SITE P LAN
1) GENERAL
CONTRACTOR/BUILDER IS RESPONSIBLE FOR ANY AND ALL WORK PERFORMED ON THE EXISTING STRUCTURE. EXISTING MECHANICAL, ELECTRICAL AND STRUCTURAL SUITABILITY HAVE NOT BEEN
DETERMINED FOR THE EXISTING STRUCTURE.
2) CODE COMPLIANCE
ALL WORK IS TO COMPLY WITH THE LATEST ADOPTED VERSION OF THE INTERNATIONAL RESIDENTIAL CODE AND ANY APPLICABLE STATE, COUNTY, OR LOCAL REGULATIONS
RESPONSIBILITY FOR CODE COMPLIANCE IS THE SOLE RESPONSIBILITY OF THE PURCHASER AND OR CONTRACTOR/BUILDER FOR THE PROJECT.
3) DIMENSIONS
CONTRACTOR/BUILDER SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION
WRITTEN DIMENSIONS TAKE RESIDENCE OVER SCALING. DO NOT SCALE THESE DRAWINGS
ALL INTERIOR DIMENSIONS ARE TAKEN FROM STUD FACE. INTERIOR WALLS ARE NOMINAL 2X4 (3 1/2") UNLESS OTHERWISE NOTED. EXTERIOR WALLS ARE NOMINAL 2X4 PLUS SHEATHING (4") UNLESS OTHERWISE
NOTED.
ALL EXISTING DIMENSIONS, TO BE VERIFIED BY OWNER/CONTRACTOR PRIOR TO CONSTRUCTION.
4) STRUCTURAL & FRAMING MEMBERS
ALL LIVE LOADS, DEAD LOADS, SNOW LOADS, WIND LOADS, AND LATERAL LOADS MUST BE CALCULATED BY THE CONTRACTOR/BUILDER BEFORE START OF CONSTRUCTION.
FLOOR SYSTEMS INCLUDING ALL BEAMS, JOISTS, WALL SUPPORT, AND BLOCKING MUST BE REVIEWED BY A QUALIFIED STRUCTURAL ENGINEER.
IT IS THE RESPONSIBILITY OF THE BUILDER/CONTRACTOR TO CONFIRM THE SIZE, SPACING AND GRADING OF ALL STRUCTURAL FRAMING MEMBERS.
5) MECHANICAL AND ELECTRICAL LAYOUTS
ALL MECHANICAL AND ELECTRICAL LAYOUTS INCLUDED IN THIS PLAN ARE SUGGESTED ONLY. CONSULT WITH A QUALIFIED MECHANICAL AND ELECTRICAL CONTRACTOR FOR SPECIFIC SPECIFICATIONS,
LOCATIONS AND SIZING.
6) SQUARE FOOTAGE
FINISHED SQUARE FOOTAGE IS CALCULATED BASED ON MEASUREMENT TO THE OUTSIDE OF ALL EXTERIOR WALLS. ALL AREAS ARE COUNTED INCLUDING STAIRS, FIREPLACES INTERIOR WALL WIDTHS, MINOR
"DEAD SPACES", ETC.
BUILDING DATA
ADDITION SQ FOOTAGE - 544 SQ FT
TABLE OF CONTENTS
P 1 - OVERVIEW, NOTES & SITE PLAN
P 2 - ELEVATIONS
P 3 - FOUNDATION PLAN
P 4 - MAIN FLOOR PLAN
P 5 - UPPER FLOOR PLAN, SECTIONS & ROOF PLAN
P 6 - ELECTRICAL PLAN
LEGAL DESCRIPTION
LOT 16 CROOKED STICK ESTATES, SECTION ONE, IN
HAMILTON COUNTY, INDIANA AS RECORDED IN PLAT
BOOK 5, PAGES 149-151 IN THE OFFICE OF THE
RECORDER OF HAMILTON COUNTY, INDIANA.
STREED ADDRESS
10757 TORREY PINES CIRCLE3, CARMEL INDIANA
46032
EXISTING
STRUCTURE
1x GUTTERBOARD
& SOFFIT TO
MATCH EXISTINGASPHALT SHINGLES TO
MATCH EXISTING
NEW ADDITION
LIMESTONE
WINDOW
TRIM
BRICK VENEER
1x GUTTERBOARD
& SOFFIT TO
MATCH EXISTING
ASPHALT SHINGLES
TO MATCH
EXISTING
NEW ADDITION
BRICK VENEER
NEW ADDITION
BRICK VENEER
STUCCO BOARD &
CEDAR TRIM TO
MATCH EXISTINGWROUGHT IRON
RAILING
BRICK VENEER
EXISTING
STRUCTURE
BRICK VENEER
ASPHALT SHINGLES TO
MATCH EXISTING
LIMESTONE
WINDOW
TRIM
1x GUTTERBOARD
& SOFFIT TO
MATCH EXISTING
NEW ADDITION
EXISTING
STRUCTURE
E U R O P E A N I N F L U E N C E L L C
5 8 0 1 F o r e s t L a n e
I n d i a n a p o l i s , I N 4 6 2 2 0
3 1 7 -4 1 8 -1 7 1 2
C o p y r i g h t 2 0 1 5
E u r o p e a n I n f l u e n c e L L C
A l l r i g h t s r e s e r v e d
s h a l l n o t b e c o p i e d o r
a p p r o p r i a t e d .
Revisions:
File:
LAYOUT - ARCH D
SHEET
2
Date:
12/17/15
Scale 1/4"=1'
Scale 1/4"=1'
L A C K
E Y R E S I D E N C E
1 0 7 5 7
T O R R E Y P
I N E S C I R C L EScale 1/4"=1'R IGHT ELEVATIONFRONT ELEVATIO N
R EAR ELEVATION
2 6 6 826682668
2 6 6 8
2168
UP
UP
7 '
3 '-5 3 /1 6 "
2 1 '
12'-4"
12'-4"
2 '
2 2 '-4 "
2 '
1 7 '-8 "
13'-10"
STEP BRICK
LEDGE
AS REQD BY
GRADE
UTILITY UNFINISHED
EXISTING
CLOSET
CRAWL
CRAWL
CRAWL
INTEGRAL CONC
LINTEL
MIN 4" PEA FILL OVER
VAPOR BARRIER
8" CONC CRAWL WALL
MIN 4' HT STEP AS
REQUIRED FOR GRADE
8X16 CONC FOOTER
WITH 2 #2 REBAR
CRAWL ONLY
60" x 32"
ACCESS
INTEGRAL CONC
LINTEL
2 X 10 FJ
16" OC
MIN 4" PEA FILL OVER
VAPOR BARRIER
8" CONC CRAWL WALL
MIN 4' HT STEP AS
REQUIRED FOR GRADE
8X16 CONC FOOTER
WITH 2 #2 REBAR
CRAWL ONLY
OVER EXISTING
CONCRETE SLAB
FOUNDATION
INTEGRAL CONC
LINTEL
CRAWL ACCESS
USE EXISTING
WINDOW OPENING
2 X 10 FJ
16" OC
EXISTING
GARAGE
FOUNDATION
EXISTING
BASEMENT
FOUNDATION
ADDED
4" STEEL
COLUMN
RECONFIGURED INTERIOR WALLS
EXISTING INTERIOR WALLS
EXISTING
BASEMENT
FOUNDATION
EXISTING
BATH
STEP4" BRICK
LEDGE STEP
AS REQD BY
GRADE
NEW FOUNDATION WALL
EXISTING FOUNDATION WALL
EXISTING DECK
FOUNDATION
EXISTING
BASEMENT
FOUNDATION
LVL
E U R O P E A N I N F L U E N C E L L C
5 8 0 1 F o r e s t L a n e
I n d i a n a p o l i s , I N 4 6 2 2 0
3 1 7 -4 1 8 -1 7 1 2
C o p y r i g h t 2 0 1 5
E u r o p e a n I n f l u e n c e L L C
A l l r i g h t s r e s e r v e d
s h a l l n o t b e c o p i e d o r
a p p r o p r i a t e d .
Revisions:
File:
LAYOUT - ARCH D
SHEET
3
Date:
12/17/15
FO U N D ATIO N P LAN
Scale 1/4"=1'
NEW CRAWL SPACE AREA -
544 SQ FT
L A C K
E Y R E S I D E N C E
1 0 7 5 7
T O R R E Y P
I N E S C I R C L E
DN
DN
2668
7674 ARCH
7 2 7 4 A R C H
7 2 7 4 A R C H
2
6
6
8
2 8 6 8 A R C H
2 6 6 8
2468
2468
4 0 6 8
3
6
7
4
A
R
C
H
3 0 6 8
2 6 6 8
2 4 6 8
146830681468
1
6
0
7
0
1
6
0
7
0
2
6
6
8
2 8 6 8
3074 ARCH
2 8 6 8
5 0 8 0
4068
5 8 6 8 A R C H
3 6 6 8 A R C H
1 1 1 6 8
2 6 6 8 C O
2668 CO 2668
UP
UP
UP
8 ' C L G H T
1 1 ' C L G H T
1 1 ' C L G H T
A1A1
B2B2
3 '-1 0 1 /2 "
5 '-5 "
8 '-8 "
8 '-8 "
13'-6"2'-9"9'-6"2'-9"
1 7 '-8 "
7 '-2 "
2 '-9 "
7'-8 5/8"
6 '-4 3 /8 "
7'-10 3/8"
6'-5 3/16"
9 '-2 "
7'-5 5/16"
8 '-1 3 /4 "
4 '-2 1 3 /1 6 "
2'-6 1/4"5'-2"
10'-10 1/8"
4
'
2
'
-
5
"
4 '-4 "
6'-3 7/16"
2'-6 1/16"
3 '-6 5 /1 6 "
2 '-5 3 /1 6 "
2 1 '-3 "
2 1 '-3 1 /2 "
13'-6"14'-4"
1 4 '
5 '-8 "
7 '-8 3 /8 "
2 3 '-1 3 /4 "
1 3 '-1 1 3 /4 "
2'6'-8"2'
7'7'-8"
5'-6"1'-11 1/2"
7'-9"12'-4"
4 '-1 0 "
4 '-6 "
6 '-7 "
12'-0 1/2"4'15'-5"
1 0 '-8 1 /2 "
1 0 '
2'-9"
2'-6 3/4"9'-2 5/8"2'-6 5/8"
3 '
1 7 '
GARAGE
GARAGE
LAUNDRY/
OFFICE
DELETE
EXISTING
STAIRS &
BALCONY TO
2ND FLOOR
MASTER BDRM
DINING
OFFICE
ADD STEP
MASTER
CLOSET
FOYER
SUN ROOM
GREAT ROOM
PANTRY
BREAKFAST
AREA
MASTER BATH
MASTER
CLOSET
KITCHEN
DECK
EXISTING
FLATTEN CLG
AT 12'
9' CLG HT
9' CLG HT
B E V
C E N T E R
11' CLG HT
S E A T
BATH
LVL
9' CLG HT
I C E
8 ' C L G H T
9 ' C L G H T
9' EXT
WALL
STEEL
BEAM
4" STEEL COLUMN
THROUGH TO
BASEMENT BEAM
8' CLG HT
4" STEEL
COLUMN
RECONFIGURED INTERIOR WALLS
EXISTING INTERIOR WALLS
8' CLG HT
E U R O P E A N I N F L U E N C E L L C
5 8 0 1 F o r e s t L a n e
I n d i a n a p o l i s , I N 4 6 2 2 0
3 1 7 -4 1 8 -1 7 1 2
C o p y r i g h t 2 0 1 5
E u r o p e a n I n f l u e n c e L L C
A l l r i g h t s r e s e r v e d
s h a l l n o t b e c o p i e d o r
a p p r o p r i a t e d .
Revisions:
File:
LAYOUT - ARCH D
SHEET
4
Date:
12/17/15
M AIN L EV EL FLO O R P LAN
Scale 1/4"=1'
L A C K
E Y R E S I D E N C E
1 0 7 5 7
T O R R E Y P
I N E S C I R C L E
DN
DN
2 5 6 8
2668
2 6 6 8
2 6 6 8
2668 2668
6 0 6 8
5768 CO
4 0 6 8
2 6 6 8
5080
1 9 6 8
2
6
6
8
2 6 6 8
5 0 6 8
2 6 6 8
UPUP
4 '-8 1 /1 6 "
7 '-4 "
6 '-0 1 /2 "
12'-5"
7'-2 9/16"7'-0 3/16"
14'-0 15/16"9'-1 5/16"
3 '-6 "
4'-4"5'-10 3/4"4'-4"
1 3 '-9 3 /4 "
4 '
STEP
2' KNEE
WALL
GABLE
WALL
BEDROOM
WROUGHT
IRON
RAILING
HALL
BEDROOM
BONUS
BEDROOM
DECK
BATH
2' KNEE
WALL
WALL OFF
EXISTING
DOOR
ATTIC
RAILING
RECONFIGURED INTERIOR WALLS
EXISTING INTERIOR WALLS
DELETE
EXISTING
HALL WALLS
1 2 : 1 2
1 2 : 1 2
1 2 : 1 2
1
2
:
1
2
12 : 12
1 2 : 1 2
1 2 : 1 2
1 2 : 1 2
12 : 12
12 : 12
1 2 : 1 2
12 : 12
12 : 12
1 2 : 1 2
12 : 12 12 : 12
1 2 : 1 2
1 2 : 1 2
12 : 12
1 2 : 1 2
12 : 12
12 : 12
12 : 12
12 : 12
12 : 12
12 : 12
STEP
2' KNEE
WALL
GABLE
WALL
2' KNEE
WALL
WALL OFF
EXISTING
DOOR
RAILING DELETE
EXISTING
HALL WALLS
EXISTING
FLAT ROOF
SECTION
NEW ROOF
SECTION
NEW ROOF
SECTION
TYPICAL EXTERIOR WALL
INSULATION VALUES
EXTERIOR FILM R 0.17
STONE VENEER R 0.39
1" AIRSPACE R 1.01
1/2" SHEATHING R 0.62
FIBERGLASS INS.R 13.00
1/2" DRYWALL R 0.45
INTERIOR FILM R 0.68
TOTAL WALL SYST R 16.32
2 '-8 "
8 '-1 1 /8 " V A R I E S
2x10 FJ 16"OC
2 #4 STEEL REBAR CONTINUOUS
4" PERIMETER DRAIN IF SUMP REQUIRED
8" X 16" CONC FOOTING
DAMP PROOFING
GRADE
WEEP HOLES 4' O.C.
MASONRY FLASHING
BRICK VENEER (MIN 1" AIR SPACE)
6" CONTINUOUS GUTTER
3/8 HARDY SOFFIT WITH
CONTINUOUS SCREEN VENT
SHINGLES & FELT PER SPEC OVER 7/16"
OSB DECK
2 X 6 MIN RAFTERS 16" O.C.
1X6 FRIEZE
1/2" OSB SHEATHING WITH
MOISTURE BARRIER TYP
8" GRAVEL BED OVER
VAPOR BARRIER, SLOPE
TO SUMP OR TIE INTO
EXISTING FOUNDATION
DRAIN
1X6 FACIA
2X10 C.J.
R 38 CEILING INSULATION
2X4 STUDS WITH R13
INSULATION TYP
8" X 32" MIN BLOCK OR
POURED CONCRETE WALLS
FF
E U R O P E A N I N F L U E N C E L L C
5 8 0 1 F o r e s t L a n e
I n d i a n a p o l i s , I N 4 6 2 2 0
3 1 7 -4 1 8 -1 7 1 2
C o p y r i g h t 2 0 1 5
E u r o p e a n I n f l u e n c e L L C
A l l r i g h t s r e s e r v e d
s h a l l n o t b e c o p i e d o r
a p p r o p r i a t e d .
Revisions:
File:
LAYOUT - ARCH D
SHEET
5
Date:
12/17/15
U P P ER LEVEL FL O O R P L AN
Scale 1/4"=1'
R OO F P LAN
Scale 1/8"=1'
L A C K
E Y R E S I D E N C E
1 0 7 5 7
T O R R E Y P
I N E S C I R C L E
TYP ICAL WALL SECTION & R VALUES
Scale 1/8"=1'
WP
R
4
GFCI
3WP
SD
EP
DC
SD
DM
A
T
AV Control
C5/TVC5 TV
T
SP SP
DESCRIPTIONSYMBOL
ELECTRICAL - DATA - AUDIO LEGEND
Ceiling Fan
Ventilation Fans: Ceiling Mounted, Wall Mounted
Ceiling Mounted Light Fixtures: Surface/Pendant,
Recessed, Heat Lamp, Low Voltage
Wall Mounted Light Fixtures: Flush Mounted,
Wall Sconce
Chandelier Light Fixture
240V Receptacle
110V Receptacles: Duplex, Weather Proof, GFCI
Switches: Single Pole, Weather Proof, 3-Way, 4-Way
Switches: Dimmer, Timer
Audio Video: Control Panel, Switch
Wall Jacks: CAT5, CAT5 + TV, TV/Cable
Telephone Jack
Intercom
Thermostat
Door Chime, Door Bell Button
Smoke Detectors: Ceiling Mounted, Wall Mounted
Electrical Breaker Panel
Speakers: Ceiling Mounted, Wall Mounted
Fluorescent Light Fixture
DN
DN
UP
UP
UP
RR
RR
GFCI
GFCI
R
R
R
R
RR
RR
RRR
R
R
RR
R
RR
R
RR
R
R
RR
R
R
R
R
R
R
R
R R R
GFCI
GFCI
GFCI
3
GFCI
3
3
GFCI
3
GFCIGFCI
GFCIGFCI
3
3
GFCI
GFCI
GFCIGFCI
3
3
3
GFCIUP TO LANDING
RECESSED LIGHTS
TIE TO EXISTING
LIGHTS
TIE TO EXISTING
LIGHTS
TIE TO EXISTING
LIGHTS
TIE TO EXISTING
LIGHTS
UP TO 2ND FLOOR
SWITCH
TO UNDERCOUNTER &
IN CABINET LIGHTINGUSE UNDER CABINET
STRIPS ON GFCI
CITCUIT FOR ALL
COUNTER OUTLETS
TO EXISTING
SWITCH
TV
OUTLET
TV
OUTLET
TV
OUTLET
UNDER
CABINET
LIGHT
DN
DN
UPUP
R
R
R
R
R
R
4
GFCI
GFCI
4
GFCI
4
TO EXISTING EXT
LIGHT
DOWN TO LANDING
RECESSED LIGHTS
E U R O P E A N I N F L U E N C E L L C
5 8 0 1 F o r e s t L a n e
I n d i a n a p o l i s , I N 4 6 2 2 0
3 1 7 -4 1 8 -1 7 1 2
C o p y r i g h t 2 0 1 5
E u r o p e a n I n f l u e n c e L L C
A l l r i g h t s r e s e r v e d
s h a l l n o t b e c o p i e d o r
a p p r o p r i a t e d .
Revisions:
File:
LAYOUT - ARCH D
SHEET
6
Date:
12/17/15
Scale 3/16"=1'
ELECTRICAL DIAGRAM - M AIN LEVEL
NOTE EXISTING ELECTRICAL
SWITCHES, OUTLETS AND
LIGHTING IN NOT SHOWN AND
WILL REMAIN UNCHANGE
UNLESS NOTED
ELECTRICAL DIAGRAM - UP PER LEVEL
Scale 3/16"=1'
L A C K
E Y R E S I D E N C E
1 0 7 5 7
T O R R E Y P
I N E S C I R C L E