Loading...
HomeMy WebLinkAboutWV076_MCKENZIE_AS-DESIGNED.pdfBUILDING FILE REPORT File Name: WV076_MCKENZIE_CODE.blg Date: September 25, 2015 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Property/Builder: Rating Building Name: WV076 Org. Name: TSI ENERGY SOLUTIONS Owner's Name: HOMES BY MCKENZIE, INC Address: P.O. BOX 705 Property Address: 1244 FRENZEL PKWY City, St, Zip: CARMEL, IN 46082 City, St, Zip: CARMEL (AS DESIGNED), IN 46032 Phone No: 317-846-4655 Phone No: Website: www.tsienergysolutions.com Builder's Name: HOMES BY McKENZIE, INC Rater's Name: DEVIN SIELSCHOTT Phone No: 317-574-8806 Rater's Email: dsielschott@tsienergysolutions.c Email Address:jmckenzie1@johnmckenziecollection.com Rater's ID: 5701119 Model: CUSTOM Provider ID: 1998-053 Development: WESTVALE 76 Sample Set ID: 0000 Permit Date/Number: Rating Date: 09-25-2015 Rating Type: Projected Rating Reason: New Home Rating No.: Registry ID: General Building Information Area of Cond. Space(sq ft): 6443 Volume of Cond. Space: 60422 Year Built: 2015 Housing Type: Single-family detached Level Type(Apartments Only): None Floors on or Above-Grade: 2 Number of Bedrooms: 3 Foundation Type: More than one type Enclosed Crawl Space Type: Unvented Thermal Boundary Location: REM Default Foundation Wall Info:1 2 3 Name COND/AMB CRAWL/AMB COND/GARAGE UNFIN Library Type R-10 Draped, 4' R-10 Draped, Full R-10 Draped, 4' Length(ft) 44.0 97.0 10.0 Total Height(ft) 9.0 3.0 9.0 Depth Below Grade(ft) 8.0 2.0 8.0 Height Above Grade(ft) 1.0 1.0 1.0 Location Cond->ambient/grnd Cond crwl->amb/grnd Cond->garage/grnd Uo Value (wall, airfilm, & soil) 0.076 0.077 0.076 Uo Value (wall assembly only) 0.911 0.094 0.878 BUILDING FILE REPORT WV076 Page 2 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Foundation Wall: R-10 Draped, 4' Type: Solid concrete or stone Thickness(in): 8.0 Studs: None Interior Insulation: Continuous R-Value: 10.0 Frame Cavity R-Value: 0.0 Cavity Insulation Grade: 1 Ins top: 0.0 ft from top of wall Ins Bottom: 4.0 ft from top of wall Exterior Insulation: R-Value: 0.0 Ins top: 0.0 ft above grade Ins bottom: 0.0 ft from bottom of wall Note: Foundation Wall: R-10 Draped, Full Type: Solid concrete or stone Thickness(in): 8.0 Studs: None Interior Insulation: Continuous R-Value: 10.0 Frame Cavity R-Value: 0.0 Cavity Insulation Grade: 1 Ins top: 0.0 ft from top of wall Ins Bottom: 0.0 ft from bottom of wall Exterior Insulation: R-Value: 0.0 Ins top: 0.0 ft above grade Ins bottom: 0.0 ft from bottom of wall Note: BUILDING FILE REPORT WV076 Page 3 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Slab Floor Info:1 Name BSMT Library Type Uninsulated Area(sq ft) 2004 Depth Below Grade(ft) 8.0 Full Perimeter(ft) 189 Exposed Perimeter(ft) 189 On-Grade Perimeter(ft) 0 Slab Floor: Uninsulated Slab Covering None Perimeter Insulation (R-Value): 0.0 Perimeter Insulation Depth (ft): 0.0 Under-Slab Insulation (R-Value): 0.0 Under-Slab Insulation Width (ft): 0.0 Slab Insulation Grade: 1 Radiant Slab: No Note: Floor Info:1 Name CRAWL Library Type Uninsulated Area (sq ft) 872 Location Btwn cond & cond (adiabatic) Uo Value 0.257 BUILDING FILE REPORT WV076 Page 4 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Floor: Uninsulated Information From Quick Fill Screen: Continous Insulation R-Value 0.0 Cavity Insulation R-Value 0.0 Cavity Insulation Thickness (in.) 0.0 Cavity Insulation Grade 1.0 Joist Size (w x h, in) 1.5 x 9.5 Joist Spacing (in oc) 16.0 Framing Factor - (default)0.1300 Floor Covering CARPET Note: Layers Paths Cavity Framing Grade Inside Air Film 0.920 0.920 0.920 Floor covering 1.230 1.230 1.230 Subfloor 0.820 0.820 0.820 Cavity ins 0.000 0.000 0.000 Continuous ins 0.000 0.000 0.000 Framing 0.000 0.000 0.000 0.000 0.000 0.000 Outside Air Film 0.920 0.920 0.920 Total R-Value 3.890 3.890 3.890 U-Value 0.257 0.257 0.257 Relative Area 0.870 0.130 0.000 UA 0.224 0.033 0.000 Total Component UA: 0.257 Total Component Area: 1.0 Component Uo: 0.257 BUILDING FILE REPORT WV076 Page 5 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Rim and Band Joist:1 2 3 Name COND/AMB COND/GARAGE COND/ATTIC Area(sq ft) 236.0 44.0 119.0 Continuous Ins 0.5 0.5 0.5 Framed Cavity Ins 15.0 15.0 15.0 Cavity Ins Thk(in) 3.5 3.5 3.5 Joist Spacing 16.0 16.0 16.0 Insulation Grade 1 1 1 Location Cond -> ambient Cond -> garage Cond -> attic Uo Value 0.061 0.061 0.061 Above-Grade Wall:1 2 3 Name COND/AMB COND/GAR COND/ATTIC Library Type G1 R-15 BATT, OSB G1 R-15 Gar Walls G1 R-15 BATT, OSB Gross Area(sq ft) 2372.00 440.00 1071.00 Exterior Color Medium Dark Dark Location Cond -> ambient Cond -> garage Cond -> attic Uo Value 0.074 0.074 0.074 BUILDING FILE REPORT WV076 Page 6 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-15 BATT, OSB Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.5 Frame Cavity Insulation (R-Value) 15.0 Frame Cavity Insulation Thickness (in) 3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in)1.5 x 3.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default)0.2300 Gypsum Thickness (in) 0.5 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.824 0.824 0.824 Gyp board 0.450 0.450 0.450 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 15.000 4.375 1.030 Continuous ins 0.500 0.500 0.500 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.276 0.276 0.276 Total R-Value 17.990 7.365 4.020 U-Value 0.056 0.136 0.249 Relative Area 0.770 0.230 0.000 UA 0.043 0.031 0.000 Total Component UA: 0.074 Total Component Area: 1.0 Component Uo: 0.074 BUILDING FILE REPORT WV076 Page 7 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-15 Gar Walls Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.0 Frame Cavity Insulation (R-Value) 15.0 Frame Cavity Insulation Thickness (in) 3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in)1.5 x 3.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default)0.2300 Gypsum Thickness (in) 1.0 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.824 0.824 0.824 Gyp board 0.900 0.900 0.900 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 15.000 4.375 1.030 Continuous ins 0.000 0.000 0.000 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.276 0.276 0.276 Total R-Value 17.940 7.315 3.970 U-Value 0.056 0.137 0.252 Relative Area 0.770 0.230 0.000 UA 0.043 0.031 0.000 Total Component UA: 0.074 Total Component Area: 1.0 Component Uo: 0.074 BUILDING FILE REPORT WV076 Page 8 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Window Information:1 2 3 Name FRONT BACK BACK SLIDER Library Type U-.29, SHGC-.27 U-.30, SHGC-.26 U-.30, SHGC-.26 U-Value 0.290 0.300 0.300 SHGC 0.270 0.260 0.260 Area(sq ft) 84.00 57.00 48.00 Orientation North South South Overhang Depth 0.0 0.0 0.0 Overhang T o Top 0.0 0.0 0.0 Overhang T o Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 Window Information:4 5 6 Name BACK SLIDER BACK SLIDER LEFT SIDE Library Type U-.30, SHGC-.26 U-.30, SHGC-.26 U-.29, SHGC-.27 U-Value 0.300 0.300 0.290 SHGC 0.260 0.260 0.270 Area(sq ft) 48.00 80.00 50.00 Orientation South South East Overhang Depth 0.0 0.0 0.0 Overhang T o Top 0.0 0.0 0.0 Overhang T o Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 BUILDING FILE REPORT WV076 Page 9 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Window Information:7 8 Name RIGHT SIDE RIGHT SIDE BSMT Library Type U-.29, SHGC-.27 U-.29, SHGC-.27 U-Value 0.290 0.290 SHGC 0.270 0.270 Area(sq ft) 62.00 16.00 Orientation West West Overhang Depth 0.0 0.0 Overhang T o Top 0.0 0.0 Overhang T o Bottom 0.0 0.0 Interior Winter Shading 0.85 0.85 Interior Summer Shading 0.70 0.70 Adjacent Winter Shading None None Adjacent Summer Shading None None Wall Assignment AGWall 1 FndWall 1 Window: U-.29, SHGC-.27 U-Value: 0.290 Solar Heat Gain Coefficient: 0.270 Note: Window: U-.30, SHGC-.26 U-Value: 0.300 Solar Heat Gain Coefficient: 0.260 Note: Door Information:1 2 Name FRONT GARAGE Opaque Area(sq ft) 24.0 20.0 Library Type Steel-urth w/brk Steel-urth w/brk Wall Assignment AGWall 1 AGWall 2 Uo Value 0.187 0.187 Door: Steel-urth w/brk R-Value of Opaque Area: 4.4 Storm Door: No Note: BUILDING FILE REPORT WV076 Page 10 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Roof Information:1 Name MAIN Library Type R-50 Blown, Attic Ceiling Area(sq ft) 2876.00 Roof Area(sq ft) 2876.00 Color Medium Radiant Barrier No Type(Attic) Attic Uo Value 0.020 Clay or Cement Tiles: No Sub Roof Ventilation: No BUILDING FILE REPORT WV076 Page 11 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Ceiling: R-50 Blown, Attic Information From Quick Fill Screen: Continous Insulation (R-Value) 37.0 Cavity Insulation (R-Value) 13.0 Cavity Insulation Thickness (in) 3.5 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Bottom Chord/Rafter Size(w x h, in)1.5 x 3.5 Bottom Chord/Rafter Spacing (in o.c.) 24.0 Framing Factor - (default)0.1100 Ceiling Type Attic Note: Layers Paths Framing Cavity Grade Inside Air Film 0.858 0.858 0.858 Gyp board 0.450 0.450 0.450 Cavity Ins/Frm 4.375 13.000 0.000 Continuous ins 37.000 37.000 37.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Outside Air Film 0.858 0.858 0.858 Total R-Value 43.541 52.166 39.166 U-Value 0.023 0.019 0.026 Relative Area 0.110 0.890 0.000 UA 0.003 0.017 0.000 Total Component UA: 0.020 Total Component Area: 1.0 Component Uo: 0.020 BUILDING FILE REPORT WV076 Page 12 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Mechanical Equipment: General Number of Mechanical Systems: 3 Heating SetPoint(F): 68.00 Heating Setback Thermostat: Present Cooling SetPoint(F): 78.00 Cooling Setup Thermostat: Present Heat: 912SA48100S17A SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity (kBtuh): 93.0 Seasonal Equipment Efficiency: 92.1 AFUE Auxiliary Electric: 756 Eae Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 100 Number Of Units: 1 Cooling Equipment: 13ACX-048-230 System Type:Air conditioner Fuel Type: Electric Rated Output Capacity (kBtuh): 48.0 Seasonal Equipment Efficiency: 13.0 SEER Sensible Heat Fraction (SHF): 0.70 Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 100 Number Of Units: 1 BUILDING FILE REPORT WV076 Page 13 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Water Heating Equipment: M250T**S Water Heater Type: Conventional Fuel Type: Electric Energy Factor: 0.90 Recovery Efficiency: 0.98 Water Tank Size (gallons): 50 Extra T ank Insulation (R-Value): 0.0 Note: Location: Conditioned area Percent Load Served: 100 Performance Adjustment: 100 Number Of Units: 1 Duct System Information: Name MAIN Heating System 912SA48100S17A Cooling System 13ACX-048-230 Supply Area(sq ft) 1304.7 Return Area(sq ft) 966.5 Conditioned Floor Area(sq ft) 6443.0 # of Registers 4 Duct Leakage Qualitative Assessment - Not Applicable Duct Leakage to Outside: 256.00 CFM @ 25 Pascals Supply Duct Leakage - Not Applicable Return Duct Leakage - Not Applicable T otal Duct Leakage: 512.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction T est Duct Information:1 2 3 Type Supply Return Supply Percent Area 40.0 40.0 30.0 R-Value 30.0 30.0 6.0 Location Attic, under insulation Attic, under insulation Conditioned space Duct Information:4 5 6 Type Return Supply Return Percent Area 30.0 30.0 30.0 R-Value 6.0 6.0 6.0 Location Conditioned space Conditioned space Conditioned space BUILDING FILE REPORT WV076 Page 14 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Infiltration and Mechanical Ventilation Whole House Infiltration Measurement Type: Blower door test Heating Season Infiltration Value: 6.00 ACH @ 50 Pascals Cooling Season Infiltration Value: 6.00 ACH @ 50 Pascals Shelter Class 4 Code Verification: Tested Mechanical Ventilation for IAQ Type: None Rate(cfm): 0 Sensible Recovery Efficiency(%): 0.00 Total Recovery Efficiency(%): 0.00 Hours per Day: 24.00 Fan Power (watts): 0.00 Ventilation Strategy for Cooling Cooling Season Ventilation: Natural Ventilation Lights and Appliances Simplified Audit Refrigerator KWh: 691 Refrigerator Location: Conditioned Dishwasher EF: 0.46 Dishwasher kWh/yr: 0 Dishwasher Capacity: 12 Dishwasher kWh/Year: 0 Range/Oven Fuel Type: Electric Induction Range: No Convection Oven: No Clothes Dryer Fuel Type: Electric Clothes Dryer Location: Conditioned Clothes Dryer Moisture Sensing: No Clothes Dryer Energy Factor: 3.01 Clothes Dryer Gas Energy Factor: 2.67 Clothes Washer Location: Conditioned Clothes Washer LER: 704.0 Clothes Washer MEF: 0.817 Clothes Washer Capacity: 2.874 Clothes Washer Electricity Rate: 0.08 Clothes Washer Gas Rate: 0.58 BUILDING FILE REPORT WV076 Page 15 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Lights and Appliances Clothes Washer Annual Gas Cost: 23.00 Percent CFLs: 0.0 Percent Fluorescent: 10.0 Percent Exterior Lights: 0.0 Percent Garage Lights: 0.0 Ceiling Fan CFM / Watt: 0.00 BUILDING FILE REPORT WV076 Page 16 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 © 1985-2015 Noresco, Boulder, Colorado. Mandatory Requirements IECC Requirements Verified IECC 04: true Verified IECC 06: true Verified IECC 09: true Verified IECC 12: false Verified IECC 15: false Verified NY-ECCC 2010: false ENERGY STAR Version 3 Checklists Thermal Enclosure Checklist: false HVAC System Quality Installation Contractor Checklist: false HVAC System Quality Installation Rater Checklist: false Water Management System Builder Checklist: false ENERGY STAR Version 3 Appliances Has Refrigerators: false Number Of Refrigerators: 0 Has Ceiling Fans: false Number Of Ceiling Fans: 0 Has Exhaust Fans: false Number Of Exhaust Fans: 0 Has Dishwashers: true Number Of Dishwashers: 1 ENERGY STAR Version 3 Basements Basement Wall Area 50% Below Grade: true Basement Floor Area: 2004 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption: false Indoor airPlus Verification Checklist: Dt d R t i B d false fl ENERGY CODE INSPECTION CHECKLIST Date: September 25, 2015 Rating No.: Building Name: WV076 Rating Org.: TSI ENERGY SOLUTIONS Owner's Name: HOMES BY MCKENZIE, INC Phone No.: 317-846-4655 Property: 1244 FRENZEL PKWY Rater's Name: DEVIN SIELSCHOTT Address: CARMEL (AS DESIGNED), IN 46032 Rater's No.: 5701119 Builder's Name: HOMES BY McKENZIE, INC Weather Site: Indianapolis, IN Rating Type: Projected Rating File Name: WV076_MCKENZIE_CODE.blg Rating Date: 09-25-2015 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. Building Information: Conditioned Area (sq ft): 6443 Conditioned Volume (cubic ft): 60422 Insulated Shell Area (sq ft): 9939 The building assemblies and the energy features listed below have been modeled to demonstrate compliance with the IECC utilizing the Simulated Performance Path. At times the energy features listed below will change in the field from what has been input in the analysis. TSI ENERGY SOLUTIONS's field inspection process will identify any changes to ensure that the home continues to meet the intent of the IECC. Reports and certificates will be furnished before CO to ensure that the house meets the intent of the IECC. Ceilings: [ ] 1.Attic: R-50 Blown, Attic (2876 s.f.) R-37.0 continuous insulation, R-13.0 cavity insulation. Name: MAIN Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Above-Grade Walls: [ ] 1. Wall: G1 R-15 BATT , OSB (2372 s.f.), Between conditioned space and ambient R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Wall: G1 R-15 Gar Walls (440 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-15.0 cavity insulation. Name: COND/GAR Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ ENERGY CODE INSPECTION CHECKLIST WV076 Page 2 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. [ ] 3. Wall: G1 R-15 BATT , OSB (1071 s.f.), Between conditioned space and attic R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/ATTIC Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Windows and Skylights: Window-to-Wall Area Ratio: 0.11 [ ] 1. Window: U-.29, SHGC-.27 (84 s.f., North), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: FRONT Orientation: North Comments/Location___________________________________________________________ [ ] 2. Window: U-.30, SHGC-.26 (57 s.f., South), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: BACK Orientation: South Comments/Location___________________________________________________________ [ ] 3. Window: U-.30, SHGC-.26 (48 s.f., South), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: BACK SLIDER Orientation: South Comments/Location___________________________________________________________ [ ] 4. Window: U-.30, SHGC-.26 (48 s.f., South), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: BACK SLIDER Orientation: South Comments/Location___________________________________________________________ [ ] 5. Window: U-.30, SHGC-.26 (80 s.f., South), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: BACK SLIDER Orientation: South Comments/Location___________________________________________________________ [ ] 6. Window: U-.29, SHGC-.27 (50 s.f., East), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: LEFT SIDE Orientation: East ENERGY CODE INSPECTION CHECKLIST WV076 Page 3 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. Comments/Location___________________________________________________________ [ ] 7. Window: U-.29, SHGC-.27 (62 s.f., West), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: RIGHT SIDE Orientation: West Comments/Location___________________________________________________________ [ ] 8. Window: U-.29, SHGC-.27 (16 s.f., West), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: RIGHT SIDE BSMT Orientation: West Comments/Location___________________________________________________________ Doors: [ ] 1. Door: Steel-urth w/brk (24 s.f.), R-Value 4.4 Comments/Location___________________________________________________________ [ ] 2. Door: Steel-urth w/brk (20 s.f.), R-Value 4.4 Comments/Location___________________________________________________________ Floors: [ ] 1. Floor: Uninsulated (872 s.f.), Between conditioned space and another (adiabatic) R-0.0 continuous insulation, R-0.0 cavity insulation. Name: CRAWL Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Foundation Walls: [ ] 1. Wall: R-10 Draped, 4' (396 s.f.), Between conditioned space and ambient/ground R-10.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Wall: R-10 Draped, Full (291 s.f.), Between conditioned crawl space and ambient/ground R-10.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: CRAWL/AMB Insulation Grade: I II III Face / Inset ENERGY CODE INSPECTION CHECKLIST WV076 Page 4 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. Comments/Location___________________________________________________________ [ ] 3. Wall: R-10 Draped, 4' (90 s.f.), Between conditioned space and garage/ground R-10.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: COND/GARAGE UNFIN Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Slab Floors: [ ] 1. Slab: Uninsulated (2004 s.f.) R-0.0 perimeter insulation, R-0.0 under slab insulation. Name: BSMT Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Rim and Band Joists: [ ] 1. Joist: COND/AMB (236 s.f.), Betw een conditioned space and ambient R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Joist: COND/GARAGE (44 s.f.), Between conditioned space and garage R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/GARAGE Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 3. Joist: COND/ATTIC (119 s.f.), Between conditioned space and attic R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/ATTIC Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Mechanical Equipment: [ ] 1. Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Make and Model Number:_____________________________________________________ [ ] 2. Cooling: Air conditioner, Electric, 13.0 SEER. ENERGY CODE INSPECTION CHECKLIST WV076 Page 5 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. Make and Model Number:_____________________________________________________ [ ] 3. Water Heating: Conventional, Electric, 0.90 EF , 50.0 Gal. Make and Model Number:_____________________________________________________ Air Leakage Control: [ ] Blower Door T est at Final __________________________ [ ] House is air-sealed so as to achieve 6.00 ACH50 or less at final blower door test. (Max CFM50 is: 6042) [ ] Visual inspection at rough for mandatory code air barrier and insulation features. INFILTRATION REQUIREMENTS FOR IECC. 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage and Insulation: [ ] Duct System 1 Leakage to Outside _________________________ and T otal Duct Leakage _________________________ [ ] Duct System 1 Leakage to Outside is specified in REM/Rate at 256.000 CFM @ 25 Pascals [ ] Duct System 1 T otal Duct Leakage is specified in REM/Rate at 512.000 CFM @ 25 Pascals DUCT LEAKAGE CODE REQUIREMENTS FOR IECC 2009 IECC Postconstruction Leakage T est: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. 2009 IECC Rough in T est with AHU: T otal Duct Leakage <= 6 CFM25 / 100 sq ft CFA. 2009 IECC Rough in T est without AHU: T otal Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Postconstruction Leakage T est: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Rough in T est with AHU: T otal Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Rough in T est without AHU: T otal Duct Leakage <= 3 CFM25 / 100 sq ft CFA. NOTES 2009 IECC ANNUAL ENERGY COST COMPLIANCE Date: September 25, 2015 Rating No.: Building Name: WV076 Rating Org.: TSI ENERGY SOLUTIONS Owner's Name: HOMES BY MCKENZIE, INC Phone No.: 317-846-4655 Property: 1244 FRENZEL PKWY Rater's Name: DEVIN SIELSCHOTT Address: CARMEL (AS DESIGNED), IN 46032 Rater's No.: 5701119 Builder's Name: HOMES BY McKENZIE, INC Weather Site: Indianapolis, IN Rating Type: Projected Rating File Name: WV076_MCKENZIE_CODE.blg Rating Date: 09-25-2015 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. Annual Energy Cost ($) 2009 IECC As Designed Heating:1217 1125 Cooling:323 261 Water Heating: 368 370 SubTotal - Used to Determine Compliance:1908 1755 Lights & Appliances: 1380 1388 Photovoltaics:-0 -0 Service Charge: 248 248 Total:3536 3391 * Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.295 Home Infiltration (Section 402.4.2):PASSES Duct Leakage (Section 403.2.2):PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 8.0%. Name:DEVIN SIELSCHOTT Signature: Organization:TSI ENERGY SOLUTIONS Date:September 25, 2015 * Design energy cost is based on the following systems: Heating: Fuel-fired air distribution, 93.0 kBtuh, 92.1 AFUE. Cooling: Air conditioner, 48.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Elec, 0.90 EF . Window-to-Floor Area Ratio: 0.07 Blower door test: Htg: 0.35 Clg: 0.35 ACHnat In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. 2009 IECC ANNUAL ENERGY COST COMPLIANCE WV076 Page 2 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. H O M E C E R T I F I E D T O M E E T T H E P R O V I S I O N S O F T H E 20 0 9 I N T E R N A T I O N A L E N E R G Y C O N S E R V A T I O N C O D E Th i s h o m e b u i l t a t 12 4 4 F R E N Z E L P K W Y , C A R M E L ( A S D E S I G N E D ) , I N by H O M E S B Y M c K E N Z I E , I N C ex c e e d s t h e m i n i m u m r e q u i r e m e n t s f o r t h e 2 0 0 9 I n t e r n a t i o n a l E n e r g y C o n s e r v a t i o n C o d e B u i l d i n g F e a t u r e s Ce i l i n g F l a t : R - 5 0 . 0 D u c t L e a k a g e t o O u t s i d e : 2 5 6 . 0 0 C F M @ 2 5 P a s c a l s Se a l e d A t t i c : N A T o t a l D u c t L e a k a g e : 5 1 2 . 0 0 C F M @ 2 5 P a s c a l s Va u l t e d C e i l i n g : N A I n f i l t r a t i o n : H t g : 6 . 0 0 C l g : 6 . 0 0 A C H 5 0 Ab o v e G r a d e W a l l s : R - 1 5 . 5 W i n d o w : U - V a l u e : 0 . 3 0 0 , S H G C : 0 . 2 6 0 Fo u n d a t i o n W a l l s : R - 1 0 . 0 H e a t i n g F u e l - f i r e d a i r d i s t r i b u t i o n , N a t u r a l g a s , 9 2 . 1 A F U E . Ex p o s e d F l o o r : N A C o o l i n g A ir c o n d i t i o n e r , E l e c t r i c , 1 3 . 0 SE E R . Sl a b : R - 0 . 0 E d g e , R - 0 . 0 U n d e r W a t e r H e a t i n g C o n v e n t i o n a l , E l e c t r i c , 0 . 9 0 E F , 5 0 . 0 G a l . Du c t : N A 09 - 2 5 - 2 0 1 5 Th e o r g a n i z a t i o n b e l o w c e r t i f i e s t h a t t h e p r o p o s e d b u i l d i n g d e s i g n d e s c r i b e d h e r e i n i s c o n s i s t e n t w i t h t h e b u i l d i n g p l a n s , s p e c if i c a t i o n s , a n d o t h e r ca l c u l a t i o n s s u b m i t t e d w i t h t h e p e r m i t a p p l i c a t i o n . T h e p r o p o s e d b u i l d i n g h a s b e e n d e s i g n e d t o m e e t t h e 2 0 0 9 I E C C r e q u i r e m e n t s in compliance with Ch a p t e r 4 b a s e d o n C l i m a t e Zo n e 5 A a n d w i t h a l l m a n d a t o r y r e q u i r e m e n t s . Na m e : DE V I N S I E L S C H O T T S i g n a t u r e : Or g a n i z a t i o n : TS I E N E R G Y S O L U T I O N S D a t e : Se p t e m b e r 2 5 , 2 0 1 5 T h e 2 0 0 9 I n t e r n a t i o n a l E n e r g y C o n s e r v a t i o n C o d e i s a r e g i s t e r e d t r a d e m a r k o f t h e I n t e r n a t i o n a l C o d e C ou n c il , I n c . ( “ I C C ” ) . No v e r s i o n o f t h i s s o f t w a r e h a s b e e n r e v i e w e d o r a p p r o v e d b y I C C o r i t s a f f i l i a t e s . RE M / R a t e - R e s i d e n t i a l E n e r g y A n a l y s i s a n d R a t i n g S o f t w a r e v 1 4 . 6 . 1