Loading...
HomeMy WebLinkAbout15120102 Building PlansE U R O P E A N I N F L U E N C E L L C 5 8 0 1 F o r e s t L a n e I n d i a n a p o l i s , I N 4 6 2 2 0 3 1 7 -4 1 8 -1 7 1 2 C o p y r i g h t 2 0 1 5 E u r o p e a n I n f l u e n c e L L C A l l r i g h t s r e s e r v e d s h a l l n o t b e c o p i e d o r a p p r o p r i a t e d . Revisions: File: LAYOUT - ARCH D SHEET 1 Date: 12/17/15 L A C K E Y R E S I D E N C E 1 0 7 5 7 T O R R E Y P I N E S C I R C L E SITE P LAN 1) GENERAL CONTRACTOR/BUILDER IS RESPONSIBLE FOR ANY AND ALL WORK PERFORMED ON THE EXISTING STRUCTURE. EXISTING MECHANICAL, ELECTRICAL AND STRUCTURAL SUITABILITY HAVE NOT BEEN DETERMINED FOR THE EXISTING STRUCTURE. 2) CODE COMPLIANCE ALL WORK IS TO COMPLY WITH THE LATEST ADOPTED VERSION OF THE INTERNATIONAL RESIDENTIAL CODE AND ANY APPLICABLE STATE, COUNTY, OR LOCAL REGULATIONS RESPONSIBILITY FOR CODE COMPLIANCE IS THE SOLE RESPONSIBILITY OF THE PURCHASER AND OR CONTRACTOR/BUILDER FOR THE PROJECT. 3) DIMENSIONS CONTRACTOR/BUILDER SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION WRITTEN DIMENSIONS TAKE RESIDENCE OVER SCALING. DO NOT SCALE THESE DRAWINGS ALL INTERIOR DIMENSIONS ARE TAKEN FROM STUD FACE. INTERIOR WALLS ARE NOMINAL 2X4 (3 1/2") UNLESS OTHERWISE NOTED. EXTERIOR WALLS ARE NOMINAL 2X4 PLUS SHEATHING (4") UNLESS OTHERWISE NOTED. ALL EXISTING DIMENSIONS, TO BE VERIFIED BY OWNER/CONTRACTOR PRIOR TO CONSTRUCTION. 4) STRUCTURAL & FRAMING MEMBERS ALL LIVE LOADS, DEAD LOADS, SNOW LOADS, WIND LOADS, AND LATERAL LOADS MUST BE CALCULATED BY THE CONTRACTOR/BUILDER BEFORE START OF CONSTRUCTION. FLOOR SYSTEMS INCLUDING ALL BEAMS, JOISTS, WALL SUPPORT, AND BLOCKING MUST BE REVIEWED BY A QUALIFIED STRUCTURAL ENGINEER. IT IS THE RESPONSIBILITY OF THE BUILDER/CONTRACTOR TO CONFIRM THE SIZE, SPACING AND GRADING OF ALL STRUCTURAL FRAMING MEMBERS. 5) MECHANICAL AND ELECTRICAL LAYOUTS ALL MECHANICAL AND ELECTRICAL LAYOUTS INCLUDED IN THIS PLAN ARE SUGGESTED ONLY. CONSULT WITH A QUALIFIED MECHANICAL AND ELECTRICAL CONTRACTOR FOR SPECIFIC SPECIFICATIONS, LOCATIONS AND SIZING. 6) SQUARE FOOTAGE FINISHED SQUARE FOOTAGE IS CALCULATED BASED ON MEASUREMENT TO THE OUTSIDE OF ALL EXTERIOR WALLS. ALL AREAS ARE COUNTED INCLUDING STAIRS, FIREPLACES INTERIOR WALL WIDTHS, MINOR "DEAD SPACES", ETC. BUILDING DATA ADDITION SQ FOOTAGE - 544 SQ FT TABLE OF CONTENTS P 1 - OVERVIEW, NOTES & SITE PLAN P 2 - ELEVATIONS P 3 - FOUNDATION PLAN P 4 - MAIN FLOOR PLAN P 5 - UPPER FLOOR PLAN, SECTIONS & ROOF PLAN P 6 - ELECTRICAL PLAN LEGAL DESCRIPTION LOT 16 CROOKED STICK ESTATES, SECTION ONE, IN HAMILTON COUNTY, INDIANA AS RECORDED IN PLAT BOOK 5, PAGES 149-151 IN THE OFFICE OF THE RECORDER OF HAMILTON COUNTY, INDIANA. STREED ADDRESS 10757 TORREY PINES CIRCLE3, CARMEL INDIANA 46032 EXISTING STRUCTURE 1x GUTTERBOARD & SOFFIT TO MATCH EXISTINGASPHALT SHINGLES TO MATCH EXISTING NEW ADDITION LIMESTONE WINDOW TRIM BRICK VENEER 1x GUTTERBOARD & SOFFIT TO MATCH EXISTING ASPHALT SHINGLES TO MATCH EXISTING NEW ADDITION BRICK VENEER NEW ADDITION BRICK VENEER STUCCO BOARD & CEDAR TRIM TO MATCH EXISTINGWROUGHT IRON RAILING BRICK VENEER EXISTING STRUCTURE BRICK VENEER ASPHALT SHINGLES TO MATCH EXISTING LIMESTONE WINDOW TRIM 1x GUTTERBOARD & SOFFIT TO MATCH EXISTING NEW ADDITION EXISTING STRUCTURE E U R O P E A N I N F L U E N C E L L C 5 8 0 1 F o r e s t L a n e I n d i a n a p o l i s , I N 4 6 2 2 0 3 1 7 -4 1 8 -1 7 1 2 C o p y r i g h t 2 0 1 5 E u r o p e a n I n f l u e n c e L L C A l l r i g h t s r e s e r v e d s h a l l n o t b e c o p i e d o r a p p r o p r i a t e d . Revisions: File: LAYOUT - ARCH D SHEET 2 Date: 12/17/15 Scale 1/4"=1' Scale 1/4"=1' L A C K E Y R E S I D E N C E 1 0 7 5 7 T O R R E Y P I N E S C I R C L EScale 1/4"=1'R IGHT ELEVATIONFRONT ELEVATIO N R EAR ELEVATION 2 6 6 826682668 2 6 6 8 2168 UP UP 7 ' 3 '-5 3 /1 6 " 2 1 ' 12'-4" 12'-4" 2 ' 2 2 '-4 " 2 ' 1 7 '-8 " 13'-10" STEP BRICK LEDGE AS REQD BY GRADE UTILITY UNFINISHED EXISTING CLOSET CRAWL CRAWL CRAWL INTEGRAL CONC LINTEL MIN 4" PEA FILL OVER VAPOR BARRIER 8" CONC CRAWL WALL MIN 4' HT STEP AS REQUIRED FOR GRADE 8X16 CONC FOOTER WITH 2 #2 REBAR CRAWL ONLY 60" x 32" ACCESS INTEGRAL CONC LINTEL 2 X 10 FJ 16" OC MIN 4" PEA FILL OVER VAPOR BARRIER 8" CONC CRAWL WALL MIN 4' HT STEP AS REQUIRED FOR GRADE 8X16 CONC FOOTER WITH 2 #2 REBAR CRAWL ONLY OVER EXISTING CONCRETE SLAB FOUNDATION INTEGRAL CONC LINTEL CRAWL ACCESS USE EXISTING WINDOW OPENING 2 X 10 FJ 16" OC EXISTING GARAGE FOUNDATION EXISTING BASEMENT FOUNDATION ADDED 4" STEEL COLUMN RECONFIGURED INTERIOR WALLS EXISTING INTERIOR WALLS EXISTING BASEMENT FOUNDATION EXISTING BATH STEP4" BRICK LEDGE STEP AS REQD BY GRADE NEW FOUNDATION WALL EXISTING FOUNDATION WALL EXISTING DECK FOUNDATION EXISTING BASEMENT FOUNDATION LVL E U R O P E A N I N F L U E N C E L L C 5 8 0 1 F o r e s t L a n e I n d i a n a p o l i s , I N 4 6 2 2 0 3 1 7 -4 1 8 -1 7 1 2 C o p y r i g h t 2 0 1 5 E u r o p e a n I n f l u e n c e L L C A l l r i g h t s r e s e r v e d s h a l l n o t b e c o p i e d o r a p p r o p r i a t e d . Revisions: File: LAYOUT - ARCH D SHEET 3 Date: 12/17/15 FO U N D ATIO N P LAN Scale 1/4"=1' NEW CRAWL SPACE AREA - 544 SQ FT L A C K E Y R E S I D E N C E 1 0 7 5 7 T O R R E Y P I N E S C I R C L E DN DN 2668 7674 ARCH 7 2 7 4 A R C H 7 2 7 4 A R C H 2 6 6 8 2 8 6 8 A R C H 2 6 6 8 2468 2468 4 0 6 8 3 6 7 4 A R C H 3 0 6 8 2 6 6 8 2 4 6 8 146830681468 1 6 0 7 0 1 6 0 7 0 2 6 6 8 2 8 6 8 3074 ARCH 2 8 6 8 5 0 8 0 4068 5 8 6 8 A R C H 3 6 6 8 A R C H 1 1 1 6 8 2 6 6 8 C O 2668 CO 2668 UP UP UP 8 ' C L G H T 1 1 ' C L G H T 1 1 ' C L G H T A1A1 B2B2 3 '-1 0 1 /2 " 5 '-5 " 8 '-8 " 8 '-8 " 13'-6"2'-9"9'-6"2'-9" 1 7 '-8 " 7 '-2 " 2 '-9 " 7'-8 5/8" 6 '-4 3 /8 " 7'-10 3/8" 6'-5 3/16" 9 '-2 " 7'-5 5/16" 8 '-1 3 /4 " 4 '-2 1 3 /1 6 " 2'-6 1/4"5'-2" 10'-10 1/8" 4 ' 2 ' - 5 " 4 '-4 " 6'-3 7/16" 2'-6 1/16" 3 '-6 5 /1 6 " 2 '-5 3 /1 6 " 2 1 '-3 " 2 1 '-3 1 /2 " 13'-6"14'-4" 1 4 ' 5 '-8 " 7 '-8 3 /8 " 2 3 '-1 3 /4 " 1 3 '-1 1 3 /4 " 2'6'-8"2' 7'7'-8" 5'-6"1'-11 1/2" 7'-9"12'-4" 4 '-1 0 " 4 '-6 " 6 '-7 " 12'-0 1/2"4'15'-5" 1 0 '-8 1 /2 " 1 0 ' 2'-9" 2'-6 3/4"9'-2 5/8"2'-6 5/8" 3 ' 1 7 ' GARAGE GARAGE LAUNDRY/ OFFICE DELETE EXISTING STAIRS & BALCONY TO 2ND FLOOR MASTER BDRM DINING OFFICE ADD STEP MASTER CLOSET FOYER SUN ROOM GREAT ROOM PANTRY BREAKFAST AREA MASTER BATH MASTER CLOSET KITCHEN DECK EXISTING FLATTEN CLG AT 12' 9' CLG HT 9' CLG HT B E V C E N T E R 11' CLG HT S E A T BATH LVL 9' CLG HT I C E 8 ' C L G H T 9 ' C L G H T 9' EXT WALL STEEL BEAM 4" STEEL COLUMN THROUGH TO BASEMENT BEAM 8' CLG HT 4" STEEL COLUMN RECONFIGURED INTERIOR WALLS EXISTING INTERIOR WALLS 8' CLG HT E U R O P E A N I N F L U E N C E L L C 5 8 0 1 F o r e s t L a n e I n d i a n a p o l i s , I N 4 6 2 2 0 3 1 7 -4 1 8 -1 7 1 2 C o p y r i g h t 2 0 1 5 E u r o p e a n I n f l u e n c e L L C A l l r i g h t s r e s e r v e d s h a l l n o t b e c o p i e d o r a p p r o p r i a t e d . Revisions: File: LAYOUT - ARCH D SHEET 4 Date: 12/17/15 M AIN L EV EL FLO O R P LAN Scale 1/4"=1' L A C K E Y R E S I D E N C E 1 0 7 5 7 T O R R E Y P I N E S C I R C L E DN DN 2 5 6 8 2668 2 6 6 8 2 6 6 8 2668 2668 6 0 6 8 5768 CO 4 0 6 8 2 6 6 8 5080 1 9 6 8 2 6 6 8 2 6 6 8 5 0 6 8 2 6 6 8 UPUP 4 '-8 1 /1 6 " 7 '-4 " 6 '-0 1 /2 " 12'-5" 7'-2 9/16"7'-0 3/16" 14'-0 15/16"9'-1 5/16" 3 '-6 " 4'-4"5'-10 3/4"4'-4" 1 3 '-9 3 /4 " 4 ' STEP 2' KNEE WALL GABLE WALL BEDROOM WROUGHT IRON RAILING HALL BEDROOM BONUS BEDROOM DECK BATH 2' KNEE WALL WALL OFF EXISTING DOOR ATTIC RAILING RECONFIGURED INTERIOR WALLS EXISTING INTERIOR WALLS DELETE EXISTING HALL WALLS 1 2 : 1 2 1 2 : 1 2 1 2 : 1 2 1 2 : 1 2 12 : 12 1 2 : 1 2 1 2 : 1 2 1 2 : 1 2 12 : 12 12 : 12 1 2 : 1 2 12 : 12 12 : 12 1 2 : 1 2 12 : 12 12 : 12 1 2 : 1 2 1 2 : 1 2 12 : 12 1 2 : 1 2 12 : 12 12 : 12 12 : 12 12 : 12 12 : 12 12 : 12 STEP 2' KNEE WALL GABLE WALL 2' KNEE WALL WALL OFF EXISTING DOOR RAILING DELETE EXISTING HALL WALLS EXISTING FLAT ROOF SECTION NEW ROOF SECTION NEW ROOF SECTION TYPICAL EXTERIOR WALL INSULATION VALUES EXTERIOR FILM R 0.17 STONE VENEER R 0.39 1" AIRSPACE R 1.01 1/2" SHEATHING R 0.62 FIBERGLASS INS.R 13.00 1/2" DRYWALL R 0.45 INTERIOR FILM R 0.68 TOTAL WALL SYST R 16.32 2 '-8 " 8 '-1 1 /8 " V A R I E S 2x10 FJ 16"OC 2 #4 STEEL REBAR CONTINUOUS 4" PERIMETER DRAIN IF SUMP REQUIRED 8" X 16" CONC FOOTING DAMP PROOFING GRADE WEEP HOLES 4' O.C. MASONRY FLASHING BRICK VENEER (MIN 1" AIR SPACE) 6" CONTINUOUS GUTTER 3/8 HARDY SOFFIT WITH CONTINUOUS SCREEN VENT SHINGLES & FELT PER SPEC OVER 7/16" OSB DECK 2 X 6 MIN RAFTERS 16" O.C. 1X6 FRIEZE 1/2" OSB SHEATHING WITH MOISTURE BARRIER TYP 8" GRAVEL BED OVER VAPOR BARRIER, SLOPE TO SUMP OR TIE INTO EXISTING FOUNDATION DRAIN 1X6 FACIA 2X10 C.J. R 38 CEILING INSULATION 2X4 STUDS WITH R13 INSULATION TYP 8" X 32" MIN BLOCK OR POURED CONCRETE WALLS FF E U R O P E A N I N F L U E N C E L L C 5 8 0 1 F o r e s t L a n e I n d i a n a p o l i s , I N 4 6 2 2 0 3 1 7 -4 1 8 -1 7 1 2 C o p y r i g h t 2 0 1 5 E u r o p e a n I n f l u e n c e L L C A l l r i g h t s r e s e r v e d s h a l l n o t b e c o p i e d o r a p p r o p r i a t e d . Revisions: File: LAYOUT - ARCH D SHEET 5 Date: 12/17/15 U P P ER LEVEL FL O O R P L AN Scale 1/4"=1' R OO F P LAN Scale 1/8"=1' L A C K E Y R E S I D E N C E 1 0 7 5 7 T O R R E Y P I N E S C I R C L E TYP ICAL WALL SECTION & R VALUES Scale 1/8"=1' WP R 4 GFCI 3WP SD EP DC SD DM A T AV Control C5/TVC5 TV T SP SP DESCRIPTIONSYMBOL ELECTRICAL - DATA - AUDIO LEGEND Ceiling Fan Ventilation Fans: Ceiling Mounted, Wall Mounted Ceiling Mounted Light Fixtures: Surface/Pendant, Recessed, Heat Lamp, Low Voltage Wall Mounted Light Fixtures: Flush Mounted, Wall Sconce Chandelier Light Fixture 240V Receptacle 110V Receptacles: Duplex, Weather Proof, GFCI Switches: Single Pole, Weather Proof, 3-Way, 4-Way Switches: Dimmer, Timer Audio Video: Control Panel, Switch Wall Jacks: CAT5, CAT5 + TV, TV/Cable Telephone Jack Intercom Thermostat Door Chime, Door Bell Button Smoke Detectors: Ceiling Mounted, Wall Mounted Electrical Breaker Panel Speakers: Ceiling Mounted, Wall Mounted Fluorescent Light Fixture DN DN UP UP UP RR RR GFCI GFCI R R R R RR RR RRR R R RR R RR R RR R R RR R R R R R R R R R R GFCI GFCI GFCI 3 GFCI 3 3 GFCI 3 GFCIGFCI GFCIGFCI 3 3 GFCI GFCI GFCIGFCI 3 3 3 GFCIUP TO LANDING RECESSED LIGHTS TIE TO EXISTING LIGHTS TIE TO EXISTING LIGHTS TIE TO EXISTING LIGHTS TIE TO EXISTING LIGHTS UP TO 2ND FLOOR SWITCH TO UNDERCOUNTER & IN CABINET LIGHTINGUSE UNDER CABINET STRIPS ON GFCI CITCUIT FOR ALL COUNTER OUTLETS TO EXISTING SWITCH TV OUTLET TV OUTLET TV OUTLET UNDER CABINET LIGHT DN DN UPUP R R R R R R 4 GFCI GFCI 4 GFCI 4 TO EXISTING EXT LIGHT DOWN TO LANDING RECESSED LIGHTS E U R O P E A N I N F L U E N C E L L C 5 8 0 1 F o r e s t L a n e I n d i a n a p o l i s , I N 4 6 2 2 0 3 1 7 -4 1 8 -1 7 1 2 C o p y r i g h t 2 0 1 5 E u r o p e a n I n f l u e n c e L L C A l l r i g h t s r e s e r v e d s h a l l n o t b e c o p i e d o r a p p r o p r i a t e d . Revisions: File: LAYOUT - ARCH D SHEET 6 Date: 12/17/15 Scale 3/16"=1' ELECTRICAL DIAGRAM - M AIN LEVEL NOTE EXISTING ELECTRICAL SWITCHES, OUTLETS AND LIGHTING IN NOT SHOWN AND WILL REMAIN UNCHANGE UNLESS NOTED ELECTRICAL DIAGRAM - UP PER LEVEL Scale 3/16"=1' L A C K E Y R E S I D E N C E 1 0 7 5 7 T O R R E Y P I N E S C I R C L E