Loading...
HomeMy WebLinkAboutP-100B.pdfM 2" W 4" W4" W 3" W 1 5 6 6 76 1 6 5 2 2 1 CO 4 3 2 1 CO 23 2" CW 4" W 2" CW CO 18 17 16 19 10 12 1113 2021 14 15 22 22 8 9 .8A .8A A.3 A.3 C C E E F F H H K.2 K.2 L.5 L.5 v1 v1 v2 v2 v2.8 v2.8 v3 v3 v3.3 v3.3 v3.7 v3.7 v46 v46 v4.2 v4.2 v5 v5 4" ST ST 25 26 4" STORM INV. EL. @ 830.00' 27 27 A.REFER TO DRAWING M-000 FOR MECHANICAL, PLUMBING AND FIRE SUPPRESSION SYMBOLS AND ABBREVIATIONS. B.PROVIDE CEILING ACCESS PANELS TO SHUT-OFF VALVE, CONTROL VALVES, DRAIN VALVES, ETC. LOCATED ABOVE NON-ACCESSIBLE CEILINGS. COORDINATE ALL ACCESS PANELS WITH THE ARCHITECTURAL DRAWINGS. GENERAL PLUMBING NOTES 14002 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317.706.2075 www.enverityENG.com Project: Developer: Sheet Number: Engineer: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Enverity Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date Pe d c o r S q u a r e B u i l d i n g 5 35 7 C I T Y C E N T E R D R I V E Ca r m e l , I N , 4 6 0 3 2 PLAN NORTH THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. Construction Documents GRJK P-100B Plumbing Upper Parking Level Plan 12/18/1512/18/15 0 16'8'4' 1/8" = 1'-0" Plumbing Upper Parking Level Plan1 SHEET KEYNOTES 12" WASTE UP. 22" WASTE WITH DEEP SEAL P-TRAP UP TO FLOOR DRAIN. 31 1/2" VENT UP. 43" WASTE WITH DEEP SEAL P-TRAP UP TO MOP BASIN. 52" VENT UP. 63" WASTE UP TO WATER CLOSET. 74" WASTE UP. 8INSTALL PIPING AS HIGH AS POSSIBLE. 92"CW UP. 104" WASTE DOWN THRU FLOOR. 11EXISTING FLOOR DRAIN. 12EXISTING 2" CW SERVICE ROUGH-IN. 13CONNECT 2"CW TO EXISTING 2"CW SERVICE ROUGH-IN, COORDINATE WITH WATER UTILITY COMPANY. 14WATER METER, REFER TO DETAIL #?/P-501. 15BACKFLOW PREVENTER (BFP-1), REFER TO DETAIL #?/P-501. 16DOMESTIC WATER BOOSTER PUMP (DWBP-1), REFER TO DETAIL #?/P-501. 17CONNECT 3/4"CW TO EXISTING 3/4"CW LINE TO EXISTING HOSE BIBBS. 18EXISTING 3/4"CW LINE TO HOSE BIBBS. 19CAP OR REMOVE SECTION OF 3/4"CW NOT USED. 20PROVIDE A VALVE AND CAPPED 3/4"CW CONNECT FOR IRRIGATION WATER METER. 21EXISTING IRRIGATION BACKFLOW PREVENTER. 22EXISTING 3/4"CW LINE FOR IRRIGATION SUPPLY. 234" STORM FROM ABOVE. 254" STORM LINE DROP. PROVIDE CO AT BASE AND EXTEND THRU EXTERIOR WALL. 26SEE CIVIL DRAWINGS FOR CONTINUATION. 27PROVIDE INSULATION AND ELECTRIC HEAT TRACING ON CW LINE IN THE UNHEATED PARKING LEVEL AREA. NOTE: F.F.E. = 837.074' UPPER PARKING LEVEL FLOOR ELEV. = 826.574' LOWER PARKING LEVEL FLOOR ELEV. = 816.574'