HomeMy WebLinkAboutADDENDUM 1 ARCH Pedcor Building 5.pdf ADDENDUM Pedcor Building 5.ADD.001 PROJECT PEDCOR BUILDING 5 385 City Center Drive Carmel, Indiana 46032 ADDENDUM NUMBER Pedcor Building 5.ADD.001 ISSUE DATE 01.22.16 ADDENDUM OUTLINE This Addendum lists changes resulting from the Quality Control Review from 01.04.16 to 01.22.16 ITEM 001.1 Drawing Sheet G103 • WALL TYPES-FIRE RATINGS legend – add new wall type designation for SMOKE RATED BARRIER. • Detail 3/A509 – add note “VESTIBULE/LOBBY IS A SMOKE ENCLOSURE PER SECTION 1022.10”. ITEM 001.2 Drawing Sheets A090, A100B, A101, A110B, A201, A202, A203, A204, A301, A302, A303, A304, A309, A404, A405, A415, A416, A503, A504, A508 • At North end of building, delete exterior porch, ramp, ramp walls and piers, guardrails, handrails, pavers, and stairs. (the north exterior porch, ramp, and entry stairs will no longer be a part of the project scope.) The above drawings will be affected. • Detail 1/A302, remove north porch, stairs, and piers. Ref. B4/A503 for revised detail. Change floor assembly with lowered composite slab. • Detail 2,3/A302, remove north porch, stairs, and piers. Ref. C4/A503 for revised detail. Change floor assembly with lowered composite slab. • Detail 1/A302, remove north porch, stairs, and piers. Ref. D4/A503 for revised detail. Change floor assembly with lowered composite slab. • Detail 2,3/A303, remove north porch, stairs, and piers. Ref. E4/A503 for revised detail. • Detail 1/A304, remove brick pier and 4” conc. Ramp and note reading “ 4” CONCRETE RAMP, SEE RAMP SECTIONS AND DETAILS”. • Detail 4/A309, remove north porch, stairs, and piers. • Delete sht. A404 & A405 from Documents. (these sheets are no longer a part of the project scope.) • Detail B4, C4, D4, E4 on sht. A503 - revise detail, remove north porch, stairs, and piers. see attached sketch AD.001.1 see attached sketch AD.001.2 see attached sketch AD.001.3 see attached sketch AD.001.4 see attached sketch AD.001.54 ITEM 001.3 Drawing Sheet A090 • At the Plaza, delete notes, “BASE BID LINE” located east of the east exterior building wall. • Delete, “ALTERNATE BID LINE”, located to the north of the Plaza. ITEM 001.4 Drawing Sheet A091 • Detail 1/A091, add elevation ref F5/A091 at south wall of plaza, Revise elevation mark at North Plaza Wall to read E4/A091, Revise two section marks where Plaza meets Building to read A3/A092. Add to the end of note “24”X24” PAVER SYSTEM W/ ADJUSTABLE PEDESTALS” the following “OVER SBS MODIFIED BITUMINOUS SHEET PLAZA WATERPROOFING”. • Detail E3/A091, add new dimensions. see attached sketch AD.001.5 • For all Plaza wall details, add the note “GROUT CAVITY SOLID W/ NON EXPANSIVE, NON-SHRINK GROUT”. • Details E1, E2, F2, F3, on sht. A091, remove note “COPPER THRU- WALL FLASHING”, and remove the flashing shown graphically. • Details E1, E2, F2, F3, on sht. A091, add note “SECURE GUARD RAIL NOT LESS THAN 6” INTO GROUT FILLED CAVITY”. • Detail E2/A091, add dimension from top of pavers to top of guard rail to be (3’-6”). Revise dimension 1’-10 9/16” to be (2’-4 13/16”). • Detail F5/A091 to become detail E4/A091. add new detail reference F1/A509 for guard rail. Revise dimension 8’-1 ¾” to be (8’-1 5/8” V.I.F.) and revise dimension 8’-11 ½” to be (9’-4 ½” V.I.F.). See sht. A509. • Detail F5/A091 - New South Plaza Wall Elevation. see attached sketch AD.001.6 ITEM 001.5 Drawing Sheet A092 • New PVC Downspout Boot Detail, B1, sht. A092. see attached sketch AD.001.7 • For all Plaza wall details, add the note “GROUT CAVITY SOLID W/ NON EXPANSIVE, NON-SHRINK GROUT”. • Change the title number for the far right detail B3 to A3 on sht. 092 • Revise plaza wall detail C4, E2, sht. A092. see attached sketch AD.001.8 see attached sketch AD.001.9 • Revise stair detail D3, sht. A092. see attached sketch AD.001.10 • Revise stair detail D4, sht. A092. see attached sketch AD.001.11 • New stair detail E3, sht. A092. see attached sketch AD.001.12 • New stair detail E4, sht. A092. see attached sketch AD.001.13 ITEM 001.6 Drawing Sheet A100A • Parking Level Plan Notes – revise part of note 31 “ALLOW FOR THE NEW 48” to “ALLOW FOR THE NEW 42”. ITEM 001.7 Drawing Sheet A100B • Flip door DU005 going into MEP room U005. Swing door out to Elev. Lobby. • Add text to plan note 1 to read “NOTE: CONNECT NEW TRENCH DRAIN TO EXISTING FOUNDATION TILE BELOW WITH 6” PIPE”. ITEM 001.8 Drawing Sheets A100C and A100D – new sheets • add new sheet A100C see attached full size sht. A100C • add new sheet A100D see attached full size sht. A100D ITEM 001.9 Drawing Sheets A101, 102 • Change Plan Note 20 from “DOWNSPOUTS” to read “DOWNSPOUTS, REF. DETAIL B1/A092 FOR PVC DOWNSPOUT BOOT DETAIL AT PLAZA” sht A101. • Revise dimensions for location of window located on east wall at north stair closest to south landing” sht A101 and A102. ITEM 001.10 Drawing Sheet A107 • Revise brick at detail A1 see attached sketch AD.001.14 • Revise brick at detail A2 see attached sketch AD.001.15 • Revise brick at detail A3 see attached sketch AD.001.16 • Delete detail B4 from sheet, add text “NOT USED”. • Detail D5 – change text 4” CMU BACK-UP, to read, 5/8” EXT. SHEATHING OVER 2X4 WD. STUD BACK-UP, BLOCKING FOR 2X4 AS REQ’D”. ITEM 001.11 Drawing Sheets A201-A206 • Under “ELEVATION NOTES”, Add note 2 to read “BRICK LEDGE ELEVATIONS ARE TO BE GIVEN DURING CONSTRUCTION”. • Elevation 1/A201 – replace text “PLASTIC MOLDED LOUVER W/ EIFS TRIM SURROUND” with the text “L4: PAINTED WOOD LOUVER W/ EIFS TRIM SURROUND, REF. B4/A603” • Elevation 2/A201 – replace text “PLASTIC MOLDED LOUVER W/ DECORATIVE TRIM AND KEYSTONES” with the text “L1: PAINTED WOOD LOUVER W/ DECORATIVE TRIM AND KEYSTONES,, REF. B4/A603” • Elevation 1/A202 – replace text “PLASTIC MOLDED LOUVER W/ BRICK ROWLOCK SURROUND” with the text “L5: PAINTED WOOD LOUVER REF. B4/A603, W/ BRICK ROWLOCK SURROUND, B1”. • Elevation 2/A202 – replace text “PLASTIC MOLDED LOUVER W/ DECORATIVE TRIM AND KEYSTONES” with the text “L1: PAINTED WOOD LOUVER W/ DECORATIVE TRIM AND KEYSTONES,, REF. B4/A603” ITEM 001.12 Drawing Sheets A201, A202, A203, A205, A206, A302, A603 • Details 1/A201, 2/A201, 1/A202, 2/A202, F1/A203, F1/A205, C2/A206, 2/A302, B4/A603 - Replace portion of note with the text “PLASTIC MOLDED LOUVER” or “ROUND FIXED LOUVER” with the text “PAINTED WOOD LOUVER”. ITEM 001.13 Drawing Sheet A302-A309 • Replace wall section note at second floor that reads “1 ½” LT. WT. AGG. CONC. TOPPING ON KRAFT PAPER OVER T&G SUBFLOOR TRUSSES” with the note “1 ½” CONCRETE TOPPING OVER T&G SUBFLOOR ON WOOD FLOOR TRUSSES”. ITEM 001.14 Drawing Sheets A302, A503, A504 • Detail 1,2,3 on sht. A302, B2/A503, B1/A504 - Add new dimension for gable cornice from face of stud to outside face of 2x to read 1’-0 3/8”. • Detail 1/A302 – revise entry and revise note at second floor to read “1 ½” CONCRETE TOPPING OVER T&G SUBFLOOR ON WOOD FLOOR TRUSSES”. Change floor assembly with lowered composite slab. see attached sketch AD.001.17 • Detail 2/A302 – revise entry and revise note at second floor to read “1 ½” CONCRETE TOPPING OVER T&G SUBFLOOR ON WOOD FLOOR TRUSSES”. Change floor assembly with lowered composite slab. see attached sketch AD.001.18 • Add new detail 5/A302 (SECTION DETAIL), see attached sketch AD.001.19 • Add new detail 6/A302 (SECTION DETAIL), see attached sketch AD.001.20 ITEM 001.15 Drawing Sheet A304 • Detail 3/A304 – replace text “ALUMINUM CLAD WOOD DOOR, REF. DOOR SCHEDULE”, with the text “ALUM. CLAD WOOD WINDOW, REF. WINDOW SCHEDULE” for both first and second floors. ITEM 001.16 Drawing Sheets A307, A505 • Detail 2, 3 on sht. A307, B1/A505 - Add new dimension for gable cornice from face of stud to outside face of 2x to read 1’-8 9/16”. ITEM 001.17 Drawing Sheet A309 • Details 3, 4 on sht. A309 – Change note “(1) LAYER 5/8” GYP. TYPE C, AND RESILENT FURRING CHANNELS ON BOTTOM OF TRUSSES” to “SUSPENDED 5/8” GYP. BD. CEILING”. ITEM 001.18 Drawing Sheets A401, A402 • Details B2, C2, E2, F2, on sht. A401 and E1, F1, on sht. A402 - Add new note “NER 258, 2HOUR SYSTEM ‘G’ CEILING ASSEMBLY”. Note – this is note the suspended ceiling that is shown. • Sht. A401 – Add 5/8” gyp. Bd. Over 1 5/8” furring channel on east, west, and south walls. Start at Lower Lever parking and continue up to 6” above second floor ceiling. On North Wall, add 5/8” gyp. Bd. Over 3 5/8” mtl. Stud framing. Hold face of gyp. Bd. Off stair stringer ½” to the north. Fur out around windows on north and east sides. Return gyp. Bd. Back to window frame. At Lower and Upper Levels on the west wall of stair, remove conc. Planks and topping to align with edge of stl. Beam flange. • Details B2, C2 on sht. A401 – add new 5/8” gyp. Bd. Over 1 5/8” mtl. Furring at west wall of north stair. Remove areas of precast plank and conc. Slab back to edge of stl. Flange on beam. see attached sketch AD.001.21 see attached sketch AD.001.22 • Details C1/A401 – add detail reference mark B2/A401 on west wall. • Details E1/A401 – add detail reference mark C2/A401 on west wall. • Details E1, F1 on sht. A401 – add and revise dimensions which locate stairs/stringers. see attached sketch AD.001.23 see attached sketch AD.001.24 • All details on sht. A401 – Remove guardrail by north exterior wall on all landings. ITEM 001.19 Drawing Sheet A403 • Detail B1/A403 – Revise and add new dimensions and move elevator door to the east. see attached sketch AD.001.25 • Detail B2/A403 – Revise and add new dimensions and move elevator door to the east. see attached sketch AD.001.26 • Detail B3/A403 – add elevator door on north side of shaft. Revise and add new dimensions and move elevator doors to the east. see attached sketch AD.001.27 • Detail B4/A403 – Revise and add new dimensions and move elevator door to the east. see attached sketch AD.001.28 • Detail C2/A403 – revise section at first floor. Show elevator door on north side lowered by 18”. see attached sketch AD.001.29 ITEM 001.20 Drawing Sheet A406 • Detail C4/A406 – add text “NOTE: FOR REFERENCE TO REINFORCING, USE SHT. S406”. • Detail D1/A406 – revise detail reference that says “used 7” to read “F4/A406”. • Detail D1/A406 – add dimension to locate steps in masonry and concrete walls and add target elevations for top of masonry. see attached sketch AD.001.30 ITEM 001.21 Drawing Sheet A411 • Add new Detail B5/A411 - “ENTRY STAIR RAIL”. see attached sketch AD.001.31 • Detail D4/A411 – shorten both shelves at west wall form 4’ to 3’ to accommodate riser at north wall. see attached sketch AD.001.32 ITEM 001.22 Drawing Sheet A412 • Add new note FN6 under Finish Plan Notes which states “PROVIDE STAIR NOSING TO BE: SCHLUSTER, TREP-HB12S”. • Revise finish reference on first floor at entry. see attached sketch AD.001.33 ITEM 001.23 Drawing Sheets A414-A417 • Add note to read “SEE SHT. A418 FOR SCHEDULE”. Shts. A-414- A417. • Plan F1/A414, F1/A415, F1/A416, F1/A417 - Revise signage referene numbers on plan. see attached sketch AD.001.34 see attached sketch AD.001.35 see attached sketch AD.001.36 see attached sketch AD.001.37 ITEM 001.24 Drawing Sheet A418 • Revise Stair Identification on schedule, sht. A418 see attached full size sht. A418 • Revise signage details 1-5, sht. A418 see attached full size sht. A418 ITEM 001.25 Drawing Sheet A502 • Delete detail C3, D3 from sht. A502. Add text “NOT USED”. ITEM 001.26 Drawing Sheet A504 • Detail E4/A504 – add new text “NOTE: CONNECT NEW TRENCH DRAIN TO EXISTING FOUNDATION TILE BELOW WITH 6” PIPE”. ITEM 001.27 Drawing Sheet A506 • Show 5/8” ext. sheathing graphically and add text “ 5/8” EXTERIOR SHEATHING” to detail A3, B2, B4, sht. A506 see attached sketch AD.001.38 see attached sketch AD.001.39 see attached sketch AD.001.40 ITEM 001.28 Drawing Sheet A508 • Detail E2/A508 – extend center limestone sections down 18”. see attached sketch AD.001.41 • Detail E4/A508 – add elevation reference markers for side views of limestone columns. see attached sketch AD.001.42 • Add new detail F4/A508 (LIMESTONE COLUMNS – SIDE VIEWS), see attached sketch AD.001.43 ITEM 001.29 Drawing Sheets A509 • Detail FA3, sht. A509, add new detail reference A3/A509 for railing elevation. See sht. A509 • Add new detail A3/A509 (RAILING ELEVATION), see attached sketch AD.001.44 • Add new detail B3/A509 (RAILING ELEVATION), see attached sketch AD.001.45 • Detail C4,C5/A509 – replace text “4” CMU BACK-UP” with the text “5/8” EXT. SHEATHING OVER 2X4 WD. STUD BACK-UP, BLOCKING AS REQ’D FOR 2X4”, REF. C4,C5/A509 • Delete detail D1 from sht. A509. Add text “NOT USED”. • Add new detail F3/A509 (RAILING ELEVATIONS), see attached sketch AD.001.46 • Revise guard rails for detail F1/A509, see attached sketch AD.001.47 ITEM 001.30 Drawing Sheet A601 • Revise door schedule – change door type on door number D101C from C to E, add note for door D101C that reads “3’-0” LEAF AND 1’-8” LEAF”. • Add note “EXIST. DOOR” to doors DL002, DL004, DL005, U002, U004 • Door D102 –Update hardware set from “06”. hardware set: Hardware Group No. 06 For use on mark/door #(s) D102 Provide each SGL door(S) with the following: Qty Description Catalog Number Finish Mfr 3 EA HW Hinge 5BB1HW 4.5X4.5 NRP 652 IVE 1 EA Power Transfer EPT10 CON 689 VON 1 EA Elec Exit Device 98-L-F-E996-06-FS- 626 VON SNB-CON 1 EA Rim Housing C953 BDC 626 FAL 1 EA SFIC Core C607 626 FAL 1 EA Surface Closer 1461 (REG/PA 689 LCN AS REQ’D) 1 EA Kick Plate 8400 8”X2” LDW B4E 630 IVE CS 1 EA Wall Stop WS406/407CVX 630 IVE 1 EA Gasketing 488S-BR S-Br ZER 1 EA Access Reader WORK BY SECTION 28 B/O 1 EA Power Supply PS902 LGR VON 1 EA Wire Harness CON-6W VON 1 EA Wire Harness CON-XXP VON • Door D101C –Update hardware set from “15”. hardware set: Hardware Group No. 15 For use on mark/door #(s) D101C Provide each SGL door(S) with the following: Qty Description Catalog Number Finish Mfr 6 EA HW Hinge 5BB1HW 4.5X4.5 NRP 652 IVE 1 EA Power Transfer EPT10 CON 689 VON 1 EA Auto Flush Bolt FB41P 630 IVE 1 EA Dust Proof DP2 626 IVE Strike 1 EA Elec Exit Device QEL+9875-L- 626 VON NL-06-CON 1 EA Rim Housing C953 BDC 626 FAL 1 EA SFIC Core C607 626 FAL 1 EA Coordinator COR X FL 628 IVE 2 EA Mounting MB 689 IVE Bracket 2 EA Surface Closer 1461 (REG/PA 689 LCN AS REQ’D) 2 EA Kick Plate 8400 8”X1” LDW 630 IVE B-CS 2 EA Wall Stop WS406/407CVX 630 IVE 1 EA Gasketing 488S-BR S-Br ZER 2 EA Astragal 328AA AA ZER 1 EA Access Reader WORK BY SECTION B/O 28 1 EA Plwer Supply PS902 900-2RS LGR VON 1 EA Wire Harness CON-6W VON 1 EA Wire Harness CON-XXP VON • Door U005 – add note “EXIST. DOOR TO REMAIN– FLIP DOOR TO SWING OUT”. Change hardware set from “20” to “22”. Add the following hardware set: Hardware Group No. 22 For use on mark/door #(s) Provide each SGL door(S) with the following: Qty Description Catalog Number Finish Mfr 1 EA Fire Exit HW 98-L-NL-F-06 626 VON 1 EA Rim Housing C953 BDC 626 FAL Balance of HW Exist. • For door DL006, revise text from “NEW 4’ WIDE DOOR NEEDED” to “NEW 3’-6” WIDE DOOR NEEDED”. • Detail C5/A601, revise door and frame elevation E & K, see attached sketch AD.001.48 ITEM 001.31 Drawing Sheet A603 • Revise window elevation W3 on sht. A603, see attached sketch AD.001.49 • Add new louver details L4, L5 sht. A603, see attached sketch AD.001.50 • Details E1, E2, F4 on sht. A603 – add new notes “5/8” GYP. BD.” And “1 5/8” MTL. FURRING”. Show graphically on sht. A603., see attached sketch AD.001.51 see attached sketch AD.001.52 see attached sketch AD.001.53 ITEM 001.32 Specification 03 54 13 • Revise paragraph 2.1 A. to state: A. Underlayment: Gypsum-cement-based, self-leveling product that can be applied in minimum uniform thickness of 1/8 inch and that can be feathered at edges to match adjacent floor elevations. 1. Products: Subject to compliance with requirements, provide the following: a. Maxxon Corporation; Commercial Topping. 2. Cement Binder: Gypsum or blended gypsum cement as defined by ASTM C 219. 3. Compressive Strength: Not less than 4000 psi at 28 days when tested according to ASTM C 109. 4. Density 125 pounds per cubic foot (2,000 kg/m3) 5. Underlayment Additive: Resilient-emulsion product of underlayment manufacturer, formulated for use with underlayment when applied to substrate and conditions indicated. • Add to paragraph 2.1 item F as follows: F. Maxxon Reinforcement (MR), Crack Suppression Mat (CSM), or metal lathe 1. Install over subfloor in all areas set to receive Commercial Topping according to manufacturer’s specifications. • Revise paragraph 3.4 by replacing the words “Gyp-Crete 2000/3.2K” and “Gyp-Crete” with the words ” Commercial Topping”. ITEM 001.33 Addendum by Engineers • See Civil Addendum and related replacement sheets C101, C201, C301 and C401. • See Electrical Addendum, sketches and related replacement sheet E801. • See Structural replacement sheets S102, S201, S406, S407 and S408 DISTRIBUTION S. Warne, J. Springer Signature Construction email J. Stutzman, S. Sturtz, Pedcor Design Group email ARCHITECT James A. Walls, AIA CSI Senior Project Architect