HomeMy WebLinkAbout700_3550_ME101.pdf1 ALL EXISTING DEVICES, EQUIPMENT, LIGHTING, ETC IN THIS
AREA ARE EXISTING TO REMAIN, UNLESS OTHERWISE NOTED.
CONTRACTOR SHALL MAINTAIN CIRCUITING THROUGHOUT
DURATION OF WORK.
EXISTING POWERWALL WITH PANELS 'A', 'C', 'DP', 'FUEL', 'H' & 'S'
TO REMAIN. REWORK EXISTING PANELS AS REQUIRED.
{EXISTING OCCUPANCY SENSOR AND ASSOCIATED POWER
PACK TO BE RELOCATED. E.C. SHALL REMOVE ALL EXISTING
ASSOCIATED WIRING AND PROVIDE NEW PER
MANUFACTURER'S REQUIREMENTS TO ACCOMPLISH NEW
LIGHTING CONTROL SCHEME SHOWN ON NEW WORK PLAN.
PROVIDE ALL MATERIAL AND LABOR REQUIRED TO MOUNTED
OCCUPANCY SENSOR IN NEW LAY-IN CEILING}.
E.C. SHALL REMOVE EXISTING LIGHT FIXTURE INCLUDING ALL
ASSOCIATED WIRING, JUNCTION BOXES, MOUNTING
HARDWARE, ETC. EXISTING CIRCUIT SHALL BE MAINTAINED
FOR REUSE WITH NEW WORK PROVIDED EXISTING CIRCUITING
IS IN CODE-COMPLIANT CONDITION. EXISTING CIRCUIT
IDENTIFICATION IS SHOWN FOR REFERENCE ONLY - FIELD
VERIFY.
E.C. SHALL PROVIDE NEW RECESSED LED 2'X'4' FIXTURE TO
EXACTLY MATCH EXISTING NEARBY PREP FOODS AREA
FIXTURE IN ALL CHARACTERISTICS. NEW FIXTURE SHALL BE
CIRCUITED TO EXISTING LOCAL CIRCUIT. EXISTING CIRCUIT
IDENTIFICATION IS SHOWN FOR REFERENCE ONLY - FIELD
VERIFY. PROVIDE ALL MATERIAL AND LABOR REQUIRED TO
EXTEND EXISTING CIRCUIT TO NEW LIGHTING FIXTURES OR
PROVIDE NEW IF EXISTING WIRING IS NOT IN CODE-COMPLIANT
CONDITION. PROVIDE NEW CONTROL WIRING AS REQUIRED
FOR USE WITH RELOCATED OCCUPANCY SENSOR.
{REMOVE EXISTING REGISTER INCLUDING ASSOCIATED,
SUPPORTS, HANGERS, ETC. AND CAP DUCT AIRTIGHT AT MAIN.
REMOVE EXISTING DUCT INCLUDING ASSOCIATED SUPPORTS,
HANGERS, ETC. AS INDICATED ON PLAN.
CONNECT RELOCATED S.A. REGISTER TO EXISTING MAIN DUCT
AS SHOWN. CONFIRM EXACT LOCATION IN FIELD PRIOR TO ANY
WORK.
INSTALL NEW DIFFUSER IN LOCATION SHOWN ON PLAN.
EXTEND NEW DUCT RUNOUT AS SHOWN TO NEW DIFFUSER
LOCATION. VERIFY EXACT LOCATION AND SIZE IN FIELD PRIOR
TO ANY WORK.}
ELECTRICAL CODED NOTES:
A)