Loading...
HomeMy WebLinkAbout16030062 Building PlansSheet List Table P O T B E L LY S A N D W1 C H S H O P Sheet Sheet T�t�e 11529 SPRINGMILL ROAD SUITE 100 Number AOA COVER & GENERAL INFORMATION � A0.1 LEGENDS NOTES & ABBREVIATIONS CARMEL, I N 46032 Ao.2 EGRESSPLAN A1.0 PENETRATION &TRENCHING PLAN A1.1 CONSTRUCTION PLAN SITE VICINITY MAP PROJECT CONTACTS A1.1a ENLARGEDCONSTRUCTIONP�N A1.2 REFLECTED CEILING PLAN ����� � � �{ � � ' " �"� �' � r .y r �� x-�� �r ���� POTBELLY SANDWICH WORKS, INC. GERSHMAN PARTNERS A1.3 FLOOR FINISH PLAN . . � . . . . � � . . > � m -s�`�`��""�''�� ac �`" �� Ir{A'±�!" �§r �, o : , . -�ssn :�s �c }�� �`����,;v;� - � . � � � � � � ,��,��.���;���-�, � ��_�„ , �� �;.�� � � ,. ��>x s,��� �; 111 N. CANAL, SUITE 850 600 E. 96TH STREET, SUITE 150 � t , � �����;�, � u ,L � � ��, � , � � A1.4 FURNITURE FIXTURE AND EQUIPMENT PLAN � � � � � ; ��;��"���`"�� � , � ,�� ��� _ � x "� e�,����,�� � � �`'� CHICAGO, ILLINOIS 60606 � INDIANAPOLIS, IN 46240 � � �} µ��..��� r��� ���� �� �� ���-���. � ��� �' �'� �� ,� ta`�'; PROJEGT A1.5 CASEWORK PLAN Y �`�"�_ �xk � '� �'���� `` � � �;�� ���' '�`"'�� ���: LOCATION DESIGN MNGR: JENNIFER STARR CONTACT: BUZZ WEISGIER � � � ����,3�m� ����� { 3 � � �Y�'�;��� , � �� -� A1.6 ENLARGED TOILET ROOM PLANS & DETAILS PH: (312) 334-5823 PH: 314.599.4800 . . � � � � �a �'�- `.'�.,��+.�`'.� x�ar . -j.. �.� .. �,r.;,� �`%� a � .. s�. . . . „�"�'x� ���� � �. �m� � ,�� -_ � `#� ' � EMAIL JENNIFER.STARR@POTBELLY.COM EMAIL:CWCBUZZ@GERSHMANPARTNERS.COM A2.0 DOOR SCHEDULES & DETAILS _ " . fiJ�" -•��E'� � i°� 7 "' ¢ �'.t,�¢�,� t4�°?=�'�.�:x2,�, � � � � �°i z . � �.7t=� r" � . r�n.`` ��� i -�,. � - -�,,��+;�, � 't . � ry;, ��� �, ,,���� x ,� r� „� �� ��� CONSTRUGTION MNGR: PAULAOLDHAM A2.1 FINISH SCHEDULE �'�F`�'ri � � xk� ���'�' �� � > � �i °�, � PH: 774-270-6995 A2.2 FINISH SCHEDULE (CONT.) � � . . �'f �� � � if s �� {"yh�° ��� �`�`�, � x � ��- ' , ������ ��� � EMAIL: POLDHAM@PLUMPROJECTSERVICES.COM A2.3 FURNITURE FIXTURE & EQUIPMENT SCHEDULES o, . � � . . � � ��*�„�'�.�r��� t s � r '�"�`�� �3 � , . -�,r.'�" 9 � �. � � � � ��' � �.� . . � ��r � � �� � ��"���"���„, ,n�i.`�� ��r' � ' �~�` �� A2.4 FURNITURE FIXTURE & EQUIPMENT SCHEDULES (CONT.) �' � � ���t , f*��� ��� ��� � ' ""���k�� � �'" t� ���' m ARCHITECT: MEP ENGINEER: �� h-�� „� �, c�.�� . h `� ���"�,, r��� `�' � ' A2.5 PLUMBWG SCHEDULE ��� � ����.� , ,, �c � a ��� � GPD GROUP GPD GROUP � '`�"' � " � # �,�h���t�, r '�"� �� ,�"��� �;, A2.6 LIGHTWGSCHEDULE � � �*� �,� �,�,�,, ��,�.�, ��� �, y # r � vF : 1! 520 S. MAIN STREET, SUITE 2531 520 S. MAW STREET, SUITE 2531 � � � �` � � � ��'�'� �°�c�� �������-�„-"�`���� .5 A27 CASEWORKSCHEDULE �:�'TM,.� � � � s �a�j��� �,�� � � � m �� � .�}� AKRON, OH 44311 AKRON, OH 44311 . . . . . �' *� t� iC � i�'�''�k' '4a' �t�'''P^ f � .:4 .S � , �.",:GC,u' . �� � t=,�� �� t Y' '��' CONTACT: LEANNE ANDRYSCO CONTACT: LEANNE ANDRYSCO A2.8 CASEWORK SCHEDULE (CONT.) �� � `� � ;� �;�� ' f,: � �{;� i„� � �`���,�,� ,������ �� � �' { NORrH PH: (216) 927-8641 PH: (216) 927-8641 A2.9 CASEWORK SCHEDULE (CONT.) . . :� �` r���I. �"��` �., r ��"` 'i � ����.., �.� . �, ,�,,,. y '� �� �'��" �g�'�� � ���� EMAIL: LANDRYSCO GPDGROUP.COM EMAIL: LANDRYSCO GPDGROUP.COM � ,���?��N���� ��'� �k � : �� �� � `� s�r @ @ A3.0 EXTERIOR ELEVATIONS � �.'��:; . .._ , ,�� � ti.�'�..-� �3�>.�=. E� � _ � ' � � �.... ����,��„ � �� ��'� � A4.0 INTERIOR ELEVATIONS � ��.. ��. SITE KEY PLAN APPLICABLE CODES A4.� INTERIORELEVATIONS A4.2 INTERIOR ELEVATIONS BUILDING CODE: 2014 INDIANA BUILDING CODE A4.3 INTERIOR ELEVATIONS PLUMBWG CODE: 2012 INDIANA PLUMBING GODE A4.4 INTERIOR ELEVATIONS MECHANICAL CODE: 2014 INDIANA MECHANICAL CODE A5.0 INTERIOR DETAILS ELECTRICAL CODE: 2014 INDIANA ELECTRICAL CODE AREA ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) A5.1 INTERIOR DETAILS O OF WORK FIRE CODE: 2014 INDIANA FIRE CODE A5.2 INTERIOR DETAILS � ACCESSIBILITY CODE: ANSI 117.1-2009 Oe A5.3 fNTERIOR DETAILS A5.4 INTERIOR DETAILS SITE INFORMATION�OCCUPANCY AS1.0 ARCHITECTURALSPECIFICATIONS r----� II AS1.1 ARCHITECTURAL SPECIFICATIONS I� �I II I I I I II AS1.2 ARCHITECTURAL SPECIFICATIONS I I I I II PROJECT DESCRIPTION: COMMERCIAL TENANT fMPROVEMENTS TO EXISTING AS1.3 ARCHITECTURAL SPECIFICATIONS I _ I II BUILDING �----- - � ZONING: PUD - PLANNED UNIT DEVELOPMENT AS1.4 ARCHITECTURAL SPECIFICATIONS I I CONSTRUCTION TYPE: VB - SPRINKLED M1,0 MECHANICAL LEGEND AND NOTES L___ J OCCUPANCY CLASSIFICATION: A-2 M2.0 MECHANICAL PLAN USE GROUP: RESTAURANT AREA OF CONSTRUCTION: 2,240 SQ.FT. M3.0 MECHANICAL SCHEDULES NORTH M4A MECHANICAL DETAILS # OF STORIES: 1 rG� I� BUILDING HEIGHT: 34'-5" APPROX. M5.0 MEGHANICAL ROOF PLAN � P1.0 PLUMBWG LEGEND AND NOTES P2.0 PLUMBWG SUPPLY AND SCHEDULES ROOM AREA SF OCCUPANCY TOTAL OCCUPANT LOAD gg P3A PLUMBING WASTE PLAN DINING 450 SQ. FT. 450/15=30 (DOES NOT WCLUDE P4A PLUMBWG SCHEDULE SEATS 51 51 SEATS OUTDOOR SEATWG) QUEUING 220 SQ. FT. 22015=44 P5.0 PLUMBING RISERS SERVICEIPREP 715 SQ. FT. 715/200=4 TOTAL # OF SEATS: 77 P6.0 PLUMBWG DETAILS INDOOR: 51 E1.0 ELECTRICAL LEGEND AND NOTES OUTDOOR: 26 E2.0 POWER PLAN E3.0 LIGHTING PLAN # FIXTURES REQUIRED: (125/2 = 63 MENS, 63 WOMENS) E4.0 SYSTEMS PLAN MEN: 1 WC, 1 LAV E5.0 LIGHTING SCHEDULE WOMEN: 1 WC, 1 LAV SERVICE SINK: DRINKWG 1 E6.0 PANEL SCHEDULES FOUNTAIN: 1 E7.0 ELECTRICAL DETAILS # OF FIXTURES PROVIDED: MEN: 1 WC, 1 LAV WONiEN: 1 WC, 1 LAV SERVICE SINK: 1 DRWKING FOUNTAIN: WATER SERVICE IS PROVIDED DIRECTLY TO CUSTOMER REQUIRED EGRESS WIDTH: 44" COMMON PATH OF EGRESS: 75' MAXIMUM EXIT TRAVEL DISTANCE: 250' (W/SPRWKLER SYSTEM) ; # EXITS REQUIRED: 2 g # EXITS PROVIDED: 2 awr�v�r��n a 1' ,� 222 MERCHANDISE MART PLA7A, SUITE 2300 CHICAGQ IL. 60654 P: 312 951.0600 P: 312.951.0300 WNNV.POTBELLY.COM � � /'/� GPD GROUP, INC. � 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Faz:330.572.2102 WC G Q U � � Z M � z LLI � U � � � 0 � 0 N � w m � _ z U w 0 � a m0����� � ° 43^ �����4 i i�.t � � f° qgo m r�,.� �'.. `. .�jSC��Yti . . 6aJ-n _ `�;.;;, '�:� ��'° � ,� „ � �.... "vC" ro'y �t' u �> ., � SHEET TITLE COVER AND GENERAL INFORMATION SHEET NUMBER A0.0 a Z J � 0 AC ACC ACT ADJ AFF ALUM AMP APPRO ARCH BD BLDG BLKG BOB BOH CAB CD CKT CLG CLR CM GMNT CMU CNTRS CO COORD CTR CL COL COMP CONC CONT CONST COORD CT CW DEG DIA DIM DN DTL DW DWG(S) EA EC ELEC ELEV EQ EQUIP EXIST EXP EXT FCO FFE FIN FIO FIXT FLEX FOC FOG FOH FOIC �. FP FLR FRA FT FV GA GALV GC GRND GWB HC HD HDR HDWD HDWR HM HORZ HR HT HVAC HW ID IF IG INSUL AIR CONDITIONING ACCESSIBLE ACOUSTICAL CEILING TILE ADJUSTABLE ABOVE FINISHED FLOOR ALUMINUM AMPERAGE X APPROXIMATE ARCHITECTURAL BOARD BUILDING BLOCKWG BOTTOM OF BEAM BACK OF HOUSE CABINET CONDENSATE DRAIN CIRCUIT CEILING CLEARICLEARANCE CONSTRUCTION MANAGER CEMENT CONCRETE MASONRY UNIT CENTERS COMPANY COORDINATE CENTER CENTERLINE COLUMN COMPARTMENT CONCRETE CONTINUOUS CONSTRUCTION COORDINATE CERAMIC TILE COLD WATER DEGREES DIAMETER DIMENSION DOWN DETAIL DISHWASHER DRAWWGS EACH ELECTRICAL CONTRACTOR ELECTRICAL ELEVATION EQUAL EQUIPMENT EXISTING EXPOSED EXTERIOR FLOOR CLEANOUT FURNITURE, FURNISHINGS AND EQUIPMENT FINISHED FURNISHED & INSTALLED BY OWNER FIXTURE FLEXIBLE FACE OF CABINET FACE OF GLAZING FRONT OF HOUSE FURNISHED BY OWNER & INSTALLED BY CONTRACTOR FACE OF STUD FIBERGLASS REINFORCED PANEL FIRE PROTECTION FLOOR FR,4ME FOOT/FEET FIELD VERIFY GAUGE GALVANIZED GENERALCONTRACTOR GROUND GYPSUM WALL BOARD HOLLOW CORE HEAD HEADER HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATIN� VENTILATIN� AIR CONDITIONING HOT WATER WSIDE DIAMETER INSIDEIINTERIOR FACE INDEPENDENT GROUND INSULATION IATIONS INFO INFORMATION IW INDIRECT WASTE KEC KITCHEN EQUIPMENT 1L MAX MC MDF MECH MEP MFG MIN NAT NIC NL NSF NTS OA OC OD OF OFI OPNG OPP PC PERP PLAM PLEX PLYW PM POC POS PSW PSW-H GONSULTANT LANDLORD MAXIMUM MECHANICAL CONTR,4CTOR MEDIUM DENSITY FIBERBOARD MECHANICAL MECHANICAL, ELEGTRICAL AND PLUMBING MANUFACTURER MINIMUM NATURAL NOT IN CONTR,4CT NIGHT LIGHT NATIONALSANITATION FOUNDATION NOT TO SCALE OVER ALL ON CENTER OUTSIDE DIAMETER OUTSIDE FACE OWNER FURNISHED ITEM OPENWG OPPOSITE PLUMBING CONTACTOR PERPENDICULAR PLASTIC LAMINATE PLEXIGLAS D PLYWOOD PROJECT MANAGER POINT OF CONNECTION POINT OF SALE POTBELLY SANDWICH WORKS UB POTBELLY SANDWICH WORKS - HUBBARD WAREHOUSE PSW-CS POTBELLY SANDWICH WORKS - PT RT RECEP REF REFRI REQ('D REV RND RO SC SF SHT SHT M SIM SOL SPEC SQ ST SS STG STRUC STL SUSP SW T&G TEL TEMP TYP UC UNO V VAL VCT VD VERT VIF WD WH XFMR CONSTRUCTION SERVICES PAINT QUARRY TILE RADIUS T RECEPTACLE REFERENCE G REFRIGERATOR ) REQUIRED REVISED/REVISION ROUND REVERSE OSMOSIS SOLID CORE . SQUARE FEET SHEET TL SHEET METAL SIMILAR SOLID SPECIFICATION(S) SQUARE STAW STAINLESS STEEL STORAGE T STRUCTURAL STEEL SUSPENDED SOFTENED WATER TONGUE & GROOVE TELEPHONE TEMPORARY TYPICAL UNDERCOUNTER UNLESS NOTED OTHERWISE VENT VALIDATION VINYL COMPOSITION TILE VENDOR VERTICAL VERIFY IN FIELD WOOD WATER HEATER TRANSFORMER 101 A0.1 � NORTH � rh HEIGHT D TA UM � � C SYMBOLS LEGEND ELEVATION TAG TOP = ELEVATION NUMBER BOTTOM = SHEET NUMBER DETAIL TAG TOP = ELEVATION NUMBER BOTTOM = SHEET NUMBER SECTION TAG TOP = ELEVATION NUMBER BOTTOM=SHEETNUMBER REVISION CLOUD ! TAG NUMBER DENOTES NUMBER OF ADDENDUMS TRUE NORTH SHOWS DIRECTION OF MAGNETIC NORTH PLAN NORTH AS REFERENCED TO IN ALL DRAWINGS CONTAINED IN THIS SET ELEVATION BENCHMARK NUMBER DENOTES REFERENCE TO KEY NOTES ON SPECIFIED SHEET DOOR TAG NUMBER DENOTES DOOR REFERENCE TO DOOR SCHEDULE WINDOW TAG LETTER DENdTES WINDOW REFERENCE FURNITURE/ACCESSORY/CASEWORK/EQUIPMENT/ � SIGNAGE TAG NUMBER DENOTES REFERENCE TO FURNITURE & ACCESSORIES SCHEDULE FINISH TAG L-3 NUMBER DENOTES INTERIOR FWISH MATERIAL, REFER TO FINISH SCHEDULE X'-X" AFF �^J � � O AFF HEIGHT TAGS HEIGHT ABOVE FINISHED FLOOR WALL TYPE TAG LETTER DENOTES WALL TYPE WALL BLOCKING TAG LETTER DENOTES WALL BLOCKING LOCATION WALL MOUNTED SPEAKER CEILING RECESSED SPEAKERS GRAPHIC SCALE DENOTES SCALE OF DRAWING GENERAL NOTES 1. GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VISIT THE SITE AND VERIFY ALL SITE CONDITIONS PERTAINING TO THIS PROJECT PRIOR TO SUBMISSION OF BIDS. ANY DISCREPANCIES FOUND DURING SITE INVESTIGATION TO BE REPORTED TO OWNER'S REP IN WRITING PRIOR TO BID SUBMISSION. G.C. TO ENSURE THAT EXISTING STRUCTURE IS NOT ALTERED OR DAMAGED WITH EXCEPTION OF MODIFICATIONS SHOWN ON DRAWINGS. ALL INSTALLATIONS AND ALL CONNECTIONS TO EXISTING BUILDING MECHANICAL SYSTEMS SHALL BE COORDINATED WITH AND PERFORMED UNDER THE SUPERVISION OF THE LANDLORD'S REPRESENTATIVE. 2: ALL EXISTWG CONDITIONS, STRUCTURAL AND MECHANICAL CONNECTIONS TO ALL EXISTING BUILDING SERVICES MUST BE FIELD VERIFIED PRIOR TO SUBMISSION OF BIDS. ANY DISCREPANCIES SHALL BE REFLECTED AND NO ADJUSTMENT TO BID PRICE SHALL BE MADE AFTER BID SUBMISSION. SUBMISSION OF BID SHALL BE UNDERSTOOD AND CONSTRUED AS CONTRACTOR HAVWG VERIFIED ALL EXISTING CONDITION. WHETHER OR NOT SHOWN ON DRAWINGS AND HAVING TAKEN WTO ACCOUNT ANY ADJUSTMENT NECESSARY TO FULFILL THE DESIGN INTENT IN FULL AND COMPLETELY. 3. REFER TO FURNISHINGS, FIXTURE & EQUIPMENT SHEET FOR ALL EQUIPMENT LOCATIONS. REFER TO EQUIPMENT MANUAL & ENGINEERING DW�S. FOR EQUIPMENT REQUIREMENTS. NOTIFY OWNER'S REP OF ANY DISCREPANCIES. 4. G.C. TO COMPLY WITH LANDLORD'S AND OWNER'S RULES AND REGULATIONS REGARDING CONSTRUCTION WITHIN THE BUILDING. GC & ALL SUBCONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH THE BASE BUILDING AND TO VERIFY WITH THE LANDLORD BEFORE MODIFYING OR ATTACHING NEW CONSTRUCTION TO BASE BUILDING. GC SHALL PATCN AND REPAIR ALL EXISTWG WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE WORK. 5. G.C. TO CQORDINATE LAYOUT, ROUTING, AND INSTALLATION OF ALL NEW MECHANICAL, ELECTRICAL, FIRE PROTECTION, AND PLUMBING WORK WITH EXISTIN� MEP/FP SYSTEMS, AND WITH EXISTING STRUCTURE TO REMAIN. REPORT ALL DISCREPANCIES TO OWNER'S REP IN WRITING PRIOR TO SUBMITTING BID PACKA�E. 6. EACH CONTRACTOR OR SUBCONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, AND LICENSES REQUIRED FOR PROPER EXECUTION OF THEIR PORTION OF THE WORK. THIS EXCLUDES MAIN BUILDING PERMITS, BUSINESS & HEALTH LICENSES. 7. EACH CONTRACTOR OR SUBCONTRACTOR SHALL COMPLY WITH ALL PROVISIONS OF ALL APPLICABLE LAWS AND ORDER OF PUBLIC OFFICIALS WITH JURISDICTION FOR SAFEfY OF PERSONS/PROPERTY. 8. ALL WORK SHALL BE DONE BY LICENSED CONTRACTORS AND IN CONFORMANCE WITH ALL NATIONAL, STATE, COUNTY, AND LOCAL CODES. ANY VARIANCE/NON-COMPLIANCE WITH LOCAL CODE TO BE REPORTED TO OWNER'S REP IN WRITING PRIOR Td BIDS. 9. G.C. & ALL SUBS TO FAMILIARIZE THEMSELVES WITH THE BASE BUILDING AND TO VERIFY WITH LANDLORD BEFORE MODIFYING OR ATTACHING NEW CONSTRUCTION TO BASE BUILDING. 10. G.0 SHALL VERIFY ALL EQUIPMENT, MILLWORK, AND OTHER ITEMS BEING FURNISHED BY OWNER OR OWNER'S CONTRACTORS FOR WHICH G.0 IS RESPONSIBLE FOR INSTALLING ARE IN GOOD CONDITION. 11. �.C. ASSUMES COMPLETE RESPONSIBILITY WHEN OWNER FURNISHED ITEMS ARE ACCEPTED AND RECEIVED BY G.C. 12. G.C. TO ENSURE THAT A COMPLETE SET OF CONSTRUCTION DOCUMENTS IS GIVEN TO ALL SUBCONTRACTORS PRIOR TO BID SUBMISSION. 13. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENT. IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY OWNER'S REP IMMEDIATELY. ALL DIMENSIONS ARE FROM FACE OF FINISH SURFACE TO FACE OF FINISH SURFACE UNLESS OTHERWISE NOTED. 14. ALL WOOD W CONTACT WITH CONCRETE AND AT EXTERIOR LOCATIONS MUST BE PRESSURE TREATED MOISTURE RESISTANT WOOD. 15. ALL WALL GONSTRUCTION FACING PLUMBING FIXTURE AREAS MUST UTILIZE MOISTURE RESISTANT GYPSUM BOARD UNLESS OTHERWISE NOTED. 16. G.C. TO FILL AND STAIN ALL NAIL HOLES. 17. G.C. TO CAULK ALL BASE AND CHAIR RAIL TO DISSIMILAR MATERIALS. 18. G.C. TO PROVIDE AS BUILT DRAWINGS (CONSISTING OF REDLINED CONSTRUCTION DRAWINGS} TO OWNER'S REP WITHIN TWO WEEKS OF COMPLETION OF PROJECT, PRIOR TO FINAL PAYMENT. 19. G.C. TO COVER WINDOWS AS REQUIRED, DURING CONSTRUCTION WITH CRAFT PAPER T010 FT. CONFIRM WITH CENTER RULES & REGULATIONS. 20. KEEP DRIVEWAYS AND ENTRANCES CLEAR AT ALL TIMES. EACH SUBCONTRACTOR SHALL REMOVE RUBBISH AT THE COMPLETION OF HIS WORK. PROMPTLY REPAIR ANY DAMAGE DONE TO ADJACENT PROPERTYITENANT SPACES AT NOT COST TO OWNER. 21. TWO (2) FIRE EXTINGUISHERS TO BE SUPPLIED BY OWNER, LOCATED BY FIRE MARSHAL, INSTALLED BY G.C. FIRE EXTINGUISHERS: LARSON #MP5 WITH UL RATWG OF 2A-10B:C 22 INSTALLATION & FINISHWG OF WOOD FLOORING, CONCRETE STAIN AND KITCHEN PAINT TO BE BID AS NIGHT WORK. 23. ALL LIGHT SWITCHES, THERMOSTATS, SECURITY ALARMS, ELECTRICAL OUTLETS, ETC. MUST BE MOUNTED TO MEET ALL GOVERNWG ACCESSIBILITY REQUIREMENTS FOR FLOOR & HEIGHT CLEARANCES AND ONE HAND GRASPING OPERATION. 24. FLAME SPREAD RATINGS FOR INSULATION AND FINISHES: A. ALL CONCEALED BATT & BLANKET INSULATION TO BE USED IN THE WALL AND ATfIC IS TO BE CLASS A OR BETTER, FLAME SPREAD 25 OR LESS & A SMOKE-DEVELOPED RATING OF 450 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. B. ALL WALL & CEILtNG FINISHES TO BE CLASS B OR BETTER, FLAME SPREAD 26-75 WITH MAXIMUM SMOKE DEVELOPED QF 450 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. C. ALL INTERIOR TRIM TO BE CLASS 2, FLAME SPREAD 76-200 WITH MAXIMUM SMOKE DEVELOPED OF 450. ALL DECORATIVE MATERIALS SHALL BE NONCOMBUSTIBLE OR MAINTAIN FLAME RESISTANCE IN ACCORDANCE WITH SECTION 8�72 D. FLOOR COVERINGS TO HAVE A FLAME SPREAD RATING NOT TO EXCEED 75. 25. ALL COMBUSTIBLE INTERIOR FINISH & TRIM ITEMS ARE TO BE APPLIED DIRECTLY TO A NON-COMBUSTIBLE BASE. 26. PROVIDE AND INSTALL OCCUPANCY SIGN IN A CONSPICUOUS LOCATION IN ACCORDANCE WITH STATE & LOCAL CODES: 27. IF THE LANDLORD OR BUILDING REPRESENTATIVE REQUIRES X-RAYING OF FLOOR, ALL COSTS SHALL BE WCLUDED IN THE GENERAL CONTRACTOR'S ORIGINAL BID. 28. G.0 SHALL VERIFYTHE LOCATION OF ALL UTILITIES. 1 �� 3. L� 5. � 7 � DECOR INSTALL NOTES GC TO INSTALL ALL OWNER PROVIDED DECOR ITEMS AS SHOWN IN DECOR PACKAGE TO BE FORTHCOMING, WCLUDING ALL MENU BOARDS AND MARKETWG SIGNAGE POTBELLY WILL PROVIDE WITH DECOR PACKAGE: A: PLYWOOD MENU BACKERS B. '/<" BLACK PIPE CUT TO THE APPROPRIATE DIMENSION ACCORDWG TO MENU SIZE. C. BOX OF HARDWARE WITH QUANTITIES SPECIFIC TO MENU SIZE WCLUDING: • 1" X %d' CARRIAGE BOLTS • %d' WING NUTS • 5" J-HOOKS • 5/8" #12 WOOD SCREWS D. BLACK METAL BRACKETS WITH SET SCREWS TO HOLD PIPE E. SOUP/SHAKE MENU BOARDS F. DESSERT MENU BOARD G. ALL FRAMED DECOR ITEMS AND KNICK KNACKS GC WILL NEED TO SUPPLY: A. 2 2' 16 GAUGE FINISH NAILS FOR ALL PICTURE FRAME DEGOR PIECES B. PLASTIC ANCHORS TO BE USED AT BRICK AND 2-4 SCREWS PER FRAME DEPENDING UPON SIZE, USE MORE IF LARGER THAN 24" X 36". C. CLEAR LIQUID NAI�S D. MISCELLANEOUS FASTENERS AND HANGING HARDWARE INCLUDING BUT NOT LIMITED T0: • 3/16" X 2%" TOG�LE BOLTS (WALL BRACKETS FOR MENU BOARDS) • 2" SELF-TAPPING SCREWS FOR METAL STUDS (WALL BR4CKETS FOR MENU BOARDS) •'/<" MACHINE THREAD CEILING HOOKS WITH TOGGLES , WASHERS AND "S" HOOKS (IF HANGWG APPLICATION FOR MENU BOARDS) • WELDED-LINK CHAIN, CUT TO SIZE ON SITE (IF HANGING APPLICATION FOR MENU BOARDS) •#10 X 2" SCREWS WITH PLASTIC WALL ANGHORS (SOUP/SHAKE MENU) GENERAL DECOR INSTALLATION INSTRUCTIONS: A. ALL PICTURE FRAMES ARE NAILED TO THE WALL WITH NAIL GUN. USE MINIMUM OF 4 NAILS PER PIECE. B. PLATES TO BE SET ON LEDGES, GLUED ON TOP AND BOTTOM WITH CLEAR LIQUID NAILS. C. ALL KNICK KNACKS TO BE GLUED DOWN WITH CLEAR LIQUID NAILS. D. HAND WASHING SIGNS TO BE AFIXED TO WALL NEAR PAPER TOWEL DISPENSERS WITH DOUBLE STICK TAPE (PROVIDED ON BACK OF SIGN). E. DO NOT USE LIQUID NAILS TO ATTACH ARTWORK TO WALLS UNLESS UNABLE TO NAIL DIRECTLY. MAIN MENU BOARD INSTALLATION INSTRUCTIONS: A. ATTACH TWO OF THE SUPPLIED "J" HOOKS TO THE TOP OF EACH PLYWOOD BACKER PANEL USING THE 5/8" X#12 SCREWS. PILOT HOLES FOR THE HOOKS ARE DRILLED 2'/" IN FROM EACH EDGE. B. HOOKS WILL HAVE 1/8" - 3/16" OF PLAY, UP AND DOWN ON THE SCREWS SO BE SURE TO CENTER THE BRACKETS OVER THE PILOT HOLES. THIS WILL ALSO ALLOW FOR ADJUSTMENT LATER IF THE MENU PANELS ARE NOT HANGING SQUARE TO THE PIPE WHEN FINISHED. C. TAKE 1 CARRIAGE BOLT AND 1 WING NUT FROM THE BAG AND BOLT THE BAG WITH THE REST OF THE HARDWARE TO ONE OF THE PLYWOOD PANELS FOR THE OPERATIONS TEAM TO USE LATER FOR ATTACHING THE MENU PANELS. D. IF THE MENU REQUIRES A STANDARD WALL MOUNT WITH BRACKETS: MOUNT THE BRACKETS WITH SCREWS AND/OR ANCHORS IN THE SPECIFIED LOCATION, MAKING SURE TO LEAVE AT LEAST 3" FROM THE CEILING OR ANY OBSTRUCTION ABOVE. E. NUMBER OF BRACKETS REQUIRED PER MENU: • LARGE (79° PIPE) - 3, EQUALLY SPACED • MEDIUM(61"PIPE)-2 • SMALL (52" PIPE) - 2 • WIDE (91 %" PIPE) - 3, EQUALLY SPACED F. IF THE MENU WILL BE HANGING FROM THE CEILING: THE PIPE WILL BE SUPPLIED WITH TWO EYE BOLTS ATTACHED. USE THE PROPER HARDWARE FOR ANCHORING INTO THE CEILWG OR STRUCTURAL JOIST. ATTACH °S" HOOKS AND APPROPRIATE LENGTHS OF CHAIN FROM THE CEILING OR STRUCTURAL JOIST TO THE EYE BOLTS IN THE PIPE. G. WHEN THE PIPE IS SECURE, HANG THE ASSEMBLED MENU PANELS IN THE ORDER INDICATED IN INSTALL GUIDE IN CONSTRUCTION BINDER. SOUP/SHAKE MENU BOARD INSTALLATION INSTRUCTIONS: A. INSTALL PLASTIC WALL ANCHORS AND #10 SCREWS IN THE DRYWALL, CENTERED AND SPACED TO MATCH THE DISTANCE BETWEEN THE D-RWG HANGERS IN THE BACK OF THE MENUS. LEAVE THE SCREW HEADS FAR ENOUGH AWAY FROM THE WALL TO CATCH THE D-RING HANGERS AND MAKE SURE THE MENU IS HANGING FLAT AGAINST THE WALL. DESSERT MENU INSTALLATION INSTRUCTIONS: A. CENTER MENU FRAME OVER ICE CREAM CABINET 1N BOTH WIDTH AND HEIGHT OR AS PER PSW REP DIRECTION. B. NAIL TO WALL WITH NAIL GUN USING MINIMUM 8 NAILS: C. PLACE CHALKBOARD PANEL ON HOOKS IN CENTER OF MENU FRAME. D. TOUCH UP NAIL HOLESBLEMISHES AS NEEDED ON MENU FRAME WITH TOUCH UP PAINT. A-FRAME TOPPER INSTALLATION INSTRUCTIONS: A. REMOVE BOTH EXISTING BLACK FRAMES THAT HOLD THE CHALKBOARDS AND PRINTED PANELS. UNSCREW THE HANGER BOLT IN THE TOPS OF THE FRAMES AND DISCARD ALONG WITH THE WASHERS AND WING NUTS (THESE CANNOT BE USED WITH THE TOP FRAME). B. PRE-DRILL 5 PILOT HOLES IN THE TOP OF ONE SIDE OF THE A-FRAME STRUCTURE. (THE TOP FRAME ONLY FASTENS TO ONE SIDE SO IT CAN STILL OPEN AND CLOSE) C. PLACE THE TOP FRAME ON TOP OF THE FULLY OPENED A-FRAME AND ADJUST SO THAT IT SITS LEVEL D. SCREW UP THROUGH THE A-FRAME INTO THE BOTTOM OF THE TOP FRAME WITH THE 5 PROVIDED SCREWS (SEE SKETCH). � �RN';UWlGH 3tlt?R'r�a 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P: 312.951.0600 F:312.951.0300 VNMN.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 � Akron, OH 44311 � 33�.57L2100 Fax:330.572.2102 O r � � � Q � J N J M � O J (� � W z � � z U t� W � N � � � LL') Q z � U � ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 c. � � �ir> s� ' �. M � � 0 � 0 N � w m � � z U w 0 � a SHEET TITLE LEGENDS NOTES & ABBREVIATIONS SHEET NUMBER A0.1 1 � I� � a � c m Wn6�CAI�Q T( R( HALLWA E� E� WALK-IN COOLER/ FREEZER nn�ni�e r.�n��i�ar� ..� �r�����.� 01 EGRESS P , ,." �".�,.,� ROOM LINE t �N EXIT TO EXTERIOR ENTRY VEST. _� i i i i _J � � NORTH �� SCALE: 1 /4"=1'-0" OCCUPANCY CALCULATION �KITCHEN - SERVICElPREP= 715 SQ. FT. / 200 SF PER OCC = 4 OCCUPANTS �ASSEMBLY - RESTAURANTS = 450 SQ. FT. !15 SF PER OCC = 3� (51 INTERIOR DINING SEATS & 26 EXTERIOR SEATS) TOTAL = 99 OCCUPANTS (95 - DINWG ROOM, 4 KITCHEN) KEY NOTES OADA TABLE LOCATION EXITING CALCULATION MAXIMUM TRAVEL DISTANCE ALLOWED (SPRINKLED) - 250' MAXIMUM TRAVEL DISTANCE PROVIDED DINING - 60'-1" KITCHEN - 50'-9" GENERAL NOTES A. ---- DASHED LINE INDICATES CLEAR PATH OF EGRESS NOTE: Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and sha11 be maintained by the owner ar authorized agent. � r� � � A�.1'1::.1/ 1wt t t t1 J sl.��l F' T�a 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 NM�W.POTBELLY.COM � � /��� GPD GROUP, INC. 520 South Main Street, Suite 2531 � Akron, OH 44311 330.572.2100 Faz:330.572.2102 O O � W H � tn 0 Q � � � N � M � O J (!� � W z Z � � � U t/� w , a� � N � � � Q Z � U � M � � 0 � 0 N � W m � � Z U w O � a qo��0; � ��' �"aaa �m.� �' " � � ,<�''m, �� ' �' � ` ;, ,,-'.<� r . ' `� � .,,:a �.; ; �' � �. ; � �� t. ., .. � �trv � � ��� / � SHEET TITLE EGRESS PLAN SHEET NUMBER �� TRENCHING & PENETRATION PLAN O NORTH � SCALE: 1/4" = 1' OTES OFLOOR DRAIN. REFER TO PLUMBWG DRAWWGS FOR MORE INFORMATION. zO FLOOR SINK. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION. ONOT USED. Oa STUB-UP PENETRATION TO BE LOCATED ON CENTERLINE OF WALL ORAS REQUIRED PER CONDITIONS. OFLOOR PENETRATION FOR TOILET. REFER TO MANUFACTURER'S CUTSHEET FOR STUB-UP LOCATION RELATIVE TO FINISHED WALL. OWASTE LINE PENETRATIONS. SEE PLUMBING SHEETS FOR INDIVIDUAL LINE SPECIFICATIONS. ONOT USED. sO FLOOR CLEANOUT. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION. GENERAL NOTES A. TRENCH AT HATCHED AREAS OF PLAN ONLY. � �wrt;uwe4n snur�� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P:312.951.0600 f:312.951.0300 4WVW,POTBELLY.COM � � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 � Akron, OH 443ll � 330.572.2100 Fax: 330.572.2102 O O � W H � C� � Q � � J N J M � O � � J (!� � o W Z � � � z m v C� w � � � � � � N � w z � a � � U a 0e''��� �D �" ��°'3 00'`�.£... £ ''�, <.,��8 b �� �� t rsl P � �"i j� 4 { � L� � . ..:."� �- : ,��t `� j� t�P <e _,�, � ,�gy� ie e: '`s i %;, �.?;- � V. r �, SHEET TITLE PENETRATION & TRENCHING PLAN SHEET NUMBER A1.0 � � z s 0 z n � � � 0 N 0 � WALL TYPE LEGEND � EXISTING CONSTRUCTION TO REMAIN, PATCH & REPAIR TO LIKE NEW CONDITION � � 3A � 4A WOMEN'S TOILET ROOM �- HALLWAY WALK-IN COOLEW FREEZER FULL HEIGHT PARTITION WALL: "'m -- 20 GA 3$" MTL STUDS 16" OC WITH 8" TYPE "X" GWB ON BOTH SIDES TO DECK OR 6" ABOVE CLG. IF APPLICABLE. � DRYWALL SCREWS AT 12" OC. 45 DEGREE MTL STUD REINFORMCEMENT AT 48" OC ABOVE CLG LINE TO STRUCTURE ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFWG IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. PLUMBING WALL TO 6" ABOVE CLG: � 20 GA 3 5/8" MTL STUDS @ 3& 6" MTL STUDS @ 3A WITH $' GREEN BOARD ON ONE OR BOTH SIDES TO 6" ABOVE CLG. DRYWALL SCREWS AT 10" OC. 45 DEGREE MTL STUD REINFORCEMENT AT 48" OC ABOVE CLG LWE TO � STRUCTURE ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. EXISTING WALL 01 CONSTRUCTION P O � 0 -- PARTIAL HEIGHT WALL : 5A a 20 GA 3 8' MTL STUDS 16" OC AND 2"X2"' STEEL PIPES WITH 1/2" PLYWOOD ON BOTH SIDES TO SPECIFIED HEIGHT BELOW. REFER TO WALL SECTIONS ON A5.4 FOR MORE INFORMATION ON CONSTRUCTION. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFWG IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. 5B sc 5D � 5A 1'-11" AFF 5B Z'-10" AFF 5C 4'�1" AFF 5D 4'-0" AFF s� �— �� NOT USED. � FURRED WALL TO 6" ABOVE CLG: sA � 20 GA 2 2" MTL STUDS 16" OC WITH $" TYPE °X" GWB ON ONE SIDE T013'-0" AFF. DRYWALL SCREWSAT 12" OC. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFWG IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. FURRED PLUMBING WALL TO 6" ABOVE CLG: ❑ 20 GA 3 5/8" MTL STUDS @ 4& 6" MTL STUDS @ 4A 16" OC WITH 8' GREEN BOARD ON ONE SIDE TO 6" ABOVE CLG. � DRYWALL SCREWS AT 10° OC. APPLY CEMENT BOARD AT EASE WHERE WATERPROOFWG IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE WFORMATION. � neenue r�i �c� nnir LINE � COOLER / FREEZER WALL: BY MANUFACTURER PARTIAL HEIGHT WALL (QUEUWG LINE WALL): "m 20 GA 3 a" MTL STUDS 16" OC AND 2"X2'° STEEL PIPES WITH 4" LUAN PLYWOOD ON BOTH SIDES TO SPECIFIED � HEIGHT. � �„�>'c CROSSHATCH INDICATES WALLS TO BE INSULATED. PROVIDE R13 MINIMUM BATT INSULATION. nai ieir�inni DINING ROOM NORTH '� SCALE: 1/4" = 1' KEY NOTES O EXISTING DEMISING WALL. PATCH AND REPAIR GYP. BD. AS REQUIRED TO MAINTAIN EXISTING RATWG. CONFIRM WALL CONSTRUCTION AND NOTIFY PSW OF ANY DISCREPANCIES OR ISSUES. zO EXISTING STRUCTUR,4L BUILDING COMPONENTS (COLUMNS, BEAMS, TRUSSES) TO REMAIN. MAINTAW EXISTWG RATING AS REQ'D BY LOCAL CODES. O ELECTRICAL PANELS. REFER TO ELECTRICAL DR,4WINGS ONEW ALUMINUM STOREFRONT BY TENANT G.C. TO MATCH ADJACENT BUILDING STANDARD. OALIGN MUSICIAN BOOKCASE W/ FACE OF WALL. Os NOT USED. O NOT USED. Oa G.C. CONSTRUCTED DIEWALL WITH CASEWORK PANELS AT SERVICE COUNTER. REFER TO SHEET A1.5. Os FR,4MED OPENING WITH 11-1(2" CURB FOR REACH-IN COOLE COORDINATE WITH EQUIPMENT. REFER TO DETAIL 04/A5.0. �o CLOSURE ANGLE. SEE DETAIL 09/A5.0. t� PROVIDE CONTINUOUS BLOCKING IN PARTITION FOR WALL-HUNG LAVATORY; GR,46 BARS, BABY CHANGING STATION, ETC. REFER TO ENLARGED PLAN DETAIL13/A1.6 �z EXISTING ALUMINUM STOREFRONT 13 OVERHEAD CABINETS AT BACKLINE, REFER TO INTERIOR ELEVATIONS FOR LOCATION: PROVIDE BLOCKING IN WALL. 14 STAINLESS STEEL CORNER GUARD 13 NOT USED �s PROVIDE BLOCKING IN WALL FOR WALL HUNG MENU BOARD AND BOH SHELVING. SEE INTERIOR ELEVATIONS FOR MORE INFORMATION. GENERAL NOTES A. GC TO VERIFY ALL DIMENSIONS AND NOTIFY PSW CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. B. CONTRACTORS SHALL NOT SCALE THESE DR,4WINGS FOR CONSTRUCTION PURPOSES. C. ALL DIMENSIONS ARE TAKEN FROM FACE OF FINISH WALL & INSIDE OF DOOR JAMB U.N.O. D. REFER TO SHEET A1.4 FOR FURNITURE, EQUIPMENT & SHELVWG. E. REFER TO PLUMBING SHEETS FOR FIXTURE LOCATIONS & SPECIFICATIONS. F. REFER TO SHEET A2.0 FOR DOOR SCHEDULE AND DETAILS. G. ALL MEANS OF EGRESS DOOR OPENING HARDWARE SHALL BE OPERATED BY A SINGLE HAND WITHOUT MEANS OF TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. ALL DOORS EQUIPPED WITH PANIC HARDWARE MUST MAINTAIN A 32" CLEAR WIDTH. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED: A. 8.5 L.B.F. (37.7N) FOR EXTERIOR DOORS. B. 5.0 L.B.F. (22.2N} FOR INTERIOR DOORS. H. DOORS INDICATED AS PART OF THE REQUIRED MEANS OF EGRESS SHALL HAVE HARDWARE WHICH IS READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR SPECIAL EFFORT. J. PROVIDE FIRE TREATED WOOD BLOCKING WHERE REQUIRED. SAPI'�1Rt1[�1 SMQP,� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 NNVW.POTBELLY.COM � /'._ GPD GROUP, WC. 520 South Main Street, Suite 2531 Alvon, OH 44311 330.572.210� Fax: 330.5721102 O O � W H � � Q � J N J M � O � J � �p °° W d- o Z �' �C � z w U � W � � � � � Z � LN{� � w Z � Q � � U a ,�°��e" � s rf°9a�„ A" �1, ^e 9g� 0� : 1 q y e ; , �;; ` ., �,� ., � ;, ., � : , � � .. e � D �'3 '- � � • � d! ' �: SHEET TITLE CONSTRUCTION PLAN SHEET NUMBER A1.1 a c � O � � 3A � 4A WALL TYPE LEGEND EXISTING CONSTRUCTION TO REMAIN, PATCH & REPAIR TO LIKE NEW CONDITION � PARTIA SHEIGHT WALL : 5A o 20 GA 3$ MTL STUDS 16 OC AND 2 X2 STEEL PIPES WITH 1/2 PLYWOOD ON BOTH SIDES TO SPECIFIED HEIGHT FULL HEIGHT PARTITION WALL: BELOW. REFER TO WALL SECTIONS ON A5.4 FOR MORE INFORMATION ON CONSTRUCTION. APPLY CEMENT � 20 GA 3 8" MTL STUDS 16" OC WITH 8" TYPE "X" GWB ON BOTH SIDES TO DECK OR 6" ABOVE CLG. IF APPLICABLE. BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. DRYWALL SCREWS AT 12" OC. 45 DEGREE MTL STUD REINFORMCEMENT AT 48" OC ABOVE CLG LINE TO 56 5c 5D � 5q 1'-11" AFF 5g 2'-10" AFF 5C 4'-4" AFF gp 4'-0" AFF STRUCTURE ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. �� PLUMBING WALL TO 6" ABOVE CLG: a � 20 GA 3 5/8" MTL STUDS @ 3& 6" MTL STUDS @ 3A WITH e" GREEN BOARD ON ONE OR BOTH SIDES TO 6" ABOVE CLG: DRYWALL SCREWS AT 10" OC. 45 DEGREE MTL STUD REINFORCEMENT AT 48" OC ABOVE CLG LINE TO sA —� STRUCTURE ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. �qsrwc wau FURRED PLUMBWG WALL T0 6" ABOVE CLG: ❑ T =� 20 GA 3 5/8" MTL STUDS @ 4& 6" MTL STUDS @ 4A 16" OC WITH 8° GREEN BOARD ON ONE SIDE TO 6" ABOVE CLG. � �� DRYWALL SCREWS AT 10" OC. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFWG IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE WFORMATION. tie � 3-5/8" 18 GUAGE METAL STUDS W/ 2" FLANGE- WRAP WITH GYP. BOARD AND BEADBOARD. SEE A4.0 FOR FINISHES. 3-5/8" 1& GUAGE METAL STUDS W/2" FLANGE- WRAP WITH GYP. BOARD AND BEADBOARD. SEE A4.0 FOR FINISHES. 02 ENLARGED VESTIBULE CONSTRUCTION PLAN 01 ENLARGED SER u ______________________J _______________________ I I I I ______________________� I I � � ______________________� � � � ----------- � NOT USED. FURRED WALL TO 6" ABOVE CLG: 20 GA 2 2" MTL STUDS 16" OC WITH $" TYPE "X" GWB ON ONE SIDE T013'-0" AFF. DRYWALL SCREWS AT 12" OC. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. COOLER/FREEZER WALL: BY MANUFACTURER . PARTIAL HEIGHT WALL (QUEUING LINE WALL): `"° 20 GA 3 8" MTL STUDS 16" OC AND 2"X2"' STEEL PIPES WITH 4" LUAN PLYWOOD ON BOTH SIDES TO SPECIFIED � HEIGHT. CROSSHATCH INDICATES WALLS TO BE INSULATED. PROVIDE R13 MINIMUM BATT INSULATION. 6"20 GUAGE METAL STUD'C CHANNEL- TYP. 6" 20 GUAGE METAL STUDS @ 16" O.C. W/ 1/2" GYP BD EACH SIDE ABOVE CE LIN CONSTRUCTION PLAN SCALE: 3/8" = 1 NORTH \� SCALE: 3/8" = 1 KEY NOTES GENERAL NOTES A. GC TO VERIFY ALL DIMENSIONS AND NOTIFY PSW CONSTRUCTION MANAGER OFANY DISCREPANCIES PRIOR TO CONSTRUCTION. B. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES. C. ALL DIMENSIONS ARE TAKEN FROM FACE OF FINISH WALL & INSIDE OF DOOR JAMB U.N.O. D. REFER TO SHEET A1.4 FOR FURNITURE, EQUIPMENT & SHELVWG. E. REFER TO PLUMBING SHEETS FOR FIXTURE LOCATIONS & SPECIFICATIONS. F. REFER TO SHEET A2.0 FOR DOOR SCHEDULE AND DETAILS. G. ALL MEANS OF EGRESS DOOR OPENING HARDWARE SHALL BE OPERATED BY A SINGLE HAND WITHOUT MEANS OF TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST: ALL DOORS EQUIPPED WITH PANIC HARDWARE MUST MAINTAIN A 32" CLEAR WIDTH. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED: A. 8.5 L.B.F. (37.7N) FOR EXTERIOR DOORS. B. 5.0 L.B.F. (22.2N) FOR INTERIOR DOORS. H. DOORS INDICATED AS PART OF THE REQUIRED MEANS OF EGRESS SHALL HAVE HARDWARE WHICH IS READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR SPECIAL EFFORT. J. PROVIDE FIRE TREATED WOOD BLOCKING WHERE REQUIRED. �AN;DNtIGi1 SHQF'�a 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 � � Akron, OH 44311 330.572.2100 Fa�c: 330.572.2102 O O � W H �_/'� VJ � O � J N J M � � � J (, � °° w � o Z �' � � z w U � W � � � � � � N � w z � a � � U a ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 '�'�y0�@ �' � � � � �g��dA'o _ �� a , .'„ ��. .'�, -, � � ;' �`� � � � `l: � o-J"s= SHEET TITLE ENLARGED SERVIGE LINE PLAN SHEET NUMBER A1.1a 0 z d _ � � � � WOMEN'S TOILET ROOM 8'-6" A.F.F. HALLWAY 8'-6" A.F.F. PT-04 WALK-IN COOLER/ FREEZER 8'-0" A.F.F. MANUF � � 10'-1 8'-9" )OD DIMENSI� CENTERLINE - - - -_ _ _- �---------�. � �� lO Olt I II I I I. '�_=__�===�J r— _ _ _ — — — _ � �� �� IlO 011 II II II II L = =====J � A5.2 EQ e- 31'-91/2" 01 ENLARGED REFLECTED CEILING PLAN �AFN'C (ll IFI IW[; � nni ieirinni PREP � ROOM 10'-6" A.F.F. CL-01 02 REFLECTED� CEILING PLAN ` O �".r,,.,� LINE 10'-1" A.F.F. CL-O6 CL-08 ��,,,,,,, 10'-0" A.F.F. � A5.2 = = 5���� — --�---� DINING ROOM OPEN TO -3" �� u -1 �.�_`._�___ ENTRY VEST. 10'-0" A.F.F. PT-04 � ; =_� KEY NOTES � � � O 1'-6" X 1'-6" GYP. BOARD SOFFIT AT BAG IN THE BOX. i I ( � O2 PREFABRICATED COOLER CEILING I , � OSUBMARINE DUCT WITH ROTATWG PROPELLER. REFER ; � TO DETAIL 13/A5.2 AND MECHANICAL DRAWINGS FOR ': I MORE INFO ' � Oa NOT USED i i I I � 5O KITCHEN EXHAUST HOOD. REFER TO MECH DRAWWGS i I FOR MORE INFORMATION � � sO NOT USED , � � O NOT USED ; i i_.__._I Os MARKETING HANGING SIGN, REFER TO DETAIL OS/A5.2 v Os NOT USED �o NOT USED 11 CEILWG HUNG MARKETING SIGN/MENU. t2 NOT USED. 13 CLD TO BE USED ON TRACK FIXTURES ONtY IF REQUIRED BY CODE. ELECTRICAL ENGINEER TO VERIFY. SCALE: 3/8"=1 NORTH � SCALE: 1/4" = 1' LEGEND 2x4 VINYL CEILING TILE - WHITE GYP. BD. BULKHEAD W/ WOOD TRIM � 2' X2' LAY-IN METAL CLG. PANEL. IN METAL CEILING GRID W/ 12" X 12" PATTERN (FULL PANELS TO BE CENTERED OYER SERVICE AREA) PAINTED GYP. BD. CEILING GENERAL NOTES A. REFER TO SHEET A2.6 FOR LIGNT FIXTURE SCHEDULE B. REFER TO SHEET A2.4 FOR SIGNAGE SCHEDULE. C. COORDINATE LOCATIONS OF WALL MOUNTED J-BOXES WITH ELEVATIONS. D. ALL MECHANICAL DIFFUSERS AND SUPPLY GRILLES TO BE PAINTED TO MATCH SURROUNDW� MATERIAL. E. SPRINKLER HEADS (IF REQUIRED) WITHIN 10'-0" OF OVEN SHOULD BE HIGH HEAT RATED. F. ALL EXPOSED DUCTWORK, BEAMS, JOISTS, DECKING, PIPES, CONDUIT, ETC. AT CEILING SPACE THROUGHOUT DINING & QUEUING AREAS SHALL BE PAINTED AS NOTED. G. ALL DIMENSIONS ARE FROM WALL FINISH TO WALL FINISH. H. PROVIDE ADEQUATE STRUCTURAL SUPPORT FOR EACH FIXTURE. J. CONFIRM RECEIPT AND STORE FIXTURES UPON ARRIVAL AT SITE. K. PROVIDE AND INSTALL CONDUIT, J-BOXES, AND WIRING FOR ALL FIXTURES. L. COORDINATE LOCATIONS OF EMERGENCY LIGHTING AT BACK SERVICE LINE WITH INTERIOR ELEVATIONS. M. REFER TO DETAIL 9/A5.2 FOR PENDANT LIGHT JBOX MOUNTING DTL. N. REFER TO DETAIL 14/A5.2 FOR CEILING FAN MOUNTING DTL 0. REFER TO DETAIL 71A5.2 & 12/A5.2 FOR TRACK LIGHT MOUNTING DETAILS. � � t��- � T � � S1�NDWICH S�iQP� 222 MERCHANDISE MART PLA7A, SUITE 2300 CHICAGQ IL. 60654 P:312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 � Akron, OH 44311 330.572.2100 Fax: 330.572.2102 0 � � � U� � O � J N J M � O � J � � � W d- o z `� � � z W U � W � � � � � z � � � W Z � Q � � U a q�°�'��6p��' � �� � P��O��S��9 ���. �. � � ��� a x `� p� �: � �'... ... .. „ _L� :�?`��,� ar SHEET TITLE REFLECTED CEILING PLAN SHEET NUMBER A1.2 ROOM NAME ENTRY DINING FLOOR WALK OFF CONCRETE BASE ��� ■ •�r ROOM FINISH SCHEDULE WALLS CEILING PAWT; WALLCOVERING, WOOD APEN, PAINT PAI NT, WALLCOVERING, WOOD OPEN, PAINT CEILING HEIGHT 10'-0" OPEN QUEUING CONCRETE WOOD PAINT OPEN, PAINT OPEN SERVICE LINE QUARRY TILE QUARRY TILE CERAMIC TILE, PAINT METAL PANEL 10'-1" PREP AREA QUARRY TILE QUARRY TILE FRP, PAINT ACT 70'-6" PAI NT, HALLWAY CONCRETE WOOD WALLCOVERWG GYP. BOARD, PAINT 8'-6" WOMEN'S TOILET ROOM CERAMIC TILE CERAMIC TILE CERAMIC TILE, PAINT GYP: BOARD, PAINT g�_g�� MEN'S TOILETROOM CERAMIC TILE CERAMIC TILE CERAMIC TILE, PAINT GYP. BOARD, PAINT 8'-6" WALK-W COOLER QUARRY TILE QUARRY TILE STAINLESS STEEL STAINLESS STEEL 8'-0" WALK-IN FREEZER STAINLESS STEEL STAWLESS STEEL STAINLESS STEEL STAINLESS STEEL 8'-0" OTHER W/1A ACAi�G� T( RI E� HALLWA FT05 weoa WALK-J N COOLER/ FREEZER FT01 WB01 ne�nne COMMENTS /'1f ICI t1Al/'� •�- � ��_' •. • � 1�����������1 � � � � �:L•.e.�•.�.�.:a•�•.�$:�:a�.2.eL�: :� FT05 CONCRETE � TOPPING FT16 I r —__ —_-� I WALK OFF MAT r • u ��i�� w � � *REFER TO SHEET A2.1 FOR FINISH SCHEDULE* SIZE GROUT 6"X6" LATICRETE #45 RAVEN �"X�" LATICRETE #45 R4VEN 1"X1" LATICRETE #45 RAVEN 3'X3' SCORING I N/A WITH 1/8"W X 1/8"D MAX. 12X9 � N/A ��� ��� �w a REMARKS REFER TO ARCHITECTURAL SPECIFICATIONS SHEETS FOR INSTALLATIONINSTRUCTIONS REFER TO ENLARGED PLAN DETAIL FOR PATfERN. REFER TO ARCHITECTURAL SPECIFICATIONS SHEETS FOR INSTALLATION INSTRUCTIONS REFER TO ENLARGED PLAN DETAIL FOR PATTERN: REFER TO ARCHITECTURAL SPECIFICATIONS SHEETS FOR INSTALLATION INSTRUCTIONS REFER TO ARCHITECTURAL SPECIFICATIONS SHEETS FOR INSTALLATION AND FINISHING INSTRUCTIONS REFER TO CONSTRUCTION BINDER FOR INSTALLATION INSTRUCTIONS FT01 PT01 WB01 NB01 01 FLOOR FINISH PLAN � CRETE SCORING 'ERN START POINT / KEY N4TES O LEAVE OUT FLOOR FINISH AS NOTED OFREEZER FLOOR FINISH INCLUDED WITH COOLEWFREEZER ASSEMBLY. ONOT USED. ONOT USED. OFLOOR SINK/DRAIN LOCATION. REFER TO PLUMBING DRAWINGS FOR DETAILS. OSLOPE 1/8" PER FOOT TO DRAINS. OAPPLY BEAD OF SILICONE AROUND PERIMETER OF DINING ROOM WHERE WOOD BASE MEETS CONCRETE FLOOR. USE CLEAR SILICONE. 3AN:D1�'t4.#1 3t1(Jt'mH 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 1MMN.POTBELLY.COM � /��_ GPD GROUP, [NC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 O O � W H � c/� � 0 � O J N M � O � GENERAL NOTES w z� o � Z N A. REFER TO FINISH SCHEDULE ON SHEET A2.1 & A2.2 FOR �� � �- J m MORE INFORMATION. U � W � _ , o� � � B. ALL FLOORING AND BASE MATERIAL TO BE INSTALLED AS � PER PSW SPECIFICATIONS, NO SUBSTITUTIONS. � � W Z � Q � C. —�— LINE DESIGNATES LIMITS OF WATERPROOFING. � U a O D. ALL AREAS INDICATED TO RECEIVE WATERPROOFWG WHICH ARE NOT SLAB ON GRADE TO HAVE FULL WATERPROOFING ISSUE DATE INSTALLED AND RUN 6" UP WALL AND MILLWORK. ISSUE DATE E. ALL AREAS INDICATED TO RECEIVE WATERPROOFING WHICH DD SET 11.20.15 ARE SLAB ON GRADE TO HAVE WATERPROOFING INSTALLED 6° CD SET 12.14.15 UP WALL & MILLWORK AND 6" OUT ON FLOOR. LL REVIEW SET 12.22.15 F. ALL CUT TILES TO BE PUMICED SMOOTH. PERMIT SET 01.07.16 G. INSTALL QUARRY TILE COVE BASE AT SERVICE LWE DIE WALL AFTER CABINETRY HAS BEEN SET. � H. PROVIDE LEVELING AGENT AS DEEMED NECESSARY TO ALLOW ACCEPTABLE FINISH FOR FLOOR TILE. NORTH \� SCALE: 1/4" =1' ,ee°°° �a � � "HmAoo :`��C�� � ����'e _� } �; �` ,.a `�'* �s= i�S 4g !^ f 1F � l`.`,....au 4�i` .:�� �. SHEET TITLE FLOOR FINISH PLAN SHEET NUMBER A1.3 0 � N u z � 0 a c c Wnnn�ni�c Tt RI ■ , ►r ,1 WALK-IN COOLER/ FREEZER 01 FUKN� � uKt,� rix i uKt HNu O nncni�c ni i�i iinir_ ..� ���„�„. � ��. ��. �„ uirivicN i F'LHN ORTH � � SCALE: 1/4" = 1'-0" KEY NOTES ONOT USED. ONOT USED. O NOT USED. OPROVIDE BLOCKING IN WALL O INSTALL MANAGER'S DESK MINIMUM OF 2" OFF OF SIDE WALL. OGC TO PROVIDE AND INSTALL 4'-0" LENGTH OF STRAIGHT LWK MACHINE CHAIN, #4 SIZE AND COMBINATION PAD LOCK FOR CO2 TANK. OAPPLY SILICONE SEAL AROUND PERIMETER OF SAFE. USE CLEAR SILICONE. GENERAL NOTES A. REFER TO FFE SCHEDULES ON SHEET A2.2-A2.5 FOR TAG DESIGNATIONS. B. ALL EQUIPMENT AND INSTALLATION TO MEET SDF STANDARDS OR EQUIVALENL C. G.C. TO SET EQUIPMENT AND FURNITURE AS PER THIS SHEET. MAINTAW CLEARANCE WIDTHS AS PER ACCESSIBILITY GUIDELINES AND DIMENSIONS AS PER SHEET A0.1. D.�HATCHWG INDICATES MILLWORK ITEMS, REFER TO SHEET A1.2 FOR FURTHER INFORMATION. E. WHERE GC IS REQUIRED TO INSTALL ANY FIXED SEATING, TABLES, COUNTERS, ETC., A REMOVABLE SCREW IS TO BE TAPPED INTO FLOORING, NOT NAILED. �� �� � �- � ..._..- � � S�N>D1Ni;�}I SMOP� 222 MERCHANDISE MART PLA7A, SUITE 2300 CHICAGQ IL. 60654 P:312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /./� GPD GROUP, INC. 520 South Main Street, Suite 2531 � Akron, OH 44311 33�.572,2300 Fvc: 330.5J2.2102 O � � � C� � Q � � � N � M � O � J � � � d' �' W � Z �' z � � � � Q � —i m U � W = � � � � � � � W z � Q � �— U a 0006��v `� t� °YI aA��O 0 e�.. y �" � my. a rvPA ) $ � � a j ��e�}��n �'}Ft f P %4 � pY � •_ � .............(^'i .'a 4 `-. R. 'p.,<�i" .� � SHEET TITLE FF&E PLAN SHEET NUMBER A1.4 a � � 11ACAP� ni ici nnin . ., .,..,.. . . , HALLWA WALK-I N COOLER/ FREEZER .,�. .. �.,� ROOM LINE 01 CASEWORK PLAN CASEWORK ACCESSORIES ITEM Count A100 4 A103 2 A104 2 A105 1 A107 1 ; � ENLARGED DETAIL SCALE: 1/2" = 1'-0" ENTRY VEST. NORTH \� SCALE: 1/4" = 1' � ENLARGED DETAIL vv f SCALE: 1/2" = 1'-0" KEY NOTES tO 1 X 2 WOOD TRIM AT FINISH TRANSITION. REFER TO ELEVATIONS FOR MORE INFORMATION. Oz REFER TO ELEVATION SHEETS FOR LOCATION OF CHAIR RAIL AT TILE. O NOT USED. Oa NOT USED. O GC TO SUPPLY DURAROCK AT SERVICE LINE SIDE OF END WALL AS INDICATED. Os AFFIX MILLWORK PANELS & TOP CAP TO FACEtTOP OF DIE WALL AS PER MILLWORK SHOP DR,4WINGS. Oi 4 HIGH CHIP CUBBIE TO SIT ON WALL O COORDINATE THE LOCATION OF PANELS AND SPRAY PAINT PLYWOOD SUBSTRATE WITH BLACK PAINT TO HIDE EXPOSED REVEAL BETWEEN MILLWORK PANELS. COORDINATE AS NEEDED AND PAINT PRIOR TO PANEL W STALL Os 1" METAL SUPPORT POST. PROVIDED BY RETAIL INSTALLED BY GC. �o CHALK BOARD PANELS BETWEEN METAL SUPPORT POSTS. PROVIDED BY RETAIL, INSTALLED BY GC. 11 2" PIPE LEG SUPPORT. PROVIDED BY RETAIL INSTALLED BY GC. t2 SOLID SURFACE POS SHROUDS. INSTALLATION OF SHROUDS SHOULD BE COORDINATED WITH POS INSTALLATION. �a ADD GROMMET LOCATIONS IN FIELD AT POS COUNTER. GENERAL NOTES A. REFER TO CASEWORK SCHEDULE SHEET A2.7 & A2.8 FOR INFORMATION. B. ALL MDF TRIM TO COME PRIMED FROM VENDOR. GC TO APPLY FINAL FINISH IN FIELD. REFER TO CASEWORK SCHEDULE FOR FINISH DESIGNATIONS. C. GC TO TOUCH UP CASEWORK PIECES AS NEEDED UPON COMPLETION USING VENDOR PROVIDED TOUCH UP KIT. D. GC TO CAULK ALL EXPOSED SEAMS, JOINTS, ETC. WITH CLEAR SILICONE SEALANT. DO NOT CAULK MOVEABLE CASEWORK PIECES TO WALL. � � ��� i `-� SAN'D�►tCH SEI�P�� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P: 312.951.0600 F:312.951.0300 NNVW.POTBELLY.COM � //��� GPD GROUP, INC. 520 South Main SVeet, Suite 253i� Akron, OH 44311 330.572.2100 Faz:330.572.2102 O O �— � Cn Q � � � N J M � O � J � � � W � � Z �' � � z W U � W � � � � � z N � w � � Q o � z r— U a ��������`d y�g66B8���g������ � P� � 3 040� d�� �AP � �'.. a�"��s :'�_ i - S°� ' o ¢ :� m w ra ; ' �£ � _ � ... . , . ±., �J!" � 'sT q � . o �/0 �ft�tl � m � � � 0 SHEET TITLE CASEWORK PLAN � � 0 SHEET NUMBER A1.5 6 � m SURFACE MOUNTED SURFACE MOUNTED EQ EQ LIGHT FIXTURE LIGHT FIXTURE SURFACE MOUNTED -- CLEANWG TOILET ROOM SURFACE MOUNTED LIGHT FIXTURE GHECKLIST CABINET WALL SCONCE 1'-6" LIGHT FIXTURE WALL SCONCE COAT HOOK � i � � 3'-3" MIRROR � � MIRROR \� BABY CHAN�WG \� i� 18" H VERTICAL SOAP DISPENSER TABLE 18" H VERTICAL — PAPER TOWEL \ � DISPENSER � � GRAB BAR � � GRAB BAR PAPER TOWEL � WALL HUNG DISPENSER � � � � i 42" HORIZONTAL ' LAVATORY , 36" HO L WALL HUNG i � -Y ( �. � o i ! 1 I I I ; [ I 1 I i_ 1 � ( I I i I � I i." j � RIZONTA �,% � i ! o, i i �_ .,C � � � � i_. i i. C i i i � i_ � �' � r„ � i �� ; , _ , �RAB BAR , GRAB BAR LAVATORY , � � , a�I I i � i � 1 1 . 1�:.(.i .� I i i i � ;, �� � � `� o i;. ; 1,. I I.l � � J/ 1 __ �. �;[ I I ��� I` I i l i 1._ _ ¢ I. �( :...1 i� 1:1 , � I.' _ LOCATION OF M 1 i a l., 1 1 i ! I i � � I_.�.. , 1 , , ; i._- _ cn- cn ,a 1 : : , , ._� . ,: SANITARYNAPKIN _ , ,,. i._.; I . 1 i .._. ( , . .l_ � 1. _. [ 1_ . ._.. � ,_t I. . � .: I . .i o I , . � l r �I� . ( . � 1 � _�_ � j _� _. o�� .�_ � .� �_ �_ _��s �,..�.� �,i �.._� :.t__�,i _�_ i �._i ,_. . _., _� : y_�. � i... I 1 1. .. 1 �-BOX FOR . 1 � ( _1 1 I �' 1 ., � I , :_ I_, :v � o, o i _ I , � DISPOSAL I _ _�_1 �,, _l. _ _, �, 1_ 1 _ � I � r � �, . I , � I 1 C i = � 1 1 , 1 _ 1 i : � ._ � _.i _ � s i . . _ � � . . , . � , I ( _,. :_ _ 1 i � l m -� _ _ 1 [ _ `!' o i , I o _ a ,,, , _ � WATER CLOSET � � � i p_� o _��� I 1 1 ( � I � 1 C 1 � _ � 1 (WOMEN S ONLY) i ( _ � , M I : � . + fi�'. 1 � . � . °'' � . i . 1 <:, _ ~ "' -' M FLUSH VALVE ( � M � � 1 � 1 , 1 1.i C! i 1 •i q�, ,, � ,� ' o �_ i; ( 1 1,.1. I 1 1_.� I_ I I_,... 1 I. _� ��= N i! 1 i: 1 '._t:.. � y 1_ oj v � i � � �, � rn I � I 1 1 � l, 1_ � ( -i I �.�i�_ ��1:_ ( 1 � � � ��.1 .(� 1 I� �� �, E , �� / t . ; � i�_ I�_ -� ; � - ��[ � 1 i .�_' I � I 1: [ 3 _J I o I �: � 1 . I , ��I �� I � � i�� I � i i �_ � o , _' I t� 1 r [ I � J_� , � , 00 � TOILET PAPER � I i i � DISPENSER TOILET PAPER FLOOR MOUNTED �� 11 DISPENSER WATER CLOSET A1.6 O O O O O01 TOILET ROOM ELEVATIONS SCALE: 1/2° = 1'-0.. KEYNOTES 611 M209 9 9 3/4 P406 P210 M143 P102 M202 1O TOILET ROOM SIGNAGE - MEN & WOMEN WITH SYMBOL & BRAILLE. - REFER TO DETAIL 07lA1.6 FOR MOUNTWG LOCATION. 1'-0" 3'-6" 1'-4" M141 M201 M203 M204 _ __ __ O2 TOILET ROOM SIGNAGE - MEN & WOMEN VINYL LETTERS APPLIED TO - ----- DOOR AT A MINIMUM OF 49" A.F.F. MEASURED TO THE BASELINE OF VINYL LETTERS THE LOWEST TACTILE CHARACTER AND A MAX OF 60" A.F.F. TO THE APPLIED TO DOOR `D 1'-6" : I� _ �� ; BASELINE FO THE HIGHEST TACTILE CHARACTER. PT05 i� '� � I a' I� i � i _�, � � � � 9�� BRAILLE TOILET _ <� � u y �I- -_� I� o � I �_-_ O � � � - �/ --�--�I--- ��o i ROOMSIGN � ��� i-<� -V --- �---i � � � �--- � -i� I WT04 ��ies � � M - �'-6" - - h � �� - -E� - - � I I M200 i � OPP� I � � � � � � � � � � � � I 3'-3" I / I � - --I---�--�--��� � � � � I, , � �� �� � � � i � � �� � � ' , i � I� � i I i C A1�6 D 1 I I � � A116 � � I 1 I � � � 1 � i _ i . I ; � � � ( � � l � [ i . C 1 , � � � � � � � � � �I �� II � �I ObP OPP � � � , � WT-03 �, � ��. ��;-.(�1 1�1 _ � � � I � I1 � A II �I �� q � �I � I �� � � � i r i� �.a 1�_���. � � o i � � � _ � 1 a � 1 I � � � -' -------I�_ _-� ��� � j � OPP �--- -�--/----1-{ � � �� °�'� 1 i.' I='t 1 l 1 � "' I I� � � A I � I � � � � �� M� ��; 1�=� ��1`��i.l�!� � � � �� I I i� �� � j� S207� I i I i � � � � � � � I -� I �_ i � 1 � . � `� � � �---� ` � - ' � � ` '� � ; � INB02 � _1 ; 1_1 � I � i-. 1 � I ���� � I . � � � � �--- I I �-- i � � � - ----- ------ iI d'� ' _�-_ ` � � � — - � 3'-8,� z 3��,� z 07 S208 M207 07 M205 06 TOILET WALL FINISH ELEV. 07 TYPICAL DOOR ELEV. _ ' M2o6 _ GENERAL NOTES O SCALE: 1/2 = 1-0 O SCALE: 1/2 = 1-0 - _ OPP NOTE: PROVIDE CEMENT BOARD FROM FINISHED FLOOR TO 4'-0" AFF. A. REFER TO DETAIL 06/A1.6 FOR TYPICAL FINISH CALLOUTS IN TOILET PROVIDE GREEN BOARD FROM 4'-0" TO FINISHED CEILWG ROOMS. B. REFER TO SHEET A2.1 & A2.2 FOR FINISH SCHEDULE. C. REFER TO SHEET A2.3 AND A2.4 FOR FFE SCHEDULES. D. REFER TO ELEVATIONS THIS SHEET FOR ACCESSORY MOUNTING ' � HEIGHTS. i i � PROVIDE CLEAR - � SEALANT AT � LAVATORY TO WALL CONNECTION HOLD WATEWDRAIN � LWES AS HIGH AS a POSSIBLE _ � PROVIDE INSULATION M� Y o z AT HOT WATER AND � � Z � `n DRAIN PIPES UNDER o � o N � LAVATORY m N � . � . . � . . � . . � PROVIDE WATERPROOFWG UP WALL 6" ; 11 SINK SECTION , 12 NOT USED 13 ENLARGED TOILET ROOM PLAN SCALE: 1- 1-0 SCALE: NTS SCALE: 1 /2"=1'-0" ��� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P: 312.951.0600 F:312.951.0300 W1MN.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 � Akron, OH 44311 330.572.21� Faz: 330.572.2102� O 0 H � U) � 0 � J N M M � O � J (!� � o W Z Z � � � � Q 0- _1 m U � W = � � � � � LNC� � w z � Q � � U a <@°e°�� �a `�a`� ,a�'�a�o om< °� o � <a''� �` �� �: �� � F -, 4,4;�. r� � :a- e �.� :� a � �a � " ° � "��_ ` °��� �' � �1e6/ �,� ; � � � SHEET TITLE � ENLARGED TOILET ROOM PLANS � & DETAILS s SHEET NUMBER A1.6 � � c WOOD CASIN W300 DOOR STOP AS NOTED HARDWARE GROUPS SET #1 AT EXTERIOR ENTRY DOORS TYPE A . . (1j PR. HAGER (OR EQUAL) ROTON HINGES, TO MATCH STOREFRONT SYSTEM, UL LISTED, HAGER HINGE CO., MODEL #78Q224HD - LENGTH TO FIT DOOR, HEIGHT PER MANUFACTURER . � �(2) CLOSER, LCN, MODEL #4041 EDA W/ PA DKBZ � � (3) ALUMINUM THRESHOLD BY NATIONAL GUARD-(SUPPLIED BY G.C.) (3) PERIMETER�WEATHER STRIPPWG = NATIONAL GUARD NGP # 160V DKB (2) SWEEPS = NATIONAL GUARD 1025 VDKB WITH SILENCERS (2) 4" X 16" INT. PUSH PLATE, HAGER, #30S-UStOBSP313 (2) PANIC BAR, VON DUPRIN, #22E0-SP313 EXIT ONLY- IF REQUIRED BY CODE �� � . � (2) EXTERIOR PULL, VON DUPRIN, #230DT- SP313 (NO CYLINDER HOLE) R TR1M DETAIL SCALE: 1/2" = 1'-0° HOLLOW MET FRAME. DOOR AS SGHEDULED �G H EAD/JAM B D ETAI L OV SCALE: 3" = 1'-0" SERVICE .. . JAMB DETAIL 1 X6 WOOD CASING W308 07 H EAD D ETAI L FRP AS SCHEDULED 1X6 WOOD CASWG 2°PLYWOOD W300 1/4" SHIM SPACE 1/4" SHIM SPA 3-5/8" METAL ; WITH WOOD E FRP AS SCHEDULED Z" PLYWOOD : 1X3 WOOD JAMB W318 4" PANEL CLE� CASEWORK P 1X6 WOOD JAB CAFE DOOR 12 JAMB DETAIL SCALE: 3" = 1'-0" � FRP AS SCHEDULED 1/4" SHIM SPACE 1X3 WOOD JAMB W318 �REP SCALE: 3" = 1'-0" SERVICE SCALE: 3" = 1'-0" �$ NOT USED SERVICE SET #5 AT RESTROOM DOOR TYPE G (1) PR. HAGER BUTT HINGES, ANODIZED DARK BRONZE, UL LISTED, HAGER HINGECO,MODELii6B12794-1/2"X41/2° 10A-LENGTHTOFITDOOR HEIGHT PER MANUFACTU (1) WALL STOP, US10B, HAGER NINGE COMPANY, MODEL #236W (1) 6"x34" KICK PLATES, HAGER, MODEL #190S-10B (1) CLOSER, HAGER 5100 X RW/PA DBZ (1) ROCKWOOD 461 KICKDOWN US10B (1) PRIVACY LATCH SET (FOR RESTROOM DOORS ONLY) - FALCON T301S AVALON 613 SILENCERS SET #6 AT REAR EXIT TYPE D 1-1/2 PR. BUTT HINGES, BRASStANSI A2112, HAGER HINGE CO., MODEL �1BB12794-1/2"X41/2" 10A (2) 6"x34" KICK PLATES, HAGER, MODEL #190S-10B (1) CLOSER, HAGER 5100 X RWIPA DBZ SET #7 AT CAFE DOOR TYPE E (1) PUSH BAR- PANIC HARDWARE, VON DUPRIN #2670 (W/ ALARM) (1j THRESHOLD BY NATIONAL GUARD-DARK BRONZE ANODIZED (SUPPLIED CONTACT ELIASON FOR MORE INFORMATION BY G.C.) ITEM N0: SCPCF-RHPTBELLY (1) SWEEP NGP 1025 VDKB WITH SILENCERS ROD WAGNER: 269-615-1105 � RWAGNER@ELIASONCORP.COM (3) PERIMETER WEATHER STRIPPING, NATIONAL GUARD NGP #160V DKB (1) DOORVIEWER, IVES MODEL#U698 B3 � � t,,�� SET #8 AT PREP TO DINING DOOR TYPE G (1) PR. HAGER BUTT HINGES, ANODIZED DARK BRONZE, UL LISTED, HAGER HINGE CO., MODEL #6B1279 4 /" ``"� -1/2"X41/2" 10 A- LENGTH TO FIT DOOR HEIGHT PER MANUFACTURER (1) SIMPLEX 5021 XS WL 74441 KEYPAD LOCK (1) WALL STOP, US10B, HAGER HINGE COMPANY, MODEL #236W - (1) 6°x34" KIGK PLATES, HAGER, MODEL#1905-106 � j4 � Q�( j� j�( ��{ ���, (1j CLOSER, HAGER 5100 X RW/PA DBZ (1) ROCKWOOD 461 KICKDOWN US10B 222 MERCHANDISE MART PLAZA, SUITE 2300 (1) DOOR VIEWER, IVES MODEL #U698 B3 CHICAGQ IL. 60654 SILENCERS p:312.951.0600 F:312.951.0300 SET #9 AT SERVICE(PREP DOOR TYPE C wuuw.POTaeuv.cow� CONTACT ELIASON FOR MORE INFORMATION ITEM N0: SCP-12-RHPTBELLY ROD WAGNER 26&615-1105 ( RWAGNER@ELIASONCORP.COM � GENERAL NOTES /'._ A. ALL DOOR ACTIVATING HARDWARE SHALL BE INSTALLED BETWEEN 3'-2" A.F.F & 3'-8" A.F.F. B. PROVIDE DOOR SILENCERS (3 PER DOOR) AT ALL DOORS. ALL EXTERIOR DOOR BUTTS TO HAVE G PD G RO U P� I N C. NON-RISING PINS. ALL HARDWARE TO HAVE OIL RUBBED ANTIQUE BRASS FINISH. NO POLISHED szo 5outh Main Strcet, Suite 2531 BRASS. Akron, OH 94311 330.5721100 Fax: 330.572.2102 C. PINE OR POPLAR ARE ACCEPTABLE WOOD SPECIES FOR TRIM WHERE MDF IS NOT USED. SELECT AVAILABLE SPECIES & USE THROUGHOUT. D. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED, WOOD DOORS TO BE STAINED IN FIELD. SEE AS12 FOR MORE INFO. E. GC TO VERIFY IF EXISTING HARDWARE ( PROVIDED BY LANDLORD) MEETS CODE ON ALL EMERGENCY EXIT DOORS. IF NOT, GC TO PROVIDE AND INSTALL HARDWARE. VERIFY HARDWARE TYPE WITH PSW CONSTRUCTION MANAGER. F. G.C. TO CONTACT POTBELLY VENDOR FOR HARDWARE. BRIDGET JELONEK LAFORCE, INC. PH: 630.325.1950 x1603 EM: bjelonek@laforceinc.com DOOR, FRAME AND HARDWARE SCHEDULE NUMBER LOCATION NOMINAL FRAME DOOR HEAD JAMB THRSHLD HARDWARE REMARKS SIZE MAT PIN TYPE MAT FIN PRVD INSTL DETAIL DETAII DETAII TYPE PRVD INSTL D001 ENTRY PR 3'-0" X 8'-0" AL/G - A ALUM - L.L. L.L. - 06/A5.3 1 LL LL EXISTING HARDWARE WITH NEW CORES - CORES PROVIDED - AND INSTALLED BY UD -REFER D002 NOT USED � - - - - - - - - - � - - - TO GENERnL NOTE E n D003 DINING ! SERVICE 3'-0" X 2'-6" X 1 3/4° WD ST-3 E SC PLAM G.G G.0 - 12&13/A2.0 03/A5.3 7 G.C. G.0 DUAL ACTION DOOR SWING D004 SERVICE! PREP 3'-0" X 7'-0" X 13/4" WD ST-3 C SC PLAM G.C. G.0 07/A2A 11/A2.0 9 G.C. G.0 DUAL ACTION DOOR SWING D005 WALK-IN gYV.D. - - - V.D. V.D. - - - V.D. V.D. REFRGIERATOR D006 WALK-INFREEZER BYV.D. - - - V.D. V.D. - - - - V.D. V.D. PREP/DINING D007 3'-0" X 7'-0" X 1 3/4° HM PT-33 G SC ST-2 G.C. G.0 O6/A2.0 O6/A2.0 08/A5.3 8 G.C. G.0 (HALL) D008 WOMEN'S TOILET 3'-0" X 7'-0" X 13/4" HM PT-33 G SC ST-2 G.C. G.0 O6lA2.0 O6/A2.0 05/A5.3 5 G.C. G.0 PROVIDE HC'WOMENS' ROOM SIGNAGE p�9 MEN'S TOILET 3�_0° X 7'-0" X 1 3/4" HM PT-33 G SC ST-2 G.C. G.0 O6/A2A O6/A2.0 05lA5.3 5 G.C. G.0 PROVIDE HC'MENS' ROOM SIGNAGE D010 REAREXIT 3'-6"X7'-0" HM PT-33 D HM PT-33 L.L. L.L. O6/A2.0 06/A2.0 09/A5.3 6 LL LL ADDRESS/SIGNAGE AS REQ'D BY LL SCALE: 3" = 1'-0" DOOR TYPES FRP AS SCHEDULED 2° PLYWOOD 13 JAM B DETAIL ' SHIM SPACE :TAL STUD )OD BLOKING 'WOOD STRIP PANELCLEAT WORK PANEL 6 WOOD JAMB CAFE DOOR SCALE: 3" = 1'-0" O � �HOLLOW META FRAME PAINT PT-33 DOOR VIEWER DOOR PAINT PT-33 1" TEMPERED GLASS EXISTING HARDWARRE KICKPLATE NOT USED ELIASON-SCPCF-RHPTBELLY (LEFT-HAND SINGLE DOOR) STRAIGHT CUT TOP & BOTTOM ED�E. �,� 3'-°—�r � � � � <V � \ � O � NOT USED O � � i�i \ \ � ELIASON-SCP12-RHPTBELLY \ (SWGLE DOOR) 314" SOLID CORE LAMINATED O HOLLOW METAL FRAME PAINT PT-33 \ \ � � SOLID CORE � DOOR � STAIN ST-02 � � � O � � r � C/� Q � � J N J M � � � J (, � � w d- o z � � � z w U c� Li"i � � 1 � � H N � W z � � � � U a ��g�' � �S `�gy��, ���'��° +�v � ���emm� . g -q' ` F.'. . ,p� m . ` � ?, 5Ci'� ��;} � � P a � � : g2 iF 6 5 m 9p F e •;. F� a,oA� � � �.�.v. r P 29 � � � SHEET TITLE DOOR SCHEDULES & DETAILS SHEET NUMBER A2.0 � � � a c c PS'"SPE� GENERAL NOTES ITEM # DESCRIPTION MANUFACTURER SPECIFICATION SIZE GROUT FURN INSTALL REQD COMMENTS FLOORING A. FINISH MATERIALS VARY ON WALLS. REFER TO INTERIOR STANDARD FLOOR TILE AT SERVICE LINE & BOH; CONTACT: REFERENCE POTBELLY ELEVATIONS FOR EXACT FINISHES. NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): FT01 QUARRY TILE DALTILE OQ84-RED PAVER - SMOOTH; SKU #OQ84661 PB 6" X 6" LATICRETE #45 RAVEN GC GC NATIONAL.ACCOUNTS(c�DALTILE.COM ALTERNATE TO BE USED ONLY IF REQ'D BY LOCAL JURISDICTION; CorvTaCT B. NO SUBSTITUTIONS ALLOWED ON ANY SPECIFICATIONS. REFERENCE POTBELLYNATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): FT02 QUARRY TILE (ALTERNATE) DALTILE OQ81 - RED PAVER - SURETREAD; SKU #OQ81661 PB 6" X 6" LATICRETE #45 RAVEN GC GC NATIONa�.aCCouN7s@DA�TI�E.COnn C. REFER TO PSW FURNISHED SAMPLE FOR TROWEL TEXTURE FOR ENTRY VESTIBULE & RESTROOMS AS PER DRAWINGS; REFERENCE POTBELLY WR01 PRIOR TO APPLYWG FINISHED MATERIAL. NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): FT03 PORCELAIN TILE DALTILE KEYSTONE D317; 1" BISCUIT PORCELAIN HEXAGON SKU #D3171HEXMS1P 1" X T LATICRETE #45 RAVEN GC GC NATIONAL.ACCOUNTS@DALTILE.COM D. REFER TO SHEET A1.2 FOR CEILWG HEIGHTS. FOR ENTRY VESTIBULE & RESTROOMS AS PER DRAWINGS; REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): FT04 PORCELAIN TIIE DALTILE KEYSTONE D311; 1" BLACK PORCELAIN HEXAGON SKU #D3111HEXMS1P 1" X t" LATICRETE #45 RAVEN GC GC NATIONAL.ACCOUNTS�DALTILE.COM DIAMOND GRIND SURFACE W/ A PLANETARY HEAD DIAMOND GRIND SYSTEM. SCORE CUT SYSTEM AND INSTALL WITH MONGOOSE DECORATNE SCORE CUT 3' X 3' SCORWG WITH CAULK ALL EXPANSION JOINTS. REFER TO ARCHITECTURAL SPECIFICATIONS & FT05 CONCRETE TOPPING SCOFIELD CONCRETE SEALANT SAW SYSTEM. APPLY 2 COATS OF SEALANT. 1/8"W X 1/8"D. MAX. NA GC GC CONSTRUCTION MANUAL FOR COMPLETE SPECIFICATIONS. FT06 PORCELAIN TILE ERGON ECOLOGIK GRIGIO 24" X 24" LATICRETE #45 RAVEN GC GC CONTACT: MICHAEL MONTORSI (630) 539-4470 OR MMONTORSI@M21LTD.COM FT07 WOOD PLANK 1 1/2° FACE STAGGERED NA GC GC FOR USE ON EXISTING CONCRETE SURFACES IN NEED OF REPAIR. REFER TO fT11 CONCRETE PLOOR TOPPER/FILLER MAPEI PLANITOP X REPAIR MORTAR NA NA GC GC CONSTRUCTION MANUAL FOR FURTHER INFORMATION. USE MANUFACTURER RECOMMENDED ADHESIVE AND 1NSTALLATION METHOD. FT12 LUXURY VINYL TILE (LVT) AMTICO AROSMS43 STRIA BASALT 18" X 18" NA GC GC CONTACT RACHEL STOCKARD FOR PRICING 630-335-0939 CONTACT LOCAL IMPACT SPECIALTIES REPRESENTATIVE, CONTACT JENNY MCCARTHY FT16 WALK OFF MAT IMPACT SPECIALTIES HE�IX Z-1 TILE, BLACK WITH BLACK FRAME 12" X 9" NA GC GC FOR PRICWG 312.859.3689 CONTACT: MICHAEL MONTORSI (630) 539-4470 OR MMONTORSI@M21LTD.COM FT17 PORCELAIN TILE ERGON ARCHITECT RESIN, HONGKONG TAUPE 809G7R 32"X32" LATICRETE #45 RAVEN GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): FT18 PORCELAIN TILE DALTILE VERANDA TONES, REDLAND HILLS P531 SKU #P5016531 P 6.5" X 20" LATICRETE #45 R,4VEN GC GC NATIONAL.ACCOUNTS@DALTILE.COM BASE INTEGRAL COVE BASE; CONTACT: REFERENCE POTBELLY NATIONAL ACCOUNT WHEN WB01 QUARRY TILE BASE DALTILE P-3665 OW81 RED PAVER COVE BASE SKU #OQ81 P3365F1 PB 6" X 6" LATICRETE #45 R,4VEN GC GC ORDERING (P): 877.556.5728 ;(E): NATIONAL.ACCOUNTS@DALTILE.COM WTEGRAL COVE BASE; CAULK BASE AT FLOOR MATERIAL; CONTACT: REFERENCE ROUND TOP COVE BASE #S-3419T; BLACK K111 SEMI-GLOSS SKU POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): W602 CERAMIC TILE BASE DALTILE #K111 S3419T1 P1 4 1/4" X 6" LATICRETE #45 RAVEN GC GC NATIONAL.ACCOUNTS@DALTILE.COM WB03 WOOD BASE & SHOE RETAIL FIXTURES CASEWORK ITEM #W306 WITH CASEWORK ITEM #W307 5/8" X 5 1/4" VD GC WB04 WOOD BASE RETAIL FIXTURES CASEWORK ITEM #W325 1" x 4" NA VD GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): WB05 CERAMIC BASE (BATHROOM) DALTILE COLOUR SCHEME PC36C9T6, UPTOWN TAUPE B904 SKU #6904PC36C9TB1 P2 6" X?2" LATICRETE #18 SAUTERNE GC GC NATIONAL.ACCOUNTS@DALTILE.COM REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): WB06 CERAMIC BASE (CASEWORK) DALTILE VERANDA SOLIDS, GRAVEL P501 SKU #P50165201 P 6-1/2" X 20" LATICRETE #45 RAVEN GC GC NATIONA�.ACCOUNTS@DALTILE.COM LATICRETE #43 CHOCOLATE REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERWG (P): 877.556.5728 ;(E): WB07 PORCELAIN TILE DALTILE VERANDA SOLIDS, RAWHIDE P525 6-1/2" X 20" TRUFFLE GC GC NATIONAL.ACCOUNTS@DALTILE.COM WALLS WT01 NOT USED CUSTOM ORDER TILE. ALLOW 4 WEEKS. CONTACT: REFERENCE POTBELLY NATIONAL WT02 CERAMIC TILE DALTILE COLOR:GARDEN SPOT#0141; SEMI-GLOSS SKU #014136MOD1P2 3" X 6" LATICRETE #45 RAVEN GC GC ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): NATIONALACCOUNTS@DALTILE.COM LATICRETE #45 RAVEN: IF REQ'D BY CODE USE #18 REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): WT03 CERAMIC TILE DALTILE COLOR: BISCUIT K175, SEMI-GLOSS SKU #K17536MOD1 P4 3" X 6" SAUTERNE GC GC NATIONALACCOUNTS@DALTILE.COM BULLNOSE ALONG 6" EDGE; CONTACT: REFERENCE POTBELLY NATIONAL ACCOUNT WT04 CERAMIC TILE DALTILE BULLNOSE S-4269; COLOR: BLACK K111, SEMI-GLOSS SKU #K111 S42691 P2 2" X 6" LATICRETE #45 RAVEN GC GC WHEN ORDERING (P): 877.556.5728 ;(E): NATIONAL.ACCOUNTS@DALTILE.COM BLACK QUARTER ROUND A106; COLOR BLACK K111, SEMI-GLOSS SKU REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): WT06 CERAMIC TILE DALTILE #K111A1061 P2 3/4" X 6" LATICRETE #45 RAVEN GC GC NATIONALACCOUNTS�DALTILE.COM WT07 MOSAIC TILE PSVI�HUBBARD 1"X1" CUSTOM MOSAIC TILE 1" X 1" TBD PSW GC REFER TO DRAWINGS RITTENHOUSE SQUARE, S-4369, COLOR: BISCUIT K175 SEMI-GLOSS SKU REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): WT10 CERAMIC TILE (BULLNOSE BACKLINE) DALTILE #K175S4369MOD1 P2 3" X 6" LATICRETE #18 SAUTERNE GC GC NATIONAL.ACCOUNTS@DALTILE.COM REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): WT11 GLASS TILE (CHIP CUBBIE) DALTILE ISIS GLASS MOSAICS, CANDY APPLE RES IS19 SKU #IS1911 MS1 P 1"X 1" (12" X 12" SHEETS) �,qTICRETE #18 SAUTERNE GC GC NATIONAL.ACCOUNTS@DALTILE.COM �12 CERAMIC TILE (CHIP CUBBIE) pSW-HUBBARD CUSTOM MOSAIC TILE TBD TBD VD GC CONTACT ROCKWELL (POTBELLY WAREHOUSE) 312.279.0107 REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): WT13 MOSAIC TILE DALTILE FASHION ACCENTS, ILLUMINI LAKE F015 SKU # F015583MS1 P 5!8" X 3" LATICRETE #18 SAUTERNE GC GC NATIONAL.ACCOUNTSLdiDALTILE.COM REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): Wf14 MOSAIC TILE DALTILE FASHION ACCENTS, ILLUMINI LAKE F011 SKU #F0115858MS1 P 5/8" X 5!8" LATICRETE #18 SAUTERNE GC GC NATIONAL.ACCOUNTS@DALTILE.COM LATICRETE #43 CHOCOLATE REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ;(E): WT15 PORCELAIN TILE DALTILE TERRACE, CHERRY P104 SKU #P1046361 P 6"X36" TRUFFLE GC GC NATIONAL.ACCOUNTS@DALTILE.COM WC01 CUSTOM WALLCOVERING VARIES PSW GC WCO2 CUSTOM WALLCOVERING VARIES PSW GC WC03 CUSTOM WALLCOVERING VARIES PSW GC DRYWALL MUD APPLIED TO WALL SURFACE WITH 8" FLAT TROWEL KNIFE. LIGHT WR01 RANDOM TROWEL TEXTURE STUCCO THICKNESS. USE RANDOM PATTERN TO MATCH PSW SAMPLE GC GC FIBERGLASS REINFORCED PLASTIC FRP-01 PANELS GLASLINER (OR SIMILAR) 1200 SERIES; .090" THICKNESS; COIOR: WHITE TEXTURED 4' X 8' (OR 10') GC GC REFER TO DRAWINGS FOR HEIGHT. SEAL ALL EDGES & MOULDINGS CEILWG CL01 ACOUSTIC CEILING TILE ARMSTRONG CLEAN ROOM VL#870- WHITE, WITH 15/16" METAL SUSPENSION GRID 24" X 48" NA GC GC CL06 STAMPED METAL LAY-IN PANEL TIN MAN 12-10 VICTORIAN (LARGE) 24" X 24" NA VD GC CL07 STAMPED METAL LAY-W PANEL TIN MAN VICTORIAN (SMALL) 24" X 24" NA VD GC CUT COUNTERTOP TO FIT, V.I.F. UNDERMOUNT BOWL 15/16" ALUMINUM SUSPENDED CEILING GRID TO BE PAINTED WITH RUSTOLEUM CL08 PAINTED LAY-W CEILING GRID ARMSTRONG OR EQUAL BRIGHT COAT METALLIC FINISH , ALUMWUM 7715-830 NA GC GC COUNTERTOPS REFER TO MII.IWORK CN01 SOLID SURFACE CORIAN SAHARA - POLISHED FINISH DRAWINGS NA VD GC 49" W X 3/4" TH W/ OGEE CN02 GRANITE COUNTERTOPS QUADRO SKU #142855 EDGE NA GC GC FOUND AT HOME DEPOT REFER TO MILLWORK CN03 SOLID SURFACE LG MACCHIATO- POLISHED FINISH DRAWINGS VD GC PAINTS PT01 PAINT BENJAMIN MOORE NATURA AC-2 BERKSHIRE BEIGE - EGGSHELL FWISH GC GC PT02 PAINT BENJRMIN MOORE NATURA AC-17 SEA PINE - SEMI-GLOSS FINISH GC GC PT03 PAINT BENJAMIN MOORE NATURA 1267 RUBY DUSK - EGGSHELL FINISH GC GC SRPI-DWifif1 SHOP�a 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P:312.951.0600 F:312.951.0300 WIMN.POTBELLY.COM ' � � /��_ GPD GROUP, WC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 M � � 0 � 0 N � w m � � Z � U W O � a ma���� � eS,da��ao�s U � �� b °� > �� � a �•': _ s' �-> ° � � .� <, � �:�� M � TM 5, ,s .' � • SHEET TITLE FINISH SCHEDULE SHEET NUMBER 0 0 5 A2.1 6 c PT04 PT05 PT07 I3C�I-3 PT09 PT10 PT11 PT12 PT13 PT14 PT15 PT16 PT17 PT18 PT19 PT20 PT21 PT22 PT23 PT24 PT25 PT26 PT27 PT28 PT29 PT30 PT31 PT32 PT33 PT34 PT35 PT36 PT37 PT39 PT40 PT41 PT42 PT43 PT44 PT45 PT46 PT47 STAINS ST01 ST02 ST03 ST04 ST05 ST06 ST07 ST08 ST09 ST10 ST11 ST12 ST13 ST14 ST-15 ST-16 BRICK BR01 BR02 PAINT PAINT PAINT PAINT NOT USED PAINT PAINT PAINT PAINT NOT USED PAINT PAINT PAINT PAINT PAINT PAINT NOT USED PAINT PAINT PAINT PAINT PAINT PAINT PAINT PAINT - PAINT PAINT PAINT PAWT PAINT NOT USED PAINT PAINT PAINT PAWT PAINT PAINT PAINT SPECIALITY PAINT SPECIALITY PAINT SPECIALITY PAINT NOT USED PAINT PAWT STAIN STAIN STAIN STAW STAIN STAW STAW STAIN STAIN STAIN PAINT STAIN STAIN STAIN STAIN STAIN FULL MODULAR BRICK ; THIN BRICK BENJAMIN MOORE NATURA 944 ALBANY WHITE - EGGSHELL FINISH, SEMI-GLOSS FINISH FOR CEILING 2160-40 ROASTED SESAME SEED - EGGSHELL PINISH; SEMI-GLOSS IN TOILET BENJAMIN MOORE NATURA ROOMS BENJAMIN MOORE NATURA 2174-30 SEDONA CLAY- EGGSHELL FINISH BENJAMIN MOORE NATUR,4 BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMW MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATUR.4 BENJAMIN MOORE NATUR,4 BENJAMIN MOORE NATURA BENJAMIN MOORE NATUR,4 BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOQRE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA NOT USED BENJAMIN MOORE NATURA BENJAMIN MOORENATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA BENJAMW MOORE NATURA BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA SCUFFMASTER SCUFFMASTER SCUFFMASTER BENJAMIN MOORE NATURA BENJAMIN MOORE NATURA SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS MINWAX ZINSSER MINWAX BEHR SHERWIN WILLIAMS BENJAMIN MOORE NATURA MINWAX MINWAX MINWAX MINWAX MINWAX GLEN-GERY BRICK GLEN-GERY BRICK HC-72 BRANCHPORT BROWN - EGGSHELL FINISH 214410 GUACAMOLE - EGGSHELL FWISH 2120-10 JET BLACK - GLOSS - MARINE FINISH HC-32 STANDISH WHITE - GLOSS FINISH HC-49 MAYFLOWER RED- EGGSHELL FINISH E-22 COTTAGE RED - GLOSS FINISH E-43 ESSEX GREEN - ENAMEL ALKYD HIGH GLOSS FINISH AT EXTERIOR; EGGSHELL AT INTERIOR 2165- 20 GOLDEN MEADOW - EGGSHELL FINISH 1307 GERAMUM - EGGSHELL FINISH 2103-20 ENGLISH MANOR- EGGSHELL FINISH AC-3 TEXAS LEATHER - EGGSHELL FINISH 2020-10 BUMBLE BEE YELLOW - SEMI-GLOSS FINISH 2021-50 YELLOW LOTUS - SEMI-GLOSS FINISH 2145-20 TERRAPIN GREEN - SEMI-GLOSS FINISH 2001-10 RUBY RED - SEMI-GLOSS FINISH HC-7 BRYANT GOLD - EGGSHELL FINISH 2145-30 BROOKSIDE MOSS - EGGSHELL FINISH 2062-20 GENTLEMAN'S GRAY - EGGSHELL FINISH HG158 NEWBURG GREEN - EGGSHELL FINISH HC-136 WATERBURY GREEN - EGGSHEIL FINISH 2164-10 SADDLE BROWN - EGGSHELL FINISH 692 - JACK PINE - EGGSHELL FINISH 2118-40 SEA LIFE- EGGSHELL FINISH 2107-10 CHOCOLATE CANDY BROWN - EGGSHELL FINISH 2135-60 SUMMER SHOWER- SEMI-GL.OSS FINISH 2158-30 DELIGHTFUL GOLDEN - EGGSHELL FINISH 2175-30 RUST - EGGSHELL FINISH 215450 STRAVIF� SEMI-GLOSS 1672 ALFRESCO- EGGSHELL FINISH 697 SCENIC DRIVE- EGGSHELL FINISH 007 PINATA AMBIENT DESIGN, COLOR: TB102 (TO MATCH BM2144010) AMBIENT DESIGN, COLOR: TB101 (TO MATCH BMHC-158) AMBIENT DESIGN, COLOR: TB099 (TO MATCH BM2107-10) 2062-40 BLUE DAISY - EGGSHELL FINISH 2049-30 TEAL OCEAN - EGGSHELL FINISH S64WCY6378-4357 S64WXN1482-4357 S64WXN12787 S61 WCY6378-4357 50:50 MIX; PROVINCIAL #211 & GOLDEN OAK #210B AMBER SHELLAC; 00701 BULLS EYE TINTED POLYURETHANE; PRIME WITH PT-03, THEN (2) COATS POLYSHADES BOMBAY MAHOGHANY - GLOSS FINISH #501NATURALCEDAR MEDIUM RED; 1:1 RATIO OF RED SEDONA #222, JACOBEAN #2750 &(2) COATS AMER SHELLAC M64F533 TINT PAINT PT-10 LIGHT; IPSWICH OR GOLDEN OAK MEDIUM: PROVINCIAL OR MAHOGHANY DARK; SPECIAL WALNUT OR EBONY DARK; WATER BASED OIL MODIFIED POLYURETHANE - ROYAL WALNUT POLYSHADES BOMBAY MAHOGANY- SATIN FINISH 4-HB MOLDED FACE BRICK - BURGUNDY RANGE (DARK ROSE) SAND TEXTURE ABERDEEN THIN BRICK WITH THIN BRICK CORNERS - BURGUNDY RANGE - PAPERCUT TEXTURE GC GC GC GC GC GC GC IGC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC SUBMARINE DUCT COLOR SUBMARINE DUCT COLOR SUBMARINE DUCT COLOR SUBMARINE DUCT COLOR ALL DOORS AND TRIM UNLESS NOTED OTHERWISE REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS PROVIDE (3) COATS, SANDED BETWEEN. TYPICAL AT CEDAR PANELS & WALL PANELS AS NOTED ON ELEVATIONS. PROVIDE (3) COATS, SANDED BETWEEN. PROVIDE (3) COATS - FOR EXTERIOR USE AT CEDAR PLANKS FURNITURE STAIN FURNITURE STAIN FURNITURE STAIN GENERAL NOTES A. FINISH MATERIALS VARY ON WALLS. REFER TO INTERIOR ELEVATIONS FOR EXACT FINISHES. B. NO SUBSTITUTIONS ALLOWED ON ANY SPECIFICATIONS. C. REFER TO PSW FURNISHED SAMPLE FOR TROWEL TEXTURE WR01 PRIQR TO APPLYING FINISHED MATERIAL. D: REFER TO SHEET A1.2 FOR CEILING HEIGHTS. i �� �xrr,uw��n anurT� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P: 312 951.0600 F:312.951.0300 NNVW.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 O � r w � � � � Q � � J N J M � O f J (, � °° d' �n w � z � � � z W U � wC � _ � � C H � � � w Z � Q � � U a ,ga�0 � � � "°',��e� e , �' �°^� � �°m am £k �, � m v;� � � ,� �� �' is2 �b�i�" �� �. ,*r 0. , 3 e � ..... Q�� s �;i o� SHEET TITLE FINISH SCHEDULE � {CONT.) g SHEET NUMBER A2.2 � s � ' ' � . � ' 1 ' E103 SLIDING DOOR ASSEMBLY W/ SHELVES ARDCO CUSTOM SHELVES -(7) FLAT SME ON 1u S�oPE w�o o�v�oERs E Q U I PM E NT SC H E D U LE 1 BLACK EPDXY VD VD REFER TO PLAN FOR ROUGH OPENING DIMENSIONS- SEE VENDOR CUTSHEET FOR INFO E105 REFRIGERATED FRONT LOAD STATION TRUE TPP-A4D-2 W( 5/S BUMPER 1 300 SERIES S!S VD VD 120/1 8.6 5-15P W/ 5" CASTERS. E106 REFRIGER4TED DRESS STATION TRUE TSSU-27-12M-C 3 300 SERIES S/S VD VD 120H 4.9 �r75P W/ 5" CASTERS. E107 REFRIGERATEDDRESS/SALADSTATION R4NDELL 9412-32D-7 2 S/S VD VD 120/1 5.5 S15P W/21/2"CASTERS. E128 3T' ICE-CREAM DIPPING CABINET NELSON 6DIP 1 S/S & WHITE ENAMEL VD VD 115V 8 E130 WORKTOP REFRIGER4TOR TRUE TUG27 1 S/S VD VD 115/60/1 3.9 S15P CONFIRM HWGE SIDE, W/SHAKE STATION MODIFICATION E201 WALL SHELF ASSEMBLY -42" METRO (2) 42" W DOUBLE TIER - METROSEAL WALL SHELVES WITH SMARTWALL COMPONENTS y GREEN EPDXY VD VD 18' D UPPER SHELF,14" D LOWER SNELF - SEE ELEVATIONS FOR MOUNTINGHEIGHTS. PROVIDE BLOCKING IN WALL. E205 DRY STORAGE SHELVING W/ CASTERS- 36" W FOCUS SHELVES FF1836G W/ 4 TIERS POSTS: FGN086G 86"H 2 GREEN EPDXY VD VD INCLUDES CASTERS: FSCASTS E2W DRY STORAGE SHELVING W/ CASTERS- 48" W FOCUS SHELVES: FF1848G W/ 4 TIERS POSTS: FGN086G 86"H 2 GREEN EPDXY VD VD INCLUDES CASTERS: FSCASTS f208 MEATBALL WARMER WIRE SHELVING W/ CASTERS FOCUS SHELVES: Ff1430C W/ 2 TIERS, (1) S/5 FLAT SOLID SHELF POSTS: FGN033C 33"H 1 S/S VD VD INCLUDES: 1430FS, FGN033C & PSCASTS E209 SALAD SHELP ELKAY SSP TOP MOUNT SHELF FOR RANDELL UNIT 2 S/S VD VD E210 WRAPPWG PAPER SHELF ELKAY 121/2" X 271/2" SHELF W/ DIVIDER & BRACKETS 3 5/S VD VD E213 STAWLESS STEEL WALL SHELF- 24" ADVANCE TABCO WS-KD-24X 2 S/S VD VD 11 1/8°W X 2' E214 MOBILE DUNNAGE RACK 36" FOCUS FFMDR1836GN-18" X 36° X 13.5 H" 1 GREEN EPDXY VO VD E215 MOBILE DUNNAGE RACK 48" FOCUS FFMDR1848GN 18" X 48° X 13.5 H" 1 GREEN EPDXY VD VD USED AT WALK-IN FREEZER & BREAD BOX STORAGE E219 CHEMICAL SHELF-14" X 24" FOCUS SHELVES: FF1424G W/ 6 TIERS POSTS: fGN086G 1 GREEN EPDXY VD VD COOLER SHELVING, INCLUDES CASTERS: FSCAST5 E221 WALK-IN WIRE STOR4GE SHELF-18" X 36" FOCUS CAMSHELVING ELEMENTS SERIES 36" - ESK1&36V W/4 TIERS; POSTS: EPK1872 6 POLYPROPYLENE VD UD COOLER SHELVING, INCLUDES CASTERS: FSCASTS E226 OVEN STAND - TURBOCHEF ELKAY CUSTOM -42" X 31" 2 S/S VD VD TO BE USED WITH E304/E304A E247 DRYING WALL SHELF ASSEMBLY - 42" METRO (2) 42" W DOUBLE TIER - METROSEAL WALL SHELUES WITH SMARTWALL COMPONENTS 2 GREEN EPDXY VD VD AT 3 COMP SINK ONLY. 18" D UPPER SHELP, 14" D LOWER SHELF - SEE ELEVATIONS FOR MOUNTING HEIGHTS. PROVIDE BLOCKWG IN WALL. E248 BUN PAN RACK CHANNEL MANUPACTURWG 401AC 2 ALUM VD VD E250 MOBILE CART FOCUS 21° x 30" 3 S/S VD VD E251 SUPPORT SHELF FOCUS 21" x 30" 1 SS VD VD E252 DUNNAGE RACK AT SODA 36" FOCUS 24" x 36" FF2436C SHELF, 7" FG007C STATIONARY POSTS 1 SS VD VD E302 MEATBALL WARMER VOLLRATH 72051 1 S/S VD VD 120l1 1600 13.3 5-15P WITH DRAW E302A MEATBALL WARMER FOR SOUP VOLLRATH 72051 1 S/S VD VD 120/1 1600 13.3 5-75P WITH DRAW E304 CONVEYER OVEN - HIGH HEAT (REGUTAR) TURBOCHEF GLOBAL OPER4TIONS HIGH h CONVEYER 2020 2 S/S VD VD 208/240 50 UL 4 PIN PLUG TO BE 60 AMP E407 SLICER BERKEL INC. X13AE 1 VD VD 175/60/1 7 W/ SLAW TRAY E402 CAN OPENER EDLUND 1S 1 S/S VD VD SECURE TO UNDERSIDE OF TABLE E403 SCALE EDLUND DS SERIES II- DS-10-PB #53300 3 S/S VD PSW 115V AC ADAPTER INCLUDED E404 FAX MACHINE BROTHER MFC-7440N 1 � VD VD COORDINATE INSTALL WITH RTG FOR NEW STORES, PSW IT SUPPORT POR EXISTING STORES E405 SAFE CORPORATE SAFE SPECIAUSTS B3121 DM 1 HAMMER-TONE VD VD E406 POS R401ANT SYSTEMS P1520 3 VD VD COORDINATE INSTALL WITH RTG FOR NEW STORES, PSW IT SUPPORT FOR EXISTING STORES E409A SODA RACK & CARBONATOR - UNDER CABINET PROPITMASTER DISPLAYS, INC. BIB FLEX RACK SYSTEM, 28" W X 16" D X74" H, ITEM #44239 WITH WALL MOUNT ITEM #44250 1 CHROME VD VD BAG IN THE BOX UNDER SODA CABINET E410 CO2 TANK 1 VD VD GC TO PROVIDE AND INSTALL 4'-0" STRAIGHT LWK CHAIN #4 SIZE AND COMBO PAD LOCK E427 COUNTER MOUNTED BLENDER BLENDTEC A1-08Q-03S SMOOTHER Q15 WILDSIDE 2 VD VD 95 PROVIDE (3) WILDSIDE JARS &(3) RED SPATULAS PER BLENDER FURNITURE SCHEDULE ITEM # DESCRIPTION MANUFACTURER MODEL # Count FINISH FURN INSTALL COMMENTS F100 24" X 28" TABLE RETAIL FIXTURE ' 3 ST-12 VD GC F101 24" X 28" TABLE RETAIL FIXTURE 2 ST-13 VD GC F102 24" X 28" TABLE RETAIL FIXTURE 2 ST-14 VD GC F103 24"X28"TABLE PSW-HUB 1 CUSTOM PSW-HUB GC F109 28" X 46" TABLE RETAIL FIXTURE 2 ST-13 VD GC F112 24"ROUNDTABLE PSW-HUB 3 CUSTOM PSW-HUB GC F115 42" ROUND TABLE PSW-HUB 2 CUSTOM PSW-HUB GC F117 STAND UP COUNTER RETAIL FIXTURE 1 ST-13 VD GC SEE PLAN A1 A FOR LENGTH F118 OVALFAMILYTABLE PSW-HUB 1 CUSTOM PSW-HUB GC SIZE5'-6"X3'-0" F9qg OUTDOORTABLE(ALUMINUM)24" POURSEASONS P&ALTABLE-24 1 ALUMINUM VD GC F�pg OUTDOORTABLE(ALUMINUM)32" FOURSEASONS P&ALTABLE-32 6 ALUMINUM VD GC F200 SHORT CAST IRON BASE BARN FURNITURE DRDFDS24 8 BLACK WRINKIE WROUGHT IRON VD GC F203 ADALEGS BARNFURNITURE DRDHC2205 2 BLACK VD GC SETOF2,TYPICALATADATABLE F204 SINGLE PIPE W/ WALL CLEAT RETAIL FIXTURE 5 BLACK VD GC TYPICAL AT WALL BOOTH F205 CUSTOM WOOD BASE PSW-HUB 2 CUSTOM PSW-HUB GC AT NIGH TABLE F300 CHAIR - INDOOR BARN FURNITURE SCHOOLHOUSE CN3004 19 MED�UM FINISH VD GC F301 BARSTOOL BARN FURNITURE SCHOOLHOUSE ST3004 25 MEDIUM FINISH VD GC F304 CUSTOM BENCH PSW-HUB 2 CUSTOM PSW-HUB GC SEE PLAN A1.4 FOR LENGTH F311 OUTDOOR CHAIR (AL) FOUR SEASONS P&ALCHAIR 26 RESIN F407 OUTDOOR TRASH RECEPTACLE FOUR SEASONS 1 BLACK POWDER COATED VD GC F500 DECORATIVE STOVE CUSTOM POTBELLY HERITAGE ITEM 1 CUSTOM PSW-HUB PSW F503 CUSTOM BUILT SUBMARINE GC 1 PAINT PT21, PT22, PT23, PT24 � GC � ��\ 1,{r � � �� �!f 11:.Y t11 1 i� Il �i [� V F�Fhq �.:.. 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 � � Akron, OH 44311 330.572.2100 Fax: 330.572.2102 � 0 r � � � � Q ��/ L1� J N J M � O � W � � �' 0 Z �' Z � � � � Q � J m U C� W � � � � Z N � W z � Q � �— V a ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 z � a e�e00888�089689@CJg��gyB�BA � 0� 4{' �m+ � �• „�sp ''S ' 5��� l'a; - .' a f r r / ¢, � 4 R� e �..�w�:�� c , � ��w � ��e,.� .s.��j mQ 4 JJ� F B �� y � t � M +m4 t � i�g < � ��! �� ? ��o �� �� �o ryv O w SHEET TITLE FF&E SCHEDULES z � SHEET NUMBER A2.3 n c _ SIGNAGE SCHEDULE MISCELLANEOUS ITEM # MANUFACTURER DESCRIPTION Count DIMS.- HxW FURN. INSTALL COMMENTS DESCRIPTION MANUFACTURER PRODUCT # Count FINISH FURN. INSTALL COMMENTS 5100 SIGN VENDOR LOGO WALL SIGN 2 VD VD INTERNALLY ILLUMINATED 5201 PSW SOUP/SHAKE MENU BOARD 1 281/2"X 31" PSW GC M103 CUP DISPENSER SAN JAMAR C2410C18 3 VD VD M104 MOP/BROOM HANGER CARLISLE 4073100 1 VD VD 5202 PSW DESSERT MENU BOARD 1 31"X 561/2" PSW GC M106 BREAD BIN ELKAY 54"L X 10112"W, SLOPED TOP/OPENING 1 S/S VD VD INCLUDES S1S BACK PLATE & 14° SKIRT S203 PSW MENU BOARD - LARGE 1 48" x 72" PSW GC S204 PSW MENU BOARD - MEDIUM 1 36" x 55" PSW GC M107 KNIFE RACK EDLUND KR-700 2 S/S VD VD M109 30° WORK TABLE W( CASTERS ELKAY 24"D X 30"L 1 S/S VD VD INCLUDES 5° CASTERS S207 PSW CLEANING CHECKLIST 2 PSW GC LOCATED IN RESTROOMS M111 CORNER GUARD ADE U SHAPE OR L SHAPE - 42"H AT PRP / 57"H AT71LE 2 S(S VD VD WSTALLED PER PSW LOCATIONS ON DWGS S208 GC HANDICAPPED TOILET ROOM SIGN 2 GC GC S209 PSW 11 X 17 CHALKBOARD SIGN 1 17" X 11° PSW GC M112 COAT RACK EX-CELL 704SA - 6 HOOK 2 ALUM VD VD S212A PSW WALLPAPER "OFFERWGS" PANELS 2 43" x 14" PSW GC LOCATED AT BACKLINE CABINETS M113 PAN RACK NEW AGE 98485 2 ALUM VD VD M114 CUiTING BOARD / SINK COVER SAN JAMAR 1 WHITE POLY VD VD USED WITH ITEM #P204 S213 PSW COMMUNITY BOARD 1 VARIES PSW GC CH00.SE 38"X38" OR 56"X27° PROVIDE POWER AT 96" OR AS INDICATED ON M115 CUTfING BOARD - PREP ROOM SAN JAMAR C6182412WH 1 WHITE POLY VD VD ELECTRICAL DWGS. DESIGN MGR TO SPECIFY VERTICAL M121 SLICER SLAW TRAY BERKEL INC. 3875-00241 1 VD VD S2168 PSW YA GOTTA GET IT HOT' SIGN - HORIZONTAL 1 VARIES PSW GC (26X43) OR HORIZONTAL (43X26) M123 MEATBALL WARMER PANS VOLLRATH 30043, 30362, 75220 & 75230 2 S/S VD VD 5218 PSW HANGING'PHONE AHEAD' ARROW 1 24" X 24" PSW GC M131 GARBAGE TOTE - EXTR4-LARGE RUBBERMAID 9W2700-GY 1 PSW PSW 5219 PSW ORDER HERE PINGER SIGN 1 14 1/2" X 35" PSW GC CEILING MOUNTED; PROVIDE POWER AT CEILING- FLUSH M133 LOW S/S TABLE SSP, INC. 30" W X 36" D X 32" H, WITH CASTERS 1 S/S VD VD 5220 RETAIL FIXTURE HANGWG MARKETING SIGN 1 29" X 47" VD GC OUTLET AT TIN CEILING, SPOTLIGHT AT OPEN CEILING M135 EMPLOYEE LOCKER GLOBAL INDUSTRIES PENCO VANGUARDtOCKER SIX TIER, #WG480954GY � STEEL, COLOR: GRAY GC GC 12X12X 78; 6 OPENINGS. MAY SUBSTITUTE. 5221 PSW OUR SANDWICHES SIGN 1 23 3/4" X 18° PSW GC M136 COOLER CURTAIN CURTON PRODUCTS M-108-PR-0080 1 VD VD S222A PSW VINYL STORE HOURS - 24" 1 PSW GC M138 TICKET RAIL SAN JAMAR CK6536A 1 VD VD S223 PSW VINYL WINDOW MARKETING MESSAGE 1 PSW GC M141 AUTOMATIC SOAP DISPENSER POWERFOAM PUSH AT HAND SINKS 2 BLACK VD VD 5224 PSW VINYL SANDWICH MAKERS ONLY SIGN 1 PSW GC VINYL TOILET ROOM DOOR SIGNS - MEN & M142 SAFE BASE CORPORATE SAFE SPECIALIST 2820-0 1 VD VD 5225 PSW WOMEN 2 PSW GC M143 PAPER TOWEL DISPENSER - AUTOMATIC TORK H1 MATIC SYSTEM 551028A BLACK 4 MOLDED PLASTIC VD VD S300 PSW ORDER YOUR SHAKE NOW SIGN 1 29" X 19" PSW GC S301 PSW PICKLE SIGN 1 9" X 5" PSW PSW M145 4"H BACKSPLASH CUSTOM CUSTOM -4"HX27"L 18GA. S/S BACKSPLASH 1 S/S VD VD S302 PSW EMPLOYEES MUST WASH NANDS SIGN 4 6.5" X 8" PSW GC SINGLE TOPPING STATION DRY PRODUCT 87215 W/ 87217 WALL MOUNT BRACKET, 871991/9 SIZE JAR: M146 DISPSENSER SERVER PRODUCTS CLEAR, 87253 HINGE LID: CLEAR, 81516 SERVING SPOON: CLEAR 1 S/S VD VD 5303 PSW ADA ASSISTANCE SIGN WITH BELL 1 9" X 11.5" PSW GC S304 PSW NEED ASSISTANCE STROLLERIADA SIGN 1 12" X 15" PSW GC M147 PUMP RAIL COMBO SERVER PRODUCTS SR-3 82870 W/ 82120 S/S PUMPS AND 82557 JARS 1 SS VD VD S305 PSW THANKS FOR YOUR BUSINESS SIGN 1 21" X 27" PSW GC M148 CUP & LID ORGANIZER DISPENSE-RITE LID-36T 2 POLY VD VD S306 PSW CHIPS PRICE SIGN 1 12" X 1.25" PSW GC M149 STRAW HOIDER DISPENSE-RITE MSH-1 2 ACRYLIC VD VD S307 PSW COUNTERTOP MARKETING PIPE SIGN 1 22" X 11" PSW PSW 5308 PSW HOT PEPPERS PRICE SIGN 1 5" X 7" PSW PSW M150 DRAINER BOARD SSP, INC. CUSTOM -12"W X 12"D 1 VD VD S309 PSW HAND SANITIZER STAND AND SIGN 1 9" X 60" PSW GC M151 HANDS FREE SOAP DISPENSER POWERFOAM AUTOMATIC AT TOILET ROOMS 2 BLACK VD VD S310 PSW FOUNTAIN CUPILID HOLDER 1 16.5" X 5.5" PSW PSW STAINLESS STEEL TABLE 60" ON ELKAY FOODSERVICE S311 PSW LUNCH BOX COOKIE HOLDER 1 6" X 10" X 12" PSW PSW M152 CASTERS PRODUCTS WT36S60-BS - 36"D X 60" 1 VD VD S312 PSW DESSERT RISER 1 18 X 8 X 19 PSW PSW SPOKANE STAINLESS M154 DRESS STATION RISER SHELF PRODUCTS 3 S/S VD VD S313 PSW A-FRAME - EXTERIOR SIGN 1 49"x29" PSW GC PLACED OUTSIDE IN FRONT OF STORE- MOVEABLE S314 PSW A-FRAME TOPPER 1 24° X 17" PSW GC M155 BEVERAGE GLIDES ADE CUSTOM MODEL N0. RTC 1 VD VD S315 PSV�+ A-FRAME CHALKBOARDS 1 22.5" X 37° PSW GC M200 MIRROR PSW-HUBBARD CUSTOM 2 PSW GC S316 PSW P&H CUTTING BOARD 1 17" X 9" PSW GC M201 3'-6" HORIZONTAL GRAB BAR BOBRICK B-6806 SERIES 2 S/S GC GC S317 PSW FOUNTAIN DRINK PRICE HOLDER 1 11" X 625" PSW GC M202 3'-0" HORIZONTAL GRAB BAR BOBRICK B-6806 SERIES 2 S/S GC GC S318 PSW STOVE PLAQUE 1 9" X 6" PSW GC PLACE ON POTBELLY STOVE W/ PROVIDED CHAIN �1203 1'-6" VERTICAL GRAB BAR BOBRICK B-6806 SERIES 2 S/S GC GC S321 PSW PROMISE SIGN SQUARE 1 28"X28" PSW GC M204 DOUBLE ROLL TOILET TISSUE DISPENSER BOBRICK B-2740 2 CHROME VD VD S325 PSW EXTRAS 1 19"z23" hamed PSW GC M205 BABY CHANGING TABLE KOALA KARE KB200 2 CREAM GC GC S326 PSW SAVE TIME BEAT THE LINE 1 23"x19" framed PSW GC M206 COAT HOOK BOBRICK B-6707 2 S/S VD VD 5328 PSW SHAKES POSTER 1 27°x33" framed PSW GC M207 TR4SH CAN 2 CHROME PSW PSW S329 PSW DELICIOUS SIGN - LARGE 1 8' LONG PSW GC M209 SANITARY NAPKIN DISPOSAL BOBRICK B-270 1 SS VD VD S332 PSW PEACE, LOVE & POTBELLY SIGN - SMALL � 4' LONG PSW GC S333 PSW OUR SANDWICHES ARE SO GOOD 1 20" x 11° PSW GC 5334 PSW KEEP AMERICA BEAUTIFUL t 12" z 10" PSW GC S337 PSW START HERE SIGN 1 8" X 40" PSW GC S338 PSW AMERICAN FLAG 1 60" X 36" PSW GC ,�,a :.- �.,�- ^� ..:.. � Jl ���:.V �R'i��'L!1 J Rf V R" YAR...�.. 222 MERCHANDISE MART PLAZA, SUITE 230� CHICAGQ IL. 60654 P:312.951.0600 F:312.951.0300 WUVW,POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 � Akron, OH 44311 330.572.2100 Fax:330.572.2102 0 r � � � 0 Q ��/ L.t_ J N J M � � � J ( 7 �p °° � � W � z � � � z w U C� LLJ � � 1 � � �— N � W z � Q � � U a „�°ma�� � � � q�°�°a �eem/ �Ep�"2.,+� �° ^ �g� V ....`¢. W b t i.�� .o � a ;S ��i E � J y � � � ti r S Y k� � k' y� m � �'_ e" + tr� � h� . .+ . .. �.r""' :�! �i . I � ' 11 ',; SHEET TITLE FF&E SCHEDULES = (CONT) � SHEET NUMBER A2 . 4 � c _ 1 ■ PLUMBING SCHEDULE ITEM # DESCRIPTION MANUFACTURER MODEL # Count FINISH FURN. INSTALL VOLTS WATTS AMP PLUG HW. SUPPLY CW. SUPPLY TW. SUPPLY WASTE VENT COMMENTS WATER CLOSET-FLO WISE WITH AUTOMATIC MADERA fLOWISE 3249.001, ELOGATED BOWL; PROVIDE 6067 PROVIDE WITH 5905.100 HEAW DUTY AMERICAN STANDARD SEAT, FLUSH VALVE #6�65.121,002 PROVIDE JBOX IN WALL WITH LOW VOLTAGE P102 FLUSH AMERICAN STANDARD HARD WIRED SELECTRONIC FLUSH VALVE (P104) 2 WHITE GC GC 1° 4" 2° pOWER. 3C16X20 - 2-18X, 20"D X 88"L,10"H REAR SPLASH, LEFT & RT P201 THREE COMPARTMENT SINK ELKAY HAND 18" DRAINBOARDS 1 SS VD GC 3/4" 3/4" (3) 2" INDIRECT WASTE, SEE ITEM #P600 FOR FAUCET STAINLESS STEEL WORKTABLE W/ SINK - PREP P204 TABLE ELKAY SLWT30X84BS 1 SS VD GC 3!4" 3/4" 1-1/2" PROVIDE FLOOR SINK W/ INDIRECT WASTE CONNECTION. SEE ITEM #IP601 FOR FAUCET MOLDED STONE INTEGRAL DRAIN MSBID2424 W/ 830AA P205 MOP SINK WlFAUCET FIAT SERVICE FAUCET t WHITE GC GC 1!2" 1/2" 3" 2" VACUUM BREAKER P206 FLOORSINK SIOUXMANUFACTURING 861-23XW/HALFGRATE861-52i 4 GC GC 3w 2« P207 FLOOR CLEAN OUT ZURN Z-1400-ZN-GVP 5 GC GC q• VANDAL PROOF SCREWS, GLAVANIZED BODY, ROUND NICKEL BRONZE TOP P208 FLOOR DRAW SIOUX MANUFACTURING 842-3-P-NQ 4 GC GC 3" 2" PROVIDE DEEP SEAL TRAPS, ADD VEGETABLE OR MINERAL OIL TO TRAP P210 WALL-HUNG LAVATORY AMERICAN STANDARD LUCERNE 0355.012 2 WHITE VD GC 1!2" SEE ITEM #P611 FOR FAUCET. PROVIDE TEMPERING VALVE. P211 HAND SWK ELKAY SEHS-17X -17"L X 15"W X 5"D W/ SIDE SPLASHES 2 SS VD GC 1!2" 1/2° 1-1/2" 1-1/2" SEE ITEM kP6�3 FOR FAUCET. PROVIDE TEMPERING VALVE. py�q SHAKE STATION (LEPI' HAND VERSION) ELKAY CUSTOM BACK BEVERAGE COUNTER 1 VD VD 1!2" PROVIDE TEMPERING VALVE P401 CHEMICAL DISPENSER CHEMICAL DISPENSER 1629WML/1629WMR 2 VD VD 1/2" CONTAINS ALUMINUM CLORIDE. PROVIDE STAINLESS STEEL DOUBLE CHECK BACKFLOW PREVENTOR P406 TEMPERWG VAWE LEONARD 220 4 GC GC PROVIDE AT EACH HAND SINK AND LAVATORY, SET T0100° F P408 BUILT-IN DIPPERWELL T&S BRASS 0�6678-45 W/ 62282-F03 1 SS VD VD 112" 1 1/2" FAUCET INCLUDED P409 RINSER BLENDTEC JRE-610 LITTLE BLACK RINSER 1 SS VD VD NEMA P410 TEABREWER BUNN T63Q 1 VD VD 120/1/60 1780 14.8 5-1SP 1!4" B-0230-LN PAUCET; 064X 16" SWING NOZZLE W/ STREAM P600 3 COMP SINK FAUCET T&S BRASS REGULATOR 1 VD GC 1/2° 1/2° P601 PREP TABLE SINK FAUCET T&S BRASS B-0225-LN FAUCET;135X 12" SWIVEL GOOSENECK 1 VD GC 1/2" 1/2" B-1115-W FAUCET;131X SWING GOOSENECK; 1136-45 TEFLON P603 HAND SINK PAUCET T&S BRASS SEAT WASHERS 2 BRONZE VD GC 1/2" 1/2" PROVIDE TEMPERWG VALVE 8" WALL MOUNT FAUCET, ADD-ON FAUCET W/ 8" SWWG NOZZLE, CERAMIC CARTRIDGES, COMPACT SPRING & FLEX HOSE, B-0107-C SPRAY P605 SPR4YER NOZZLE T&S BRASS &0133 W/ 063X, 8-0155-LNEZ & B-0970-FEZ 1 CHROME VD GC 1/2" VALVE, VACUUM BREAKER & 6° WALL BR4CKET & LEVER HANDLES P610 SHAKE STATION FAUCET & TEMPERING VALVE T&S BRASS &0306 1 CHROME VD VD 1/2" P619 B LEVER LAVATORY FAUCET-4" SPREAD MOEN 8413SP 2 CHROME VD VD t/2" 1/2" USE FOR NEW STORES P703 WALK-IN COOLER/FREEZER- SIDE DOOR KOLPAK CUSTOM 1 VD GC REFRIGERATION HOOK-UP BY EQUIPMENT VENDOR P704 SODAACE DISPENSER CORNELIUS IDC255 1 VD VD 120/60 9.3 3/8" 3/4" P707 ICEMAKERATSODAMACHINE-AIR-COOLED HOSHIZAKIAMERICA,WC. KML-451MAH 1 SS VD VD 115l60/1 10.3 1/2" 3/4" STANDARDAIRCOOLEDUNIT COOLER REFRIGERATION SYSTEM - REMOTE 208-230/60/ ALLOWS CANDENSOR TO BE LOCATED ON THE ROOP OR OUTSIDE TO REDUCE HEAT INSIDE STORE; REFRIGERATION HOOK-UP BY P715 GOOLER KOLPAK POLARPAK 1 VD GC 1 EQUIPMENTVENDOR COOLER REPRIGERATION SYSTEM - REMOTE 20&230/60/ ALLOWS CONDENSOR TO BE LOCATED ON THE ROOF OR OUTSIDE TO REDUCE HEAT WSIDE STORE; REFRIGERATION HOOK-UP BY P716 FREEZER KOLPAK POLARPAK 1 VD GC 1 EQUIPMENTVENDOR P800 GAS WATER HEATER BRADFORD WHITE OR EQUAL EF-60T-199 1 GC GC 120l1 1.8 1" 1" REFER TO INSTALLATION GUIDE FOR MORE INFORMATION, EXPANSION TANKTO BE PROVIDED. P802 INDIRECT WASTE FUNNEL ZURN Z326 1 GC GC 2" TO BE USED AS REQUIRED BY CERTAIN JURISDICTIONS WHERE FLOOR SINKS ARE NOT ALLOWED P805 LEVER TWIST WASTES T&S BRASS B-3950 2 VD GC P807 WATER HEATER STAND NATIONAL HOT WATER PK101 1 GC GC � � � to.,� � � SkND�!'itH SHOPT� 222 MERCNANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60fi54 P: 312.951.0600 F:312.951.0300 VWJVJ.POTBELLY.COM � � /��_ GPD GROUP, tNC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 � � � �.�..� '"� � � � Q � � J N J M � � � J (, � °° �.�..� � o z � z � � � N � � Q � J m U � W = � � � Z N � w � � Q o Z� U � � a �00S�gg@888&46@i6Pg�PB�� 3 q 4 ! � V � �98�3' � �2''�'�"A A � yy n�-JO � w � �ev�� U � �' T� � y d� 'P ' " � ,': ei6 � t .. � ��, mro (9 ! i" , � m Z ," m L m g � ^�5 � � m � Li V LJ� � ¢M �q c % a sb° .00 `aa f � .fi'+�` m �mo ;�� .,>�.. • a'� '�3� BA� B 9E a � U Z m � � h O SHEET TITLE PLUMBING SCHEDULE � � 0 SHEET NUMBER A2.5 � r ■ LIGHTING SCHEDULE ITEM # TYPE MANUFACTURER DESCRIPTION Count MODEL LAMP FURN INSTALL VOLTS WATTS B.O. FIXTURE COMMENTS L100 DECORATNE PENDANT -14" CON-TEC SCHOOL HOUSE FIXTURE 5 CM5601150 W/ 8' ASSEMBLY PHILIPS 11A19/END/2700/DIM 6/1 VD GC 120 23 7'-9" AFP TO BOTTOM SEE DETAIL 09tA52 DECORATIVE ROUND CHANDELIER WITH 10 GLOBE GLASS SHADES & 10 UPRIGHT L101 DECOR4TIVE CHANDELIER CUSTOM BY PSW LIGHTS 1 CUSTOM (10) LITETRONICS 13W NEOLITE CFL LAMP/ORDER CODE: NL-13427 Vp GC 14 8'-3" AFF TO BOTTOM L102 ANTIQUE GLOBE PIXTURE CUSTOM BY PSW DEGORATIVE CHAIN HUNG FIXTURE WITH VWTAGE COLORED TEXTURE GLASS SHADE 5 CUSTOM PHILIPS EUMDT213W VD GC 120 14 7'-9" AFP TO BOTTOM SEE DETAIL 09/A52 L103 WALL SCONCE JUSTICE WALL SCONCE W/ SHADE 1 POR-8921-20-PLET-DBRZ PHILIPS 11A19/ENDI2700/DIM 6/t VD GC 42" AFF (LOW TABLES) / 54" AFF (HIGH TABLES) L104 WALL SCONCE - TOILET ROOM REJUVENATION SELMA WHITE PORCELEIN 2 A4631 / B2002 SHADE PHILIPS EL/MDT 23W Vp GC 120 23 CENTER FIXTURE ABOVE MIRROR AT 7'-0" AFF L109 CYLINDER PENDANT CON-TECH 6" CYLINDER PENDANT W/ 24" STEM KIT AND MONOPOINT 4 CF&42P-C-B / CSK24B / LA1&B PHILIPS PL-T 42W7835/4P/ALTO VD GC 13'-0" AFF TO BOTTOM SEE DETAIL 09/A52 L202 CEILING MOUNTED TOILET RM FIXTURE REJUVENATION FR4NCIS BLACK PORCELEIN W/ BLACK STRIPED SHADE 2 A7685 / 81489 BLACK STRIPED SHADE 23W GU24 LAMP W GC 120 23 NtA L203 SURFACE MOUNT COOLER STRIP LIGHT METALUX VAPORITE 1 X4 STRIP LIGHT (2) LAMP 1 VT-232-120-EB81 GE F28T8/SP35NMXIECO; ORDER CODE: 00256 GC TO PROVIDE LAMPS VDtGC GC 120 FIXTURE BY VENDOR, LAMPS BY GC L204 CEILING MOUNTED FIXTURE - BLACK REJUVENATION LOMBARD BLACK ENAMEL W/ CUSTOM GREEN STRIPE SHADE 1 A0561 W/ 304GN-10 SHADE 23W GU24 LAMP VD GC 23 L207 LED TRACK HEAD (MENU) CON-TEC PAR30 ROUND BACK CYLINDER TR4CK NEAD 8 CTL230-B SOLAIS LR30LN/25/30K(18W/1000BK VD GC IP NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07tA52 L208 LED TRACK HEAD (WALL FLOOD) CON-TEC PAR30 ROUND BACK CYLINDER TR4CK HEAD 14 CTL230-B SOLAIS LR30LN/40/30Kf18W/1000BK VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A52 L210 LINEAR TR4CK FIXTURE 48° CON-TEC LINEAR SLIM STYLE WALLWASH 3 CTL14154/HO-B PHILIPS F54T5/835M0/ALTO VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 13'-6" AFF SEE DETAIL 12lA52 METALUX 2GR8-332A-UNV-EB81-U, ZX4 (3) PHILIPS LED T8 LAMPS; PRODUCT N0: 45359-7; ORDERING CODE: 12T8/48-3500 L3�2 RECESSED 2 X 4 CO�PER METALUX, 2X4, 3 LAMP FLUORESCENT FIXTURE 4 RECESSED If 10/1 VD GC L310 6° RECESSED DOWNLIGHT (LED) CON-TEG 6" INCADESCENT HOUSING AND TRIM 5 RL38+CTR1902-WHT SOLAIS LR38/25/30Kt10258K VD GC 6" RECESSED DOWNLIGHT W/ WALLWASH L311 ��E�) CON-TEC 6" WCADESCENT HOUSING AND WALIWASH TRIM 1 RL38+CTR3807-WHT LR38/25/30K/1025BK VD GC L400 CEILWG FAN REVOLUTION LIGNTING MARISSA, WALNUT PECAN, NO LIGHT KIT, VENETIAN BRONZE 2 MA52VBT N/A VD GC 120 5 9'-0° AFF TO BOTTOM SEE DETAIL 14lA5.2 MOUNT TO TOP OF POST AT BOOKCASE NEAR L401 MUSICIAN LIGHT REJWENATION 9" OPAL CONE SCNOOLHOUSE-STYLE SHADE 1 66550 OPAL LITERONICS 13W NEOLITE CPL/ ORDER CODE: NL-13427 VD GC 13 MUSICIAN AREA TECHNICAL CONSUMER L5W EMERGENCY LIGHT PRODUCTS EMERGENCY LIGHT TCP 20760 Emergency 4 20760 EMERGENCY HALOGEN LIGHTS VD GG 120 6 TECHNICAL CONSUMER L502 EMERGENCY EXIT SIGN W/ LIGHTS PRODUCTS COMBO EMERGENCY EXIT SIGN Wt (2) HEADS 5 TCP 20723 VD GC L507 REMOTE HEAD FOR EXIT SIGN EXITRONIX REMOTE HEAD 2 Z1 P-B PAR 36 TUNGSTEN VD GC 6 OR 12 USE WITH L506 L601 WALL MOUNTED SPEAKER SOUNDTUBE WALL MOUNT SPEAKER 2 SM4001 W �/p GC TO WSTALL BACKER BOX FOR SPEAKERS L602 CEILING MOUNTED SPEAKER LOWELL 8" DUAL CONE SPEAKER ASSEMBLY 3 R SERIES VD VD GC TO INSTALL BACKER BOX FOR SPEAKERS L610 72" EXTENSION ROD REVOLUTION iIGHTING 72" IRON DOWN ROD - DR72V6 1 DR72VB VD GC FOR USE WITH L400 CEILING FAN. L611 LAMP CHANGER KIT MR. LONGARM INC. LAMP CHANGER KIT 1 B86U1 3030 VD GC L613 3' X 5' EXHAUST HOOD .ID HIGGINS SS HOOD W/ 18" ENCLOSURE PANEL 2 3624 VD GC L614 4'-0" BLACK TRACK CON-TECH 4'-0° BLACK TRACK FOR LED TRACK HEADS 3 LT-4-B W GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A52 L615 6'-0" BLACK TRACK CON-TECH 6'-0" BLACK TRACK FOR LED TRACK HEADS 8 LT-6-B VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A52 L616 8'-0" BLACK TRACK CON-TECH 8'-0" BLACK TRACK FOR LED TRACK HEADS 1 LT-B-B VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07lA52 L617 TRACK END FEED CON-TECH ENDfEED (ONE NEEDED fOR EACH TRACI� 7 LA-10-B VD GC L618 TRACK CONNECTOR CON-TECH CONNECTOR TO FIT MULTIPLE TRACKS TOGETHER 2 LA-2-B VD GC L619 TRACK CORNER CONNECTOR CON-TECH CONNECTOR TO FIT TRACKS AT A 90 ANGLE 2 LA-12-B VD GC WILL NOT BE USED IN ALL LOCATIONS. VERIFY WITH ENGINEERWG L620 CURRENT LIMITING DEVICE CON-TECH CURRENT LIMITING POER FEED 2 LA-23-RN VD GC DRAWINGS � � f'�i ,�. .��- ��.. •... SAN;D1�11CN SMIDP�M 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL 60654 P:312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Sulte 2531 Akron, OH 44331 330.572.2100 Fax: 330.572.2102 M � � 0 � 0 N � w m � � z � U W O � a ae�'°qa a �� �e�'ev� o �,w0 � �A mu � � A>�p � � � ..346 � , P,� o, o , �"1 „_� > (fY m, u�i ��-�„ $ '�i `9., co . , , .. o � z r � m � r.. :.�� ��L: c '�x'a � SHEET TITLE LIGHTING SCHEDULE _ g 0 SHEET NUMBER A2.6 n � N � ITEM # DESGRIPTION MANUFACTURER MODEL # SPECIFICATION FINISH FURN INSTALL COMMENTS A100 SHROUD SUPPORT - END, 18" H CR LAURENCE (RETAIL) SBPP08EBS CRL BRUSHED STAINLESS 18" x 1" SBPP08 SLIMLINE SERIES ROUND END STAINLESS STEEL VD GC PARTITION POST A1D1 SHROUD SUPPORT - MIDDLE, 18" H CR IAURENCE (RETAIL) SBPP08CBS CRl BRUSHED STAINLESS 18" x 1" SBPP08 SLIMLINE SERIES ROUND END STAINLESS STEEL VD GG PARTITION POST A102 SHROUD SUPPORT - ANGLE (90), 18" CR LAURENCE (RETAIL) SBPP08LBS CRL BRUSHED STAINLESS 18" x 1" SBPP08 SLIMLINE SERIES ROUND END STAINLESS STEEL VD GC H PARTITION POST A103 CHALK BOARD PANEL RETAIL FIXTURE STAINLESS STEEL VD GC A104 2" STAWLESS STEEL SUPPORT LEG RETAIL FIXTURE WOOD SUBSTRATE WITH CHALKBOARD PAINT VD GC A105 WALL CLEAT (COUNTER TOP RETAIL FIXTURE STAINLESS STEEL VD GC SUPPOR� A106 WOOD CHIP CUBBIE BASKET RETAIL FIXTURE WOOD VD GC A107 POS SHROUDS RETAIL FIXTURE SOLID SURFACE VD GC G116 SODA/ICE MACHINE SHROUD RETAIL FIXTURE PBSFC 68" HIGH - 3/4" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER STAIN: ST03; METAL PANEL: DAKOTA BLACK VD GC #RC60 SODA/ICE MACHINE SHROUD (TX 78" HIGH - 3/4" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER C117 ONLY) RETAIL FIXTURE PBSFGTX #RC60 STAIN: ST03; METAL PANEL: DAKOTA BLACK VD GC TO BE USED AT TEXAS STORES ONLY C119 DT ASSEMBLY COUNTER RETAIL FIXTURE CUSTOM SOLID SURFACE COUNTER TOP (CN03) VD GC DRIVE-THU LOCATIONS ONLY C120 DT SODA COUNTER RETAIL FIXTURE CUSTOM SOLID SURPACE COUNTER TOP (CN03) VD GC DRNE-THU LOCATIONS ONLY C122 MANAGER'S DESK RETAIL FIXTURE PBMDSK ALMONDINE MELAMINE VD GC 3/4" MELAMINE C123 RESTROOM WALI CABWET HOME DEPOT (OR EQUAL) TREW2428 FOREMOST HAVEN WALL CABINET WITH 2 DOORS, 2 ADJ: SHELVES & ESPRESSO FINISH GC GC POLISHED CHROME KNOBS MAY SUBSTITUTE FOR EQUAL SPECIFICATION. GC TO PROVIDE KEY AND LOCK. STEEL FRAME - 2X2 18GA. SQUARE TUBWG, WELDED CONSTRUCTION, STEEL FRAME: BLACK POWDER COAT, SMOOTH GRIND ALL EXPOSED WELDS; LEGS - 1/4X20 STAWLESS STEEL C131 LARGE SODA CABINET (P-LAM) RETAIL FIXTURE LEGS W/ LEVELERS; SIDE PANELS - 3/4" BALTIC BIRCH/MELAMINE ATTACHED COUNTER: CORIAN -CN01; DOORS: ST03; SIDE VD GC TO STEEL FRAME; COUNTER: CORIAN OVER PLYWOOD PANELS: ST-03; INTERIOR: ALMOND MELAMINE C132 SODA/ICE MACHINE SHROUD (P-LAM) RETAIL FIXTURE PBSFC 68" HIGH - 314" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER STAIN: ST03; METAL PANEL: DAKOTA BLACK VD GC #RC60 SODA/ICE MACHINE SHROUD (TX 78" HIGH - 3/4" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER C133 RETAIL FIXTURE PBSFGTX STAIN: ST03; METAL PANEL: DAKOTA BLACK VD GC ONL`n (P-LAM) #RC60 TO BE USED AT TEXAS STORES ONLY C134 TRASH - LARGE (PLAM) RETAIL FIXTURE PBLT PLASTIC LAMINATE VERSION, CN-01 TOP VD GC C135 TRASH - SMALL (PLAM) RETAIL FIXTURE PBST PLASTIC LAMWATE VERSION, CN-01 TOP VD GC C136 TRASH- SLIM JIM (PLAM) RETAIL FIXTURE PLASTIC LAMINATE VERSION, CN-01 TOP VD GC C138 SM SODA CABINET (P-LAM) RETAIL FIX'fURE VD GC C139 �RGE SODA CABINET W/ BIB RACK RETAILFDCTURE VD GC BELOW (P-LAM) C140 SM SODA CABINET W/ BIB RACK RETAIL FIXTURE VD GC BELOW (P-LAM) C200 ADA COUNTER FRONT PANEL RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (35-3/4"" W-VERIFY WITH SHOP DRAWINGS) STAIN: ST03 VD GC C201 ORDER COUNTER FRONT PANEL RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (41-3/4" W- VERIFY WITH SHOP DRAWINGS) STAIN: ST03 VD GC CABINET - 3/4" BIRCH PLYWOOD SIDES AND INNER BACK, 3/4" SQ SOLID WOOD EDGWG, MELAMINE BACK PANEL; COUNTER - 3/4" BIRCH PLYWOOD C202 CHIP CUBBIE (7 BAYS WIDE, 3 HIGH) RETAIL FIXTURE CUSTOM OVER 3/4" PLYWOOD SUBSTRATE W/ 3/4" BIRCH DROP EDGE STAIN: ST03 VD GC C203 DRESS COUNTER FRONT PANEL RETAIL FIXTURE CUSTOM WOOD PANEL (SIZE VARIES - VERIFY WITH SHOP DRAWINGS) STAIN: ST03 VD GC C204 POS FRONT PANEL RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (94-3/4" W- VERIFY WITH SHOP DRAWINGS} STAIN: VARIES VO GC C205 POS SIDE PANEL RETAIL FIXTURE CUSTOM CUSTOM WOODPANEL (46" W- VERIFY VNTH SHOP DRAVNNGS) STAIN: VARIES VD GC C206 END WAI.L HIGH PANEL RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (36" W- VERIFY VNTH SHOP DRAWINGS) POS HIGH PANEL FRONT - DRIVE G207 THRU RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (51-114" W- VERIFY WITH SHOP DRAWINGS) STAIN: VARIES VD GC C208 POS HIGH PANEL SIDE - DRIVE THRU RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (46" W- VERIFY WITH SHOP DRAWINGS) STAIN: VARIES VD GC C209 ORDER/LOAD FRONT PANEL RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (47 3/4"" W- VERIFY WITH SHOP DRAWINGS) STAIN: VARIES VD GC 5AN'D1MI;G�i SM�iP�, 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, Il. 60654 P:312.951.0600 F:312.951.0300 W�MN.POTBELLY.COM � � � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 49311 330.572.2300 Fax: 330.572.2102 0 0 r w � � � 0N I..L '� N �C M G � J � d�., w z � � � U C/� W � N � � z � U � M W � 0 � 0 N � W m � � z � � W 0 � a a�����+ � <`^��'�,������ n w°' e.: ' r a-. (,� �. �`. � 3 � � . . v i , , {:r � � y � � e � �L C�.s= � y � / e : SHEET TITLE CASEWORK SCHEDULE SHEET NUMBER A2.7 H 0 s a s c ITEM # DESCRIPTION MANUFACTURER MODEL # SPECIFICATION FINISH FURN INSTALL COMMENTS C300 ADA COUNTER RETAIL FIXTURE CUSTOM SOLID SURFACE COUNTER TOP MACCHIATO- POLISHED FINISH VD GC C301 ORDER COUNTER TOP CAP RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C302 NOT USED MACCHIATO- POLISHED FINISH VD GC C303 DRESS COUNTER TOP CAP RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C304 POS COUNTER RETAIL FIXTURE CUSTOM SOLID SURFACE COUNTER TOP MACCHIATO- POLISHED FINISH VD GC C304A POS COUNTER RETAIL FIXTURE CUSTOM SOLID SURFACE COUNTER TOP MACCHIATO- POLISHED FINISH VD GC C305 POS COUNTER TOP CAP (SIDE) RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C306 END WALL TOP CAP RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC POS DT HIGH WALL TOP CAP C307 (FRONT) RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C308 POS DT HIGH WALL TOP CAP (SIDE) RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C309 ORDER/LOAD TOP CAP RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C310 DT WINDOW TOP CAP RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP -CUSTOM SIZE SIDES/BACK/BOl"fOM - 3/4 BIRCH PLYWOOD; BACKSPLASH - 3/4" MAPLE TRIM; FACE FRAME - 3/4" X 2" MAPLE TRIM; CORNER TRIM - 1X1 TRIM; V200 ICE CREAM WALL CABINET RETAIL FIXTURE PBSDW PULLS - ROUND FLUSH PULL STAIN ALL' ST04; PULLS: DARK BRONZE VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK- 3/8" BEADBOARD; FACE FRAME - 3!4" X 2" MAPLE; SHELVES -(3) 3/4" PLYWOOD W/ MAPLE DROPPED SIDES/TOP/BOTTOM: ST11; BACK/SHELVES: V201 BACKLINE WALL CABINET - OPEN RETAIL FIXTURE PBUNG EDGE; DOORS - 3/4" X 2-1/4" 114" ST02 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANE� SIZE 143/8" x 431/4" (VISIBLE AREA 13-7/8" x 27-3/4") SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK- 3/8" BEADBOARD; FACE FRAME - 3/4" X 2" MAPLE; SHELVES -(3) 3/4" PLYWOOD W/ MAPLE DROPPED SIDES/TOP/BOTTOM: ST11; BACK/SHELVES: V202 BACKLWE WALL CABINET - WOOD RETAIL FIXTURE PBUNG EDGE; DOORS - 3!4" X 2-1/4" POPLAR W/ WOOD PANEL INSERTS ST02 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING W WALL; CABINETPANEL SIZE 143/8" x 43 1/4" (VISIBLE AREA 13-7l8" x 27-3/4") V203 BACKLWE SHELVING RETAIL FIXTURE 3/4" BIRCH PLYWOOD (3) W/ MAPLE D.E. ST01 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL SIDES/TOPBOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE BACKLINE WALL CABINET - OPEN - FRAME - 3!4" X 2" MAPLE; SHELVES -(3) 314" PLYWOOD Wf MAPLE DROPPED SIDES/TOP/BOTTOM: ST11; BACK/SHELVES: V204 40" RETAIL FIXTURE PBUNG EDGE; DOORS - 314" X 2-7/4" 1/4° ST02 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABWETPANEL SIZE 14-3/8" x 281/4" (VISIBLE AREA 13-7/8" x 27-314") SIDESlfOP/BOTTOM - 3/4" PLYWOOD; BACK- 3/8" BEADBOARD; FACE BACKLINE WALL CABINET - WOOD - FRAME - 3!4" X 2" MAPLE; SHELVES -(3) 3/4" PLYWOOD Wf MAPLE DROPPED SIDESlTOP/BOTTOM: ST11; BACWSHELVES: V205 40" RETAIL FIXTURE PBUNG EDGE; DOORS - 3/4" X 2-1/4" POPLAR W/ WOOD PANEL WSERTS ST02 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8" x 281/4" (VISIBLE AREA 13-7/8" x 27-3/4") SIDES/TOPlBOTTOM 3/4" PLYWOOD; BACK- 3/8" BEADBOARD; FACE BACKLINE WALL CABINET - OPEN - FRAME - 3/4" X 2" MAPLE; SHELVES -(3) 3/4" PLYWOOD W! MAPLE DROPPED SIDES/TOP/BOTTOM: ST11; BACWSHELVES: V206 30" RETAIL FIXTURE PBUNG EDGE; DOORS - 3/4" X 2-1l4" t/4" ST02 VD GC PROVIDE 3/4" FRT P�YWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8" x 1&1/4" (VISIBLE AREA 13-7/8" x 17�/4") SIDESlfOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; PACE BACKLINE WALL CABINET - WOOD - FRAME - 3/4" X 2" MAPLE; SHELVES -(3) 3/4" PLYWOOD W/ MAPLE DROPPED SIDES/TOP/BOTTOM: STt 1; BACWSHELVES: V207 30" RETAIL FIXTURE PBUNG EDGE; DOORS - 3/4" X 2-1/4" POPLAR W! WOOD PANEL INSERTS ST02 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 143/8" x 1&114" (VISIBLE AREA 137/8" x 17-3/4") V208 MENU HOLDER RETAIL FIXTURE VD GC LOCATE AS PER PLAN OR PSW DIRECTION V209 TRAYNOLDER RETAIL FIXTURE VD GC ATTACH TO SIDE OF TRASH CABINETS V210 BACKLINE WALL CABINET (PLAM) RETAIL FIXTURE PBUNG PLASTIC LAMINATE VERSION VD GC PROVIDE 314" FRT PLYWOOD BACKING IN WALL V211 ICE CREAM WALL CABINET (PLAM) RETAIL FIXTURE PBSDW PLASTIC LAMINATE VERSION VD GC PROVIDE 3/4" FRT PLYWOOD BACKING W WALL W300 DECORATIVE DOOR CASING RETAIL FIXTURE POPLAR STAINED BY RETAIL FIXTURE: ST-03 VD GC AT ALL DOORS UNLESS NOTED OTHERWISE VARIES: GC TO STAIN ST-06 AT CEDAR 1 GC TO W301 CORNER TRIM RETAIL FIXTURE 1" X 1" SOLID POPLAR CORNER TRIM (8' AT CEDAR, 4' AT BEADBOARD) PAINT: PT-04 AT BEAD BOARD VD GC W302 TOP CAP RETAIL FIXTURE 1" X 3° SOLID POPLAR TOP CAP STAINED BY RETAIL FIXTURE: ST-01 VD GC INSTALL WITH POPLAR QUARTER ROUND W303 CEDAR PLANKS - INTERIOR RETAIL FIXTURE 1" X 6" TONGUE AND GROOVE CEDAR PLANKS GC TO STAIN: ST-06 VD GC 6" W PLANKS. INSTALL 1X3 WOOD CAP WITH QUARTER ROUND TRIM PIECE AT TOP, SMOOTH SIDE TO FACE OUT W304 BEADBOARD PANELING RETAIL FIXTURE GEORGIA PACIFIC SANDED 1 V2" O.C. BEAD PATTERN STAINED BY RETAI� FIXTURE: ST-10 VD GC 4' X 8' X 11l32" PANELS W305 CHAIR RAIL RETAIL FIXTURE POPLAR GC TO PAINT: PT-04 VD GC AT TOP OF BEAD BOARD W306 QUARTER ROUND TRIM RETAIL FIXTURE POPLAR (AT CEDAR ONLY) GC TO STAIN ST-06 VD GC AT ALL WOOD BASE AND SERVICE LINE WOOD APRON/ WALLTRIM/ DOOR STAINED BY RETAIL FIXTURES: VARIES (SOFFIT W309 JAMB RETAIL FIXTURE 1° X 6" POPLAR TRIM: ST-04 / WALL TRIM ST-03) VD GC AT ALL WINDOWS AS NOTED IN ELEVATIONS W310 WOOD SILL RETAIL FIXTURE POPLAR STAINED BY RETAIL FIXTURES: ST-03 VD GC AT ALL WINDOWS AS NOTED IN ELEVATIONS STAINED BY RETAIL FIXTURES; REFER TO W312 STANDING TRIM - STAINED RETAIL FIXTURE 1" X 2" POPLAR TRIM INTERIOR ELEVATIONS FOR MORE INFORMATION VD GC REFER TO ELEVATIONS PAINTED BY GC; REFER TO INTERIOR W312A STANDING TRIM - PAINTED RETAIL FIXTURE 1" X 2" POPLAR TRIM ELEVATIONS FOR MORE INFORMATION VD GC REFER TO ELEVATIONS STAINED BY RETAIL FIXTURES: VARIES (SOFFIT W313 TRIM CAP RETAIL FIXTURE 2" X 2" SOLID POPLAR TRIM: ST-04 / WALL TRIM ST-03) VD GC AT TOP OF DOOR HEADS AS NOTED IN ELEVATIONS W314 PLINTH BLOCK AT COOLER TRIM RETAIL FIXTURE 1-3/4" X 7-3/4" X 10" POPLAR PLINTH BLOCK STAINED BY RETAIL FIXTURES: ST-03 VD GC W315 CEDAR TOP CAP GG 2" X 8" CEDAR TOP CAP GC TO STAIN: ST-06 GC GC AT TOP OF PARTIAL HEIGHT WALL AND SILL AT COOLER W316 ROSETTE BLOCK (AT COOLER TRIM) RETAIL FIXTURE 1" X 7-3/4" X 7-3/4° TH. BULL'S EYE BLOCK WITH ROSETTE CARVING STAINED BY RETAIL FIXTURES: ST-03 VD GC AT COOLER TRIM W317 PLYWOOD PANELS GEORGIA PACIFIC GRADE "B" SMOOTH FINISH GC TO STAIN: ST-06 GC GC 4' X 8' LUAN PLYWOOD PANELS, SMOOTH ON ONE SIDE. GLUE AND INSTALL TRIM AND NAILS W318 FLAT DOOR CASING RETAIL FIXTURE 1" X 31/2" POPLAR TRIM WITH MITERED CORNER STAINED BY RETAIL FIXTURES: ST-03 VD GC DOOR TRIM IN BACK OF HOUSE AS NOTED IN ELEVATIONS .�i 1'�i ,.,- ��.. SkN:Fil�tiGN SHOPt„; ' 222 MERCNANDISE MART PLAZA, SUITE 2300 CHICAGO, IL 6�654 P: 312.951.0600 F:312.951.0300 VJN^N.POTBELLY.COM � � /��� GPD GROUP, [NC. 520 South Main Street, Suite 2531 � Akron, OH 44311 330.572.2100 Fax: 330.572.2102 M � u� 0 u� 0 N � w m � � Z U w � 0 � a � • SHEET TITLE CASEWORK SCHEDULE SHEET NUMBER A2.8 � _ 5 a � c ITEM # DESCRIPTION MANUFAGTURER MODEL # SPECIFICATION FINISH FURN INSTALL COMMENTS W319 COOLER TRIM BACK BAND RETAIL FIXTURE POPLAR STAINED BY RETAIL FIXTURES: ST-03 VD GC INSTALL AROUND COOLER OPENING AS NOTED ON ELEVATIONS W320 COOLER APRON PACKAGE PSW - HUB WOOD FRAMED CUSTOM MOSAIC TILE PANEL STAINED BY PSW-HUB PSW-HUB GC INSTALL AT APRON OF COOLER AS NOTED ON ELEVATIONS. COORDINATE DIMENSIONS WITH PSW REP W321 POLE WRAP TAMBOUR POLE WRAP 8' HIGH - VARIOUS LENGTHS AVAILABLE (12", 16" OR 48") REFER TO ELEVATIONS GC GC AVAILABLE AT HOME DEPOT AND LOWES COLUMN - CLEAR PWE SMOOTH COLUMN AND ENDS; BACK PANEL - 3/8" BEADBOARD BACK; TOPlBOTTOM/SIDES/SHELVES - 1-1/2" CONSTRUCTION W322 BOOKCASE RETAIL FIXTURE C�RADE LUMBER, PANEL INSERTS - 3!4" PLYWOOD STAINED BY RETAIL FIXTURES: ST-01 VD GC PROVIDE ELECTRICAL AS REQUIRED W323 6" CEDAR PLANKS - EXTERIOR GC 6" ROUGH SEWN CEDAR PLANKS GC TO STAIN: ST-08 GC GC W324 4" CEDAR PLANKS - EXTERIOR GC 4" ROUC�H SEWN CEDAR PLANKS GC TO STAIN: ST-08 GC GC W325 4" BEVEL BASE RETAIL FIXTURE T'X4" POPLAR VNTH BEVEL EDGE STAINED BY RETAIL FIXTURES: ST-03 GC GC AT ALL WOOD BASE W326 4" CHAIR RAIi RETAIL FIXTURE T'X4" POPLAR STAWED BY RETAIL FIXTURES: ST-03 GC GC AT ALL WOOD CHAIR RAIL ADL2 4 X 4 CEDAR POSTS GC 4" X 4" X 9' H CEDAR POSTS STAIN: ST-06 GC GC BACK POSTS AT PLATFORM ADL3 6 X 6 DECORATIVE POSTS RETAIL FIXTURE 6" X 6" X 9' H DECORATIVE POST PAINT PT-11 OR STAIN:ST-10 VD GC FRONT POST AT PLATFORM PAINTED BY GC; REFER TO INTERIOR ADL5 PIGTURE FRAME RETAIL FIXTURE 1" X 2" FLAT WOOD TRIM ELEVATIONS FOR MORE WFORMATION VD GC REFER TO ELEVATIONS ADL6 DECORATIVE WOOD PANELS GC 18" W WOOD BI-FOLD DOOR PAINT: PT-01 GC GC REFER TO ELEVATIONS ADL7 PLATFORM ABOVE BOOTH GC GC GC REFER TO ELEVATIONS 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P:312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /.._ GPD GROUP, tNC. � 520 South Main Strcet, Suite 2531 . � Akron, OH 44311 330.572.2100 Fax: 330.572.2102 0 � 0 a0�`gp98Ei1B8ABBppBF�dA � qoa�'I J c'R's f� �age � `�0 �h %A h3, �Pp'��dm N � ti ��'y v k .. 0.✓q� 9 �` �`� Fu .. 'V. 'm Q '✓ p � .. tl''1`" w � y � � _ v � � � � e f � y ^ � � r, � � � we.^ � `a�"� '� �,'sa.ja'� w � ea� . f� .r� oo � fb J 9I � U ����� , � � � 0 SHEET TITLE CASEWORK SCHEDULE SHEET NUMBER A2.9 0 � _ 5 01 EXISTING EAST ELEVATION (SIDE) SGALE: 1 /4"=1'-0" OZ �m_Q�� i �nc� i ini� EXISTING SOUTH ELEVATION (FRONT) +34'-8" T,O. PARAPET +25'-0" T.O. PARAPET +11'-0" B.O. CANOPY lol_OII FIN. FLOOR SCALE: 1 /4"=1'-0" ���_Q�� i GacG i ini� KEY NOTES 1O EXISTING STOREFRONT SYSTEM O EXISTING BRONZE ANODIZED ALUMINUM STOREFRONT ENTRANCE DOOR 3O EXISTING BRICK VENEER 4O EXISTING CMU O EXISTING EFIS VENEER SIDING O PROPOSED TENANT SIGN LOCATION 7O EXISTING CANOPY PROVIDED BY LANDLORD O8 EXISTING HOLLOW METAL DOOR W/ PEEP HOLE AT 5'-0" A.F.F. O VINYL LOGO & STORE HOURS ON DOOR GENERAL NOTES A. REFER TO SHEET A2.1 FOR FINISH SCHEDULE. NOTE: SIGNAGE UNDER SEPARATE PERMIT AND SUBMITTAL E�L`_l1ilLl;: � �;I�l: i�! 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P: 312.951,0600 F:312.951.0300 WWW.POTBELLY.COM ��� /'.� GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 J W � a U Z O 0 w � � � 0 Q O � J � � z 1..{� C/� a� N � � N � d" Z W � Q U � � � 0 � 0 N � W m � _ Z U W 0 � a ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 �0�6�' � �� "a���� . �a� . � � � �Po m� �6` " y�d�� .Z> a :� ;b1. r^±ia � �, � '��. r.i� Cd'i� q £ 3 4'.. SHEET TITLE EXTERIOR ELEVATIONS SHEET NUMBER A3.0 � 3 a z 0 w 0 urS 5 0 V K � S 4,��� T.O. WALL 2'-10" T.O. WALL 0'-0" B.O. FIN. FLR O01 ENTRY FROM SERVICE TO DINING SCALE: 3/8"=1'-0�� 4'-4° T.O. WALL 0'-0" B.O: FIN. FL 03 ENT RY FROM DINING/SERVICE SCALE: 3/8"=1'-0" � � 02 ELEVATION AT ENTRY 0 16'-6" B.O. DECK 13'-0" T.O. TRIM 10'-6" B.O. CLG. PT-02 PT-04 28 Wf 5'-5° .0. TRIM /r�ijc] 0'-0" B.O. FIN. FLR � PT-19 PT-47 WR-01 SCALE: 3/8"=1'-0" — --_— -- -- TYP. � �. r--- — ---� , , , 216 � � , � � , II ., , . . ,. i � 8 s2�s i .� Ya GOTTA i i ���� . wc-o2 � � � GET IT �-------�==—T—� . . 12 . -------i----- —�° , � , A5.0 3'-5° . . 04 ELEVATION AT DINING/SERVICE I���■�IL ��m � � OPEN BEYOND � u c :,, SCALE: 3!8"=1'-0" PT-33 KEY NOTES 1O EXISTING STOREFRONT SYSTEM TO REMAIN. O EXISTING COLUMN. INTERIOR ILLUMINATED WINDOW SIGNAGE. O3 PROVIDE POWER. REFER TO ELECTRICAL DRAWINGS. 4O ENTRY DOORS. O5 SWWGWG SERVICE DOOR. O6 DOOR TRIM, REFER TO DETAII 01/A2.0. O7 VINYL MARKETING MESSA�E ON WINDOW. O8 PROVIDE BLOCKWG W WALL OCOOLER OPENING WITH TRIM SURROUND. REFER TO DETAIL 04/A5.0 . 10 1x2 WOOD TRIM. 11 CEDAR TONGUE AND GROOVE PANELS. 12 BEADBOARD PANELS. 13 CUSTOM WALLPAPER. 14 SODA CABINET. REFER TO MILLWORK AND PLUMBING SHEETS. 15 BACK BOARD CABINET-LOWEST SHELF TO BE 6" D. 16 SERVICE LINE CABINETRY. REFER TO CASEWORK SHEET FOR INFORMATION. 17 SMALL TRASH CAN. 18 LARGE TRASH CAN. �g NOT USED. 20 BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 21 NOT USED. 22 PARTIAL HEIGHT WALL AT QUEUING LINE. 23 END WALL AT SERVICE LINE. GC TO PROVIDE %" DUROCK AT MILLWORK WALL TO RECEIVE TILE. 24 NOT USED. 25 NOT USED. 26 STANDWG TRIM 27 1X6 END TRIM 28 CHAIR RAIL. 29 CORNER MOULDING, TYPICAL AT ALL EXPOSED CORNERS. 30 SUBMARINE DUCT WITH ROTATING PROPELLER, REFER TO DETAIL 13/A5.2. 31 HVAC DUCT, PAINTED PT-19. REFER TO MECHANICAL SHEETS FOR INFORMATION. 32 MECHANICAL HOOD AT OVENS. 33 HANGING MARKETING SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 34 "YA GOTTA GET IT HOT" SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 35 SOUP/SHAKE MENU BOARD. 36 SANDWICM MENU BOARD. 37 DESSERT MENU BOARD. 38 DECORATIVE TILE PANEL AT COOLER APRON 39 PAPER TOWEL DISPENSER 40 SOAP DISPENSER 41 WALL MOUTED SERVICE SINK 42 VINYL STORE LOGO AND HOURS 43 11X17 CHALKBOARD SIGN 44 OUR SANDWICHES SIGN 45 ORDER HERE FWGER 46 SOLID SURFACE COUNTER TOP AND TOP CAP. 4� GLASS TILE ON FACE OF CHIP CUBBIE BASE. TYPICAL OF (3) SIDES. � e �,�..- ,..^' +� SAND�tECl1 SHOP� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P:312.951.0600 F:312.951.0300 VNMN.POTBELLY.COM � /��� GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax:330.572.2302 O � W � C� � Q � � J N J M �o L1� Z � � � J U C� W � � � N � Z � U� ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 SHEET TITLE INTERIOR ELEVATIONS SHEET NUMBER A4.0 � � � 0 � 0 N � w m � � z � U w O � a 0 0 s a C � KEY NOTES 1O EXISTWG STOREFRONT SYSTEM TO REMAIN. OEXISTWG COLUMN. PT-09 WTERIOR ILLUMINATED WINDOW SIGNAGE. PT-19 PT-19 PT-19 WR01 O PROVIDE POWER. REFER TO ELECTRICAL z� st z� 16'-6" 4� ENRY' DOORS. B.O. DECK s� O5 SWINGIN� SERVICE DOOR. W312 2s PT-33 O DOOR TRIM, REFER TO DETAIL 01/A2.0. -------------------- -- -- ------------ ---- ----------- ---------- ------------- TYP. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 13'-O° 7O VINYL MARKETWG MESSAGE ON WINDOW. _____ _______ _______ __________ ___-_____ ________ _ __ ------- ---- --i ------ ------- --------- ---------- ---------- ---------- — T.O.TRIM O8 PROVIDE BLOCKING IN WALL HEIGHT OF WC , TO TRIM � ALIGN W/ MULLION, TYP. 9 COOLER OPENING WITH TRIM SURROUND. � � O REFER TO DETAIL 04/A5.0 . aO 10 1x2 WOOD TRIM. � , 8'-10 3/4" WC-02 �3 ' . PT-03 11 CEDAR TONGUE AND GROOVE PANELS. WR01 12 BEADBOARD PANELS. �,; �( ; � 13 CUSTOM WALLPAPER. i i i i i PT-04 2a 305 :� ; 02 i I SODA CABINET. REFER TO MILLWORK AND �P. ' � , � A5.0 ; ( �P5 2a PT-04 14 PLUMBWG SHEETS. I�' ;� i � 15 BACK BOARD CABWET-LOWEST SHELF TO I i I � BE 6 D. , � '� �� � � ; I, � i f 303 �� 16 SERVICE LINE CABINETRY. REFER TO CASEWORK t1 W303 ,I� { �;; ;( i i� i l i ;� SHEET FOR INFORMATION. TYP. � I� �� (�' ! I � ( � � � ' 17 SMALL TRASH CAN. ' ' � �� I i ? I, I; 1 I �; � ' 0'-0" 18 LARGE TRASH CAN. 8.0. FIN. FLR 19 NOT USED. WB-04 303 � � � W304 � 2 20 � TYP. TYP. 20 S�HEETS FOR POWER REQUIREME 0 SLECTRICAL 21 NOT USED. O� E N T RY AT D I N I N G ��_ �„ 22 ENDTWALL AT SERV CE L N�EUGC TO PROVIDE 8" O SCALE` 3/8 —1 -0 23 DUROCK AT MILLWORK WALL TO RECEIVE TILE. 24 NOT USED. 25 NOT USED. 26 STANDING TRIM 27 1X6 END TRIM 31 PT-19 28 CHAIR RAIL. 29 CORNER MOULDING, TYPICAL AT ALL EXPOSED CORNERS. O30 SUBMARINE DUCT WITH ROTATING PROPELLER, REFER TO DETAII 13/A5.2. ,----------- - ----- -------------- ------------ � 31 HVAC DUCT, PAINTED PT-19. REFER TO MECHANICAL SHEETS FOR INFORMATION. ._ 32 MECHANICAL HOOD AT OVENS. �--- --- _---------------______ 33 HANGING MARKETING SIGN. REFER TO _. . _ . . - . . -- — ELECTRICAL SHEETS FOR POWER r . . . . _ REQUIREMENTS. � - _. ' � ( � � 34 "YA GOTTA GET IT HOT" SIGN. REFER TO � �. �_ �.., �� , _ �_ �"'� ELECTRICAL SHEETS FOR POWER —, — REQUIREMENTS. ,_, � — _- � � � � ---__ _____-----� � 35 SOUP/SHAKE MENU BOARD. ........... ..._ . � 36 SANDWICH MENU BOARD: 08 37 DESSERT MENU BOARD. �_ _� A5A -- - -- , , , - - 38 DECORATIVE TILE PANEL AT COOLER APRON _ _. � _ � ,.. _ , o � o � - – 39 PAPER TOWEL DISPENSER 40 SOAP DISPENSER 41 WALL MOUTED SERVICE SINK 42 VINYL STORE LOGO AND HOURS 43 11X17 CHALKBOARD SIGN W322 zo W322 zo W301 W317 W315 WB-04 44 OUR SANDWICHES SIGN 45 ORDER HERE FWGER 46 SOLID SURFACE COUNTER TOP AND TOP CAP. 02 ELEVATION AT MUSICIAN ELEVATION AT MUSICIAN 04 ELEVATION AT PARTIAL HEIGHT WALL 0 GLASSTILEONFACEOFCHIPCUBBIEBASE. SCALE: 3/8"=1'-0" O� SCALE: 3/8 –1 -0 O SCALE: 3/8"=1'-0" 47 TYPICAL OF (3) SIDES. Sf►1'I;DWt�H 5IiV1'� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P: 312.951.0600 F:312.951.0300 VNNW.POTBELLY.COM � /��_ GPD GROUP, WC. . 520 Sou[h Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2302 O f— C/) � � � J N J M � O M w � � o � 0 Z�' � � P � � N � Q � J m V C� W � � � � � z N � w z � Q � � U a ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 ��6" � S '�am, 0a�a t �R �a�e �` o a � -�f �G e.i i 4 `f # � ? , ��ee� , :.���� � � n _ ,;:= .� r ', � :_ SHEET TITLE INTERIOR ELEVATIONS SHEET NUMBER � 5 A4.1 n � s L : � C � 01 ELEVATION AT SERVICE LINE . � `1 Yt �E Yt 03 ELEVATION AT DINING/DOOR TO PREP 0 I � ELEV. AT VESTIBULE SCALE: 3/8"=1'-0" 02 SCALE: 3/8"=1'-0" �� ■� � O^ ELEVATION AT DINING/DOOR TO PREP SCALE:3/8"=1'-0" O`�' SCALE: 3/8"=1'-0" �� NOTES O EXISTING STOREFRONT SYSTEM TO REMAIN. OEXISTING COLUMN. INTERIOR ILLUMINATED WINDOW SIGNAGE. OPROVIDE POWER. REFER TO ELECTRICAL DRAWINGS. 4O ENTRY DOORS. 5O SWINGWG SERVICE DOOR. 6O DOOR TRIM, REFER TO DETAIL 011A2.0. 7O VINYL MARKETING MESSAGE ON WINDOW. 8O PROVIDE BLOCKING IN WALL OCOOLER OPENING WITH TRIM SURROUND. REFER TO DETAIL 04/A5.0 . 10 1x2 WOOD TRIM. 11 CEDAR TONGUE AND GROOVE PANELS. 12 BEADBOARD PANELS. 13 CUSTOM WALLPAPER. 14 SODA CABINET. REFER TO MILLWORK AND PLUMBWG SHEETS. 15 BACK BOARD CABINET-LOWEST SHELF TO BE 6" D. 16 SERVICE LINE CABINETRY. REFER TO CASEWORK SHEET FOR INFORMATION. 17 SMALL TRASH CAN. 18 LARGE TRASH CAN. �g NOT USED. 20 BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 21 NOT USED. 22 PARTIAL HEIGHT WALL AT QUEUING LINE. 23 END WALL AT SERVICE LINE. GC TO PROVIDE %" DUROCK AT MILLWORK WALL TO RECEIVE TILE. 24 NOT USED. 25 NOT USED. 26 STANDING TRIM 27 1X6 END TRIM 28 CHAIR RAIL. 29 CORNER MOULDWG, TYPICAL AT ALL EXPOSED CORNERS. 30 SUBMARINE DUCT WITH ROTATING PROPELLER, REFER TO DETAIL 13/A5.2. 31 HVAC DUCT, PAINTED PT-19. REFER TO MECHANICAL SHEETS FOR INFORMATION. 32 MECHANICAL HOOD AT OVENS. 33 HANGING MARKETING SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 34 "YA GOTTA GET IT HOT" SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 35 SOUP/SHAKE MENU BOARD. 36 SANDWICH MENU BOARD. 37 DESSERT MENU BOARD. 38 DECORATIVE TILE PANEL AT COOLER APRON 39 PAPER TOWEL DISPENSER 40 SOAP DISPENSER 41 WALL MOUTED SERVICE SINK 42 VINYL STORE LOGO AND HOURS 43 11X17 CHALKBOARD SIGN 44 OUR SANDWICHES SIGN 45 ORDER HERE FINGER 46 SOLID SURFACE COUNTER TOP AND TOP CAP. 4� GLASS TILE ON FACE OF CHIP CUBBIE BASE. TYPICAL OE (3) SIDES. �iAN';D1P1IGi1 S�lOPt,� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICA�O, IL. 60654 P:312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /��_ GPD GROUP, tNC. 520 South Main Sheet, Suite 2531 � � Akron, ON 44311 330.572.2100 Fax: 330.572.2102 M � Z W � U ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 � � � 0 � 0 N � w m � � z � U w 0 � a SHEET TITLE INTERIOR ELEVATIONS SHEET NUMBER 1/ � � 0 s m c � KEY NOTES 18'-O° 1O EXISTING STOREFRONT SYSTEM TO REMAIN. 2 EXISTING COLUMN. B.O. DECK s� PT-19 O WTERIOR ILLUMINATED WINDOW SIGNAGE. O3 PROVIDE POWER. REFER TO ELECTRICAL DR,4WINGS. OENTRY DOORS. — — — — O SWWGING SERVICE DOOR. ----------------- — — — — — — — — — — — — � O6 DOOR TRIM, REFER TO DETAIL 01/A2.0. 7O VINYL MARKETIN� MESSAGE ON WINDOW. O8 PROVIDE BLOCKING IN WALL s �s S202 s a� S321 �s a 212 15 �s a 212 s S204 PT-02 PT-09 10'-1 �� B.O. CEILING I—------ i � --_ WR01 Og COOLER OPENWG WITH TRIM SURROUND. r — — — � � � � REFER TO DETAIL 04/A5.0 . I � I�— --� I O I I � � N � / 27 � SIGN � I I I I I 10 1x2 WOOD TRIM. � � �_ ______ � i i � � I I � � � 11 CEDAR TONGUE AND GROOVE PANELS. �--� � � , , , , , L-------J W305 2s 12 BEADBOARD PANELS. � � � � o q PT-04 PT 04 S209 � - 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P:312.951.0600 F:312.957.0300 WWW.POTBELLY.COM ��� /��_ GPD GROUP, INC. 520 South Maln Stre�, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 5'-5° _ _ — '� � 13 CUSTOM WALLPAPER. � TA. TILE/TRIM � � � � i � 1 1 t � I 1 � I ? _ � i ' ; ( i 1 1-. ' , � , - � ,, T ( 1 � 1 1 C � � 1 - � . 1 �-' 1 I . I i ( � . 1 i 1 .� � �a w3o5 � � � � � � � ` 1 � 1� 1 1 ( I 1 1 � I I 1 SODA CABINET. REFER TO MILLWORK AND � � �(, , � l� � l E � � l 1'� ; 1 � I' �� l I_: I'_[ (_ i i L I � E � � TYP. - 14 PLUMBWG SHEETS � I � ;f� C (�,l:��I�11 �(� � �(1 — — :._ 1. 1 :,I � I— . � � � � � � � I��; — _ �. � I� p� � ` > � � � I ; ; 1:-; " , r�- �� 1 � m 1 . � T �, � � ( � I � � ��I ' � I ( , 15 BACK BOARD CABWET-LOWEST SHELF TO � � � _ , , , .� /� /� � / i i , BE 6" D. �' .� � � 1 l � � i . (_ � � � o � , � C r � � �� W304 � � � , � � � �' � ���,�` " _ - ' ' SERVICE LWE CABINETRY. REFER TO CASEWORK , � , I l, , 1 T � [:- , ao 1__ � IYP. / � j oQ (( I 16 �,, j]-- � �, �. 'I ',�:I �l-'� �_ I i �., _ �l 1 �I � � � �� �� _ �� � , i SHEET FOR INFORMATION. �� � � � � _ 1 1_ 1 _ -' i-. I 1 _ � ' � O.O � , - � ' '�" -I � ; I ( ; i � � �' 17 SMALL TRASH CAN. B.O. FIN. FLR. 18 LARGE TRASH CAN. �I/B-Q� 40 39 41 32 1 12 W304 18 WB-04 TYP. 19 NOT USED. 20 BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 21 NOT USED. 22 PARTIAL HEIGHT WALL AT QUEUING LINE. 01 ELEVATION AT SERVICE LINE BACK WALL ELEVATION AT ENTRY 23 ENDWALLATSERVICELINE.GCTOPROVIDE%�� O SCALE: 3/8"=1'-0" O� SCALE. 3(8 -1 0 DUROCK AT MILLWORK WALL TO RECEIVE TILE. O 24 NOT USED. 25 NOT USED. 26 STANDING TRIM 27 1X6 END TRIM 16'-6° 28 CHAIR RAIL. B.O. DECK 29 CORNER MOULDING, TYPICAL AT ALL EXPOSED � CORNERS. O30 SUBMARINE DUCT WITH ROTATING PROPELLER, REFER TO DETAIL 13/A5.2. 31 HVAC DUCT, PAINTED PT-19. REFER TO MECHANICAL SHEETS FOR INFORMATION. 32 MECHANICAL HOOD AT OVENS. 1� 33 HANGING MARKETING SIGN. REFER TO 10'-1 ° ELECTRICAL SHEETS FOR POWER B.O. CEILING REQUIREMENTS. 34 "YA GOTTA GET IT HOT" SIGN. REFER TO ELECTRICAL SHEETS FOR POWER 8�-6�� REQUIREMENTS. 8.0. CEILING 35 SOUP/SHAKE MENU BOARD. OPEN BEYOND � PT-09 � 36 SANDWICH MENU BOARD. O � \ � � 37 DESSERT MENU BOARD. � PT-04 Za W305 �� 38 DECORATIVE TILE PANEL AT COOLER APRON TYP. � 0 � , C----- I 39 PAPER TOWEL DISPENSER ,, � �; � � �–� � � � �2 W304 i/ �� 40 SOAP DISPENSER � I' � i � O I--- � C� � Q � � � N � M C O M C � J � �p °° d' "' W z � � � Z w U � W � � � � � z N � w z � ¢ � � U a ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 � � �- _ — —� 0 0 —�- P' ' �� ; 41 WALL MOUTED SERVICE SWK SHEET TITLE � �! 42 VINYL STORE LOGO AND HOURS o�-o° ; , � i ; � ; � � ; : ; � ; . , � i . , ' o�-o�� I NTERIOR B.O. FIN. FLR. B.O. FIN. FLR. 43 11X17 CHALKBOARD SIGN s2 FRP-01 WB-01 44 OUR SANDWICHES SIGN ELEVATIONS 45 ORDER HERE FINGER � 46 SOLID SURFACE COUNTER TOP AND TOP CAP. 03 ELEVATION AT FRONT SERVICE LINE WALL — INTERIOR ^ ELEVATION AT HALLWAY 47 GLASSTILEONFACEOFCHIPCUBBIEBASE. � , SCALE: 3/8"=1'-0" O`� SCALE: 3/8"=1'-0" O TYPICAL OF (3) SIDES. 0 � SHEET NUMBER A4.3 � 0 s � c � KEY NOTES 1O ELECTRICAL PANELS OCOAT RACKS. 3O MANAGERS DESK. REFER TO DETAIL 12/A5.1 FOR ADDITIONAL INFO. 4O PROVIDE BLOCKWG IN WALL 5O MOP BASIN. REFER TO PLUMBING DRAWINGS. 7z 6O PREP TABLE. REFER TO PLUMBING DRAWINGS FRP-01 AS.� 6'-0" BLOCKING 4 FRP-01 � FRP-01 �a �o �2 10'-6° ------- B.O. CEILING I \I 10�-6" O7 WALL MOUNTED HAND SINK. REFER TO _ B.O. CEILING PLUMBWG DRAWINGS. . . � ' � � � . ��'��, � � . . . � I m - I O8 3-COMP. SINK. REFER TO PLUMBWG DR,4WWGS. I ; � � ') O SOAP DISPENSER I � - I � li I ;) � � � � m � s� � �_ i � J cY� i, 1`I �� 10 SHELVWG ON CASTERS i � ,000 m , � r I' �❑ � � e� I \� � 1 PAPER TOWEL DISPENSER W-- m� � u zo u �i � WALKW _ � i M ( - — � , i � � COOLER I 12 WALK-IN COOLER/FREEZER � V � i . � _ _�- �_I� � �( I� r � � i 13 STAINLESS STEEL CORNER GUARD � �--I I i � �� � I I B.O. FIN. FLR. � � k ._ -- �_ ___ '' � ' I � 0'-0° 14 BAGN-BOX. REFER TO DETAIL 111A5.0 _ i B.O. FIN. FLR. 18 10 16 5 13 3: WB-�� IWB-�� WB-01 15 NOT USED. 16 LOCATION OF CHEMICAL DISPENSER. 17 NOT USED. ELEVATION AT PREP ROOM 02 ELEVATION AT PREP ROOM ,8 WATERHEATER. O � SCALE: 3/8 =1 -0 O SCALE: 3/8"=1'-0" �z FRP-01 10'-6" 10'-6" B.O. CEILING 4 B.O. CEILING z 6'-11" 7'-2 3/4" 3'-0 4" BLOCKING BLOCKING OC NG � ----- ------- ; �------- -� �------ � � � ; � I I - z I� �? �� Z I I`� I Ir, v \ ��,.� O I I' � � N m � � ---- ----- - � � m �----- ------J � _ � .. . . CV � _ '_. _ '_' __. __ .J � _ V . . — _ � � ° — — � . . . � . . . _ a— CV V (V . . � . . O� / O . . . . �1i � � Lf� . C'7 � d' . M � � . / / (O OI o11 i � , � � i I , / i � I . . OI�OII . � i . � � � B.O. FIN. FLR. B.O. FIN. FLR. WB-01 �4 WB-01 s �� � s �s a �a 03 ELEV. AT PREP ROOM ^ ELEV. AT PREP ROOM SCALE: 3/8"=1'-0" O`� SCALE: 3/8"=1'-0" f �� �� e �. i „ 222 MERCHANDISE MART PLA7A, SUITE 2300 CHICAGQ IL 60654 P: 312.951.0600 F:312.951.0300 NMNV.POTBELLY.COM � /��_ GPD GROUP, WC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fa�c: 330.572.2102 W � � Q U � � z O � H � � � � � J � Z � � � rn N � r � M � Z J w � � Q U M � � � 0 � 0 N � w m � � Z � U W O � a SHEET TITLE INTERIOR ELEVATIONS SHEET NUMBER A4.4 0 � _ 5 � � s � WOOD CAP W313 5/8" GYP BD ON 3 � 5/8" METAL STUD CHAIR RAIL W305 DOOR CASING � ��- GC TO PAINT PT-04 �� W300 FRAMING A5A WOOD ROSETTE � � / 3 5/8" METAL STUD MILLWORK CAP " • R � W316 sia^ WOOD APRON �� BEADBOARD OR WALL, TYP. PARTIAL HGT. WALL 73/ � 10 � � W309 10 PLYWOOD PANELS AS � i W LK-IN NOTED ON INTERIOR I� - - - - - - - - - - - " - � A5.0 i � WOOD TRIM � � � � C OLER � ELEVATIONS "' I / � � 5'-z° i W313 QUEUING _� \ DOORFLANGE / LINE � W304 OR W317 � � � i DOOR CASING � � � J � 5'33l4° i W/ BACK BAND TILE JAMB WITH � a �\ / i � Q a I W � R.o. � � W300 W319 SEALANT AT SIDES, � Y ¢ a �-� I �_ Y � o OPEN FOR � I � W � NOT GROUT (TILE TO o p � e �� I I c� o� � ( � Z REACH-W 15 o Z M Z MATCH TILE BEHIND ; v� °O �"' Q� I I � a' � �� � � �' Z COOLER I � A5.0 � o � LL SERVICE LINE) °-�� I a � a= �-� � � � I o � � I " � o DOOR CASING o � �� � a � i � COOLER APRON � � � W/ BACK BAND � � I �� �� I PACKAGE � BEYOND � � � i � I W320 W300 W319 � � � � i� � � � � � � � L _ _ _ _ _ _ _ _ _ _ _ � y I � � � � 2X8 CEDAR CAP 2X8 CEDAR CAP WOOD BASE � 5`0�� I (1" OVERHAN�) (1" OVERHANG) LINE OF WOOD CUT ( � HOLD � I WB04 PATTERN AT CAP, TYP. I � � � W315 ' W315 SILICONE BEAD AT � - COOLER APRON � PERIMETER (CLEAR) EDGE OF CEDAR TOP o� 73/4�1 0� �- o W320 0 CAP � p Q= � ALIGN WITH B.O. PACKAGE 0o CEDAR CAP NOT USED BEADBOARD WAINSCOT END COND. LOW WALL ^ COOLER OPENING - SECTION ELEVATION SEA�ANT O� SCALE: 3" = 1'-0° O� SCALE: 1 1/2" = 1'-0" O� SCALE: 3" = 1'-0" O`�' SCALE: 3/4" = 1'-0" O � CEDAR TOP CAP W315 GC TO STAIN ST-06 2�� WOOD CAP W313 12° X 12" CEDAR TOP CAP, SIMILAR TO W315 GC TO STAIN ST-06 �" M���' � � � � � � � � � � �� �� ' � � � ' DOOR CASING � � � � � � � � � 3i4" PLYWOOD PANELS W317 �� � ON OUTSIDE FACE - BOTH SOIDES �' �-- 1" CLEAR BETWEEN GYP W300 � 3/4" PLYWOOD PANELS W317 GC TO STAW ST-06 � BD AND COOLER WALL � �' �� �� � � � OVER METAL STUDS ON � I I � 3 5/8" METAL STUD WITH 2" X 2" ��' WALK-IN � QUEUWG - � OUTSIDE FACE - BOTH SIDES � I I STEEL PIPE W/ 3/4" SQ WELDED °,i PREFAB COOLER WALLS COOLER �t LINE ' � � � � � � � � � GC TO STAIN ST-06. a I I � BASE PLATE W/ 3l8" X 3" � � �' � / FROM VENDOR — " � � � � � � o � _ o I I CONCRETE WEDGE FASTENERS � � � �� � ,� v � � � WOOD APRON � � � � � I (WALL TYPE $) � � � �� / � W309 0 0 � � GYP BD / METAL STUD o WOOD CORNER TRIM W301 o I I WALL � � �� 3/4" SQ WELDED WOOD ROSETTE � AT ALL (4) EDGES � � I I GC TO PAINT PT-04 I I I I BASE PLATE W/ 3/8" I I � � X 3" CONCRETE STAINLESS STEEL W316 WOOD BASE WB04 I I I I WEDGE FASTENERS CLOSURE STRIPS � ATTACHED TO COOLER � SILICONE BEAD AT � I I � � �. WALL ONLY FROM � Z �w WOOD TRIM (2X2 CUT TO SIZE) PERIMETER (CLEAR) � I I � SILICONE BEAD AT VENDOR � g W313 PERIMETER(CLEAR) O — TILE JAMB \ � _ ,, � � WOOD BASE WB04 --- 06 NOT USED 07 SECTION END CONDITON SECTION LOW WALL CLOSURE DETAIL COOLER HEAD O SCALE: O SCALE: 1" = 1'-0" OH SCALE: 1" = 1'-0" O9 SCALE: 3" = 1'-0., � O SCALE: 3" = 1'-0�. O O � POPLAR TOP CAP � W302 COOLER PREFABRICATED COOLER QUEUING - i CONT. SEALANT (BOTH SIDES TYP.) LINE BOO�R CASING W/ BAC QUARTER ROUND TRIM � 3ia° : - W300 W319 W306 ,. : 2 1/2" QUARRY TILE BASE 114" MIN. � : "'` QUARRY TILE FLOORWG ON THINSET -0� ; � a l \� - CEDAR TONGUE & GROUT OVER WATERPROOF GYP BD WALL FGROOVE PLANKS W303 _ MEMBRANE o SMOOTH FACE OUTGC TO TILE JAMB 0 o STAIN CEDAR ST-06 � � � _ � WALK-IN � EXISTING CONCRETE SLAB COOLER a 0 NOTE: IF NOT SLAB ON GRADE, WOOD BASE COOLER WILL BE PROVIDED WITH WB04 INTEGRAL FLOORING. NO QUARRY NOTE: ALL DISSIMILAR MATERIALS SILICONE BEAD AT TILE FLOOR OR BASE INSIDE COOLER TO HAVE FLEXIBLE GROUT PERIMETER (CLEAR) WHEN NOT SLAB ON GRADE 11 NOT USED 12 CEDAR PANELING NOT USED ^ C04LER BASE COOLER JAMB SCALE SCALE: 1 1/2" = 1'-0" �� SCALE: 1 1/2" = 1'-0" �`� SCALE: 1 1(2" = 1'-0" � 5 SCALE: 3" = 1'-0" �o�i r--: ► ,s, '; 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, Il. 6�654 P: 312.951.0600 F:312.951.0300 NNJvV.POTBELLY.COM � /��_ GPD GROUP, tNC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax:33�.572.2102 O O W H C/) W � U � z O d' z W � U � � � 0 � 0 N � W m � � z U w 0 � a 40���� a7 45 �j `g��dmJ ,a� .�. _.� C m,e m �� � :. a � a � . � �° r � ,.� aai z t`� ^. `` i .e � �s r3 ; t f f��'' -;r o SHEET TITLE INTERIOR DETAILS SHEET NUMBER A5.0 h � � 0 01 NOT USED NOT USED NOT USED SCALE:1"=1'-0" O� SCALE:1/2"=1'-0" O� SCALE:#####�#� COMPRESSOR ALLOW ADEQUATE � N SPACE & VENTILATION , FOR TOP MOUNT COMPRESSOR. GC TO PROVIDE ACCESS FOR SERVICE. DOORFRAME �_\ TILE BAND W/ SEALANT, NOT GROUT � C9 � � � . Z �o . . . . . . � o a � � °O � � , 5/8" FLANGE "' � � "' 1/4" TILE TO BOX � � 5/8" GYP BD TO BOX � I .. � [V N p � . � . . . _ � � , o � � � � G NOT USED SECTION AT COOLER NOT USED Ov SCALE: 1"=1'-0" O� SCALE: 1/2" = 1'-0" O� SCALE: 3/4"=1'-0" O 6'-0" BLOCKING NOTE: REFER 3'-6" TO DETAIL 1'-9" 1'-9" 7/E7.0 FOR _ _ POWER & DATA 7'-9" F,"T`""��� RECEPTACLE � 6 PROVIDE � , � � LOCATIONS BLOCKWG �� 5/8° FLANGE IN WALL � �� �;�Pz ADJUSTABLE A5.1 DOOR FRAME COOLER WALL °° _ _ _ _ sf� � SHELF LOCKABLE `��. .. � ON WALL GC BUILT WALL CABINET �— ,� - STANDARDS I i ( `_� .a� �H _ il I: II � VOLUME � h C rEft CONTROLS � � � t� i � i {; � � �, c,4 G.0 TO INSTALL Z 5/8" DRYWALL TO BOX 1(4" TILE TO BOX -- Y_ i � ;i � II `� � 5 2 DOOR FLANGE S I STALLED OOR � �� o� � ��� �� � T-STATS CEDAR TOP CAP - m rn i �� ,';� �� I [ o� 11'-10" 5'-3 3/4" o M i �` L J , PHONE � ; _ REFER TO CONSTRUCT N PLAN ROUGH OPENING �5AND1RFICH SHOPT� 222 MERCHANDISE MART PLAZA, SUIFE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 NNWV.POTBELLY.COM � /�i_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.21W Fax: 330.572.2102 O O � W �-- � C/� 0 Q � � J J � Z L^L I..L � LC'� r � ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 �� 0 WALL � o m �` � o� � PRii�ie#2 � . . Eau�PMENr � _ �� - — � � ,EIBo FOR SHEET TITLE RACK ; , FUTURE INTERIOR 'I_ _ _ �- �� I - - — — - � � � - DESK TOP MON�TOR 2-3 � DETAILS ARM `� I m� I- F,r � r, ON WALL N M I f, E I[, °�,"ET � BRACKETS N I I � I -I �---� � i� �—� SHEET NUMBER M W � 0 � 0 N � W m � � z U w O � a � ELEV AT MANAGER DESK NOT USED PLAN AT COOLER n 12 „ �., 13 14 A5 � � SCALE: 1/2 = 1-0 SCALE: ###t#�i### SCALE: 1/2" = 1'-0�� ■ � c e CEILING TILE TO RETURN 8'-6° A.F.F. VERTICALLY TO TOP OF B.O. GYP. CLG. COOLER SUSPENDED ACT CEILWG � 3 A N' I± lAt 3(: !i � N 47 i' tr� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P:312.951.0600 F:312.951.0300 10'-6" A.F.F WWW.POTBELLY.COM WOOD APRON T.O. FIN. FLOOR W309 1/4" SHIM SPACE ' _ Z � 7'-0" A.F.F. HALLWAY DINING ¢ � � �� � � � � � B.O. HEADER - ���i/� � � , � �/ � � � � � � � ' � WALK-IN � � WOOD CASING , / ' �COOLER W308 � ,, / �� j �� '; "�� / ,� � � � � � � � WALL BEYOND � � % � 5° I 01 NOT USED NOT US�D HEAQER AT T.R. VESTIBULE A SOFFIT AT COOLER DETAIL NOT USED SCALE: 1/2"=1'-0" O� SCALE: NTS O� SCALE: 3"=1'-0" O`� SCALE: 1" = 1'-0" 05 SCALE: PROVIDE SECONDARY UNISTRUT FRAMWG TO EXISTING ROOF STRUCTURE PROVIDE SECONDARY (AS REQUIRED) UNISTRUT FRAMWG TO EXISTWG ROOF STRUCTURE RIGID CONDUIT FROM CEILWG (AS REQUIRED) TO J-BOX 6" 20 GUAGE METAL — RIGID CONDUIT FROM CEILWG STUDS @16" O.C. WI ALL THREAD HARDWARE TO GC TO ATTACH CHAIN TO TO J-BOX 1/2" GYP. BD EACH SIDE STABILIZE TRACK FIXTURE TO UNISTRUT UNISTRUT AND TRACK SPACED AS REQUIRED ALONG TRACK � LENGTH � ,-- 1/2" GYP. BD B.O. J-BOX � 0 12'-9"A.F.F�SEE NOTE 1o'-0"A.F.F. B.O. J-BOX CUSTOM MARKETING SIG 8.0. CLG. A.F.F. TO SLIDE IN TO FRAME J-BOX J-BOX LIGHT FIXTURE AS SCHEDULED TRACK END FEED LIGHT FIXTURE AS _ 8'-0" A.F.F. NOTE: SCHEDULED 8.0. SIGN J-BOX AT 11'-6" A.F.F.: WTERIOR DECORATIVE FIXTURES (L100, L101, L102, 12'-0" A.F.FSSEE NOTE L107, L108) B.O. FIXTURE J-BOXAT 16'-1" A.F.F.: FIX7URE L109 G NOT USED TRACK FIXTURE MOUNTING Q MARKETING HANGING SIGN LIGHT FIXT MOUNTING VESTIBULE SOFFIT CEILING OV SCALE: 1/2"=1'-0° 07 SCALE: 1-1/2"=1'-0" oU SCALE: N.T.S. O� SCALE: 1 1/2"=1'-0" � O SCALE: 3"=1'-0" 0 0 PROVIDE SECONDARY 12" SPIRAL DUCT 3 5/8" STUD SOFFIT WALL AT 16" UNISTRUT FRAMWG O.C. TIED BACK TO DECK, TYP. TO EXISTING ROOF STRUCTURE PT24 � (AS REQUIRED) PROVIDE DIAG METAL STUD — -- PROVIDE SECONDARY RE-INFORCMENT FROM B.O. SOFFIT \� BACK TO STRUCTURE, TYP. � RIGID CONDUIT FROM CEILWG UNISTRUT FRAMWG � PT22 TO EXISTING ROOF STRUCTURE GYP BD UP TO B.O. CEILING ---- �� � TO J-BOX (AS REQUIRED). EC TO PROVIDE STRUCTURE � X� � BRACING AT STRUCTURE � WOOD TRIM CAP � x � ALL THREAD HARDWARE TO � ST-04 W313 � x STABILIZE TRACK FIXTURE TO X RIGID CONDUIT FROM CEILING � UNISTRUT AND TRACK SPACED PT2g TO J-BOX AS REQUIRED ALONG TRACK EC TO PROVIDE BALL JOINT AT 1ENGTH i : , J-BOX � � � � � � � METAL PANELS IN � � .���� J-BOX SUSPENDED GRID 0 13'-9" A.F.F�SEE NOTE PT23 � B.O. J-BOX „ SUSPENDED GRID — 0 0 ,� \, 12-0 A.F.F. (DECK �� J-BOX T.O. J-BOX SYSTEM :� � - PT21 TYR i � TRACK END FEED NOTE: 10'-0" A.F.F_ ; , , LIGHT FIXTURE AS PROPELLER & NOSE . gOTTOM OF LOWEST PORTION OF SWIVEL PLATE -- SCHEDULED pT24 DUCT TO BE AT 10'-0" AFF. CEILING FAN EXTENSION ROD B•0. BULKHEAD 5 ��p�� � �� • PAINT FINISH TO BE SEMI-GLOSS FRT WOOD BLOCKING WOOD APRON 13-0 A.F.FISEE NOTE AS SCHEDULED • GRAPHIC STICKERS TO BE B.O. FIXTURE PROVIDED BY OWNER AND 1X6 (BEYOND) W309 ST-04 �� ST-04 W309 INSTALLED BY GC I � 1 NOT USED TRACK FIXTURE MOUNTING 13 SUBMARINE FINISH DETAIL 14 CEILING FAN MOUNTING CEILING TRIM DETAIL SCALE: 1/2"=1'-0" �� SCALE: 1 1(2 = 1-0 SCALE: NTS SCALE: 3"=1'-0" � 5 SCALE: 3"=1'-0" ' ��� /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Faz:330.572.2102 J G Q U Z M \L z W � U ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 6>�°e`�. �' '���dA°��� s� � aea ,� t�F� - �� � , 6; ;� e,� � ��� '��v�. ry : � :. `. � ti�t � ., � �: SHEET TITLE INTERIOR DETAILS SHEET NUMBER A5.2 M � � 0 � 0 N � W m � _ z U w 0 � a � 0 � C � SERVICE DINING DINING RESTROOM BLACK BORDER TILE FT04 CAFE DOOR WHERE OCCURS _ MARBLE THRESHOLD QUARRY TILE-SET MOSAIC TILE � J � IN THIN SET � MORTAR BED � 1/4"MAX. 6" � 1/4" MAX. . . . . . . . � lT �, i i i ) ,1 � � . ' � �n i� . � . . . . �)� ( ( :.,, .� 1 � ; JA t I,� . Q � , � � . 1 �,; BULLNOSE TILE � � - 1$" � N , � �["� t � [z I (t, _ � � � .. lT '' i TJ � � 7 i,f . � � � � � � . � �"�7 T 1 f A t I : � i l � � � . � � � . . . . . 1 i ( 1 . l t [ - . .� .� . I,.0 J l i� S i �T.�� 1 I� � � e .........:... � . � . . . 1 . 7 - 7 C L 1.'. _ - . � � - . . � h � ��, r � �r a � �, �� � � �� a � _ � � - - _ � , t: z , t�:_. � �,� �� � . ,� s tzir x� ' � �� �� ` _ _ - , r `" �. . . . .. . . .. . . . . . ��r ' ` `'I"i � 1� tr7 ; � � . � � . .' , ., _. .. � � . � � ,- � � - � �a �� f :. 1 7 � `� , 1 �i �7�',� _ ;. ' , _ ` . . . . . � � (��� r i ,C :�) �C � I ( � 1 �t• ��t', . . \� WATERPROOFING . . . . . . . I,7 rt ( i j_11 I I ' i � I . � . . . .. . � �a `��= `�_ .7� � 7 � �� �� MEMBRANE � � �� ��� � CONCRETE THINSET TO BE 1/8 X 1/8 SLAB TAPERED @ LAST SCORWG �(WHERE APPLICABLE) TIME COURSE PER PLAN WHITE TILE ��"��� EXISTING FT03 CONCRETE SLAB SCORING PER PLAN- REFER TO FWISH PLAN 01 NOT USED 02 ENLARGED MOSAIC DETAIL TRANSITION DETAIL A NOT USED MARBLE THRESHOLD SCALE: SCALE: 3"=1'-0" O� SCALE: 3"=1'-0" O`�' SCALE: 3"=1'-0" O� SCALE: 3" = 1'-0" – WOOD OR METAL STUD WALL BEYOND DINING EXTERIOR � CERAMICTILE -REFERTO ENTRY VEST. EXTERIOR PREP DINING � FINISH SCHEDULE MOISTURE RESISTANT GYPSUM � � � � � � � � BOARD FROM 6" TO CEILING FULL SADDLE ANODIZED PREP DOOR FULL SADDLE ANODIZED BRONZE THRESHOLD SET WHERE OCCURS BRONZE THRESHOLD SET CONTINUOUS SEALANT Y � 5/8" DUROCK 6" HIGH IN CONT. SEALANT BED 8Y � W CONT. SEALANT BED BY DOOR- SEE _ � � ) G.C.- REFER TO FLOOR DOOR- SEE G.C.- REFER TO FLOOR SCHEDULE � � ` -� �— CONTINUOUS WATERPROOFWG FINISH PLAN SHEET SCHEDULE QUARRY TILE-SET FINISH PLAN SHEET WEATHER o � ;� 6" UP WALL IN THIN SET WEATHER - MORTAR BED BACKER ROD & SEAL STRIPPWG INTEGRAL QUARRY TILE COVE HELIX WALK OFF MAT BY STRIPPING –' � � BASE W/ BULLNOSE EDGE GRAND ENTRANCE a � �� � BULLNOSE TILE 118" �� � QUARRY TILE FLOORWG BACKER ROD & SEAL `� M�. � � � � ¢ 6,. � � , , ' � � CONC. SCORING �, Q � � _ <. � � � �' � , �- N � . � ' , ., ._ �� .:; . . _�. . . . � . � " _ `. . � . � _ . � � � �- � � � � WATERPROOFING THROUGHOUT PREP AREA, SERVICE LINE CONCRETE THINSET TO BE SEALED CONCRETE EXISTING EXISTWG BACK WALL AND AT KITCHEN AT NON-SLAB ON GRADE EXISTWG EXISTWG SLAB TAPERED @ LAST FLOORING CONCRETE FOUNDATION CONDITIONS ONLY-APPLY TO FACE OF DUROCK 6" HIGH (TYP.) CONGRETE FOUNDATION TIME COURSE SLAB NOTE: RUN WATERPROOFING TO TOP OF DUROCK . REFER TO FLOOR PLANS SLAB FOR LOCATIONS. WATERPROOFING TO BE OF CONTINUOUS APPLICATION W! NOTE: PROVIDE ANODIZED BRONZE THRESHOLD FLOOR WATERPROOFING FOR TOTAL WATERPROOF SEAL. NOTE: PROVIDE ANODIZED BRONZE THRESHOLD 06 TRANSITION DETAIL NOT USED Q TRANSITION DETAIL: TRANSITION DETAIL QUARRY TILE COVE BASE O SCALE: 3" =1'-0" 07 SCALE: 3"=1'-0" oU SCALE: 3"=1'-0" O� SCALE: 3"=1'-0" � Q SCALE: 3"=1'-0.� 0 WOOD OR METAL STUD WALL BEYOND �- WOOD OR METAL STUD WALL FRP - REFER TO FINISH SCHEDULE BEYOND (END 2" FROM THE FLOOR) /-- CERAMIC TILE - REFER TO ' FINISH SCHEDULE HELIX WALK OFF MAT BY �' MOISTURE RESISTANT GYPSUM GRAND ENTRANCE BOARD FROM 6" TO CEILING � MOISTURE RESISTANT GYPSUM BOARD FROM 6" TO CEILING CONTINUOUS SEALANT � CONTINUOUS SEALANT TAPERED ALUMINUM o o � 5/8" DUROCK (6" HIGH) � / �= 5/8" DUROCK (6" HIGH) - � CONTINUOUS WATERPROOFING o o � FRAME BLACK FINISH �_ � _� � � CONTINUOUS WATERPROOFWG 0 6 UP WALL T o j 6" UP WALL � — INTEGRAL QUARRY TILE COVE BULLNOSE CERAMIC TILE COVE BASE W/ BULLNOSE EDGE BASE � QUARRY TILE FLOORING � CERAMIC TILE & GROUT BED a �..' . . . N � . � � f� ' . � -� , ' .- /� EXISTING . . CONCRETE WATERPROOFING THROUGHOUT PREP AREA, SERVICE LINE WATERPROOFING THROUGHOUT TOILET ROOM AT SLAB BACK WALL AND AT KITCHEN AT NON-SLAB ON GR,4DE NON-SLAB ON GRADE CONDITIONS ONLY- APPLY TO CONDITIONS ONLY-APPLY TO FACE OF DUROCK 6" HIGH (TYP.) FACE OF DUROCK 6" HIGH (TYP.) NOTE: RUN WATERPROOFING TO TOP OF DUROCK . REFER TO FLOOR PLANS SURFACE MOUNTED TAPERED ALUMINUM FRAME FOR LOCATIONS. WATERPROOFING TO BE OF CONTINUOUS APPLICATION W/ NOTE: RUN WATERPROOFWG TO TOP OF DUROGK . REFER TO fL00R PLANS CONTACT LOCAL IMPACT SPECIALTIES FOR MORE JNFORMATION. FLOOR WATERPROOFING FOR TOTAL WATERPROOF SEAL. FOR LOCATIONS. WATERPROOFING TO BE OF CONTINUOUS APPLICATION W/ FLOOR WATERPROOFWG FOR TOTAL WATERPROOF SEAL. 11 WALK OFF MAT _ 12 NOT USED NOT USED TILE COVE BASE �a FRP CERAMIC TILE COVE BASE . SCALE: 3- 1-0 SCALE: 3" = 1'-0" SCALE: 3"=1'-0" � 4 SCALE: 3"=1'-0" � 5 SCALE: 3"=1'-0" 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 W�MN.POTBELLY.COM � /��_ GPD GROUP,INC. 520 South Main Street, Suite 2531 Akron, OH 49311 330.572.2100 Fax: 330.572.2102 O O � W H � C/� Q � J N J M � O � J (� �p °° w d- o Z �' � � Z W U C!) W � � � � � N � w � � Q o Z � � � U a ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 &�4�� � � pee�A�� Qa "me°� ,,�'` �� ��'�e�'o �; :> ` ` '` 4 � t i i � � f, e ;in ,sAo � a E; ` . � s � # � � SHEET TITLE INTERIOR DETAILS SHEET NUMBER A5.3 3 q a 0 s w � � � � C e SOLID SURFACE ALL SUBSTRATE BEHIND GOUNTERTOP CN03 (BY 9 ��2�� PANEL REVEALS TO BE RETAIL, INSTALL GC) � � PAINTED BLACK BY G.C. �. CHIP CUBBIE BOLT TO SOLID SURFACE TOP CAP ` BLOCKWG (BY PSW, 3-5/8" METAL STUD @ 16" O.C. CN-03 (BY RETAIL, INSTALLED INSTALLED BY GC) WITH 1/2" PLYWOOD AND �N BY GC) BOLTED TO BLOCKING 1 1/2" WOOD BLOCKING, TYP. 3�-0° FRP ON SERVICE SIDE (BY FROM UNDERNEATH FRP UP BACK OF CHIP GC) � vz^ O CUBBIE ALL SUBSTRATE BEHIND PANEL REVEALS TO BE WOOD BLOCKING, TYP. (2) 3 5/8" METAL STUD @ 16" O.C. CERAMIC TILE WT-11 PAWTEQ BLACK BY G.C. WITH �" PLYWOODIFRP ON (PROVIDED AND , s v2° . 3-5/8" METAL STUD @ 16" O.C. SERVICE SIDE (BY GC) INSTALED BY GC) �' CLEAT ATTACHMENT (BY 3�4 2" DIA. PIPE LEG BY RETAIL, � � WITH 1/2" PLYWOOD AND FRP RETAIL, INSTALLED BY GC) � � � ON SERVICE SIDE (BY GC) � ON �" PLYWOOD SUBSTR,4TE, INSTALL 6Y GC) SEE FLOOR Z PLAN FOR LOCATION �� � 3i (2) LAYERS z" PLYWOOD 5" STRIP (BY GG} � o � 4 CLEAT ATTACHMENT (BY — 1 HAT CHANNEL (BY GC) ON 1 HAT CHANNEL (BY � RETAIL, INSTALLED BY GC) �� 1' X 1' ACCESS PANEL (BY GC) GC) 1-1/2° WOOD PANEL W/ WALL ;�, � O N Z° P L Y W O O D S U B S T R A T E, � CLEATS (BY RETAIL, 5" STRIP (BY GC) ` INSTALLED BY GC) `� �o° (2) LAYERS 2" PLYWOOD ON 1" � �` � z" CEMENT BOARD WITH 04 HAT CHANNEL (BY GC) WITH " STAWLES$ STEEL TILE 2 CEMENT BOARD WITH O � __- QUARRY TILE BASE � - � � CORNER FINISH TR9M, �" CERAMIC TILE BASE WB-06 CERAMIC TILE WT-11 9i16° CERAMIC TILE BASE WB-06 O (BY GC) � SCHLUTER ECK-K (16 ) (BY GC) � z CEMENT BOARD WITH OR EQUAL (BY GC) QUARRY TILE BASE (BY GC) CERAMIC TILE BASE WB-06 t v2" 43/4^ (BY GC) CERAMIC TILE WT-11 STAWLESS STEEL TILE EDGE (PROVIDED AND 3ia" 43/4^ FINISH TRIM, SCHLUTER INSTALED BY GC) � �" RONDEC OR EQUAL (BY GC) 01 ADA COUNTER/POS COUNTER ORDER/LOAD STATION CHIP CUBBIE CHIP CUBBIE CORNER DTL O SCALE: 1" = 1'-0" O� SCALE: 1"=1'-0" O� SCALE: 1"=1'-0" �4 SCALE: 3"=1'-0�� O O ALL SUBSTRATE BEHIND s v2° PANEL REVEALS TO BE PAINTED BLACK BY G.C. N SOLID SURFACE TOP CAP CN-03 (BY RETAIL, INSTALLED ��� BY GC) BOLTED TO BLOCKING � ��2�� , FROM UNDERNEATH 1 1/2" WOOD BLOCKING, TYP. � � 3-5/8" METAL STUD @ 16" O:C. WITH 1/2" PLYWOOD AND FRP � ON SERVICE SIDE (BY GC) R cn `o � �' a`CLEATATTACHMENT(BY �. RETAIL, INSTALLED BY GG) �= ON 2° PLYWOOD SUBSTRATE, 5" STRIP (BY GC) " 2° CEMENT BOARD WITH OCERAMIC TILE BASE WB-O6 � (BY GC} " QUARRY TILE BASE (BY GC) 3!4 4 3/4" 7" O05 ORDERiLOAD STATION SGALE: 1 "=1'-0" �, �t� x--r � 1 F . � , 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P:312.951.0600 F:312.951.0300 VNMN POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Streey Suite 2531 � Akron, OH 44311 330.572.2100 Faz: 330.572.2102 J W � � U � z M � � Z J � Q U M � � 0 � 0 N � w m � � z E- U W 0 � a � SHEET TITLE INTERIOR DETAILS SHEET NUMBER A5.4 3 � ¢ 0 0 w =Q W N _ � a C e SPECIFICATIONS DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS BIDDING INSTRUCTIONS 61-01 PROPOSALS A) PROPOSALS ON COMPLETE WORK ON EACH DIVISION AS DESCRIBED IN FOLLOWING SPECIFICATIONS; W SUCH SUBSEQUENT ADDENDA AS MAY BE ISSUED DURING PERIOD OF BIDDING, AND SHONM W ACCOMPANYING DRAWINGS WILL BE RECEIVED AT THE TIME AND PLACE AS DIRECTED BY POTBELLY HEREINAFTER REFERRED TO AS POTBELLY REPRESENTATNE. B) BASE PROPOSALS ON MATERIALS AND METHODS DESCRIBED IN SPECIFICATIONS, INCLUDE ALL LOCAL, STATE AND FEDERAL TAXES IN BID. QUOTE ALL ALTERNATES AND UNIT PRICES LISTED, FOR WHICH PRICE SHALL BE TOTAL COST TO 04VNER INCLUDING ALL OVERHEAD AND PROFIL C) LIST SUBCONTRACTORS, MATERIAL SUPPLIERS AND MANUFACTURERS IN SPACES PROVIDED ON FORM OF PROPOSAL. 81-02 STANDARDS A) ARTICLES, DEVICES, MATERIALS, PORMS OF CONSTRUCTION, PIXTURES, ETC., NAMED W SPECIFICATIONS TO DENOTE KIND AND QUALITY DESIRED ARE "STANDARDS". BASE ALL PROPOSALS ON SAME. B) ANY MAKE OP MATERIALS AND APPARATUS SPECIFIED ACCEPTABLE TO OWNER, UNLESS OTHERWISE STATED. BASE BID ON ANY MAKE SPECIFIED, CONTRQCTOR NOT REQUIRED TO STATE SELECTION OF SPECIFIED MAKE UNTIL AFTER AWARD OF CONTRACT, EXCEPT THOSE REQUIRED LISTED ON BID DATE ON FORM OF PROPOSAL. C) CONTRACTORS SHALL BID PROJECT USING STANDARDS SPECIFIED. SUCCESSFUL BIDDER SHALL MAKE WRITfEN APPLICATION FOR APPROVAL OF OTHER MATERIAL OR APPARATUS WHEN SPECIFICATIONS REFER TO °OR APPROVED," ETC. BIDDER DESIRING TO PROPOSE SUBSTITUTIONS MAY DO SO W ACCORDANCE WITN ARTICLE B1-03 AND SECTION 016000. B1-03. FINAL APPROVAL OF SUCH PROPOSALS WILL BE THE POTBELLY DIRECTOR OF CONSTRUCTION. B1-03 SUBSTITUTIONS A) IT IS NOT THE INTENT OF SPECIFICATIONS TO EXCLUDE USE OF MERITORIOUS PRODUCTS OF EQUAL VALUE. EXCEPT WHERE PRODUCTS ARE SPECIFIED "NO SUBSTITUTION," BIDDERS ARE WVITED TO SUBMIT SUBSTITUTIONS WITH THEIR BIDS OF OTHER MAKES OF MATERIAL AND APPARATUS FORARCHITECTAND OWNER CONSIDERATION. B) IF BIDDER PROPOSES SUBSTITUTIONS OF MATERIALS, FIXTURES, ARTICLES, DEVICES, METHODS OF CONSTRUCTION, ARRANGEMENT OF COMPONENTS, OR OTHER ITEMS DIFFERENT FROM THOSE CALLED FOR BY DRAWINGS AND SPECIFICATIONS, BID PRICE FOR SUBSTITUTIONS MUST INCLUDE ALL GOSTS INVOLVED. INCLUDING ANY AND ALL COSTS FOR WORK REQUIRED BY OTHER CONTRACTORS OR SUBCONTRACTORS NECESSITATED BY PROPOSED SUBSTITUTION,ORCHANGE. BIDDERSDESIRINGCONSIDERATIONFORTHE USE OF MATERIALS, EQUIPMENT, ETC., NOT W SPECIFICATIONS MAY SUBMIT PROPOSALS FOR SUBSTITUTIONS OF SAME FOR STANDARDS AS SPECIFIED, USING °SUBSTITUTION FORM" ATTACHED TO FORM OF PROPOSAL LISTWG. FOR EACH PROPOSED CHANGE (1) "STANDARD" SPECIFIED, (2) SUBSTITUTION, AND (3) CHANGE IN BID PRICE, (OR"NO CHANGE"). FURNISH OWNER COMPLETE SPECIFICATIONS AND DESCRIPTION OF PROPOSED SUBSTITUTION CONSIDERED FOR ACCEPTANCE, UPON REQUEST. C) SUBSTITUTIONS ACCEPTED MUST BE WCORPORATED IN FORMAL CONTRACT. NO SUBSTITUTIONS ALLOWED SUBSEQUENT TO AWARD OF CONTRACT. SUBSTITUTIONS WILL NOT AFFECT DETERMINATION OF LOWEST BID. D) IF BIDDER NAMES NO SUBSTITUTE ON HIS "SUBSTITUTION SHEET", "STANDARDS" SPECIFIED SHALL BE USED. OWNER RESERVES RIGHT70 ACCEPT ANY ALTERNATE, OR SUBSTITUTION BID PROVIDED SUCH ACTION TAKEN IN SUFFICIENT TIME NOT TO DELAY PROGRESS OF WORK, OR INCUR ADDITIONAL EXPENSE TO CONTRACTOR. 81-04 ADDENDA: LIST ADDENDA ISSUED DURING BIDDING PERIOD ON FORM OF PROPOSAL, AND IN CLOSING CONTRACT, THEY SHALL BECOME A PART THEREOF. BIDDER IS RESPONSIBLE FOR TRANSMITTING ADDENDA INFORMATION TO ALL CONCERNED WITN HIS BID. ACKNOWLEDGE RECEIPT OF ADDENDA IN SPACE PROVIDED, ON FORM OF PROPOSAL. 81-05 PROPOSAL FORMS (BID FORMS) A} SUBMIT PROPOSAL ON FORM PROVIDED, FULLY COMPLETING ALL BLANK SPACES IN FORM; STATE TOTAL BOTH IN WRITING AND IN FIGURES; SIGNATURE SHALL BE IN LONGHAND AND COMPLETED FORM SHALL BE WITHOUT INTERLINEATION, ALTERATION, OR ERASURE. SUBMIT PROPOSALS IN DUPLICATE, MARKED ON OUTSIDE OF ENVELOPE WITH TITLE OF WORK AND NAME OF BIDDER. OBTAIN PROPOSAL FORMS FROM POTBELLY REPRESENTATIVE ANO MAIL, OR DELIVER BID PER HIS INSTRUCTIONS. B) ALL BIDDERS ARE CAUTIONED TO ALLOW AMPLE TIME FOR TR4NSMITTAL OF BIDS. BID RECEIVED AFTER SPECIFIED TIME WILL NOT BE ACCEPTED OR RECOGNIZED. THE TIME OF RECEIPT WILL DETERMINE THE ACCEPTABILITY OF MAILED BIDS, REGARDLESS OF POSTMARK C) ANY BID MAY BE WITHDR4WN PRIOR TO THE TIME SCHEDULED ABOVE FOR THE OPENING OF BIDS OR AUTHORIZED POSTPONEMENT THEREOF. NO BID MAY BE WITHDRAWN FOR THIRTY (30) DAYS, SATURDAYS, SUNDAYS, AND LEGAL HOLIDAYS EXCLUDED AFTER OPENWG OF GENERAL BIDS. N0 TELEPHONE OR TELEGR4PHIC BID, CHANGE IN BID OR WITHDRAWAL BID WILL BE RECEIVED OR RECOGNIZED. D) TELEFAX BIDS MAY BE RECEIVED AT OWNER'S OPTION. B1-O6 EXAMINATION OF PREMISES: PRIOR TO SUBMITTING PROPOSAL, BIDDER WILL EXAMWE PREMISES AND SATISFY HIMSELF AS TO CONDITIONS UNDER WHICH HE SHALL BE OBLIGED TO OPERATE IN PERFORMING WORK, OR THOSE CONDITIONS WHICH AFFECT HIS WORK. BIDDERS VISIT AND EXAMINE SITE TO INFORM THEMSELVES OF SITE CHARACTERISTICS AND CIRCUMSTANCES AFFECTWG COST OF WORK AND TIME REQUIRED FOR EXECUTION OF CONTRACT. BIDDERS WHOLLY RESPONSIBLE FOR ERRORS AFFECTING COST OF WORK AND TIME REQUIRED FOR EXECUTION, AS WELL AS ERRORS WHICH MAY OCCUR IN THEIR PROPOSAL DUE TO FAILURE TO MAKE SUCH VISITS AND EXAMINATIONS. 81-07 EXAMINATION OF DOCUMENTS: BIDDERS EXAMINE ALL CONTRACT DOCUMENTS, INCLUDWG ALL DRAWINGS AND SPECIFICATIONS FOR ALL DIVISIONS OF WORK AS WELL AS HIS ONM, NOTING PARTICULARLY ALL REQUIREMENTS WHICH AFFECT HIS WORK IN ANYWAY. PAILURE OF BIDDER TO ACQUAINT HIMSELF WITH QUANTITYAND CHARACTEROF WORK REQUIRED TO COMPLETE HIS DIVISION OF CONTRACT W CONPORMITY WITH ALL REQUIREMENTS FOR PROJECT WILL NOT BE CONSIDERED AS BASIS FOR EXTRA COMPENSATION. Bt-08 1NQUIRIES: SHOULD BIDDER FIND DISCREPANCIES OR OMISSIONS IN DRAWINGS OR SPECIFICATIONS, OR HAVE DOUBT OF THEIR MEANING, NOTIFY ARCHITECT OR POTBELLY REPRESENTATIVE AT ONCE. ARCHITECT WILL ISSUE WRITTEN INSTRUCTIONS TO ALL BIDDERS REGARDING SAME. NEITHER ARCHITECT, NOR POTBELLY REPRESENTATIVE WILL BE RESPONSIBLE FOR ANY ORAL INSTRUCTIONS. INQUIRIESJN REGARD TO BID SHALL BE MADE MINIMUM OF ONE (1) WEEK PRIOR T0 BID RECEIPT DATE. B1-�9 CONTRACTAWARD: OWNERWILLCONSIDERCOMPETENCYAND RESPONSIBILITY OF BIDDERS AND SUBCANTRACTORS IN MAKING AWARD. OVvNER IS NOT OBLIGATED FOR COST INCURRED BY BIDDER IN PREPARING BID. OWNER IS NOT OBLIGATED TO ACCEPT LOWEST BID, OR ANY BID. 81-10 CONTRACT DOCUMENTS WILL BE MADE AVAILABLE FOR REPRODUCTION AND USE VIA THE POTBELLY FTP SITE. B1-11 EXAMINATION OF SITE A) THE CONTRACTOR SHALL EXAMINE THE SITE,-0RAWINGS, SPECIFICATIONS, AND CONTRACT FORM FOR THE WORK PRIORTO SUBMITfING PROPOSAL AND FULLY INFORM HIMSELF OF THE CONDITIONS UNDER WHICH THE WORK MUST BE COMPLETED AND ASSUME RESPONSIBILITY FORANY UNUSUAL AND UNFORESEEN DIFFICULTIES TO BE OVERCOME IN COMPLETING THE WORK. B) THE CONTRACTORAND ALL SUBCONTRACTORS MUST VERIFY DIMENSIONS AND MEASUREMENTS OF ANY EXISTING CONDITIONS PRIOR TO ORDERING MATERIALS OR DOING WORK THAT REQUIRES COORDINATION WITH OTHER TRADES OR EXISTING CONDITIONS. NO CLAIM BASED ON DIFFERENCE SETWEEN ACTUAL DIMENSIONS AND THOSE SHOWN ON DRAWINGS WILL BE CONSIDERED. 61-12 BOND: BIDDER TO WHOM CONTRACT IS AWARDED SHALL QUAIIFY TO EXECUTE, AND SHALL EXECUTE A PERFORMANCE BOND AND LABOR AND MATERIAL PAYMENT BOND FOR 100%OF AMOUNT OF CONTRACT, IF DIRECTED BY OWNER. BOND PREMIUMS PAID BY OWNER. FORM UTILIZED SHALL BE CURRENT EDITION OF AIA FORM A-31 t. EXECUTE AND DELIVER BOND TO OWNER WITHIN FIFTEEN (15) DAYS AFTER SIGNING CONTR4CT, IP BOND DEEMED NECESSARY. 61-13 SUBCONTRACTORS, SUPPLIERS, MATERIALS AND EQUIPMENT: LIST NAME, IN PLACES PROVIDED ON PROPOSAL FORM, ALL SUBCONTRACTORS, SUPPLIERS, MATERIALS AND EQUIPMENT REQUESTED ON WHOM OR WHICH BID IS BASED AND WHOM BIDDER INTENDS TO EMPLOY OR WHICH HE WTENDS TO USE. COMPLETE ALL SPACES IN FORM OF PROPOSAL. SEE SUPPLEMENTARY GENERAL CONDITIONS, ARTICLE 28. Bt-14 BIDDING PROCEDURE A) SUBMIT BIDS USING APPROVED PROPOSAL FORMS, COPIES ARE AVAILABLE FROM POTBELLY REPRESENTATIVE. COMBINED PROPOSAL IS INVITED ON ENTIRE CONTRACT INCLUDING GENERAL CONTRACT, PLUMBING, HEATING, AIR CONDITIONING AND VENTILATING, AND ELECTRICAL. SUBMIT AS ONE TOTAL CONTR4CT AMOUNT IN SPACE PROVIDED ON FORM OF PROPOSAL. SUBMIT PROPOSAL ON OWNER SUPPLIED "FORM OF PROPOSAL" UNDER THIS FORM, CONTRqCT AMOUNT IF FIXED AND CONTRACTOR GUARANTEES A LIMIT OF CONSTRUCTION COST. B) BIDS BY INVITATION ONLY. OWNER RESERVES RIGHT TO REJECT ANY, OR ALL BIDS. C) BIDDERS AND THEIR PROPOSED SUBCONTRACTORS COMPETENCY AND RESPONSIBILITY WILL BE GONSIDERED IN MAKING AWARD. B1-15 UTILITY COMPANIES REGULATIONS COMPLY WITH REGULATIONS OF LOCAL UTILITY COMPANIES PRIORTO SUBMISSION OF PROPOSAL. DETERMINE FROM EACH UTILITY COMPANY SUPPLYING SERVICE TO PROJECT ALL REQUIREMENTS AND INCLUDE COST OF SAME IN BID COST OF RELOCATION OF UTILITIES SERVICE LINES INTERFERING WITH CONSTRUCTION SNALL BE INCLUDED W CONTRACTOR'S PROPOSAL 61-16 CODES AND RESTRICTIONS THIS BUILDING DESIGN IS BASED UPON LOCAL BUILDING CODES. SHOULD PROVISIONS OF PREVAILING LOCAL BUILDING AUTHORITIES OR CODES GOVERNING AREA FOR CONSTRUCTION OF THIS BUILDWG DIFFER FROM THOSE PROVISIONS OF THE LOCAL CODE, IT WILL BE THE RESPONSIBILITY OF BIDDER TO ADVISE ARCHITECT IMMEDIATELY OF SAME AND T0 BID PROJECT ACCORDING TO GOVERNING CODES. AN ADDENDUM WILL BE ISSUED INSTRUCTING ALL BIDDERS. CONTRACTFORMS DIVISIONB-CONSTRUCTIONCONTRACTFORM: FURNISHEDBYTHEGENERAL CONTRACTOR. UNLESS OTHERWISE AGREEABLE TO THE OWNER, USE AIA 107 - AGREEMENT BETWEEN OWNER AND CONTRACTOR FORA PROJECT OF LIMITED SCOPE, MODIFIED TO INCORPOR4TE THE GENERAL AND SUPPLEMENTARY CONDITIONS HEREIN.. PERFORMANCE BOND: PERFORMANCE AND MATERIALS BOND SHALL BE EXECUTED ON AMERICAN INSTITUTE OF ARCHITECTS PERPORMANCEBOND. A.I.A. DOCUMENT NUMBER 311, CURRENT EDITION. THIS FORM IS AVAILABLE FOR WSPECTION IN ARCHITECT'S OFFICE AND IS NOT BOUND WITHIN THIS SET OF SPECIFICATIONS. BOND SHALL BE IN THE AMOUNT OF 100%OF CONTRACT; BOND TO BE PAID BY OWNER, IF REQUIRED. GENERAL CONDITIONS DIVISION C - GENER4L CONDITIONS GENERAL CONDITIONS OF CONTRACT FOR CONSTRUCTION - CONSTRUCTION MANAGER AS ADVISOR, AS PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS, AIA DOCUMENT NUMBER A-232, 20�9 EDITION, SHALL APPLY TO GENERAL CONTRACT AS WELL AS ALL SUBCONTRACTS, EXCEPT AS SAID GENERAL CONDITIONS MAY BE ABROGATED, AMPLIFIED, MODIFIED, OR NULLIFIED BY SUPPLEMENTARY GENER4L CONDITIONS, CONTAINED IN THESE SPECIFICATIONS, SAID GENERAL GONDITIONS AND SAID SUPPLEMENTARY GENERAL CONDITIONS HAVE BEEN CAREFULLY READ AND CONSIDERED PART OF THE SPEqFICATIONS. SUPPLEMENTARY GENERAL CONDITIONS ARTICLE 1- DRAWINGS AND SPECIFICATIONS A) CONTRACTOR PROVIDES ALL ITEMS, ARTICLES, MATERIALS, OPERATIONS OR METHODS INDICATED ON PLANS, SECTIONS AND/OR DETAILS, INCLUDING ALL LABOR, MATERIALS, EQUIPMENT AND INCIDENTALS REQUIRED OR NECESSARY FOR THEIR COMPLETION. Bj CALL ERRORS OR INCONSISTENCIES IN DRAWINGS OR SPECIFICATIONS TO THE ATTENTION OF THE ARCHITECT OR POTBELLY REPRESENTATIVE FOR PROPER ADJUSTMENL DO NOT PROCEED WITH WORK IN CASES OF UNCERTAINTY. C) CONTRACTORAGREES THAT WORK HEREIN DESCRIBED SHALL BE COMPLETE IN EVERY DETAIL, EVEN THOUGH EVERY ITEM NECESSARILY INVOLVED IS NOT PARTICULARLY MENTIONED. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS NECESSARY FOR COMPLETION OF WORK DESCRIBED IN CONTRACT DOCUMENTS, AND NOT AVAIL HIMSELF OF ANY MANIFESTLY UNINTENTIONAL ERROR OR OMISSION SHOULD SUCH EXIST. D) SHOULD CONTRACT DOCUMENTS DISAGREE AS TO QUALITY OR QUANTITY OF WORK, PROVIDE BETTER QUALITY OR GREATER QUANTITY UNLESS INSTRUCTED OTHERWISE BYARCHITECT W WRITING. E) CERTAIN SPECIFICATIONS AND CERTAIN OF OTHER CONTRACT DOCUMENTS, INCLUDING THESE GENERAL CONDITIONS, ARE OF SIMPLIFIED TYPE AND INCLUDE INCOMPLETE SENTENCES. OMISSION OF WORDS OR PHR4SES, SUCH AS "THE CONTRACTOR SHALL" '9N CONFORMITY THEREWITH", "SHALL BE", "AS NOTED", "A", "AN", "THERE", AND °ALL" ARE INTENTIONAL. OMITTED WORDS SHAlL BE SUPPLIEDINFERENCE IN SAME MANNER AS THEY ARE WHEN A NOTE OCCURS ON DR4WINGS, WORDS "SHALL BE" OR "SHALL BE SUPPLIED" BY INFERENCE PARTICULARLY WHEN A COLON OR HYPHEN IS USED WITHIN SENTENCE OR PHRASES. F) WORD "PROVIDE° SHALL BE UNDERSTOOD TO MEAN "FURNISN" INSTALL AND (IF APPLICABLE) PLACE IN OPER4TION° UNLESS OTHERWISE STATED. WORDS "DIRECTED", "SELECTED", °APPROVED", "REQUIRED", "PERMITTED", "ACCEPTED", SHALI BE UNDERSTOOD TO MEAN DIRECTION, SELECTION, APPROVAL, REQUIREMENTS OR PERMISSION, RESPECTIVELY OF THE OWNER'S DIRECTOR OF CONSTRUCTION„ UNLESS OTHERWISE STATED. G) SPECIFICATIONS ARE ARRANGED IN SECTIONS, BUT SUCH SEGREGATION SHALL NOT BE CONSIDERED AS LIMITING WORK REQUIRED BY ANY TRADE. DIVISION OF WORK SHALL BE THE RESPONSIBILITY OF CONTR4CTOR. H) DRAWWGS AND SPECIFICATIONS ARE COMPLEMENTARY. EXCEPT AS FOLLOWS, WHAT IS CALLED FOR BY ONE SHALL BE CONSIDERED AS CALLED FOR BY BOTH. 1) WHERE FINISHES NOT INDICATED ON THE DRAWING FINISH PLANS, ELEVATIONS, OR NOTES ARE INDICATED IN THE FINISH LEGEND, SUCH FINISHES SHALL NOT BE REQUIRED. 2) WHERE HARDWARE NOT REFERENCED ON THE DOOR SCHEDULE IS INDICATED IN HARDWARE GROUP SCHEDULE, SUCH HARDWARE SHALLNOT BE REQUIRED. 3) ALL MATERIALS, PROCEDURES, AND COMPLIANCE REQUIREMENTS REASONABLY NECESSARY FOR CONSTRUCTION OF A COMPLETE AND FUNCTIONING FACILITY IN ACCORDANCE WITH DESIGN INTENT SHALL BE REQUIRED, REGARDLESS OF EXTENT OF DOCUMENTATION. ARTICLE 2 - DEFINITIONS: NOTICES: CONTRACT DOCUMENTS A) OWNER-CONTR4CTOR AGREEMENT. B) GENERALCONDITIONS: C) SUPPLEMENTARY GENERAL CONDITIONS: (IN SPECIFICATIONS, OF WHICH THIS IS A PART.j D) GENERAL SPECIFICATIONS. E) DRAWIN�S AND ISSUED ADDENDA. OWNER WHERE REFERENCED IN THE SPECIFICATIONS, THE "OWNER" OR "OWNER'S REPRESENTATIVE" SHALL MEAN °THE OWNER'S DIRECTOR OF CONSTRUCTION," AS DESIGNATED IN THE EXECUTED OWNER-CONTRACTOR AGREEMENT. POTBELLY SANDWICH SHOP 222 MERCHANDISE MART PLAZA 23RD FLOOR CHICAGQ ILLINOIS 60654 312.951.O6W ARCHITECT AS NAMED ON COVER SHEET CONTRACTOR AS NAMED IN CONSTRUCTION CONTR4CT, UNLESS OTHERWISE DEFINED, SUCH AS GENERAL CONTRACTOR OR ELECTRICAL CONTRACTOR, TERM CONTRACTOR SHALL BE UNDERSTOOD TO MEAN ANY CONTRACTOR OR CONTRACTORS WHO HAVE ENTERED INTO SEPARATE CONTRACT WITH OWNER. GENERALCONTRACTOR AS NAMED IN CONSTRUCTION CONTRACT. CONTRACTOR FOR ALL OF WORK EXCEPT TNOSE PARTS FOR NMICH OWNER HAS CONTRACTED SEPARATELY. ADDENDUM LETTER OR FORM CLARIFYING, AMENDING, OR INTERPRETING CONTRACT DOCUMENTS ISSUED BEFORE RECEIPT OF BIDS. REQUEST FOR QUOTATION LETTER OR FORM ISSUED AFTER AWARD OF CONTRACT REQUESTING CHANGE OR AMENDMENT OF CONTRACT DOCUMENTS. CHANGE ORDER IS ISSUED, FROM THIS INFORMATION. CNANGE ORDER LETTER OR FORM AUTNORIZING CHANGES IN THE CONTRACT DOCUMENTS EXECUTED PER THE GENERAL CONDITIONS. FIELD ORDER LETTER OR FORM AUTHORIZING CHANGES WHICH DO NOT CHANGE THE CONTRACTAMOUNL WORK ALL THAT WHICH SHALL BE DONE, PER ARTICLE 1 OF GENERAL CONDITIONS. ARTICLE 3 - ABBREVIATIONS REFERENCE TO TECHNICAL SOCIETY'S ORGANIZATION BODIES OR DOCUMENTS IS MADE IN SPECIFICATIONS IN ACCORDANCE WITH FOLLOWING ABBREVIATIONS: AIA AMERICAN INSTITUTE OF ARCHITECTS ACI AMERICAN CONCRETE INSTITUTE AIEE AMERICAN INSTITUTE OF ELECTRICAL ENGINEERS AHJ AUTNORITYHAVINGJURISDICTION AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION ASA AMERICAN STANDARDS ASSOCIATION ASLA AMERICAN SOGETY OF LANDSCAPE ARCHITECTS ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS ASTM AMERICAN SOCIETY FOR TESTIN� AND MATERIAIS AWI ARCHITECTURAL WOODWORK INSTITUTE AWSC AMERICAN WELDWG SOCIETY CODE FS FEDERAL SPECIFICATIONS ICC INTERNATIONAL CODE COUNCIL NAAMM NATIONALASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS NFPA NATIONAL FIRE PROTECTION ASSOCIATION NBS NATIONALBUREAU OFSTANDARDS NEC NATIONAL EIECTRICAL CODE SJI STEELJOISTINSTITUTE SPR SIMPLIFIED PRACTICE RECOMMENDATION UL UNDERWRITER'S LABORATORIES, INC. BOCA BUILDWGOFFICIALSCODEASSOCIATION UBC UNIFORM BUILDING CODE SBCCI STANDARD BUILDING CODE CONGRESS INTERNATIONAL ARTICLE 4- CODES AND STANDARDS MATERIAL SUPPLIERS SUBMIT EVIDENCE, IF REQUESTED, MATERIAL IN QUESTION COMPLIES WITH APPLICABLE CURRENT CODES AND STANDARDS AS REFERRED TO IN SPECIFICATIONS. ARTICLE 5- DAMAGE RESULTING FROM WORK A) GENERAL CONTRACTOR/CONTRACTOR IS SOLELY RESPONSIBLE FOR EXPENSES INCURRED OR DAMAGE CAUSED BY DEFECTIVE OR ILLTIMED WORK PERFORMED OR WHICH HE FAILS TO PERFORM PER HIS CONTRACT. B) CONTRACTOR LIABLE AND RESPONSIBLE FOR MAKING, AT HIS OWN EXPENSE, ANY AND ALL REPAIRS REQUIRED BY REASON OF DAMAGE RESULTING FROM PERFORMANCE, NON-PERFORMANCE OR IMPROPER PERFORMANCE OF WORK PROVIDED; HOWEVER, THAT CONTRACTOR SHALL NOT REPAIR ANY DAMAGE DIRECTLY CAUSED SOLEIY BY ACTS OF OWNER. IF REPAIRS ARE NOT PROMPTLY MADE, OWNER MAY MAKE REPAIRS AND DEDUCT COSTS FROM AMOUNTS OTHERWISE DUE TO CONTRACTOR AT THAT TIME OR BILL CONTRACTOR FOR SAID COSTS. C) CONTRACTOR TAKE WHATEVER PRECAUTIONS ARE NECESSARY TO PROTECT PREMISES BELONGING TO OWNER COMPRISING OR BEING IN VICINITY THEREOF, SO AS TO SAFEGUARD ALL STRUCTURES, FIXTURES, FURNISHINGS AND EQUIPMENT LOCATED THEREON. PROTECT ALL ADJACENT PROPERTY AND PROPERTY IN VICINITY FROM DAMAGE. HOLD OWNER HARMLESS FROM ANY DAMAGES. ARTICLE 6 - CANTR4CTOR'S RESPONSIBILITY CONTRACTOR AGREES TO INDEMNIFY OWNER AGAINST ANY AND ALL CLAIMS, LOSS, DAMAGE, COSTS AND EXPENSE ARISING FROM INJURY TO OR DEATH OF PERSONS OR DAMAGE TO PROPERTY AND EMPLOYEES OF OWNER, OCCURRING, WHOLLY OR IN PART, AS RESULT OF WORK DONE OR OMITTED, OR CONTRACTED TO BE DONE; BUT, NOT DONE BY CONTR4CTOR OR HIS SUBCONTRACTORS, IF ANY, OR EMPLOYEES OR AGENTS OR INVITEES OF CONTRACTORORANY SUBCONTRACTORS, REGARDLESS OF WHETHERANY SUCH INJURY TO OR DEATH OF PERSONS OR DAMAGE TO OR DESTRUCTION OF PROPERTY IS DUE OR CLAIMED TO BE DUE, IN WHOLE OR IN PART, TO ANY NEGLIGENCE OR FAULT OF OWNER OR HIS EMPLOYEES, AGENTS OR INVITEES, EXCEPT CLAIMS, LOSS, DAMAGE, COSTS OR EXPENSE RESULTING SOLELY FROM THE WILIFUL ACTION OF OWNER. CONTRACTOR SHALL BEAR ALL LOSSES OCCURRING BY REASON OF THEFT OR LOSS, OR DAMAGE, REGARDLESS OF CAUSE, T0: A) ALL MATERIALS, SUPPLIES, EQUIPMENT AND APPARATUS OWNED, USED OR FURNISHED, REGARDLESS OF WHETHER OF NOT SAID MATERIALS, SUPPLIES, EQUIPMENT OR APPARATUS ARE INCLUDED IN ITEMS TO BE FURNISHED OR USED HEREUNDER OR TO BE INCORPORATED IN WORK, PRIOR TO WORK'S COMPLETIONS. B) ALL OF CONTRACTOR'S TOOLS, MACHINERY, EQUIPMENT, MATERIALS, SUPPLIES, APPLIANCE, SHORING, SCAFFOLDING, FALSE WORK AND SNED AND PERSONAL PROPERTY OF CONTRACTOR'S EMPLOYEES. OWNER NOT RESPONSIBLE IN ANY MANNER FOR THE PROPERTY OF CONTRACTOR, CONTRACTOR'S EMPLOYEES, OR SUBCONTRACTORS OR SUBCONTRACTOR'SEMPLOYEES. ARTICLE 7- PAYMENTS BY CONTRACTOR CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS REQUIRED FOR WORK AND SHALL PAY FORALL FEES, TAXES, ROYALTIES, RENTS, PENALTIES AND CHARGES AS MAY BE REQUIRED FOR WORK EXCEPT AS HEREINAFTER SPECIFICAILY PROVIDED. OWNER RESERVES RIGHT TO TAKE OUT ANY, OR ALL PERMITS. THESE PAYMENTS SHALL BE IN ADDITION TO ANY PAYMENTS TO OWNER UNDER ANY TERMS, CONDITION, OR PROVISION OF CONTRACT DOCUMENTS. OWNER WILL PAY ALL REAL ESTATE ASSESSMENTS AND REAL ESTATE TAXES. SIGN PERMIT SHALL BE OBTAINED BY SIGN CONTRACTOR AT HIS EXPENSE. ARTICLE 8 - SPECIAL WSPECTIONS SPECIAL INSPECTIONS REQUIRED UNDER PROVISIONS OF BUILDING CODE OR UTILITY COMPANY REGULATIONS ARRANGED AND PAID POR BY CONTRACTOR. ARTICLE 9 - MEASUREMENTS BEFORE ANY MATERIAL IS FABRICATED, CONTRACTOR AND EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY MEASUREMENTS AND LAY OUT WORK INCLUDED IN HIS CONTRACT, AND SHALL BE RESPONSIBLE FOR PROPER FITTWG AND ACCURACY. ARTICLE 10 - MATERIALS PLACE ORDERS FOR MATERIALS AND EQUIPMENT TO BE EMPLOYED IN WORK; OTHER THAN THOSE DESIGNATED FURNISHED BY OWNER, AS SOON AS POSSBLE AFTERAWARD OF CONTRACT. CONTRACTOR SHALL KEEP OWNER, ARCHITECT, AND POTBELLY REPRESENTATIVE INFORMED AS TO AVAILABILITY OF ALL SPECIFIED MATERIALS AND EQUIPMENT, ADVISE THEM PROMPTLY IN WRITING OF ALL ORDERS PLACED, AND OF SUCH MATERIALS AND EQUIPMENT AS MAY NOT BE OBTAINABLE FOR PURPOSES OF CONTRACT, WHETHER DUE TO CONDITIONS OF MARKET OR OTHER LIMITING AND GOVERNING FACTORS. ARTICLE 11- WARRANTY OF TITLE NO MATERIALS, SUPPLIES, OR EQUIPMENT INCORPORATED IN WORK SHALL BE PURCHASED SUBJECT TO ANY CHATTEL MORTGAGE OR UNDER A CONDITIONAL SALE OR OTHER AGREEMENT BY WHICH AN INTEREST THEREIN, OR IN ANY PART THEREOF, IS RETAtNED BY SELLER, SUPPLIER, OR MANUFACTURER. ARTICLE 12 - MOVING OF MATERIALS IF IT BECOMES NECESSARY DURING PROGRESS OF WORK TO MOVE MATERIALS WHICH ENTER INTO CONSTRUCTION, OR EQUIPMENT TEMPORARILY PLACED, CONTRACTOR FURNISHING SAME SHALL, WHEN DIRECTED BY POTBELLY, MOVE THEM WITHOUT COST TO OWNER. ARTICLE 13- WORKMEN AND WORKMANSHIP A) CONTRACTOR MAINTAIN ORDERAND DISCIPLINEAMONG WORKMEN AT ALL TIMES. B) WORKMANSHIP: ONLYARTISANSANDMECHANICSQUALIFIEDTHROUGH EXPERIENCE IN THEIR RESPECTIVE BRANCNES SHALL EXECUTE OR PERFORM WORK. ARCHITECT, OR POTBELLY REPRESENTATIVE IS NOT ON JOB SITE AT ALL TIMES; HOWEVER, WORK INSTALLED CONTRARY TO CONTRACT DOCUMENTS SHALL BE REMOVED AND REPLACED WITHOUT DELAY, IN CONFORMITY WITH CONTRACT DOCUMENTS WHEN DIRECTED BY ARCHITECT, OR POTBELLY REPRESENTATIVE WITHOUT ADDITIONAL COST TO ONMER. C) WORKMEN NOT COMPLYING WITH PROVISIONS OF CONTRACT DOCUMENTS SHALL BE IMMEDIATELY REMOVED BY CONTRACTOR FROM ANY PREMISES BELONGWG TO OWNER UPON NOTICE OF ARCHITECT OR POTBELLY REPRESENTATNE. ARTICLE 14- PROSECUTION OF WORK IT IS DUTY OF CONTRACTOR TO NOTIFY VARIOUS SUBCONTRACTORS 4VHEN THEIR PRESENCE IS REQUIRED, EXPEDITE FLOW OF MATERIALS AND SECURE NECESSARY INSPECTIONS. CONTRACTOR SHALL REQUIRE THAT ALL SUBCONTRACTORS HAVE COMPETENT SUPERVISOR ON SITE WHENEVER HIS WORKIS BEING PERFORMED. CONTRACTOR SHALL GIVE REASONABLE NOTICE TO ARCHITECT AND POTBELLY REPRESENTATIVE WHEN HIS PRESENCE IS REQUIRED FOR SPECIAL CONSULTATIONS, EXAMINATIONS, OR DECISIONS. ARTICLE 15 - EXAMINATION BEFORE STARTING AND INTERMITTENTLY AS WORK PROGRESSES, CONTRACTOR AND SUBCONTRACTORS EXAMINE WORK INSTALIED BY OTHERS INSOFAR AS IT APPLIES TO HIS WORK AND PROMPTLY NOTIFY ARCHITECT OR POTBELLY REPRESENTATIVE IF CONDITIONS EXIST THAT PREVENT HIM GIVING SATISFACTORY RESULTS. ARTICLE 16 - PROTECTION OF MATERIALS A) PROTECT PRE FINISHED MATERIALS OR MATERIALS FINISHED IN PLACE WHEN INSTALLED BEFORE COMPLETION OF WORK FROM DAMAGE UNTIL ACCEPTANCE OF PROJECT. REPLACE MATERIALS DAMAGED BEFORE OR AFTER INSTALLATION WITH NEWAND UNDAMAGED FINISHED MATERIALS. REFINISH, OR REPLACE AND FINISH, MATERIALS AFTER INSTALLATION WHICH ARE DAMAGED AS DIRECTED. ADDITIONAL CHARGES ARE NOT HONORED BY ONMER FOR REPLACEMENT OR REPAIR OF DAMAGED MATERIALS. B) PROVIDE SECURITY AND FACILITIES TO PROTECT WORK, AND EXISTING FACILITIES, AND OWNER'S OPERATIONS FROM UNAUTHORIZED ENTRY, VANDALISM, OR THEFL ARTICLE 17 - NO WAIVER BY OWNER FAILURE OF OWNER IN ONE OR MORE INSTANCES TO INSIST UPON STRICT PERFORMANCE OF ANY TERMS OF CONTRACT OR TO EXERCISE ANY OPTION HEREW CONFERRED, SHALL NOT BE CONSTRUED AS WANER OR RELINQUISHMENT TO ANY EXTENT OF RIGHT TO ASSERT OR RELY UPON ANY SUCH TERMS OR OPTION ON ANY FUTURE OCCASION. ARTICLE 18 - SUSPENSION OF WORK IF WHOLE OR PART OF WORK IS SUSPENDED CONTRACTOR SHALL, AT HIS OWN EXPENSE, COVER, SECURE AND PROTECT ALL PARTS OF HIS WORK THAT MIGHT BE INJURED FROM ANY CAUSE. ARTICLE 19 - STOPPAGE OF WORK IN EVENT OWNER IS PERMANENTLY ENJOINED OR OTHERWISE STOPPED FROM COMPLETING THIS CONTRACT, OWNER IS LIABLE TO CONTRACTOR FOR ONLY WORK ACTUALLY PERFORMED AND MATERIALS AT SITE LESS SALVAGE VALUE THEREOF. SCHEDULE OF VALUES OF CONTRACT SUBMITTED AT TIME CONTRACT IS SIGNED WILL BE USED AS A BASIS OF SETTLEMENT. ARTICLE 20 - CLEANING UP A) EACH CANTRACTOR, UPON COMPLETION OF HIS WORK, COLLECT AND REMOVE ALL RUBBISH, SURPLUS MATERIALS, TOOLS, AND SCAFFOLDING. KEEP PREMISES NEAT AND ORDERLY BY PERIODIC REMOVAL AND CLEANUP. REMOVE CRATES AND CARTONS IN WHICH MATERIALS, EQUIPMENT OR FIXTURES ARE RECEIVED DAILY. B) IF, IN OPINION OFARCHITECT, POTBELLY REPRESENTATIVE, OR GENERAL CONTRACTOR, NEATNESS IS NOT MAINTAINED, POTBELLY REPRESENTATIVE OR GENER4L CONTRACTOR MAY HAVE AREA CLEANED AND CHARGE COSTS TO RESPONSIBLE CONTRACTORS. Cj AT COMPLETION OF BUILDING OR ANY PART THEREOF, GENERAL CONTRACTOR, IN ADDITION TO REMOVAL OF ACCUMUL4TED RUBBISH, SHALL REPLACE ANY BROKEN GLASS, REMOVE STAINS, SPOTS AND MARKS FROM FINISH WORKAND HARDWARE. D) REMOVE ALL STICKERS AND LEAVE BUILDWG IN A CLEAN CONDITION. ARTICLE 21 - GUARANTEE UNLESS OTNERWISE SPECIFIED, CONTRACTOR GUARANTEES ALL MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE OF BUILDING, AND SHALL REPLACE OR SATISFACTORILY REPAIR, WITHOUT COST TO OWNER OR INTERFERENCE WITH ONMER'S OPERATION, ANY DEFECTIVE WORKMANSHIP OR MATERIALS. ADDITIONAL REPLACEMENTS OR REPAIRS, WITHOUT LIMITATION, SHALL BE MADE BY CONTRACTOR WITHOUT COST TO OWNER UNTIL ALL DEFECTIVE WORKMANSHIP OR MATERIALS HAVE BEEN CORRECTED AND THE WORK COMPLETED IN ACCORDANCE WITH CONTRACT DOCUMENTS EVEN IF THE ONE (1) YEAR PERIOD ABOVE SPEGFIED HAS EXPIRED IF OWNER HAS GIVEN CONTRACTOR NOTICE OR ORIGINAL FAILURE OF COMPLIANCE WITH CONTRACT DOCUMENTS IS PRIOR TO EXPIRATION OF SAID PERIOD. ARTICLE 22 - JOB MEETINGS 1. PRECONSTRUCTION MEETING: THE OUVNER WILL ADMINISTER PRECONSTRUCTION MEETING FOR EXECUTION OF THE OWNER-CONTRACTOR AGREEMENT (IF NOT PREVIOUSLY COMPLETED) AND EXCHANGE OF PRELIMINARY SUBMITTALS. AGENDA SHALL INCLUDE THE FOLLOWING. A. IDENTIFICATION AND INTRODUCTION OF OWNER, ARCHITECT, DIRECTOR OF CONSTRUCTION, CONTRACTOR, PRINCIPLE SUBCONTRACTORS, LANDLORD, AND OTHER KEY PERSONNEL B. CLARIFICATION RESPONSIBILITIES IN USE OF SITE. C. PROJECT SCHEDULE, INCLUDING SCHEDULE FOR CRITICAL SUBMITTALS, RESUBMITTALS, PAY APPLICATIONS, TESTING AND INSPECTIONS, AND PROGRESS MEETINGS. D. QUALITYASSURANCE. E. SUBMITTAL REQUIREMENTS, INCLUDING FORMP,T, RECIPIENTS, REVIEW PROCESSES,ANDTURNAROUND. F. MOCK-UPS: SCHEDULE, TYPE, LOCATION, APPROVAL CRITERIA, AND REMOVAL. G. TARGETS AND VERIFICATION OF SUSTAINABLE CONSTRUCTION MATERIALS AND PRACTICES. H. TIMING, NOTIFICATION, SUBMITTAL REQUIREMENTS, HANDLING, AND COORDINATION OF ONJNER FURNISHED ITEMS. I. COMMUNICATION AND RECORDKEEPING. 2. GENERAL CONTRACTOR SCHEDULE SEMIMONTHLY PROGRESS MEETING BETWEEN HIMSELF, SEPARATE CONTRACTORS, AND MAJOR SUBCONTRACTORS. NOTIFY POTBELLY REPRESENTATIVE OF TIME OF MEETING WHICH SHALL BE SAME HOUR AND DAY OF WEEK FOR DURATION OF WORK. GENERAL CONTRACTOR MUST TAKE AND DISTRIBUTE MINUTES OF ALL MEETINGS, TO SUBCONTRACTORS, SEPARATE CONTR4CTORS AND POTBELLY REPRESENTATIVE. ARTICLE 23 - MATERIALS AND SUBCONTRACTORS CONTRACTOR EMPLOY SUBCONTRACTORS AND FURNISH MP,TERIALS NAMED IN PROPOSAL, IF APPROVED BY OWNER. ARTICLE 24- SCOPE OF AGREEMENT EXECUTION OF ABOVE MENTIONED OWNER-CONTRACTOR AGREEMENT, BOTH ONMERAND CONTRACTOR AGREE TO BE BOUND BY EACH AND EVERY TERM AND CONDITION OF AFORESAID CONTRACT DOCUMENTS. ARTICLE 25- MECHANICAL EQUIPMENT MANUALS CONTRACTOR DELIVER TO OWNER WITHIN ONE WEEK OF COMPLETION OF WORK, OPERATION AND MAINTENANCE MANUALS PERTAINING TO ALL MECHANICAL EQUIPMENT FURNISHED AND/OR INSTALLED UNDER CONTRACT. FAILURE TO FURNISH SUCH MANUALS WITHIN ALLOTTED TIME LIMIT WILL CAUSE SAID CONTRACTOR TO BE LIABLE FOR DAMAGES RESULTING FROM MISUSE OF SAID EQUIPMENT. ARTICLE 26 - NOTICES CONTR4CTOR SEND WRITTEN NOTICES INDICATING NATURE AND SCOPE OF WORK TO ALL PROPERTY OWNERS IN VICINITY OF WORK WHOSE PROPERTY MIGHT IN ANYWAY BE AFFECTED BY WORK UNDER THIS CONTRACT. ARTICLE27-SUBCONTRACTORS LIST OF SUBCONTRACTORS REFERRED TO UNDER ARTICLE 5.2.1 OF GENERAL CONDITIONS OF CONTRACT SHALL WCLUDE EACH SUBCONTR4CTOR'S ADDRESS AND TELEPHONE NUMBER. ARTICLE 28 - INSURANCE REQUIREMENT IN ADDITION TO THOSE CALLED FOR IN GENERAL CONDITIONS A) GENERAL: THESE REQUIREMENTS ARE INCLUDED IN THE BID DOCUMENTS. ARTICLE 29 - INSPECTWG AND TESTING LABORATORY SERVICES A) OWNER WILL APPOINT, EMPLOY, AND PAY FOR SPECIFIED SERVICES OF AN INDEPENDENT FIRM TO PERFORM INSPECTING AND TESTING THAT IS SPECIFIED AS OWNER'S RESPONSIBILITIES. THE CONTRACTOR WILL APPOINT, EMPLOY AND PAY FOR SPECIFIED SERVICES OF AN INDEPENDENT FIRM TO PERFORM INSPECTION AND TESTING THAT IS SPECIFIED AS CONTRACTOR'S RESPONSIBILITY. B) THE INDEPENDENT FIRM WILL PERFORM INSPECTIONS, TESTS, AND OTHER SERVICES SPECIFIED IN INDIVIDUAL SPECIFICATION SECTIONS AND AS REQUIRED BY THE ARCHITECT/ENGINEER OR THE OWNER: C) INSPECTING, TESTING, AND SOURCE QUALITY CONTROL MAY OCCUR ON OR OFF THE PROJECT SITE. PERFORM OFF-SITE INSPECTING OR TESTING AS REQUIRED BY THE ARCHITECT/ENGINEER OR THE OWNER. D) REPORTS WILL BE SUBMITTED BY THE INDEPENDENT FIRM TO THE ARCHITECT/ENGWEER,IN DUPLICATE, INDICATING OBSERVATIONS AND RESULTS OF TESTS AND INDICATING COMPLIANCE OR NONCOMPLIANCE WITH CONTRACT DOCUMENTS. WRITTEN INSPECTION TEST REPORTS SHALL INCLUDE: 1. TESTAGENCYNAME 2. DATES AND LOCATIONS OF SAMPLES, TESTS, OR INSPECTIONS. 3. NAME OF INDIVIDUALS PRESENT. 4. COMPLETE INSPECTION OR TEST DATA. 5. TEST RESULTS AND INTERPRETATIONS. 6. RECOMMENDATIONS. E) COOPERATE WITH INDEPENDENT FIRM; FURNISH SAMPLES OF MATERIALS, DESIGN MIX, EQUIPMENT, TOOLS, STORAGE, SAFE ACCESS, AND ASSISTANCE BY INCIDENTAL LABOR AS REQUESTED. 1. NOTIFYARCHITECT/ENGINEERAND INDEPENDENT FIRM FORTY EIGHT (48) HOURS PRIOR TO EXPECTED TIME FOR OPERATIONS REQUIRING SERVICES. 2. MAKE ARRANGEMENTS WITH INDEPENDENT FIRM AND PAY FOR ADDITIONAL SAMPLES AND TESTS REQUIRED FOR CONTRACTOR'S USE. F) TESTING OR INSPECTING DOES NOT RELIEVE CONTRACTOR TO PERFORM WORK TO CONTRACT REQUIREMENTS. G) RETESTING REQUIRED BECAUSE OF NON-CONFORMANCE TO SPECIFIED REQUIREMENTS SHALL BE PERFORMED BY THE SAME INDEPENDENT FIRM ON I STRUCTIONS BY THE ARCHITECTlENGINEER. PAYMENT FOR RETESTING WILL N BE CHARGED TO THE CONTRACTOR BY DEDUCTING WSPECTWG OR TESTING CHARGES FROM THE CONTRACT SUM/PRICE. ARTICLE 30 - SUBSTITUTIONS A) ARCHITECT/ENGINEER WILL CONSIDER REQUESTS FOR SUBSTITUTIONS ONLY WITHIN FIFTEEN DAYS AFTER DATE ESTABLISHED IN NOTICE TO PROCEED. B) SUBSTITUTIONS MAY BE CONSIDERED WHEN A PRODUCT BECOMES UNAVAILABLE THROUGH NO FAULT OF THE CONTRACTOR. C) DOCUMENT EACH REQUEST WITH COMPLETE DATA SUBSTANTIATING COMPLIANCE OF PROPOSED SUBSTITUTION WITH CONTRACT DOCUMENTS. D) A REQUEST CONSTITUTES A REPRESENTATION THAT THE CONTRACTOR: 1. HAS INVESTIGATED PROPQSED PRODUCT AND DETERMINED THAT IT MEETS OR EXCEEDS THE QUALITY LEVEL OF THE SPECIFIED PRODUCT. 2. WILL PROVIDE THE SAME WARRANTY FOR THE SUBSTITUTION AS FOR THE SPECIFIED PRODUCT. 3. WILL COORDINATE INSTALLATION AND MAKE CHANGES TO OTHER WORK WNICH MAY BE REQUIRED FOR THE WORK TO BE COMPLETE WITH NO ADDITIONAL COST TO OWNER. WHICH MAY SUBSEQUENTLY BECOME APPARENT. 4. WAIVES CLAIMS FOR ADDITIONAL COSTS OR TIME EXTENSION 5. WILL REIMBURSE OWNER FOR REVIEW OR REDESIGN SERVICES ASSOCIATED WITH PRE-APPROVAL BY AUTHORITIES. E} SUBSTITUTIONS WILL NOT BE CONSIDERED NMEN THEY ARE INDICATED OR IMPLIED ON SHOP DRAWING OR PRODUCT DATA SUBMITTALS, WITHOUT SEPARATE WRITTEN REQUEST, OR VtMEN ACCEPTANCE WILL REQUIRE REVISION TO THE CONTRACT DOCUMENTS. F) SUBSTITUTION SUBMITTAL PROCEDURE: 1. SUBMIT THREE COPIES OF REQUEST FOR SUBSTITUTION FOR CONSIDERATION. LIMIT EACH REQUEST TO ONE PROPOSED SUBSTITUTION. 2. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND CERTIFIED TEST RESULTS ATTESTING TO TNE PROPOSED PRODUCT EQUIVALENCE. BURDEN OF PROOF IS ON PROPOSER. 3. THE ARCHITECT/ENGINEER WILL NOTIFY CONTRACTOR IN WRITING OF DECISION TO ACCEPT OR REJECT REQUEST. ARTICLE31-CLOSEOUTPROCEDURES A) SUBMIT WRITTEN CERTIFICATION THAT CONTRACT DOCUMENTS HAVE BEEN REVIEWED, WORK HAS BEEN INSPECTED, AND THAT WORK IS COMPLETE IN ACCORDANCE WITH CONTRACT DOCUMENTS AND READY FOR OWNER'S REVIEW. B) PROVIDE SUBMITTAIS TO ARCHITECT/ENGINEER THATARE REQUIRED BY GOVERtdING OR OTHERAUTHORITIES. C) SUBMIT FINAL APPLICATION FOR PAYMENT IDENTIFYING TOTAL ADJUSTED CONTRACT SUM, PREVIOUS PAYMENTS, AND SUM REMAINING DUE. ,� g� �API��IICH SFIUF�, 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 � � r �.�..� � � � � Q ��/ I..L J N JC M `Gn � W v � � z Z � � � U C� W � N � � 1.{� � z � U r � � � 0 � 0 N d w m � � Z H U w 0 � a q0P'����_ ` �� 4vO�96 �et'�-_- ��°`a � o h 6 £ '� i { � � �� � x �. , �'' a t`.,, ., C:� - a -; `��.'+ � �° ��� �:, �� „' d. .. � 7.✓�4" c� '� �� � � t �: � � :�' . SHEET TITLE ARCHITECTURAL SPECIFICATIONS SHEET NUMBER AS1.0 ARTICLE 32 - FINAL CLEANING A) EXECUTE FINAL CLEANING PRIOR TO FINAL PROJECTASSESSMENL B) CLEAN INTEWOR AND EXTERIOR GLASS; SURFACES EXPOSED TO VIEW; REMOVE TEMPORARY LABELS, STAINS AND FOREIGN SUBSTANCES, POLISH TRANSPARENTANDGLOSSYSURFACES. C) CLEAN EQUIPMENT AND FIXTURES TO A SANITARY CONDITION WITH CLEANINGMATERIALS APPROPRIATE TO THE SURFACE AND MATERIAL BEING CLEANED. D) REPLAGE FILTERS OF OPER4TING EQUIPMENT. E) CLEAN DEBRIS FROM ROOFS, GUTTERS, DOWNSPOUTS, AND DRAINAGE SYSTEMS. F) CLEAN SITE; SWEEP PAVED AREAS. G) REMOVE WASTE AND SURPLUS MATERIALS, RUBBISH, AND CONSTRUCTION FACILITIES FROM THE SITE. ARTICLE 33 - PROJECT RECORD DOCUMENTS A) MAINTAIN ON SITE, ONE SET OF THE FOLLOWWG RECORD DOCUMENTS; RECORD ACTUAL REVISIONS TO THE WORK: 1. DRAWINGS. 2. SPECIFICATIONS. 3. ADDENDA. 4. CHANGE ORDERS AND OTHER MODIFICATIONS TO THE CANTRACT. 5. REVIEWED SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. 6. MANUFACTURER'S INSTRUCTION FOR ASSEMBLY, WSTALL4TION, AND ADJUSTING. B) ENSURE ENTRIES ARE COMPLETE AND ACCURATE, ENABLINGFUTURE REFERENCE BY ONMER. C) STORE RECORD DOCUMENTS SEPAR4TE FROM DOCUMENTS USED FOR CONSTRUCTION. D) RECORD INFORMATION CONCURRENT WITH CONSTRUCTION PROGRESS. E) SPECIFICATIONS: LEGIBLY MARK AND RECORD AT EACH PRODUCT DESCRIPTION OF ACTUAL PRODUCTS INSTAILED, INCLUDING THE FOLLOWING: L MANUFACTURER'S NAME AND PRODUCT MODELAND NUMBER. 2 PRODUCT SUBSTITUTIONS OR ALTERNATES UTILIZED. 3. CHANGES MADE BY ADDENDA AND MODIFICATIONS. F) RECORD DOCUMENTS AND SHOP DRAWINGS: LEGIBLY MARK EACH ITEM TO RECORD AGTUAL CONSTRUCTION INCLUDWG 1. MEASURED HORIZONTAL AND VERTICAL LQCATIONS OF UNDERGROUND UTILITIES AND APPURTENANCES, REFERENCED TO PERMANENT SURFACE IMPROVEMENTS. 2. MEASURED LOCATIONS OF INTERNAL UTItITIES AND APPURTENANCES CONCEALED IN CONSTRUCTION, REFERENCED TO VISIBLE AND ACCESSIBLE FEATURES OF THE WORK 3. FIELD CHANGES OF DIMENSION AND DETAIL. 4. DETAILS NOT ON ORIGINAL CONTRACT DRAWINGS. G) REMOVE ARCHITECTIENGINEERTITLE BLOCKAND SEAL FROM ALL DOCUMENTS. H) FOLLOW CLOSE OUT PROCEDURE FROM PRE-CONSTRUCTION MEETWG. ARTICLE 34 - OPERATION AND MAINTENANCE DATA A) FOR EACH PIECE OF OPERATING EQUIPMENT FURNISHED UNDER THIS CONTRACT, SUBMIT TO THE OWNER CONSOLIDATED OPERATIONAND MAINTENANCE DATA WCLUDING THE FOLLOWING. 1. PURCHASE, INSTALLATION, BALANCING, AND ADJUSTMENT RECQRDS, AS APPLICABLE. 2. MANUFACTURER'S INSTRUCTIONS FOR OPERATION, MAINTENANCE, DIAGNOSTICS, AND ADJUSTMENT PROCEDURES, AS APPROPRIATE. 3. CONTACT INFORMATION FOR SERVICE. 4. WARRANTY. B) WAIVER OF THESE 0&M DATA SUBMITTAL REQUIREMENTS ARE SUBJECT TO APPROVAL BY THE OWNER'S REPRESENTATIVE.. ARTICLE 35 - WARRANTIES A) EXECUTE AND ASSEMBLE TRANSFERABLE WARRANTY DOCUMENTS FROM SUBCONTRACTORS,SUPPLIERS,AND MANUFACTURERS. B) FOR ITEMS OF WORK DELAYED BEYOND DATE OF SUBSTANTIAL COMPLETION, PROVIDE UPDATED SUBMITTAL WITHIN FIFTEEN DAYS AFTER ACCEPTANCE, LISTING DATE OF ACCEPTANCE AS START OF WARRANTY PERIOD: C) SUBMIT PRIOR TO FINAL APPLICATION FOR PAYMENL ARTICLE 36 - SPARE PARTS AND MAINTENANCE MATERIALS A) PROVIDE PRODUCTS, SPARE PARTS, MAINTENANCE AND EXTRA MATERIALS W QUANTITIES SPECIFIED IN INDIVIDUAL SPECIFICATION SECTIONS. B) DELIVER TO PROJECT SITE AND PLACE IN LOCATION AS DIRECTED; OBTAIN RECEIPT PRIOR TO FINAL PAYMENL GENERAL SPECIFICATIONS DIVISION 01-GENER4L REQUIREMENTS 013300-SUBMITTALPROCEDURES t. GENERAL A. SUMMARY: SECTION INCLUDES i) SUBMITTALFORMREQUIREMENTS 2� SUBMITTAL SCHEDULE 3) CONTRACTOR RESPONSIBILITIES a) REQUIREMENTS FOR EACH TYPE OF SUBMITTAL e. SUBMITTAL FORM REQUIREMENTS: PROVIDETHE FOLLOWING, AS APPLICABLE ON EACH SUBMITTAL: 1) PRESENT AND PREVIOUS SUBMITTAL DATES. z) THE PROJECT TITLE AND NUMBER. a) CONTRACTOR'SSUBMITfALNUMBER. 4) SUBCONTRACT IDENTIFICATION. 5) THE NAMES OF: A) CONTRACTOR. s) SUPPLIER. c) MANUFACTURER. s) IDENTIFICATION OF REVISIONS ON RESUBMITTALS. � POR EACH PRODUCT, REFERENCE CORRESPONDING SPECIFICATION AND PARAGRAPH NUMBER. a� A 6 X 41NCH BLANK SPACE FOR STAMPS. c. DELNER SUBMITTALS TO THE OWNER'S REPRESENTATNE. INCLUDE NAME OF CONTACT PERSON IDENTIFIED AT THE TIME OF AGREEMENT. o. SUBMITTALS IN GRAPHIC FORM SHALL BE CLEAR READABLE COPIES WITN CONTRACTOR'S OWGINAL STAMR E. SUBMITTALSCHEDULE t) MAKE SUBMITTALS AS REQUIRED TO CAUSE NO DELAY IN THE WORK. 2) REQUIRE EACH SUBCONTRACTOR TO MAKE SUBMITTALS WITHIN 60 DAYS OF THE SUBCONTRACT DATE, UNLESS SPECIFIED OR APPROVED OTHERWISE, OR REQUIRED TO MEET THE WORK SCHEDULE. 3) SCHEDULE SUBMITTALS TO ALLOW SUFFICIENT TIME FOR POSSIBLE REVISION AND RESUBMITTAI OF THE REJEC�TED SUBMITTALS, WITHOUT AFFECTING TNE CONSTRUCTION SCHEDULE. a) MAKE THE FOLLOWING SUBMITTALS PRIOR TO STARTING CONSTRUCTION : A) CERTIFICATES OF WSURANCE. B) LIST OF SUBCONTR4CTORS AND SUPPLIERS. c) CONSTRUCTION SCHEDULE D} SUBMITTAL LOG. RRODUCTS LISL F. GENER4L SUBMITTAL REQUIREMENTS t) MAKE SUBMITTALS AS REQUESTED, AS REQUIRED BY INDIVIDUAL SPECIFICATION SECTIONS, AND AS OTHERWISE NECESSARY TO CONFIRM INTENT OR COMPLIANCE. SUBMITTALS FOR OWNER FURNISHED PRODUCTS ARE NOT REQUIRED. 2) REVIEW SUBMITTAL MATERIALS PRIOR TO SUBMITTAL. VERIFY SPECIFIED REQUIREMENTS FOR PRODUCTS, FIELD MEASUREMENTS, AND FIELD CONSTRUCTION REQUIREMENTS. 3) STAMP AND SIGN EACH SUBMITTAL AS CERTIFICATION THAT THE SUBMITtACHAS BEEN REVIEWED BY THE CONTRACTOR. SUBMITTALS NOT STAMPED AND SIGNED BY THE CONTRACTOR WILL BE RETURNED. a) NOTE IN WRITING, AT TIME OF SUBMITTAL, ALL DEVIATIONS IN THE SUBMITTALS FROM REQUIREMENTS OF THE CONTRACT DOCUMENTS. 5) MAKE COPIES OF ALL APPROVED SHOP DRAWINGS AND PRODUCT LITERATURE AVAILABLE FOR USE IN THE PROJECT. s) REVIEW AND APPROVAL OF A SUBMITTAL SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE PROPER FITTWG, FINISHING, QUANTITIES, AND ERECTION OF THE WORK IN STRICT ACCORDANCE WITH THE CONTRACT REQUIREMENTS. 7) REVIEW AND APPROVAL OF A SUBMITTAL SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY FOR PROVIDING WORK NOT INDICATED ON THE SUBMITTAL, BUT OTHERWISE REQUIRED FOR THE COMPLETION OF THE WORK. a) DO NOT FABRICATE OR ERECT WORK PRIOR TO APPROVAL OF THE SUBMITfALS. s) SHOULD DISCREPANCIES BECOME EVIDENT, IMMEDIATELY NOTIFY ARCHITECT FOR RESOLUTION BEFORE PROCEEDING WITH SHOP WORK. �o) INCLUSION OF SUBSTITUTION REQUESTS INTO SUBMII'TALS WILL BE CONSIDERED CAUSE FOR REJECTION OF THE SUBMITTAL. � �) SUBMITTALS WILL BE REVIEWED FOR CONFORMANCE TO THE DESIGN CONCEPT, ONLY. REVIEW OF VENDOR DESIGNED ITEMS SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR COMPLIANCE WITH SPECIFIED PERFORMANCE REQUIREMENTS. �. CONSTRUCTION SCHEDULE �) SHOW COMMENCEMENT AND COMPLETION DATES PROPOSED FOR EACH SUBDIVISION OF WORK. 2) COORDINATE WITH THE OWNER'S SCHEDULE, SHOWING ALL CONTRACT ACTIVITIES TO BE PERFORMED BY THE OWNER INCLUDING THEIR START,pURATION, COMPLETION, PLOAT AND CRITICAL PATH. ti. SHOP DRAWINGS �) SUBMIT SNOP DRAWINGS REQUIRED BY INDNIDUAL SECTIONS OF THE SPECIFICATIONS, AND AS OTHERWISE REQUIREU FOR PROPER PERFORMANCE OF THE WORK. z) ILLUSTRATE FULLY THE REQUIREMENTS OF THE SPECIFICATIONS ANp THE CONTRACT DRAWINGS, AND ACCURATELY SHOW QUANTITIES, KINDS OF MATERIALS, METHODS OF ASSEMBLY, AND ALl DATA REQUIRED FOR FABRICATION, ERECTION, AND INSTALLATION. a) SHOW THE RELATIONSHIP OF ADJOINING WORK, RELEVANT FIELD CONDITIONS AND DIMENSIONS; COORDINATE WITH AFFECTED SUBCONTRACTORS AND SUPPLIERS IF W CONFLICL a) NUMBER OF COPIES: UNLESS OTNERWISE SPECIFIED, SUBMIT 2 LEGIBLE RIGHT-READING COPIES TO THE ARCHITECT, POTBELLY FOR REVIEW. 5) THE ARCHITECT, POTBELLY WILL RETURN ONE COPY TO CONTRACTOR WITH CORRECTIONS, NOTATIONS AND STAMP INDICATING ACTION TO BE TAKEN: i. PRODUCTDATA �) MARK EACH COPY TO IDENTIFY APPLICABLE PRODUCTS, MODELS, OPTIONS, AND OTHER DATA. INCLUDE MANUFACTURER'S PRINTED 1NSTALLATION INSTRUCTIONS. z) SUBMIT TNE NUMBER OF COPIES WHICH CONTRACTOR REQUIRES, PLUS 1COPY WHICH WILL BE RETAMED BYARCHITECT, POTBELLY. 3) MODIFY PRODUCT DATA AND WSTALLATION INSTRUCTIONS TO DELETE INFORMATION WHICH IS NOT APPLICABLE TO THE WORK. 4� SUPPLEMENT STANDARD INFORMATION TO PROVIDE INFORMATION SPECIFICALLY APPLICABLE TO THE WORK. �. SAMPLES 1) SUBMIT SAMPLES AS SPECIFIED IN THE TECHNICAL SECTIONS. 2) WCLUDE IDENTIFICATION ON EACH SAMPLE, GIVING FULL WFORMATION. 3) SUBMIT THE NUMBER OF SAMPLES SPEGFIED IN THE TECHNICAL SECTIONS. V�MERE QUANTITY IS NOT SPECIFIED, SUBMIT 3 SAMPLES. 4) SUBMIT SAMPLES TO ILLUSTRATE FUNCTIONAL CHARACTERISTICS OF THE PRODUCT, WITH INTEGRAL PARTS AND ATTACHMENT DEVICES. COORDINATE SUBMITTAL OF DIFFERENT CATEGORIES FOR INTERFACING WORK. K. SUSTAINABLE DESIGN AND CONSTRUCTION 1) FOR WORK UNDER EACH SUBCONTRACT OR SPECIFICATION SECTION, MAKE SUBMITTALS AS NECESSARY TO SUPPORT EACH APPLICABLE CREDIT, AS DESCRIBED IN SECTION 018113. 2) MAKE SUBMITTALS AS NECESSARY TO SUPPORT PROCEDURAL REQUIREMENTS, INCLUDING WASTE MANAGEMENT AND INDOOR AIR QUALITY MANAGEMENT PLANS, AS DESCRIBED IN SECTION 018113. �15000 - TEMPORARY FACILITIES A. TEMPORARY HEATING: PROVIDE TEMPORARY HEAT TO PROTECT WORK AND MATERIALS AGAINST INJURY FROM DAMPNESS AND COLD AND TO DRY OUT BUILDING. FUEL, EQUIPMENT, AND METHOD OF HEATING SATISFACTORY TO ARCHITECT. MINIMUM TEMPER4TURE FOR WORK 50 DEGREES FAHRENHEIT. B. TEMPORARY UTILITIES: ARRANGE FORAND FURNISH WATER, GASAND ELECTRICITY TO DATE OF OCCUPANCY BY OWNER. FURNISH ELECTRICITY FOR LIGHT AND POWER DURING CONSTRUCTION PERIOD INCLUDIN� LAMPS. OTHER CONTRACTORS USING TEMPORARY SERVICES SHALL PAY FOR ALL DAMAGES TO LIFE, LIMB OR PROPERTY WHICH RESULT FROM THEIR USE OF TEMPORARY SERVICES. c. SANITARY CANVENIENCES: PROVIDE SANITARY CONVENIENCES REQUIRED FOR WORKMEN AND MAINTAIN SAME IN SANITARY CONDITION. D. TEMPORARY TELEPHONE AND FAX SERVICE: PROVIDE JOB TELEPHONE, LISTED WITH TELEPHONE COMPANY UNDER THE NAME OF THE GENERAL CONTRACTOR. TELEPHONE, PORTABLE TELEPHONE AND FAX MACHINE TO BE INSTALLED IMMEDIATELY UPON START OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF CONSTRUCTION. POTBELLY SANDWICH WORKS WILL ARRANGE FOR INSTALLATION OF PERMANENT SERVICE AT THE TIME OF OCCUPATION OF BUILDING. PHONE TO HAVE OUTSIDE BELL OR BUZZER. E. PROVIDE AND MAINTAIN ALL NECESSARY TEMPORARY STAIRS, LADDERS, RAMPS, PLATFORMS, HOISTS, ETC., AS REQUIRED FOR PROPER EXECUTION OF THE WORK, ALL OF WHICH SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL CODES. 01600� - PRODUCT REQUIREMENTS a. DELIVERY, STOR4GE, AND HANDLING: 1) TR4NSPORT AND HANDLE PRODUCTS BY METHODS TO AVOID PRODUCT DAMAGE. 2) MANUFACTURED PRODUCTS SHALL REMAIN IN MANUFACTURER'S CONTAINERS OR PACKAGING, STORED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, UNTIL READY FOR INSTALLATION. 3) PRODUCTS INDICATED OR SCHEDULED AS VENDOR-FURNISHED WILL BE PAID FOR BY THE OWNER AND DELIVERED TO THE SITE. COORDINATE WITH THE OWNER. a) PRODUCTS AND MATERIALS DAMAGED AFTER ACCEPTANCE OF DELIVERY SHALL BE REPLACED WITH NEW LIKE PRODUCTS, AT NO ADDITIONAL COST TO TNE OWNER. e. GENERAL INSTALIATION REQUIREMENTS �) ENVIRONMENTAL REQUIREMENTS: MAINTAIN TEMPERATURE RANGES, HUMIDITY, AND PROTECTION PROVISIONS IN ACCORDANCE WITH MANUPACTURER'S RECOMMENDATIONS. 2) EXAMINATION n) PRIOR TO STARTING WORK, INSPECT INSTALLED WORK OF OTHER TRADES AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT NMERE WORK MAY PROPERLY COMMENCE. s) REQUIRE CORRECTION OF CONDITIONS DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF THE WORK. c) BEGINNWG WORK CANSTITUTES ACCEPTANCE OF SITE CONDITIONS AND RESPONSIBILITY FOR DEFECTIVE INSTALLATION CAUSED BY PRIOR OBSERVABLE CANDITIONS. 3) UNLESS INDICATED OR SPECIFIED OTHERWISE, INSTA�L EACH PRODUCT IN ACCORDANCE WITH THE PRODUCT MANUFACTURER'S INSTRUCTIONS. a) MAINTAIN ONE SET OF COMPLETE INSTRUCTIONS AT THE JOB SITE DURING INSTALLATION AND UNTIL COMPLETION. c. PRODUCT OPTIONS 1) PRODUCT SPECIFIED BY REFERENCE STANDARDS OR BY DESCRIPTION ONLY: PROVIDE PRODUCT MEETING THOSE STANDARDS. 2) PRODUCT SPECIFIED BY NAMING ONE OR MORE MANUFACTURERS WITH AN "OR APPROVED" PROVISION: USE SPECIFIED PRODUCT OR SUBMIT A REQUEST FOR SUBSTITUTION IN ACCORDANCE WITH THE SPECIFIED SUBSTITUTION REQUIREMENTS. WHEN APPROVED A SUBSTITUTE PRODUCT MAY BE USED. 3) PRODUCT SPECIFIED BY NAMING ONE OR MORE MANUFACTURERS, WITHOUT A PROVISIONS FOR SUBSTITUTION: NO SUBSTITUTION WILL BE ALLOWED, EXCEPT AS SPECIFIED UNDER THE ARTICLE ON SUBSTITUTIONS. D. SUBSTITUTIONS: IN ACCORDANCE WITH THE GENERAL AND SUPPLEMENTARY CONDITIONS, AND AS FOLLOWS. �) FURNISH PRODUCTS SPECIFIED, EXCEPT WHERE "ORAPPROVED" IS USED; SUBSTITUTE PRODUCTS MAY BE SUBMITTED TO ARCHITECT FOR APPROVAL. 2) SUBSTITUTIONS WILL BE CONSIDERED ONLY FOR THE FOLLOWING REASONS: n) A PRODUCT BECOMES UNAVAILABLE DUE TO NO FAULT OF THE CONTRACTOR. B) A SUBSTITUTE PRODUCT WILL BE IN OWNER'S BEST INTEREST BY PROVIDING A COST SAVINGS, PRODUCT QUALITY OR UTILITY ADVANTAGE, OR SCHEDULE BENEFIL 3) DOCUMENT EACH SUBSTITUTION REQUEST WITH COMPLETE DATA SUBSTANTIATING COMPLIANCE OF PROPOSED SUBSTITUTION WITH CONTRACT DOCUMENTS. 4) A SUBSTITUTION REQUEST CONSTITUTES A REPRESENTATION THAT CONTRACTOR: A) HAS INVESTIGATED PROPOSED PRODUCTAND HAS DETERMINED THAT IT MEETS-0R EXCEEDS PERFORMANCE OF THE SPECIFIED PRODUCT, IN ALL RESPECTS. a) SHALL PROVIDE THE SAME WARRANTY FORSUBSTITUTION ASfOR SPECIFIED PRODUCT. C) WILL COORDINATE INSTALLATION AND MAKE OTHER CHANGES WHICH MAY BE REQUIRED FOR WORK TO BE COMPLETE IN ALL RESPECTS. o� WAIVES CLAIMS FOR ADDITIONAL COSTS THAT MAY SUBSEQUENTLY BECOMEAPPARENT. E) AGREES TO PAY ALL COSTS OF REDESIGN RELATED TO THE SUBSTITUTION. 5) UNLESS PREVIOUSLY APPROVED, SUBSTITUTIONS IMPLIED ON SHOP DRAWINGS WILL NOT BE ACCEPTED. s) THE ARCHITECT WILL DETERMINE ACCEPTABILITY OF PROPOSED SUBSTITUTION, COORDINATE WITH THE OWNER, AND WILL NOTIFY CONTRACTOR OF ACCEPTANCE OR REJECTION WITHIN A REASONABLE TIME. 018113 - SUSTAINABLE DESIGN REQUIREMENTS 1. GENER4L n. SUMMARY �) WHERE PRACTICAL, THIS PROJEGT WILL VOLUNTARILY COMPLY WITH USGBC REQUIREMENTS FOR SUSTAINABLE DESIGN AND CONSTRUCTION FOR NEW CONSTRUCTION AS SPECIFIED. z) EXCEPT AS OTHERWISE INDICATED, WHERE SUBMITTALS ARE REQUIRED TO DOCUMENT COMPLIANCE WITH DESIGN INTENT, SUBMITTALS FOR VERIFICATION OF ITEMS SUCH AS SUSTAINABLE S�TES REQUIREMENTS, WATER EFFICIENCY, ENERGY PERFORMANCE, THERMAL COMFORT, AND FACILITY OPERATION ARE OUTSIDE THE SCOPE OF THIS CONTRACT. e. REFERENCES �) LEED REFERENCE GUIDE FOR BUILDING DESIGN AND CONSTRUCTION, 2009 EDITION. 2� LEED REFERENCE GUIDE FOR BUILDING DESIGN AND CONSTRUCTION - RETAIL SUPPLEMENT, 2009 EDITION. c. REQUIREMENTS �) MAKE SUBMITTALS AS SPECIPIED, AS REQUESTED, AND NECESSARY TO SUPPORT SPECIFIC SUSTAINABILITY REQUIREMENTS. z) TRACK MATERIALS AND PROCEDURES AS NECESSARY TO VERIFY ACHIEVEMENT OF OBJECTIVES 3) COORDINATE THE WORK TO INTEGRATE THE WORK AMONG REQUIREMENTS FOR AIR QUALITY MANAGEMENT, CONSTRUCTION WASTE MANAGEMENT, AND COMMISSIONING. 2. PRODUCTS-NOTUSED 3. EXECUTION A. GENERAL �) CORRECTION OF WORK NOT CONFORMING WITH SPECIFIED SUSTAINABILITY REQUIREMENTS SHALL BE PERFORMED AT CONTRACTOR'S EXPENSE. 2) SUSTAINABILITY INTRODUCTION MEETING: ADDRESS AS A SEPAR4TE AGENDA ITEM AN ORIENTATION SESSION TO FAMILIARIZE CONSTRUCTION FORCES WITH SUSTAINABILITY INTENT. e. SUSTAINABILITY OBJECTIVES �) INTENT A) PERFORM WORK TO QUALIFY FOR THE FOLLOWING LEED-NC EQUIVALENT PREREQUISITES AND CREDITS. UNLESS OTHERWISE INDICATED, WHERE CONTRACTOR-AND OWNER-FURNISHED MATERIALS AND EQUIPMENT ARE CONTRIBUTORY, DOCUMENT TO INDICATE AGGREGATE CONTRIBUTIONS TO ACHIEVE CREDITS AT THE LEVELS INDICATED. CAMPLY WITH REFERENCED DOCUMENTS FOR SPECIFIC REQUIREMENTS. s) WHERE TARGET PERCENTAGES ARE INDICATED, MEET OR EXCEED THOSE REQUIREMENTS TO THE GREATEST REASONABLE EXTENT. 2) WATEREFPICIENCY n) WE CREDIT 2- WATER USE REDUCTION: WATER USING APPLIANCES AND FIXTURES SHALL EXCEED BASELINE LEVELS BYA MINIMUM 30 PERCENT. 3) ENERGYANDATMOSPHERE a) EA PREREQUISITE 1- FUNDAMENTAL COMMISSIONING OF BUILDING ENERGY SYSTEMS: COORDINATE WITH OWNER FOR STARTUP AND COMMISSIONING OF HVAC e) EA PREREQUISITE 3- FUNDAMENTAL REFRIGERANT MANAGEMENT: VERIhI' REFRIGERANT TYPE. a) MATERIALS AND RESOURCES a� MRCREDIT2-CONSTRUCTIONWASTEMANAGEMENT: SUBMITAS REQUIRED TO DOCUMENT SORTING, QUANTITIES, AND DISPOSITION AND DIVERSION OF CONSTRUCTION WASTE INCLUDING (1) CONCRETE (2) WOOD (3) GYPSUM (4) CARDBOARD (5) PLASTIC (6) MIXED WASTE e) MR CREDIT 4- RECYCLED CONTENT: MINIMUM 10 PERCENT INCORPORATED RECYCLED CONTENT, BASED ON COST AND DETERMINED BY SUMAF POST-CONSUMER PLUS 1/2 PRE-CONSUMER RECYCLED CONTENT. c) MR CREDIT 5- REGIONAL MATERIALS: MINIMUM 20 PERCENT OF MATERIALS AND PRODUCTS, BASED ON COST OF COMPONENTS AND CONTENTEXTRACTED,HARVESTED,RECOVERED,OR MANUFACTURED WITHIN 500 MILES OF THE PROJECT SITE. �) MR CREDIT 7- CERTIFIED WOOD: MINIMUM 50 PERCENT, BASED ON RELATIVE COST OF INCORPORATED CONTENT, WOOD AND WOOD PRODUCTS CERTIFIED BY THEFOREST STEWAROSHIP COUNCIL 5) INDOORENVIRONMENTALQUALITY. A) IEQ CREDIT 3.1; 32 - CONSTRUCTION IAQ MANAGEMENT PLAN: DEVELOP AND IMPLEMENT AN IAQ MANAGEMENT PLAN FOR CONSTRUCTION AND PRE-OCCUPANCY PHASES OF THE BUILDING. ry) MEET OR EXCEED RECOMMENDED CONTROL MEASURES OF SMACNA IAQ GUIDELINES FOR OCCUPIED BUILDINGS UNDER CONSTRUCTION, 2ND EDITION 200Z (2) PROTECT ONSITE AND INSTALLED ABSORPTIVE MATERIALS FROM MOISTURE. (3) FORHVACEMPLOYEDDURINGCONSTRUCTION,USEMINIMUM MERV 8 FILTRATION. REPLACE FILTRATION MEDIA IMMEDIATELY PRIOR TO PROJECT TURNOVER. (a) AFTER CONSTRUCTION ENDS AND PWOR TO OCCUPANCY, PERFORM PROJECT AREA FLUSH-OUT BY SUPPLYING A TOTAL AIR VOLUME OF 14,000 CF OF OUTDOOR AIR PER SF OF PROJECT FLOOR AREA. B) IEQ CREDIT 4- LON! EMITTING MATERIALS. (�) CREDIT 4.1- ADHESIVES AND SEALANTS: LIMIT VOC CONTENT OF EACH RAW MATERIAL IN ACCORDANCE WITH SCAQMD RULE 1168, AMENDED JANUARY 7, 2005; LIMIT AEROSOL ADHESIVES IN ACCORDANCE WITH GREEN SEAL GS-36, EFFECTIVE OCTOBER 19, 2000. (2) CREDIT 42 - PAINTS AND COATINGS: LIMIT VOC CONTENT OF EACH RAW MATERIAL IN ACCORDANCE WITH GREEN SEAL GS-11, EFFECTIVE MAY 20,1993; LIMIT ANTI-CORROSIVE AND ANTI-RUST PAINTS TO 250 G/L; LIMIT CLEAR WOOD FINISHES, FLOOR COATINGS, STAINS, PRIMERS AND SHELLACS IN ACCORDANCE WITH SCAQMD RULE 1113, EFFECTIVE JANUARY 1, 2004. (3) CREDIT 4.3 - FLOORING SYSTEMS: (a) RESILIENT FLOORINGAND BASE; CERAMIC TILE FLOORWG CERTIFIED AS COMPLIANT WITH CALIFORNIA DEPARTMENT OF HEALTH SERVICES (FLOOR SCORE). (b) TILE SETf WG ADHESIVES: LIMIT VOC CONTENT OF EACH RAW MATERIAL IN ACCORDANCE WITH SCAQMD RULE 1168, AMENDED JANUARY 7, 2005. (4) CREDIT 4.4 - COMPOSITE WOOD AND AGRIFIBER PRODUCTS: VERIFY FREEDOM FROM ADDED UREFLFORMALDEHYDE. (5) CREDIT 4.6 - CEILWG AND WALL SYSTEMS: VERIFY COMPLIANCE WITH CALIFORNIA DHS STANDARD PRACTICE FOR TESTING OF VOLATILE ORGANIC EMISSIONS, INCLUDING 2004 ADDENDA. DIVISION 02 - EXISTING CONDITIONS 024119 - SELECTIVE DEMOLITION A. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER AS REQUIRED TO ACCOMMODATE THE WORK. WHERE DEMOLITION EXCEEDS THAT INDICATED, VERIFY SUCH DEMOLITION WITH THE ARCHITECT AND THE LANDLORD PRIOR TO PROCEEDING. s. NOTIFYTHELANDLORDPRIORTOCUTTINGORFASTENINGJNTO CONCRETE SLABS: X-RAY AS DIRECTED AND AS NECESSARY TO DETERMINE LOCATION OF TENDONS; REINFORCING, OR UTILITIES. C. NOTIFY THE OWNER PRIOR TO COMMENCING DEMOLITION WORK, COORDINATE WITH OWNER FOR REMOVAL OF ITEMS TO BE CLAIMED. EXCEPT WHERE NOTED OR SPECIFIED OTHERWISE, TAKE POSSESSION OF MATERIALS BEING DEMOLISHED, AND IMMEDIATELY REMOVE FROM SITE. DO NOT OVERLOAD EXISTING CONSTRUCTION TO REMAIN WITH DEMOLISHED MATERIALS. o. PROVIDE A SMOOTH, EVEN, AND INVISIBLE TR4NSITION TO NEW CONSTRUCTION. WHEN FINISHED SURFACES ARE CUT SO THAT AN INVISIBLE TRANSITION WITH NEW WORK IS NOT POSSIBLE, TERMINATE EXISTING SURFACE ALONG THE NEAREST BREAK LINE, JOINT, OR CORNER. E. WHERE SLAB PENETRATIONS ARE INDICATED OR REQUIRED, X-RAY THE SLAB PRIOR TO CUTTING. NOTIFY THE ARCHITECT FOR RESOLUTION WHERE TENDONS, REINFORCING, OR EMBEDDED UTILITIES ARE DISCOVERED. F. REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED, AT NO ADDITIONAL COST TO THE OWNER. DIVISION 03-CONCRETE 030133 - CAST-IN-PLACE CONCRETE r. GENER4L n. SECTIONINCLUDES �) CONCRETE SLAB INFILL AND CURBS. 2) TRENCHING AND PIPE BEDDING. 3) CAST-IN-PLACE CONCRETE FOR INFILL OF TRENCHES. 2. PRODUCTS n. PLYWOOD: APA MEDIUM DENSITY OR HIGH DENSITY OVERLAY, PLYFORM CLASS t EXT. s. REINFORCING: AS INDICATED ON THE DRAWINGS. c. CONCRE7E MATERIALS: �) CEMENT: ASTM C150, NORMAI-TYPE 1 PORTLAND CEMENT. 2) NORMAL WEIGHT FINE AND COARSE AGGREGATES: ASTM C33. 3} WATER: CLEAN AND NOT DETRIMENTAL TO CONCRETE. a) ADMIXTURES A) WATER REDUCER NORMAL: ASTM C494, TYPE A. B) ACCELERATOR: ASTM C494, TYPE C OR E, NON-CORROSIVE, NON-CHLORIDE. o. ACCESSORIES t) BONDING AGENT: 2-COMPONENT MOISTURE INSENSITIVE,100 PERCENT SOLIDS EPDXY ADHESIVE WITH SHEAR BOND TO CONCRETE STRENGTH >1400 PSI. 2) CURING MATERIALS: WATERPROOF SNEET: ASTM C171; MINIMUM 4 MIL POLYETHYLENE SHEET OR REINFORCED WATERPROOF KRAFT PAPER. 3) WATERPROOf MEMBRANE: MATCH EXISTING, UNLESS APPROVED OTHERWISE.. 3. EXECUTION n. TRENCHING t) COORDINATE WITH DNISION 02, PLUMBING, AND MECHANICALWORKAS APPROPRIATE n) MAKE TRENCHES WITH SUFFICIENT WIDTH TO PERMIT INSTAU.ATION. s 0 E IS INDICATED OR REQUIRED ) WHERE WATERPR OF MEMBRAN , REPAIR DAMAGE TO EXISTING MEMBRANE AS NECESSARY TO MAINTAIN BARRIER BET4VEEN NEW CONSTRUCTION AND OCCUPIED SPACE BELOW. e. PLACEMENT 1) MIX CANCRETE IN ACCORDANCE WITH ASTM C94; MINIMUM 3000 PSI, 28 DAY COMPRESSIVE STRENGTH. z) PLACEMENTANDFINISHING n) USE BONDING AGENT AT INTERFACE WITH EXISTING SLAB EDGE a� PLACE REINFORCING AND CONCRETE IN ACCORDANCE WITH ACI 301. c) FINISH CONCRETE SLABS LEVELAS INDICATED ON THE DRAWINGS. o) FULLTROWELFINISHINTERIORFLOORSLABSURFAGESTOMATCH ADJACENT WORK c. CURING: MOISTURE CURE ALL CONCRETE FORA MINIMUM OF 7 DAYS. 035416 - HYDR4ULIC CEMENT UNDERLAYMENT AND TOPPING t GENERAL n. SECTION INCLUDES LEVELING OF EXISTING CAST-IN-PLACE CONCRETE SLRBS. 2. PRODUCTS a. SELF LEVELING TOPPING SYSTEM: POURABLE, CEMENT BASED MATERIAL, TRAFFIC BEARING TYPE; MINIMUM 28 DAY COMPRESSIVE STRENGTH 6,000 PSI; MINIMUM BOND STRENGTH 200 PSI. t) BASIS OF DESIGN: MAPEI AMERICAS "ULTRATOP"; GRAY COLOR. 2) ACCEPTABLE OPTIONS (SUBJECT TO COMPLIANCE WITH CONTR4CT DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF CONFORMANCE TO DESIGN INTENT.): a) ARDEX INC. "SD-T" SELF-LEVELING SELF-DRYING CONCRETE TOPPING. B) PROSPEC "LEVEL SET WEAR TOPPING" s. SELF LEVELWG UNDERLAYMENT SYSTEM: POURABLE, CEMENT BASED MATERIAL, MINIMUM 28 DAY COMPRESSIVE STRENGTH 3,000 PSI; MINIMUM BOND STRENGTH 200 PSL 1) BASIS OF DESIGN: MAPEI AMERICAS "ULTRAPLAN 1 PLUS". 2) ACCEPTABLE OPTIONS (SUBJECT TO COMPLIANCE WITH CONTRACT DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF CONFORMANCE TO DESIGN INTENT.): A) ARDEX INQ "K-15" SELF-LEVELING UNDERLAYMENT CONCRETE. e) KOESTER AMERICAN CORPORATION "VAP-1 LEVEL PRO." c) SUPERCAP (HASLET TX; 866_704_2247) "SUPERCAP SELF-LEVELWG UNDERLAYMENT." o) PROSPEC"LEVELSET300° " TICRETE 86 LATILEVEL THIN � LATICRETE INTERNATIONAL, WC. LA POUR UNDERLAYMENT." C. REPAIR MORTAR: MAPEI AMERICAS "PLANITOP X," OR APPROVED. o. ACCESSORIES: FURNISH PRIMERS, PATCHING COMPOUNDS, AND SAND FILLERS AS NECESSARY FOR TROWELABLE APPLICATIONS AND AS RECOMMENDED BY THE UNDERLAYMENT MANUFACTURER FORTHE CONDITIONS OF THE PROJECL 3. EXECUTION n. GENERAL: 1) SURFACES SCHEDULED FOR SEALED CONCRETE: INSTALL CEMENTITIOUS TOPPING TO CONCRETE SLABS AS INDICATED ON THE DRAUVINGS, AND AS NECESSARY TO LEVEL SLABS OR BRING SUBSTRATES TO PROPER ELEVATION. 2) SURFACES TO RECEIVE SUBSEQUENT ADHERED FINISHES: WITH THE EXCEPTION OF AREAS WHERE LEVELING CAN BE ACCOMPLISHED BY USE OF LATEX UNDERLAYMENT, AS SPECIFIED IN SECTION 096519, INSTALL CEMENTITIOUS UNDERLAYMENT TO CONCRETE SLABS AS INDICATED ON THE DRAWINGS OR AS DETERMINED BY THE OWNER'S REPRESENTATIVE DURING FIELD VISIT, AND AS NECESSARY TO LEVEL SLABS OR BRING SUBSTRATES TO PROPER ELEVATION. 3) PROVIDE ADDITIONAL TOPPING AT LOCATIONS AS DIRECTED AND AS NECESSARY FOR MOCK-UPS OF STAIN AND SEALER SYSTEMS. a. PREPARATION �) SURVEY FLOOR AS NECESSARY TO SET SCREEDS AND REFERENCE POINTS. IDENTIFY CONSTRUCTION JOINTS, AND CONTROL JOINTS. PREPARE FOR UNDERLAYMENT AT ALL LOCATIONS WHERE FLOOR DOES NOT MEET SPECIFIED TOLERANCE REQUIREMENTS. 2) ENSURE THAT SUBFLOOR IS CLEAN, DRY, HARD, SOUND, AND FREE OF OILS, OR OTHER SUBSTANCE WHICH WOULD AFFECT PROPER BONDING AND CURING. VERIFY THAT ALL AREAS TO BE LEVELED ARE AT OR BELOW FINAL DESIGN ELEVATION. 3) COORDINATE WITH PLUMBING WORK AND SECTION 093000 FOR ESTABLISHMENT OF LEVELS AND PITCHES TO DRAIN. C. APPLICATION t) INSTALL TROWELABLE UNDERLAYMENT AT LOCATIONS WHERE SLOPES ARE INDICATED AND AT OTHER LOCATIONS AS APPROPRIATE TO INSTALLATION CONDITIONS; INSTALL SELF LEVELING UNDERLAYMENT AT OTHERiOCATIONS AS NECESSARY TO CORRECT SLAB FLATNESS AND LEVELNESS 2� WHERE SUBSEQUENT FINISHING OF THE MATERIAL IS REQUIRED, FLOAT TO LEVEL SURFACE. 3) APPLY PRIMER TO ALL AREAS TO RECEIVE UNDERLAYMENT; REPEAT APPLICATION IF NECESSARY TO ACHIEVE PROPER BUILD. a) MIX MATERIALS AND POUR OR PUMP AND SQUEEGEE INTO PLACE TO ACHIEVE APPROPRIATE THICKNESS. FINISH TO A SMOOTH LEVEL SURFACE WITHIN TOLERANCES SPECIFIED FOR CONCRETE FLOORS. CURE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. D. TOLERANCES: i� LEVEL SURFACES: ASTM E7155; FF 35, FL 25, OVER TEST AREA; FF 24, FL 17, MINIMUM LOCAL VALUE. 2) RAMPS AT TRANSITIONS AND SLOPES TO DRAIN: MAXIMUM SLOPE 114" PER FOOT. DIVISION 04 - MASONRY (NOT USED) DIVISION 05-METAL 054000 - COLD FORMED METAL FRAMING �. GENER4L A. SECTION INCLUDES: t) EXTERIOR LIGHTGAGE (AXIAL AND TRANSVERSE) LOAD BEARING METAL FRAMING, WITH ANCHORAGE AND BRACING. 2) STRUCTUR4L DESIGN OF SYSTEMS. e. SYSTEM DESCRIPTION �) STRUCTURALDESIGN: n) SIZE AND ARRANGE MEMBERS TO SUPPORT DEAD LOADS, AND TO RESIST LIVE LOADS INDICATED ON THE STRUCTURAL DRAWINGS, P,ND INCLUDING WIND LOADS IN ACCORDANCE WITH THE LOCAL JURISDICTIONAL REQUIREMENTS. e) DESIGN SYSTEM TO RESIST 100 PERCENT OF THE DESIGN LOAD WITH A MAXIMUM DEFLECTION OF U360. C) DESIGN SYSTEM TO ACCOMMODATE BUILDING DEFLECTION, DYNAMIC BUILDING MOVEMENT, AND TEMPERATURE VARIATIONS WITHOUT DAMAGE TO SYSTEM COMPONENTS. DESIGN SYSTEMS TO ACCOMMODATE A FLOOR DEFLECTION OF 3/41NCH. 2) CONFIGURATION: a� PROVIDE FR4MING OF DEPTH INDICATED ON THE DRAWINGS. e) WHERE STUD GAGE IS INDICATED ON THE DR4WINGS, PROVIDE STUDS OF INDICATED OR HEAVIER GAGE. C) WHERE STUD SPACING IS INDICATED ON THE DRAWINGS, PROVIDE ADDITIONAL STUDS OR CLOSER SPACWG AS NECESSARY TO MEET DESIGN REQUIREMENTS. o) IN ADDITION TO COLD FORMED METAL FRAMING INDICATED ON THE DRAWINGS, PROVIDE ADDITIONAL MEMBERS LOCATED AS NECESSARY TO ANCNOR SUPERIMPOSED LOADS. c. SUBMITTALS i) SHOP DRAWINGS: A) INDICATE TYPICAL AND SPECIAL DETAILS, INCLUDING FRAMING DETAILS, ANCHORAGE SYSTEMS, FASTENING SYSTEMS, LOADS, AND ACCESSORIES OR ITEMS REQUIRED OF OTHER WORK FOR COMPLETEINSTALLATION. B) INCLUDE DESIGN ENGINEER'S SEAL, IF REQUIRED. o. QUALITY ASSURANCE 1) USE ONLY WELDERS CERTIFIED BY AWS, ORAS OTHERWISE REQUIRED BY THE AHJ. . 2j WELDING: AWS D1.3. 3) STRUCTUR4L DESIGN: EXCEPT WHERE $IZES, SPACING, CONNECTIONS, AND SPECIAL FR4MING CONDITIONS ARE SPECIFICALLY INDICATED ON THE STRUCTURAL DRAWINGS, FRAMING SYSTEMS SHALL BE DESIGNED BY A STRUCTURAL ENGINEER LICENSED TO PRACTICE IN STATE WHERE PROJECTISLOCATED. 2. PRODUCTS n. COMPONENTS �) COLD FORMED LIGHT-GAGE STEEL FRAMING: ASTM A653; MINIMUM G60 GALVANIZED COATING. 2) FABRICATE FROM STEEL SHEET; QUALITY SQ, GRADE 50; MINIMUM 16 GAGE. 3) FINISH: G60 ZINC COATED FINISH IN ACCORDANCE WITH ASTM A653. 4) STUDS: C SHAPED SECTIONS; MINIMUM 1-5/81NCH WIDE FLANGES WITH RETURN LIR e. ACCESSORIES: �) SCREWS: ASTM C954; SELF DRILLING, SELF TAPPING; PAN HEAD; GALVANIZED OR FLUOROPOLYMER COATED STEEL. 2� SILL GASKET: CLOSED CELL POLYETHYLENE FOAM, GLASS FIBER STRIPS, OR APPROVED; CONTINUOUS ROLLS; WIDTH OF SILL PLATE. 3. EXECUTION n. INSTALL LIGHTGAGE STRUCTURAL PRAMING IN ACCORDANCE WITH ASTM C1007, UNLESS INDICATED OR SPECIFIED OTHERWISE. a. PLACE SILL GASKET UNDER RUNNERS FOR EXTERIOR PARTITIONS. PUNCTURE GASKET CLEAN AND FIT TIGHT TO PROTRUDING FOUNDATION ANCHOR BOLTS. c. UNLESS OTHERWISE INDICATED, SCREW OR WELD EACH JOINT. WELD IN ACCORDANCE WITH AWS D1.3. D. SAW OR SHEAR CUT METAL FR4MING MEMBERS . NO TORCH CUTTING PERMITTED. E. ERECT STUDS IN ONE PIECE FULL LENGTH. SPLICING AND WIRE TYING OF FRAMING COMPONENTS SHALL NOT BE USED. F. CONSTRUCT CORNERS WITH A MINIMUM OF 3 STUDS PER CORNER. c. TOLERANCES: �) PLUMB: 1/81NCH IN 10 FEEL 2) IOCATION: WITHIN 1l41NCH OF THE REQUIRED LOCATION. 3) LEVEL: 1!8 INCH IN 10 FEET. H. TOUCH-UP FIELD WELDS AND SCR4TCHED OR DAMAGED GALVANIZING IN ACCORDANCE WITH REQUIREMENTS OF ASTM A780. 055000 - METAL FABRICATIONS t GENERAL A. SECTION INCLUDES: �) STEEL FABRICATIONS INDICATED ON THE ARCHITECTURAL DRAWINGS AND NOT SPECIFIED IN OTHER SECTIONS. 2) MISCELlANEOUS ORNAMENTAL METAL FABRICATIONS, WCLUDING DECORATIVE EXPOSED STRUCTURAL ELEMENTS. e. SHOP DRAWINGS: INDICATE PROFILES, SIZES, CONNECTION ATTACHMENTS, REINFORCING, SIZES AND TYPES OF FASTENERS, FINISHES, AND ACCESSORIES. 2. PRODUCTS: n. STEEL �) STEEL PLATE, BARS, SHAPES: ASTM A36. 2) TUBES: ASTM A500 OR A501. 3) PIPE: ASTM A53, SEAMLESS, TYPE S, PLAIN END; SCHEDULE 40 UNLESS INDICATED OTHERWISE. e. STAINLESS STEEL: ASTM A167; TYPE 304. c. FASTENERS: �) AS APPROPRIATE TO THE APPLICATION; COMPATIBLE WITH MATERIALS BEING FASTENED; GALVANIZED WHERE INDICATED FOR USE IN EXTERIOR OR DAMP LOCATIONS.. 2) BOLTS AND NUTS: ASTM A307 o. FABRICATION: 1) AS INDICATED, AND IN ACCORDANCE WITH APPROVED SHOP DR4WINGS. 2) FOR ITEMS EXPOSED TO VIEW OR SUBJECT TO CONTACT, GRIND WELDS SMOOTH AND LEVEL WITH ADJACENT SURFACES; REMOVE ALL BURRS FROM CUT EDGES. 3) STAINLESS STEEL WATER HEATER PAN: FABRICATE FROM MINIMUM 24 GAGE STAINLESS STEEL; SOLDERED CORNERS; HEMMED EDGES. a) SHOP FINISHES: n) GALVANIZED: (�) CONCEALED: NOFURTHERFINISH (2) EXPOSED TO VIEW: AS INDICATED. s) UNGALVANIZED STEEL: FAGTORY PRIME PAINTED AFTER FABRICATION. c) OTHER METAL FABRICATIONS: AS DIRECTED. � i� 222 MERCHANDISE MART PLAZA, SUITE 230� CHICAGQ IL. 60654 P:312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Shee4 Suite 2531 Alvon, OH 94311 330.572.210� Fax: 330.572.2302 Wc G�/ 1..1_ Q U Z M C� z J G Q U ch � � 0 � 0 N � W m � � Z H U w O � a �,,e�°`` � di ma Qe�r,omo 0m J. p,r� � ��'< z� r : � m � �',�,6 a�s ; � � f " - . , ,. }� s". � - ; '� a,� .. � .. _,. �..,,7k` il SHEET TITLE ARCHITECTURAL SPECIFICATIONS SHEET NUMBER AS1.1 3. EXECUTION: A. INSTALL METAL FABRICATIONS IN ACCURATE LOCATIONS SHOWN. UNLESS INDICATED OTHERWISE, FABRICATIONS SHALL BE INSTALLED PLUMB AND ; LEVEL. 055023 - OVERHEAD SUPPORT FRAMING 1. GENERAL A. SECTION INCLUDES: SUPPORTS FOR CEILMG FINISHES AND FIXTURES.: s. SYSTEM DESCRIPTION �) SUPPORT PRAMWG SHALL BE STEEL UNLESS APPROVED OTHERWISE. USE PROPRIETARY CHANNEL SUPPORT SYSTEMS WITH SUPPLEMENTARY SHOP FABRICATED STEEL SECTIONS AS APPROPRIATE TO THE INSTALLATION: 2) CONFIGURATIONS SIZE MEMBERS AND SELECT ANCHORAGE SYSTEMS TO SUPPORT THE DEAD LOAD AS WELL AS LIVE OPERATIONAL LOADS; SAFETY FACTOR 2.5 BASED ON ULTIMATE STRENGTH UNDER STATIC LOAD CONDITIONS. c. SUBMITTALS t� PRODUCT LITER4TURE. z) SNOP DRAWINGS SHOW DETAILS OF FABRICATION AND INSTALLATION; WDICATE MATERIALS, DIMENSIONS, ATTACHMENTS, PROPRIETARY CHANNEL SUPPORT SYSTEM PRODUCT NUPABERS, PROVISIONS FOR WORK OF OTHER TRADES, AND OTHER PERTINENT INFORMATION AS NECESSARY TO COORDINATE THE WORK. o. STRUCTURAL DESIGN: SUPPORTS FOR OVERHEAD EQUIPMENT NOT SPECIFICALLY INDICATEDAN THE STRUCTURAL DRAWINGS SHALL BE DESIGNED BY A STRUCTURAL ENGINEER LICENSED TO PRACTICE IN THE STATE OF WASHINGTON. . 2. PRODUCTS a PROPRIETARY CHANNEL SUPPORT SYSTEMS: �) MANUFACTURER: UNISTRUT (SPOKANE, WA; 50&535-9841). 2) SYSTEM: P1000. 3) FINISN: "PERMA-GREEN" RUST INHIBITING ELECTRO-DEPOSITED ACRYLIC ENAMEL. 3. EXECUTION: n. INSTALL IN ACCORDANCE WITH THE APPROVED SHOP DRAWINGS. DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES 061000-ROUGH CARPENTRY t GENERAL k. SECTION INCLUDES �) BLOCKING, NAILERS, AND CURBING. z) PLYWOOD TERMINAL BACKBOARD s) WATER HEATER PLATFORM e. SYSTEM DESCRIPTION BACKING: WHERE CONCEALED BACKING IS INDICATED OR REQUIRED IN STEEL FRAMED WALLS, PROVIDE WOOD OR METAL BACKWG AT CONTRACTOR'S OPTION 2. PRODUCTS A. DIMENSION LUMBER: IN ACCORDANCE WITH PS 20; STAMPED AND GRADED IN ACCORDANCE WITH WWPA OR WCLB GRADING RULES. 1) MOISTURE CONTENT: KILN DRIED T019%MAXIMUM MOISTURE CONTENT, EXCEPT FOR MATERIAL WHOSE LEAST DIMENSION IS 4 INCHES THICK OR GREATER. 2) SPECIES: HEM-FIR, SPRUCE-PINE-FIR (SPF), OR DOUGLAS FIR LARCH, UNLESS INDICATED OR SPECIFIED OTHERWISE. 3) UNEXPOSED NON-STRUCTURAL WOOD FRAMING AND BLOCKING GRADED AS FOLLOWS: n} MEMBERS 2" TO 4" THICK, 2° TO 4" N/1DE: °NO 2- STRUCTUR4L LIGHT FRAMING," OR BETTER; "STUD" GRADE MAY BE USED AT STUD APPLICATIONS B) MEMBERS 2" TO 4" THICK, 5° AND WIDER: "N0. 2- STRUCTURAL JOISTS AND PLANKS," OR BETTER. B. PLYWOOD BACKING(CONCEALED) AND SHEATHING: APA RATED SHEATHING, CD GRADE; EXTERIOR; PLYWOOD, UNLESS APPROVED OTHERWISE; THICKNESSES AS INDICATED. C. TERMINAL BACKBOARDS: APA AC GRADE EXTERIOR; FIRE RETARDANT TREATED. D. FASTENERS 1) HOT-DIPPED GALVANIZED STEEL OR COPOLYMER COATED FOR EXTERIOR, HIGH HUMIDITY, AND TREATED WOOD LOCATIONS. 2) SCREWS: SELF TAPPING, COUNTERSUNK OR LOW PROFILE HEAD. E. FIRERETARDANTTREATMENT: i) FIRERETARDANTTREATALLiNTERIORCONCEALEDLUMBERAND PLYWOOD, AND OTHER WOOD AS INDICATED OR REQUIRED. 2) ALL FIRE RETARDANT TREATED WOOD MATERIALS SHALL BEAR A UL "FR-S" IABEI, OR A IABEL FROM AN APPROVED INSPECTION AGENCY CERTIFYWG THAT THE MATERIAL MEETS THE REQUIREMENTS OF AWPA C_20 TYPE AFOR LUMBER AND AWPA G27 TYPE A FOR PLYWOOD. 3) TREATED LUMBER SHALL BE KILN DRIED TO A MAXIMUM MOISTURE CONTENT OF 19%; TREATED PLYWOOD SHALL BE KILN DRIED TO A MAXIMUM MOISTURE CONTENT OF 15 PERCENL 3. EXECUTION n. BLOCKING AND NAILERS: MINIMUM 2 INCHES THICK; EXCEPT WHERE FRAMING HAS BEEN CONFIGURED OR DESIGNED TO SUPPORT RESPECTIVE COMPONENTS, INSTALL WOOD BLOCKING TO RECEIVE MECHANICAL FASTENERS FOR SUPPORT OF PLUMBING AND ELECTRICAL FIXTURES AND EQUIPMENT, CABINETS, DOOR STOP PLATES, WOOD BASE, WAINSCOTS, COAT HOOKS, TOILET AND BATH ACCESSORIES, AND ALL OTHER WALL AND CEILING MOUNTED COMPONENTS. e. SCREW FASTEN WOOD COMPONENTS TO METAL FRAMING AND SUPPORT ELEMENTS. c. FORATTACHMENT OF PLYWOOD BACKING, KERF PLYWOOD 1/4"(3!8° MAXIMUM IF REQUIRED FOR HEAVY GAGE STUDS) TO RECEIVE FLANGE RETURN (OR CRIMP THE RETURN CLOSED); PROVIDE SUPPLEMENTARY SHEET METAL ANGLE ATTACHED TO BACK 9F STUD WHERE NECESSARY TO SUPPORT BACKWG. SCREWS INTO EDGE OF PLYWOOD ARE UNACCEPTABLE. 062213 - INTERIOR FINISH CARPENTRY t GENERAL A. SECTION INCLUDES: �) STANDINGANDRUNNINGTRIM. z) EXPOSED FRAMING 3) INSTALLATION OF OWNER FURNISHED WOODWORK e. SHOP DRAWINGS: FOR ITEMS FURNISHED UNDER THIS CONTRACT, INDICATE PAATERIALS, COMPONENTS, PROFILES AND CONFIGURATIONS, DIMENSIONS, FASTENWG METHODS, JOINTING DETAILS, COLORS AND FINISHES, AND ACCESSORIES. 2. PRODUCTS A. CONCEALED FRAMING LUMBER: PINE, FIR, HEMLOCK, OR OTHER SPECIES AS APPROVED; MAXIMUM MOISTURE CONTENT 10 PERCENT. e. EXPOSED LUMBER FOR OPAQUE FINISH: ALDER, POPLAR OR SIMILAR APPROVED HARDWOOD' AWS CUSTOM GRADE. C. EXPOSED FRAMWG LUMBER: PS20; SELECT B&BTR. o. PREFABRICATED TRIM: AS SCHEDULED; FURNISHED BY OWNER UNLESS OTHERWISE SCHEDULED. E. TAMBOUR: AS SCHEDULED. F. CEDAR: FURNISHED BY THE OWNER 1) MDO (SMOOTH) PLYWOOD: APA RATED, GROUP 1, B-C OR BETTER; MDO FACE. G. MEDIUM DENSITY FIBERBOARD (MDF): 1� ANS! A2082 CLASS MD (PAEDIUM DENSITYj. 2} MOISTURE RESISTANT MDF: SIERRA PWE LTD. (800 676 3339) "MEDEX"; OR APPROVED; ANSI A208.2 CLASS MD. 3) FREE FROM ADDED UREA-FORMALDEHYDE. H. FASTENERS �} JOIST HANGERS: AS INDICATED. 2) LAG BOLTS: 3/8" X LENGTNS AS APPROPRIATE TO THE APPLICATION; UNFINISHED. 3) MISCELLANEOUS HARDWARE: FURNISH NAILS, WASHERSAND OTHER FASTENERS AS NECESSARY TO COMPLETE THE WORK. l. FABRICATION �) SHOP FABRICATE ALL TRIM TO THE SHAPES INDICATED. 2) UNLESS OTHERWISE SCHEDULED, STANDING AND RUNNING TRIM T0 RECEIVE OPAQUE FINISH MAY BE FABRICATED FROM MDF OR LUMBER AS SPECIFIED. 3) SHOP FIT AND ASSEMBLE TO THE GREATEST EXTENT PRACTICAL. a) BACK OR KERFLUT ALL TRIM GREATER THAN 21NCH IN WIDTH, EXCEPT TERMINATE BEFORE EXPOSED ENDS. 3. EXECUTION A. INSTALLATION t) JOINTING: MAKE ALL JOINTS TO CONCEAL SHRINKAGE; MITER ALL EXTERIOR CORNERS; COPE ALL INTERIOR CORNERS, MITER OR SCARF ALL END-TO-END JOINTS; INSTALL ALL TRIM PIECES AS LONG AS , POSSIBLE, JOINTING ONLY WHERE SOLID SUPPORT IS OBTAINED. MAKE NO JOINTS CLOSER THAN 4 FEET TO CORNERS. z� LENGTHS OF MATERIAL: USE RANDOM LENGTHS AND SHOW TYPICAL JOINT LOCATIONS ON SHOP DRAWINGS. THE MINIMUM LENGTH SHALL BE 8 FEET, EXCEPT WHERE SHORT LENGTHS ARE REQUIRED BY INSTALLATION CONDITIONS. 3} FASTENING: A) INSTALL ALL ITEMS STRAIGHT, TRUE, LEVEL, PLUMB, AND FIRMLY ANCHORED IN PLACE; WHERE BLOCKING OR BACKING IS REQUIRED, COORDINATE AS NECESSARY WITH OTHER TRADES TO ENSURE PLACEMENT OF ALL REQUIRED BACKING AND BLOCKWG IN A TIMELY MANNER. e) FASTEN TRIM WITH FINISH NAILS OR TRIM HEAD SCREWS OF PROPER DIMENSION TO HOLD THE MEMBER PIRMLY IN PLACE WITHOUT SPLITTING THE WOOD. c� ON EXPOSED FINISH WORK, SET ALL NAILS AND SCREWS. o) ALIGN EXPOSED FASTENERS FOR UNIFORM PATTERN; RANDOM OR "SHOTGUN° PATTERNS WILL NOT BE ACCEPTED. a. PUTTY FILL ALL EXPOSED FASTENER HOLES AND LEVEL WITH SURFACE. FOR TRIM INDICATED FOR TRANSPARENT FINISH; USE COLOR MATCHED PUTTY; SEQUENCE WITH FINISHING TO AVOID SOWENT STAINING. 064100-ARCHITECTURALCASEWORK t GENERAL n. SECTION INCLUDES �) INSTALLATION OF OWNER FURNISHED CASEWORK AND SHELVING. 2j COORDINATION WITH OWNER FOR WSTALLATION OF CASEWORK BY THE OWNER AND/OR OWNER'S VENDOR. e. SHOP DRAWINGS: INDICATE LOCATIONS OF WALL MOUNTED CASEWORK AND BLOCKING. c. OBTAIN TEMPLATES, SHOP DRAWINGS, AND INSTALLATION INSTRUCTIONS FROM OWNER'S VENDOR(S), AS NECESSARY TO FACILITATE PROPER WSTALLATION. 2. PRODUCTS A. FURNISH WOOD AND STEEL BLOCKING AS SPECIFIED IN SECTION 092200. e. COORDINATE WITH OTHER TRADES AS NECESSARY FOR PROPER INCORPORATION OF UTILITIES AND INTERFACE WITH FINISHES. 3. EXECUTION a. INSTALL CASEWORKAS DIRECTED. s. COORDINATE WITH OWNER TO ACCOMMODATE CASEWORK INSTALLATION, AS NECESSARY. DIVISION 07-THERMALANDMOISTUREPROTECTION 070183 - REPLACEMENT FIREPROOFING t GENERAL n. SECTION INCLUDES: �) SURFACE PREPARATION AND COORDINATION WORK FOR PATCHING OF EXISTING AND INCIDENTAL NEW FIREPROOFING WORK. 2) FIREPROOFING MATERIALS. 3) SEALING OF EXISTING FIREPROOFING INDICATED TO REMAIN EXPOSED IN THE FINISHED WORK. B. SUBMITTALS: MANUFACTURERS' DATA; INCLUDE INSTRUCTIONS FOR PROPERAPPLICATION OF SPRAYED REPLACEMENT FIREPROOFING. c. QUALITYASSURANCE t) fIREPR00FING WORK SHALL BE PERFORMED BY A FIRM ACCEPTABLE TO THE SPR4YED REPLACEMENT FIREPROOFING MATERIALS MANUFACTURER. 2� PRODUCTS, EXECUTION AND FIREPROOFWG THICKNESSES SHALL CONFORM TO THE APPLICABLE CODE REQUIREMENTS FOR THE FIRE-RESISTANCE RATINGS CALLED FOR. 2. PRODUCTS a. FIREPROOFING MATERIAL: FURNISH ONE IF THE FOLLOWING,AS APPROPRIATE FOR PATCHING EXISTING FIREPROOFING. 1) CEMENTITIOUS: GRACE CONSTRUCTION PRODUCTS "MONOKOTE MK-6," ISOLATEK INTERNATIONAL "CAFCO 300," OR APPROVED CEMENTITIOUS FIREPROOFING. 2) MINERAL FIBER: ISOLATEK WTERNATIONAL "CAPCO BLAZE SHIELD II" SPRAY APPLIED FIREPROOFING MATERIAL. B. QUALIFICATIONS: �) REPLACEMENT FIREPROOFING MATERIAL SHALL HAVE BEEN TESTED AND REPORTED BY UL IN ACCORDANCE WITH PROCEDURES OF ASTM E119. 2) THE FIREPROOFING PRODUCT SHALL BE TESTED IN ACCORDANCE WITH ASTM STANDARD G_21_75, AND SHALL SHOW RESISTANCE TO MOLD GROWTH. MOLD INHIBITOR SHALL BE ADDED BY THE MANUFACTURER. a) SURPACE BURNING CHARACTERISTICS; IN ACCORDANCE WITH ASTM E84: e) FLAME SPREAD: 0 c) SMOKE DEVELOPMENT: 0 a EXECUTION �� PREPARATION A� VERIFY THAT ALL SURFACES TO RECEIVE SPRAYED REPLACEMENT FIREPROOPING ARE FREE OF FOREIGN SUBSTANCES WHICH MAY IMPAIR PROPER ADHESION OF THE FIREPROOFWG TO THE SUBSTRATE. e) VERIFY THAT WORK OF OTHER TRADES HAS PROGRESSED TO THE POINT WHERE REPLACEMENT FIREPROOFING INSTALLATION CAN BEGIN. z) APPLICATION: ALL PATCHWG AND REPAIRING OF SPRAYED REPLACEMENT FIREPROOFING DUE TO REMOVAL AS NECESSARY TO ACCOMMODATE NEW CONSTRUCTION, AND DAMAGE BY THE OTHER TRADES, SHALL BE PERFORMED UNDER THIS SECTION. 072117 - FIBROUS BUILDING INSULATION �. GENERAL A. SECTION INCLUDES: �) THERMAL BATTAND BLANKET INSULATION. z) VAPORRETARDER. e. PRODUCT DATA: SUBMIT FOR EAGH TYPE OF WSULATION AND VAPOR RETARDER. z. PRODUCTS n. FACED BATT AND BLANKET INSULATION: �) JOHNS MANVILLE CORP. "FSIt25,° OWENS-CORNING FIBERGLAS CORP. °FLAME SPREAD 25," KNAUF INSULATION (800-825-4434) "ECOBATT FSK-FOIL FACED," OR APPROVED. 2) ASTM C665, TYPE III, CLASS A; PREFORMED FORMALDEHYDE-FREE GLASS FIBER ROLL WITH FOIL SCRIM KRAFT FACE; FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPED OF 50 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. 3) MINIMUM 20 PERCENT CALCULATED (BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER) RECYCLED CONTENT. a) THICKNESS AS NECESSARY TO ACHIEVE MINIMUM R-13 THERMAL RESISTANCE. s. UNFACED BATT AND BLANKET INSULATION: �) JOHNS MANVILLE CORP. "UNFACED FORMALDEHYDE-FREE THERMAL AND ACOUSTICAL FIBER GLASS INSULATION;' KNAUF INSULATION (800-825-4434) "ECOBATT,° OR APPROVED. 2) ASTM C665, TYPE I; PREFORMED UNFACED GLASS FIBER BATTS; FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPED OF 50 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. 3) UNFACED FORMALDEHYDE-FREE GLASS FIBER COMMERCIAL INSULATION; OVERSIZE WIDTHS FOR FRICTION-FIT BETWEEN METAL FRAMING MEMBERS; MINIMUM 20 PERCENT CALCULATED (BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER) RECYCLED CONTENL 4) THICKNESS AS INDICATED ON THE DRAWINGS. c. VAPOR RETARDER: CERTAINTEED CORPORATION (VALLEY FORGE PA; 610_341_7000; 80�_233_8990) "MEMBRAIN"; 2 MIL POLYAMIDE FILM; FLAME SPREAD OF 50 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. D. ACCESSORIES �) TAPE: MATCH VAPOR RETARDER; 2 INCH WIDTH. 2) FURNISH OTHER ACCESSORIES, NOT SPECIFICALLY DESCRIBED, BUT REQUIRED FOR SECURE AND TIGHT INSTALLATION OF INSULATION WITH COMPLETE INSULATION FILL WITHW CAVITIES, AND CONTINUOUS VAPOR RETARDER. E. ADHESIVE: �) TYPE RECOMMENDED BY INSULATION MANUFACTURER FOR APPLICATION; CAMPATIBLE WITH INSULATION AND SUBSTRATE. 2) TOXICITYtIEQ: COMPLY WITH APPLICABLE REGULATIONS REGARDING TOXIC AND HAZARDOUS MATERIALS, GS-36 FOR COMMERCIAL ADHESIVE AND SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. s. EXECUTION A. INSTALL INSULATION WITHOUT GAPS OR VOIDS. B. TRIM INSULATION NEATLY TO FIT SPACES. USE BATTS FREE OF DAMAGE. C. WALL INSULATION AND VAPOR RETARDER 1) AT METAL STUD FRAMING, INSTALL UNFACED BATT WITH EDGES TIGHTLY SET INTO THE STUD CHANNELS FOR A FRICTION FIT. PROVIDE ADDITIONAL SUPPORTS AS NECESSARY TO PREVENT SLIDING OF BATTS IN THE STUD CAVITY. 2) SEPAR4TE VAPOR BARRIER INSTALLATION: n) INSTALL SEPARATE VAPOR BARRIER OVER UNFACED INSULATION. B) INSTALL VAPOR BARRIER TOWARD WARM SIDE OF BUILDING SPACES C) VAPOR BARRIER SHALL BE CONTINUOUS. o� AT LIGHTGAGE SUPPORT FRAMING, SECURE TO STUDS WITH DOUBLE STICK TAPE OR SPRAY ADHESIVE. E) LAP JOINTS IN VAPOR BARRIER 2 INCHES, EXCEPT PROVIDE TAPE SEALED JOINTS AT LOCATIONS WHERE VAPOR BARRIER WILL REMAIN EXPOSED IN THE FINISHED WORK. F) TAPE SEAL VAPOR BARRIER TO ADJACENT CONSTRUCTION AT PERIMETER EDGES. c) TAPE AND SEAL TEARS OR CUTS IN VAPOR BARRIER. D. CEILING INSULATION: INSTALL FACED BATTS OVER CEILING WITH ENDS AND EDGES TIGHTLY Bl1TTED WITHOUT GAPS. SECURE WITH ADHESIVE AS APPROPRIATE. E. SITE ENVIRONMENTAL PROCEDURES: 1) WASTE MANAGEMENT: AS SPECIFIED IN SECTION 018113 AND AS FOLLOWS: z) COORDINATE WITH MANUFACTURER FORTAKE-BACK PROGRAM. SET ASIDE SCRAP TO BE RETURNED TO MANUFACTURER FOR RECYCLING INTO NEW PRODUCT. �78413 - PENETRATION FIRESTOPPING 1. GENERAL a. SECTION INCLUDES: FIRESTOPPING SYSTEMS FOR SEALING PENETRATIONS THROUGH FIRE-RATED CONSTRUCTION. B. PERFORMANCE REQUIREMENTS 1) EACH FIRESTOPPING SYSTEM SHALL BE SELECTED TO MAINTAIN FIRE RATING OF THE ASSEMBLY IN WHICH IT IS USED. 2) WHERE PENETRATION FIRESTOPPING IS USED TO SEAL PENETRATIONS THROUGH FLOORS WITH WATERPROOF MEMBRANES, SYSTEM SNALL BE SELECTED FOR COMPATIBILITY WITH MEMBRANE MATERIAL. 3� PROVIDE PRODUCTS THAT UPON CURING, DO NOT RE-EMULSIFY, DISSOLVE, LEACH, BREAKDOWN OR OTHERWISE DETERIORATE OVER TIME FROM EXPOSURE TO ATMOSPHERIC MOISTURE, SWEATING PIPES, PONDING WATER OR OTHER FORMS OF MOISTURE CHAR4CTERISTIC DUWNG AND AFTER CONSTRUCTION. a) PROVIDE FIRESTOP SEA�ANTS SUFFICIENTLY FLEXIBLE TO ACCOMMODATE MOTION SUCH AS PIPE VIBRATION, WATER HAMMER, THERMAL EXPANSION AND OTHER NORMAL BUILDING MOVEMENT WITHOUT DAMAGE TO THE SEAL. 5) PIPE INSULATION SHALL NOT BE REMOVED, CUT AWAY OR OTHERWISE INTERRUPTED THROUGH WALL OR FLOOR OPENINGS. PROVIDE PRODUCTS APPROPRIATELY TESTED FOR THE THICKNESS AND TYPE OF INSULATION UTILIZED. s) OPENINGS WITHIN WALLS AND FLOORS DESIGNED TO ACCOMMODATE VOICE, DATA AND VIDEO CABLING SHALL BE PROVIDED WITH RE-ENTERABLE PRODUCTS SPECIFICALLY DESIGNED 0 F R RETROFIT. �) PENETRATIONS THROUGH FIRE-RESISTANCE ft4TED FLOOR-CEILING ASSEMBLIES CONTAINED WITHIN CHASE WALL ASSEMBLIES SHALL BE PROTECTED WITH PRODUCTS TESTED BY BEING FULIY EXPOSED TO THE FIRE OUTSIDE OF THE CHASE WALL c. QUALITYASSURANCE �) CODE VERIFICATION: PRIOR TO INSTALLATION OF FIRE STOPPING SYSTEMS OBTAIN APPROVAL FROM THE JURISDICTIONAL CODE AUTHORITIES FOR THE FIRE STOPPING SYSTEMS AND APPLICATIONS PROPOSED. 2) FIRESTOPPING: TESTED IN ACCORDANCE WITH ASTM E119, OR UL 1479 TO MEET THE HOURLY FIRE RATINGS OF THE CONSTRUCTION BEING SEALED. PROVIDE F RATED ASSEMBLIES, EXCEPT WHERE T RATED ASSEMBLIES ARE REQUIRED BY THE CODE AUTHOPoTY. z. PRODUCTS A. SYSTEMS MEETING THE REQUIREMENTS SPECIFIED AND SUITABLE FOR THE CONDITIONS INDICATED AS MANUFACTURED BY ONE OR MORE OF THE FOLLOWING. �) METACAULK. 2) TREMCOINQ 3) HILTI USA. a) GRACE CONSTRUCTION PRODUCTS. 5� SPECIFIED TECHNOLOGIES, INC. s� 3M. B. ELECTRICAL BOX INSERTS: �) MANUFACTURER: RECTORSEAL (HOUSTON TX; 713_263_8001; 800_231_3345). 2) FIRE RATED PADS: "BIOFIRESHIELD LECTRA-STOP'y 1/41NCH THICK INTUMESCENT PADS; SIZED TO FIT ELECTRICAL BOXES; CLASSIFIED BY UL; MINIMUM 2 HOUR RATING. 3. EXECUTION n. PROVIDE FIRESTOPPWGAT MECHANICAL, ELECTRICAL, AND PLUPABING PENETRATIONS THROUGH FIRE RATED FLOORS, WALLS, AND CEILINGS. e. WHERE FIRESTOPPING IS USED TO SEAL AROUND PENETR4TIONS THROUGH WATERPROOF MEMBRANES, INSTALLTO MAINTAIN INTEGRITY OF WATERPROOF BARRIER. C. FOR SEALING ELECTRICAL BOXES, COORDINATE INSTALLATION WITH DIVISION 26. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION AND INSTALLATION. INSTALL IN LOCATIONS AS REQUIRED BY CODE FOR PROTECTION OF OPENINGS THROUGH FIRE R4TED PARTITIONS. o. FILL OPEN HOLES WHICH REMAIN AFTER REMOVAL OF EXISTING MECHANICAL, ELECTWCAL, AND PLUMBING COMPONENTS. PATCH AND REPAIR HOLES AS NECESSARY TO MATCH THE ADJACENT CONSTRUCTION AND TO MAINTAIN THE FIRE RATING OF THE ASSEMBLIES. FIRESTOPPING SYSTEMS MAY BE USED TO FILL HOLES WHICH WILL BE CONCEALED IN THE FINISH CONSTRUCTION. 079200 - JOINT SEALANTS t. GENERAL: A. SECTION INCLUDES: SEALANTS FOR INSTALLATION AT INTERIOR NON-MOVING JOINTS, CER4MIC TILE EXPANSION JOINTS, AND AS NECESSARY TO SEAL JOINTS AROUND CASEWORK AND PLUMBWG FIXTURES. 2. PRODUCTS A. SEALANTS: �) TYPE PTNS: ASTM C920, TYPE M, GRADE NS, CLASS 25; PECORA "DYNATRED," TREMCO "HPL," OR APPROVED; STANDARD COLOR AS SELECTED FROM THE MANUFACTURER'S COMPLETE LINE OF PRE-FORMULATED COLORS. 2) TYPE A: ASTM C834� TREMCO "ACRYLIC LATEX CAULK," PECORA "AG20+SILICONE," SONNEBORN "SONOLAC," OR APPROVED; STANDARD COLORS TO MATCH ADJACENT CONSTRUCTION. 3) TYPE S- NEUTRAL GURE SILICONE SEALANT: DOW CORNING, "790 SILICONE BUILDING SEALANT," "795 SILICONE STRUCTURAL GLAZWG AND WEATHERPROOFIN� SEALANT," OR "CONTRACTORS WEATHERPROOFING SEALANT"; PECORA "890 FTS SILICONE;° OR TREMCO INC. "SPECTREM 3." 4) TYPE SM: MILDEW RESISTANT SILICONE SEALANT: USDA APPROVED; DOW CORNWG "786,° GE "SANITARY SCS1700," OR APPROVED; TRANSLUCENT OR WHITE, AS SCHEDULED. e. PRIMER: AS RECOMMENDED BY RESPECTIVE MANUFACTURERS FOR EACH APPLICATION. C. BACKER ROD: CLOSED OR OPEN CELL FOAM AS RECOMMENDED BY THE SEALANT MANUFACTURER FOR THE APPLICATION; ROUND PROFILE; THICKNESS APPROXIMATELY 130 PERCENT OF JOINT WIDTH. 3. EXECUTION: A. PERFORM WORK IN ACCORDANCE WITH ASTM C1193, UNLESS SPECIFIED OTHERWISE OR RECOMMENDED OTHERWISE BY THE SEALANT MANUFACTURER. a. TOOLING: TOOL JOINTS CONCAVE, UNLESS INDICATED OR SPECIFIED OTHERWISE. FINISH FREE OF AIR POCKETS, FOREIGN EMBEDDED MATTER, RIDGES, AND SAGS. C. SCHEDULE: �) TYPE A: PROVIDE AT INTERIOR JOINTS, UNLESS SPECIFIED OTHERWISE. z) TYPE PTNS: INSTALL IN FLOOR AND WALL TILE EXPANSION JOINTS, FULL DEPTH WITHOUT BACKER ROD; COLOR MATCHED TO GROUT IN TILE LOCATIONS, AS SELECTED BY THE ARCHITECT FOR OTHER LOCATIONS.. 3) TYPE S: PROVIDE AT EXTERIOR NON-TRAFFIC JOINTS; BLACK COLOR AT ALUMINUM FRAMING PEPoMETERS; AS DIRECTED AT OTHER LOCATIONS. a) TYPE SM: PROVIDE AT JOINTS BETWEEN WALLS, CAUNTERS OR FLOORS AND PLUMBING FIXTURES OR TOILET ACCESSORIES, AND AT COUNTER TO WALL JOINTS 4VHERE PLUMBING FIXTURES ARE INSTALLED IN THE COUNTER VNiERE SEALANT IS REQUIRED OR WDICATED. USE WHITE AGAINST WHITE PLUMBING FIXTURES; TRANSLUCENT FOR ALL OTHER APPLICATIONS. DIVISION 08-OPENINGS 081200- HOLLOW METAL DOORAND FRAME 1. GENERAL A. SECTION INCLUDES: ROLLED STEEL DOOR AND FR4ME 2. PRODUCTS A. INTERIOR DOORS: t) FACE SHEET MATERIAL: COLD-ROLLED STEEL, A 1008, 18 GAGE (0.042 WCH). 2) RECYCLED CONTENT: MINIMUM 35 PERCENT BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER RECYCLED CONTENL 3) CORE: STIFFENED, AND SOUND DEADENED WITH IMPREGNATED KRAFT HONEYCOMB CORE COMPLETELY FILLING THE INS IDE OF THE DOORS AND LAMINATED TO INSIDE FACES OF BOTH PANELS. a) DOOR HARDWARE REINFORCEMENTS: A) HINGE REINFORCEMENTS FOR FULL MORTISE HINGES: MINIMUM 7 GAGE. B) LOCK REINFORCEMENTS: MINIMUM 16 GAGE c) CLOSER REINFORCEMENTS: MINIMUM 14 GAGE, 201NCHES LONG. 5) FABRICATION: n) IN ACCORDANCE WITH ASNI A250.8; SEAMLESS; WELDED AND/OR EPDXY FILLED AT FABRICATOR'S OPTION; GRIND SMOOTH. B) BEVEL DOOR LATCH EDGES 1/8 INCH IN 2 INCHES. C) CUT MORTISES FOR BUTTS USING APPROPRIATE TEMPLATES; UNIVERSAL NON-HANDED PREPARATION OF DOORS IS NOT ACCEPTABLE. INSTALL REINFORCEMENTS, WELDED IN PLACE. D) REINFORCE TOP AND BOTTOM OF DOORS WITH 14 GAGE CHANNELS, WELDED TO BOTH FACE PANELS. B. FRAME t) ANSI A250.8; DOUBLE EQUAL RABBET, UNLESS INDICATED OTHERWISE. 2) MATERIAL: COLD-ROLLED STEEL, ASTM A1008; MINIMUM 16 GAGE (.053 WCH) s) ACCESSORIES: FURNISH NECESSARY ANCHORS FOR JAMBS, HEADS, AND SILLS OF ASSEMBLIES. a� FRAME HARDWARE REINFORCEMENTS A) MORTISE HINGE REINFORCEMENT: MINIMUM 7 GAGE: FURNISH HIGH FREQUENCY HINGE REINFORCEMENT FOR TOP HINGE ON ALL EXTERIOR, CROSS CORRIDOR, AND STAIRWELL FRAMES, IN ACCORDANCE WITH SDI 111_H. 6) STRIKE REINFORCEMENT: MINIMUM 16 GAGE. c) CLOSERREINFORCEMENT:MINIMUMI4GAGE. 5) FABRICATION n) CUT MORTISES FOR BUTTS STRIKES AND OTHER HARDWARE. PROJECTION WELD HINGE AND STRIKE REINFORCEMENTS TO THE DOOR FR4ME. PROVIDE ADEQUATE REINFORCEMENTS FOR OTHER HARDWARE AS REQUIRED. e) FRAMES SHALL BE SHOP ASSEMBLED; CONTINUOUS FACE WELD JOINT BETWEEN THE HEAD AND JAMB FACES. c) GRIND AND FINISH SMOOTH FACE JOINTS WITH NO VISIBLE FACE SEAMS. C. FINISH: MANUFACTURER'S STANDARD RUST INHIBITIVE DIRECT TO METAL PRIMER. 1) METAL DOORS A} MANUFACTURE'S PRIMER B) G.C. TO PAINT IN FIELD PER DOOR SCHEDULE ON A2.0, 2 COATS, OR AS MANY AS REQUIRED FOR FULL COVERAGE. 2) WOOD DOORS 1) ONE COAT OF THE ST-02 STAIN. 2) ONE COAT OF THE SHER-WOOD KEMA AQUA 60 DEGREE SELF-SEAL AND TOP COAT {SHERWIN WILLIAMS ITEM #M64WXC6146). 3) LIGHT SAND / SCUFF (WIPE CIEAN). 4) ONE LAST COAT OF SHER-WOOD KEMA AQUA 60 DEGREE SELF-SEAL AND TOP COAT (SHERWIN WILLIAMS ITEM #iFA64WXC6146). o. EXECUTION: �) INSTALL FRAMES IN ACCORDANCE WITH ANSI A250.11 z) DOOR INSTALLATION IS SPECIFIED IN SECTION 087103. 081433 - STILE AND RAIL WOOD DOORS �. GENERAL A. SECTION INCLUDES: INSTAILATION OF STILE AND RAIL WOOD DOORS AS SCHEDULED. a. SUBMITTALS: REQUIRE AS NECESSARY TO COORDINATE THE WORK. 2. PRODUCTS n. STILE AND RAIL TYPE DOORS: FURNISHED BY THE OWNER 3. EXECUTION A INSTALLATION: SPECIFIED W SECTION 087103. 0844113 - ALUMINUM FRAMED ENTRANCES AND STOREFRONTS t. GENERAL n. SECTION INCLUDES: �) EXTERIORANDINTERIORSTICKFRAMEDALUMINUMSTOREFRONT SYSTEMS. 2) ALUMINUM AND GLASS ENTRANCES. s. PROFILES: FRAMING MEMBER PROFILES, AS INDICATED IN THE DRAWINGS, INDICATE PROPORTIONS AND INTENT. MINOR VARIATIONS IN PROFILES, ASSEMBLIES, AND CONNECTIONS WILL BE ACCEPTED, PROVIDED THAT, IN THE OPINION OF THE ARCHITECT, THEY DO NOT SUBSTANTIALLY ALTER THE INTENDED APPEARANCE. c. SUBMITTALS �) SHOP DRAWINGS: INCLUDE WALL OPENING DIMENSIONS, COMPONENT DIMENSIONS, TOLERANCES REQUIRED, ANCHOR4GES AND FASTENERS, RELATIONSHIP TO ADJACENT CONSTRUCTION, THRESHOLD CONFIGURATIONS, INSTALLATION DETAILS, FLASHINGS, AND SEALANT LOCATIONS. 2) SAMPLES: SUBMIT THREE SAMPLES OF A TYPICAL EXTRUSION FINISHED WITH SYSTEM AND COLOR PROPOSED FOR THE FINISHED WORK;121NCH MINIMUM LENGTH. o. GUARANTEEAND WARRANTY �) MANUFACTURER'S WARRANTY: 3-YEAR WRITTEN WARRANTIES EXECUTED TO THE OWNER, FROM THE MANUFACTURERS OF THE STOREFRONTAND ALUMINUM WINDOW SYSTEMS, AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. 2) INSTALLER'S GUARANTEE: 3_YEAR WRITTEN GUARANTEE AGAINST DEFECTSININSTALLATION. 2. PRODUCTS a. EXISTING SYSTEMS: WHERE FRAMING SYSTEMS ARE INDICATED FOR RECONFIGUR4TION OR EXTENSION OF EXISTING, MATCH EXISTING. e. NEW FRAMING SYSTEMS: ONE OF THE FOLLOWING, OR APPROVED. FURNISH SCREW-SPLINE, SHEAR BLOCK OR STICK ASSEMBLY AT CONTRACTOR'S OPTION. t) KAWNEER NORTH AMERICA n) EXTERIOR: TRIFAB VERSAGLAZE 451T; 2" X 41/2" SECTION; THERMAL BREAK DESIGN; CENTER GLAZED. e) INTERIOR: TRIFAB 400; 1-3l4"X4" SECTION, CENTER GLAZED. 2) ARCADIA. A) EXTERIOR: AG451T; 2" X 4-1/2" SECTION; THERMAL BREAK DESIGN; CENTER GLAZED. B) INTERIOR: A400;1-3/4"X4" SECTION, CENTER GLAZED. 3) OLDCASTLE BUILDINGENVELOPE. a) EXTERIOR: SERIES 3000 THERMAL MULTIPLANE - CENTER SET; 2" X 41/2" SECTION; THERMAL BREAK DESIGN; CENTER GLAZED. s) INTERIOR: FG-1000;1-3l4"X4" SECTION, CENTER GLAZED. a) CRLIUSALUMINUM. a) EXTERIOR: IT451; 2" X 41/2" SECTION; THERMAL BREAK DESIGN; CENTER GLAZED. e) INTERIOR: SERIES 400; t-3l4"X4" SECTION, CENTER GLAZED. C. ENTRY DOORS: 1) EXTERIOR: HEAVY DUTY MEDIUM STILE; 10 INCH NOMINAL BOTTOM RAIL; STOPS CONFIGURED FOR 1 INCH INSULATING UNITS; ONE OF THE FOLLOWING, OR APPROVED. A� KAWNEER NORTH AMERICA "350 HEAW WALL ENTRANCE." e) ARCADIA "MS362 HD HEAVY DUTY MEDIUM STILE ENTRANCE DOOR." C) OLDCASTLE BUILDINGENVELOPE "RUGGED MEDIUM STILE." o) CRUUS ALUMINUM °SERIES 800 DUR4FRONT" 2) INTERIOR: NARROW STILE;10 INCH NOMINAL BOTTOM R41L; STOPS CONFIGURED FOR 1/41NCH GLASS; ONE OF THE FOLLOWING, OR APPROVED. a) KAWNEER NORTH AMERICA "190 STANDARD ENTR4NCE." B) ARCADIA "NS212 SERIES NARROW STILE ENTRANCE DOOR." c) OLDCASTLE BUILDINGENVELOPE °NS-212 STANDARD DUTY NARROW STILE:' o) CRIJUS ALUMINUM "SERIES 250 ENTR4NCE DOORS:' 3) ACCESSORIES: n) FURNISH INSIDE MOUNT COMPENSATION HEAD CHANNELS. e) TRANSOM DECAL: ("THIS DOORTO REMAIN UNLOCKED DURING BUSINESS HOURS"J c) FURNISH SILLS, FASTENERS, ALUMINUM FLASHINGS, WATER DIVERTERS, SPACERS, GASKETS, SEALANTS, AND ADAPTERS AS NECESSARY FOR A COMPLETE iNSTALLATION. 4) DOOR HARDWARE: n) WEATHERSTRIPPING: MANUFACTURER'S STANDARD POLY PILE IN DOOR AND/OR FRAME. B) OTHER OPERATING HP,RDWARE: AS SCHEDULED ON THE DRAWINGS. o. MATERIALS �) EXTRUDEDALUMINUM: ANSI/ASTMB221;6063-T5ALLOYANDTEMPER. 2) SHEET ALUMINUM: ASTM B209, MINIMUM .019 WCH THICKNESS FOR FLASHINGS, MINIMUM .0621NCH THICK FOR BRAKE FORMED TRIM APPLICATIONS. 3) GLAZING: FURNISHED UNDER SECTION 088000. PROVIDE SHOP GLAZED UNITS AT CONTRACTOR'S OPTION. E. FINISH: COLORANODIZED: AAMAAA-M12C22A44;ARCHITECTUR4LCLASSI, ETCHED, MEDIUM MATfE, COLORED ANODIC COATING, 07 MIL THICKNESS; DARK BRONZE ANODIZED, UNLESS OTHERWISE DIRECTED OR REQUIRED TO MATCH EXISTING. 3. EXECUTION n. INSTALL FRAMING IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. s. INSTALL SILL PAN IN ROUGH OPENING WITH END DAMS TIGHT TO THE JAMB FRAMING MEMBERS. PROVIDE SOLID BLOCKING AND ENSURE THAT THE SILL PAN IS SLOPED TO DRAIN. COORDINATE INSTALLATION TO ACCOMMODATE INSTALLATION OF FLEXIBLE FLASHING AND BUILDING PAPER ELEMENTS FLASHED TO WEATHER. C. WHERE COMPENSATING HEAD CNANNELS ARE USED, SCREW CHANNELS TO STRUCTURE WITH CENTER OF CHANNEL FIXED AND OTHER FASTENERS THROUGH SLOTTED HOLES. D. SCREW ATTACH END DAMS TO SUBSILL ENDS; SEAL JOINTS BETWEEN DAM AND SUBSILL. FASTEN THE SUB-SILL SECURELY INTO THE OPENINGS. CAP SEAL TOPS OF FASTENERS. E. COORDINATE INSTALLATION OF DOORS AND HARDWARE, AS SPECIFIED IN SECTION 08730L 087103 - DOOR HARDWARE AND INSTALLATION t GENERAL a. SECTION INCLUDES: �) CONTRACTOR-FURNISHED HARDWARE FORSWWGING DOORS (EXCEPT AS SPECIFIED AS PART OF THE DOOR PACKAGE). 2) DOORAND HARDWARE INSTALLATION. e. SUBMITTALS: SUBMIT THE FOLLOWING FOR HARDWARE TO BE FURNISHED UNDER THIS CONTRACL t) PRODUCT DATA 2) HARDWARE SCHEDULE: 4 COPIES WITH DESCRIPTION OF EACH HARDWARE GROUP. INDICATE THE FOLLOWING n) TYPE, STYLE, FUNCTION, SIZE, QUANTITY AND FINISH OF HARDWARE ITEMS. a) NAME, PART NUMBERAND MANUFACTURE OF EACH ITEM. C) FASTENINGSANDOTHERPERTINENTINFORMATION. D) EXPLANATION OF ABBREVIATIONS, SYMBOLS AND CODES CONTAINED IN SCHEDULE. E) DOOR AND FR4ME SIZES, MATERIAIS AND DEGREES OF SWING. 3) WIRING/RISER DIAGRAMS AS APPROPRIATE TO THE WORK. c. INSTALLER QUALIFICATIONS: INSTALLER: COMPANY WITH QUALIFIED PERSONNEL, WITH NOT IESS THAN 3 YEARS EXPERIENCE IN INSTALLATION OF WORK SIMILAR IN SCOPE TO THAT OF THIS PROJECT. z. PRODUCTS a. MANUAL SWINGING DOOR HARDWARE: FURNISHED BY THE OWNER. a. TYPE: AS SCHEDULED ON THE DRAWINGS 3. EXECUTION A. DOORINSTALLATION �) MAINTAIN CLEARANCES OF 1/8 INCH AT JAMBS AND HEADS, AND 1/2 INCH FROM BOTTOM OF DOOR TO TOP OF DECORATIVE FLOOR FINISH OR COVERING, EXCEPT WHERE THRESHOLD IS FURNISHED, PROVIDE 1/41NCH CLEARANCE FROM BOTfOM OPDOOR TO TOP OF THRESHOLD. 2) INSTALL DOORS TO OPERATE FREELY, BUT NOT LOOSELY, FREE FROM HINGE BOUND CONDITIONS, STICKING OR BINDING. DO NOT INSTALL IN FRAMES WHICH WOULD HINDER OPERATION OF DOORS. 3) ENSURE DOORS ARE FREE FROM RATTLING WHEN IN LATCNED POSITION. e. FINISH HARDWARE INSTALLATION �) WSTALL HARDWARE PLUMB, LEVEL AND TRUE TO LINE IN ACCORDANCE WITH MANUFACTURER'S TEMPLATES, PRINTED INSTRUCTIONS AND PROJECT CONDITIONS. 2) INSTALL HARDWP,RE UNITS TO MATCH BUILDING STANDARD MOUNTING HEIGHTS. FOR NEW CONSTRUCTION, MOUNT HARDWARE AS DETAILED. WHERE NOT DETAILED, MOUNT IN ACCORDANCE WITH ADA REQUIREMENTS AND DHI RECOMMENDATIONS. c. ADJUSTMENT: ADJUST AND CHECK FOR PROPER OPERATION AND FUNCTION. REPIAGE UNITS, WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTNLY SECTION a88000 - GLAZING t. GENERAL a. SECTION INCLUDES: �) VISION LITES FOR DOORS. 2) INTERIOR WINDOW GLAZING. 3) GLAZING FOR EXTERIOR STOREFRONTS. e. QUALITYASSURANCE: COMPLY WITH PERTINENT RECOMMENDATIONS IN THE GANA "MANUAL OF GLAZING." 2. PRODUCTS a. CLEAR GLASS: ASTM C1036, TYPE I, CLASS 1(CLEAR), QUALITY Q3 GLAZING SELECT; 1/41NCH THICKNESS, UNLESS OTHERWISE INDICATED. e. TEMPERED GLASS: ASTM C1048; FULLY TEMPERED. c. INSULATING GLASS UNITS: �) EXISTING: WHERE GLAZING IS INDICATED IN RECONFIGURED OR EXTENDED STOREFRONTSYSTEM(UNLESS ENTRANCESTOREFRONT GLAZING IS INDICATED TO BE REPLACED WITH NEVt�, MATCH EXISTING GLAZING TYPE. z) NEW STOREFRONT: 2 LAYERS OF 1/4 INCH CLEAR TEMPERED GLASS WITH 1f2 INCH AIRSPACE; LOW-E COATING TO THE #2 SURFACE; ONE OF THE FOLLOWING. a) GUARDIAN INDUSTRIES CORP. "SUNGUARD SN 68." e) PPG INDUSTRIES INC. "SOLARBAN 60." C VIRACAN "VNE63." ) D. SETTING BLOCKS: NEOPRENE; 70-90 SHORE A DUROMETER HARDNESS; 4 INCHES LONG X 1/4 HIGH X WIDTH AS REQUIRED FOR APPLICATION �73�i�w;i'fi�iiiiHlii� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P:312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � ^ � /��_ GPD GROUP, INC. 520 South Main Street, S�ite 2531 Akron, OH 94311 330.572.2300 Fax: 330.572.2102 ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 �4°4�� � � � � �� ��°� � � m ,� �'`� s �. C°.�i'b � ,�� � �, ' F : `- t t' = t-. ;�m � �'�� � ^ � G �' .. , i; � ,Y� _. SHEET TITLE ARCH ITECTU RAL SPECIFICATIONS SHEET NUMBER AS 1. 2 3. EXECUTION n. INSTALL INSULATING GLASS UNITS IN EXTERIOR STOREFRONTS AND ALUMINUM(GLASS ENTRANCE DOORS. s. INSTALL CLEAR TEMPERED GLASS IN INTERIOR FRAMES AS INDICATED. a SETTWG BLOCKS: PLACE SETTING BLOCKS IN FRAMES FOR SUPPORT OF GLASS. PLACE AT QUARTER POINTS UNLESS APPROVED OTHERWISE. o. SET GLASS TIGHTLY IN POSITION WITH PROPER CLEARANCES IN ACCORDANCE WITH THE FRAME MANUFACTURER'S REQUIREMENTS. a. SCHEDULE: INDICATED ON THE DRAWINGS DIVISION 09-FINISHES 092200 - LIGHTGAGE METAL SUPPORT FRAMING 1. GENERAL n. SECTION INCLUDES 1) PARTITION FRAMING. 2) STEEL BACKING. 3) CEILING AND SOFFIT FRAMIN�. a) FURRING. B. SYSTEM DESCRIPTION �) STRUCTURAL DESIGN OF LIGHTGAGE METAL FRAMING SYSTEMS SHALL BE FURNISHED BY THE CONTRACTOR. z) PARTITION FRAMING SHALL CONFORM TO THEWIDTHS INDICATED, UNLESS APPROVED OTHERWIS6 PROVIDE THICKER GAGES AND DECREASED STUD SPACING AS NECESSARY TO MEET THE DESIGN REQUIREMENTS. 3) DESIGN LOADS: a) INTERIOR CEILING ASSEMBLIES: 5 PSF UNIFORM LIVE LOAD, PLUS DEAD LOADS. s) INTERIOR PARTITIONS: 5 PSF UNIFORM LIVE LATERAL LOAD PLUS WEIGHT OP WALL MOUNTED EQUIPMENT AND CASEWORK.. cp SEISMIC LOADS: SEISMIC DESIGN CATEGORY D. a) DEFLECTION REQUIREMENTS a) MAXIMUM DEFLECTION OF 1/240 FOR FLEXIBLE FINISH MATERIALS SUCH AS �YPSUM BOARD. e) MAXIMUM DEFLECTION OF 1/360 FOR RIGID FINISH MATERIALS SUCN AS CERQMIC TILE. c. QUALITY ASSUR4NCE: UNLESS INDICATED OTHERWISE, PERFORM WORK IN ACCORDANCE N9TH ASTM C754. 2. PRODUCTS a. NON-LOAD BEARING LIGHT GAGE METAL FRAMING: t) FURNISH "C" SHAPED STUDS, DEPTHS AS WDICATED;ASTM C645; GALVANIZED; MINIMUM 25 GAGE (18 MIL). 2) FURNISH U SHAPED TRACKS (RUNNERS), HAT AND "Z" SHAPED FURRWG CHANNELS, AND OTHER SIZES AND SHAPES AS INDICATED ON THE DRAWINGS, AND REQUIRED BY THE REFERENCED STANDARDS. 3) RECYCLED CONTENT: MINIMUM 10 PERCENT CALCULATED (BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER) RECYCLED CONTENL a) PARTITION HEAD COMPENSATING CHANNEL (NON-FIRE RATED}: DESIGN FOR MINIMUM t1l2 WCH DEFLECTION; ONE OF THE FOLLOWING. n) 20 GAGE DEEP LEG TRACK; MINIMUM 2-1/21NCH LEGS. s) PROPRIETARY COMPENSATING CHANNEL SYSTEM, UTILIZING TSN "VERTICLIP SLD," FIRE TRAK INC. "POSI KLIPS," OR SIMILAR SYSTEM AT CONTRACTOR'S OPTION. B. PROPRIETARY CEILING SUSPENSION SYSTEM: �i MANUFACTURER: a) BASIS OF DESIGN: CHICAGO METALLIC (LOS ANGELES CA; 800-323-7164), a) ACCEPTABLE OPTIONS (SUBJECT TO COMPLIANCE WITH CONTRACT DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF CONFORMANCE TO DESIGN INTENT.): (�) USG INTERIORS, INC. (CHICAGQ ILj 800-8744968). (2) ARMSTRONG (800_207_2321). 2) SUSPENSION SYSTEM: SIMILAR TO SYSTEM 650, OR 670; ASTM C635 HEAVY DUTY CIASSIFICATION. c. ACCESSORIES: �) SCREWS: SELF DRILLING, LOW PROFILE HEAD; GALVANIZED. z) CONCRETE ANCHORS: POWERS FASTENERS "POWDER ACTUATED FASTENERS," ITW RAMSET "POWDER FASTENERS," HILTI "POWDER ACTUATED NAILS," OR APPROVED;TYPES AS APPROPRIATE TO THE WORK. 3) HANGER WIRE: ASTM A641; CLASS 1 ZINC COATING; SOFT TEMPER; PRESTRETCHED;12GAGE a) RESILIENT CHANNELS: USG "RG1," OR APPROVED. 5) BACKING DIETRICN INDUSTRIES (RENTON WA; 425_251_1497) °DANBACK FLEXBLE WOOD BACKING PLATE"; UNTREATED; LENGTH AS APPROPRIATE TO STUD SPACING. s) OTHER FRAMING MATERIALS: IN ACCORDANCE WITH ASTM C754. 3. EXECUTION n. INTERIOR PARTITION FRAMING �) RUNNERS: n) SECURE RUNNERS WITH FASTENERS AT MAXIMUM 241NCHES OC. a) TOP RUNNER: SECURE HEAD TRACK TO STRUCTURE WITH ALLOWANCE FOR STRUCTURAL DEFLECTION. (1) NON RATED PARTITIONS: USE PROPRIETARY COMPENSATING CHANNEL OR DEEP LEG TRqCK AT CONTRACTOR'S OPTION, AS NECESSARY TO ACCOMMODATE BUILDING DEFLECTION. (2) FIRE RATED PARTITIONS: INSTALL PROPRIETARY FIRE R4TED RUNNER AND ACCESSORIES AS NECESSARY TO MEET THE FIRE RATING REQUIREMENTS INDICATED ON THE DRAWINGS; COMPLY WITH UL REQUIREMENTS FOR LISTfD ASSEMBLY. c) COORDINATE WITH SECTION 078100 FOR SEQUENCING AND PATCHING OF FIREPROOFING MATERIALS, AS NECESSARY TO MAINTAIN FIRE SEPAR4TION. 2) UNLESS MDICATED OTHERWISE, INSTALL STUDS VERTICALLY AT 24 INCHES O.C, AND NOT MORE THAN 2 WCHES FROM ABUTTING CONSTRUCTION, AT EACH SIDE OF OPENWGS, AND AT CORNERS. 3) FIT RUNNERS UNDER AND ABOVE OPENINGS; SECURE INTERMEDIATE STUDS AT SPACING OF WALL STUDS. a� BRACE PARTITION FR4MING SYSTEM AND MAKE RIGID. 5) INSTALL DOUBLE STUDS CONTINUOUS FROM FLOOR TO CEILWG TRACK AT THE JAMB Of EACH DOOR FRAME AND CASED OPENING. STUDS SHALL BE NO LESS THAN 20 GAGE. PROVIDE DIAGONAL STEEL STUD BRACING TO STRUCTURE AT EACH JAMB AT PARTITIONS WHICH DO NOT EXTENT TO STRUCTURE. s) AT NON-LOAD BEARING FULL HEIGNT PARTITIONS SUBJECT TO COMPRESSION CAUSED BY OVERHEAD STRUCTURAL DEFLECTION, AND WHERE PROPRIETARY COMPENSATING CHANNEL SYSTEM IS NOT USED, CUT STUDS 1/21NCH SHORT FROM FULL HEIGHT. DO NOT RIGIDLY CONNECT STUD TO TOP RUNNER. �) STUD BRIDGING: AT INTERIOR PARTITIONS GREATER THAN 4 FEET IN LENGTH, AND WITH RIGID FACING MATERIAL ON ONE STUD FLANGE ONLY, PROVIDE 3/4" BRIDGING CHANNELS IN HORIZONTAL ROWS AT A MAXIMUM OF 5'-0" O.C. FOR THE FULL HEIGHT OF THE PARTITION. e. BACKING �) PROVIDE STEEL BACKING WHERE INDIGATED. AT THE CONTRACTOR'S OPTION, PROPRIETARY OR STEEL BACKING PLATES MAY BE SUBSTITUTED FOR WOOD BLOCKING INDICATED ON DRAIMNGS. 2) UNLESSJNDICATED OTHERWISE, STEEL BACKING SHALL CONSIST OF MINIMUM 41NCH WIDE 16 GAGE STEEL PLATE SCREWED RIGIDLY TO THE STUDS. c. CEILING FRAMING 1) CEILING FRAMING SHALL CONSIST OF STUD AND RUNNER FRAMING OR SUSPENDED FR4MING, UNLESS INDICATED OR SPECIFIED OTHERWISE. 2) SUSPENDED FRAMING SHALL BE SUSPENDED FROM OVERHEAD STRUCTURAL ELEMENTS ONLY. 3) STUD AND RUNNER FRAMING: A) SECURE RUNNERS TO STRUCTURE ABOVE WITH FASTENERS AT A MAXIMUM OF 241NCHES O.C.. SIZE FASTENERS AND USE REINFORCEMENTS AS NECESSARY TO SUPPORT THE DEAD LOADS. a) SPACE STUDS AT 16 INCHES O.C. AT HORIZONTAL LOCATIONS. 4) LIGHTGAGE SUSPENDED FRAMING: n) INSTALI IN ACCORDANCE WITH ASTM C754, UNLESS INDICATED OR SPECIFIED OTHERWISE. B) SPACE CARRYING CHANNELS 4 FEET O.C. WITH SPLICES LAPPED MINIMUM 121NCHES. c) SUPPORT COLD ROLLED CARRYWG CHANNELS WITH HANGER WIRES SPACED AT 4 FEET O.C. LOOP HANGER WIRE AROUND SUPPORT ELEMENT AND TIGHTLY WRAP AROUND VERTICAL WIRE 3 TIMES; CUT OFF NEATLY. D) SPACE FURRING CHANNELS 16° O.C. WITH SPLICES LAPPED 12", MINIMUM AND TIED; CLIP OR SADDLE TIE TO RUNNER CHANNELS WITH 16-GAGE TIE WIRE. � WHERE OVERHEAD OBSTRUCTIONS PREVENT THE REGULAR SPACING OF HANGERS, PROVIDE SECONDARY CARRYING MEMBERS FOR INDIRECT SUPPORT OF THE SUSPENSION SYSTEM, OR REINFORCE THE NEAREST ADJACENT HANGERS AND RELATED FRAMING COMPONENTS AS NECESSARY TO SPAN THE REQUIRED DISTANCE 5) PROPRIETARY SUSPENDED FRAMING: PER MANUFACTURER'S RECOMMENDATIONS. e) STABILIZE SUSPENDED CEILING FRAMING AGAINST LATER4L MOVEMENT BY MEANS OF DIAGONAL BRACING. 7) INSTALL SUPPLEMENTARY HANGER WIRES FOR SUPPORT OF CEILING MOUNTED EQUIPMENL o. TOLERANCES �) SURFACE PLANE VARIATION: 1/81NCH IN 10 FEET. 2) POSITION: WITHIN 1/4 WCH OF REQUIRED LOCATIONS. 092813 - CEMENTITIOUS BACKING BOARDS t GENER4L a. SECTION INCLUDES: GLASS MESH REINFORCED CEMENT BOARD SUBSTRATE FOR TILE. B. SUBMITTALS: PRODUCT DATA. 2. PRODUCTS n. BOARD MATERIAL: 1/2 INCH NOMINAL THICKNESS AGGREGATED PORTLAND GEMENTPANEL, REINFORCED WITH GLASS FIBER MESH; ONE OF THE FOLLOWING. �) CUSTOM BUILDING PRODUCTS (SEAL BEACH CA; 800-272-8786) "WONDERBOARD." z) FINPAN (HAMILTON OH; 80�_833_6444) °UTIL-A-CRETE." 3) USG CORPORATION (CHICAGO, IL; 312-436-4000) "DUROCK." a) NATIONAL GYPSUM COMPANY (CHARLOTTE NC; 800_628_4662) "PERMABASE." e. TAPE FOR GLASS MESH BOARD: OPEN WEAVE GLASS MESH JOINT TAPE, SELF-ADHESIVE; 2-1/21NCHES WIDE. c. FASTENERS: AS RECAMMENDED BY THE BACKER BOARD MANUFACTURER; THREAD FORMING SELF-DRILLING WAFER HEAD SCREWS; POLYMER COATED OR ZINC PLATED; USG "DUROCK SCREWS," "ROCK-ON," OR APPROVED. D. BONDING MORTAR: THINSET MORTAR, AS SPECIFIED IN SECTION 093000. 3. EXEGUTION a. EXAMINATION t) PRIOR TO STARTING WORK, INSPECT INSTALLED WORK OF OTHER TRADES AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT WHERE WORK OF THIS SECTION MAY PROPERLY COMMENCE. 2) NOTIFY THE ARCHITECT IN WRITING OF CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK. B. INSTALLATION t) WSTALL AT WALLS AS INDICATED ON THE DRAWINGS. 2� INSTALL UNITS WITH EDGES FIRMLY SUPPORTED. 3) ATfACH UNITS WITH SCREWS SPACED 6 INCHES ON CENTER ALONG FRAMWG. a) SPACE BOARDS 1/8 TO 3/16 INCH APART. STAGGER BOARD JOINTS WITN THOSE OF ADJACENT ROWS. FILL JOINTS BETN+EEN GLASS MESH PANELS IMTH BONDING MORTAR, EMBED REINFORCING, COVER OVER WITH BONDING MORTAR AND TROWEL SMOOTH. 092900-GYPSUM BOARD 1. GENER4L A SECTION INCLUOES: �) GYPSUM BOARD AND ACCESSORIES. 2) TROWELTEXTUREDFINISH. 3) PATCHING AND TREATMENT OF EXISTING WALL SURFACES. s. QUALITYASSURANCE: �) PERFORM WORK IN ACCORDANCE WITH GA 216, UNLESS SPECIFIED OTHERWISE, OR REQUIRED OTHERWISE TO MEET FIRE RATING REQUIREMENTS. 2) MOCK-UP: APPLY TROtNEL TEXTURED FINISH TO MINIMUM 4 FOOT SQUARE PIECE OF GYPSUM BOARD, REPRESENTATIVE OF PROPOSED FINISH WR01. 2. PRODUCTS n. MANUFACTURER:ONE OFTHEFOLLOWING. �) CERTAINTEED CORP. 2) GEORGIA-PACIFICGYPSUM,LLC. 3) LAFARGE NORTH AMERICA 4) NATIONAL �YPSUM COMPANY 5) TEMPLE-INLAND INC. s� USG CORP. e. GYPSUM BOARD: �� ASTM C1396; 5/8 INCH THICK; TYPE X FOR USE W FIRE RATED PARTITIONS; CONTR4CTOR'S OPTION AT OTHER LOCATIONS. 2) RECYCLED CONTENT: MINIMUM 9 PERCENT CALCULATED (BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER) RECYCLED CONTENL a WATER RESISTANT BOARD: ASTM C1396; 5/8 INCH THICK. D. INTERIOR GYPSUM TRIM: �) CONFORM TO GA 216, UNLESS INDICATED OR SPECIFIED OTHERWISE. 2) CONCEALED FLANGE CRIMP-ON OR TAPE-0N TYPE; METAL OR PVC AT CONTRACTOR'S OPTION. E. JOINT COMPOUND, TAPE, AND FINISNING CAMPOUND: ASTM C475; PAPER TAPE, TYPICAL; SELF-ADHESIVE FIBERGLASS MESH TAPE FOR USE AT SURFACES TO RECEIVE ADHERED TILE. F. SCREWS: ASTM C1002. 3. EXECUTION a. INSTALLATION STANDARD: PERFORM WORK IN ACCORDANCE WITH GYPSUM ASSOCIATION GA-216. B. INSTALL WATER RESISTANT BOARD WNERE INDICATED AS SUBSTRATE FOR TILE IN TOILET ROOMS. C. SCREW FASTEN BOARD TO PRAMING. D. TRIM: �) USE LONGEST PRACTICAL LENGTHS, WITH NO PIECE LESS THAN 2 FEET LONG FOR CONTINUOUS RUNS GREATER THAN 8 FEET. SECURELY FASTEN AND ALIGN TRIM ENDS AT JOINTS. 2) PLACE CONCEALED FLANGE CORNER BEADS AT ALL EXTERNAL CORNERS. AT ANGLES OTHER THAN 90 DEGREES, BEND THE FLANGE TO CONFORM TO THE ANGLE. 3) PLACE CONCEALED fLANGE TYPE L TRIM WHERE GYPSUM BOARD ABUTS DISSIMILAR MATERIALS. 4) INSTALL CONTROL JOINT TRIM IN GYPSUM BOARD FIELDS WITH CONTINUOUS RUNS IN EXCESS OF 30 FEET, AND IN LOCATIONS AS DIRECTED E. FINISHING: 1) PROVIDE W ACCORDANCE WITH GA 214. 2) WHERE NECESSARY TO SAND, DO SO WITHOUT DAMAGING THE FACE OF THE GYPSUM BOARD. 3) FINISH: A) TYPICAL: GA LEVEL 4. s) TEXTURED FINISH: SKIM COAT TO TROWEL PATTERN TO MATCH APPROVED MOCK-UP. c) SURFACES TO RECEIVED FRP: GA LEVEL L o) SURFACES TO RECEIVE ADHERED TILE: GA LEVEL 0. 093000 - TILING t. GENERAL n. SECTION INCLUDES: �) CERAMICFLOORANDWALLTILE. 2) WATERPROOF MEMBRANES. B. SUBMITTALS: t) PRODUCT DATA: SUBMIT FOR EACH TYPE OF TILE, MORTAR, GROUT, ADHESIVE, ADDITIVE, ACCESSORY, AND MEMBRANE. 2) SAMPLES a) TILE: SUBMIT SAMPLES OF EACH TYPE AND COLOR OF TILE. INCLUDE REPRESENTATIVE R4NGE OF COLORS AND FINISHES TO BE EXPECTED. a) GROUT: SUBMIT CURED SAMPLES OF EACH GROUT COLOR. c) SHOP DRAWINGS: INDICATE FLOOR PLAN WITH PARTITIONS AND EXISTING CONDITIONS AS APPROPRIATE; SHOW PROPOSED EXPANSION JOINT LOCATIONS, FLOOR DRAINS, FLOOR SINKS, RELATIVE ELEVATIONS, AND PITCHES TO DR41N. z. PRODUCTS n. TILE: AS SCHEDULED ON THE DRAWINGS. e. ACCESSORY MATERIALS: AS FOLLOWS, UNLESS OTHERWISE RECOMMENDED BY THE TILE MANUFACTURER. �) TILE WATERPROOFING MEMBRANE: ONE OF THE FOLLOWING. A) NOBLECOMPANY"NOBLESEALTS." B} BOSTIK"HYDROMENTULTRA-SET." c� MAPEI AMERICAS. "MAPELASTIC SMART. ° o) LATICRETE HYDROBAN 2) THINSET MORTAR: IN ACCORDANCE WITH ANSI A118.4; PORTLAND CEMENT WITH 100 PERCENTACRYLIC LATEXADDITIVE n) LATICRETE254PLATINUM 3) EPDXY GROUT: ONE OF THE FOLLOWING COLOR MATCH AS SCHEDULED ON THE DRAWINGS. n) MAPEI AMERICAS "KERAPDXY." s) BOSTIK "HYDROMENT COLOR-PDXY.° c) LATICRETE INTERNATIONAL INC. "SPCTRALOCK 20001G GROUT." 3. EXECUTION n. SLAB LEVELING �) PRIOR TO INSTALLATION OF THINSET FLOOR TILE, NMERE LOCAL IRREGULARITIES IN THE SUBSTR4TE SURFACE WOULD CAUSE PUDDLING, PREVENT LEVEL INSTALLATION OF THE TILE, OR INTERRUPT DRAINAGE PATTERNS, THE SUBSTRATE SHALL BE ADJUSTED AS NECESSARY. USE THINSET MORTAR OR OTHER FILLER FOR SLAB LEVELING. 2) WHERE PITCHES TO DRAIN ARE INDICATED, SLOPE FLOORING MINIMUM 1/S INCH PER FOOT, UNLESS OTHERWISE INDICATED OR DIRECTED. e. EXPANSION JOINTS: t) PROVIDE FOR EXPANSION JOINTS AT MAXIMUM 24 FEET O.C. 2) MATCH MORTAR JOINT WIDTH, EXCEPT THAT JOINTS SHALL BE NO LESS THAN 1/8 INCH WIDE; PROVIDE BETWEEN FLOOR TILE AND BASE AT FIELD PERIMETERS. RAKE JOINTS FREE OF SETTWG MORTAR. C. INSTALLATION OF TILE: INSTALLERS SHALL FOLLOW INSTRUCTION AS OUTLINED IN THE TCNA HANDBOOK FOR CERAMIC TILE, GLASS AND STONE TILE FOR INSTALLATION. 1) INTERIORFLOORAPPLICATION-THINSETOVERCONCRETE SUBSTRATES AND CONCRETE WITH WATERPROOF MEMBRANE. n) TCNASYSTEM:F113. s) INSTALLATION STANDARD: ANSI A108.5. c) SETTING MATERIALS: THINSET MORTAR; 3/321NCH MINIMUM THICKNESS. D) GROUT: EPDXY. 2) WALL APPLICATION (TILE BASES) - GYPSUM BOARD SUBSTRATE AND GYPSUM BOARD WITH WATERPROOF MEMBRANE: A) TCNA SYSTEM: SIMILAR TO W243. B) INSTALLATION STANDARD: ANSI A108.5. c) SETTING MATERIALS: THINSET MORTAR. o) GROUT: EPDXY. 3) WALL APPLICATION - CEMENTITIOUS TILE BACKING BOARD: n) TCNA SYSTEM: SIMILARTO W244. a) INSTALLATION STANDARD: ANSI A108.5. C) SETTING MATERIALS: THINSET MORTAR. D) GROUT: EPDXY. D: GROUTING: COMPLY WITH PROVISIONS OF ANSI A108.10. GROUT ALL JOINTS, EXCEPT EXPANSION JOINTS. FLOAT JOINTS TO A SLIGHTLY CONCAVE PROFlLE. 095410 - SUSPENDED PANEL CEILINGS t GENERAL A. SECTION INCLUDES: �) SUSPENSION SYSTEM 2) PANEL CEILING. 3) METAL PANEL CEILING AND TRIM e. QUALITY ASSURANCE: PERFORM NEW WORK AS NECESSARY TO MAINTAIN COMPLIANCE tMTH IBC 1621.2.5, SEISMIC DESIGN CATEGORY D, AND THE REQUIREMEN7S OF THE JURISDICTIONAL CODE AUTHORITIES: z. PRODUCTS n. SUSPENSION SYSTEM: 1) SEISMIC DESIGN CATEGORIES A OR B: n) EXPOSED T SYSTEM; ARMSTRONG "360° PAINTED," WIDTH AS SCHEDULED; UIMITE, UNLESS OTHERWISE INDICATED. e) WALL MOLDINGS: 7/8 OR 1 INCH FLANGE. 2) SEISMIC DESIGN CATEGOPoES C, D, E, OR f: a� EXPOSED T SYSTEM; ARMSTRONG "SEISMIC RX," WIDTH AS SCHEDULED; WHITE, UNLESS OTHERWISE INDICATED. a) WALL MOLDINGS: 7/8 OR 1 INCH FIANGE; INCLUDE SEISMIC CLIPS FOR ATTACHMENT OF GRID MEMBERS; ARMSTRONG "BERC2 2° BEAM END RETAINING CLIP," ORAPPROVED. a. ACOUSTICAL PANELS: AS SCHEDULED �) RECYCLED CONTENT: MINIMUM 15 PERCENT CALCULATED (BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER) RECYCLED CONTENL 2) TOXICITY/IEQ: a) FREE FROM ADDED UREA-FORMALDEHYDE e) WCLUDE MANUFACTURER'S STANDARD ANTI-MICROBIAL TREATMENT: c. METAL PANELS AND TRIM: AS SCHEDULED, D. ACCESSORIES: FURNISH HANGERS, CLIPS, FASTENERS, NANGER WIRE AND OTHER ACCESSORIES AS NECESSARY TO COMPLETE THE WORK. 3. EXECUTION n. INSTALL SYSTEM IN ACCORDANCE WITH ASTM C636, IBC 16212.5 AND CISCA 1-2 OR CISCA 3_4 AS APPROPRIATE TO THE SEISMIC DESIGN CATEGORY, THE MANUFACTURER'S INSTRUCTIONS, AND AS FOLLOWS. �) INSTALL ADDITIONAL HANGER WIRES AS NECESSARY TO SUPPORT SUPERIMPOSED LOADS. 2) COORDINATE WITH MECHANICAL, ELECTRICAL, AND FIRE PROTECTION WORK FOR ACCOMMODATION OF PENETRATING ELEMENTS. 3) SET PANELS INTO CEILING GRID. n) BORDER UNITS: VNiERE PARTIAL PANELS ARE NECESSARY FOR INSTALLATION AGAINST WALL MOLDINGS, SCRIBE AND CUT PANELS TO FIT THE OPENINGS; INSTALL EACH PANEL WITH CUT EDGE FULLY SUPPORTED BY WALL MOLDING. s) FIELD UNITS: WHERE CUT PANELS ARE NECESSARY TO ACCOMMODATE FRAMING AT LIGHT FIXTURES, DIFFUSERS, AND OTHER INTERRUPTIONS IN THE SUSPENSION SYSTEM MODULE, SCRIBE AND CUT PANELS TO ACCOMMODATE THE FRAMWG OR PENETRATION. e. CLEAN-UP: REMOVE FINGERPRINTS, SOIL AND BLEMISHES FROM CEILING MATERIALS. USE CLEANING MATERIALS RECOMMENDED BY THE MANUFACTURER OF TNE CEILING MATEWALS. SECTION 096519 - RESILIENT TILE FLOORING t. GENERAL n. SECTION INCLUDES: VINYL COMPOSITION TILE FLOORING. B. SUBMITTALS �) PRODUCT LITERATURE: INCLUDE DESCRIPTIONS OF PHYSICAL CHARACTERISTICS AND INSTALI.ATION INSTRUCTIONS FOR RESILIENT FLOORING, ADHESIVES, LEVELWG COMPOUNDS, AND ACCESSORIES. 2� SAMPLES: 3 FULL SIZE TILES FOR EACH TYPE AND COLOR OF RESILIENT TILE FLOORING MATERIAL. 3) PRODUCT DATA: A) FOR EACH TILE TYPE, INDICATE RECYCLED CONTENT; INDICATE PERCENTAGE OF PRE-CONSUMER AND POST-CONSUMER RECYCLED CONTENT PER UNIT OF PRODUCT; INCLUDE CERTIFICATION TO RFCI FLOORSCORESTANDARD. a) INCLUDE MSDS SHEETS OR OTHER EVIDENCE THAT SHOWS COMPLIANCE TO VOC REQUIREMENTS FOR FILLERS AND ADHESIVES. c. ENVIRONMENTALREQUIREMENTS �) MAINTAIN MINIMUM 70 DEGREES F AIR TEMPERATURE AT FLOORING INSTALLATION AREA FOR THREE DAYS PRIOR T0, DURING, AND FOR 24 HOUR3 AFTER INSTALLATION. 2) STORE FLOORING MATERIALS IN AREA OF APPLICATION; ALLOW MATERIALS TO ACCLIMATE TO ENVIRONMENTAL CONDITIONS PRIOR TO INSTALLATION. �. EXTRA STOCK: DELIVER 10 PERCENT EXTRA STOCK OF EACH COLOR AND PATTERN OF FLOOR MATERIAL REQUIRED FOR PROJECT, FOR MAINTENANCE USE, PROPERLY PACKAGED AND CLEARLY LABELED. 2. PRODUCTS a. RESILIENT TILE FLOORING: AS SCHEDULED; CERTIFIED WITH RFCI FLOORSCORE STANDARD. B. ACCESSORIES �) SUBFLOOR FILLER: WHITE PREMIX LATEX FILLER, MIXED WITH WATER TO PRODUCE A CEMENTITIOUS PASTE. 2) PRIMER TOXICITY/IEQ: WATER-BASED; CLEAR; OF TYPES AS APPROVED BY RESIUENT fL00RING MANUFACTURER FOR SPECIFlC MATERIAI. AND SUBSTRATESENCOUNTERED. 3) ADHESIVES: A) TYPES RECOMMENDED BY RESILIENT FLOORING MANUFACTURERS FOR SPECIFIC APPLICATION. e) TOXICITY/IEQ: COMPLY WITH APPLICABLE REGULATIONS REGARDWG TOXIC AND HAZARDOUS MATERIALS, GS_36 FOR COMMERCIAL ADHESIVE, AND SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. a) TRANSITION STRIPS: VINYL; PROFILE(S) AS INDICATED; COLOR AS SELECTED BY THE ARCHITECT FROM MANUFACTURER'S STANDARD. 5� ALL OTHER MATERIALS NOT SPECIFICALLY DESCRIBED, BUT REQUIRED FOR A COMPLETE AND PROPER INSTALLATION OF RESILIENT FLOORING, SHALL BE ONLY AS RECOMMENDED BY THE MANUFACTURER OF THE MATERIAL TO 4VHICH IT IS APPLIED AND SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT. 3. EXECUTION a. MOISTURE TESTING OF CONCRETE SLABS: PERFORM ANHYDROUS CALCIUM CHLORIDE TESTS IN ACCORDANCE WITH ASTM F1869 TO DETERMINE THE VAPOR EMISSION RATE FROM THE CONCRETE SLAB. NOTIFY THE ARCHITECT IF TESTS RESULTS SHOW A VAPOR EMISSION RATE WHICH EXCEEDS 3 LBS PER 1000 SF. IN A 24 HOUR PERIOD. B. PREPARATION: INSTALL SUBFLOOR FILLER TO FILL LOW SPOTS, CRACKS, CONSTRUCTION JOINTS, HOLES AND OTHER DEFECTS, AND AS REQUIRED TOADJUSTLEVELTOMEETADJACENTFINISHES. FEATHERTOMAXIMUM SLOPE OF 1/8 INCH IN 3 FEET; FLOAT TO SMOOTH, FLAT, HARD SURFACE. PROHIBIT TRAFFIC OVER FILLER. a FLOORING INSTALLATION t) MIX TILE TO ENSURE SHADE VARIATIONS DO NOT OCCUR WITHIN ANY ONE AREA. z) UNLESS INDICATED OTHERWISE, INSTALL FLOORING WITH JOINTS AND SEAMS PARALLEL TO BUILDING LINES. INSTALL WITH MINIMUM TILE WIDTH 1/2 FULL SIZE ATROOM ORAREA PERIMETER. 3) ARRANGE TO SQUARE GRID PATTERN WITH ALL JOINTS ALIGNED. UNLESS OTHER4UISE INDICATED, INSTALL WITH PATTERN GRAIN ALTERNATING WITH ADJACENT UNIT TO PRODUCE BASKET WEAVE PATTERN (WHERE APPROPRIATE). 4) TERMINATE RESILIENT FLOORING AT CENTERLINE OF DOORAT DOOR OPENINGS WHERE ADJACENT FLOOR FINISH IS DISSIMILAR, AND WHERE NO THRESHOLD IS INDICATED. 5) INSTALL EDGE STRIPS AT UNPROTECTED OR EXPOSED EDGES WHERE FLOORING TERMINATES. 097200 - WALL COVERING t GENERAL a. SECTION INCLUDES: INSTALLATION OF O+NNER FURNISHED WALL COVERINGS. s. SUBMITTALS: SUBMIT PRODUCT DATA FOR PROPOSED ADHESIVES AND ACCESSORIES. INCLUDE MSDS SHEETS OR OTHER EVIDENCE THAT SHOWS COMPLIANCE TO VOC REQUIREMENTS FOR ADHESIVES. C. QUALITY CONTROL: WALL COVERI G INSTALLER SHALL HAVE MWIMUM OF N 3 YEARS EXPERIENCE IN WALL COVERING INSTALLATIONS OF SIMILARAND SCOPE. D. DELIVERY, STORAGE, AND HAND�ING: STORE WALL COVERING MATERIALS FLAT, NOT UPRIGHT, IN A DRY AREA. MAINTAIN TEMPERATURE OF STORAGEAREAAT A MINIMUM OF 45 DEGREES F., UNLESS A HIGHER TEMPERATURE IS RECOMMENDED BY WALL COVERING MANUFACTURER. E. ENVIRONMENTALCONDITIONS t) TEMPERATURE: a) DO NO WALL COVERING WORK UNTIL SURFACES AND MATERIALS HAVE BEEN MAINTAINED AT 60 DEGREES F. MINIMUM, OR HIGHER IF RECOMMENDED BY WALL COVERING MANUFACTURER, FOR 3 DAYS BEFORE WORK BEGWS. B) MAINTAIN MINIMUM ORABOVE TEMPERATURES DURING THE ENTIRE INSTALLING TIME AND UNTIL ADHESIVES HAVE FULLY DRIED OR CURED. 2) LIGHTING: DURING INSTALLATION, MAINTAIN MINIMUM LIGHTING LEVEL OF 15 FOOT-CANDLES ON THE SURFACES TO RECEIVE WALL COVERING. USE TEMPORARY LIGHTING, IF NECESSARY, TO ATTAIN SPECIFIED LEVEL. 2. PRODUCTS n. WALL COVERING: TYPES AS SCHEDULED ON THE DRAWINGS; FURNISHED BY THE OWNER. e. ADHESIVES: AS RECOMMENDED BY THE WALL COVERING MANUFACTURER FOR THE APPLICATION. ADHESIVES SHALL MEET THE REQUIREMENTS OF THE SOUTHERN CALIFORNIA SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE 1168. a. EXECUTION A. EXAMINATION: ENSURE THAT SURFACES TO RECEIVE WALL COVERING HAVE RECENED A COAT OF WALL SIZE AS SPECIFIED IN SECTION 099000. a. PREPARATION: REMOVE ELECTRICAL OUTLET AND SWITCH PLATES, MECHANICAL DIFFUSERS, ESCUTCHEONS, REGISTERS, SURFACE HARDWARE, FITTINGS, AND FASTENINGS PRIOR TO STARTING WORK; STORE DURING AND REPLACE AFTER COMPLETION OF WORK. c. INSTALLATION 7) MIX AND APPLY ADHESIVES IN ACCORDANCE WITH THE ADHESIVE MANUFACTURER'S DIRECTIONS FOR THE TYPE OF MATERIAL BEING APPLIED. 2) INSTALL WALL COVERING SECURE, SMOOTH, CLEAN, AND WITHOUT WRINKLES, GAPS OR OVERLAPS. 3) EXTEND WALL COVERING CONTWUOUSLY BEHIND ITEMS WHICH ARE CLOSE TO BUT NOT TOUCHING WALLS. a) PROVIDE DOUBLE-CUT SEAMS ON NONMATCH PATTERNS; BUTT SEAMS ON MATCH PATTERNS. 5) INSTALL WALL COVERING ORIENTED VERTICALLY, UNLESS OTHERWISE INDICATED. s) CORNER SEAMS: MAKE NO SEAMS WITHIN 6 INCHES OF AN INSIDE OR OUTSIDE CORNER, EXCEPT WHERE A COLOR OR PATTERN CHANGE IS INDICATED. LAP WALL COVERINGS AT INSIDE CORNER SEAMS TO PREVENT SUBSTRATE SHOW THROUGH. 097243 STAINLESS STEEL WALL CAVERING t. GENERAL a. SECTION INCLUDES: STAINLESS STEEL SHEET ADHERED DIRECTLY TO THE WALL. a. PRODUCT LITERATURE: ADHESIVE. c. SUBMITTALS: ASNECESSARYTO COORDINATE FABRICATION WITH FIELD DIMENSIONS. o. ENVIRONMENTAL CONDITIONS �) ACCLIMATIZE TO AMBIENT TEMPERATURE (-70 DEGREES F) BEFORE INSTALLATION. 2) MAINTAIN ADEQUATE VENTILATION AND CONDITIONS TO PREVENT COMBUSTION OP ADHESIVE FUMES. 2. PRODUCTS n. STAINLESS STEEL SHEET PANELS: FURNISHED BY THE OWNER. e. WATER RESISTANT CONTACT BOND ADHESIVE; MAXIMUM VOC 250 G/L. 3. EXECUTION n. EXAMINATION: ENSURE THAT SURFACES TO RECEIVE WALL COVERING HAVE RECEIVED A COAT OF WALL SIZE AS SPECIFIED IN SECTION 099000. e. INSTALLATION �) COORDINATE WITH OTHER TRADES TO ACCOMMODATE ADJACENT FINISNES. 2) DRY FIT SHEETS INTO PLACE BEFORE APPLYING ADHESIVE. 3) CUT HOLES ACCUR4TELY TO CONFORM TO THE PENETR4TION, AND OVERSIZED BY 1/16" ALL AROUND. 4) CLEAN SUBSTRATE AND PANEL SURFACES. 5) APPLYADHESIVE IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED APPLICATION INSTRUCTIONS. 6) TROWELAPPLYADHESIVECONTINUOUSLYOVERSUBSTRATE.80ND EACH SHEET TO THE SUBSTRATE BY PROGRESSING FROM ONE SIDE TO THE OTHER TO EXPEL ALL AIR. APPLY PRESSURE UNIFORMLY TO THE FACE OF THE SHEET BY USING A WIDE HARD RUBBER ROLLER. �) ALLOW 1/16 INCH EXPANSION SPACE BETWEEN PANELS AND AT ALL SURROUNDING CONSTRUCTION. C. REMOVE ADHESIVE FROM FACE OF PANELS USING SOLVENT RECOMMENDED BYADHESIVE MANUFACTURER. 097736- FIBERGLASS REINFORCED PLASTIC PANEL WALL COVERINGS t. GENERAL n. SECTION INCLUDES: FIBERGLASS REINFORCED PLASTIC (FRP) WALL COVERING PANEL SYSTEM. a. SUBMITTALS �) PRODUCT LITERATURE. 2) SAMPLES n) EACH TYPE OF JOINT/TRIM PROFILE; MWIMUM 121NCHES LONG; B) PROPOSED PANEL; MINIMUM 12 X 121NCHES c. QUALITY ASSUR4NCE: MATERIALS AND INSTALLATION SYSTEM SHALL BE USDA APPROVED FOR FOOD PREPARATION AREAS. 2. PRODUCTS a. FRP PANEL SYSTEMS: COMPOSITE PANEL CONSISTING OF UNIFORM FIBERGLASS GLASS FIBERS EMBEDDED IN ORGANIC RESIN; CLASS C FIRE RATING; 0.091NCH THICKNESS. t) TYPE: A) BASIS OF DESIGN: MARLITE (DOVER, OH; 800-377-1221) `MARLITE STANDARD FRP:' e) ACCEPTABLE OPTION (SUBJECT TO COMPLIANCE WITH CONTRACT DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF COLOR AND CONFORMANCE TO DESIGN INTENT.): CRANE COMPOSITES (CHANNAHON, IL; 800_435_0080) "SEQUENTIA STRUCTOGLAS FTSTJ SANITARY EMBOSSED WALL PANELS " 2) COLOR: P199 "PEBBLED SURPACE"; "BRIGHT WHITE." e. ADHESIVE: "G551 MARLITE FRP ADHESIVE;' UNLESS OTHERWISE RECOMMENDED BYTHE PANEL MANUFACTURER FOR THE SUBSTRATE INDICATED; VOC MAXIMUM 50 G/L. c. SEALANT: MANUFACTURER'S STANDARD SILICONE SEALANT; WHITE. o. TRIM MOLDINGS: MANUFACTURER'S STANDARD PVC; COLORTO MATCH PANELS. t) EDGE (J): M37�. 2) DIVISION (H): M365 3) INSIDE CORNER: M350. a) OUTSIDE CORNER: M360. 3. EXECUTION a. PREPARATION : COORDINATE INSTALLATION WITN THE INSTALLERS OF ADJACENT AND INTEGRAL CONSTRUCTION TO ALLOW FOR INSTALLATION OF FRP PANELS PRIOR TO THE INSTALLATION OF ESCUTCHEONS, COVER PLATES, LOUVER FLANGES, AND OTHER COMPONENTS TO BE INSTALLED OVER OR THROUGH FRP PANELS. e. ADHESIVE WALL PANEL INSTALLATION t) ACCURATELY CUT AND FIT PANELS AROUND OBSTRUCTIONS; SCRIBE FIT AT EDGES. 2) DO NOT INSTALL PANELS WITH EDGE OR SURFACEbAMAGE. REPLACE WITH NEW UNDAMAGED MATERIAL, ALL PANELS WHICH BECOME CHIPPED OR DAMAGED PRIOR TO FINAL ACCEPTANCE. 3) PROVIDE J MOLDING AT ALL EXPOSED EDGES. PROVIDE H MOLDING AT ALL VERTICAL BUTT JOINTS. H MOLDINGS SHALL NOT BE RUN BEHIND BASE FINISH MATERIAL. PROVIDE TRIM MOLDINGS AT INSIDE AND OUTSIDE CORNERS. 4) SEAL ALL JOINTS BETWEEN PANELS AND MOLDINGS, AND BETWEEN FRP SYSTEM AND ADJACENT CONSTRUCTION. c. CLEAN-UP: REMOVE SOIL AND BLEMISHES FROM WP,LL MATERIALS. 099000 - PAINTING t GENERAL n. SECTION INCLUDES: SITE APPLIED INTERIOR PAINT COATINGS. B. APPLICATOR QUALIFICATIONS: COMPANY SPECIALIZWG IN COMMERCIAL PAINTING AND FINISHING WITH A MINIMUM OF THREE YEARS DOCUMENTED EXPERIENCE. c. MAINTENANCE STOCK: FURNISH OVER4GE OF PAINT MATERIALS EQUAL TO 10 PERCENT MINIMUM OF QUANTITY OF EACH FINISH PAINT SYSTEM COMPONENT, COLORAND SHEEN REQUIRED FOR THE WORK, BUT FURNISH NOT MORE THAN ONE FULL ONE GALLON CANS, NOR LESS THAN TWO FULL ONE PINT CANS, OF EACH TYPE. OVERRUNS IN EXCESS OF ONE GALLON MAY BE FURNISHED TO THE OWNER AT THE CONTRACTOR'S OPTION. OVER4GE SHALL BE TAKEN FROM THE BATCH MIX FURNISHED FOR THE WORK. OVERAGE SHALL BE FURNISHED IN COMPLETELY FILLED, PROPERLY LABELED,SEALED CANS. 2. PRODUCTS n. INTERIOR LATEX WAIL AND CEILWG PAINT SYSTEM; COLOR MATCH AS SCHEDULED. t) MANUFACTURER: BENJAMIN MOORE PAINT COMPANY 2) GYPSUM BOARD PRIMER: "NATURA INTERIOR WATERBORNE PAINT PRIMER 511"; ZERO VOC 3) METAL PRIMER (DTM): "IRONCLAD LATEX LOW LUSTRE METAL & WOOD ENAMEL C363"; MAXIMUM VOC CONTENT 150 G/L. a) WOOD PRIMER: "IRONCLAD LATEX LOW LUSTRE METAL & WOOD ENAMEL C363°; MAXIMUM VOC CONTENT 150 G/L. 5} FINISH: n) EGGSHELL: "NATURA INTERIOR WATERBORNE PAINT EGGSHELL 513"; ZERO VOC e) SEMI-GLOSS: "NATURA INTERIOR WATERBORNE PAINT SEMI-GLOSS 514"; ZERO VOC e. INTERIOR TRANSPARENT FINISH SYSTEM. �) STAIN: AS SCHEDULED. 2) TRANSPARENT FINISH: MINWAX "POLYCRYLIC PROTECTIVE FINISH," OR APPROVED; SATIN SHEEN UNLESS OTHERWISE INDICATED. c. ACRYLIC WALL SIZE: BENJAMIN MOORE PAINT COMPANY "MOORE'S WALL-GRIP 203." 3. EXECUTION n. PREPARATION: �) MOISTURE CHECK: CHECK FOR EXCESS MOISTURE USING AN EIECTRONIC MOISTURE METER. DO NOT PAINT MATERIALS WITH EXCESS MOISTURE LEVELS IMiICH WOULD IMPAIR THE BONDING OF FINISH COATINGS. 2) HARDWARE AND MISCELLANEOUS ITEMS A) CAREFULLY REMOVE ELECTRICAL OUTLET AND SWITCH PLATES, MECNANICAL DIFFUSERS, ESCUTCHEONS, SURFACE HAROWARE, FITTINGS AND FASTENINGS PRIOR TO STARTING WORK.CAREFULLY STORE, a� CLEAN AND REPLACE THESE ITEMS UPON COMPLETION OF WORK IN EACH AREA. 3) REMOVE DIRT, DUST, GREASE, OIL, MOISTURE, AND OTHER CONTAMINANTS WHICH WILL IMPAIR THE PROPER ADHESION OF THE FINISH. a) MASK ADJACENT SURFACES. a. APPLICATION REQUIREMENTS 1) UNLESS SPECIFIED OR INDICATED OTHERWISE, FOLLOW PAINT MANUFACTURER'S LABEL DIRECTIONS FOR GENER4L APPLICATION PROCEDURESAND COVERAGERATES. 2) OPAQUE FINISHES: n) APPLY NUMBER OF COATS SCHEDULED, EXCEPT THAT ADDITIONAL FINISH COATS SNALL BE APPLIED AS NECESSARY FOR COMPLETE HIDING OF SUBSTRATE COLORS. a) APPLY PRIMER COATS UNTINTED. WHERE MORE THAN ONE COAT OF PAINT IS REQUIRED, TINT EACH SUCCEEDING COAT UP TO THE FINAL COAT SIMIIAR IN TINT, BUT SLIGHTLY LIGHTER IN VALUE (SHADEJ. C) SAND LIGHTLY BETWEEN COATS IF NECESSARY TO ACHIEVE REQUIRED FINISH; SAND BETWEEN ALL COATS APPLIED TO WOOD SUBSTRATES. D) ROLLERS FOR APPLICATION AND BACKROLLING OF LATEX PAINTS SHALL HAVE A NAP OF 3(8 INGH OR LESS. E) WHERE ROLLER TEXTURE IS SCHEDULED FOR APPLICATION TO GYPSUM BOARD SURFACES, FINISH COATS MAY BE ROLLER-APPLIED, OR SPRAY APPLIED AND BACKROLLED AT CONTRACTOR'S OPTION. 'r. �� �. r=�:y ► ; , r ,, a , 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P:312.951.0600 F:312.951.0300 UUWW.POTBELLY.COM � � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Faz:330.572.2102 M � � 0 � 0 N � w m � � Z U w O � a $ �m°°���0� � as.a��� �iaa� f ~Q N. � � � ��'° � ' `�' �=., ^J �, ' a �;'�� ,� � .^ �; `�,3 � A �, _ . . � �. �; � � SHEET TITLE ARCHITECTURAL SPECIFICATIONS SHEET NUMBER AS 1.3 a GYPSUM BOARD-LATEX SYSTEM: �) SYSTEM: THREE COATS - FIRST COAT LATEX PRIMER SEALER (UNTINTED), SECAND AND THIRD COAT LATEX PAINT (OMIT THIRD COAT AT PREVIOUSLY PAINTED WALLS SUBJECT TO APPROVAL BY THE ARCHITECT.) 2) SHEEN: ROLLER TEXTURE; SHEEN AS SCNEDULED. 3) APPLICATION: a) EXCEPT AS OTHERWISE INDICATED, USE ON ALL EXPOSED GYPSUM BOARD SURFACES INDICATED TO BE PAINTED OR REPAINTED. e� PROVIDE PRIME COAT ONLY BEHIND PERMANENTLY MOUNTED MECHANICALLY ANCHORED ITEMS C) DO NOT APPLY PRIMER OR PAINT COATINGS TO SURFACES TO RECEIVE WALI COVERING. D. GYPSUM BOARD - SURPACES TO RECEIVE WALL GOVERING: APPLY ONE COAT OF ACRYLIC WALL SIZE. E. FERROUSMETALANDGALVANIZED-ACRYLICSYSTEM: 1� SYSTEM: THREE COATS; FIRST COAT ACRYLIC DTM PRIMER (OMIT AT SHOP PRIMED ITEMS); SECOND AND THIRD COATS LATEX FINISH. THE PRIMER MAY BE DELETED AT FACTORY PRIMED SURFACES, EXCEPT AS NECESSARY TO RECOAT DAMAGED OR ABRADED PREPRIMED SURFACES. 2) SHEEN: SEMI-GLOSS. 3) APPLICATION: INTERIOR FERROUS METAL SURFACES SCHEDULED EOR PAINT FINISH INCLUDING INTERIOR HOLLOW METAL DOORAND FRAME AND ELECTRICAL PANELS. F. WOOD - ACRYLIC SYSTEM: t) SYSTEM: PROVIDE THREE COATS; FIRST COAT WOOD PRIMER; SECOND AND THIRD COATS LATEX FINISH. 2) APPLICATION: INTERIOR WOOD TRIM AND PANEL SURFACES SCHEDULED FOR PAINT FINISH. �. WOOD - ACRYLIC SYSTEM: �) SYSTEM: UNLESS OTHERWISE SCHEDULED OR DIRECTED, PROVIDE THREE COATS; FIRST COAT STAIN, SECOND AND THIRD COATES CLEAR PROTECTIVE FINISH. 2) APPLICATION: INTERIOR WOOD TRIM AND PANEL SURFACES SCHEDULED POR STAIN FINISH. H. CLEANUP 1) AS THE WORK PROCEEDS AND ON COMPLETION OF THE WORK, PROMPTLY REMOVE ALL PRIMERS, PAINTS AND FINISHES WHERE SPILLED, SPLASHED OR SPLATTERED IN A MANNER NOT TO DAMAGE THE SURFACE FROM WHICH IT IS REMOVED. 2i REMOVE MASKING. 099734-APPLIED CONCRETE FINISHING SYSTEMS 1. GENERAL A. SECTION INCLUDES: STAIN AND SEALER FOR INTERIOR SLAB SURFACES. e. QUALITYASSURANCE c. INSTALLER QUALIPICATIONS: FLOORCARE USA PLEASE CONTACT: BRIAN BRUNNER FLOORCARE USAy INC. � 2236 W. BLUEMOUND ROAD UNIT E. � WAUKESHA, WI53186 � � . . � OFFICE:262-786-0770 X111 � � .. FAX:262 786-5284 � � W W W.FLOORCARE-USA.COM D. PROJECT CONDITIONS t) MAINTAIN AN AMBIENT TEMPERATURE BETWEEN 50 DEG F AND 90 DEG F DURWG APPLICATION AND FOR AT LEAST 48 HOURS AFTER APPLICATION. 2i PROVIDE ADEQUATE VENTILATION. 2. PRODUCTS A. STAIN AND SEALER SYSTEM: �) MANUFACTURER: L.M. SCOFIELD COMPANY (LOS ANGELES, CA; 323-720-3000)(DOUGLASVILLE, GA; 770-920-6000) 2) STAIN: n) STAIN: ONLYAS DIRECTED BY PSW B) COLOR: COLORS, PROPORTIONS, AND TECHNIQUES AS DIRECTED BY THE OWNER'S REPRESENTATIVE, TO MATCH OWNER'S SAMPLE 3) SEALER: SELECTSEAL-W; WATERBORNE LOW VOC CLEAR ACRYLIC POLYURETHANE SEALER; SEMI-GLOSS SHEEN. s. EXECUTION A. EXAMINATION: PRIOR TO APPLICATION OP EACH PRODUCT, VERIFY THAT SURFACES TO BE COATED ARE WITHIN HUMIDITY AND PH RANGES REQUIRED BY THE MANUFACTURER OF EACH SYSTEM. a. PREPARATION 1) CLEAN SURFACES TO RECEIVE STAIN/SEAIERAND TOPCOAT, USWG MANUFACTURER'S RECOMMENDED CLEANING COMPOUNDS, AND IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 2) MASK OR OTHERWISE PROTECT ADJACENT SURFACES. C. APPLICATION 1) STAIN AND SEALER SYSTEM: n) STAIN: (1) APPLY TO EXPOSED CONCRETE FLOOR SURFACES, AS SCHEDULE0. (2) SPRAY APPLY; MAWTAIN A WET EDGE. (3) MULTIPLE COATS QF REQUIRED): UNLESS OTHERWISE DIRECTED, ALLOW EACH APPLICATION TO DRY FOR A MINIMUM OF 4 HOURS, BEFORE PROCEEDWG. e) SEALER: AFTER STAIN HAS DRIED THOROUGHLY, ROLL APPLY SEALER IN ACCORDANCE WITH THE MANUFACTURER'S APPLICATION INSTRUCTIONS. APPLY TWO COATS UNLESS OTHERWISE RECOMMENDED OR REQUIRED TO MATCH APPROVED MOCK-UP. D. PROTECTION: PROTECT FLOOR FROM TRAFFIC FOR AT LEAST 48 HOURS AFTER FINAL APPLICATION OF SEALER. DIVISION 10-SPECIALTIES 101400 - SIGNAGE 1. GENERAL: A. SECTIONINCLUDES, �) INSTALLATION OF SIGNAGE FURNISHED BY THE OWNER. 2) CODE REQUIRED, INFORMATIONAL AND DIRECTIONAL AT LOCATIONS INDICATED ON THE DRAWINGS. B. REGULATORY REQUIREMENTS: SIGNAGE SHALL CONFORM TO THE REQUIREMENTS OFTHE JURISDICTIONAL CODE AUTHORITIES. z. PRODUCTS A. GENERAL: FURNISH SIGNAGE SIMILAR TO DETAILS. FOR CUSTOM SIGNAGE, FONT SHALL BE OPTIMA, OR APPROVED. e. DECALS 1) TYPICAL: PROVIDED BY OWNER. 2) THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED: PROVIDED UNDER SECTION 087103. c. HANDICAPPED TOILET ROOM SIGNS 1) MANUFACTURER: SS GR4PHICS INC (WYANDOTTE MI; 800-513-1695), OR APPROVED. z) SIGNS: 6 X 9 INCHES; HIGH IMPACT STYRENE; WHITE ON BLUE GRAPHICS; GR4DE II BRAILLE; FONT MANUFACTURER'S STANDARD; MINIMUM 5/8 INCH HIGH TEXT AS INDICATED. D. ILLUMINATED SIGNAGE: PROVIDED BY THE OWNER. e. FABRICATION: SIGNS SHALL BE FREE OF ROUGH EDGES, IRREGULAR SURFACES, NON UNIFORM FINISHES, AND SIMILAR IMPERFECTIONS. 3. EXECUTION: n. GRAPHICS SHALL BE MOUNTED LEVEL AND PLUMB AND IN ACCUR4TE ALIGNMENT. e. PLAQUES: 1) CLEAN SURFACES AS NECESSARY TO ACCEPT MOUNTWG TAPE. 2) USE DOUBLE STICK TAPE FOR MOUNTING UNLESS APPROVED OTHERWISE. c. DECALS: ADHERE TO SUBSTRATE FREE OF BUBBLES. o. COORDWATE WITH OWNERS VENDOR FOR INSTALLATION OF OWNER FURNISHED SIGNAGE. N7:1'�i t�oi'i'iE# i�+7i lH iil� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P:312.951.0600 F:312.951.0300 NNINV.POTBELLY.COM � /��_ GPD GROUP, WC. � 520 South Main Street, Suite 2531 Akron, OH 99311 330.572.2100 Fax: 330.572.2102 � �C..�..� GN 1..1.� Q U � z N M � � z � � � 0 � 0 N � w m � � Z U w O � a 0066�j � ° 6Y�/^ ��BBb a/ o bw6ro 1 9 C > m S y� A'�D i . ap � *,+� ^ ,e ��i +; ,":r, , ''; i�, s �, ^�r�� �', � s�.;y: . �P � �k ;� 1.` SHEET TITLE ARCHITECTURAL SPECIFICATIONS SHEET NUMBER AS 1.4 HVAC SYMBOLS LEGEND AIR HANDLING EQUIP. & MATERIALS: DUCTWORK & ACCESSORIES: FIRE PROTECTION SYSTEM: ROOF TOP UNITS SHEETMETAL DUCTWORK ACOUSTICAL DUCT LINER DETAIL DESCRIPTION ROOF TOP UNITS SHALL BE FURNISHED AND INSTALLED BY LL. ALL DUCTWORK TO BE RIGID SHEET METAL CONSTRUCTED FROM GALVANIZED SHEET STEEL IN UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE MINIMUM OF R-5.6 GLASS FIBER �, THIS CONTRACTOR SHALL CAREFULLY REVIEW WORK LETTER TO DETERMINE SCOPE OF ACCORDANCE WITH SMACNA LOW VELOCITY DUCT CONSTRUCTION STANDARDS. FIBERGLASS ACOUSTICAL DUCT LINER ON SUPPLY AND RETURN DUCTWORK WITHIN 10 PEET OF THE WORK. THIS CONTRACTOR SHALL PROVIDE ALL MATERIALS AS NECESSARY TO MAKE DUCTBOARD IS NOT ALLOWED. ALL EXPOSED DUCTWORK TO BE ROUND, SPIRAL, OR RECTANGULAR DISCHARGE AND INTAKE OF AIR HANDLING UNITS. INCREASE DUCT SIZED INDICATED ON PLANS MODIFICATIONS TO LANDLORD PROVIDED SYSTEM. FILTERS LOCK-SEAM TYPE, AS SHOWN ON HVAC PLAN SHEET M2.0. ASSEMBLE AND INSTALL DUCTWORK IN AS NEEDED IN EACH DIMENSION TO ACCOMMODATE LINER. LINER SHALL BE FASTENED TO SUPPLY DIFFUSER PROVIDE THREE (3) SETS OF PLEATED DISPOSABLE FILTERS. USE ONE SET UNTIL COMPLETION ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGNT (5%LEAKAGE) AND DUCT WITH MECHANICAL LINER FASTENERS IN ACCORDANCE WITH SMAGNA. z, THIS CONTRACTOR SHALL MODIFY EXISTING UPRIGHT SPRINKLER NEAD IN DROP � � OF CONSTRUCTION. INSTALL ONE SET AT COMPLETION OF CONSTRUCTION AND DELIVER ONE NOISELESS {NO OBJECTIONABLE NOISE SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SET OF FILTERS TO POTBELLY LABELED TO DENOTE THEIR RESPECTIVE AIR HANDLWG UNIT. SERVICE. FURNISH ALL REQUIRED DAMPERS, TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND ALL NEW SUPPLY, RETURN AND OUTSIDE AIR RECTANGULAR/SQUARE DUCTWORK SHALL BE CEILING(PLASTER) LOCATIONS TO FULLY RECESSED SPRWKLER HEADS. RELOCATE / FILTERS TO BE FARR, OR SIMILAR. OTHER ACCESSORIES NECESSARY FOR A COMPLETE OPERATING SYSTEM. NO VARIATION OF DUCT INSULATED WITH 1" THICK, 2 PCF DUCT LINER. DUCT LINER SHALL BE FASTENED TO INSIDE OF UPRIGHT HEADS IN OPEN CEILING AREA TO MAINTAIN FULL AREA COVERAGE. / RETURN GRILLE CONFIGURATION OR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION FROM THE ENGMEER. DUCTWORKAS PER MANUFACTURER'S DIRECTIONS AND S.M.A.GN.A. "DUCT LINER � MOUNT DUCTWORK AS HIGH AS POSSIBLE TO UNDERSIDE OF STRUCTURE. (NO SQUARE THROAT APPLICATION STANDARD". ALL NEW SUPPLY, RETURN AND OUTSIDE AIR ROUND/OVAL 3. THIS CONTRACTOR SHALL PROVIDE PERMITTING FOR FINAL HYDRAULIC CALCULATIONS EXHAUST FANS ELBOWS SHALL BE INSTALLED WITHOUT DOUBLE THICKNESS TURNWG VANES.) ALL DUCT DUCTWORK , WHICH ARE NOT LINED, SHALL BE INSULATED WITH t-0/2" THICK FLEXIBLE AND HEAD LOCATIONS BASED UPON FINAL DESIGN BY CONTR4CTOR AND SUBMIT TO PROVIDED TO THE SITE BY VENDOR. THE MECHANICAL CONTR4CTOR IS RESPONSIBLE FOR CONNECTIONS TO EQUIPMENT SHALL BE LOADED TYPE VINYL, VIBR4TION ELIMINATION INSULATION,1 PCF DENSITY FOIL REINFORCED KRAFT FACING. DUCT WRAP SHALL BE LOCAL OR STATE BUILDING DEPARTMENT AS REQUIRED FOR APPROVAL. �\/ COORDINATING DISCHARGE LOCATION WITH NEW AND EXISTING VENTS AND INTAKES, CONNECTIONS, (F.C.) FLEXIBLE CONNECTIONS. DUCTWORK TRANSITIONS SHALL BE (FOT) "FLAT ON FASTENED TO DUCTWORK AS PER MANl1FACTURER'S DIRECTIONS. THE ROUND BRANCH Y EXHAUST GRILLE PROVIDING COMPLETE INSTALLATION INCLUDING CURBS, BACKDRAFT, DAMPERAND TOP' UNLESS OTHERWISE SPECIFIED ON PLAN. ALL BRANCH SUPPLY DUCTS SHALL HAVE (VD) MANUAL DUCTWORK SHALL BE INSULATED WITH P' THICK FIBERGLASS SLEEVE WITH FOIL JACKET AND 4. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL DUCTWORK FROM RESTROOM GRILLE TO UNIT AND NECESSARY ACCESSORIES, AND VOLUME DAMPERS INSTALLED FOR BALANCING� SEE SYMBOL LIST. ALL ROOF PENETRATIONS AlL JOINTS AND TERMINATIONS SEALED WITH FOIL OR DUCT TAPE. ROUND/OVAL SUPPLY AND CODES AND ORDINANCES. PROVIDING WARRANTY. EXHAUST FAN(S) TO BE OPERATED "IN CONJUNCTION WITH AIR EXCEEDING 12" X 12" IN SIZE SHALL BE FURNISHED WITH BURGLAR BARS. ALL CONTRACTOR RETURN DUCTWORK EXPOSED TO VIEW AND LOCATED IN THE CONDITIONED SPACE SHALL - 0 T D TO AVOID CONFLICTS WITH NEW AND EXISTING NOT BE INSULATED. EXTERIOR DUCTWORK TO E 1-1 2" 5. SPRINKLER PIPING SNALL BE R U E HANDLING UNIT S. ROUTE FAN WIRING VIA FAN CONTROL RELAY TO BE INTERLOCKED WITH FABRICATED AN B / LINED AND WEATHERPROOFED. DUCTS O D MANUFACTURER FABRICATED CAMPONENTS OP THE OUTSIDE AIR, SUPPLY AIR, TO BE LINED: DUCTWORK, PIPING CONDUITS AND LIGHTING LAYOUT. O O THERMOSTAT 1 SENSOR PROGR4MMABLE THERMOSTAT. PROVIDE CONTROL RELAY (HONEYWELL R8222 OR RETURN AIRAND EXHAUST SYSTEMS SHALL BE CONSTRUCTED AND INSTALLED AIR-TIGHT. THE / EQUIVALENT) AND 24VAC CONTROL POWER SUPPLY WITH OVERLOAD PROTECTION. INSTALL INSTALLED SYSTEMS SHALL BE PRESSURE TESTED AS SPECIFlED. PIPE OPENINGS IN SYSTEM a.) ALL RECTANGULAR CONCEALED AND EXPOSED SUPPLY DUC'fWORK. POWER SUPPLY (GENSCO #MAR2402�XFMR OR EQ) AND FAN CONTROL RELAY ADJACENT TO COMPONENT SHALL HAVE SHEET METAL BAFFLES, SET IN SEALANT, TO PREVENT LEAKAGE. ALL DUCT b.) ALL RETURN DUCT WORK FROM GRILLES TO ROOFTOP UNITS 6. SPRINKLER CONTR4CTOR SHALL OBTAIN DUCTWORK SHOP DRAWING FROM HVAC ONE ANOTHER IN ACCESSIBLE CEILWG SPACE AND EXTEND LOW VOLTAGE WIRING BETWEEN DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR OUTSIDE DIMENSIONS. c.) ALL EXHAUST DUCT RISERS TO ROOF FANS AND FOR A DISTANCE OF 5'-0' FROM CONTR4CTOR AND COORDINATE ROUTWG OF SPRINKLER PIPING. ANY RELOCATION RECTANGULAR OR ROUND SUPPLY OR AUXILIARY RELAY PROVIDED WITH PROGRAMMABLE THERMOSTAT AND FAN CONTROLRELAY. VERTICAL DUCT CONNECTION. REQUIRED BY SPRINKLER CONTRACTOR'S FAILURE TO COORDINATE SHALL BE DONE AT RETURN DUCT (AS NOTED) COORDINATE ALL REQUIREMENTS WITH MECHANICAL CONTRACTOR. d.) ANY OTHER DUCTWORK SPECIFICALLY NOTED ON THE CONTRACT DRAWINGS. NO EXTR4 COST OR DELAY TO THE OWNER. GENERAL CONTRACTOR TO COORDINATE. DUCT SEALANT ALL FLEXIBLE DUCTWORK SHALL BE FACTORY ASSEMBLED CLASS 1 AIR DUCT (UL 181) WITH 7. FINAL CONSTRUCTION DOCUMENTS, HYDRAULIC CALCULATIONS AND PERMITTING T_ SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS +MTH A NON-HARDENWG, NONMIGRATING FIBERGLASS INSULATION AND REINFORCED OUTER PROTECTNE COVERNAPOR BARRIER. SHALL BE BY THE SPRINKLER CONTRACTOR. � MANUAL BALANCE DAMPER MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR FLEX DUCT SHALL MEET NFPA 90A WITN FLAME SPREAD UNDER 25, SMOKE DEVELOPED UNDER SEALING JOINTS AND SEAMS IN SHEET METAL DUCTWORK. COVER ALL FIELD JOINTS, JOINTS 50, AND SHALL BE RATED FOR 2" W.C. PRESSURE AND 0 TO 250 DEGREE TEMPERATURE. 8. IF REQUIRED: INSTALL INSPECTOR TEST CONNECTIONS PIPED TO FUNNEL DRAIN OR �- AROUND SPIN-IN FITTWGS AND FASTENING SCREWS WITH MASTIC. MAXIMUM STRETCHED OUT LENGTH SHALI BE 6'-0". MOP SINK. �- RECTANGULAR TAKE-OFF FROM 9. ONLY ONE CONNECTION SHALL BE MADE TO MALL SPRINKLER MAIN. FIELD VERIFY SUPPORTS DAMPER CONTROL RECTANGULAR DUCT WITH BALANCE EXACT LOCATION. X PROVIDE HOT-DIPPED GALVANIZED STEEL, FASTENERS; ANCHORS. RODS, STRAPS, TRIM, AND CONTRACTOR TO ENSURE THAT ALL ELECTRICAL CONNECTIONS TO MECHANICAL DAMPERS DAMPER ANGLES FOR SUPPORT OF DUCTWORK. ARE CONNECTED. 10. IF REQUIRED: TENANT SPRINKLER SYSTEM SHUT-OFF VALVE AND VALVE TAMPER � DAMPERS SWITCH TO FURNISHED AND INSTALLED BY SPRINKLER CONTRACTOR. ROUND TAKE-OFF FROM DUCT PROVIDE OPPOSED-BLADE, MULTI-LEAF VOLUME CONTROL DAMPERS WHERE INDICATED ON WITH MANUAL BALANGE DAMPER DRAWINGS AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN AND EXHAUST DUCTS t t. SPRINKLER CONTR4CTOR SHALL PERFORM ALL WORK PER LANDLORD'S CRITERIA WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIDE UL LISTED AND FIRE/SMOKE 12. AlL WORK TO BE APPROVED BY LOCAL FIRE DEPARTMENT. SUBMIT SHOP DRAWINGS I � DAMPERS WHERE REQUIRED AND IN ACCORDANCE WITH NFPA AND LOCAL CODES. PROVIDE FOR APPROVAL TO ENGINEER, TENANT, AND LOCAL FIRE DEPARTMENT. �� TURNING VANES CONVENIENTLY LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING THE � DAMPERS. INSTALL PER UL GUIDELINES. � 13. A�L PERMITS FEES ETC. BY CONTRACTOR. GRILLES, REGISTERS & DIFFUSERS �DEVICE GRILLES, REGISTERS AND DIFFUSERS SHALL BE MANUFACTURED BY TITUS AND SHALL BE GC 14. A PIRE PROTECTION ENGINEER TO PREPARE SET OF CERTIFIED STAMPED SHOP AIR DEVICE DESIGNATION DRAwINGS OF DESIGN. TYPE SUPPLIED (UON). DIFFUSERS IN METAL PANEL CEILING TO BE ORDERED IN SILVER MILL FINISH. 600 SEE SHEET M3.0 DIFFUSERS SHALL BE INSTALI.ED AS INDICATEO ON THE DRAIMNGS AND SCHEDULES. THE CFM MECHANICAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS ITEMS NECESSARY FOR A 15. ALL SPRINKLER HEADS TO BE QUICK RESPONSE TYPE. COMPLETE AND PROPER INSTALLATION IN THE TYPE OF CEILWG AND WALLS USED IN THIS RT E�YQPE MENT PROJECL 16. PROVIDE METAL CAGE OVER ALL SPRINKLERS IN COOLER ( FREEZER. soo EQUIPMENT DESIGNATION DESIGNATION SEE SHEET M3.0 THERMAL INSULATION NUMBER PROVIDE EXTERNAL THERMAL INSULATION WITH AN INTEGRAL VAPOR BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL ENERGY CODE REQUIREMENTS. PROVIDE INSULATION B.O.D. BOTTOM OF DUCT ON EXHAUST AND OUTSIDE AIR DUCTS, AND ON CONCEALED PORTIONS OF SUPPLY AND RETURN AIR DUCTS. DO NOT INSULATE EXPOSED DUCTWORK AND PORTIONS OF DUCTWORK THAT ARE WTERNALLY LINED. THERMAL WSULATION TO COMPLY WITH AN NFPA FLAME SPREAD OF 25 OR LESS, AND SMOKE DEVELOPED NO GREATER THAN 50. .. � � i � � . . � . � � ;-� SPLITTER DAMPER UCD UNDERCUTDOOR MD MOTORIZED DAMPER THERMOSTAT: WALK IN FREEZER/COOLER: CONTROL WIRING COOLER INFORMATION 1. THE HVAC CONTRACTOR SHALL INSTALL HVAC SYSTEMS AS SHOWN, NOTED AND 10. SCOPE THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROL WIRING IN CONDUIT THE VOLUME OF THE COOLER IS 541.3 CUBIC FEET. THE COOLER USES 2.9 POUNDS R-22 SPECIFIED. EQUIPMENT MAY NOT BE SUBSTITUTED UNLESS WRITTEN APPROVAL BY THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE NECESSARY FOR THE COMPLETE AND PROPER OPERATING TEMPERATURE CONTROL SYSTEM. REFRIGERANT. THE COOLER HAS A 1 HP MOTORAND THE COMPRESSOR IS A SELF CONTAINED UNIT THE ARCHITECT, ENGINEER, OR OWNER'S REPRESENTATIVE IS OBTAINED. ANY AND FULIY OPERATIONAL MECHANICAL SYSTEM. THE CONTRACTOR SHALL FURNISH THAT IS MOUNTED ON TOP OF THE UNIL CHANGES TO THE DUCTWORK LAYOUT WILL NECESSITATE SUBMISSION OF SHEET ALL LABOR, MATERIAL AND EQUIPMENT RELATED TO THE INSTALLATION OF THE THERMOSTAT METAL SHOP DR4WINGS FOR ENGINEER'S REVIEW. ANY UNAUTHORIZED CHANGES WILL MECHANICAL WORK. THERMOSTAT(S) SHALL BE PROGR4MMABLE ZONE SENSOR, ITEM #IKT7351 F212Z (1) TO BE FREEZER INFORMATION BE REMOVED AT CONTRACTOR'S fXPENSE, IF DEEMED NECESSARY BY ARCHITECT, PROVIDED PER HVAC UNIT. MULTISTAGE SEVEN DAY PROGRAMMABLE THERMOSTAT. THE VOLUME OF THE FREEZER IS 230A CUBIC FEET. THE FREEZER USES 3.5 POUNDS R-404a ENGINEER, OR OWNER'S REPRESENTATIVE. 1 L SITE EXAMINATION REMOTE SENSOR(S) SHALL BE HONEYWELL, ITEM #TR21-A.(2) PER HVAC UNIL REFRIGERANT. THE FREEZER HAS A 1.5 HP MOTOR AND THE COMPRESSOR IS A SELF CONTAINED UNIT THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, IF PSW IS PROVIDING THE HVAC UNITS, TRANE IS TO COORDINATE AND SHIP THE THAT IS MOUNTED ON TOP OF THE UNIT. 2. THE HVAC CONTRACTOR SHALL COORDINATE DUCTWORK INSTALLATION WITH DUCTWORK, AND PIPING WILL BE INSTALIED AND WILL REPORT ANY CONDITION THAT, W THERMOSTAT/SENSORS AND G.C. IS TO INSTALL. IF PSW IS NOT PROVIDING THE HVAC UNITS, ARCHITECT/OWNER'S REPRESENTATIVE IN FIELD AND OTHER TRADES. SEE HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE MECHANICAL WORK. THE G.C. WILL PURCHASE, SUPPLY AND INSTALL THE THERMOSTAT/SENSORS. ONE ARCHITECTUR4LDRAWINGS FOR EXACT LOCATION AND HEIGHTS. THERMOSTAT AND TWO REMOTE SENSORS TO BE PROVIDED FOR EACN HVAC UNIT. MOUNT 12. STANDARDS THERMOSTAT(S) INSIDE MANAGERS DESK CUBBY AREA UNLESS OTHERWISE NOTED. 3. ALL DUCTWORK AND PIPING SHALI BE ROUTED ABOVE THE SUSPENDED CEILING SPACE EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL, MECHANICAL CONTRACTOR TO PROVIDE THERMOSTAT IDENTIFICATION WITH g° HIGH WHITE UNLESS OTHERIMSE NOTED ON THE PLANS. ASME, ASTM, UL, NEMA, ANSI, SMACNA, ASHRAE, NFPA, AS APPLICABLE TO EACH LETTERS ON KELLY GREEN OR BLACK PHENOLIC LABELS BACKGROUND, I.E. °AG1 : CUSTOMER INDIVIDUAL UNIT OR ASSEMBLY. AREA" AND "AG2 : WORK AREA". REFER TO THERMOSTAT SETUP INSTRUCTIONS BELOW FOR 4. ALL OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 10'-0" AWAY FROM EXHAUST ADDITIONAL REQUIREMENTS DISCHARGE OPENINGS AND PLUMBWG VENT STACKS, AND MINIMUM 10' ABOVE GRADE. 13. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE 5. CORE-DRILL OR SAW-CUT EXISTWG WALLS, ROOF, ETC. AS REQUIRED FOR PIPING OR AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DUCTWORK AND FIRE-STOP OPENING AROUND PIPE OR DUCTWORK. VERIFY LOCATION DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST THERMOSTAT SETUP WSTRUCTIONS OF STRUCTURAL BEAMS, JOISTS, ETC. BEFORE DRILLWG OR CUTTING. NOTIFY STANDARD SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE PROVIDE THE FOLLOWING SETUP AND PROGRAMMING ON THE THERMOSTAT. ARCHITECT OF ANY DISCREPANCIES. REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO POTBELLY. t. MSTALL PER MANUFACTURER'S IOM. 6. WHEREVER FOUNDATION WALLS, OUTSIDE WALLS, ROOFS, ETC. ARE CUT FOR 14. PERMITS AND FEES 2. SET DIP SWITCHES AND JUMPERS AS FOLLOWS: INSTALLATION OF SYSTEMS, THEY SHALL BE PATCHED TO MATCH EXISTING THE CONTRACTOR SHAIL PROCURE AND PAY FOR ALL PERMITS, FEES AND A) DEGREES F DISPLAY CONSTRUCTION AND SEALED WEATHER TIGHT. WORK SHALL BE PERFORMED BY INSPECTIONS NECESSARY TO COMPLETE THE MECNANICAL WORK. B) 12 HOUR CLOCK CRAFTSMEN SKILLED IN THEIR RESPECTIVE TR4DES. C) CONTINUOUS FAN OPERATION IN OCCUPIED MODE 15. WARRANTY D) DISABLE KEYBOARD PROGRAMMING 7. THE MECHANICAL SYSTEMS SHALL BE COMPLETE WITH ALL NECESSARY THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF E) CUT JUMPER IF UNIT IS A HEAT PUMP APPURTENANCES FOR A COMPLETE OPERATING SYSTEM. DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (i) YEAR FROM THE 3. SET CLOCK AND DAY. DATE OF FINAL ACCEPTANCE BY POTBELLY AND WILL REPAIR OR REPLACE ANY 4. SET TO DISPLAY CURRENT TEMPERATURE. 8. AN INDEPENDENT AIR BALANCE CONTRACTOR SHALL ACCURATELY BALANCE THE AIR DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER 5. START TIMES OF UNITS SHOULD BE STAGGERED IN 15 MINUTE INTERVALS TO AVOID SYSTEMS TO PROVIDE AIR INDICATED ON THE DRAWINGS AND IN THIS SPECIFICATION. EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTNE MATERIALS AND HIGH SPIKE USAGE, WHICH RESULTS IN A HIGHER KW CHARG TO US BY UTILITY COMPANY. OPER4TE AUTOMATIC CONTROLS SYSTEM AND VERIFY SET POINTS. A NEBB OR AABE WORKMANSHIP. STANDARD SET POINT SHOULD BE 6AM & 6:15 AM FOR NON-BREAKFASTtOCATIONS. CERTIFIED SUPERVISOR SHALL BE IN CHARGE OF WORK. SUBMIT TWO (2) COPIES OF BREAKFAST LOCATIONS SHOUID HAVE START TIMES OF 5AM & 5:15AM. SET UNOCCUPIED TNE BALANCE REPORT TO THE ENGINEER FOR APPROVAL. INCLUDE A COPY OF THE 16. CONTRACTOR SHALL COORDINATE WITH LANDLORD FOR ALL ROOF PENETRATIONS, START TIME AT 1 HOUR AFTER CLOSING. VERIFY HOURS WITH STORE MANAGER OR BALANCE REPORT AS APPROVED BY THE ENGINEER WITH APPLICATION FOR FINAL UTILIZE LANDLORD ROOFING CONTRACTOR AT TENANTS EXPENSE FOR ROOF CONSTRUCTION MANAGER. THESE SET POINTSCAN BE SET AT THE SAME TIME FRAME. NO CONTRACT PAYMENL PENETR4TIONS TO MAINTAIN ANY APPLICABLE ROOF WARRANTIES. NEED TO STAGGER. 6. SETPOINTS SHALL BE AS FOLLOWS: 9. THIS CONTR4CTOR SHALL OBTAIN A COPY OF THE WORK LETTER FROM THE PSW OCCUPIED UNOCCUPIED CONSTRUCTION MANAGER PRIOR TO SUBMISSION OF THE BID. THIS CONTRACTOR HEATING 68deg F 60deg F SHALL SUBMIT SAID WORKLETTER AS EVIDENCE OP HAVING REVIEWED CONTRACTORS COOLWG 70deg F 85deg F RESPONSIBILITIES WITHIN SCOPE OF WORK. ANY DISCREPANCIES BETWEEN THE WORKLETTER AND THE DESIGN DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE PSW CONSTRUCTION MANAGER, BEfORE BID DUE DATE. &: �Ytl'� � �l',"i[�/'s�'f � [+l;i'�d 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 NNNN.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 94311 330.572.2100 Fax: 330.572.2702 � r w � � Q ��/ L.I..� J N J M � O � J ( � � °° W � � Z �' � � z W U � W � C � � � G � � � � w z �- Q � � U a eaa��ervean�oonen>r�o ,0/ c''���G S S� �,���'P. ','7�, ,c< < _, • t�"s ' No.193ce5en - (� �� �......___..._...�- ; €3 :. .o �. S7ATc CF ; � ? �'P�,c•� /NDIANP.° ���.` o%. P ' �` '° °;,,SS/O N A'� E�..d"y�` �I / SHEET TITLE MECHANICAL LEGEND & NOTES SHEET NUMBER M1.0 � MECHANICAL P NORTH C� SCALE: 1 /4"=1'-0" KEYNOTES OTHERMOSTAT INSTALL THERMOSTAT AND AVERAGING REMOTE SENSORS AS SHOWN. COORDINATE EXACT LOCATION WITH OWNER REP. MOUNT T-STATS AS INDICATED ON DWGS. MOUNT SENSORS AT 60" A.F.F. U.N.O. IN LOCKABLE ENCLOSURE. COORDINATE WITH ELECTRICAL CONTR4CTOR FOR BACKBOX. CONTRACTOR TO VERIFY COMPATIBILITY AND WIRE T-STATS AND SENSORS TO HVAC UNITS. OSEE SUBMARINE DETAIL DRAWING 10/M4.0. SEE ARCHITECTURAL DRAWINGS FOR SUBMARINE HANGING INSTRUCTIONS. 24 HOURS PRIOR TO INSTALLATION CONTRACTOR SHALL CONTACT OWNERS PROJECT MANAGER FOR EXACT INSTALLATION ANGLES. OPROVIDE MANUAL VOLUME DAMPER TO AIR DEVICE. OPROVIDE SMOKE DETECTOR IN MAIN SUPPLYAND/OR RETURN DUCT OF EACH RTU WHICH WILL DE-ENERGIZE THE UNIT UPON SMOKE DETECTION. INTERLOCK WITH FIRE ALARM SYSTEM IF APPLICABLE. VERIFY ALL REQUIREMENTS WITH LOCAL CODES & LANDLORD. ORTU-1 & RTU-2 2 ROOFTOP UNITS FURNISHED & INSTALLED BY LANDLORD. BALANCE SUPPLY, RETURN AND OUTDOOR AIR FLOWS PER SCHEDULE ON SHEET M3.0. PROVIDE WITN 3 SETS OF FILTERS FOR EACH UNIT - ONE SET FOR USE DURING CONSTRUCTION, ONE SET INSTALLED AT COMPLETION OF CONSTRUCTION AND ONE SPARE SET FOR TENANT. OEF 1 EXHAUST FAN & KITCHEN EXHAUST HOODS FURNISHED BY PSW & INSTALLED BY CONTR4CTOR. CONTRACTOR TO MAKE ALL CONNECTIONS BETWEEN HOODS AND EXHAUST FAN. CONTRACTOR RESPONSIBLE FOR COORDINATION BETWEEN LANDLORD AND ROOFING CONTRACTOR. OROUTE 24"0 SUPPLY AND 32"x16" RETURN DUCT UP TO RTU-1. DUCT CONNECTIONS TO RTUS SHALL BE MADE FULL SIZE OF EQUIPMENT OPENING WITH FLEXIBLE DUCT CONNECTIONS AT UNIT AND THEN TRANSITION TO THE SIZES SHOWN. O$ INSTALL TOP OF DUCTWORK TIGHT TO BOTTOM OF STRUCTURE. OEXHAUST HOOD PROVIDED BY OTHERS. CONNECT TO EXHAUST GRILLE TO TOP COLLAR. PROVIDE NECESSARY TRANSITION. SEE DETAIL 3/M4.0. 1 O 18" DIA. EXHAUST DUCT UP TO ROOF MOUNTED EXHAUST FAN EF-1, TRANSITION TO EXHAUST FAN, FIELD VERIFY EXACT REQUIREMENTS. EXHAUST DUCT TO COMPLY WITH TYPE II DUCT REQUIREMENTS. 11 12 12" DIA. EXHAUST DUCT UP FROM EXHAUST HOOD WITH VOLUME DAMPER. EXHAUST DUCT TO COMPLY WITH TYPE II DUCT REQUIREMENTS. 8"x8" EXHAUST DUCT UP TO ROOF MOUNTED EXHAUST FAN EF-2, TRANSITION TO EXHAUST FAN, FlELD VERIFY EXACT REQUIREPAENTS. 13 EF-2 EXHAUST FAN FURNISHED BY PSW & INSTALLED BY CONTRACTOR. CONTRACTOR TO MAKE ALL CONNECTIONS BETWEEN GRILLES AND EXHAUST FAN. CONTRACTOR RESPONSIBLE FOR COORDINATION BETWEEN LANDLORD AND ROOFING CONTRACTOR. 14 ROUTE 3" DIA. COMBUSTION AIR INTAKE AND 3" DIA. FLUE DUCT UP TO CEILING SPACE FROM WATER HEATER. EXTEND IN CEILING SPACE AS SHOWN. 15 ROUTE 32"x18" SUPPLY AND 32"x16" RETURN DUCT UP TO RTU-2. DUCT CONNECTIONS TO RTUS SHALL BE MADE FULL SIZE OF EQUIPMENT OPENING WITH FLEXIBLE DUCT CONNECTIONS AT UNIT AND THEN TRANSITION TO THE SIZES SHOWN. 16 ROUTE 3" DIA. COMBUSTION AIR INTAKE AND 3" DIA. FLUE UP THROUGH THE ROOF AND TERMINATE WITH ROOF/RAIN CAP PER THE MANUFACTURER'S RECOMMENDATION. COORDINATE ROOF PENETRATION WITH LANDLORD'S ROOFING CONTRACTOR. � ,� t-=-t A � : i, ; 222 MERCHANDISE MART PLAZP„ SUITE 23�0 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /�e_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 N M �Y � Z J �C.�..� G � Q U M � u� 0 � 0 N � w m � 7 Z H � w 0 � a �caaa nn rnipsr ,�'°���`� -�- SC'yi,c°m �`4Q'.�G\STERF, ��% c �,�� p',� -e = No.�930090A " - � � ._�_______._e ; � - = -o �� STAT� OF ; �r � a-� `, , � . ',�,c'�.�NDIoNP.•"��.z � '���'�,SS�GNALf.:�Cu°`�!// � 1 /g/l� SHEETTITLE MECHANICAL PLAN SHEET NUMBER M2.0 VENTILATION SCHEDULE INDIANAMECHANICAL . � CODE, 2014 TABLE 403.3 AREA � OCCUPANCY ,SQ�) � CODE REQUIREMENT REQUIRED VENTILATION � ACTUAL PROVIDED DINING FAST FOOD '1085 i0.18�CFM/SQFT+7,5 CFMlPERSON�/0.8 695 CFM � MENS � TOILET ROOMS 65 50 CFM EXHAUST PER FIXTURE � 50 CFM EXHAUST WOMENS� TOILET ROOMS 65 50 CFM EXHAUST PER FIXTURE 50 CFM EXHAUST 1950 CFM TOTAL O.A. 1700 CFM EXHAUST FOR KITCHEN PREP ROOM �� KITCHEN 285 0.7 CFM EXHAUST/SQ FT 200 CFM EXHAUST 150 CFM EXHAUST FOR BOTH � � SERVICE LINE KITCHEN 340 � 0.7 CFM EXHAUSTlSQ FT 238 CFM EXHAUST RESTROOMS . CORRIDOR . CORRIDOR � 110 (0.06 CFM/SQFT�10.8 9 CFM � � � � � TOTAL: 704 CFM O.A AND 538 CFM EXHAUST � NOTES: 1. TRANSFER GRILLES ARE PROVIDED TO ALLOW FREE FLOW OF AIR FROM PREP ROOM TO SERVICE LINE. 2. SERVICE LINE AND DINING AREA ARE OPEN SPACES THAT ALLOW AIR TO TR4NSFER FREELY. 3. 75 CFM EXHAUST FOR WOMEN'S AND 75 CFM EXHAUST FOR MEN'S IS PROVIDED IN RESTROOMS, DOOR ARE TO BE UNDERCUT 3/4" TO ALLOW TRANSFERAIR WHILE MAINTAINING RESTROOMS AT NEGATIVE PRESSURE. 4. ALL VENTILATION AIR IS PROVIDED THROUGH THE ROOFTOP UNITS AIR SUPPLY. AIR BALANCE SCHEDULE TAG . OUTSIDE AIR RETURN AIR � SUPPLY AIR EXHAUST AIR PRESSURE � PERCENT OUTSIDE AIR RTU-1 � 850 2550 3400 0 +850 25.0°k RTU-2 � �� 1100 2300 3400 0 +1100 32.3°k EF-7 0 0 0 1,700 -�,700 � EF-2 0 0 0 � � 150 -150 -- � TOTAL: � . +100 FAN SCHEDULE . MARK � CFM S.P. VOLTSIPHASE FAN HP AREA SERVED MANUFACTURERIMODEL WEIGHT NOTES . � EF-1 1700 .75" 208 3/4 KH-0 8 KH-2 GREASE MASTER 150 UL 762 FAN MOTOR COVER, OS, . 3 GM14•FA SPRING ISOLATORS, BDD, BS EF-2 � �150 .375" 115 7/8 � TOILET ROOMS GREASE MASTER . � GMDRIOH 59 DS,BDD NOTES: BOD = BACKDRAPT DAMPER SCR = SPEED CONTROL SI = SIDE INLET � BS = BIRDSCREEN � SD = SIDE DISCHARGE SIT = SIDE INLET TRANSITION DOP = DOWN DISCHARGE PLENUM DS = NON-FUSED SERVICE DISCONNECT WD = WEATHER HOOD DIT = DUCT INLET TRANSITION EC = EPDXY COATING PE = PREMIUM EFPICIENCY MOTOR � � � MEP= MASTER ELECTRIC PANEL � FILT = PERMANENT FILT. � � RC = ROOF CURB GB = GREASEBOX AIR DEVICE SCHEDULE MARK QTY ECT. NECK SIZE ROUS ZEECK FACE SIZE PAnERN MOUNTING ANUFACTURERIMODE NOTES � A 10 12X6" - 14X9" DUCT METALAIRE 4004P-1 TO BE USED AT All EXPOSED SPIRAL DUCT VISIBLE TO CUSTOMERS. B 6 - 10" DIA 24X24" 4-WAY LAY-IN TITUS TMS 2 C 3 - B" DIA 12X12" 2-WAY CEILING TITUS TDC 2 � D 2 - 18"DIA 24X24" RETURN LAY-IN TITUS 355RL E 2 - B" DIA 12X12" EXHAUST CEILING TITUS 355RL � F 1 42X24" - 44X26"� RETURN SURFACE TITUS 300RL GENERAL NOTES: � A. DEVICES SHALL BE WHITE FROM THE MANUFACTURER AND PAINT TO MATCH CEILING OR WALL. B. DEVICES SHALL BE SILVER MILL FINISH FROM THE MANUFACTURER WHEN IN METAL PANEL CEILING SYSTEM. C. ALL DEVICES SHALL BE 4-WAY UNLESS SHOWN OTHERWISE � D. CONTRACTOR IS RESPONSIBLE FOR VERIFING QUANTITIES AS SHOWN ON PLANS. NOTES: � PROVIDE WITH GRILLE COVER. GRILLE COVER TO BE MCNICHOLS DECORATIVE METAL. CLOVER LEAf PATTERN TO MATCH CEILINGIWALL WITH HOOD, STAINED ST-4, MCNICHOLS PH. NO. 877-684�653. � 2• PROVIDE WITH DAMPER (AG-35) � ROOFTOP UNIT SCHEDULE HEATING COOLING TAG MANUF/ MODEL CFM OA. CFM E.S.P. VOLTS/ FAN HP MCA/MOCP EER/SEER WEIGHT REMARKS PHASE INPUT OUTPUT NOM. TOTAL SENS. ENT. ENT. MBH MBH TONS MBH MBH D.B. W.B. RTU-1 TRANE YSG1�2F3 3400 850 1,0" 208 2 � 43.3 112 200 160 8.5 102 77.0 80°F 67'F 12W 1, 2, 3, 4 3 50.0 - RTU-2 TRANE YSC102F3 3400 1100 1.0" z08 2 � 43.3 11.2 qq0 160 8.5 102 77.0 80°F 67°F 1200 1, 2, 3, 4 3 50.0 - NOTES: 1. ROOFTOP UNITS FURNISHED AND INSTALLED BY LANDLORD. 2. INSTALL DUCT SMOKE DETECTORS, FIELD INSTALLED AS SHOWN ON PLANS. RTU SHALL SHUTDOWN AND SIGNAL FIRE ALARM SYSTEM pF APPLICABLE) WHEN ACTIVATED. 3. UNITS PROVIDED WITH ROOF CURB, FULL ECONOMIZER CYCLE DAMPERS, BAROMETRIC RELIEF AND CONTROLS. 4. UNITS PROVIDED WITH EXPANDED METAL HAIL GUARDS. TYPE II EXHAUST HOOD SCHEDULE � EXHAUST PLENUM � � � TAG MANUF / MODEL HOOD SIZE � TOTAL RISER(S) HOOD WEIGHT FANHOOD'NG HOOD CONSTRUCTION REMARKS EXH. CFM yy�DTH LENGTH DIAMETER CFM S.R � KH-1 GREASEMASTER 5'-0" L X 3'-0" 850 - - 12" 850 -0.109 136 LBS EF-1 430 SS WHERE � 3624 GC-1 EXPOSED � KH-2 GREASEMASTER 5'-0" L X 3'-0" 850 - - 12" 850 A.109 136 LBS EF-1 430 SS WHERE � 3624 GC4 � EXPOSED NOTES: 1. EXHAUST FANS & KITCHEN HOODS PROVIDED BY PSW VENDOR AND INSTALLED BY CONTR4CTOR. SAPI'D'IIXIC/: SMiii'x�, 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P:312.951.0600 F:312.951.0300 NNWJ.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 � Akron, OH 44311 330.572.2100 Fax: 33U.572.2102 � r �.�..� � '�^ VJ � � O � � N � M � � � � � � � � � WC J � G ` � o � � � Q � J m U C� W � 1 � � H N � W Z � Q o�c � - � U �. ISSUE DATE ISSUE DATE DD SET 11,20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 eoo�iaoeau�nqi.�p 9` ,o nE J. S C a.< ;° 0�,.•---••;yr.c'� p�'�Q-,' G1STE,Q' . �`�''s ; �;"�.� F�.� � ' No_1�300�04 - " 6 �� _______,__�___� ; &8 " =� ��• STATE Or : � e ' ti e %�,��� �NDIANP-'���`�` ��'°��S�O N AL E�� ,', '��//dI/II .�e`�1 l/S/t� SHEET TITLE MECHANICAL SCHEDULES SHEET NUMBER M3.0 � , LIQUID RECEIVER NOTE: DIVE TO 20 DEGREE CANT. 24 HOURS PRIOR TO INSTALLATION CONTRACTOR TRAPEZE HANGERS / SHALL CONTACT OWNER'S PROJECT MANAGER FOR EXACT INSTALLATION 3"- ELBOW -� ANGLES. PROPELLAR TO SPIN FREELY WITH AIR FLOW. RELIEHSAFETY �qp 10"- TO 6"- TALL STRAPORANGLE � ROD VALVE CONDENSING CONE NAILER � �, �;I UNIT � i; I, �' I 6"-T02-1l2"Xt2" � 12"-SPIRALDUCT � i'; ' �i HORNB00T 1"WIDE;18 GA. � 2 1/2°X12" REG. �— � SUPPORTSTRAPwI i�01ST TAPERED ��- �' � 6"-T02-1/2"X12"HORN SIZE 80LT(S) — SUCTION LINE, 5/8" O.D. "K" BOOT 5'-0"MAXIMUM - ROUND RIGID DUCT FOR LOAD COPPER 12°- T0 8"- TALL— SPAqNG � STRAP NANGERS CONE �LIQUID LINE, 3/8" O.D. "K" i � � � UNLESS FOOT OF \ COPPER PROPELLER HANGER STRAPS STRAP IS PLACED UNDER A BOTTOM � �� �i REINFORCEMENT ��PANSION � �'I e ' '� VALVE 1/2" HOLES DRILLED ---I (EXPOSED DUCTWORK ONLY� USE RECTANGULFIR ' i� NOTES: 1.REMOVEEXPANSIONVALVES,DEVICESANDCONNECTIONSFROM INTOCOVER 2-1/2"X12"REG. CONTINUOUSHANGER UNITCOOLER THEAIRSTREAM. „ TAPERED DUCT IF ABOVE CEILING) STRAPAROUNDDUCT (EVAPORATORCOIL) 2.WSTALLPRESSURERELIEFVALVEONHIGHPRESSURESIDEOF ,� SYSTEM, UPSTREAM FROM ANY LIQUID LINE SHUT-OFf VALVES. 3. REPRIGERATION PIPING TO BE TYPE'K' COPPER. 4. ALL REFRIGER4TION PIPING JOINTS TO BE BRAZED. 5. VERIFY REFRIGERANT LINE SIZE PER MANUFACTURERS INSTALLATION INSTRUCTIONS PRIOR TO WSTALLATION. 6. GC TO PROVIDE ANY NECESSARY CONDUIT & PENETRATIONS. � ROUND DUCT SUPPORT DETAIL 4 DUCT SUPPORT DETAIL � WALK-W COOLER PIPING DIAGRAM � SUBMARINE DETAIL Scale: N.T.S. Scale: N.T.S. � Scale: N.T.S. � U Scale: N.T.S. FIRE DAMPER STYLE B, ROOM DIFFUSER WITH DAMPER CURTAIN P'PE RE2 SQUARE �OR REGISTER 2'-6° 4" THROAT ELBOW a OUT-0F AIRSTREAM. WITH DOUBLE WALL � CONSTRUCTION AS PER VANES �' f NFPA90A SOLID ROUND 111 ELBOW VERTICAL n 1 � � DUCT �—I �,, � � � � TYPICAL �? 11� ROUND DUCT STANDARD � � / / V � o o " BELLMOUTH � � � � / A / N M � VERTICAL ' ~ o � RETURN DUCT � r � � 45° CLINCH COLLAR EXHAUST � ACCess 000R WITH GASKET WITH PIANO HINGE 6�� 4�_��� AND SASH LOCK ECCENTRIC 5'-0" TRANSITION� f�=30° MAX B PLAN VIEW 18°ENCLOSUREPANEL --------, --------------- ~ � } RouNooucTSR=sw�2 18" ENCLOSURE PANEL r � CLF LIGHT INTEGRAL �ceNTew.iNe sT� Ra�ius� (SHIPPED LOOSE) � I I � � TYPICALMANUAL -f I I RECTANGULAR DUCTS R1 MIN. � (SHIPPED LOOSE) � VOLUMEDAMPER HANGER BRACKET � I I II a�, �z=R� � W I MESH FILTER HANGER BRACKET REFERTOSPECIFICATIONS R FOR PRESSURE AND SEAL R� I I CLASSIFICATIONS � � _� f— � � �_ � � W � � o SUPPLY OR RETURN DUCT �� NOT USED 14 NOT USED V Scale: N.T.S. �� Scale: N.T.S. Scale: N.T.S. � � , 3'-0" �, , g�_p� � ROUND INSUL STUB DUCT SAME SIZE AS FLEX DUCT FRONT VIEW SHOP FABRICATED SHT MTL CLG DIFUSSER CAP NET INSIDE DIM. SAME AS DIFFUSER NECK — OPPOSED BLADE DAMPER TITUS AG-75 OR EQUAL WHEN REQD EQUALIZWG GRID PERPEND TO STUB DUCL FULL SIZE OF DIFFUSER CAP. HEIGHT FROM DIFFUSER NECK TO STUB CNTRLN. FLEX DUCT CLAMP � FABRICATE FROM 22GA PERF SHT MTL (�' -ONE UNIT REQUIRED PER OVEN LOCATION � FLEX DUCT. PULL INSIDE HOLES ON a' CNTRS). 4 NOTE: HOOD AND EXHAUST FANS BY VENDOR; — �LINER TAUT � DUCTS BY G.C. � EXPOSED MATERIAL: � 18 GA TYPE 430 S1S, #3 POLISH � LIGHTS: EQUIPMENT (2) CFL (INTEGRAL-BULBS SUPPLIED) BY VENDOR BY OTHERS FILTERS: NOTES: (1) 20x20 ALUMINUM MESH 1. PROVIDE SUPPORT FOR � � CLG DIFFUSER. FASTEN TO CAP W/ CONTROIS: DIFFUSER & CAP PER CODE SHT MTL SCREWS, MIN ONE PER FAN SPEED CONTROLLER, ON-0FF LIGHTED LIGHT SIDE. SEAL JOINT AIR TIGHT SWITCH 2. EQUALIZING GRID REQ'D ON SWITCHES TO BE LOCATED AT MASTER SWITCH BANK EXHAUST: SUPPLY AIR DIFFUSERS ONLY 300-1000 CFM TYP SUSP LAY-IN CEILING SIDE VIEW 3 TYPE II KITCHEN HOOD 9 LAY-IN CLG DIFFUSER 12 NOT USED 15 NOT USED Scale: N.T.S. Scale: N.T.S. Scale: N.T.S. Scale: N.T.S. �'f � � � �1' 7[+[� E'i� [+l'i4�J 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 �.�..� 1..1� Q U i z M � z J w � U ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 ```'\p4ip� �n nl rn rr ppe, ,r ° o�t" �- S�tii,�� o ��,�Q-,•'��sTf��.. �°, .�'.�� ,,� �`e ' No.153C01�J4 - � ,� STh7� CF� ' Q ' ��T��,�n/GIfNP,"���k,-``„ °'���SS�oNn����,�`°�n , SHEET TITLE MECHANICAL DETAILS SHEET NUMBER M4.Q M � u� 0 � 0 N � w m � � z � w 0 � a 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 VWWJ.POTBELLY.COM � � /��_ GPD GROUP, [NC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 W �(� Li Q U Z � 0 r W H � C/� � Q � � J N � M � O V � Z z � � J � W rn � N � �n Q � U � M � � 0 � 0 N � w m � _ z U w 0 � a ,,,��o�������,,,o„ �,c ''�o�t;�,�' S�tii,�°° . v`�Q'.' G\STFR�, (!`�;. ^ '� ; 'Q-4' C ' No.19300104 - ' � �, �r.� ; � �.a°. SIATEOF <'�: %��,o�� �NDIANP•^•��'�'� �. FS ."--,- ��� . %... S�oNa� E ..o°°°D � ��� SHEET TITLE MECHANICAL ROOF PLAN SHEET NUMBER M5.0 PLUMBING SYMBOLS LEGEND W WATER SERVICE — CW — COLD WATER SUPPLY PIPING — HW — HOT WATER SUPPLY PIPING — � — TEMPERED WATER SUPPLY PIPING �r' SANITARY DRAINAGE & WASTE PIPING/SEWER — — — — SANITARY VENT PIPWG G NATUR4L GAS PIPING —�� LINE SIZE GATE VALVE —�-- LINE SIZE BALL VALVE (2" & SMALLER) —�-- LINE SIZE BALANCWG VALVE —i•'r— LINE SIZE CHECK VALVE �IF— LINE SIZE UNION T� LINE SIZE GAS COCK VALVE AFF ABOVE FINISHED FLOOR GB CAST BRASS CIP CAST IRON PIPE CI CAST IRON CO CLEANOUT CP CHROME PLATED ETR EXISTING TO REMAW FGO FLOOR CLEANOUT FD FLOOR DRAIN GALV GALVANIZED NC NEW CONNECTION S SANITARY V VENT UTR VENTTHRUROOF W WASTE � FS. RECOMMENDED FLOOR SINK LOCATION. VERIFY WITH ARCHITECT. � IND �NDIRECT WASTE DRAIN, HUB DRAIN, PLOOR DRAIN W/ FUNNEL OR SIMILAR. VERIFY WITH ARCHITECT � FD FLUSH FLOOR DRAIN AND GRATE O KITCHEN EQUIPMENT ITEM NUMBER- ADDITIONAL INFORMATIONS CONSTRUCTION AND BIDDING NOTES: 1. THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL PLUMBWG SYSTEM. THE CONTRACTORSHALL FURNISH ALL LABOR, MATERIAL AND EQUIPMENT RELATED TO THE INSTALLATION OP THE PLUMBING WORK 2. THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREP;S WHERE FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE PLUMBING WORK. 3. EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ASME, ASTM, UL, NEMA, ANSI, ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. 4. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO POTBELLY. 5. THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE PLUMBING WORK. 6. THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY POTBELLY AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRINGDEFECTIVE MATERIALS AND WORKMANSHIP. 7. THIS CONTRACTOR SHALL OBTAIN A COPY OF THE WORK LETTER FROM THE PSW CONSTRUCTION MANAGER PRIOR TO SUBMISSION OF THE BID. THIS CONTRACTOR SHALL SUBMIT SAID WORKLETTER AS EVIDENCE OF HAVING REVIEWED CONTRACTORS RESPONSIBILITIES WITHIN SCOPE OF WORK. ANY DISCREPANCIES BETWEEN THE WORKLETTER AND THE DESIGN DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE PSW CONSTRUCTION MANAGER, BEFORE BID DUE DATE PIPING: SOIL, WASTEAND VENT PIPING SOIL, WASTE AND VENT PIPING 10" AND SMALLERSHALL BE SERVICE WEIGHT, HUBLESS, CAST IRON PIPE AND FITTINGS WITH NEOPRENE GASKET AND STAINLESS STEEL SHIELD AND CLAMP. PROVIDE HUB & SPIGOT, SERVICE WEIGHT CAST-IRON SOIL PIPE AND FITfINGS BELOW GRADE WHERE REQUIRED BY LOCAL CODES. SCHEDULE 40 ABS OR PVC PIPE AND FITTINGS WITH SOLVENT WELD MAY BE SUBSTITUTED FOR SOIL, WASTE AND VENT PIPING ABOVE AND BELOW GRADE IF ALLOWED BY LOCAL AUTHORITY. ALL HORIZONTAL RUNS SHALL DRAIN AT A GR4DE a' PER FOOT WHERE POSSIBLE BUT IN NO CASE LESS THAN 'g' PER FOOT. COORDINATE WITH LOCAL AUTHORITIES FOR DRAINAGE REQUIREMENTS FOR EQUIPMENT DESIGNATED WITH INDIRECT WASTE TO FLOOR DRAWS. PROVIDE PIPED DRAIN TO SANITARY IF REQUIRED BY LOCAL JURISDICTION. DOMESTIC WATER PIPING DOMESTIC WATER PIPING 2q' AND SMALLER SHALL BE COPPER TUBE (OR PEX WHERE CODE ALLOWS) WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH NON-LEAD, NON-ANTIMONY SOLDER.PROVIDE TYPE "L" COPPER TUBE ABOVE GRADE AND TYPE "K° BELOW GRADE. CONDENSATE DRAINAGE PIPING THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DR41NS FOR AIR HANDLING UNITS AND POTBELLYS EQUIPMENT (REFER TO SCHEDULE). CONDENSATE DRAINAGE PIPING SHALL BE TYPE "M" COPPER TUBING WITH WROUGHT COPPER SWEP,T FITTINGS JOINED WITH 50/50 SOLDER. NATURAL GAS PIPING GAS PIPING SHALL BE SCHEDULE 40, SEAMLESS, BLACK STEEL PIPE. PROVIDE PIPING SUPPORT BLOCKING ON ROOF, COMPATIBLE WITH ROOFING SYSTEM. HANGERS & SUPPORTS THE PLUMBING CONTRACTOR SHALL FURNISH ALL PIPE SUPPORTS REQUIRED FOR EQUIPMENT AND MATERIAL. ALL HORIZONTAL RUNS OF PIPIN� SHALL BE SUPPORTED BY PIPE HANGERS INSTALLED AS REQUIRED BY LOCAL CODES ADDITIONAL SUPPORTS SHALL BE PROVIDED WHERE REQUIRED TO PREVENT SAGGING. HANGERS AND PIPE ATTACHMENTS TO BE FACTORY FABRICATED WITH GALVANIZED COATINGS; NONMETALLIC COATED FOR HANGERS IN DIRECT CONTACT WITH COPPER TUBING. CONNECTIONS INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO EACH PIECE OF EQUIPMENT. INSTALL DIELECTRIC COUPLINGS TO CONNECT PIPING MATERIALS OF DISSIMILAR METALS. SCREW JOINT STEEL PIPING UP TO AND INCLUDING 1-112". WELD PIPING USE NON-LEAD, NON-ANTIMONY SOLDER FOR SOLDERING DOMESTIC WATER COPPER PIPE. CLEANOUTS PROVIDE J.R. SMITH OR EQUIVALENT FLOOR AND WALL CLEANOUTS AS INDICATED ON THE DRAWINGS OR WHERE REQUIRED BY CODE IN ALL SOIL, WASTE, AND DRAIN LINES. IN AREAS WITH CERAMIC TILE OR CARPETED FLOORING, PROVIDE CLEANOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE TOP. IN AREAS WITH RESILIENT FLOORING, PROVIDE CLEANOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE TOP WITH TILE RECESS. CLEANOUTS SHALL BE SAME SIZE AS PIPE EXCEPT THAT CLEANOUTS LARGER THAN 4" WILL NOT BE REQUIRED. WHERE CLEANOUTS OCCUR IN WALLS OF FINISHED AREAS, THEY SHALL BE CONCEALED BEHIND CHROME PLATED ACCESS COVERS. 8. PROVIDE AND INSTALI AlL °P" TRAPS, MANIFOLDS, DRAIN LINES, SHUT-OFFS, GREASE TR,4PS & BACKFLOW PREVENTORS AS REQUIRED BY EQUIPMENT AND/OR LOCAL CODES. ALLKITCHEN, DINING ROOM AND BAR AREA WASTES ARE TO BE OPEN SITE IN FLOOR, UNLESS OTHERWISE SPEGFIED. 9. IF WATER PRESSURE AT EQUIPMENT AREA EXCEEDS 40 P.S.I. FLOW PRESSURE, INSTALL A PRESSURE REDUCING VALVE ON BOTH THE MAIN HOT AND COLD WATER SUPPLY LINES. 10. LOCATE AND FURNISH ALL AREA FLOOR DR41NS UNLESS OTHERWISE SPECIFIED. 11. PROVIDE AND SIZE ANY SOFTENING AND FILTERING EQUIPMENT THAT MAY BE REQUIRED UNLESS OTHERWISE SPECIFIED. 12. DETERMINE SIZE OF GAS SUPPLY LINE REQUIRED FORALL GAS EQUIPMENT INCLUDING FOOD SERVICE EQUIPMENL 13. PLUMBER TO PROVIDE AND INSTALL BACKFLOW PREVENTORS ON ALL EQUIPMENT AS REQUIRED BY LOCAL CODE 14. 15. THESE PLANS ARE FOR INFORMATION ONLY. INFORMATION ON THIS SHEET IS TO BE REVIEWED BY THE OWNER AND INCORPORATED INTO THE BUILDWGS' MECHANICAL PLANS IN ACCORDANCE WITH LOCAL CODES. THE ENTIRE INSTAILATION SHALL CONPORM WITH THE LATESET EDITION OF THE LOCAL AND STATE PLUMBING CODE IN ADDITION TO LANDLORD REQUIREMENTS AND SPECIFICATIONS. 16. THE OWNER SHOULD SUBMIT THESE PLANS TO LOCAL BUILDING, HEALTH AND FIRE DEPARTMENT OFFICIALS FOR APPROVAL. 17. CONTRACTORS TO MAKE USE OF ANY CONNECTIONS ALREADY INSTALLED IN EXISTING BUILDWG WHENEVER POSSBLE 18. CONTR4CTORS TO PROVIDE AND INSTALL WALL BAGKING FOR WALL SHELVES. WALL MOUNTED HANDSINKS, WALL MOUNTED COOKING EQUIPMENT, ETC. VERIFY THESE LOCATION WITH OWNER. 19. FLOOR DRAINS AND/OR FLOOR SINKS SHOWN ARE RECOMMENDED LOCATIONS. PIPING (CONTINUED): INSTALLATION INSTALL EXPOSED PIPING FREE OF SAGS AND BENDS. PROVIDE BR4CKET STANDOFFS FROM MOUNTING SURFACES SUFFICIENT TO ALLOW 1" CLEANING SPACE AROUND ALL PIPING, INCLUDING ANY ADDED PIPING INSULATION. INSTALL FITINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WALLS, GYPSUM BOARD PARTITIONS, CONCRETE FLOOR AND ROOF SLABS. SEAL PIPE PENETRATIONS THROUGH RATED CONSTRUCTION WITH FIRESFOPPING SEALANT MATERIAL. UNDERGROUND WATER AND SEWER LINES SHALL BE LAID fN SEPARATE TRENCHES WITH A MINIMUM HORIZONTAL SPACING AS REQUIRED BY CODE, EXCAVATED TO THE PROPER DEPTH AND GRADED TO PRODUCE THE REQUIRED FALL. TESTING ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE BACKFILLED OR CONCEALED. AFTER TESTING IS GOMPLETE, THE PLUMBING CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS REQUIRED BY LOCAL AUTHORITY. TEST WATER PURITY ACCORDING TO LOCAL REQUIREMENTS AND SUBMIT CERTIFIED TEST RESULTS TO ENGINEER FOR REVIEW AND APPROVAL. PIPING INSULATION: WATER PIPING PROVIDE THERMAL INSULATION ON ALL HOT TEMPERED & CALD WATER; AND HORIZONTAL WASTE PIPING IN CEILING SPACES, AND ON ALL COLD WATER PIPING IN CASEWORK AND BAR AREAS. USE SELF-SEALWG CLOSED CELL FOAM OR JACKETED FIBERGLASS INSULATION WITH MANUFACTURE APPROVED ADHESIVES, SEALERS, AND COATINGS. ALL MATERIALS USED SHALL NOT EXCEED 25 FOR FLAME SPREAD, 50 FOR FUEL CONTRIBUTED, OR 50 FOR SMOKE DEVELOPED. EVALUATE INSULATION OF WATER LINES, ONLY INSULATE AS REQUIRED BY CODE. UNLESS OTHERWISE REQUIRED BY THE LOCAL AUTHORITY OR ENERGY CODES, THE MINIMUM INSULATION LEVELS SHALL BE AS FOLLOWS PIPE SIZE INSULATION THICKNESS LESS THAN OR EQUAL TO 1�w 1" 2" DIA. OR GREATER 1�" (INSULATION VALUE = k VALUE NOT EXCEEDING 2.027 BTU PER INCHlh*ft *f SAPETY COVERS INSTALL SPECIFIED NO-SCALD SAFETY COVERS WITH INSULATED FOAM LINER AND TAMPER PROOE STRAP AT ALL EXPOSED PIPING. ICE BIN DRAW INSULATE ICE BIN COPPER DRAW LINES WITH �' THICK, SELF-SEALWG, SECTIONAI, CLOSED CELL FOAM. HVAC PIPING INSULATE REFRIGERANT SUCTION PIPING AND COOLING COIL CONDENSATE PIPING �" THICK, SELF SEAIING, CLOSED CELL FOAM. INSULATE HVAC HOT AND WITH CHILLED WATER PIPING SYSTEMS AND LOW PRESSURE STEAM AND CONDENSATE PIPING WITH 1�" THICK, HEAVY DUTY, SELF SEALING, JACKETED FIBERGLASS. PIPING VALVES: GENERAL PLUMBING CONTRACTOR TO PROVIDE VALVES WHERE INDICATED ON PLANS AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE NOTED) BETWEEN VALVE AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO EQUIPMENT FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT MOVING EQUIPMENT. VALVES PROVIDE VALVES FOR WORKING PRESSURE IN WATER PIPING OF 125 PSI OR GREATER. UNLESS NOTED OTHERWISE VALVES SHALL BE AS FOLLOWS: VALVETYPE MANUFACTURER MODELNO. CHECK VALVE (UP TO 2") NIBCO #5-22 FULL PORT BALL VALVE (UP TO 3") NIBCO 4iS-FP-600 GATE VALVE (UP T0 3") NIBCO #5-113 TEMP. AND PRESSURE RELIEF VALVE WILKINS #TP1100A WATERHAMMERARRESTOR WILKINS #1250 BACKFLOW PREVENTER (SWGLE DEVICE) WILKINS #700 VACUUM RELIEF VALVE WILKINS #35VCH PRESSURE REDUCING VALVE WILKINS #500YSBR TR4P SEAL PRIMER JAY R. SMITH #2699-1 SUPPLY IF WATER PRESSURE SUPPLIED TO STORE IS GREATER THAN ANp 65 PSI. THEN PROVIDE A PRESSURE REGULATOR TO MAIN SUPPLY TO MAINTAIN WATER PRESSURE. PROVfDE BACKFLOW PREVENTION ON WATER SERVICE IF REQUIRED BY LOCAL CODES. �l�F#,DNfli1/ 5�H'�7Prn� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 6�654 P: 312.951.0600 F:312.951.0300 VV�NVJ.POTBELLY.COM �� /'.� GPD GROUP, WC. 520 South Main Street, Suite 2531 � Akron, OH 44311 330.572.2100 Fax: 330.572.2102 0 � r W � � � � Q 0N 1..1� J N J M � � � J (, �p ao d' "' W � z � LL � z W U C� LlJ � � 1 � � 1— N � w Z � ¢ � � U a ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 ` ,<,�����SC,,,,,,. "'Q'�� G�S�TF �� ��:. no �asar��oa �!E%�1��- SHEET TITLE PLUMBING LEGEND AND NOTES SHEET NUMBER P1.0 � PLUMBING SUPPLY PLA NORTH � SCALE: 1 /4"=1'-0" KEYNOTES OWATER PIPING - CONNECT NEW 1-1/2" WATER PIPING TO THE LANDLORD PROVIDED 1-1/2" CW STUB. VERIFY EXACT LOCATION IN FIELD. 2O EQUIPMENT WATER CONNECTIONS - PROVIED A RPZ OR BACKFLOW PREVENTION ON ALL DIRECT WATER SUPPLY LINES TO EQUIPMENT. OLAVATORY -1/2" CW AND HW DOWN IN WALL TO LAVATORY, PROVIDE WITH THERMOSTATIC MIXING VALVE, ASSE 1070, LOCATED UNDER THE FIXTURE. O¢ WATER CLOSET -1-1/4° CW DOWN IN WALL TO WATER CLOSET. PROVIDE WATER HAMMER ARRESTOR PRIOR TO FINAL CONNECTION (PDI TYPE "B") ODIPPERWELL -1/2° CWAND NW DOWN W WALL TO DIPPERWELL, PROVIDE WITH THERMOSTATIC MIXING VALVE LOCATED AT THE FIXTURE. OICE MACHINE -1/2" CW DOWN IN WALL TO ICE MACHINE. ]O PREP SINK - t/2" CW & HW DOWN IN WALL TO PREP SINK FAUCET. $O 3-COMPARTRAENT SINK - 3/4" CW AND HW DOWN IN WALL TO 3-COMPARTMENT FAUCET. OSHAKE STATION -1/2" CW & HW DOWN IN WALL TO SHAKE STATION FAUCET. 1 O BAG-N-BOX -1/2" CW DOWN IN WALL TO BAG-N-BOX. PROVIDE W1TH BACKFLOW PREVENTER, WATTS MODEL 98D. 11 CONTRACTOR TO PROVIDE AND INSTALL BALANCE VALVE, SET BALANCE VALVE TO 0.25 GPM. � 2 MOP SINK - 3/4° CW AND HW DOWN IN WALL TO MOP SINK FAUCET 13 WATER HEATER -1-1l4" CW DOWN AND 1-1/4" HW UP FROM WATER HEATER MOUNTED ON WALL. COORDINATE WITH ELECTRICAL CONTR4CTOR. 14 HAND SINK -1/2" CW AND HW DOWN IN WALLTO HAND SINK, PROVIDE WITH THERMOSTATIC MIXING VALVE, ASSE 1070, LOCATED UNDER THE FIXTURE. 15 TEA BREWER -1/2° CW DOWN IN WALL TO TEA BREWER 16 DO NOT ROUTE ANY WATER PIPING OVER ELECTRICAL PANELS � � EXISTING 1-1/2" COLD WATER SERVICE TO REMAIN, CONTRACTOR SHALL FIELD COORDINATE EXACT LOCATION PRIOR TO START OF ANY WORK. VERIFY 1-1/2" WATER SERVICE IS PROTECTED BY AN APPROVED BACKFLOW PREVENTION DEVICE. IF FOUND TO BE DEFICIENT, CONTRACTOR SHALL PROVIDE AND INSTALL AS REQUIRED BY LOCAL AHJ. �$ CONTRACTOR TO CONNECT INTO EXISTING 2" GAS PIPING ON ROOF AND EXTEND 2" GAS PIPING AS SHOWN. VERIFY EXISTING GAS METER IS REGULATED FOR 10" W.C. AND HAS A MINIMUM CAPACITY OF 599 CFH. ANY DISCREPANCIES IN THIS INFORMATION SHOULD IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. GAS PIPING IS SIZED BASED ON 10" W.C. AND 0.3" W.C. PRESSURE DROP PER INTERNATIONAL FUEL GAS CODE. 125' TOTAL DEVELOPED LENGTH. 19 ROUTE 1-1/4° GAS PIPING DOWN THROUGH ROOF AND CONNECT TO WATER HEATER, SEE GAS CONNECTION DETAIL ON SHEET P6.0. SEAL PENETRATION WEATHER TIGHT. 2O ROUTE 1-1/4° GAS PIPING ON ROOF AND CONNECT RTU. SEE GAS CONNECTION DETAIL ON SHEET P6.0. 21 ROUTE 1/2" HOT WATER DOWN ALONG WALL TO STAINLESS STEEL BACKFLOW PREVENTER TO BE MOUNTED BELOW CEILING AND ROUTE TO CHEMICAL DISPENSER. ROUTE DRAIN FROM BACKFLOW PREVENTER AND DISCHARGE INTO NEAREST SINK. GENERAL NOTES A REFER TO SCHEDULES, DETAILS AND RISER DIAGRAMS FOR MORE INFORMATION ON SIZING OF PIPING TO EQUIPMENT. B FIELD VERIFY ALL CONDITIONS PRIOR TO BIDDING AND START OF WORK. F1ELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO 1NSPECT EXISTWG FIELD CONDITIONS. THIS CONTRACT SHALL WCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BYTHEARCHITECT, ENGINEEROROWNERAFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COSL BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INGLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR ONMER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. SANQWfCN SNDP�,� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 NNNN.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fa�c: 330.572.2102 � � � W � � � � Q 1..1_ � N � M � � � J � � � W � o z � � � z W U � W � � 1 � � F N � w z � � � � U a `'��e���`� 1� n `S' L'L !a<o • C' `_,�",�7/R°'oo : ��,4;���\ STF,��o �� op No.19300104 - �� _ ,'� ' �'•� STATE OF ; � ti ; °T', �n✓oi�,NP.�" ��v�, . FS,''•---''� G�` �'� es �dds.,��`�NAL `<�..a�''� 17 I SHEET TITLE PLUMBING SUPPLY & SCHEDULES SHEET NUMBER P2.0 ��' 01 PLUMBING WASTE PLAN NORTH C� SCALE: 1 /4"=1'-0" KEYNOTES: ONEW 3" SANITARY VENT UP TNRU ROOF. O2" WASTE DN AND 1-1(2" VENT UP IN WALL FROM SINK OR LAVATORY. O3" WASTE DN AND 2" VENT UP IN WALL FROM FLOOR DRAIN/SINK. O4" WASTE DN AND 2" VENT UP IN WALL FROM WATER CLOSET. O3" WASTE DN AND 2" VENT UP IN WALL FROM MOP SINK. O2" INDIRECT WASTE WITH 4" GAP FROM 3-COMPARTMENT SINK TO FLOOR SINK. O2" INDIRECT WASTE WITH 4" GAP FROM PREP SINK TO FLOOR SINK. O$ INDIRECT WASTE WITH 4" GAP FROM DIPPERWELL TO FLOOR SWK OINDIRECT WASTE WITN 4° GAP FROM ICE MACHINE AND TEA BREWER TO FLOOR SINK. 'I O ROUTE 4" GREASE WASTE BELOW GRADE AND CONNECT INTO EXISTING 4" GREASE WASTE PIPING. FIELD VERIFY EXACT LOCATION, SIZE, DEPTH OF INVfRT, AND DIRECTION OF FLOW PRIOR TO START OF AY WORK. 11 ROUTE MIN. 1" OR AS SPECIFIED CONDENSATE FROM COOLER AND FREEZER CONDENSERS TO MOP SINK AT A SLOPE NOT LESS THAN 1/8" PER FOOT. CONTRACTOR SHALL PROVIDE HEAT TRACING ON CONDENSATE LINES IN FREEZER, COORDINATE WITH ELECTRICAL CONTR4CTOR. 1 Z EXISTING 4" GREASE WASTE DRAW STUBBED TO SPACE BY LANDLORD TO REMAIN. 13 ROUTE 4" SANITARY WASTE BELOW GRADE AND CANNECT INTO EXISTING 4" SANITARY WASTE PIPING. FIELD VERIFY EXACT LOCATION, SIZE, DEPTH OF INVERT, AND DIRECTION OF FLOW PRIOR TO START OF AY WORK. 14 �ISTING 4" SANITARY WASTE LINE STUBBED TO SPACE BY LANDLORD TO REMAIN. 15 PROVIDE CLEANOUT IN CHANGE OF DIRECTION FOR CONDENSATE DRAIN. 16 �-��2" CONDENSATE DRAIN DOWN ALONG WALL TO FLOOR DRAIN WITH REQUIRED AIR GAP. � 7 ROUTE MINIMUM 1-1/4° CONDENSATE DR41N FROM ROOFTOP UNITS AT A SLOPE NOT LESS THAT 1/8" PER FOOT. PLUMBING GENERAL NOTES: A. REFER TO SCHEDULES, DETAILS P,ND RISER DIAGRAMS FOR MORE INFORMATION ON SIZING OF PIPING TO EQUIPMENT. B. FIELD VERIFY AlL CONDITIONS PRIOR TO BIDDING AND START OF WORK. C. VERIFY LOCAL PLUMBING AND HEALTH DEPT. DRAIN REQUIREMENTS FORTHE 3-COMPARTMENT SINK, PREP SINK, AND SHAKE SINK. D. P.C. TO VERIFY LOCATIONS OF SODA EQUIPMENT WITH VENDOR AND10R OWNER. ADJUST PLUMBING LOCATIONS AS NECESSARY. E: G.C. TO PROVIDE ACCESS FOR SODA LINES IF NECESSARY. COORDINATE WITH VENDOR AND/OR OWNER. F. ALL FLOOR DRAINS TO INCLUDE TRAP PRIMERS FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CANTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTR4CT SNALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR ONMER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTR4CTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKWG KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FORALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNWG CODES, TNE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. � 1 /� f ,,r `�.. . s�i�;u�i�c� $�tQrT� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P: 312,951.0600 F:312.951,0300 NNNN:POTBELLY.COM � � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 0 r W � � � Q �N 1..1_ J N J M � � � J (� � � w � � z� � � z w U (,/) w � c � � � G Fz-- N � w Z � ¢ � � U a ,�,,,���„�.,,;r��o 'a"�0�� -�' S��yGc�` °<, ,�'Q-.- ��sr�,q �,,��e ��e`� c - Ro.1B300104 ; ' � ; �.�..........._.�._. ; � : � `�� S7AYE OF ,' � ,- '°m�.�'cA^.�ND i AN�1 �_���be'ef i SHEET TITLE PLUMBING WASTE PLAN SHEET NUMBER P3.0 PLUMBING SCHEDULE ITEM # DESCRIPTION MANUFACTURER MODEL # Count FINISH FURN. INSTALL VOLTS WATTS AMP PLUG HW. SUPPLY CW. SUPPLY TW. SUPPLY WASTE VENT COMMENTS WATER CLOSET-FLO WISE WITH AUTOMATIC MADERA FLOWISE 3249.001, ELOGATED BOWL; PROVIDE 6067 PROVIDE WITH 5905.100 HEAVY DUTY AMERICAN STANDARD SEAT, FLUSH VALVE tt6065.121.002 PROVIDE JBOX IN WALL WITH LOW VOLTAGE P102 FLUSH AMERICAN STANDARD HARD WIRED SELECTRONIC FLUSH VALVE (P104) 2 WHITE GC GC 1" 4" 2" POWER. 3C16X20 - 2-18X, 20"D X 88"L,10"H REAR SPLASH, LEFT & RT P201 THREE COMPARTMENT SINK ELKAY HAND 18" DRAINBOARDS 1 SS VD GC 3/4" 3/4" (3) 2" INDIRECT WASTE, SEE ITEM #P600 FOR FAUCET STAWLESS STEEL WORKTABLE W/ SMK - PREP P204 TABLE ELKAY SLW�30X84BS 1 SS VD GC 3/4" 3/4" 1-112° PROVIDE FLOOR SINK W/ INDIRECT WASTE CONNECTION. SEE ITEM #P601 FOR FAUCET MOLDED STONE INTEGRAL DR41N MSBID2424 W/ 830AA P205 MOP SINK W7FAUCET FIAT SERVICE FAUCET 1 WHITE GC GC 1/2" 1/2" 3" 2" VACUUM BREAKER P206 PLOOR SINK SIOUX MANUFACTURING 861-23X W/ HALF GRATE 861-52i 4 GC GC 3^ Zu P207 FLOOR CLEAN OUT ZURN Z-1400-ZN-G-VP 5 GC GC 4^ VANDAL PROOF SCREWS, GLAVANIZED BODY, ROUND NICKEL BRONZE TOP P208 FLOOR DRAW SIOUX MANUFACTURING 842-3-P-NQ 4 GC GC g^ p�� PROVIDE DEEP SEAL TRAPS, ADD VEGETABLE OR MINERAL OIL TO TR4P P210 WALL-HUNG LAVATORY AMERICAN STANDARD LUCERNE 0355.012 2 WHITE VD GC 1/2" SEE ITEM #P611 FOR FAUCET. PROVIDE TEMPERING VALVE P211 HAND SWK ELKAY SEHS-17X -17"L X 15"W X 5'D W/ SIDE SPLASHES 2 SS VD GC 112" 1/2" 1-1/2° 1-1/2" SEE ITEM #P603 FOR FAUCET. PROVIDE TEMPERING VALVE. P214 SHAKE STATION (LEFT HAND VERSION) ELKAY CUSTOM BACK BEVERAGE COUNTER 1 VD VD 112" PROVIDE TEMPERING VALVE P401 CNEMICAL DISPENSER CNEMICAL DISPENSER 1629WML/1629WMR 2 VD VD 1/2" CONTAINS ALUMINUM CLORIDE. PROVIDE STAINLESS STEEL DOUBLE CHECK BACKFLOW PREVENTOR P406 TEMPERWG VALVE LEONARD 220 4 GC GC PROVIDE AT EACH HAND SINK AND LAVATORY, SET T0100' F P408 BUILT-IN DIPPERWELL T&S BRASS 006678-45 W/ 82282-F03 1 SS VD VD 1/2" 1 1/2" FAUCET INCLUDED P409 RINSER BLENDTEC JRE-610 LITTLE BLACK RINSER 1 SS VD VD NEMA P410 TEA BREWER BUNN T63Q 1 VD VD 120/1/60 1780 14.8 5-1SP 1/4" &0230-LN FAUCET;�64X 16"SWING NOZZLE W/STREAM P600 3 COMP SINK FAUCET T&S BRASS REGULATOR 1 VD GC 1/2" 1/2" P601 PREP TABLE SINK FAUCET T&S BRASS 8-0225-W FAUCET;135X 12" SWIVEL GOOSENECK 1 VD GC 1/2" 1/2" B-1115-LN FAUCET;131X SWING GOOSENECK; 1136-45 TEFLON P603 HAND SWK FAUCET T&S BR4SS SEAT WASHERS 2 BRONZE VD GC 1/2" 1/2" PROVIDE TEMPERING VALVE 8° WALL MOUNT FAUCET, ADD-ON FAUCET W/8" SWING NOZZLE, CERAMIC CARTRIDGES, COMPACT SPRING & FLEX HOSE, B-0107-C SPRAY P605 SPRAYER NOZZLE T&S BRASS B-0133 W/ 063X, B-0155-LNEZ & B-0970-FEZ 1 CHROME VD GC 1/2" VALVE, VACUUM BREAKER & 6" WALL BRACKET & LEVER HANDLES P610 SHAKE STATION FAUCET & TEMPERING VALVE T&S BRASS B-0306 1 CHROME VD VD 1/2" P611 B LEVER LAVATORY FAUCET-4" SPREAD MOEN 8413SP 2 CHROME VD VD 1/2" t/2" USE FOR NEW STORES P703 WALK-IN COOLER/FREEZER-SIDE DOOR KOLPAK CUSTOM 1 VD GC REFRIGERATION HOOK-UP BY EQUIPMENTVENDOR P704 SODA/ICE DISPENSER CORNELIUS IDC255 1 VD VD 120/60 9.3 3/8" 3/4" P707 ICE MAKERAT SODA MACHWE-AIR-COOLED HOSHIZAKI AMERICA, INC. KML-451MAH 1 SS VD VD 115/60/1 10.3 1/2" 3/4" STANDARD AIR COOLED UNIT COOLER REFRIGERRTION SYSTEM - REMOTE 208-230/60/ ALLOWS CONDENSOR TO BE LOCATED ON THE ROOF OR OUTSIDE TO REDUCE HEAT WSIDE STORE; REFRIGERATION HOOK-UP BY P715 COOLER KOLPAK POLARPAK 1 VD GC 1 EQUIPMENTVENDOR COOLER REFRIGERATION SYSTEM - REMOTE 20&230/60/ ALLOWS CONDENSOR TO BE LOCATED ON THE ROOF OR OUTSIDE TO REDUCE HEAT WSIDE STORE; REFRIGERATION HOOK-UP BY P716 FREEZER KOLPAK POLAR PAK 1 VD GC 1 EQUIPMENT VENDOR P800 GAS WATER HEATER BRADFORD WHITE OR EQUAL EF-60T-199 1 GC GC 120/1 1.8 1° 1" REFER TO INSTALLATION GUIDE FOR MORE INFORMATION, EXPANSION TANK TO BE PROVIDED. P802 INDIRECT WASTE FUNNEL ZURN Z326 1 GC GC 2° TO BE USED AS REQUIRED BY CERTAIN JURISDICTIONS WHERE FLOOR SINKS ARE NOT ALLOWED P805 LEVER TWIST WASTES T&S BRASS B-3950 2 VD GC P807 WATER HEATER STAND NATIONAL HOT WATER PK101 1 GC GC �:. �k r--� • r i � . 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 6�654 P: 312.951.0600 F:312.951.0300 1MNW.POTBELLY.COM � /�i� GPD GROUP, INC. 520 South Main Street, Suite 2531� Akron, OH 44311 330.572.2100 Fax: 330.572.2102 0 Q �N L.1� J N J M � � � W � � � z� LL � z W U � w � � 1 � � F— N � W Z � Q � � U a �eaaonnnsavro � a°° O���J" sC��'�,c'°�, �� - �ST� � .�<✓�•�tiG `RFQ �;D`i. - Na 1930r,104 �9 �, m.._.�_.,.._�e ' �" . ;.,C`, STATEOF .'��o< : O�,`. �NDIANP.'���q` �'°.�S510 N A'� �c�,, °''• �e �pn�� �eU� lJ�lt� SHEET TITLE PLUMBING SCHEDULE SHEET NUMBER P4.0 � c sa�uwrtcn �nvrrM 222 MERCHANDISE MART PLAZP„ SUITE 2300 CHICAGQ IL. 60654 P:312.951.0600 F:312.951.030� NNVW.POTBELLY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 � Akron, OH 44311 330.572.2300 Fa�c: 330.572.2102 � 0 r W H � � � Q O � J N J M � O � J � � � W � � Z �' � � z W U Cn W � � � � � z N � W Z � '� � � U � ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 REVISION 1 02.05.16 ,pealneivrervqer >.°�Ci`1�E'.�- SCIY/c� ;, ��Q','�G1STF��� ���,, Q No.19300104 � �� r.�.��._.�.� ; R� � .o �. STATE OF �`�� �� ',�o,c:•, /NDIANP-° �`<'�i _,. <c„ . � _ � �',��� � SHEET TITLE PLUMBING RISERS SHEET NUMBER P5.0 GREASE INTERCEPTOR SIZWG: BASED UPON FLOW 3-COMP SINK VOLUME = 43.6 GALLONS �+a1 I DRAW LINE PREP SINK VOLUME = 7.3 GALLONS 7--j` SHAKE STATION VOLUME = 2.1 GALLONS RAINCAP CONCENTRIC VENT/COMBUSTION � � MOP SINK VOLUME =18.7 GALLONS AIR THRU ROOF FLOOR GRATE �' FLOOR DRAWS ARE FOR SPILLAGE ONLY AND DO NOT CONTRIBUTE TO CALCULATIONS. FINISHED FLOOR MOUNT 1^ � I (SEE TOTAL CONNECTED VOLUME IN GALLONS = 7L7 ROOF �� �NATERPROOF PENETRATION ABOVE FLOOR AIR GAP= 2 X"d" ARGHITECTURAL THEREFORE OUR REQUIRED TOTAL FLOW-THROUGH RATING IS 75 GPM COORDINATE ROOFWG WORK W! FOR FLOOR BASED UPON TABLE 1003.3.4.1 OF THE IPC, � LANDLORD CONTRACTOR SLOPES) GREASE RETENTION CAPACITY REQUIRED IS 150 LBS. � , SIUCONE BEAD CIRCULATING PUMP EQUAI `� "= PSW REQUIRED A MINIMUM OF 150 LBS CAPACITY CHECKVALVE (TYPICAL) TOATAC0009 LIFT OUT ALUMINUM, . PROPOSED CONNECTED LOAD OF 75 GPM, 150 LBS CAPACITY (GREASE INTERCEPTOR SEDIMENT BUCKET y' FOR SOLE USE OF POTBELLY). ° c °� '^ LANDLORD PROVIDED 1000 GALLON GREASE INTERCEPTOR DHWR �`.� o . . . . . . . �' •J.�' �' . . . . 0 o DHW– ---�0 AQUASTAT � PiPe O � BALANCWG VALVE � SET TO 0.5 GPM. BALL VALVE (TYPICAL) PIPE HANGER WITHIN 3" OF ELBOW DCW AUTOMATIG VACUUM RELIEF = VALVE (WHEN REQUIRED) � PROVIDE ASME TEMPERATURE l ^ PROVIDE PIPE UNION, DIELECTRIC � FLOOR SINK 4 GREASE INTERCEPTOR SIZING AN�PREssuREREUEFva�vE — iFREQuiRE�FOR�issin�i�aR NOT USED Scale:l:1 Scale:1:1 RATED AT 210°fl150 PSIG. , METALS. � 3 Scale:l:Y --- � WELDED STEEL EXPANSION TANK � WITH POLYPROPYLENE LWWG, FDA APPROVED FOR DOMESTIC WATER SERVICE. PRECHARGE TANK TO DRAIN VALVE 3�4�� MATCH WATER PRESSURE AS PER TANK MANUFACTURER. OATEY 34152 22" DIAMETER o -- LOW STRAINER POSITION -- HIGH STRAINER POSTION � ALUMINUM DRAIN PAN WITH 1" — * SEISMIC STRAP, TYP. SEE NOTE. FLR DRAIN SET BELOW TOP OF CAULKJOINT CAST IRON DRAIN FITTING �u FIN FLR. ADJACENT TILE COVER PROVIDE HARD COPPER DRAW CANTS TO CREATE DIMPLE THIN SET CERAMIC FIN. FL00 FLOOR FOR PRVtDRAIN PAN OUTLET. 83/8" TILE, TYP ROUTE DISCHARGE LINES FULL 5" SQ SIZE TO FLOOR COMPLETE WITH MINIMUM 21/2" AIR GAP. `. MOISTURE BARRIER ° � � :>! ADJUSTING COLLAR ;;_, • , , NOTES: � � '►' CLEANOUT PLUG AND RISER 1. ALL PIPING SHALL HAVE A MINIMUM OF 1" OF INSULATION. � BODY. SEE SPECS. 2. PROVIDE A TIME SWITCH OR OTHER CONTROL DEVICE THAT CAN BE SET TO ° .�� 4u. .. ��- . . �`•� 1/8 BEND FULL SWITCH OFF THE USAGE TEMPERATURE MAINTENANCE SYSTEM DURING � . ►,.�. � o ' �. • • • SIZE; 4" MAX. EXTENDED PERIODS WHEN HOT WATER IS NOT REQUIRED. . �. �, � ...�.. •'•. PLUG IF END OF LWE 3�� FLOW — � 2 FLOOR DRAIN 5 FLOOR CLEANOUT � WATER HEATER 14 NOT USED Scale: N.T.S. Scale: N.T.S. V Scale: NTS Scale: N.T.S. TERMINATE AIR INTAKE AT 1" BELOW BOTTOM OF DRAINBOARD ALL PIPWG TO BE COPPER WASH RINSE SANITIZE CAP FLOOR SINK 3 3-COMP. SINK 6 NOT USED 12 NOT USED Seale: N.T.S. Scale: N.T.S. Scale: N.T.S. !�? Sd�D1�Fi;CN SNOP,� 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 �MNW.POTBELLY.CAM � /��_ GPD GROUP, INC. 520 South Main Strcet, Sui[e 2531 Akron, OH 44311 330.572.21� Fax: 330.572.2102 O � w � � Q � � J N J M � O � J (, �p °° W � � Z �' � � z w U � W � � � � � z N � w z � Q � � U a ISSUE DATE ISSUE DATE DD SET 11.20.15 CD SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 REVISION 1 02.05.16 JUumvnrva .o«�� � S� �--o,,, ,� ry , > �� _�___ i,c , F � , �Q' e�'G\ s r RF� �•"A �� No.193n0104 - � �� ��_,.�..� ' � e .o � SiATEOF .` tr q �`��,c� �n/DIANP'.•�,��: \'e. F„''...,_.FA.r�\6 � ., ���`�/Ib � SHEET TITLE PLUMBING DETAILS SHEET NUMBER P6.0 ELECTRICAL SYMBOLS LEGEND OJUNCTION BOX � TELlDATA RECEPTACLE � SWITCH (� �CEPTACLE; 120V,1 PHASE DUPLEX, W� 18°AFF,UON � 3 THREE WAY SWITCH /j� SIMPLEX RECEPTACLE: 120V,1 PHASE, � M MOTION (OCCUPANCI� SENSOR `jJ 18" AFF, UON SWITCH � QUAD RECEPTACLE: 120V;1 PHASE,18" � SWITCHBANK SEE DETAIL ON AFF, UON "' E7.0 - n WALL MOUNTED SPECIAL PURPOSE O_J RECEPTACLE T TNERMOSTAT TS THERMOSTAT SENSOR � GROUNDING ELECTRODE - CONNECTION � ELECTRICAL PANEL N� NIGHTLIGHTING 24 HWDAY � WALL MOUNTED SPEAKER � CEILING MOUNTED RECEPTACLE 120V, t I `J OCEILING MOUNTED SPEAKER WP VVEATHERPR00F GFI GROUND FAULT INTERRUPTER gSECURITY CAMERA 0 fACP PHASE HORN STROBE STROBE PULL STATION REMOTE TEST STATION I�PIN��I�IxNL�I:� SMOKE DETECTOR SPRINKLER WATERFLOW SWITCH SPRINKLER TAMPER SWITCH FIRE ALARM CONTROLPANEL SYSTEM NOTES: 1. CONTRACTOR SHALL PROVIDE BACK BOX, CONDUIT, AND CATEGORY 5e CABLE FOR PROJECT. CABLE SHALL BE RUN IN CONDUIT FOR ITS ENTIRE LENGTH BACK TO MANAGER'S DESK. 2. ALL TERMINATIONS, DEVICES AND OTHER EQUIPMENT SHALL BE PROVIDED AND INSTALLED BY PSW VENDOR AND IS NOT IN CONTRACT. 3. CONTR4CTOR SHALL PROVIDE A MINIMUM OF 10 FEET OF ADDITIONAL CABLE AT EACH END OF LINE. CABLE SHALL BE PULLED IN A NEAT AND WORKMANLIKE MANNER AND SHALL BE FREE OF ANY BENDS, CURLS, OR INSULATION DEFECTS. 4. CONTR4CTOR SHALL RUN TWO (2) CATEGORY 5e CABLES FROM DEMARC AS DEFINED BY LANDLORD TO MANAGERS DESK. IT COMPANY WILL MAKE TERMINATION AT DEMARC TO CONTR4CTOR PROVIDED CABLE. 5. CONTR4CTOR SHALL TEST DSL AND PHONE SERVICE LINES AT THE PHONE BOARD AT MANAGERS DESK FOR TONE AND SERVICE. DSL AND PHONE LINES PROVIDED BY LOCAL UTILITY. TEST SHALL BE CONDUCTED AT THE DIRECTION OF THE CM. 6. PSW TO ORDER PHONE AND DSL SERVICE. 7. CONTRACTOR TO RUN ONE (1) 2" CONDUIT FROM PHONE BOARD TO POS. REFER TO DETAIL 12lE7.� FOR CABLING REQUIREMENT& 8 CONTRACTOR TO RUN ONE (1)1" CONDUIT FROM PHONE BOARD TO BACKLINE PHONE FAX. REFERTO DETAIL 12/E7.0 FOR CABLING REQUIREMENTS 9. SEE POS/DATA/PHONE/VIDEO ONE LINE DIAGRAM SHEET E7.0. 10. SEE LOCATIONS OF POSiPHONE/DATA ON SHEET E4.0 11. IF NOT PROVIDED BY LL AS PART OP WORKLETTER, GC TO PROVIDE �" CONDUIT AND PULL STRING FROM DEMARC (LL PHONE ROOM) TO THE PHONE BOARD. 12. NYC SNOPS ONLY - GC TO PROVIDE �' CONDUIT AND PULL STRING FROM BUILDINGS CABLE COMPANY ROOM TO THE MANAGER'S DESK MUSIC SYSTEM NOTES: t CONTRACTOR TO PROVIDE JUNCTION BOX AND PULL STRING FOR WALL MOUNTED SPEAKER. ALL OTHER WORK BY OTHERS 2. SEE SHEET E4.0 FOR LOCATIONS OF ALL SPEAKERS. 3. MUSIC SYSTEM VENDOR IS PLAYNETWORKS. CONTACT: JEFF ROMAN 425-629-2760 JROMAN@PLAYNETWORK.COM 4. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT, ONLY IF REQUIRED BY CODE, FOR ALL SPEAKER WIRE FROM SPEAKER TO MANAGERS DESK. 5. PROVIDE KILL SWITCH AT THE MUSICIAN AREA TO TURN ON/OFF THE SPEAKERS ONLY. SEE KEYNOTE #10 ON E2.0. NOTE: THERE MAY BE SYMBOLS IN THE LEGEND THAT MAY NOT BE USED. I CONSTRUCTIONAND BIDDING NOTES: L ELECTRICAL CODE EDITION: PER CURRENT LOCAL CODE. 2. ALL CONDUITS SHALL BE RUN STRAIGHT AND TRUE AND PARALLEL TO BUILDING WALLS AND STRUCTURE. SUPPORT ALL CONDUIT PER REQUIREMENTS OF LATEST EDITIONS OF APPLICABLE CODES. 3. ALL CONDUIT ROUTWG SHOWN ON THE PLANS ARE APPROXIMATE. THE ELECTRICAL CONTRACTOR IS TO DETERMINE THE BEST ROUTING IN THE FIELD. 4. THE ELECTRICAL CONTR4CTOR SHALL PROVIDE AND INSTALL ALL SAFETY DISCONNECT S4VITCHES, AND FUSES. PROVIDE THREE SPARE FUSES FOR EACH SIZE SPECIFIED. 5. THE PLANS ARE DIAGRAMMATIC AND ARE NOT TO BE SCALED. THE ELECTRICAL CONTR4CTOR SHALL DETERMINE THE EXACT LOCATIONS IN THE FILED TO CLEAR OBSTRUCTIONS. E.C. TO MAKE ALL FIELD MEASUREMENTS AND SHALL BE RESPONSIBLE FOR THEIR ACCURACY. 6. ALL CIRCUIT BREAKERS USED TO SWITCH LIGHT FIXTURES SHALL BE APPROVED FOR THE PURPOSE AND MARKED "SWD". 7. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR THE PROPER IDENTIFICATION AND LABELING OF ALL CIRCUIT BREAKERS. EACH PANEL WILL BE PROVIDED WITH A TYPEWRITTEN CIRCUIT DIRECTORY. 8. ALL PANELS WILL BE PROVIDED WITH A KEY LOCK AND LATCH. EACH PANEL SHALL HAVE TWO KEYS WITH ALL PANELS KEYED ALIKE. 9. INCOMING SERVICE LOCATION SHALL BE APPROVED BY ARCHITECT BEPORE INSTALLATION. 10. ALL ELECTRICAI MATERIAL USED ON THIS PROJECT MUST$E "UL" LISTED AND LABELED. 11. ELECTRICAL SUB-CONTRACTOR SHALL BE RESPONSIBLE FOR BALANCING THE LOADS ON ALL PANELS. 12. THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM(S) OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:OOPM AND S:OOAM. 13. ALL MANUFACTURERS AND THEIR CATALOG NUMBERSSHAT ARE LISTED ON THE PLANS AND SCHEDULES ARE INTENDED TO BE "OR APPROVED EQUAL°. THE ENGINEER HAS THE fINAL AUTHORITY IN APPROVING SUBSTITUTIONS TO THOSE ITEMS LISTED. SUBSTITUTIONS MUST BE APPROVED IN WRITING. 14. ALL FIXTURES, OUTLETS, SWITCHES, PANELS AND HVAC EQUIPMENT SHALL BE GROUNDED PER NEC. 15. SERVICE EQUIPMENT, R4CEWAYS AND ANY CONDUITS SHALL BE GROUNDED AND BONDED PER REQUIREMENTS OF NEC ARTICLE 250 AND APPLICABLE PARTSAF ARTICLE 250. 16. ELECTRICAL CONTR4CTOR TO PERFORM ALL CUTTING AND PATCHING AS REQUIRED FOR THE INSTALLATION OF THEIR WORK. ALL FIRE STOPPING AND SMOKE STOPPING AT ALL PENETRATIONS SHALL BE EQUAL IN RATWG TO THE CONSTRUCTION BEING PENETR4TED. E.C. SHALL RESTORE ALL AREAS DISTURBED BY CUTTING, PATCHING, AND EXCAVATWG TO ITS ORIGINAL CONDITION. 17. ALL MATERIALS AND WORKMANSHIP PROVIDED BY THE E.C. SHALL BE WARRANTED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE OWNER. ALL DEFECTS SHALL BE CORRECTED AT NO COST TO THE OWNER. 18. EMERGENCY, EXIT, NIGHT LIGHT AND SECURITY LIGHTS TO BE ON A DEDICATED CIRCUIT IN SALES AREA SHOWN ON THE PANEL DR4WING. ELECTRICAL SPECIFICATIONS: 1. CONDUITS INSTALLED OUTDOORS SHALL BE 3/4" MINIMUM RIGID HEAVYWALL. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT SUPPORTS FOR ALL CONDUITS. ALL ELBOWS SHALL BE HEAVYWALL STEEL. 2. THE MINIMUM SIZE OF WIRE SHALL BE #12 AWG, CU. THHN/THWN. WIRES INSTALLED UNDERGROUND OR OUTDOORS SHALL BE THW. ALL HOMERUNS OF 75 FEET AND LONGER SHALL BE SIZED ACCORDINGLY BY THE ELECTRICAL CONTRACTOR FOR VOLTAGE DROP. 3. ALL CONDUITS RUNNING FROM OUTSIDE OF BUILDING INTO BUILDING MUST HAVE APPROVED SEALOFFS. 4. LIGHTING AND RECEPTACLES SHOULD BE INSTALLED AND WIRED PER LOCAL, N:E.C. CODES, AND OSHA REQUIREMENTS. PROVIDE GROUND FAULT INTERRUPTER ON ALL RECEPTACLES AND EQUIPMENT REQUIRED BY CODE. LAMPS, LIGHTING FIXTURE HANGING SUPPORTS, BASES, PADS, RODS, UNISTRUTS, ANGLE CLAMPS AND OTHER ACCESSORIES FOR AlL FIXTURES AND EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR, INCLUDING FIXTURES AND EQUIPMENT REQUIRED BY CODE. 5. MC OR AC CABLE SHALL BE ALLOWED IN LENGTHS UP TO 6' TO HOOK UP A FIXTURE OR 12' IN CONCEALED SPACES UNLESS NOT PERMITTED BY CODE Q.E. CHICAGO REQUIRES BY CODE), 6. ALL EMERGENCY SYSTEM UVIRING SHALL BE IN SEPARATE CONDUIT FROM COMMON RACEWAYS AFTER ALL SWITCHING. 19. ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS PRIOR TO SUBMITTING THEIR BID. NO ADDITIONAL COMPENSATION WILL BE MADE TO HIM DUE TO UNFORESEEN WORK OR THEIR LACK OF KNOVVLEDGE OF EXISTING CONDITIONS. 2Q PROVIDE GROMMETS OR TRIM AT ALL CEILING PENETRATIONS FOR FIXTURES OR SUPPORTS. 21. VERIFY IN FIELD SYSTEM GROUNDING FOR THE TENANT SPACE. 22. IT IS THE INTENT OF THESE DRAWING AND ATTACHED ARCHITECTURAL AND ELECTRICAL SPECIFICATIONS THAT THE ELECTRICAL CONTRACTOR SHALL PROVIDE, DELIVER, AND INSTALL ALL NEW ELECTRICAL SERVICES, EQUIPMENT, LIGHTING FIXTURES, SPECIAL SYSTEMS, CONDUITS, WIRING, MATERIALS, POWER WIRING TO ALL EQUIPMENT SUPPLIED BY OTHERS, TOOLS AND EQUIPMENT NECESSARY FOR A COMPLETE INSTALLATION OF ALL ELECTRICAL SYSTEMS, GUARANTEE AND SERVICE. 23. OSHA RULES, REGULATIONS, AND REQUIREMENTS ARE A PART OF THIS PROJECT. ELECTRICAL CONTRACTOR SHALL FOLLOW THEM ALONG WITH STATE AND LOCAL REQUIREMENTS FOR THE SAFETY OF WORKERS ON THE JOB AND PASSERS-BY. 24. ALL WORK SHALL BE EXECUTED IN STRICT ACCORDANCE WITH FEDERAL, STATE AND LOCAL CODES, ACCEPTED BY THE ARCHITECT AND LEFT IN PERFECT OPER4TING CONDITION. 25. PROVIDE ALL NECESSARY LIABILITY INSURANCE POLICIES AS REQUIRED BY THE ARCHITECTURAL SPECIFICATIONS. THIS CONTRACTOR SHALL KEEP THE ARCHITECT, ENGWEER, THEIR CONSULTANTS AND THE OWNER OF THE PROJECT HARMLESS FROM ALL CLAIMS, LOSSES, EXPENSES, OF ANY KIND, INCLUDING BUT NOT LIMITED TO ATTORNEY'S EXPENSES AND FEES, WHERE CLAIMS ARE FILED BY THEIR OWN EMPLOYEES OR ANY SUBSUB-CONTRACTOR HIRED BY THIS CONTRACTOR AND OR THEIR EMPLOYEES. THIS INDEMNITY SHALL ALSO APPLY TO ANY CLAIMS FILED BY OTHERS BECAUSE OF WORK DONE BY THIS CONTRACTOR. 26. THIS ARCHITECTlENGINEER HAS NO DUTY TO CANTROL THE SAFEST METHODS OR MEANS OF THE WORK, JOB SITE RESPONSIBILITIES, SUPERVISION, OR TO SUPERVISE SAFETY AND DOES NOT VOLUNTARILY ASSUME ANY SUCH DUTY OR RESPONSIBILITY. 27. THIS CONTRACTOR SHALL BE RESPONSIBLE TO INSTALL ALL ITEMS SPECIFIED USING CONSTRUCTION METHODS THAT WILL PROTECT PROPERTY AT ALL TIMES AND PREVENT BODILY INJURY AND/OR DEATH. SPECIAL ATTENTION AND PRECAUTION SHALL BE PAID BY THE CONTRACTOR IN SELECTING THE SAFEST METHODS OR MEANS FOR THE INSTALLATION. 28. OMISSIONS FROM THE ARCHITECTS DRAWINGS OF ANY ITEM NECESSARY FOR THE PROPER COMPLETION OR OPERATION OF THE WORK OR AS REQUIRED BY TNE CODE SHALL NOT RELIEVE THE CONTRACTOR FROM FURNISHING THE SAME WITHOUT ANY ADDITIONAL COST TO THE OWNER. WHERE TWO DIFFERENT WIRE OR EQUIPMENT SIZES ARE SPECIFIED ON DRAWING, THE LAR�ER SIZE SHALL BE USED, EXCEPT FOR OVERCURRENT PROTECTION DEVICES NMICH SHAIL MATCH WIRE SIZE AMPERAGE. 29. OBTAIN AND PAY ALL FEES AND PERMITS TO ALL PRIVATE AND PUBLIC AGENCIES HAVING JURISDICTION OVER THE PROJECT, PRIOR TO ORDERING, MANUFACTURING, PURCHASING, OR INSTALLING ANY EQUIPMENT, FIXTURE, OR SYSTEM. CONTACT POWER COMPANY UPON BEING AWARDED THE CONTRACT AND MAKE ALL NECESSARY ARRANGEMENTS FOR POWER. 30. CONSULT AND CHECK AT ALL TIMES THE LATEST ARCHITECTURAL, MECHANICAL, PLUMBING, AND EQUIPMENT ORAWIN�S, WHICH ARE A PART OF THIS PROJECT, FOR EXACT LOCATION OF EACH ELECTRICAL CONNECTION. INSTALL AND 4VIRE ALL EQUIPMENT, SYSTEMS, DEVICES AND FIXTURES AS RECOMMENDED BY EACH MANUFACTURER. 31. ALL EXCAVATING, BACKFILLING, AND RESTORATION OF ALL DISTURBED SURFACES TO THEIR ORIGINAL CONDITION FOR THE ENTIRE ELECTRICAL INSTALLATION SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. SECURITY SYSTEM NOTES: 1. CONTRACTOR TO PROVIDE POWER AT TELEPHONE BOARD FOR SECURITY PANEL. CONTRACTOR TO SPECIFICALLY ENFORCE THE PROPER PLACEMENT OF THE SECURITY EQUIPMENT ON THE TELEPHONE BOARD. 2. CONTRACTOR TO PROVIDE CONDUIT AND PULL STRING FOR CAMERA(S) AS REQUIRED. 3. ALL SECURITY EQUIPMENT PROVIDED AND INSTALIED BY OTHERS. MECHANICAL NOTES: 1. CONTRACTOR TO PROVIDE BACK BOXES AS REQUIRED FOR SENSORS AND THERMOSTATS, CONDUIT TO ACCESSIBLE CEILING, AND PULLSTRING. WIRING AND CONNECTION BY MECHANICAL CONTRACTOR. 32. SERVICE ENTRANCE EQUIPMENT, PROTECTIVE DEVICES AND ACCESSORIES SHALL HAVE A SHORT CIRCUIT CURRENT R4TING GREATER THAN THE AVAILABLE SHORT CIRCUIT CURRENT AT THE LINE SIDE OF THE SERVICE ENTRANCE EQUIPMENT. FOR ENERGIZATION OF EACH ELECTRICAL SERVICE, FOLLOWALL PROCEDURES AS DESCRIBED IN THE LATEST#"PB" PUBLICATION. ENTIRE OPERATION SHALL BE PERFORMED BY QUALIFIED COMMISSIONED PERSONNEL ONLY. 33. ELECTRICAL CONTRACTOR SHALL PROVIDE AN UNDERGROUND EMPTY CONDUIT FROM THE TELEPHONE POLE OR VAULT INTO THE BUILDING AT A DESIGNATED LOCATION. CONDUIT SHALL BE INSTALLED AS REQUIRED BY THE TELEPHONE COMPANY, WITH JUNCTION BOXES AND ACCESS VAULTS, SEE DRAWINGS FOR SIZE. 34. ELECTRICAL CONTRACTOR SHALL PROVIDE ALTERNATE UNIT PRICES, FOR COMPLETE INSTALLATION (FURNISHING, INSTALLING AND WIRING) OF THE FOLLOWING ADDITIONAL DEVICES: 1. EXIT SIGN 2. EMERGENCY BATTERY LIGHT 3.120V TOGGLE SWITCH 4. FIRE ALARM AUDIONISUAL HORN 5. FIRE ALARM PULL STATION 6. JUNCTION BOX WITH 3/4" CONDUIT UP TO CEILING 35. CHECK AND VERIFY ALL VOLTAGES AND SAFETY DEVICES OF ALL EQUIPMENT AND LIGHTING FIXTURES PRIOR TO FINAL INSTALLATION OR WIRING. SWITCHES, STARTERS, PANELS AND OTHER EQUIPMENT SHALL BE INSTALLED TRUE TO PLAN AND LEVEL IN SAME LOCATION AS A GROUP 36. ALL WIRING FOR HIGH AND LOW VOLTAGES SHALL BE INSTALLED IN CONDUIT AS REQUIRED BY ALL CADES FOR ALL SYSTEMS. FOR TEMPER4TURE CONTROL CONDUITS SEE THE MECHANICAL DRAWINGS FOR EXACT LOCATION OF EACH THERMOSTAT. PROVIDE 120V POWER FOR TEMPERATURE. CONTROLANDTELEPHONESYSTEMS. 37. THE CONTRACTOR SHALL OBTAIN A COPY OF THE WORK LETTER FROM THE PSW CONSTRUCTION MANAGER PRIOR TO SUBMISSION OF THE BID. THIS CONTRACTOR SHALL SUBMIT SAID WORK LETTER AS EVIDENCE Of HAVING REVIEWED CONTR4CTORS RESPONSIBILITIES WITHIN SCOPE OF WORK. ANY DISCREPANCIES BETWEEN THE WORK LETTER AND THE DESIGN DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE PSW CONSTRUCTION MANAGER, BEFORE BID DUE DATE. 38. THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. 39. THE ELECTRICAL CONTRACTOR SHALI COORDINATE ELECTRICAL WORK WITH OTHER TR4DES. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT SCALE DISTANCES OFF THE ELECTRICAL DR4WINGS; USE ACTUAL BUILDING DIMENSIONS. 40. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE-ENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING LOCATED WITNIN THE DEMOLITION AREA THAT WILL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED. ��� �������� ����r� 222 MERCHANDISE MART PLAZA, SUITE 230� CHICAGQ IL. 60654 P:312.951.0600 F:312.951.0300 NM+W.POTBELLY.COM � /��_ GPD GROUP, INC. 520 Sou[h Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Pax:330.572.2102 � � � r � � � � Q ��/ 1..1_ J N J M � O � J � � °° w � o z � � � z W Q (� -� � U w � 1 � � Z N � w Z � � � � U a ISSUE DATE ISSUE DATE DD SET 11.20.15 CQ SET 12.14.15 LL REVIEW SET 12.22.15 PERMIT SET 01.07.16 Ci SHEET TITLE ELECTRICAL LEGEND AND NOTES SHEET NUMBER E1.0 � Wl1�ACAI�Q T( Rt HALLWA WALK-IN COOLER/ FREEZER FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONiRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CANTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF iHE DESIGN AND INC W DE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CIARIFICATIONS MADE BY THE ARCHIiECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS WST. BIDDING CONTRACTORS SHALL HAVE A WORKMG KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK WSTALLED IN STRICTACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. iHE CONTRACTOR SHALL ALERT ARCHIiECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. NO. E703 E103A E105 E106A E1066 E106C E107A E1076 E128 E130 E131 E302 E302A E304A E304B E401 E404 E406 E406A E408 E409A E427A E427B M709 P102 P410 P703 P704 P707 P715 P716A P716B P800 S2t6A DESCRIPTION COOLER LIGHTS AND SWITCH DOOR HEATER ELECTRICAL SCHEDULE VAC/PH LOAD 720/1 1.6 A 120/1 7.47 A LINE) 120/1 8.6 A REFRIGERATED DRESS STATIONS (FRONT LINE) 720/1 4.9 A EA. REFRIGERATED DRESS STATIONS (FRONT LINE) i20N 4.9 A EA. � REFRIGERATED DRESS STATIONS (BACK) 120H 4.9 A EA. REFRIGERATE SALAD STATION (FRONT LIN� 120/1 � 5.5 A EA. � REFRIGERATE SALAD STATION (BACK) � 120/1 5.5 A EA. ICE CREAM DIPPWG CA8INET 120/1 8 A. UNDER COUNTER REPRIGER4TOR (SHAKE STATION) 120/1 6.1 A FUTURE EQUIPMENT � 120/1 7 A MEATBALLWARMER 120/1 13.3� A SOUP WARMER 120/1 13.3 A CONVEYOR OVEN 20813 40 A CONVEYOR OVEN 208/3 40 A SLICER 120/7 7 A � PAXMACHWE � 120/1 � 4 A P.O.SEQUIPMENT 120/1 2 AEA. FUTURE EQUIPMENT CARBONATORS BLENDER BLENDER FUTURE EQUIPMENT AUTOMATIC FLUSH VALVE � TEABREWER WALK-IN LIGHTS SODAIICE DISPENSERS ICE MAKER REMOTECOOLER CONDENSOR REMOTEFREEZER CONDENSOR REMOTEFREEZER BLOWER "YA GOTTA GET IT HOT" SIGN 120/1 . 2 A EA. 720/1 5 A 120/1 4 A 120/1 15 A EA. � 120/1 15 A EA. 120/1 15 A EA. 120/1 X A 120/1 14 A � 120/1 3.1 A EA. 12p/1 9.3 A 120/1 19.9 A 208/230/1 12.2 A 208@30/1 9] A 208@30/1 5.7 A 120/1 1.8 A . 120/1 10 A � . �ACAPQ � r111C1 IIAI/'� ............. �......� HAFF 78 in. 72 in. 18 ia 78 in. 18 in. 44 in. 18 in. 44 in. 44 in: 18 in. 44 in. 18 in. 18 in. SEE DETAIL 7/E7.0 SEE DETAIL 7/E7.0 45 in. 44 in. JBOX @ 23" CL IN DIEWALL 44 74 in. 18 in. 18 in. 18 in. 45 in. REFER TO CUT SHEET 18 in. 78 in. 18 in. 24 in. ON ROOF ON ROOF 100 in. 96 in. 24HR. X X X X X X X X X X X � POWER PLAN X x X X X X REMARKS A,J,K A,K D,H D,H D,H D,H D,H D,H D, H D,H D,H D,H D,H A,T,S,R A,T,S,R D,H D,E,H E,F,H,T E,F,H,T D,H D,E,H D,H D,H D qE D,H A,K,M,P D,E,H qD,E,H C C C C E,H ENTRY VEST. — , i i i -- -� qRCUIT(S) RPb RPb RP-15 RP-10 RP-30 RP-12 RP-9 RP-17 RP-19 LP-11 RP-7 RP-14 RP-16 RP-38,40,42 RP-37,39,41 LP33 LP-18 RP-20 RP-8 LP-16 LP-27 LP-35 LP37 LP39,41 LP-23 LP-29 RP-21 RP-26 RP-28 RP-29,31 RP-33,35 RP33,35 LP-25 LP-6 NORTH � SCALE: 1 /4"=1'-0" KEYNOTES: OELECTRICAL EQUIPMENT: SEE RISER DIAGRAM AND SCHEDULES, SHEETS E6.0 & E7.0. 2 HVAC EQUIPMENT: SEE ELECTRICAL CONNECTION SCHEDULE, SHEET E6.0. O3 WATER HEATER PROVIDE DISCONNECT SWITCH AND FEEDER ADJACENT TO WATER HEATER. SEE ELECTRICAL CONNECTION SCNEDULE, SHEET E6.0. OHVAC MAINTANCE RECEPTACLE: E.C. SHALL PROVIDE W.P. GFCI RECEPTACLE INTEGRAL WITH ROOFTOP UNIT IF NOT EXISTING, E.G SHALL CONNECT TO CIRCUIT AS SHOWN. ONOT USED 6 MANAGER'S DESK: SEE DETAIL 3/E7.0 FORALL OUTLET AND CIRCUITWG REQUIREMENTS. OFLY LIGHT. E.C. SHALL PROVIDE OUTLET AT 9'-0" AFF FOR THE FLY LIGHT. ODUCTSMOKEDETECTOR: WIRE TO CIRCUIT RP-3. OFUTURE IT EQUIPMENL INSTALL DUPLEX AT MILLWORK WALL AT 18" AFF. � O MUSICIAN'S AREA: QUAD & KILL SWITCH TIED TO MUSIC SYSTEM AT MANAGER'S DESK. KILL SWITCH TO TURN ON/OFF SPEAKERS ONLY. MOUNT AT 3'-0" TO CENTER OF BOX. PROVIDE FLOOR BOX FOR ELECTRICAL. SEE SHEET A1.0 FOR TRENCHING DETAIL. 11 AUTOMATIC PLUMBING FIXTURES: PROVIDE J-BOX / GFCI OUTLET FOR POWER AT LAVATORY FAUCET AND TOILET FLUSH VALVE. �2 NOTUSED. OVEN OUTLET: 13 GC TO PROVIDE LEVITON 8450 RECEPTACLE AT OVEN OUTLET (1 PER OVEN). CORD & PLUG TO BE SUPPLIED BY VENDOR. E.C. SHALL WIRE RECEPTACLE WITH (3) #4, (1) #8 GND., IN 1-1/4" CONDUIT. 14 HOOD EXHAUSTFAN: INTERCONNECT WITH HOOD CONTROL (KH-1) AND PROVIDE ALL CONDUIT, WIRE, STARTERS REQUIRED FOR COMPLETE INSTALLATION. FAN PROVIDED WITH NON FUSED DISCONNECT SWITCH. CONNECT TO CIRCUITS'LP'-26,28,30 GENERAL NOTES: A. FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. B. ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. C. REFER TO DETAIL SHEETS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. D. THE ELECTRICAL CONTR4CTOR IS RESPONSIBLE FOR CONFIRMING ALL VOLTAGE REQUIREMENTS ON ALL EQUIPMENT. E. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH PLUMBING AND HVAC CONTRACTORS FOR ANY ADDITIONAL EQUIPMENT NEEDING POWER. F. ALL FUTURE EQUIPMENT NEEDED HEREIN SNALL BE PROVIDED WITH AN APPROPRIATE RECEPTACLE AND FULLY WIRED, EVEN IF NOT SPECIFICALLY INDICATED. GFCI BREAKERS (NOT RECEPTACLES) SHALL BE UTILIZED FOR ALL G. 125V,15A AND 20A CIRCUITS TO KITCHEN EQUIPMENT AND FLOOR BOXES. PROVIDE DEDICATED NEUTRAL WIRE FOR ALL OF THESE CIRCUITS. H. ELECTRICAL CONTRACTOR TO VERIFY LOCATIONS OF SODA EQUIPMENT WITH OWNER AND/OR SODA VENDOR.ADJUST ELECTRICALLOC.AS NECESSARY. ELECTRICAL SCHEDULE REMARKS: A. WIRE TO JUNCTION BOX ON EQUIPMENL B. ATTACH RECEPTACLE OR J.B. TO COUNTER OR EQUIPMENL C. WIRE TO EQUIPMENT. PROVIDE DISCONNECT OR CORD AND PLUG AS REQUIRED BY LOCAL CODE. D. PROVIDE RECEPTACLE FLUSH IN WALL. E. EQUIPMENT NOT SUPPLIED BY K.E.C., VERIFY REQUIREMENTS WITH SUPPLIER. F. DEDICATED CIRCUITASOLATED GROUND, PROVIDE ELECTRICAlOUTLET. PROVIDE CONDUIT ACCESS FOR COMMUNICATION CABLE, G. VERIFY WITH OWNER. PROVIDE AND INSTALL CORD & PLUG AND RECEPTACLE. H. EQUIPMENT SUPPLIED WITH CORD & PLUG. I. WIRE FROM CONTROL PANEL TO FAN(S) ON EXTERIOR ROOF. PROVIDE AND INSTALL DISCONNECT & SWITCH. LOCATE SWITCH PER PLAN. J. WIRE FROM SWITCN IN WALK-IN PANEL TO LIGHTS IN GLASS DOOR. K. CONNECTION INSIDE WALK-IN, FROM CEILING. L. FROM FLOOR. M. FROM CEILING. N. WIRE FROM J.BOX TO EQUIPMENT. INSTALL REMOTE CONTROLS SUPPLIED WITH EQUIPMENT. 0. PROVIDE AND INSTALL WALL SWITCH TO OPERATE REMOTE COMPRESSOR. P. INSTALL EXTRA LIGHT SHIPPED LOOSE WITH EQUIPMENT. WIRE TO SWITCH ON WALK-IN, RUN CONDUIT ABOVE WALK-IN. CAULK ALL PENETRATIONS AROUND CONDUIT INSIDE AND OUTSIDE OF WALK-IN. Q. COORDINATE EXACT LOCATION OF OUTLET WITH MILLWORK. OUTLET TO BE LOCATED BEHIND WALL CABINET DOOR. R. E.C. TO USE #6 WIRE AND 50 AMP CIRCUIT BREAKER. S. 50 AMP CORD, PLUG, PIN, AND SLEEVE RECEPTACLE WITH BACK BOX PROVIDED BY K.E.C., INSTALLED BY E.C. T. SURFACE MOUNT RECEPTACLE IN BOTTOM OF CABINET U. FOUR WIRE CONNECTION. UNIT PROVIDED WITH CORD AND PLUG, INSTALLED BY E.C. V. WIRE DEFROST TIMER TO BLOWER COIL. PROVIDED BY K.E.C., INSTALLED BY E.C. W. STUB OUT MILLWORK WALL AND INSTALL OUTLET IN RECESS ON LEFT SIDE OF ICE CREAM UNIT. X. WIRE DEFROST TIMER TO BLOWER COIL. PROVIDED 6Y K.E.C. INSTALLED BY E.C. �J R Pi��:.Y� 1AI�.1 �� if 3�LI��.�Y 1' �ta 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL 60654 P: 312.951.0600 F:312.951.0300 WtMN.POTBELLY.COM ��� /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 SHEET TITLE POWER PLAN SHEET NUMBER E2.0 WOMEN'S TOILET ROOM HALLWAY WALK-IN - COOLER/ FREEZER LP-10 ( 2 7 01 LIGHTING PLAN MEN'S TOILET ROOM � � � i S� � � LP-1 L2�2 h104 P-13 L202 L104 � LP-13 LP-13 L504 L500 L502 8 2 LP-10 LP-13 NO 6 LP-1h lP-1h L310 L310 L310 L502 _ 2 LP-10 LP-1g LP-1g -�II`O S NL � 6 1X5 �AN -� t LP-1g LP-10 2 QUEUING AREA 2 S203 � i I I ( 5 � 15 LP-9i L109 L � � P-10 _. __ r-----� II �P II 6 II� 4 �II L 11 �L-10 __L===== SERVICE LINE r= = =� (�� 4 �p ��l �� �� L ^---� LP-00 n LP-9a L100 MUSICIAN AREA ---� WP 1 LP-9a 0 L401 L102 LP- i 6 O LP-10 NL L109 DINING ROOM � _ S100_ L400 L614 LP-17c n � LP-7d 522� �� L615 L208 L617 II L207 � � L617 LP-7d `� � . l � s L109 LP-9a L100 LP-9a LP-10 2 L204 LP-9a � LP-10 2 L502 L1�3� LP-70 LP-9a nI '� �J � � RP-32 �� I I S100 � � � II � � r� u � i� KEYNOTES OREFRIGERATION EQUIPMENT E.C. SHALL PROVIDE MATERIALS AND FINAL CONNECTION PER MANUFACTURERS SPECIFICATIONS. THE WALK-IN COOLER LIGHT FIXTURE, DISPLAY LIGHTS, DOOR HEATER, PILOT LIGHT SWITCH, AND DISPLAY LIGHT SWITCH IS PROVIDED WITH THE BOX. E.C. SHALL PROVIDE SEAL-OFFS FOR THE CONDUIT PENETRATIONS AND ALL WIRING AS REQUIRED. OEMERGENCY/EXIT LIGHTING E.C. SHALL WIRE EMERGENCY/EXIT LIGHTING TO CIRCUIT INDICATED. E.C. SHALL PROVIDE 1400 LUMEN OR FULL OUTPUT, RATED FOR 90 MINUTE EMERGENCY BATTERY BACK-UP FOR ALL EMERGENCY FIXTURES. REFER TO LIGHTING FIXTURE SCHEDULE ON SHEET E5.0 FOR ADDITIONAL INFORMATION. OEXTERIOR SIGN LIGHTING AT ROOF PARAPET E.C. SHALL PROVIDE J-BOX, DISCONNECT, AND FINAL CONNECTIONS FOR THE SIGN. THE SIGN IS SUPPLIED BY OTHERS. FIELD VERIFY THE EXACT LOCATION AND REQUIREMENTS. VERIFY LOCATION W/ PSW PRIORTO INSTALL. SIGNAGE PERMIT BY OTHERS. OHOOD LIGHTING E.C. SHALL PROVIDE FINAL CONNECTION TO (2) 1-100W INCANDESCENT HOOD LIGHTS TO CIRCUIT LP-12. LIGHTS FURNISHED BY HOOD MANUFACTURER. SEE MECH. OCOOLER LIGHTS STRIPLIGHTS FURNISHED BY COOLER VENDOR, INSTALLED AND AND WIRED BY E.C. ONIGHTLIGHTING LIGHTS IDENTIFIED WITH "NL" TO BE ON UNSWITCHED LEG OF CIRCUIT. OMASTER LIGNTING SWITCHBANK (ON SHEET E7.0) LOW VOLTAGE'MANUAL OVERRIDE' LIGHTING SWITCHES AS MANUFACTURED BY 'WATTSTOPPER #HDLS_SS7 FOR LIGHTING CIRCUITS. E.C. SHALL FIEID VERIFY EXACT MOUNTING LOCATION WITH OWNER PRIOR TO ROUGH-IN OMOTION OCCUPANCY SENSOR SWITCH LIGHT SWITCH WITH OCCUPANCY SENSOR SWITCH. OCURRENT LIMITING DEVICE E.C. SHALL PROVIDE 120V, SINGLE POLE CURRENT LIMITING DEVICE WITH CIRCUIT BREAKER RATED AS INDICATED ON PLANS FOR EACH TRACK SECTION. E.0 SHALL COORDINATE EXACT LOCATION AND REQUIREMENTS PRIOR TO BID. SWITCHWG REQUIREMENTS 35J �� SWITCH LEG (SEE SWITCHBANK E7.0) � CIRCUIT# 35 � CIRCUIT #ONLY (UNSWITCHED LEG OF CIRCUIT) ENTRY GENERAL NOTES VEST. A COORDINATE THE EXACT LOCATION AND MOUNTING HEIGHTS FOR ALL THE LIGHT FIXTURES WITH THE REFLECTED CEILING PLAN WITHIN THE ARCHITECTUR4L SET B LIGHT FIXTURES ARE FURNISHED BY THE OWNER, INSTALLED BY THE GENERAL CONTRACTOR, AND WIRED BY THE ELECTRICAL CONTRACTOR, U.N.O. REFER TO LIGHTWG SCHEDULE SHEET E5.0. C ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. D REFER TO ARCHITECTURAL CASEWORK DETAILS FOR EXACT LOCATIONS OF LIGHT FIXTURES LOCATED IN CASEWORK. E ALL OUTLETS/SWITCHES IN THE PREP ROOM, SERVICE LINE AND TOILET ROOMS SHALL BE WHITE WITH WHITE COVERPLATES AND BROWN WITH BROWN COVERPLATES ELSEWHERE. THIS IS TO INCLUDE ALL SOUND SYSTEM AND PHONE/ FAX COVERS. F SEE SHEET E5.0 FOR COMPLETE LIGHTING SCHEDULE G ALL LIGHTING FIXTURES ON THIS SHEET SHALL BE CIRCUITED TO PANEL "LP". UNLESS OTHERWISE NOTED. H SEE TYPICAL MOUNTING DETAIL. SHEET A5.2 I GC TO PROVIDE RELAYS AT TRACK LIGHTING TO SWITCH CIRCUITS TOGETHER BY AREA CALLED OUT. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDIN� FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. NOR7H BIDDWG CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND � ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE C0.STS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDWG. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGWEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 1/4" = 1'-0' .5 A,119 D'1Rf' I:G N 5 H' Q P rm 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL 60654 P: 312.951.0600 F:312.951.0300 WWJV.POTBELLY.COM �� /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 � � � W � C� 0 � � J N M � O � J (� �p `� W � o Z � � z � � N � Q �- J m U � w = � � � � N � w z � � � r- V a e� �m ` '�� +� �` "�gaa�o �� ,� a� ,����", ud 3 �: � .� ` . ''± e I� SHEET TITLE LIGHTiNG PLAN SHEET NUMBER E3.0 � W/'1�ACAPQ T( Rt ■_ 1. WALK-IN COOLERI FREEZER HVAC 24VAC LINE 11ACAI�C �----------------------------� ir----� �---� i � � � � iI I I � HVAC 24VAC LINE i I I S/D RELAY I I US RELAY ' I � L---J L----� � iAHU & MUA (TYPICAL} i L— — — — — — — — — — — — — — — — — — — — — — — — — — — — J DUCT SMOKE DETECTOR AND LIFE SAFETY RELAY RTU SHUT DOWN CIRCUIT, TYPICAL FOR EACH AHU AND MUA. /'11 ICI IIAIn ..� �..�..� . . � � � � o z FU- W V O � � � o o � � � "' w � z Y a a O � � � LL � � � w a � � � a � ¢ o � a � a � � O O O u" O p Z 00000� w ¢ ¢ ¢ a ¢ m > > > > > > U U U U U � a a ¢ a ¢ � SEQUENCE OF OPERATIONS I�[�]I�'� CENTRAL STATION ALARM SERVICE TO RECEIVE SEPARATE & DISTINCT SIGNALS AS FOLLOWS : A) FIRE ALARM B) SYSTEM SUPERVISORY SIGNAL C) SYSTEM TROUBLE SIGNAL ACTIVATES HORN/STROBES THROUGHOUT FACILITY ACTIVATES AHU & MUA SHUTDOWN TRANSMIT ALARM SIGNAL TO CENTRAL STATION TRANSMIT SUPERVISORY SIGNAL TO CENTRAL STATION TRANSMIT TROUBLE SIGNAL TO CENTR4L STATION � � ��� ��� � � �..,� ROOM LINE 01 SYSTEMS PLAN _ °. ENTRY VEST. _� i i i i —J NORTH C� SCALE: 1/4"=1'-0" KEYNOTES � SENSOR/THERMOSTAT CONTR4CTOR TO PROVIDE BACKBOX, CONDUIT (IF REQ'D) AND WIRE TO CEILING AREA TO SUPPORT NEW THERMOSTAT OR SENSOR BY MECHANICAL CONTR4CTOR. CONFIRM LOCATIONS WITH POTBELLY CONSTRUCTION MANAGER. OSPEAKERLOCATION SPEAKER LOCATIONS SHOWN FOR REFERENCE. LOCATE ABOVE WOOD TRIM. SEE NOTES ON SHEET E1.0 FOR SCOPE OF WORK. OMANAGER'S DESK SEE DETAIL 3/E7.0 FOR ALL OUTLET AND CIRCUITING REQUIREMENTS. OPOS EXTEND (1) CATSe CABLE PER POS, PLUS (1) FOR FUTURE TO JBOXES AS PER DETAIL 12/E7.0. OPHONE/FAXABOVECOUNTER EXTEND (2) CATSe CABLES FROM MANAGERS DESK TO PATCH PANEL BOX @ 44" AFF. ONOT USED OWIRELESS ACCESS POINT EXTEND (2) CATSe CABLES FROM WIRELESS ACCESS POINT JUNCTION BOX LOCATED AT HEIGHT ABOVE HIGH TRIM TO MANAGER'S DESK. VERIFY EXACT LOCATION WITH POTBELLY REP PRIOR TO INSTALLATION. ONOT USED ONOT USED � O FUTURE IT EQUIPMENT PROVIDE SINGLE CAT5e CABLE RUN BETWEEN THE JBOX AT LOAD STATION AND MANAGER'S DESK. LOCATE AT 23" AFF NEXT TO ASSOCIATED RECEPTACLE. 11 SECURITY ALARM KEYPAD APPROXIMATE LOCATION OF SECURITY ALARM KEYPAD ABOVE MASTER LIGHT SWITCH BANK. � 2 ROUTER ABOVE MANAGER DESK ROUTER TO BE WALL MOUNTED ABOVE MANAGER DESK. SEE DETAIL 03lE7.0. 13 SECURITYALARMPANEL SECURITY ALARM PANEL TO BE MOUNTED ABOVE MANAGERS DESK ON PHONE BOARD. COORDINATE EXACT LOCATION WITH GC. SEE DETAIL 03/E7.0. 14 PATCH PANEL EXTEND (1) CAT5E CABLE FROM PHONE JACK AT MANAGERS DESK TO PATCH PANEL. SAP#'.UIflF3GIi SNO1'r�a 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P:312.951.0600 F:312.951.0300 WWW.POTBELLY.COM �� /��_ GPD GROUP, WC. 520 South Main Street, Suite 2531 � Akron, OH 44311 330.572.2100 Fax:330.572.2102 O r �"'� � Cn � Q � J N J M � O � J � � � W � � Z �' � Z � � N � � Q � � m U � W = � � � � N � W � � Q o z � � �— U a � SHEET TITLE SYSTEMS PLAN SHEET NUMBER E4.0 LIGHTING SCHEDULE ITEM # TYPE MANUFACTURER DESCRIPTION Count MODEL LAMP FURN INSTALL VOLTS WATTS B.O. FIXTURE COMMENTS L100 DEGORATNE PENDANT -14" CON-TEC SCHOOL HOUSE FIXTURE 5 CM5601150 W/ 8' ASSEMBLY PHILIPS 11A19/END/2700/DIM 6J1 VD GC 120 23 7'-9" AFF TO BOTTOM SEE DETAIL 09/A5.2 DECORATIVE ROUND CHANDELIER WITH 10 GLOBE GLASS SHADES & 10 UPRIGHT L101 DECORATIVE CHANDELIER CUSTOM BY PSW LIGHTS 1 CUSTOM (10) LITETRONICS 13W NEOLITE CFL LAMP/ORDER CODE: NL-13427 VD GC 14 8'-3" AFF TO BOTTOM L102 ANTIQUE GLOBE FIXTURE CUSTOM BY PSW DECORATNE CHAIN HUNG FIXTURE WITH VINTAGE COLORED TEXTURE GLASS SHADE 5 CUSTOM PHILIPS EL/MDT213W VD GC 120 14 7'-9" AFF TO BOTTOM SEE DETAIL 09/A5.2 L103 WALL SCONCE JUSTICE WALL SCONCE W/ SHADE 1 POR-8921-20-PLET-DBRZ PHILIPS 11A19/END/2700/DIM 6H VD GC 42" AFF (LOW TABLES) l54" AFF (HIGH TABLES) L104 WALL SCONCE - TOILET ROOM REJUVENATION SELMA WHITE PORCELEIN 2 A4631 / B2002 SNADE PHILIPS EL/MDT 23W VD GC 120 23 CENTER FIXTURE ABOVE MIRROR AT 7'-0" AFF L109 CYLWDER PENDANT CON-TECH 6° CYIINDER PENDANT W/ 24" STEM KIT AND MONOPOWT 4 CF6-42P-GB / CSK248 f LA18-B PHILIPS PL-T 42W/835/4PIALTO VD GC 13'-0" AFF TO BOTTOM SEE DETAIL 09/A5.2 L202 CEILWG MOUNTED TOILET RM FIXTURE REJUVENATION FRANCIS BLACK PORCELEW W/ BLACK STRIPED SHADE 2 A7685 / 61489 BLACK STRIPED SHADE 23W GU24 LAMP VD GC 120 23 N1A L203 SURFACE MOUNT COOLER STRIP LIGHT METALUX VAPORITE 1 X4 STRIP LIGHT (2) LAMP 1 VT-232-120-E881 GE F28T8/SP35NMX/ECO; ORDER CODE: 00256 GC TO PROVIDE LAMPS Vp/GC GC 120 FIXTURE BY VENDOR, LAMPS BY GC L204 CEILING MOUNTED FIXTURE - BLACK REJWENATION LOMBARD BLACK ENAMEL W/ CUSTOM GREEN STRIPE SHADE 1 A0561 W/ 301GN-10 SHADE 23W GU24 LAMP VD GC 23 L207 LED TRACK NEAD (MENU) CON-TEC PAR30 ROUND BACK CYLINDER TR4CK HEAD 8 CTL230-B SOLAIS LR30LN/25/30K/18W/1000BK VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAII O7/A52 �2pg LED TRACK HEAD (WALL FLOOD) CON-TEC PAR30 ROUND BACK CYLINDER TR4CK HEAD 14 CTL230-B SOLAIS LR30LN/40/30K/18W/1000BK Vp GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L210 LINEAR TRACK FIXTURE 48" CON-TEC LINEAR SLIM STYLE WALLWASH 3 CTL14154/HO-B PHILIPS F54T5/835M0/ALTO VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TR4CK AT 13'-6" AFF SEE DETAIL 12/A5.2 METALUX 2GR8-332A-UNV-EB81-U, 2X4 (3) PHILIPS LED T8 LAMPS; PRODUCT N0: 45359-7; ORDERING CODE: 12T8/48-3500 L302 RECESSED 2 X 4 COOPER METALUX, 2X4, 3 LAMP FLUORESCENT FIXTURE 4 RECESSED IF 10/1 VD GC L310 6" RECESSED DONMLIGHT (LED} CON-TEC 6" INCADESCENT HOUSING AND TRIM 5 RL38 +CTR1902-WHT SOLAIS LR38/25/30K/1025BK VD GC 6" RECESSED DOWNLIGHT W/ WALLWASH L311 (LED) CON-TEC 6" INCADESCENT HOUSING AND WALLWASH TRIM 1 RL38 +CTR3807-WHT LR38/25/30K/1025BK VD GC L400 CEILING FAN REVOLUTION LIGHTWG MARISSA, WAW UT PECAN, NO LIGHT KIT, VENETIAN BRONZE 2 MA52VBT N/A VD GC 120 5 9'-0° AFF TO BOTTOM SEE DETAIL 14/A5.2 MOUNT TO TOP OF POST AT BOOKCASE NEAR L401 MUSICIAN LIGHT REJUVENATION 9" OPAL CONE SCHOOLHOUSE-STYLE SHADE t B6550 OPAL LITERONICS 13W NEOLITE CFL/ ORDER CODE: NL-13427 VD GC 13 MUSICIAN AREA TECHNICAL CONSUMER L500 EMERGENCY LIGHT PRODUCTS EMERGENCY LIGHT TCP 20760 Emergency 4 2076� EMERGENCY HALOGEN LIGHTS VD GC 120 6 TECHNICAL CONSUMER L502 EMERGENCY EXIT SIGN W/ LIGHTS PRODUCTS COMBO EMERGENCY EXIT SIGN W/ (2) HEADS 5 TCP 20723 VD GC L507 REMOTE HEAD FOR EXIT SIGN EXITRONIX REMOTE HEAD 2 Z1P-B PAR 36 TUNGSTEN VD GC 6 OR 12 USE WITH L506 L601 WALL MOUNTED SPEAKER SOUNDTUBE WALL MOUNT SPEAKER 2 SM4001 VD VD GC TO INSTALL BACKER BOX FOR SPEAKERS L602 CEILING MOUNTED SPEAKER LOWELL 8" DUAL CONE SPEAKER ASSEMBLY 3 R SERIES VD VD GC TO INSTALL BACKER BOX FOR SPEAKERS L610 72" EXTENSION ROD REVOLUTION LIGHTWG 72" IRON DOWN ROD - DR72V6 1 DR72VB VD GC FOR USE WITH L400 CEILWG FAN. L611 I.AMP CHANGER KIT MR. LONGARM INC. LAMP CHANGER KIT 1 886013030 VD GC L613 3' X 5' EXHAUST HOOD JD HIGGINS SS HOOD W/ 18" ENCLOSURE PANEL 2 3624 VD GC L614 4'-0" BLACK TRACK CON-TECH 4'-0" BLACK TRACK FOR LED TRACK HEADS 3 LT-0-B VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L615 6'-0" BLACK TRACK CON-TECH 6'-0" BLACK TRACK FOR LED TRACK HEADS 8 LT-6-B VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L616 8'-0" BLACK TRACK CON-TECH 8'-0" BLACK TRACK FOR LED TRACK NEADS 1 LT-8-B VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L617 TRACK END PEED CON-TECH END FEED (ONE NEEDED FOR EACH TRACK) 7 LA-10-B VD GC L618 TRACK CONNECTOR CON-TECH CONNECTOR TO FIT MULTIPLE TRACKS TOGETHER 2 LA-2-B VD GC L619 TRACK CORNER CONNECTOR CON-TECH CONNECTOR TO FIT TRACKS AT A 90 ANGLE 2 LA-12-B VD GC WILL NOT BE USED IN ALL LOCATIONS. VERIFY WITH ENGINEERING L620 CURRENT LIMITING DEVICE CON-TECH CURRENT LIMITING POER FEED 2 LA-23-RN VD GC DRAWINGS �r � SAIMU1�ffG#i SHi7i'rn, 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGO, IL. 60654 P: 312.951.0600 F:312.951.0300 NNJvV.POTBEILY.COM � /��_ GPD GROUP, INC. 520 South Main Street, Suite 2531 � Akron, OH 49311 330.572.2100 Fa�c: 330.572.2102 M � � 0 � 0 N � w m � � z � U W 0 � a SHEET TITLE LIGHTING SCHEDULE SHEET NUMBER E5.0 � C � N RP-18 L EXHAUST & SUPPLY FANS INTERLOCK SCHEMATIC r TIMECLOCK (PROVIDED BY E.C:) TIME ON - START OF BUSINESS. TIME OFF- END.OF BUSINESS. ' REFER TO DETAIL 1 ON SHEET E7.0 POR ADDITIONAL INFORMATION.. � � � � LP32 �--I�TO�KH-1/EF-1 I ' LP-34 � ��JO KH-1 / EF-1 LP-36 -I-{ �--I-► TO KH-1 / EF-1 20-AMP, 250V., 3POLE � ELECTRICALLY HELD MOTOR RATED CONTACTOR MOUNTED ABOVE PANEL M . NEMA'IENCLOSURE � � � LP38 � i-► TO RTU-2 � LP-40 � � TO RTU-2 : � LP-42 -j-{ �-jI-� TO RTU-2 104AMP, 250V., 3-POLE J J ELECTRICALLY HELD MOTOR � RATED-0ONTACTOR MOUNTED ABOVE PANEL IN NEMA'IENCLOSURE COOLER/FREEZER DOOR JAMB WIRE DIAGRAM J-BOX � �I � � ��p,NSFORM R J J (WHEN REQ'D�j i i �DIGITAL THERMOMETER (WHEN REQ'D) PROBE VAPOR PROOF LIGHT BASE d��Y� ���- � � HEATER WIRE HEATED AIR VENT (WHEN REQ'D) (WHEN REQ'D) PILOT LIGHT 115-60-1 POWER � T (� � I ( � I J-BOX (BY OTH S) BUCK OPENWG SWITCH{LIGHTS WIRE DIAGRAM J-BOX 115-60-1 POWER ' I I AT OR OPENING IY��,L. �L��it RECFJ�T )F L4RGEST i�T�3R (*� KI'f�HEN LOfit) PER �{71'E T(XTAt.ftCFi . 14.1 KW J£1.25- 13�9KW 4_4 K� JL 1:OA = 4:4 KW (3,0 K�fd X .5A = 0,9 KW 2t,a Kuu x��= zy s tewt 39_1 KW X 1.00 =� 39 9 t*.�Ar � 40:9 KVi� X 0.65 = 26.6 KW 10.5 $ KW = 293.$ RNFS i5.6 E�VY Y.25 = 3.8 KW �twa �cw= 3b4:6 nn�c $.4 Kk&i � � � � � � � � � j � ; � � � � a • . . . ' B ����� i . e � �� ����0� ��� • � � ������ 0-�--- � � ' r ' OmO� `�` �.�� m�0 ` ---�-0 0---�- � • e •' Om0 �< ��' � �. m�0 ' ' s � � • -�---0 0����� 0�' O�y'��'� �-� � ` �' m` 00 � � . _ � • • - �����0 0����� • 0�0��="m'�� m00 ' '' " �����0 0-���� � . . .. . .. Om0 ������,� �00 � ' '' ' �����m �---�- � • OmO� ; =�4 �m00 °' � • � � ° --- ° ' -m ������ � ' • � ' ����a. �� � ' ������ m����� o . . a . � . omo � � � � m�o . . . . �����m ��� �� ������ e . . . - � .. omo�� �� r . �mo� . �����m ������ ' 0�0����.�'� .". ��0 `�. '• ' ' ������ 0�����' ° Om0 ���'f� ...000' ` ��� s' �� 0����� �m0� ���_ ,�- 000 - ` - ���e�� �--�-- ' .: � . .r ' ' : • � �Y'�� ._ m�� t • � • � ' ' ---�-� m--�-� -�m� R�..:.�s:s.. ':: m�� � 0 i - � i i ---��m m--�--! ` • •• ' f ! � �m��xs��.. . t., ����� f • ' i' � ---�-m 00� - . - � �����m 0����� • .. - . - -. .. . , �_�� . . m0� - . - � �����m ������ �m�����"'�� . ... �00� ... ������ m----� � " ----�� m____� �j- . `-� omo�_ � m�o � � ____�� � � 4 �� ..�, � �� - • • - • ��� t o • ��� e • a • � e - � •�� s � ■ ��s s '� e s �e -• r s � oo . '.• �• •' o. '• `• s � • e' � �� � � ' i . •�� i � • f i • EXlS7'. PANEL ; LP ,12012{?8V, 3FH, 4 WIRE, 400 AMP BUSSINf,a, ML4 {X), MCB (}, SUl2FAGE (j, FLUSH {X), FEED-THRU LUGS {X) C:KT Lf?fiEi T6TAL PER PHP«SE fN LOAD GKT # KW # L R: HU PA K [iE9CR(PTION NO7E AA+P POLE A 6 G AMP POL€ NOTE DES�RIPTlON L R HV M K 1 6:4 LIGHTIN�-PREPAREA1k{4LLV�RY 4 2� 1 0.4 24 1 SPARE � 3 Ct.5 FLYi:iGHT 3 20 9 1,3 24 1 SI-�OWNflND4WREGEPTS t1.8 4 5 02 LiGHTING SERthCEAREA 4 2(I 1 -I.4 Zk� 1 4 S296A-'YAGOZTA�ETSIGN' 1.2 6 7 09 LIGHTIN� fllNINGTRACK 4 20 1 1.8 29 1 LIGHTIRIG CHANE?ELIER 1.4 8 N 9 6:4 LIGWTIPI� - DlNING ARfA PEEVDtWTS 4 2(� 1 1.0 2Q 1 2 Li�hf€HJG EMERGENCY £ EXIi t P1L 0:8 10 2 11 0,7 E'13p - WQRKTQP REF�IG. 3 2Q 1 0.9 20 1 4 LIGI-iGING - HOOD 1 CONTAGTC?RS 6,2 42 '13 6:5 LI�HTIN� - RES7ROORAS 4 20 1 1.1 2Q 1 3 FUTURE iT EQUIPMEM 6:6 14 95 6.3 LIGH'€I@hIGG-SERVtGEARE�TRAGK 4 2Q 9 0:8 24 1 3 E4438-FUTUREE4UIPMEPIT m:� i6 17 1.6 LIGHFIRiG - CE14_WG FANS 4 2Q 1 2.1 29 1 3 E4Q4 - FP3C Alt�GHiNE t?.5 18 �e s� zQ �� � p.c��� 20 � s��vz� 2a 29 6:4 REGEPTS - R04F Z0 9 OA 20 1 SPiiRE 22 23 0_6 P�02-ELECTf11LETS 3 20 1 4.� 2Q 1 SPRRE 24 25 0.1 R84Q - Gft.S WATER HEATER 2 20 1 0.6 0.5 26 27 0:5 E4�9A- SOdA RACK & CAR@: 3 20 1 1:Q 20 3 1 Ef-1 0.5 ZS 2J 17 R41q-TEABREUUEf2 3 2a 1 22 0.5 30 31 SPRRE 20 '1 5,2 52 �2 33 9:5 E401- SLIGER 3 20 `f B.7 SQ 3 1 RT#J-3 5.2 34 35 1:8 E427A- 6LEPIDER 3 20 9 7.D 52 3$ 37 1.$� E427& BLEN€fER 3 26 4 7.fl� 5.2 38 � 1.8 f�tfl�- FUiUk� £QUJPDl�Pff 3� 20 4� 7:ET SD 3�� 1 R7E1-�� 52 4fl 41 1,8� (G�t09-FCIfUftEEt3UIPh�Pf3' 3 2Q i� Z�4Y 52 42 FfiNEL SN/1LL BE EULtY RATED FOR 22K/1�C TOTAL= 1fi 9 182 2i,2 55.5 T4fiAt CObIN KW' 1'542 T4TAL GQNN AMPS SER�NG jPANEL'LP'j CONN tOAD DNERS4TY DEfi�AN� L6AU NOTES: ���I� L= 7;T KUV X 1:25 = 5.83 KW 1. PR6}JlDE HACR RATED GB RECEPiACLES R= 1:2 KW X 1.Q0 = 1.1& KW 2. RRGlVIDE'BREAf4ER titVfLt3GK 4fV DEI�GE HVAC' ECiUIP HV = 327 KW X 1:OQ = 32.7 KVY 3. 5mAGFCI BREAKER 25°foOFL�{GESTM4TQR HV= i5.8 KW X.25= 3.9Q KUY 4.ROUTECIRGUITTHROtlGHT#MEGLOCKfWDLTCs.CONTAGTORS �dSGELLANEi�US M= 12.3 KW X 1.00 = 122& KW KIiCHEN EQUIPMENT K= '{;7 KW Jf 4.55 = 7:092 {4W"` {•• K4TCk�N LOAD PER 2091 AIEC TABLE 22Q.58) TOTAL - 55:5 KW TQTAL = 60.7 KW TC�TAI = 1542� ANPS TCITAL = 168 7 J�S ELECTRtGA�. CONNEGTIUN SCHEE}ULE iT£NI DESGRtPTt4N VOLT�6E FtA MCA ���P CONQUGTOitS COPIDlliT DISCOPtNEtT5WITGH (1j CIRCUIT P1o. COPiAfECTtQA! NOTES PdLE RTt7-3 2fl8U 3�,4W - 44 50/3 (4j #6 CU TH W�1, (1} p16 CU C.Nd 1" 5QA/3P, 250V �USE� Di5C.5W NEMA 3R LP-32,34,36 SIZE FUSE PER MFG. SPECS. RTU-2 2fl8V-3{�,4W - 44 54(3 (4) #5 CU TH WN, (1) #1Q GU GND 1" SQAf3P, 25QV fUSED ptSC.SW NEMA 3R LP-38;40,42 StZE FUSE PER MF£,; SPEGS. EF-1 {KFE-Z� 2{38513¢,4W" 3:7 20J3 {4} #10 GU TNWN, (1J #10 fU GN[} 3J4" 34AJ3P FUSEt3 DISGSW NEMA 3R LP-25,28,30 KlT. HQODS (KH-7 j EF-2 32QV-1� 5,8 2QJ1 {Z} #10 CU THWN, (1j #10 Gt1 GidD 3J4" H.P RATED 2QR(1PTOGGLE SW. RP-23 THftU TIMECLOCKJC�NTACTOft P8Q0 GAS WATER HEATER 120ti/-1¢ 1.1 2�J1 (2) #16 GU THWN, {3) 2tSQ CU G�ID 3J4" H.P RATED 20Aj1P TOGGIf SW, LP-25 P715 GLIOLER COMPRESSOR 208V-1� 12.2' 20f2 {2) #10 �U THWN, (1) #1D CU 6ND 3j4" 3QA%2P fUSED DIS�.SW NEMA 3R RR-29,31 StZE FU4E PER MFG. SPECS. P716 fRfEZEft �[kivIPRESSOR 2Q$U-�;�# 9:7 20/2� f2j #1(1 GU TtIffJN. (�) �1D Gt3 GAID 3�4"� 30Af2P�FIlSED FiF5�,51N NEM1� 3R ftR-33,35 512E FUSE PER MFG. SPECS. NQTE. 1. E�EGTRkCALGONiRAGTORSHALLVER3FYEXACT6VERCtIRREPFfPROTfCTIONjDISCOPINEtTREQUIRE�IIEMTS{PERN.E.C.ART440jWITH'EQU4�I£MTMANUFAGTURER41i�MEPLATf�ATAUROWREGEFPTATlQBSITEARID C4MPAREWITHELECTRIfRECQ$�NEGTIONSGHEQULE, COMTACTEN�iINEERWlTHANYDfSCREP&NqES. EIECTR6CALEONTRACTORTOMA#EA[LFIAfAC ELECTRICALfk�NWEGTfiDNS. �� �, , , t i• 222 MERCHANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P: 312.951.0600 F:312.951.0300 NMMl.POTBELLY.COM �� /��_ GPD GROUP, INC. 520 South Main Sheet, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 � 0 r � �/ J � � O � J N � M � O P W � � � 0 Z� I..L � z W U tn l'�"� � � 1 � � H N � w � � Q o Z � U � �- a ,� SHEET TITLE PANEL SCHEDULES �:I��i�lll�l:l�:� ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYWG I ALL CONDUCTORS FOR VOLTAGE DROP. TENANT / EXTERIOR � INTERIOR � EXISTING FEEDERS TO EMPLOYEE SIDE OF CHIP � CABINET (OR REAR I REMAIN. (4)-#500 KCMIL PHOTOELECTRIC SERVICE LINE WALL- � CU. &(1)-#3 CU. GND., W CONTROL REFER TO PLAN) � 4" C. COORDINATE EXACT � LOCATION IN FIELD. (WHEN APPLICABLE) I . ,.., � TIMECLOCK i EXISTING FEEDERS TO � EXISTING FEEDERS TO *SEE E3.0 FOR TENANT LIGHTWG/SIGNAGE CONTROLLER: INTERMATIC MODEL #T101 ; 3'-01/8" ( �� � REMAIN. (4)-#500 KCMIL � REMAIN. (4)-#500 KCMIL O SIGNS AND LTG ELECTROMECHANICALTIMECLOCK WITH PHOTOELECTRIC COORDINATE UVITH ELECTRICAL PLAN j -- EXISTING METERWG CABINET CU. &(1)-#3 CU. GND., IN I CU. &(1)-#3 CU. GND., IN TO ELEC. PANELS QUANTITIES AND CONTROLLER. INCLUDE ALL CONTROL WIRING AS REQ'D PER W/ INTEGRAL CT'S TO REMAIN 4" C. I 4" C. LOCATIONS. MANUFACTURER. PROVIDE CONTACTORS AS REQ'D TO � PROVIDE SUFFICIENT POLES FORALL LIGHTING AND SIGNAGE. , I TIMECLOCKPOWER TIMECLOCK AND CONTACTORS TO BE PROVIDED WfIH NEMA-1 LOAQ � DRESS � EXIST. EXIST. ENCLOSURES. CIRCUITRP-18 ' � � � STATION ��STING IANDLORD WIREWAY. WIREWAY � PANEL 'T6A PANEL T6B' � --- EXISTING SERVICE GROUNDING SHALL M RENAMED RENAMED C1 SET TO TURN ON AND OFF PER PSW DIRECTION ON 24 HRS/DAY STATION a � RP °LP' BLOG SIGNS LOCK ON CIRCUIT — REMAIN. VERIFY GROUNDING IS I 208Y/120V, 208Y/120V, C1: TIME ON 4;30 PM- MIDNIGHT POWER & DATA FOR COMPLIANT WITH N.E.C. AND LOCAI FUTURE IT EQUIPMENT. � ; � i' JURISDICTION I 30, 4W 30, 4W AND 5:00 AM - 8:00 AM REFER TO ELECTRICAL � � ; � (FEED-THRU) {FEED-THRU) TIME OFF - ALL OTHER TIMES TO ELEC. PANELS C2: FUTURE USE PLAN FOR DIMENSIONS. TO MAIN SERVICE EXISTING LANDLORD WIREWAY EXISTING 400A-3P, 400AF � ENTRANCE, UTILITY RATED DISCONNECT TO I (;2 GC TO PROVIDE LEVITON a� — Q C� -- TRANSFORMER REMAIN I 8450 RECEPTACLE - (1) PER — OVEN. PLUG TO BE � EXTEWORUGHTING I EXISTING PANELS TO PERPENDICULAR TO FLO�OR � (WHEN APPLICABLE) NOTE: I REMAIN CORD & PLUG SUPPLIED BY ,, ALL WORK SHOWN IS FURNISHED AND INSTALLED CONTACTORS `�'�-' `� ' - -- -- BY LANDLORD UNLESS OTHERWISE NOTED. NOTIFY � VENDOR. ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. I LISTED LENGTHS OF FEEDERS ARE NOT TO BE REDUCED `-Q I WITHOUT THE DESIGN PROFESSIONAL'S APPROVAL FOR ACCESS PANEL i NOTE: ADHERENCE TO FAULT CURRENT REQUIREMENTS. E.C. SHALL VERIFY THAT LANDLORD HAS CONFIRMED S.C.A. AND ARGFAULT WITH POWER C0. AND PROVIDED GENERAL CONTRACTOR AND ELECTRICIAN TO REFER TO LEASING LABELS AS REQUIRED PER NEC. AGREEMENT PRIOR TO BIDDING � TIME CLOCK DETAIL � SINGLE OVEN OUTLET / BACK BOX DETAIL �� RISER DIAGRAM Scale: N.LS. SCALE: N.T.S Scale: N.T.S. . � . � � . � 120 V . � . . . GC TO MOUNT (1) EMPTY J-BOX IN EACH OF (3) NOTE: ALL CONDUfTS, CABLWG, J-BOXES & HVAC DUCTWORK PROVIDE CONTROL WIRING CENTER BAY SECTIONS ON 2X4'S. J-BOXES TO BE DEVICES SHALL BE MOUNTED IN MILLWORK STUD SAMPLING TUBE FOR FAN SHUT DOWN TYPE 1900 (1-1/2" DEEP) WITH it2" MUDRWG WALL SO NOT TO INTERFERE WITH THE GC TO PROVIDE A 1-1/2" DEEP J-BOX WITH SWGLE QUAD SIZED FOR DUCT READY TO ACCEPT DATA CONNECTION PLATE. OPERATION OF THE REMOVABLE FRONT PANEL RECEPTACLE. CIRCUIT TO BE ISOLATED DEDICATED. REFER TO INSTALL BX GONNEGTOR TO ACCEPT DATA WIRE. OF THE POS COUNTER. PANEL SCHEDULE. 1/2"Q 4#14 PHONE BOARD: LOCATED ABOVE THE (1) RETURN MANAGER'S DESK. . . � � . DUCTMOUNTED 1/2"C,4#14 � SMOKE DETECTOR PATCH PANEL 2' x 2' x 3/4" PLYWOOD w/FLAME POS END PANEL MAP�E CHASE �0550 � RETARDANT PAINT � GC TO PROVIDE �" FLEX CONDUIT (IN FLOOR OR REMOTE ANNUNCIATOR t RESEf SYSTEM - ADJACENT WALL-REFER TO DRAWINGS) T01900 BOX SENSOR, MAPLE CHASE qo537, FROM ELECTRICAL PANEL. LOCATED PER PSW DIRECTION � � � PROVIDETYPEDLABEL � � � �. � � � WDICATING"HVACDUCT � � � . — GC TO PROVIDE EMT DATA CONDUIT IN SECOND BAY OF P.O.S- SMOKE DETECTOR'. TYPE TO BE CAT 5e CABLE (8 TOTAL). PROVIDE 15 FEET OF EXCESS CAT 5e CABLE AT P.O.S & 20 FEET OF EXCESS CAT CABLE AT MANAGER'S DESK NOTE: PROVIDE DETECTOR, HOUSING, TYPE, REMOTE STATION, AND ALL ACCESSORIES. �� � DETECTOR SHALL BE INSTALLED UNDER DIVISION 15. CONNECT DETECTOR AS SHOWN. �� � WHEN PSW SPACE IS MONITORED BY CENTRAL BUILDING FIRE ALARM SYSTEM, GC TO SYSTEM - — — — — — — — — — — � COORDINATE WITH LANDLORD'S ALARM CONTRACTORTO CONNECT BUILDING ALARM SYSTEM TO DUCT DETECTORAUXILIARY CONTACTS. TERMINA �t CatSe �2 Cat5e �t Cat5e �1 Cat5e �2 Cat5e GC TO PROVIDE (2) 1" DATA CONDUIT BLOCKS I II I I MECHANICAL CONTRACTOR TO PROVIDE AND INSTAIL DUCT DETECTOR WITH MINIMUM TWO I II I I II SETS Of AUXILIARY CONTACTS � �� � � �� � �� � � (� ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL CONTROL WIRING FROM DUCT � �� � � (� DETECTORTO AC UNIT � �� � � �� 2 SECTION THRU POS COUNTER FROM CUSTOMER SIDE ��UCT SMOKE DETECTOR i ii i i ii Scale: N.T.S. Scale: N.T.S. � �� � � �� � �� ( � �� � P.O.S. �� P.O.S. � P.O.S. � P.O.S. II Z4 PORT CISCO SWITCH --� . I TERMINAL I� TERMINAL � TERMINAL I TERMINAL �� WArChP?,Nct . . . . � � � � �) WINDSTREAM ROUTER, RP-1 --__ � �-- SECURITYALARM PANEL I II ( I �� QUAD OUTLET MOUNTED ON —_ I II I I �� m MANAGER'S DATA LINES TO (� (� (�j� PHONE BOARD FOR PHONE �� —�_ �ESK MANAGER'S DESK ���� RJ45 �(2) RJ45 U(1) RJ45 � c5 U(1) RJ45 U(�) RJ11 EQUIPMENT. RP-13 �— 30" X 60" - 3(4" FRT PLYWOOD EquiP�eNT �� (1) RJ45 DEDICATED DUPLEX OUTLET FOR ��� PHONE BOARD ABOVE SHELVING, pHo�E�wc SOUND SYSTEM, RP-11 ��� PAINT TO MATCH WALL. a b c d e f g h i j PROVDE 4" SQUARE JUNCTION BOX �*"�t' ' j ;; — THERMOSTAT LOCATIONS. � � � � � � � � � � AND 1-1/4" CONDUIT TO ACCESSIBLE °'�.'�'F� PROVIDE SINGLE GANG JUNCTION 3�_z" CEILING FOR SOUND SYSTEM i 5r BOX W/ PULL STRING TO �� ����ft� � ; I ' ACCESSIBLE CEILING. PROVIDE DEDICATED QUAD OUTLET FOR �t��� � SAME NUMBER OF BOXES AS POWER SUPPLY, RP-2 ' � ;�� � � HVAC UNITS, TYP (2) STACK � � ; m� , � L, THERMOSTATS. CONTROLZONESCHEDULE NOTES: JBOX FOR FUTURE IT NEEDS — °° � 1. ALL WORKAND MATERIALS FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE. ��'" f� WALL MOUNTED PHONE �—� �„ � a- STOREFRONT LTG 2. PROVIDE PLENUM RATED CABLING FOR ABOVE THE CEILING WHERE "PLENUM RATED AIR SPACE" SYSTEMS ARE REQUIRED. � b - CHANDELIER LTG � � q�_g� (3) JBOXES FLUSH FOR VOLUME c- CEiuNc FaNs MOTORs � INDICATES SWITCH 3. PROVIDE CONDUIT FOR DATA LINES IF REQUIRED BY CODE. o, d- DINING AREA TRACK 4. DATA TERMINATION BY POTBELLY VENDOR. � 3'-4" r —� � CONTROLS. PROVIDE STAINLESS e-SERVICEAREA-PERIMETERLTGQUEING OUTLETS FOR GENERAL USE, RP-4 �' ��� I � -- STEEL BLANK PLATES FOR f- SERVICE AREA-PERIMETER LTG 5. IF NOT PROVIDED BY LL AS PART OF WORKLETTER, GC TO PROVIDE 1/2" CONDUIT AND PULL STRING FROM DEMARC (LL PHONE ROOM)SO PHONE BOARD. I �"` . I PREP AREA LTG I ' � ��hF� UNUSED OPENINGS. 9- I - . � — — � h - HALLWAY LTG � ��, i I I i- DINING PENDANTS I_ ___ � JI � I � j- LIGHTED HOOD AND EXHAUST SWITCH I � -.. 4---�i 3 MANAGER'S DESK - POWER ELEVATION g MASTER LIGHTING SWITCHBANK � P.O.S. DATA/PHONENIDEO ONE-LINE DIAGRAM Scale: N.T.S. Scale: N.T.S Scale: N.T.S. +? A�F#�.. U��l���.i �.G il �i ��1't� V A x�a 222 MERCNANDISE MART PLAZA, SUITE 2300 CHICAGQ IL. 60654 P:312.951.0600 F:312.951.0300 WWW.POTBELLY.COM � /��_ GPD GROUP, WC. 520 South Main Street, Suite 2531 � Akron, OH 44311 330.572.2100 Fax: 330.572.2102 WC G � U 1 z O � Z W � Q U � � u� 0 � 0 N � w m � � z U w O � a SHEET TITLE ELECTRICAL DETAILS SHEET NUMBER E7.0 �