Loading...
HomeMy WebLinkAbout15100134 Building PlansProject Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 46 0 3 2 GO D B Y H E A R T H & H O M E Drawn By Checked ByPrint Date Revisions: 08/18/2015 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 20 0 S O U T H R A N G E L I N E R O A D IN D I A N A D E S I G N C E N T E R SU I T E 1 1 3 10/12/15 Construction Set A1.2 REFLECTED CEILING/ ELECTRICAL PLAN Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 10/12/15 CONSTRUCTION DOCUMENTS 08/18/2015 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP. c COPYRIGHT 2015 JAMES R. STUTZMAN, CARMEL, INDIANA BNR MC 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. GENERAL ELECTRICAL/DATA NOTES: PROVIDE FLOOR MOUNTED POWER/COMMUNICATIONS AS FLUSH. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX CONDUIT AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. CONDUIT TO EXTEND TO THE DECK ABOVE. PEDCOR IT TO INSTALL WIRING FROM ALL DATA OUTLETS TO NORTHEAST CORNER OF THE OFFICE. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. 7. 9. 10. 11. 6. 5. 4. 3. REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. DUPLEX WALL OUTLET. FLOOR MOUNTED FLUSH MOUNT TELEPHONE OUTLET. ELECTRICAL/DATA LEGEND: PHONE/DATA WALL OUTLET (BOX CONDUIT AND PULL STRING). +44" E HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. DENOTES EXISTING OUTLET LOCATION. FLOOR MOUNTED FLUSH MOUNT DUPLEX OUTLET. 8. EP1 EP2 LOCATION OF EXISTING ELECTRICAL PANEL. EP3 ALL PENETRATIONS THROUGH THE DEMISING WALL NEED TO BE FIRE RATED. USE WHITE FIRE RATED CAULK. FIRE ALARM SYSTEM SHALL BE COMPATIBLE AND TIED TO THE EXISTING BUILDING FIRE ALARM SYSTEM. NOT USED. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. 1. 2.ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. EP4 PROVIDE DEVICES AND COVER PLATES IN EXISTING JUNCTION BOXES AS PART OF BUILDING SHELL WORK. QUAD WALL OUTLET. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. GENERAL CEILING NOTES:CEILING PLAN NOTES: PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. CP1 EXISTING BULKHEAD TO REMAIN. 8. 5. 6. 7. 4. 1. 2. 3. REFLECTED CEILING LEGEND: ALL WALLS GO TO 11'-0" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. LOCATE NEW SMOKE DETECTORS DUE TO NEW LIGHT FIXTURE LAYOUT. INFORM ARCHITECT AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CEILINGS TO REMAIN OPEN WITH ALL EXPOSED HVAC UNITS, DUCTWORK, AND CONDUIT TO BE PAINTED. CP2 CP3 CONTROL LIGHTING FROM THIS LOCATION. PROVIDE A SEPARATE SWITCH FOR EACH FIXTURE TYPE. GROUP SWITCHES TOGETHER IN ROWS NO LONGER THAN FOUR (4) ACROSS. CP4 NOTE: INSTALL HVAC UNIT AND DUCTWORK AS PART OF BUILDING SHELL WORK. PROVIDE OPEN CEILING WITH SPIRAL DUCT, HARD PIPE CONDUIT FOR ALL WIRING, AND ALIGNMENT OF ALL VISIBLE ITEMS. PROVIDE NEW DRYWALL BULKHEAD W/ 12" LIP. GYPSUM BOARD CLOUD TO BE PAINTED P3. INDICATION DUAL-LITE TO BE: MERCURY LIGHTING MER-ELXTE OR EQUAL. CEILING MOUNTED EXIT LIGHT W/ DIRECTION CP7 NOTE: TENANT TO PAINT THE CEILING. CP5 PROVIDE NEW HEADER WALL ABOVE STOREFRONT GLASS. CP6 PROVIDE NEW DRYWALL CEILING CLOUD W/ 6" LIP. MOUNT @ 10' AFF. GYPSUM BOARD CEILING TO BE PAINTED P3. A B C RECESSED DOWNLIGHTS TO BE: CREE, LR6-10L-35K-120V-DR W/ RC6-GU24 MINI-PENDANT LIGHT FIXTURES TO BE: DOT AND BO, SAVVY PENDANT LIGHT W/ 9W LED REPLACEMENT LAMP (3500K). D ACCENT PENDANT LIGHT FIXTURE TO BE: DESIGN WITHIN REACH, NELSON SAUCER PENDANT LAMP-MED #0096 - WHITE. RELOCATED TRACK LIGHTS. F EP1 EP2 EP4 EP4 EP4 EP4 EP4 EP4 OFFICE 104 INTERIOR WINDOW DISPLAY 100 EXTERIOR WINDOW DISPLAY 105 COFFEE BAR 102 SHOWROOM 101 SHOWROOM 103 +72" +72" +72" +72" E +72" +72" +72"+72" +72" +72" E E E E +72" E E +72" +72" E +72" +72" E +72" E +72" E +72" E +48" +34"4 A1.4 - 4 A1.4 2 A1.4 2 A1.4 3 A1.4 3 A1.4 2'-6" 2'-6" 9'-0" 4' - 0 " 9'-0" 4' - 0 " 10' 9' OPEN OPEN 9' 10' CP2 CP1 CP4 CP5 CP5 CP6 CP7 CP7 EXISTING RELOCATED EXISTING RELOCATED CP4 CP3 CP3 B B B B B B B B B B B B C C D E E E EE B B B B B B B B B B B B B B B N N SCALE: 1/8" = 1'-0" 2 ELECTRICAL PLAN A1.2SCALE: 1/8" = 1'-0" 1 REFLECTED CEILING PLAN A1.2 SUITE 113 Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 46 0 3 2 GO D B Y H E A R T H & H O M E Drawn By Checked ByPrint Date Revisions: 08/18/2015 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 20 0 S O U T H R A N G E L I N E R O A D IN D I A N A D E S I G N C E N T E R SU I T E 1 1 3 10/12/15 Construction Set A1.3 ENLARGED PLAN/ ELEVATIONS Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 10/12/15 CONSTRUCTION DOCUMENTS 08/18/2015 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP. c COPYRIGHT 2015 JAMES R. STUTZMAN, CARMEL, INDIANA BNR MC 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. 3'-0" 7' - 0 " D1 HARDWARE SIZE RO O M N A M E OP E N I N G NU M B E R WID T H HE I G H T EL E V A T I O N MA T E R I A L TH I C K DOOR MA T E R I A L EL E V A T I O N FRAME REMARKS D O O R S C H E D U L E P = P U L L OFFICE104 1/2"7'-0"3'-0"GL D1 D1 P, RH RH = R E C E S S E D HIN G E S 11'-3 3/4"2'-6" 2'-6" 2'-6" 11'-3 1/8" 3' - 6 " 4'-2 1/8" 2" 1' - 3 / 8 " 1/ 4 " 1' - 3 / 8 " 1/ 8 " 1' - 3 / 8 " 1" 1 1 / 2 " 3/4" MDF SUBSTRATE. 3/4" PLASTIC LAMINATE COUNTERTOP WITH 1-1/2" LIP AND 4" BACKSPLASH BOTH SIDES. COLUMN BEYOND. PLASTIC LAMINATE CABINET W/ DRAWERS. PULLS TO BE: MOCKETT DP54B W/ MATTE CHROME FINISH. 3' - 6 " 4'-2 1/8" CABINETS BEYOND. 3/4" PLASTIC LAMINATE COUNTERTOP WITH 1-1/2" LIP AND 4" BACKSPLASH BOTH SIDES. COLUMN BEYOND. SUPPORT. 10 A1.3 9 A1.3 6'-2 1/4"1'-0"2'-0" 3/4" PLASTIC LAMINATE COUNTERTOP WITH 1-1/2" LIP BOTH SIDES AND 4" BACK SPLASH. 1" FULL PLASTIC LAMINATE END PANEL WITH LEVELERS. PLASTIC LAMINATE SUPPORT. PAINTED DRYWALL COLUMN WRAP. PLASTIC LAMINATE BASE CABINET WITH SLIDING DRAWERS AND CHROME PULLS. REFRIGERATOR BY TENANT. 10 A1.3 9 A1.3 6'-2 1/4"3'-0"1'-11 1/8"7" 3' - 6 " 3/4" PLASTIC LAMINATE COUNTERTOP WITH 1-1/2" LIP BOTH SIDES AND 4" BACK SPLASH. 1" FULL PLASTIC LAMINATE END PANEL WITH LEVELERS. PLASTIC LAMINATE SUPPORT. PLASTIC LAMINATE BASE CABINET WITH SLIDING DRAWERS AND CHROME PULLS. PAINTED DRYWALL COLUMN WRAP. SCALE: 1/2" = 1'-0" 1 ENLARGED OFFICE A1.3 SCALE: 1 1/2"= 1'-0" 5 BOX BOX FILE SECTION A1.3 SCALE: 1 1/2"= 1'-0" 6 FILE FILE SECTION A1.3 SCALE: 1 1/2"= 1'-0" 4 COUNTER TOP BRACKET A1.3 SCALE: 1/2" = 1'-0" 3 OFFICE ELEVATION A1.3 SCALE: 1/2" = 1'-0" 2 OFFICE ELEVATION A1.3 SCALE: 1 1/2"= 1'-0" 9 COFFEE BAR SECTIOIN A1.3 SCALE: 1 1/2"= 1'-0" 10 COFFE BAR SECTION A1.3 SCALE: 1/2" = 1'-0" 8 COFFEE BAR ELEVATION A1.3 SCALE: 1/2" = 1'-0" 7 COFFEE BAR ELEVATION A1.3 SUITE 113 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 46 0 3 2 GO D B Y H E A R T H & H O M E Drawn By Checked ByPrint Date Revisions: 08/18/2015 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 20 0 S O U T H R A N G E L I N E R O A D IN D I A N A D E S I G N C E N T E R SU I T E 1 1 3 10/12/15 Construction Set A1.4 ENLARGED PLAN/ ELEVATIONS Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 10/12/15 CONSTRUCTION DOCUMENTS 08/18/2015 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP. c COPYRIGHT 2015 JAMES R. STUTZMAN, CARMEL, INDIANA BNR MC 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. 2 A1.4 10 ' - 0 " 1' - 0 " 1' - 6 " 1' - 6 " EQUAL 3'-0"3'-0"EQUAL VARIES. SEE PLAN. DIVIDER BY TENANT. CABINET BY TENANT. TV MONITOR BY TENANT. COVE BASE BY TENANT. PAINTED DRYWAL. PAINTED DRYWALL BULKHEAD WITH RECESSED DOWNLIGHTS. 5 A1.4 1' - 0 " 1"2'-5" 1' - 6 " 3' - 0 " 5' - 0 " +10'-0" AFF PAINTED GYPSUM BOARD BULKHEAD. METAL FRAMING. RECESSED LIGHT FIXTURE. STORAGE CABINET BY TENANT. COVE BASE BY TENANT. DIVIDER BY TENANT. TV BY TENANT. BLOCKING. BLOCKING. 6" 10'-0" METAL FRAMING @ 16" O.C. 5/8" PAINTED GYPSUM BOARD. SUSPENSION WIRE TO DECK ABOVE. METAL FRAMING. 5/8" PAINTED GYPSUM BOARD. SUSPENSION WIRE TO DECK ABOVE. WOOD BLOCKING. ALUMINUM CHANNEL. 1/2" TEMPORED GLASS WITH 3M VINYLY ON INSIDE. WOOD BLOCKING. ALUMINUM CHANNEL. PARTIAL HEIGHT WALL. SCALE: 1/2" = 1'-0" 1 DISPLAY ELEVATION A1.4 SCALE: 1 1/2"= 1'-0" 2 TYPICAL DISPLAY SECTION A1.4 SCALE: 1 1/2"= 1'-0" 3 CLOUD CEILING SECTION A1.4 SCALE: 1 1/2"= 1'-0" 4 WALL/GLASS/BULKHEAD SECTION A1.4 SCALE: 1 1/2"= 1'-0" 5 TYPICAL DISPLAY BULKHEAD A1.4 SUITE 113NOT USED Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 46 0 3 2 GO D B Y H E A R T H & H O M E Drawn By Checked ByPrint Date Revisions: 08/18/2015 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 20 0 S O U T H R A N G E L I N E R O A D IN D I A N A D E S I G N C E N T E R SU I T E 1 1 3 10/12/15 Construction Set D1.1 DEMOLITION PLAN Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 10/12/15 CONSTRUCTION DOCUMENTS 08/18/2015 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP. c COPYRIGHT 2015 JAMES R. STUTZMAN, CARMEL, INDIANA BNR MC 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. DP2 DP2 DP1 DEMOLITION LEGEND: EXISTING CONSTRUCTION TO BE REMOVED. EXISTING PARTITION TO REMAIN. EXISTING TRACK LIGHTS TO BE REMOVED. SAVE FOR REUSE. EXISTING PENDANT LIGHT TO REMOVED. DENOTES AREA NOT IN CONTRACT. REMOVE EXISTING PENDANT LIGHT FIXTURES. SAVE LIGHTS FOR OWNER'S REUSE. REMOVE EXISTING TRACK LIGHT FIXTURES. SAVE LIGHTS FOR OWNER'S USE. DEMOLITION PLAN NOTES: REMOVE ELECTRICAL AND DEVICE LINES IN WALLS THAT ARE TO BE REMOVED, INCLUDING ALL ATTACHED WIRING. DEMOLISH ELECTRICAL DEVICES AND WIRING BACK TO A POINT WHEREAS PROPER PREPARATION FOR NEW FINISHES IS POSSIBLE. SEE ELECTRICAL AND FINISH PLANS FOR FURTHER INFORMATION. SAVE ALL ITEMS REMOVED FROM THE SPACE PER OWNER'S DIRECTION UNLESS NOTED OTHERWISE. 2. 1. GENERAL DEMOLITION NOTES: DP2 DP1 N SCALE: 1/8" = 1'-0" 1 DEMOLITION CEILING PLAN D1.1 SUITE 113 ti g'�`np�fure RE: Indiana Design Center Godby Hearth & Home Suite 113 INCLUDES ADDENDUM Ol, �2, 03. & 04 filsfi�. D:e3�cr�pi�ai� Af Wotk Division Ol - General Conditions 101 General Conditions Division 06 - Cabinetry & Millwork 103 Cabinets & Countertops Division 07 - Thermal � Moisture Protection 107 Caulk and Sealants Division 09 - Finishes 111 Metal Studs, Drywall, Blocking 1 11.2 Glass walls 112 Drywall Division 10 - Specialties 117 Fire Extinguisher Cabinet Division 21 - Fire Suppression 122 Fire Suppresion Re-work Division 26 - Electrical 127 General Electrical, Demo, Floor boxes 128 Lighting 129 Fire Alarm Project Estimate Sub Total 130 Project Overhead & Profit Project Estimate Total Tenant Provided 111.1 Drywall Dividers 115 Painting 115.1 Paint Open Ceiling 114 Flooring 10.9.15 Square Foot 1466 7l�C-�irit�tied'::�k': ;13t�kec�F� $ 1,871.00 $ 1.28 $ 3,390.00 $ 2.31 $ 750.00 $ 0.51 $ 2,846.00 $ 1.94 $ 1,236.00 $ O.B4 $ 2,620.00 $ 1.79 $ 450.00 $ 0.31 $ 987.00 $ 0.67 $ 5,325.40 S 3.63 $ 1fi.37fl.0� $ 11.17 $ 1,35a.D0 $ 0.93 $ 37,205.00 $ 25.38 $ 37,205.00 25.38 n $ 1,770.00 $ 1.21 a $ 2,860.00 $ 1.95 {f � 2,350.00 3 1.60 $ 2,055.00 $ 1.40 �J �� ` �� `°� r �U`� Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 46 0 3 2 GO D B Y H E A R T H & H O M E Drawn By Checked ByPrint Date Revisions: 08/18/2015 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 20 0 S O U T H R A N G E L I N E R O A D IN D I A N A D E S I G N C E N T E R SU I T E 1 1 3 10/12/15 Construction Set T1.1 TITLE SHEET Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 10/12/15 CONSTRUCTION DOCUMENTS 08/18/2015 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP. c COPYRIGHT 2015 JAMES R. STUTZMAN, CARMEL, INDIANA BNR MC 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. PLAN NORTH PLAN NORTH ARCHITECT: PEDCOR DESIGN GROUP, LLC 355 CITY CENTER DRIVE CARMEL, INDIANA 46032 PHONE: (317) 705-7979 FAX: (317) 705-7980 DRAWING INDEX T1.1 Title Sheet T1.2 Specifications T1.3 Lower Level Life Safety Plan T1.4 1st Floor Life Safety Plan T1.5 2nd Floor Life Safety Plan D1.1 Demolition Plan A1.1 Construction/Finish Plans A1.2 Reflected Ceiling/Elec/Data Plans A1.3 Elevations/Details 1 A1.1 SECTION CUT WINDOW NUMBER DOOR NUMBER ROOM NAME & NUMBER ELEVATION REFERENCE 1 A1.1 SECTION REFERENCE DETAIL REFERENCE REFERENCE SYMBOLS 1 A1.1 WHICH DETAIL APPEARS INDICATES SHEET IN INDICATES DETAIL NUMBER A 1 A1.1 EL. = 100'-0" T.O. FINISHED FLOOR ELEVATION MARK 1 A1.1 100 OFFICE 100 SCALE: 1/8" = 1'-0" PLAN OWNER: INDIANA DESIGN CENTER, LLC 770 3RD AVE., SW CARMEL, INDIANA 46032 VICINITY MAP SITE MAP GODBY HEARTH & HOME INDIANA DESIGN CENTER CONSTRUCTION SET SUITE 113 Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 46 0 3 2 GO D B Y H E A R T H & H O M E Drawn By Checked ByPrint Date Revisions: 08/18/2015 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 20 0 S O U T H R A N G E L I N E R O A D IN D I A N A D E S I G N C E N T E R SU I T E 1 1 3 10/12/15 Construction Set T1.2 SPECIFICATIONS Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 10/12/15 CONSTRUCTION DOCUMENTS 08/18/2015 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP. c COPYRIGHT 2015 JAMES R. STUTZMAN, CARMEL, INDIANA BNR MC 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. CONTRACT EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES AND ALARMS THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS ADDITIONAL CHARGE TO THE PARTY AFFECTED. ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR ELEVATORS, TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, LIGHT FIXTURES ( CATALOG CUTS ). PAINT ( 6" X 6" ON ACTUAL SURFACE ). ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND "FURNISHED AND/OR INSTALLED" ITEMS. CONTRACTOR SHALL INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON-REGULAR WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN SUBMIT THE FOLLOWING INFORMATION: 1.8 1.7 1.6 AGENT. 1.5 .5 .4 DOORS, FRAMES AND HARDWARE..3 .2 METAL FABRICATIONS..1 FOLLOWING ITEMS: 1.4 WORKMANSHIP. 1.3 1.2 1.1 GENERAL REQUIREMENTS1 MANUFACTURER'S RECOMMENDATIONS. 0.7 INTERPRETATION. FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI EQUIPMENT, PROVIDE FIRE-RETARDANT TREATED PLYWOOD PANELS, APA PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, STANDARDS. JURISDICTION. CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH PLYWOOD WITH FIRE-RETARDANT CHEMICALS TO COMPLY WITH AWPA FIRE-RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND C-D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32". CONTENT. .1 6.4 6.3 6.2 GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE WOOD AND PLASTIC REQUIRED TO COMPLETE WORK. METAL FABRICATIONS DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE RECORD SEPIA TO SERVE AS PART OF THE "AS-BUILT" SET. 6.1 6 5.1 5 2.11 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE- CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURIING CONSTRUCTION OR EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING IN SCOPE OF CONTRACT. 2.10 2.9 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS NOTED TO BE REPAIRED. FINISHES. ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED ON EXISTING-CONSTRUCTION-TO-REMAIN, THOROUGHLY REMOVE DRAWINGS. BE INCLUDED. 2.7 2.8 2.6 2.5 2.4 "TREMCO ACRYLIC LATEX 834"; TREMCO, INC. "SONOLAC"; SONNEBORN BUILDING PRODUCTS "AC-20"; PECORA CORP. "CHEM-CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV. ACRYLIC-EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS "PROGLAZE WHITE"; TREMCO CORP. 8.1 DOORS AND WINDOWS8 .4 .3 .2 .1 SURFACES: 7.2 .5 .4 "863 #345 WHITE"; PECORA CORP. "SCS 1702 SANITARY"; GENERAL ELECTRIC CO. "DOW CORNING 786"; DOW CORNING CORP. FIXTURES AND JOINTS IN TOILET ROOMS: ONE-PART MILDEW-RESISTANT SILICONE SEALANT - AT COUNTERS, GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL WIDTH NOT TO EXCEED 1/8 U.O.N. JOINTS BEWTEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM STRAIGHT WITH NO DISTORTIONS. INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND .3 .2 .1 7.1 JOINT SEALERS7 OUTLETS. 6.11 6.10 6.9 CASEWORK: SEMI RECESSED, DUO-PANEL, FIELD PAINTED. BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES, FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO .1 12.1 10.1 YORKTOWNE CABINETS.3 MERILLAT INDUSTRIES, INC..2 IMPERIAL CABINET CO., INC..1 FOLLOWING: MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE SPECIALTIES WITHOUT WRINKLES, GAPS OR OVERLAPS. WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND ACRYLIC LATEX ENAMEL SATIN FINISH: 10 .2 .1 9.11 A. 1. A. WOOD FLOORS:12. 2. SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6" FROM OUTSIDE CORNERS. ACCEPTABLE. KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT PRIMER-SEALER. PRIMER: 1 COAT #51701 WONDER-PRIME LATEX LATEX SATIN ENAMEL. FINISH: 2 COATS #35XX WONDER TONE ACYRLIC NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1997 EDITION, 0.6 GOVERN THE WORK. 0.5 SPECIFIED CAPACITIES OF THE EQUIPMENT. 0.4 PROJECT. 0.3 RULES AND REGULATIONS. 0.2 CONTRACTOR'S RESPONSIBILITY. 10.1 WORKMANSHIP. 3.14 3.7 3.3 PROCEEDING WITH CONSTRUCTION. 3.2 AS FOLLOWS: 0.1 CONTRACT CONDITIONS0 SPECIFICATIONS AND GENERAL NOTES WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR WORK. EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE 2.3 2.2 2.1 DEMOLITION THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL REQUIREMENTS. EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT HOISTING, CARTING, ELEVATOR SERVICE, STANDARD AND OVERTIME 2 1.12 1.11 OPERATING FOR TEN DAYS. WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH OR EQUAL. SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF MANUFACTURED BY KNAPE & VOGT. HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS WITH POSITIVE STOP AND LOCKOUT POSITION, WITH DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES 6.8 6.7 .5 .4 MANUFACTURED BY STANLEY. MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH #4483 OR EQUAL AS MANUFACTURED BY STANLEY. PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER, BY GRASS OR EQUAL. HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES" CABINET HARDWARE SCHEDULE: SEMI-EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP-28. (0.028" NOMINAL THICKNESS); EDGES: GP-28 (0.028" NOMINAL GP-50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP-28 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: .3 .2 .1 .3 .2 THICKNESS). .1 THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. 1.10 1.9 .4 .3 .2 AFFECT THE CONTRACT SUM AND CONTRACT TIME. ACCOMMODATE THE SUBSTITUTION. PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 400B FOR ELECTRICAL OR DATA OUTLET LOCATIONS. PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL NEMA LD 3 AND GP-50 (0.050" NOMINAL THICKNESS). COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH 6.6 .2 SURFACES. .1 6.5 ACRYLIC LATEX SATIN ENAMEL FINISH: GYPSUM WALLBOARD: ACRYLIC LATEX SEMI-GLOSS ENAMEL FINISH: 1. A. 10. 2. 1. A. WOOD:8. PRIMER-SEALER. PRIMER: 1 COAT #50801 WONDER TONES LATEX SEMI-GLOSS ENAMEL. FINISH: 2 COATS #83XX MIRROLAC-WB ARCYLIC PRIMER-SEALER. PRIMER: 1 COAT #51701 WONDER-PRIME LATEX 9.2 MECHANICAL AND ELECTRICAL15/16 WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE "X" TAPERED REDUCIBLE ACRYLIC DRY FOG COATING. FINISH: 2 COATS #57601 UNI-GRIP-WB WATER1. ACRYLIC DRY FOG FLAT FINISH: REDUCIBLE ACRYLIC DRY FOG COATING FINISH: 2 COATS #57601 UNI-GRIP-WB WATER ACRYLIC DRY FOG FLAT FINISH: SEMI-GLOSS FINISH FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC LATEX PRIMER. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC ACYRLIC SEMI-GLOSS ENAMEL FINISH: SEMI-GLOSS ENAMEL. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC LATEX PRIMER. A. NON-FERROUS STRUCTURE:4. 1. A. FERROUS STRUCTURE:3. 2. 1. A. NON-FERROUS METAL:2. 2. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC ACRYLIC SEMI-GLOSS ENAMEL FINISH: FOR THE VARIOUS SUBSTRATES, AS INDICATED. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 1. A. FERROUS METAL:1. .1 REINSTALL SUCH ITEMS. 9.10 SURFACE VARIATION OF ¼" IN 10 FEET, NON-CUMULATIVE. HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID 9.7 .1 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN REFLECTED CEILING PLAN SHALL GOVERN. IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL RESILIENT FLOORING:9.6 CASED OPENING UNLESS NOTED OTHERWISE. 9.5 UNLESS NOTED OTHERWISE. .2 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM .1 DAMAGED OR SOILED TILES. 9.4 CRITERIA ESTABLISHED IN GA 214 AS FOLLOWS: COMPLY WITH ASTM C 840 STANDARD SPECIFICATION FOR APPLICATION 3. LEVEL 5 - GYPSUM WALLBOARD ON ALL FINISHED CEILINGS AND ALL COMMON AREA WALLS. LEVEL 4 - GYPSUM WALLBOARD ON INTERIOR WALLS FOR ALL TENANT SPACES. AND FINISHING OF GYPSUM BOARD; GA 214 RECOMMENDED LEVELS OF LEVEL 2 - GYPSUM WALLBOARD BEHIND AN APPLIED WALL COVERING, GYPSUM BOARD FINISH; AND GA 216-2000 APPLICATION AND FINISHING OF GYPSUM BOARD; PROVIDE GYPSUM WALLBOARD MINIMUM FINISH LEVELS MEETING THE 2. AND WALLS AND CEILINGS IN MECHANICAL AND EQUIPMENT ROOMS. LEVEL 1 - GYPSUM WALLBOARD PERMANENTLY CONCEALED FROM VIEW.1. B. DRYWALL FINISHING: 4. A. 15/16.0 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY JUNCTION BOXES ARE NOT PERMITTED. TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE. SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. FLOOR SLAB DOES NOT VARY BY MORE THAN ¼" IN 20'-0" NON- LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED EXISTING CONSTRUCTION AND WALL TYPES. SEE WALL LEGEND FOR SYMBOLS RELATED TO TO BOTTOM OF FINISHED CEILINGS. TO TOP OF FINISHED FLOORS. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. TO FINISHED FACE OF GYPSUM BOARD. DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: PROCEEDING WITH CONSTRUCTION. REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND OBSERVE PRIOR TO ANY COMMENCEMENT OF "ROUGH-IN" LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL PROVIDING PROPER ACCESS TO RECEPTACLES. SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD OUTLETS, UNLESS OTHERWISE NOTED. DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS COORDINATE WITH OTHER CEILING COMPONENTS. SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S AND PLUMBING, SIGNED AND STAMPED FOR BY A CERTIFIED ENGINEER FOR STATE FILING AND BOARD OF HEALTH SUBMITTAL. DESIGN/BUILD DRAWINGS FOR FIRE PROTECTION, MECHANICAL, ELECTRICAL GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF INSTALLATION AND INTER-SYSTEM COORDINATION OF MECHANICAL AND BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTIN AND HVAC) AND CONTRACTOR. GN.10 GN.9 CLOSE-IN OF WALLS. GN.8 GN.7 OBSERVATION. GN.6 WITH CONSTRUCTION. GN.5 OTHERWISE. GN.4 GN.3 D. C. B. A. GN.2 GN.1 GENERAL NOTESGN CONSTRUCTION. 15/16.13 FOR SPECIFIC LOCATION. 15/16.12 15/16.11 WHITE. 15/16.10 15/16.9 INSTALLATION SHALL OCCUR. 15/16.8 15/16.7 EQUIPMENT. 15/16.6 OWNER'S AGENT. 15/16.5 15/16.4 15/16.3 15/16.2 ELECTRICAL SYSTEMS. 15/16.1 WALL CONSTRUCTION, MEP SHELL SPECIFICATIONS: IN ADDITION TO THE NOTES BELOW, THE PREVIOUSLY ISSUED SPECIFICATION FOR DVISIOIN 15 AND 16 SHALL BE APPLICABLE TO ALL WORK UNDER THESE CONTRACT DOCUMENTS. COPIES OF THESE SPECIFICATIONS ARE AVAILABLE FROM THE ARCHITECT (PEDCOR DESIGN GROUP) AND THE GENERAL CONTRACTOR (SIGNATURE CONSTRUCTION). PROVIDE SHOP DRAWINGS FOR OWNER'S APPROVAL PRIOR TO FABRICATION. INTERIOR DOOR FRAMES: PROVIDE HOLLOW METAL FRAME UNLESS NOTED OTHERWISE. FRAMES TO BE PREPPED AND PAINTED IN THE FIELD. COLOR SPECIFIED BY DESIGNER. WHITE BIRCH, PLAIN SLICED. PLY PC-5 PARTICLE BOARD SOLID CORE. WOOD VENEER FACES: INTERIOR DOORS: AWI SECTION 1300 "PREMIUM GRADE" PRE-MACHINED 5-8.2 .1 DOORS TO BE PREPPED AND PAINTED IN THE FIELD. .2 WARRANTY: LIFETIME WARRANTY ON ALL ARCHITECTURAL FLUSH WOOD DOORS, INCLUDING THOSE DOORS WITH VIEW PANELS AND LOUVERS. PROVIDE DRAFT COPY OF WARRANTY WITH SUBMITTALS. GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. REQUIREMENTS FOR HEAT-STRENGTHENED GLASS. GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 9.1 FINISHES9 8.4 AND LOCKSETS. 8.3 DOOR HARDWARE: PROVIDE MEDIUM DUTY WITH ADA LEVER HANDLE LATCH SUITE 113 Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 46 0 3 2 GO D B Y H E A R T H & H O M E Drawn By Checked ByPrint Date Revisions: 08/18/2015 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 20 0 S O U T H R A N G E L I N E R O A D IN D I A N A D E S I G N C E N T E R SU I T E 1 1 3 10/12/15 Construction Set T1.3 LOWER LEVEL LIFE SAFETY PLAN Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 10/12/15 CONSTRUCTION DOCUMENTS 08/18/2015 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP. c COPYRIGHT 2015 JAMES R. STUTZMAN, CARMEL, INDIANA BNR MC 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. L L.7L.6 L.9 MJK.1K K.5G.3 G.4 H H.5 .6 .5 1 F 5 7 G 6 3 2.9 2 8 8.1 A.1 C E 10 4 H.9 11 9.1 9.9 10.9 10.85 7.8 7.3 3.8 3.3 BA.5A A.2 D 9 1'-0" GODBY HEARTH AND HOME SUITE 113 1,466 SQ.FT. ABOVE LOWER LEVEL 00 5 00 8 RAMP DOWN UP UP UP UP N SCALE: 1/16" = 1'-0" 1 LOWER LEVEL LIFE SAFETY PLAN T1.3 SUITE 113 Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 46 0 3 2 GO D B Y H E A R T H & H O M E Drawn By Checked ByPrint Date Revisions: 08/18/2015 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 20 0 S O U T H R A N G E L I N E R O A D IN D I A N A D E S I G N C E N T E R SU I T E 1 1 3 10/12/15 Construction Set T1.4 1ST FLOOR LIFE SAFETY PLAN Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 10/12/15 CONSTRUCTION DOCUMENTS 08/18/2015 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP. c COPYRIGHT 2015 JAMES R. STUTZMAN, CARMEL, INDIANA BNR MC 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. Fir e C a b i n e t L L.7L.6 L.9 MJK.1K K.5G.3 G.4 H H.5 .6 .5 1 F 5 7 G 6 3 2.9 2 8 8.1 A.1 C E 10 4 H.9 11 9.1 9.9 10.9 10.85 7.8 7.3 3.8 3.3 BA.5A A.2 D 9 SCOPE OF WORK 55 ' - 7 " FE E T O F T R A V E L GODBY HEARTH AND HOME SUITE 113 1,466 SQ.FT. EXIT MEN'S RESTROOM WOMEN'S RESTROOM 75CS5EXS75CS5EXS CODE SUMMARY ACCESSORY OCCUPANCY GROUP – Godby Hearth & Home Group M-Mercantile Use Group per IBC 508.3.1 Accessory use is less than 10% first floor area, 1466 sq ft allowable OCCUPANCY SEPARATIONS Occupancy separations not required per IBC 508.3.1.3 One hour, non-load-bearing demising wall provided per UL Design U432 EGRESS REQUIREMENTS One means of egress required per IBC Table 1019.1 One egress path directly outdoors resulting in no impact the existing building egress paths, distances, or width requirements. Total egress width provided: 72 inches Total egress width required per IBC 1005.1: 14.1 in. (minimum 1 door leaf total 36 inches) All exit doors swing in the direction of travel per IBC 1008.1.2 All exit doors are provided with illuminated exit signs per IBC 1011.1 ACCESSIBILITY REQUIREMENTS All existing restrooms are upgraded by the additional of a vertical grab bar in toilet compartments, in compliance with ICC/ANSI A117.1-2003; Section 604.5.1 All other accessibility requirements are currently met by Existing Building. BUILDING AREAS Godby Hearth & Home Tenant Area 1466 square feet Existing Building First Floor Area (including Godby Hearth & Home area)52,092 square feet Existing Building Second Floor Area 51,925 square feet Existing Building Garage Area 52,034 square feet OCCUPANT LOADING Godby Hearth & Home Tenant Area 48 persons Existing Building First Floor Area (excluding Godby Hearth & Home area)1713 persons Existing Building Second Floor Area 520 persons Existing Building Garage Area 261 persons BUILDING CODES General Administrative Rules (675 IAC 12) 2006 Edition Indiana Building Code, 2014 Edition (IBC 2012) 2014 Edition Indiana Building Code - Accessibility (ICC/ANSI A117.1-2009) 2014 Edition Minimum Design Loads (ASCE 7-2010) 2014 Edition Indiana Plumbing Code, 2012 Edition (UPC 1997) 2012 Edition Indiana Electrical Code, 2008 Edition (NFPA 70-2008) 2009 Edition Indiana Mechanical Code, 2014 Edition (IMC 2012) 2014 Edition Indiana Fuel Gas Code, 2014 Edition (IFGC 2012) 2014 Edition NFPA 13-2010 Installation of Sprinkler Systems 2012 Edition NFPA 72-2010 National Fire Alarm Code 2014 Edition EXISTING BUILDING OCCUPANCY GROUPS - Shell & Core Group B – Business and M – Mercantile for first and second floors Group S-2- Parking for lower level EXISTING BUILDING CONSTRUCTION TYPE Type II-B - Non-combustible construction materials; Non-rated EXISTING BUILDING SPRINKLER SYSTEM Fully protected by an automatic sprinkler system per NFPA 13-2010 EXISTING BUILDING APPROVALS Construction Design Release Letter - Foundation – Project Number 323831 Date 02.02.07 Construction Design Release Letter – Arch Str – Project Number 323831 Date 02.16.07 Construction Design Release Letter – MEP – Project Number 323831 Date 02.04.08 ! N SCALE: 1/16" = 1'-0" 1 1ST FLOOR LIFE SAFETY PLAN T1.4 SUITE 113 Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 46 0 3 2 GO D B Y H E A R T H & H O M E Drawn By Checked ByPrint Date Revisions: 08/18/2015 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 20 0 S O U T H R A N G E L I N E R O A D IN D I A N A D E S I G N C E N T E R SU I T E 1 1 3 10/12/15 Construction Set T1.5 2ND FLOOR LIFE SAFETY PLAN Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 10/12/15 CONSTRUCTION DOCUMENTS 08/18/2015 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP. c COPYRIGHT 2015 JAMES R. STUTZMAN, CARMEL, INDIANA BNR MC 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. L L.7L.6 L.9 MJK.1K K.5G.3 G.4 H H.5 .6 .5 1 F 5 7 G 6 3 2.9 2 8 8.1 A.1 C E 10 4 H.9 11 9.1 9.9 10.9 10.85 7.8 7.3 3.8 3.3 BA.5A A.2 D 9 233 231 2 3 5 248 232 228 D 2 7 GODBY HEARTH AND HOME SUITE 113 1,466 SQ.FT. BELOW SECOND LEVEL DN DN DN DN N SCALE: 1/16" = 1'-0" 1 2ND FLOOR LIFE SAFETY PLAN T1.5 SUITE 113 Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 46 0 3 2 GO D B Y H E A R T H & H O M E Drawn By Checked ByPrint Date Revisions: 08/18/2015 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 20 0 S O U T H R A N G E L I N E R O A D IN D I A N A D E S I G N C E N T E R SU I T E 1 1 3 10/12/15 Construction Set A1.1 CONSTRUCTION/ FINISH PLAN Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 10/12/15 CONSTRUCTION DOCUMENTS 08/18/2015 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP. c COPYRIGHT 2015 JAMES R. STUTZMAN, CARMEL, INDIANA BNR MC 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. F 10 ' - 9 7 / 8 " 11'-9" 1'-3 1/4" 10 ' - 9 3 / 4 " 8' - 6 " 11'-3 1/8"5' - 4 " 3' - 2 " 8' - 1 0 5 / 8 " 8' - 1 0 5 / 8 " 8' - 1 0 5 / 8 " 8' - 1 0 5 / 8 " 8' - 1 0 5 / 8 " 3 7 A1.3 8 A1.3 1 A1.4 FP1 FP2 FP3FP4 FP4 FP4 FP4 FP4 FP4 FP4 FP5 FP4 FP4 FP8 FP1 FP7 FP7 FP7 FP7 FP7 FP7 FP7 OFFICE 104 INTERIOR WINDOW DISPLAY 100 EXTERIOR WINDOW DISPLAY 105 COFFEE BAR 102 SHOWROOM 101 SHOWROOM 103 W2 W1 W1 W3 104 ALL NEW WORKSURFACES TO RECEIVE 3" GROMMETS. NEW GROMMET LOCATIONS TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT. GROMMET COLOR TO BE: BLACK RADIUS ALL OUTSIDE CORNERS OF COUNTER TOPS. SIZE OF RADIUS TO BE VERIFIED WITH DESIGNER. 12. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 13. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. 14. REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. ALIGN FINISHED FACE OF WALL. CONSTRUCTION PLAN NOTES: FP1 FP2 FP3 FP4 FP5 FP6 FP7 GENERAL CONSTRUCTION NOTES: DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER. DO NOT SCALE DRAWINGS. 1. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION.3. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. 4. 5.PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. 6.EXISTING DOORS AND DOOR FRAMES TO BE REUSED ARE TO BE CLEANED AND REINSTALLED AT COMPLETION OF CONSTRUCTION. CONTACT DESIGNER TO REVIEW AND APPROVE DOORS THAT ARE QUESTIONABLE FOR REUSE. 7.NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). 8. 9.ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS. 10. 11. EXISTING PARTITION TO REMAIN NEW WALL PARTITION WALL LEGEND: NOTES: SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. ALL WALLS ARE TO BE W3 UNLESS NOTED OTHERWISE. 2. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL UNLESS NOTED OTHERWISE. ALL NEW FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT WALL FINISH AND INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED, A PLAN MUST BE SUBMITTED TO THE ARCHITECT FOR REVIEW FOR AESTHETIC PURPOSES ONLY. SEE A1.3 FOR DOOR SCHEDULE.15. ALL PENETRATIONS IN RATED WALL PARTITIONS AND FLOOR SYSTEMS SHALL BE FIRE RATED ASSEMBLIES. SUBMIT PRODUCT DATA AND ASSEMBLY DRAWINGS WITH TEST FILE NUMBERS FOR REVIEW. 16. INSULATION FOR INTERIOR WALL APPLICATION SHALL BE FORMALDEHYDE-FREE, UNFACED, GLASS-FIBER BLANKET INSULATION IN BATT FORM CONFORMING TO ASTM C 665, TYPE I, WITH THICKNESS TO BE EQUAL OR GREATER THAN THAT STUD THICKNESS OF THE WALL INTO WHICH IS IT INSTALLED. 17. NEW SEMI RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THESE LOCATIONS WITH TOP OF CABINET AT 54" AFF. PAINT TO MATCH ADJACENT WALL SURFACE. CONFIRM QUANTITY OF EXTINGUISHERS WITH FIRE DEPARTMENT. IF EXTINGUISHERS NEED TO BE ADDED VERIFY LOCATIONS WITH THE ARCHITECT. PROVIDE AND INSTALL BLOCKING FOR WALL MOUNTED TELEVISION. TELEVISIONS ARE TO BE MOUNTED AT 5'-0" AFF TO THE BOTTOM. VERIFY IN THE FIELD WITH THE TENANT BEFORE LOCATING BLOCKING AND ELECTRICAL. SEE SECTION 2/A1.4 FOR DETAILS. PROVIDE PLASTIC LAMINATE BASE CABINETS W/ PLASTIC LAMINATE COUNTER TOP. SEE ELEVATIONS FOR DETAILS. PROVIDE PLASTIC LAMINATE WORKSURFACES W/ PLASTIC LAMINATE PEDESTAL STORAGE UNITS AND STORAGE SHELVES. 40 0 NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. DENOTES NEW MILLWORK. DENOTES AREA NOT IN CONTRACT. 4- 7 / 8 " W1 W2 3-5/8" 20 GAUGE METAL STUDS @16"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO 11'-0" ABOVE FINISHED FLOOR. 3-5/8" 25 GAUGE METAL STUDS @16"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE FROM FLOOR TO 4'-0" ABOVE FINISHED FLOOR. INCLUDE DRYWALL FINISHED TOP. 1/2" GLASS STOREFRONT SYSTEM FROM 4'-0" TO BULKHEAD ABOVE. GLASS TO HAVE 3M VINYL FROSTED PATTERN ON INSIDE. 4- 7 / 8 " EXISTING DOOR AND FRAME. SEE BUILDING SHELL PLAN. W3 6" 20 GAUGE METAL STUDS @16"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALL TO EXTEND TO 4'-0" ABOVE FINISHED FLOOR. INCLUDE DRYWALL FINISHED TOP. 7- 1 / 4 " REPAIR AND PATCH ALL FIRE PROOFING ON THE BUILDING SHELL THAT WAS REMOVED DURING CONSTRUCTION. REMOVE FIREPROOFING SPRAY FROM THE DECK AND OTHER ITEMS THAT DO NOT REQUIRE FIRE PROOFING. 18. PROVIDE BLOCKING FOR TENANT'S STORAGE CABINETS. SEE SECTION 2/1.4 FOR DETAILS. FP8 PROVIDE 3/4" THICK MAPLE VENEER PANEL FULL WIDTH AND HEIGHT OF CENTER DISPLAY BAY.NOT USED.W4 2- 1 / 2 " FN1FN1 OFFICE 104 INTERIOR WINDOW DISPLAY 100 EXTERIOR WINDOW DISPLAY 105 COFFEE BAR 102 SHOWROOM 101 SHOWROOM 103 P1 P1 PL2 SC1 SC1 B1 B1 ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. 1. 2. 3. 5. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK TO DESIGNER FOR REVIEW AND APPROVAL BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. NOTE: TENANT IS TO DO ALL OF THE PAINTING. COORDINATE TENANT'S WORK AND PROVIDE TIME IN THE SCHEDULE FOR WORK. NOTE: TENANT IS TO DO THE FLOOR FINISHING. COORDINATE TENANT'S WORK AND PROVIDE TIME IN THE SCHEDULE FOR THE WORK. NOT USED. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. ALTERNATES PAINT MFG: BENJAMIN MOORE COLOR: SUPER WHITE FINISH: EGGSHELL LOCATION: GENERAL NOTE: BY TENANT. P1 PAINT 4. 6. GENERAL FINISH NOTES 1.ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF DESIGNER. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. CONTRACTOR TO VERIFY LEAD TIMES AS SOON AS CONTRACT IS AWARDED AND NOTIFY ARCHITECT IF SPECIFIED FINISHES WILL NOT BE AVAILABLE. DESIGN FEES MAY ACCRUE FOR TIME SPENT TO RESELECT ANY MATERIALS WHICH BECOME UNAVAILABLE DUE TO DELAYS IN ORDERING. FINISH PLAN NOTES: FN1 EXISTING STAINED FLOOR TO REMAIN. VINYL BASE MFG: JOHNSONITE COLOR: 50 WHITE SIZE: 4" COVE LOCATION: GENERAL NOTE: BY TENANT. BASE FLOORCOVERING FINISH LEGEND NOT USED.PL1 PLATIC LAMINATES SEALED CONCRETE COLOR: CLEAR LOCATION: GENERAL NOTE: BY TENANT. PAINT MFG: BENJAMIN MOORE COLOR: SUPER WHITE FINISH: DRY FOG LOCATION: OPEN CEILING NOTE: BY TENANT. P2 PLASTIC LAMINATE MFG: WILSONART COLOR: FUSION MAPLE 7909-60 FINISH: MATTE LOCATION: COFFEE BAR PL2 PAINT MFG: BENJAMIN MOORE COLOR: SUPER WHITE FINISH: FLAT LOCATION: BULKHEADS, CEILING CLOUD NOTE: BY TENANT. P3 B1 SC1 N N SCALE: 1/8" = 1'-0" 1 CONSTRUCTION PLAN A1.1 SCALE: 1/8" = 1'-0" 2 FINISH PLAN A1.1 SUITE 113