E-501.pdf
F VC SC A L E : PE R O N E L I N E D I A G R A M A S I N G L E R A C E W A Y ) (M A Y B E C O M B I N E D I N 2# 1 4 , 3 / 4 " C . TE L E . C A B L E TE L E . OU T L E T ME Z Z . LO B B Y FL O O R IN H O I S T W A Y IN E L E V A T O R EQ U I P M E N T FIR S T LO B B Y FL O O R RO O M #1 8 S H I E L D E D IN D U S T R I A L VA P O R T I T E IN P I T FI X T U R E RE C E P T A C L E GF I PO W E R F E E D , S I Z E D 48 0 V , 3 ∅ E L E V A T O R 2# 1 2 , # 1 2 G . , 3 / 4 " C . MA N U F A C T U R E R / IN S T A L L E R CO N T R O L CA B L I G H T S BY D I V I S I O N 2 6 BY E L E V A T O R TO 4 8 0 V P A N E L PE R P L A N S IN H O I S T W A Y EQ U I P M E N T RO O M IN E L E V A T O R FI R S T FL O O R LO B B Y BY D I V . 1 6 TW I S T E D P A I R ME Z Z A N I N E FL O O R LO B B Y TO 2 0 8 / 1 2 0 V P A N E L DE D I C A T E D C I R C U I T TO 2 0 8 / 1 2 0 V P A N E L DE D I C A T E D C I R C U I T IN E L E V A T O R RE C E P T A C L E GF I 2# 1 2 , # 1 2 G . , 3 / 4 " C . TO 2 0 8 / 1 2 0 V P A N E L DE D I C A T E D C I R C U I T TO 4 8 0 / 2 7 7 V P A N E L DE D I C A T E D C I R C U I T MA C H I N E R O O M LI G H T F I X T U R E S IN R O O M 2# 1 4 , 3/4 " C . 48 0 V 3 P C I R C U I T BR E A K E R , W I T H AU X I L I A R Y N . O . C O N T A C T IN E L E V A T O R M A C H I N E RO O M 20 A / 2 P CIR C U I T B R E A K E R IN E L E V A T O R M A C H I N E R O O M 2# 1 0 , # 1 0 G . , 3 / 4 " C . TO 2 0 8 / 1 2 0 V P A N E L PE R P L A N S NO T T O S C A L E FA C P ZA M Z A M ZA M S S S S CA R D A C C E S S D O O R W I R I N G D E T A I L 0" 1" "A N S I " C O N C E A L E D D O O R PO S I T I O N S W I T C H A S SC H E D U L E D B Y D I V I S I O N 8 ON E 3 / 4 " C O N D U I T B Y DI V I S I O N 2 6 F O R E L E C T R I C PO W E R T R A N S F E R , EL E C T R I F I E D H I N G E , EL E C T R I C L A T C H B O L T , O R EL E C T R I C S T R I K E . S E E D O O R SC H E D U L E . CA R D A C C E S S B O X A N D CO N D U I T B Y D I V I S I O N 2 6 FL O O R L I N E HO M E R U N T O SY S T E M CO N T R O L L E R JU N C T I O N B O X FO R P O W E R DO O R C O N T R O L L E R IN T E R F A C E NE W D O O R S : O N E 3/ 4 " C O N D U I T E A C H S I D E BY D I V I S I O N 2 6 CE I L I N G ON E 3 / 4 " C O N D U I T B Y DI V I S I O N 2 6 F O R EL E C T R I C P O W E R TR A N S F E R , E L E C T R I F I E D HI N G E , E L E C T R I C LA T C H B O L T , O R EL E C T R I C S T R I K E . S E E DO O R S C H E D U L E . 96" 96" 48" 48" 72" 48" 36" 20" 20" 20" NOTE 2 20" 20" 96"96"72"96"48"20"48"48"84" EL E C T R I C A L E L E V A T I O N FI X T U R E S W I T C H I N G D E T A I L TY P I C A L D U A L B A L L A S T E D L I G H T TY P I C A L M C C A B L E I N S T A L L A T I O N DE T A I L F O R W I R I N G D E V I C E S GENERAL NOTES - APPLY TO ALL ELECTRICAL SHEETS: EL E C T R I C A L R O U G H - I N A T D O O R F R A M E CONDUIT STUB UP DETAIL TY P I C A L G R O U N D I N G D E T A I L W EX I T P R R WC L D 4 K M a 2 P PT 3 a b NO T T O S C A L E NO T E S : 1. E Q U I P M E N T M O U N T I N G H E I G H T S S H A L L B E I N D I C A T E D U N L E S S O T H E R W I S E N O T E D O N T H E D R A W I N G S O R I N T H E S P E C I F I C A T I O N S . 2. C O N C E A L R E C E P T A C L E B E H I N D W A T E R C O O L E R . V E R I F Y E X A C T M O U N T I N G H E I G H T S . SY M B O L S : FL O O R CE I L I N G NE U T R A L "b " S W I T C H L E G ( E M E R G E N C Y ) "a " S W I T C H L E G LAMP LAMP 2-LAMP BALLAST 1-LAMP BALLAST LAMP NO T T O S C A L E JU N C T I O N B O X A B O V E C E I L I N G ( T Y P I C A L ) WI R I N G D E V I C E ( T Y P I C A L ) MC C A B L E MC C A B L E EM T T O C O R R I D O R EM T 11.10. 9. 7. 6. 5. 4. 3. 2. 1.VERIFY ALL DIMENSIONS FROM ARCHITECTURAL PLANS.DIMENSIONS SHOWN ON OUTLET BOXES SHALL BE FROM THE FINISHED FLOOR TO THE TOP OF THE BOX - SEE ELEVATION DETAIL THIS SHEET.CONDUIT TO LIGHTS IS SHOWN TO INDICATE SWITCHING AND DOES NOT INDICATE QUANTITY OR EXACT LOCATION. OTHER CONDUIT SHOWN INDICATES CONNECTION, BUT DOES NOT INDICATE QUANTITY OR LOCATION.SUPPORT FLUORESCENT FIXTURES FROM STRUCTURE ABOVE - SEE DETAIL ON SHEET E-502.VERIFY LOCATION OF LIGHTS IN ROOMS CONTAINING EXPOSED DUCTWORK AND PIPING BY OTHER TRADES AND RELOCATE, IF NECESSARY, AS REQUESTED BY THE ARCHITECT.VERIFY LOCATION OF MOTOR STARTERS, DISCONNECTS, PANELBOARDS, ETC., IN ROOMS CONTAINING EXPOSED DUCTWORK AND PIPING BY OTHER TRADES AND RELOCATE TO AN ADJACENT, UNOBSTRUCTED AREA AS REQUESTED BY ARCHITECT.VERIFY HEIGHT AND LOCATION OF OUTLETS BEHIND WATER COOLERS WITH OTHER TRADES SO THAT OUTLETS ARE CONCEALED.SEE MECHANICAL PLANS FOR EXHAUST FAN SCHEDULE AND LOCATIONS.VERIFY EXACT LOCATION OF ALL OUTLETS IN LABORATORY EQUIPMENT AND BUILT-IN/CASEWORK FURNITURE WITH EQUIPMENT SUPPLIERS ROUGH-IN DRAWINGS BEFORE ROUGHING IN.MULTI-SWITCHED LIGHT FIXTURES SHALL HAVE THE OUTSIDE LAMPS CONTROLLED BY THE SWITCH(ES) CLOSEST TO THE DOOR OPENING AND THE MIDDLE LAMP(S) CONTROLLED BY THE OTHER SWITCH(ES).TERMINATE ALL COMMUNICATIONS/TECHNOLOGY SYSTEM CONDUIT STUBS WITH A BUSHING.11.10. 9. 8. 7. 6. 5. 4. 3. 2. 1. SC A L E : N O N E CA B L E T Y P E L E G E N D ( C A B L E B Y D I V I S O N 2 6 ) 18 - G A U G E , 2 - C O N D U C T O R 18 - G A U G E , 4 - C O N D U C T O R 18 - G A U G E , 6 - C O N D U C T O R , O V E R A L L S H I E L D 18 - G A U G E , 2 - C O N D U C T O R , O V E R A L L S H I E L D ( 4 8 5 C A B L E ) DO O R S T R I K E L O C A T I O N . LO C A T E A N C H O R TO P R O V I D E CL E A R D I M E N S I O N AB O V E C O N D U I T . CO N D U I T T O TE R M I N A T E I N CA V I T Y S P A C E BE T W E E N W A L L FR A M I N G A N D DO O R F R A M E . DO U B L E S T U D F R A M I N G (T Y P I C A L E A C H S I D E O F D O O R FR A M E ) . FR A M E A N C H O R P R O V I D E D WI T H D O O R F R A M E ( T Y P I C A L OF 3 P E R S I D E ) . ST R I K E E N C L O S U R E PR O V I D E D W I T H D O O R F R A M E . TW O - G A N G O U T L E T B O X (F A C I N G L O C K E D S I D E O F DO O R ) F O R C A R D R E A D E R . 3/ 4 " E M T I N S T A L L E D T H R O U G H WA L L F R O M E N C L O S U R E AB O V E C E I L I N G T O L O W E R CA B L E T R A Y I N N E A R E S T CO R R I D O R . 1/ 2 " E M T I N S T A L L E D I N W A L L CA V I T Y F R O M E N C L O S U R E AB O V E C E I L I N G D O W N T O SP A C E B E T W E E N F R A M E AN C H O R A N D T O P O F S T R I K E BO X . C O N D U I T P A S S E S TH R O U G H D O U B L E S T U D S . PR O V I D E B U S H I N G AR L I N G T O N I N D U S T R I E S # E M T SE R I E S P R E S S F I T NO N M E T A L I C B U S H I N G A T LO W E R E N D . 3/ 4 " E M T I N S T A L L E D I N W A L L CA V I T Y F R O M E N C L O S U R E AB O V E C E I L I N G D O W N T O B O X FO R R E A D E R . 8" X 6 " X 4 " N E M A - 1 S T E E L EN C L O S U R E W I T H P A I N T E D FI N I S H A N D S C R E W H E L D CO V E R ; H O F F M A N #A - S E 8 X 6 X 4 , O R E Q U A L . IN S T A L L E N C L O S U R E 1 2 " AB O V E A C C E S S I B L E C E I L I N G AN D S E C U R E T O W A L L FR A M I N G . NO T T O S C A L E FINISHED FLOORTHREADEDPLUGTHREADEDCOUPLING CONDUIT NOT TO SCALE= STUB UP SYMBOL CU G R D . B A R RA C K S #6 A W G I N S U L A T E D GR O U N D C O N D U C T O R MD F & I D F ' S G MA I N E Q U I P M E N T B O N D I N G JU M P E R ( S I Z E I N A C C O R D A N C E WI T H N E C A R T I C L E 2 5 0 ) TO MAIN SERVICE EQUIPMENT SWITCHBOARD OR PANELBOARD GROUND BUS AT SERVICE ENTRANCE N G PANELBOARDGDISTRIBUTION PANELBOARDN N G PA N E L B O A R D EQUIPMENT GROUND -SIZE AS SHOWN ON DRAWINGS TR A N S F O R M E R C N B A B O N D I N G J U M P E R S (S I Z E I N ACCORDANCE WITH NEC ARTICLE 250) N G COMMUNICATIONS SYSTEMS EQUIPMENT CABINET GROUND COMMUNICATIONS PLYWOOD BACKBOARD GROUND BAR TELEPHONE SERVICE DEMARK GROUND BAR 3/4"X10' CU GROUND ROD AS REQUIRED (SEE SECTION 260526) #3 / 0 C U B O N D I N G JU M P E R I F N O T FA C T O R Y I N S T A L L E D EQ U I P M E N T G R O U N D . SI Z E A S S H O W N O N DR A W I N G S EQ U I P M E N T GR O U N D - SI Z E A S SH O W N O N DR A W I N G S G NE U T R A L B U S GR O U N D B U S BU I L D I N G S T E E L (I N D O O R ) O R GR O U N D R O D (O U T D O O R ) GE N E R A T O R F R A M E AN D E N C L O S U R E N C GE N E R A T O R B A #3 / 0 B A R E C U G R O U N D I N G EL E C T R O D E C O N D U C T O R #3 / 0 C U E Q U I P M E N T BO N D I N G J U M P E R BO N D I N G B U S H I N G ( T Y P I C A L ) SE R V I C E E Q U I P M E N T E N C L O S U R E (M A I N S W I T C H B O A R D ) MA I N B O N D I N G J U M P E R (S I Z E I N A C C O R D A N C E WI T H N E C A R T I C L E 2 5 0 ) PA N E L B O A R D AU T O M A T I C T R A N S F E R SW I T C H E N C L O S U R E NO T T O S C A L E BUILDING STEEL OR INTERIOR METAL WATER PIPE AND GROUND ROD IF STEEL IS NOT AVAILABLE#3/0 BARE CU GROUNDING ELECTRODE CONDUCTOR 3/ 4 " X 1 0 ' C U GR O U N D R O D BU I L D I N G FO U N D A T I O N RE B A R #3 / 0 B A R E C U GR O U N D R I N G IN C O M I N G ME T A L WA T E R SE R V I C E BU I L D I N G ST E E L #3 / 0 B A R E C U G R O U N D I N G EL E C T R O D E C O N D U C T O R 3/ 4 " X 1 0 ' C U G R O U N D R O D 3/ 4 " X 1 0 ' C U G R O U N D R O D IN C O M I N G S E R V I C E ME T A L C O N D U I T S TR A N S F O R M E R EN C L O S U R E #3 / 0 B A R E C U G R O U N D I N G EL E C T R O D E C O N D U C T O R 12. 12 " X 2 " X 1 / 4 " C O P P E R GR O U N D B U S B A R BU S B A R S T A N D - O F F (T Y P I C A L ) 12 " X 4 " X 1 / 4 " C O P P E R GR O U N D B U S B A R BU S B A R S T A N D - O F F (T Y P I C A L ) 8 7 9 SF N TE L E C O M M U N I C A T I O N S DIS T R I B U T I O N FR A M E G R O U N D I N G B U S B A R ( T G B ) DE T A I L TE L E C O M M U N I C A T I O N S S E R V I C E EN T R A N C E P O I N T M A I N G R O U N D I N G BU S B A R ( T M G B ) D E T A I L TY P I C A L E L E V A T O R W I R I N G D I A G R A M SC A L E : N O N E SC A L E : N O N E NO T E S : CA B CA B HV A C NO N E NO T E S : 1. P R O V I D E E N G R A V E D P H O E N E L I C N A M E P L A T E O N D I S C O N N E C TS S T A T I N G M O R E T H A N O N E S O U R C E S E R V E S T H E EL E V A T O R C A B I N E T . 2. S H O U L D T H E G E N E R A L C O N T R A C T O R U T I L I Z E A N E L E V A T O R M A N U F A C T U R E R T H A T R E Q U I R E M O R E E L E C T R I C A L W O R K TH A N S H O W N O N T H I S D E T A I L , T H E C O S T S S H A L L B E T H E R ES P O N S I B I L I T Y O F T H E G E N E R A L C O N T R A C T O R . 3. E Q U I P M E N T S H O W N S H A D E D I S B Y E L E V A T O R M A N U F A C T U R E R. I T E M S S H O W N D A R K A R E B Y D I V I S I O N 2 6 . C A B C D B B D 140029229 Delegates Row, Suite 150 Indianapolis, IN 46240 317.706.2075 www.enverityENG.com Project:Developer:Sheet Number:Engineer:By:Sheet Title:COPYRIGHT & OWNERSHIP OF DOCUMENTS Enverity Number:Last Revision Date:Set Issue Date Drawn ByChecked BySheet Issue DatePedcor Square Building 5 357 CITY CENTER DRIVE Carmel,IN,46032PLAN NORTH THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana.Construction Documents PCBMW E-501Electrical Details12/18/1512/18/15