Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.3 CEILING_ELEC_DATA PLANS.pdf
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date BNR AJR EN D E A V O R CA R M E L , I N 4 6 0 3 2 CA R M E L C I T Y C E N T E R - T H E N A S H 84 6 S . R A N G E L I N E R O A D PEDCOR DESIGN GROUP LLC A1.3 CEILING/ELEC/ DATA PLANS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2016 JAMES R. STUTZMAN, AIA, Carmel, Indiana. STATE RELEASE SHEET 7 OF 8SHEET 7 E R 282216 H 11 SCALE: NTS PLAN NORTH KEY PLAN BLDG D STATE RELEASE CHECK SET 01/20/2016 01/26/2016 01/26/2016 STATE RELEASE 01/26/2016 J T GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. ELECTRICAL/DATA PLAN NOTES: FURNITURE, FIXTURES, AND EQUIPMENT SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. 5. 6. 7. 8. 4. 3. 2. 1.EP1 PROVIDE NEW ELECTRICAL AND DATA OUTLETS SHOWNS WITH AN 'N'. DATA OUTLETS TO INCLUDE HARD PIPE CONDUIT BACK TO PHONE BOARD. EP2 DUPLEX WALL OUTLET. ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +44"HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR AND ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. MECHANICAL CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. ELECTRICAL CONTRACTOR AND ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN-BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS AND ENGINEER CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. 9. ELECTRICAL JUNCTION BOX. QUAD WALL OUTLET. PROVIDE NEW ELECTRICAL PANEL AT THIS LOCATION WITH LOCKING DOOR. NOTE: IF THERE IS A LOCATION THAT REQUIRES LESS REWORK/WIRING THAT IS THE PREFERENCE. PROVIDE POWER FOR WATER HEATER. WATER HEATER TO BE HUNG FROM THE CEILING.EP3 EP4 PROVIDE RECESSED IN-FLOOR BOXES FOR POWER AND DATA AT SALES COUNTER. FLOOR BOX TO BE WIREMOLD/LEGRAND RFB4 OR EQUAL. COORDINATE INSTALLATION AND WIRING OF SECURITY AND SPEAKERS/MUSIC SYSTEMS WITH TENANT.WALL MOUNTED ELECTRICAL JUNCTION BOX. EP5 PROVIDE JUNCTION BOX ABOVE STOREFRONT FOR FUTURE SIGNAGE. INCLUDE SEPARATE CIRCUIT ON TIMER. QUAD FLOOR OUTLET/DATA FLOOR OUTLET. THERMOSTAT. PROVIDE FLOOR MOUNTED POWER/COMMUNICATIONS AS TOMBSTONES.10. 11.ALL PENETRATIONS THROUGH THE DEMISING WALL BETWEEN THE TENANT AND THE SERVICE CORRIDOR NEED TO BE FIRE RATED. USE WHITE FIRE RATED CAULK. 12.FIRE ALARM SYSTEM SHALL BE COMPATIBLE AND TIED TO THE EXISTING BUILDING FIRE ALARM SYSTEM. T J J CL CL 5' - 2 1 / 2 " 2'-6" 7'-6" WIDE ARCHED OPENING EP4 EP5 EP1 EP3 EP1 EP1 EP2 RESTROOM 104 STORAGE/ OFFICE 103 SALES COUNTER DISPLAY AREA DISPLAY AREA DISPLAY 100 DISPLAY AREA DISPLAY AREA SUITE 846 1,114 SQ. FT. DISPLAY AREA DISPLAY AREA DRESSING ROOMS 102 RETAIL 101 +132" +108" N +72" N N N N N N N N GFI J J J CLCL CL CL CL CL 3'-0"2' - 1 " 5' - 6 " 6'-0" 2'-6"4'-0"1'-7" EQ EQ 8'-0" OPEN OPEN OPEN ARCH EXISTING EXISTING EXISTINGEXISTING CP8CP1 CP3 CP9 CP2 CP2 CP3 CP4 CP4 CP4 CP5 CP6 CP6 CP6 CP7 CP10 CP11 CP9 CP9 CP12 CP12 CP12 CP12 CP13 R R J CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE. SUBCONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. ALL WALLS GO TO THE DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. GENERAL CEILING NOTES:CEILING PLAN NOTES: LOCATE NEW SMOKE DETECTORS DUE TO NEW LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. CP1 CP2 EXISTING LIFE SAFETY ITEMS TO BE REUSED, PROVIDE ANY ADDITIONAL AS REQUIRED. INCLUDE PLAN AS PART OF SUBMITTAL PROCESS. 11. 10. 9. 8. 5. 6. 7. 4. 1. 2. 3. NL D 3 NIGHTLIGHT LOCATION. THREE-WAY SWITCH. DIMMER SWITCH. TWO WAY SWITCH. CEILING MOUNTED EXIT LIGHT W/ DIRECTION MATCH EXISTING. REFLECTED CEILING LEGEND: MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR AND ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. ELECTRICAL CONTRACTOR AND ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN-BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS AND ENGINEER CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. HVAC UNITS TO BE LOCATED IN SERVICE CORRIDOR. EMERGENCY LIGHTING SHALL BE CONNECTED TO THE EMERGENCY GENERATOR. LIGHTS TO BE SURFACE MOUNTED TO FINISHED CEILING W/ CONDUIT LEFT EXPOSED, UNFINISHED, UNLESS NOTED OTHERWISE. LAMPS IN ALL FIXTURES TO BE 3500K COLOR TEMPERATURE. SUSPENDED CEILING IN THE RESTROOM TO BE: ARMSTRONG, RANDOM FISSURED, 2X2 SQUARE LAY-IN TILES WITH PRELUDE XL 15/16" GRID. LIGHTING TO BE CONTROLLED BY OCCUPANCY SENSOR. CP3 CP4 EXISTING DOWNLIGHTS TO REMAIN. PROVIDE SEPARATE CIRCUIT, TIE IN WITH TRACK LIGHTS IN DISPLAY WINDOWS. TRACK LIGHTS REMOVED DURING DEMO TO BE RELOCATED. CP5 CP6 CP7 CP8 CP9 CP10 ALL CEILINGS ARE TO BE OPEN WITH ALL EXPOSED DUCTWORK AND CONDUIT UNFINISHED TO MATCH EXISTING. DRYWALL SHELL CEILING TO BE PAINTED UNLESS NOTED OTHERWISE. CP11 2 X 2 LAY-IN GRID SUSPENSION SYSTEM TO BE: ARMSTRONG, RANDOM FISSURED WITH 15/16" PRELUDE XL GRID. NOTE: CONTACT KIM WINSHIP, CM BUCK & ASSOC., 317.759.6603 FOR ALL LIGHT FIXTURES. SEE LEGEND FOR "OR EQUAL". EXISTING 6" RECESSED DOWNLIGHT. EXISTING TRACK LIGHTS. RELOCATED TRACK LIGHTS INDICATED WITH AN "R". BATTERY BACK-UP EMERGENCY LIGHT FIXTURE TO MATCH EXISTING. PROVIDE HVAC DISTRIBUTION FROM EXISTING HEAT PUMP UNIT LOCATED IN THE SERVICE CORRIDOR. USE SPIRAL DUCT IN OPEN CEILING AREA INCLUDE FRESH AIRE AND VENTIING IN THE HVAC DESIGN. NOTE: VERIFY UNIT IS SIZED ACCORDINGLY OR PROVIDE NEW UNIT FOR THIS SPACE. EXISTING TRACK LIGHTING TO REMAIN UNLESS NOTED OTHERWISE. REPLACE ANY NON- WORKING LAMPS. PROVIDE GENERAL LIGHTING IN STORAGE ROOM TO INCLUDE OCCUPANCY SENSOR. PROVIDE THREE (3) CEILING MOUNTED JUNCTION BOXES FOR ACCENT LIGHT FIXTURES. LIGHT FIXTURES TO BE PROVIDED BY TENANT, INSTALLED BY G.C. PROVIDE LIGHTING CONTROL TIMER SYSTEM AT THIS LOCATION WITH SIX (6) ZONES. PROVIDE ONE (1) ZONE FOR THE DISPLAY WINDOW LIGHTS, ONE (1) ZONE FOR EXTERIOR SIGNAGE AND ONE (1) ZONE FOR ACCENT LIGHTS. PROVIDE EXHAUST FAN VENTED OUTSIDE THE BUILDING. R GENERAL LIGHT IN STORAGE ROOM: LA LIGHTING, IND200-2-4RSR-ELF-2E8I OR EQUAL. SURFACE MOUNTED. JUNCTION BOX. EXHAUST FAN. RECESSED LIGHT IN RESTROOM: RLE INDUSTRIES, PBL-2-232U6 WITH (2) FBO32T8 OR EQUAL. EXISTING BULKHEAD TO REMAIN.CP12 COORDINATE SPEAKER INSTALLATION W/ TENANT.CP13 NN SCALE: 1/4" = 1'-0" 2 ELEC/DATA PLAN A1.3 SCALE: 1/4" = 1'-0" 1 CEILING PLAN A1.3