSTALLATION OF STORM UNDER CITY STREETS AND COVER REQUIREMENTS, SEE SHEET No. C801 ON THE TRENCH DETAIL. ALL TOP OF CASTING ELEVATIONS FOR STORM SEWERS SHALL BE CONSTRUCTED WITH A 72/(5$1&(2))7“ MINIMUM COVER FOR PIPE CROSSINGS OF CITY STREETS: THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION, THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1'-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. STORM SYSTEM WITH THE EXCEPTION OF REAR YARD SSDs, STORM SEWERS FOR THIS DEVELOPMENT WILL BE PUBLIC. DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               CO N S T R U C T I O N D E T A I L S C800 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 8 0 0 - C o n s t r u c t i o n D e t a i l s . d w g - C8 0 0 - C o n s t r u c t i o n D e t a i l s Mo d i f i e d / B y : No v e m b e r 1 9 , 2 0 1 5 6 : 0 2 : 5 4 P M / bh u f f Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 9 : 0 9 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               SA N I T A R Y S E W E R D E T A I L S C801 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 8 0 0 - C o n s t r u c t i o n D e t a i l s . d w g - C8 0 1 - C o n s t r u c t i o n D e t a i l s Mo d i f i e d / B y : No v e m b e r 1 9 , 2 0 1 5 6 : 0 2 : 5 4 P M / bh u f f Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 9 : 1 1 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N Aqua-Swirl Concentrator Model AS-2 Off-Line Horseshoe Standard DetailDate:11/06/08 Scale: Document: Drawn By: AS-2 STD 1:20 BLR 1. System shall be designed for the following capacities: Peak Treatment Flow: 1.1 cfs [31 L/s] 6HGLPHQW6WRUDJHIWñ>Pñ@ Oil/Debris Storage: 37 gal. [140 L] STANDARD NOTE: U.S. Patent No. 6524473 and other Patent Pending Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com Octagonal Base Plate Arched Baffle VentPipe coupling by Contractor. 12" [305 mm] long Stub-out by Manufacturer. Arched Baffle Varies Rim elevations to match finished grade. HDPE risers can be field cut by Contractor.Manhole Frame and Cover by Manufacturer. (See Detail) Undisturbed Soil Bedding Gravel Backfill 42.0021" [1067 mm] In l e t 42.0021" [1067 mm] 42.0021" [1067 mm] 8.6254" [219 mm] OD Max 32.0016" [813 mm] OD 38.0019" [965 mm] 60.0030" [1524 mm] 12.0006" [305 mm] ‘ >‘PP@ * Please see accompanied Aqua-Swirl specification notes. * See Site Plan for actual system orientation. 2ULHQWDWLRQPD\YDU\IURPƒƒRU custom angles to meet site conditions. Riser Vent Swirl Inlet Swirl Outlet 4 1/2" [114 mm] Concrete Gravel Backfill Place small amount ofconcrete to support and level manhole frame. DONOT allow manhole frameto rest upon HDPE riser. Soil 1/2" [13 mm] 1/2" [13 mm] Manhole Frame & Cover Detail NTS For Non-Traffic Areas Only Cover Frame Riser Concrete Gravel Backfill Soil 1/2" [13 mm] Bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Grade Rim 4 1/2" [114 mm] Gravel Backfill Paving 1/2" [13 mm] Manhole Frame & Cover Detail NTS For H-20 Traffic Loading Areas Cover Frame Riser 1/2" [13 mm] Concrete Gravel Backfill Paving 3" [76 mm] Typ. 10" [254 mm]Concrete 1/2" [13 mm] If traffic loading (H-20) is required or anticipated, a concrete pad must be placed over the entire Stormwater Treatment System. Sample details of concrete pad available upon request. Plan View Section A-A Gravel Backfill shall extend atleast 3.5 feet [1067 mm] outward from Swirl Concentrator and forthe full height of the Swirl Concentrator (including riser)extending laterally to undisturbed soils. (See MH Detail Below) Pipe coupling by Contractor. 12" [305 mm] long Stub-out by Manufacturer. 8.6254" [219 mm] OD Max Ou t l e t A A Document: Drawn By: Date: Scale: City, State - Project: #00000 Project Name Aqua-Swirl Concentrator Off-Line Horseshoe Box Layout 2705 Kanasita Drive, Chattanooga, TN 37343 Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com JCW 07/01/11 NTS AS Horseshoe Layout U.S. Patent No. 6524473 and other Patent Pending Aqua-Swirl Concentrator (by AquaShield, Inc.) DDDD24" (typ) Diversion Manhole (by Contractor) AA BB Inv el. C ‘&& Inv el. A Inv el. B EE EE FF GG Diversion Weir Top el. F Inv el. D In l e t Ou t l e t Inv el. C Storm Pipe (by Contractor) Pipe coupling and Connecting Pipe (by Contractor) Pipe coupling and Connecting Pipe (by Contractor) Flow Direction Grade (Rim) el. H Grade (Rim) el. G Inv el. E Storm Pipe (by Contractor) EE Storm Pipe (by Contractor) Inv el. J SoilSoil HDPE Swirl Chamber Swirl Chamber Top 30" Inner Diameter Riser ASTM D2321 Class II Crushed Stone Backfill with 90% Proctor Density ASTM D2321 Class 1 Crushed Stone Backfill with 95% Proctor Density 3" PavementRim Elevation to Match Finished Grade Manhole Frame and Cover Top Bars #5 Bars @ 4" Spacing Around Opening Bottom Bars (see table) SECTION TYPICAL DETAIL FOR TOP BARS FOR ALL CHAMBER SIZES PLAN (Slab # AS-4 - as shown; others - similar) HDPE Swirl Chamber Bottom Bars (see table) Top Bars # 5's @ 4" Spacing and 50" +/- Long No Contact Between HDPE Riser and Frame General Notes Concrete Properties * Air Entrained Concrete * Slump < 5 inch * Coarse Aggregate < 1 inch * Properly Cure Concrete for 5 Days * Compressive Strength at 28 Days - 3,000 p.s.i. * Concrete Cover 3 Inch for All Reinforcing Bar Reinforcing Properties * Reinforcing Bars ASTM A615 Grade 60 * Welded Wire Fabric (WWH) ASTM A185 Sheets Only Design Criteria * H-20 Loadings * Impact Factor - 30% Codes * ACI 318 Building Code for Reinforced Concrete * ASTM F1759 - Design of HDPE Chamber for Subsurface Application * ASTM D2321 - Crushed Stone Compaction Criteria Excavation * Slopes should be constructed in accordance with OSHA standards. Without any specific details of excavation depth and material type, excavation slopes should be no steeper than 2:1 (horizontal- vertical). If steeper slopes are desired, site specific information regarding excavation depth and/or desired slope heght should be forwarded to the Engineer. This detail is for bidding purposes only and should not be used for construction. Concrete pad must be designed by a PE using ASTM F-1759 in order to be H-20 Load Compatible. Description of Revision Detail for H-20 Loading Treatment System Aqua-Swirl Stormwater Typical Concrete/Pavement www.aquashieldinc.com Phone (888) 344-9044 Fax (423) 826-2112 U.S. Patent No. 6524473 Scale: Date: Drawn By: Document:Rev. DateCONCRETE/PAVEMENT JTD 12/20/06 1:40 4" O.C.E.W., Typ. 4" 1' Typ. 6' - 6 " ( s q u a r e ) 42" 12" 3 1/2" 3" 3" 4" Frame Depth Rebar Depths This is a Sample Detail, Please contact AquaShield, Inc. for more Information PAD STANDARD Slab Size Width (ft.) x Length (ft.) x Depth (in.) Standard Slab Sizes For AS-10 13 x 13 x 1211.1 Swirl Chamber Outer diameter (Ft.) 4.5 5.6 3.5 6.7 7.8 8.9 10.0 AS-6 AS-7 AS-8 AS-9 AS-3 AS-4 AS-5 11 x 11 x 12 12 x 12 x 12 8.5 x 8.5 x 12 10 x 10 x 12 6.5 x 6.5 x 10 7.5 x 7.5 x 10 6.5 x 6.5 x 13 AS Model # 6.3#9's Required Concrete Volume in Cubic Yards Bottom Required Rebar (6"O.C.) EachWay #8's #8's #7's #6's #6's #5's #5's 4.5 5.3 2.7 3.7 1.3 1.3 1.7 Covering Swirl Chambers 6"O.C.E.W., Typ. 1" Clear (Typ.) AS-12 15 x 15 x 1313.0 9.0#10's 2'-8" ‘2'-8" HDPE Manway ‘2'-8" OD 2.7AS-2 6.5 x 6.5 x 10 #5's 1.3 42" DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               ST O R M S E W E R D E T A I L S C801 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 8 0 0 - C o n s t r u c t i o n D e t a i l s . d w g - C8 0 2 - C o n s t r u c t i o n D e t a i l s Mo d i f i e d / B y : No v e m b e r 1 9 , 2 0 1 5 6 : 0 2 : 5 4 P M / bh u f f Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 9 : 1 6 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N ACCESSIBLE PARKING SIGN FOOTING. RECESS TAPE (BORDER) TYP. GREEN -ILLUMINATING FOOTING BELOW CONC. WALK 4" ALUMINUM SIGN WHITE -ILLUMINATING TAPE (BACKGROUND) GREEN -ILLUMINATING ‘; &21& NOT IN CONC. WALK TOP OF FOOTING IF PROVIDE 1" SLOPE AT TAPE (ARROW) 4X4 WOOD SIGN POST (PAINTED) (VAN ACCESSIBLE) BLUE -ILLUMINATING TAPE (SYMBOL BLOCK) TAPE (LETTERS) TYP. GREEN -ILLUMINATING METAL (SIGN) ALUMINUM 12" 6" 18" 42" 7' 18" 12' SIDEWALK FINISH ƒ81/(66 OTHERWISE INDICATED RUBBED FINISH TOP & FACE MEDIUM BROOM FINISH ACROSS DIRECTION OF TRAVEL UNLESS NOTED OTHERWISE 1" STEEL TROWEL FINISH OF CURB CONTROL JT. SEE DETAIL EXPANSION JT. SEE DETAIL 1" STEEL TROWEL FINISH TYPICAL PARKING STRIPING 8' MIN. FOR VANS8' MIN.5.0' MIN.8' MIN.9' (TYP.) 2'-0" O.C. 4" BLUE PAINTED PAVEMENT STRIPE (TYP.) 4" WHITE PAINTED PAVEMENT STRIPE 4" BLUE PAINTED PAVEMENT STRIPE CONC. WALK NOT-TO-SCALE NOT-TO-SCALE NOT-TO-SCALE DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               ST O R M S E W E R D E T A I L S C801 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 8 0 0 - C o n s t r u c t i o n D e t a i l s . d w g - C8 0 3 - C o n s t r u c t i o n D e t a i l s Mo d i f i e d / B y : No v e m b e r 1 9 , 2 0 1 5 6 : 0 2 : 5 4 P M / bh u f f Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 9 : 1 8 A M / Ke n n y M i t c h e l l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he Contractor shall be responsible for verifying that all state highways, city, and county permits have been obtained by the developer prior to start of construction. COMPACTED SUBGRADE 1.5" - 165#/SYD. HMA BITUMINOUS SURFACE 9.5mm ON 7" COMPACTED #53 BASE ON 3" - 330#/SYD. HMA BITUMINOUS TYPE 'B' BASE 25.0 mm ON 2" - 220#/SYD. HMA BITUMINOUS INTERMDEDIATE 19.0 mm ON ASPHALT ALTERNATIVE FOR COMMERCIAL DRIVE PER CITY STANDARDS MONOLETHIC CURB AND WALK CURB & WALK DETAIL NO SCALE SEE PLANS OF TOTAL THICKNESS OF SLAB @ 6-0" MAX. REBAR AND WELDED WIRE FABRIC SHOULD BE STOPPED 2" SHORT OF AN EXPANSION JOINT. @ 48'-0" MAX. AND @ ENDS OF RADII. SHALL HAVE 1/2" EXPANSION JOINTS CONSTRUCTION JOINTS SHALL BE CUT 1/4 DEPTH 18 " REBAR 3" 2 - #4 NOTES: 6"1. 2. 3. ƒ 3" 6" 2" RAD. 3" 6" CL R . CONTROL JOINT 6" AGGREGATE SIZE #53 4" OF COMPACTED 6x6 W1.4xW1.4xW.W.F. 1 1/2" 4" AS INDICATED ON THE DRAWINGS. PROVIDE A EXPANSION JOINT AT INTERSECTION WITH ANOTHER SIDEWALK, BETWEEN WALKS, BUILDINGS, 5. STORM STRUCTURES, AND AT SUCH OTHER POINTS EACH FINISHING OPERATON. 4. OF SIDEWALKS SHOULD BE HAND-TOOLED AFTER CONTROL JOINTS, EXPANSION JOINTS AND EDGES4" PAVEMENT 4" AGGREGATE SIZE #53 4" OF COMPACTED 1" PREFORMED JOINT FILLER WITH SEALER. NOT-TO-SCALE DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               LA N D S C A P E P L A N C900 020 2010 72978 HY A T T P L A C E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 11 / 2 0 / 1 5 Fi l e N a m e : S: \ 7 2 9 7 8 \ D W G \ C 9 0 0 - L a n d s c a p e P l a n . d w g - C9 0 0 - L a n d s c a p e P l a n Mo d i f i e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 0 : 5 0 : 0 0 A M / jm c w h o r t e r Pl o t t e d / B y : No v e m b e r 2 0 , 2 0 1 5 1 1 : 0 8 : 3 1 A M / Ke n n y M i t c h e l l AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N PLANT MATERIAL SCHEDULE KEY BOTANICAL NAME COMMON NAME QTY.SIZE REMARKS RO QUERCUS RUBRA NORTHERN RED OAK 8 TP LIRIODENDRON TULIPIFERA TULIP POPLAR TREE 20 NJT CEANOTHUS AMERICANUS NEW JERSEY TEA 55 BK BUXUS "GREEN VELVET"BOXWOOD GREEN VELVET 77 HY TAXUS X MEDIA HICKSI HICKS YEW 96 NOTE: ALL TREES TO BE NO LESS THAN 2 1 2" CALIPER IN SIZE. ALL TURF AREAS TO BE IRRIGATED. SOD AREAS