Loading...
HomeMy WebLinkAbout07 11 16 Cementitious and Reactive Waterproofing.docPEDCOR SQUARE; BUILDING 5 07 11 16 - PEDCOR SQUARE CEMENTITIOUS AND REACTIVE Issue Date 12.18.15 WATERPROOFING PEDCOR SQUARE; BUILDING 5 SECTION 07 11 16 – CEMENTITIOUS AND REACTIVE WATERPROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes the following: 1. Exposed surfaces of cast-in-place concrete walls. 1.3 SUBMITTALS A. Product Data: For each type of product indicated. B. Material Certificates: For each product, signed by manufacturers. 1.4 QUALITY ASSURANCE A. Source Limitations: Obtain primary damp-proofing materials and primers through one source from a single manufacturer. Provide secondary materials recommended by manufacturer of primary materials. B. Qualifications: 1. Manufacturer: Company with minimum 15 years of experience in manufacturing of specified products and systems. 2. Applicator: Company with a minimum of 5 years experience in successful application of the specified products and systems on projects of similar size and scope, and is acceptable to the manufacturer. C. Field Sample: Approval of field sample required by Architect before Contractor may proceed with the complete application. PART 2 - PRODUCTS 2.1 CEMENTITIOUS AND REACTIVE WATER-PROOFING A. Manufacturers: Provide products by the following: 1. Degussa Building Systems. B. Products: 1. Standard Coating: Thoroseal Waterproof Cement Based Coating. PEDCOR SQUARE; BUILDING 5 07 11 16 - PEDCOR SQUARE CEMENTITIOUS AND REACTIVE Issue Date 12.18.15 WATERPROOFING PEDCOR SQUARE; BUILDING 5 a. Color: To be selected by Architect. 2. Plaster Mix: Thoroseal Plaster Mix. 3. Waterstop: Thoroseal Waterplug. 2.2 MIXING A. Mix material per manufacturer instructions allowing material to rest 15 minutes before remixing and application. B. Color: To be selected by Architect. PART 3 - EXECUTION 3.1 APPLICATION, GENERAL A. Comply with manufacturer's written recommendations unless more stringent requirements are indicated or required by Project conditions to ensure satisfactory performance. 3.2 BELOW GRADE APPLICATION A. Follow manufacturer’s written instructions. END OF SECTION 07 11 16