HomeMy WebLinkAbout07 21 00 Thermal Insulation.DOCPEDCOR SQUARE; BUILDING 5
07 21 00 -
PEDCOR SQUARE Issue Date 12.18.15 THERMAL INSULATION
PEDCOR SQUARE; BUILDING 5
SECTION 07 21 00 - THERMAL INSULATION
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Foam-plastic board insulation.
2. Glass-fiber blanket insulation.
3. Mineral-wool blanket insulation.
4. Vapor retarders.
B. Related Sections:
1. Section 04 20 00 "Unit Masonry" for insulation installed in cavity walls and masonry cells.
2. Section 06 16 00 "Sheathing" for gypsum board sheathing over wood or steel framing.
3. Section 071251 "SBS Modified Sheet Waterproofing."
4. Section 07 24 13 "Water-Drainage Exterior Insulation and Finish System (EIFS)" for
insulation specified as part of these systems.
5. Section 07 84 43 "Fire-Resistive Joint Systems" for insulation installed as part of a
perimeter fire-resistive joint system.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product indicated.
1.4 INFORMATIONAL SUBMITTALS
A. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified
testing agency, for each product.
B. Research/Evaluation Reports: For foam-plastic insulation, from ICC-ES.
1.5 QUALITY ASSURANCE
A. Surface-Burning Characteristics: As determined by testing identical products according to
ASTM E 84 by a qualified testing agency. Identify products with appropriate markings of
applicable testing agency.
PEDCOR SQUARE; BUILDING 5
07 21 00 -
PEDCOR SQUARE Issue Date 12.18.15 THERMAL INSULATION
PEDCOR SQUARE; BUILDING 5
1.6 DELIVERY, STORAGE, AND HANDLING
A. Protect insulation materials from physical damage and from deterioration due to moisture,
soiling, and other sources. Store inside and in a dry location. Comply with manufacturer's
written instructions for handling, storing, and protecting during installation.
B. Protect foam-plastic board insulation as follows:
1. Do not expose to sunlight except to necessary extent for period of installation and
concealment.
2. Protect against ignition at all times. Do not deliver foam-plastic board materials to Project
site before installation time.
3. Quickly complete installation and concealment of foam-plastic board insulation in each
area of construction.
PART 2 - PRODUCTS
2.1 FOAM-PLASTIC BOARD INSULATION
A. Extruded-Polystyrene Board Insulation: ASTM C 578, of type and minimum compressive
strength indicated below, with maximum flame-spread and smoke-developed indexes of 75 and
450, respectively, per ASTM E 84.
1. Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
a. DiversiFoam Products.
b. Dow Chemical Company (The).
c. Owens Corning.
d. Pactiv Building Products.
2. Type IV, 25 psi.
B. Unfaced Wall Insulation Drainage Panels: Extruded-polystyrene board insulation complying
with ASTM C 578, Type IV, 25-psi minimum compressive strength; unfaced; fabricated with
shiplap or channel edges and with one side having grooved drainage channels.
1. Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
a. DiversiFoam Products.
b. Dow Chemical Company (The).
c. Pactiv Building Products.
C. Foil-Faced, Polyisocyanurate Board Insulation: ASTM C 1289, Type I, Class 1, with maximum
flame-spread and smoke-developed indexes of 75 and 450, respectively, per ASTM E 84.
1. Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
a. Atlas Roofing Corporation.
b. Dow Chemical Company (The).
c. Rmax, Inc.
D. Adhesive for Bonding Insulation: Product with demonstrated capability to bond insulation
securely to substrates without damaging insulation and substrates.
PEDCOR SQUARE; BUILDING 5
07 21 00 -
PEDCOR SQUARE Issue Date 12.18.15 THERMAL INSULATION
PEDCOR SQUARE; BUILDING 5
2.2 GLASS-FIBER BLANKET INSULATION
A. Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
1. CertainTeed Corporation.
2. Guardian Building Products, Inc.
3. Johns Manville.
4. Knauf Insulation.
5. Owens Corning.
B. Recycled Content: Post-consumer recycled content plus one-half of pre-consumer recycled
content not less than 25 percent.
C. Unfaced, Glass-Fiber Blanket Insulation: ASTM C 665, Type I; with maximum flame-spread and
smoke-developed indexes of 25 and 50, respectively, per ASTM E 84; passing ASTM E 136 for
combustion characteristics.
D. Kraft-Faced, Glass-Fiber Blanket Insulation: ASTM C 665, Type II (non-reflective faced),
Class C (faced surface not rated for flame propagation); Category 1 (membrane is a vapor
barrier).
E. Eave Ventilation Troughs: Preformed, rigid fiberboard or plastic sheets designed and sized to fit
between roof framing members and to provide cross ventilation between insulated attic spaces
and vented eaves.
F. Sustainability Requirements: Provide glass-fiber blanket insulation as follows:
1. Free of Formaldehyde: Insulation manufactured with 100 percent acrylic binders and no
formaldehyde.
2. Low Emitting: Insulation tested according to ASTM D 5116 and shown to emit less than
0.05-ppm formaldehyde.
2.3 MINERAL-WOOL BLANKET INSULATION
A. Manufacturers: Subject to compliance with requirements, available manufacturers offering
products that may be incorporated into the Work include, but are not limited to, the following:
1. Fibrex Insulations Inc.
2. Owens Corning.
3. Thermafiber.
B. Recycled Content: Post-consumer recycled content plus one-half of pre-consumer recycled
content not less than 25 percent.
C. Unfaced, Mineral-Wool Blanket Insulation: ASTM C 665, Type I (blankets without membrane
facing); consisting of fibers; with maximum flame-spread and smoke-developed indexes of 25
and 50, respectively, per ASTM E 84; passing ASTM E 136 for combustion characteristics.
2.4 VAPOR RETARDERS
A. Polyethylene Vapor Retarders: ASTM D 4397, 10 mils thick, with maximum permeance rating
of 0.13 perms.
PEDCOR SQUARE; BUILDING 5
07 21 00 -
PEDCOR SQUARE Issue Date 12.18.15 THERMAL INSULATION
PEDCOR SQUARE; BUILDING 5
B. Vapor-Retarder Tape: Pressure-sensitive tape of type recommended by vapor-retarder
manufacturer for sealing joints and penetrations in vapor retarder.
C. Single-Component Non-sag Urethane Sealant: ASTM C 920, Type I, Grade NS, Class 25,
use NT related to exposure, and Use O related to vapor-barrier-related substrates.
D. Adhesive for Vapor Retarders: Product recommended by vapor-retarder manufacturer and has
demonstrated capability to bond vapor retarders securely to substrates indicated.
2.5 INSULATION FASTENERS
A. Adhesively Attached, Spindle-Type Anchors: Plate welded to projecting spindle; capable of
holding insulation of specified thickness securely in position indicated with self-locking washer in
place.
1. Products: Subject to compliance with requirements, available products that may be
incorporated into the Work include, but are not limited to, the following:
a. AGM Industries, Inc.; Series T TACTOO Insul-Hangers.
b. Gemco; Spindle Type.
2. Plate: Perforated, galvanized carbon-steel sheet, 0.030 inch thick by 2 inches square.
3. Spindle: Copper-coated, low-carbon steel; fully annealed; 0.105 inch in diameter; length
to suit depth of insulation indicated.
B. Insulation-Retaining Washers: Self-locking washers formed from 0.016-inch- thick galvanized-
steel sheet, with beveled edge for increased stiffness, sized as required to hold insulation
securely in place, but not less than 1-1/2 inches square or in diameter.
1. Products: Subject to compliance with requirements, provide one of the following:
a. AGM Industries, Inc.; RC150.
b. Gemco; R-150.
2. Protect ends with capped self-locking washers incorporating a spring steel insert to
ensure permanent retention of cap in the following locations:
a. Crawl spaces.
b. Ceiling plenums.
c. Attic spaces.
d. Where indicated.
C. Insulation Standoff: Spacer fabricated from galvanized mild-steel sheet for fitting over spindle of
insulation anchor to maintain air space of 1 inch between face of insulation and substrate to
which anchor is attached.
1. Products: Subject to compliance with requirements, provide the following:
a. Gemco; Clutch Clip.
D. Anchor Adhesive: Product with demonstrated capability to bond insulation anchors securely to
substrates indicated without damaging insulation, fasteners, and substrates.
1. Products: Subject to compliance with requirements, provide one of the following:
a. AGM Industries, Inc.; TACTOO Adhesive.
b. Gemco; Tuff Bond Hanger Adhesive.
PEDCOR SQUARE; BUILDING 5
07 21 00 -
PEDCOR SQUARE Issue Date 12.18.15 THERMAL INSULATION
PEDCOR SQUARE; BUILDING 5
PART 3 - EXECUTION
3.1 PREPARATION
A. Clean substrates of substances that are harmful to insulation or vapor retarders, including
removing projections capable of puncturing vapor retarders, or that interfere with insulation
attachment.
3.2 INSTALLATION, GENERAL
A. Comply with insulation manufacturer's written instructions applicable to products and
applications indicated.
B. Install insulation that is undamaged, dry, and unsoiled and that has not been left exposed to ice,
rain, or snow at any time.
C. Extend insulation to envelop entire area to be insulated. Cut and fit tightly around obstructions
and fill voids with insulation. Remove projections that interfere with placement.
D. Provide sizes to fit applications indicated and selected from manufacturer's standard
thicknesses, widths, and lengths. Apply single layer of insulation units to produce thickness
indicated unless multiple layers are otherwise shown or required to make up total thickness.
3.3 INSTALLATION OF BELOW-GRADE INSULATION
A. On vertical surfaces, set insulation units using manufacturer's recommended adhesive
according to manufacturer's written instructions.
1. If not otherwise indicated, extend insulation a minimum of 24 inches below exterior grade
line.
B. On horizontal surfaces, loosely lay insulation units according to manufacturer's written
instructions. Stagger end joints and tightly abut insulation units.
1. If not otherwise indicated, extend insulation a minimum of 24 inches in from exterior
walls.
3.4 INSTALLATION OF CAVITY-WALL INSULATION
A. Foam-Plastic Board Insulation: Install pads of adhesive spaced approximately 24 inches o.c.
both ways on inside face, and as recommended by manufacturer. Fit courses of insulation
between wall ties and other obstructions, with edges butted tightly in both directions. Press
units firmly against inside substrates.
1. Supplement adhesive attachment of insulation by securing boards with two-piece wall
ties designed for this purpose and specified in Section 04 20 00 "Unit Masonry."
PEDCOR SQUARE; BUILDING 5
07 21 00 -
PEDCOR SQUARE Issue Date 12.18.15 THERMAL INSULATION
PEDCOR SQUARE; BUILDING 5
3.5 INSTALLATION OF INSULATION FOR FRAMED CONSTRUCTION
A. Apply insulation units to substrates by method indicated, complying with manufacturer's written
instructions. If no specific method is indicated, bond units to substrate with adhesive or use
mechanical anchorage to provide permanent placement and support of units.
B. Foam-Plastic Board Insulation: Seal joints between units by applying adhesive, mastic, or
sealant to edges of each unit to form a tight seal as units are shoved into place. Fill voids in
completed installation with adhesive, mastic, or sealant as recommended by insulation
manufacturer.
C. Glass-Fiber or Mineral-Wool Blanket Insulation: Install in cavities formed by framing members
according to the following requirements:
1. Use insulation widths and lengths that fill the cavities formed by framing members. If
more than one length is required to fill the cavities, provide lengths that will produce a
snug fit between ends.
2. Place insulation in cavities formed by framing members to produce a friction fit between
edges of insulation and adjoining framing members.
3. Maintain 3-inch clearance of insulation around recessed lighting fixtures not rated for or
protected from contact with insulation.
4. Install eave ventilation troughs between roof framing members in insulated attic spaces at
vented eaves.
5. For wood-framed construction, install blankets according to ASTM C 1320 and as follows:
a. With faced blankets having stapling flanges, secure insulation by inset, stapling
flanges to sides of framing members.
b. With faced blankets having stapling flanges, lap blanket flange over flange of
adjacent blanket to maintain continuity of vapor retarder once finish material is
installed over it.
D. Miscellaneous Voids: Install insulation in miscellaneous voids and cavity spaces where required
to prevent gaps in insulation.
3.6 INSTALLATION OF INSULATION IN CEILINGS FOR SOUND ATTENUATION
A. Where glass-fiber blankets are indicated for sound attenuation above ceilings, install blanket
insulation over entire ceiling area in thicknesses indicated. Extend insulation 48 inches up
either side of partitions.
3.7 INSTALLATION OF INSULATION FOR CONCRETE SUBSTRATES
A. Install board insulation on concrete substrates by adhesively attached, spindle-type insulation
anchors as follows:
1. Fasten insulation anchors to concrete substrates with insulation anchor adhesive
according to anchor manufacturer's written instructions. Space anchors according to
insulation manufacturer's written instructions for insulation type, thickness, and
application indicated.
2. Apply insulation standoffs to each spindle to create cavity width indicated between
concrete substrate and insulation.
3. After adhesive has dried, install board insulation by pressing insulation into position over
spindles and securing it tightly in place with insulation-retaining washers, taking care not
to compress insulation below indicated thickness.
PEDCOR SQUARE; BUILDING 5
07 21 00 -
PEDCOR SQUARE Issue Date 12.18.15 THERMAL INSULATION
PEDCOR SQUARE; BUILDING 5
4. Where insulation will not be covered by other building materials, apply capped washers to
tips of spindles.
3.8 INSTALLATION OF VAPOR RETARDERS
A. Place vapor retarders on side of construction indicated on Drawings. Extend vapor retarders to
extremities of areas to protect from vapor transmission. Secure vapor retarders in place with
adhesives or other anchorage system as indicated. Extend vapor retarders to cover
miscellaneous voids in insulated substrates, including those filled with loose-fiber insulation.
B. Seal vertical joints in vapor retarders over framing by lapping no fewer than two studs.
1. Fasten vapor retarders to wood framing at top, end, and bottom edges; at perimeter of
wall openings; and at lap joints. Space fasteners 16 inches o.c.
2. Locate all joints over framing members or other solid substrates.
3. Firmly attach vapor retarders to solid substrates with vapor-retarder fasteners as
recommended by vapor-retarder manufacturer.
C. Seal joints caused by pipes, conduits, electrical boxes, and similar items penetrating vapor
retarders with vapor-retarder tape to create an airtight seal between penetrating objects and
vapor retarders.
D. Repair tears or punctures in vapor retarders immediately before concealment by other work.
Cover with vapor-retarder tape or another layer of vapor retarders.
3.9 PROTECTION
A. Protect installed insulation and vapor retarders from damage due to harmful weather exposures,
physical abuse, and other causes. Provide temporary coverings or enclosures where insulation
is subject to abuse and cannot be concealed and protected by permanent construction
immediately after installation.
END OF SECTION 07 21 00