Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M-601 - Mechanica Details and Schedules.pdf
AB 0.502.252.75 1.002.503.50 1.502.754.25 2.003.005.00 2.503.255.75 3.003.506.50 3.503.757.25 4.004.008.00 4.504.258.75 5.004.509.50 5.504.7510.25 6.005.0011.00 6.505.2511.75 7.005.5012.50 7.505.7513.25 8.006.0014.00 8.506.2514.75 9.006.5015.50 9.506.7516.25 10.007.0017.00 STATIC PRESSURE AT DRAIN NEGATIVE PRESSURE (IN OF WATER) DRAIN PAN TRAP SIZING SCALE: NONE NEGATIVE PRESSURE CONDENSATE DRAIN TRAP DETAIL CLEAN OUT PITCH DOWN TOWARD DRAIN CLEAN OUT DRAIN SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN FLOOR DRAIN AIR HANDLING UNIT DRAIN PAN 1" B A P = NEGATIVE PRESSURE (IN OF WATER) A = 1/2P + 2 IN B = 1 1/2P + 2 IN P SCALE: NONE TYPICAL EXHAUST FAN (FLAT) DETAIL MOTOR DISCONNECT SWITCH BY UNIT MFGR. PIGTAIL CORD EXTERNAL ALUM. WIRE POST BY UNIT MFGR. REFER TO ARCHITECTURAL PLANS FOR ROOF CONSTRUCTION AUTO BACKDRAFT DAMPER SEE PLANS FOR DUCT SIZE ALUM. HOUSING FAN WHEEL BIRDSCREEN FLASH AND COUNTERFLASH 16" HIGH PRE-FAB CURB PROVIDE HOLE THRU ROOF ROUTE WIRE OUTSIDE DAMPER, BY OTHERS ROOF CURB CAP SCALE: NONE ROOFTOP AIR HANDLING UNIT DRAIN DETAIL 8" M I N AIR HANDLING UNIT AHU DRAIN CONDENSATE DRAIN PIPE WITH INSULATION 1 1/2" INSULATION BY UNIT MANUF. L3x3x1/4 CONTINOUS (TYP EACH SIDE) CUT OPENINGS IN EXISTING ROOF AND DECK. ROOF CURB TO SIT ON EXISTING STRUCTURAL STEEL. SECURE AS REQUIRED SECURE ROOF CURB TO EXISTING STRUCTURE EXISTING ROOF SYSTEM ROOF FIELD APPLIED CANT CONDENSATE DRAIN THROUGH ROOF CURB COUNTER FLASHING ROOF CURB BY UNIT MANUFACTURER CURB RAIL BY UNIT MANUFACTURER GASKET BY UNIT MANUFACTURER EXISTING STRUCTURE SCALE: NONE TYPICAL AIR TERMINAL INSTALLATION DETAIL A.METALLIC FLEXIBLE DUCT SHALL BE ATTACHED USING A MINIMUM OF THREE #8 SHEET METAL SCREWS EQUALLY SPACED AROUND THE DUCT'S CIRCUMFERENCE; DUCTS LARGER THAN 12"∅ SHALL HAVE A MINIMUM OF FIVE #8 SHEET METAL SCREWS. SCREWS SHALL BE LOCATED AT LEAST 8" FROM THE DUCT END. B.NON-METALLIC FLEXIBLE DUCT SHALL BE SECURED TO THE SLEEVE OR COLLAR USING A DRAW BAND. IF THE DUCT COLLAR EXCEEDS 12"∅, THE DRAW BAND MUST BE POSITIONED BEHIND A BEAD ON THE METAL COLLAR. C.INSULATION AND VAPOR BARRIERS PRESENT ON FACTORY-FABRICATED DUCTS SHALL BE FITTED OVER THE CORE CONNECTION AND SHALL BE SUPPLEMENTALLY SECURED WITH A DRAW BAND. D.FLEXIBLE DUCT SEALING SHALL BE A CLASS "B" FOR LOW PRESSURE DUCT. SPECIFICATION FOR JOINING AND ATTACHING FLEXIBLE DUCT DUCTWORK SPIN-IN FITTING W/VOLUME DAMPER FLEXIBLE DUCT-MAXIMUM 6'-0" LENGTH AND NO MORE THAN TWO (2) 90° BENDS. SQUARE TO ROUND FITTING CEILINGAIR TERMINAL ELECTRIC HEAT ROOFTOP UNIT SCHEDULE NOTES: 1.PROVIDE ECONOMIZER. 2.PROVIDE VFD. 3. 4.PROVIDE AIR FLOW MEASURING STATIONS FOR OUTDOOR AIR. 5.PROVIDE DISCONNECT. 6.PROVIDE NETWORK CARD WITH BACNET PROTOCOL. BMS IS NOT IN THIS SCOPE OF WORK. PROVIDE RETURN AIR SMOKE DETECTOR. DUCTLESS SPLIT AIR CONDITIONER SCHEDULE NOTES: CONDENSING UNIT SCHEDULE NOTES: 1.PURON R-410A REFRIGERANT. 2.LOW AMBIENT KIT 3.DISCONNECT SWITCH BY EC. SPECIFICATION SECTION 237433 MARKLOCATION NOMINAL TONS FAN DATAFAN DATAFAN MOTOR DATA COOLING DATA MAX AMB TEMP MIN AMB TEMP MIN EER ELECTRIC HEATING DATAELECTRICAL DATAFILTER DATA UNIT WEIGHT (LBS) MANUFACTURER WITH MODEL NUMBERAIRFLOW CFM ESPMIN OA CFMRPMBHPWHEEL DIA.DRIVERPMHP TOTAL MBH SENS MBH EATLAT ROWSFINS/INCH MIN KW EATLATSTAGES MAX APD VOLTSPHASEMCAVOLTSPHTYPEEFF DBWBDBWB RTU-1ROOF2080001.5160011116.99-BELT8.637.5241.8187.9776454.753.8----117240602-20832002083MERV 13-3237 JOHNSON CONTROLS J20ZJC00M2HZZ3 RTU-2ROOF PROVIDE 14" ROOF CURB. 7. SPECIFICATION SECTION 238124 MARKLOCATION CFM COOLING MBH HEATING MBH ELECTRICAL DATA MANUFACTURER WITH MODEL NUMBER NOTES HIGHLOW WATTSAMPSVOLTSPH AC-1SEE PLANS95070534.237.05612081 MITSUBISHI PKA-A36KA4 1 1. CONNECT TO CONDENSING UNIT ACCU-1. MOUNT UNIT 8' ABOVE FINISHED FLOOR. PROVIDE CONDENSATE LIFT PUMP. SPECIFICATION SECTION 236201 MARKLOCATION CONNECT TO UNIT NOMINAL TONS DESIGN AMB TEMP MIN AMB TEMP MIN. SEER ELECTRICAL DATA LIQUID LINE SIZE SUCTION LINE SIZE UNIT WEIGHT (LBS) MANUFACTURER WITH MODEL NUMBER NOTES MCAVOLTSPH ACCU-1SEE PLANSAC-131151414.52520813/8"5/8"165 MITSUBISHI PUZ-A36NHA4 1, 2, 3 DESCRIPTION WHEEL SIZE DRIVE TYPECFMTSPBHPRPMSONESHPVOLTSPH ROOF CURB DISCONNECT SWITCH GRAVITY BACKDRAFT DAMPER VIBRATION ISOLATORS BIRD SCREEN EF-1ROOFDOWNBLASE-DIRECT9000.5.1414869.11/41151YESYESYESYESYES43GREENHECK G-101-A1 NOTES: 1.REFER TO ELECTRICAL DOCUMENTS FOR CONTROLS. PROVIDE SPEED CONTROLLER. PROVIDE 14" ROOF CURB. FACE SIZESLOT INFO CONN. SIZE DIRECTION DISTANCE @ NOM. CFM BALANCE DAMPER PLENUM BOOT TAMPER- PROOF SCREWS EG122524"x24"1/2"x1/2"x1/2"---LAY-IN.0320---PRICE 80 SPECIFICATION SECTION 233423 MARKLOCATION FAN DATA MOTOR DATA ACCESSORIES UNIT WEIGHT (LBS) MANUFACTURER WITH MODEL NUMBER NOTES SPECIFICATION SECTION 233713 MARKMAX CFM DIMENSIONAL DATATHROW DATA MOUNT PRESS. DROP (IN. WC.) MAX NC SOUND LEVEL ACCESSORIES MANUFACTURER WITH MODEL NUMBER FAN SCHEDULE DIFFUSERS & GRILLES SCHEDULE SCALE: NONE MIN KW MBH∆TAMPSVOLTSPH DISCONNECT SWITCH INTEGRAL THERMOSTAT WALL BRACKET EUH-1ELEVATOR LOBBYCEILING350310.22714.42081YESYESYESQMARK EFF40041 EUH-2ELEVATOR LOBBYCEILING350310.22714.42081YESYESYESQMARK EFF40041 NOTES: 1.PROVIDE WALL MOUNTING FRAME. SPECIFICATION SECTION 238201 MARKLOCATIONCONFIGURATION AIRFLOW (CFM) HEATING DATAELECTRICAL DATAACCESSORIES MANUFACTURER WITH MODEL NUMBER NOTES ELECTRIC UNIT HEATER SCHEDULE 4 2 3 5 ROOF EQUIPMENT CURB DETAIL COUNTER FLASHING (FIELD SUPPLIED) BASE FLASHING (FIELD SUPPLIED) 1/4" NEOPRENE RUBBER GASKET CONTINUOUS AROUND PERIMETER GALVANIZED METAL CURB (18 GA. MIN) JOIST WEB FIBER CANT STRIP SET IN BITUMEN (FIELD SUPPLIED) ROOF RIGID INSULATION (SEE ARCH) CONCRETE (SEE ARCH) MIN. 1-1/2", 3 LB RIGID INSULATION WITH NEOPRENE COATING ON EXPOSED SURFACE (FIELD SUPPLIED) SECURE CURB TO ROOF WITH STAINLESS OR GALVANIZED STEEL BOLTS (WELD CURB TO TOP CHORD AS ALTERNATE METHOD) COVER/CONTINUE ROOF INSIDE CURB OPENING AND PROVIDE SOUND DEADENING MATERIAL (L.W. CONCRETE OR SHEETROCK) TO PREVENT SOUND TRANSMISSION IN THE CEILING SPACE BELOW ROOF MOUNTED HVAC EQUIPMENT PRESSURE TREATED 2X4 WOOD NAILER (METAL STUDS WHERE REQ'D BY LOCAL A.H.J.) FASTENERS, 16" 0.C. 3/8" (#14) METAL SCREWS AT 18" O.C., LENGTH AS REQUIRED TO INSURE FULL DEPTH NAIL PENETRATION. PROVIDE SPACERS AS REQUIRED TO ACCOMMODATE ALTERNATE LOCATION ROOFTOP UNIT INSTALLATION NOTES: 1. DUCT TRANSITION FROM RTU TO DUCT SIZE SHOWN ON MECH. FLOOR PLAN SHALL BE MADE BETWEEN RTU & TOP OF ROOF WITHIN CURB. 2. SIZE OF OPENING IN ROOF DECK TO BE AS SMALL AS POSSIBLE, 6" MAXIMUM LARGER THAN DUCT SIZE SHOWN. COORDINATE W/STRUCTURAL PLANS. 3. INSTALL PER MANUFACTURER'S RECOMMENDATION AND INSTALLATION MANUAL. 4. ALL WIRING TO BE DONE BY ELECTRICAL CONTRACTOR. 5. SHIM CURB AS REQUIRED TO PROVIDE HORIZONTAL INSTALLATION OF UNIT WITHIN PRESCRIBED TOLERANCES. 6. CONTRACTOR SHALL COORDINATE LOCATION OF ROOF CURB WITH STRUCTURE PRIOR TO INSTALLATION. 7. ROOF CURB BY UNIT MANUFACTURER. PROVIDE ADDITIONAL BRACING AND SUPPORT AS REQUIRED FOR ROOF CURB INSTALLATION TO WITHSTAND WIND LOAD PER LOCAL CODES. 8. CURB TO BE HEAVY GAUGE GALVANIZED STEEL CONSTRUCTION AS RECOMMENDED BY MANUFACTURER, ALL FASTENERS SHALL BE CORROSIONPROTECTION IF EXPOSED TO OUTDOORS. A-BB-CA-C 0.51.01.0 ROOFTOP UNIT LEVELING TOLERANCES MAX. ALLOWABLE DIFFERENCE (in) A B C JOIST TOP CHORD WASHER AND NUT 14002 SE 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317.706.2075 www.enverityENG.com Project: Developer: Sheet Number: Engineer: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Enverity Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date Pe d c o r S q u a r e B u i l d i n g 5 35 7 C I T Y C E N T E R D R I V E Ca r m e l , I N , 4 6 0 3 2 PLAN NORTH THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. Construction Documents SE M-601 Mechanica Details and Schedules 12/18/1512/18/15