Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LS.2 LIFE SAFETY PLAN.pdf
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date BNR AJR EN D E A V O R CA R M E L , I N 4 6 0 3 2 CA R M E L C I T Y C E N T E R - T H E N A S H 84 6 S . R A N G E L I N E R O A D PEDCOR DESIGN GROUP LLC LS.2 LIFE SAFETY PLAN THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2016 JAMES R. STUTZMAN, AIA, Carmel, Indiana. STATE RELEASE SHEET 4 OF 8SHEET 4 E R 282216 H 11 SCALE: NTS PLAN NORTH KEY PLAN BLDG D STATE RELEASE CHECK SET 01/20/2016 01/26/2016 01/26/2016 STATE RELEASE 01/26/2016 ENDEAVOR LIFE SAFETY & CODE SUMMARY PROJECT SUMMARY This project is a new tenant improvement project known as ENDEAVOR, occupying 1,114 square feet of the ground floor of an existing Shell and Core project known as the NASH Building (D) of Phase 2 at Carmel City Center. The ENDEAVOR project occupies approximately six percent (6%) of the ground floor area of a three (3) story building. Beneath the ground floor and separated with a 1-hour fire resistive assembly, is an enclosed basement parking level. The ENDEAVOR project is a Group M occupancy, and the construction type of this project and the shell and core is V-A. The entire facility is fully protected by an automatic sprinkler system, and is surrounded by at least 30 feet of yard space on three sides. The ENDEAVOR tenant is a Mercantile Occupancy providing a Boutique retail experience for the residences of Carmel. APPLICABLE CODES & STANDARDS Indiana General Administrative Rules (675 IAC 12) 2006 Indiana Building Code (IBC 2012) 2014 Accessibility-‐Indiana Building Code (ANSI A117.1-‐2009) 2014 Minimum Design Loads for Buildings (ASCE 7-‐2010) 2014 Indiana Plumbing Code, 2012 Edition (IPC 2006) 2012 Indiana Mechanical Code, 2014 Edition (IMC 2012) 2014 Indiana Electrical Code, 2008 Edition (NFPA 70-‐2008) 2009 Indiana Fuel Gas Code, 2014 Edition (IFGC 2012) 2014 Indiana Fire Code (IFC 2012) 2014 Indiana Energy Conservation Code (ASHRAE 90.1 2007) 2010 NFPA 10-2010 Portable Fire Extinguishers 2012 NFPA 13-‐2010 Installation of Fire Sprinkler Systems 2012 NFPA 72-‐2010 National Fire Alarm Code 2014 NFPA 90A-‐ Installation of Air Conditioning & Ventilating Systems 2015 NFPA 90m — Installation of Warm Air Heating & Air Conditioning Systems 2015 ADA Standards for Accessible Design 2010 OCCUPANCY CLASSIFICATIONS: ENDEAVOR Tenant: Group M Building Shell & Core: Group R-2; Group A-2 and 3; Group B; Group M Parking Garage: Group S-2 OCCUPANT LOAD ENDEAVOR Total Gross Area 1,114 sq ft M Occupancy 1,114 sf @ 30 sf/person 37 persons CONSTRUCTION TYPES: ENDEAVOR Tenant: Type V-A Building Shell & Core: Type V-A Parking Garage: Type I-A BUILDING AREAS: ENDEAVOR Tenant: 1,114 sf Shell & Core: (Ground Floor) 17,835 sf Shell & Core: (Total Building D) 53,327 sf Shell & Core: (Incl. Garage) 68,727 sf FIRE RESISTANCE ENDEAVOR Tenant & Shell & Core (Ground Floor): Walls: 1 hour Exit Passageways: 1 hour Fire walls: 1 hour Exit Access Corridors: 1 hour Floor: 1 hour (Separating M and S-2) Ceiling: 1 hour (Separating M and R-2) INTERIOR FINISHES ENDEAVOR Tenant & Shell & Core (Ground Floor): Vertical Exits & Passageways: Class B Exit Access Corridors Class C All Others Class C FIRE PROTECTION 100% protection by an automatic sprinkler system per NFPA 13-2010 100% protection by a fire alarm & annuciator system meeting NFPA 72-2010 ACCESSIBILITY REQUIREMENTS All tenant restrooms comply with ICC/ANSI A117.1-2009; Section 604.5.1 LIFE SAFETY NOTE: 1. ENSURE TACTILE EXIT SIGNAGE INSTALLED BY ALL EXITS AS REFERENCED BY NFPA 101, CHAPTER 7 2. A PUBLIC PAKING GARAGE EXISTS BELOW THE TENANT SPACE; PER LANDLORD CONSTR. DRAWINGS,AN EXST'G 1-HR. RATED FLOOR ASSEMBLY IS PROVIDED THAT INCLUDED THAT INCLUDES A FIRE EXTINGUISHING SYSTEM AT PARKING GARAGE LEVEL; TENANT G.C. TO MAINTAIN EXST'G RATED CONDITION. 3. RESIDENTIAL OCCUPANCIES EXISTS ABOVE THE TENANT SPACE; PER LANDLORD CONST. DRAWINGS, AN EXST'G 1-HR. RATED CEILING FLOOR ASSEMBLY IS PROVIDED THAT INCLUDES A FIRE SPRINKLER SYSTEM AT FIRST FLOOR TENANT LEVEL; TENANT G.C. TO MAINTAIN EXST'G RATED CONDITION. RESTROOM 104 STORAGE/ OFFICE 103 DISPLAY 100 SUITE 846 1,114 SQ. FT. DRESSING ROOMS 102 RETAIL 101 51 ' - 5 " N SCALE: 1/4" = 1'-0" 1 LIFE SAFETY PLAN LS.2 LEGEND EGRESS PATH, POINT OF BEGINNING EGRESS PATH, POINT OF EXITING EGRESS PATH, DISTANCE TRAVELX'-X"