HomeMy WebLinkAbout10 26 00 - Wall and Door Protection.DOCPEDCOR SQUARE; BUILDING 5
10 26 00 -
PEDCOR SQUARE Issue Date 12.18.15 WALL PROTECTION
PEDCOR SQUARE; BUILDING 5
SECTION 10 26 00 - WALL PROTECTION
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Corner guards.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
1. Include construction details, material descriptions, impact strength, dimensions of
individual components and profiles, and finishes.
2. Include fire ratings of units recessed in fire-rated walls and listings for door-protection
items attached to fire-rated doors.
B. Shop Drawings: For each type of wall and door protection showing locations and extent.
1. Include plans, elevations, sections, and attachment details.
1.4 INFORMATIONAL SUBMITTALS
A. Sample Warranty: For special warranty.
1.5 CLOSEOUT SUBMITTALS
A. Maintenance Data: For each type of wall and door protection product to include in maintenance
manuals.
1.6 MAINTENANCE MATERIAL SUBMITTALS
A. Furnish extra materials, from the same product run, that match products installed and that are
packaged with protective covering for storage and identified with labels describing contents.
1.7 QUALITY ASSURANCE
A. Manufacturer Qualifications: Refer to Specification Section 01 40 00 “Quality Requirements.”
PEDCOR SQUARE; BUILDING 5
10 26 00 -
PEDCOR SQUARE Issue Date 12.18.15 WALL PROTECTION
PEDCOR SQUARE; BUILDING 5
B. Vendor Qualifications: Refer to Specification Section 01 40 00 “Quality Requirements.”
1.8 DELIVERY, STORAGE, AND HANDLING
A. Store wall protection in original undamaged packages and containers inside well-ventilated area
protected from weather, moisture, soiling, extreme temperatures, and humidity.
1.9 WARRANTY
A. Special Warranty: Manufacturer agrees to repair or replace components of wall- protection units
that fail in materials or workmanship within specified warranty period.
1. Failures include, but are not limited to, the following:
a. Structural failures including detachment of components from each other or from
the substrates, delamination, and permanent deformation beyond normal use.
b. Deterioration of metals, metal finishes, plastics, and other materials beyond normal
use.
2. Warranty Period: Five years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Source Limitations: Obtain wall-protection products of each type from single source from single
manufacturer.
2.2 PERFORMANCE REQUIREMENTS
A. Surface Burning Characteristics: Comply with ASTM E 84 or UL 723; testing by a qualified
testing agency. Identify products with appropriate markings of applicable testing agency.
1. Flame-Spread Index: 25 or less.
2. Smoke-Developed Index: 450 or less.
B. Regulatory Requirements: Comply with applicable provisions in the U.S. Architectural &
Transportation Barriers Compliance Board's ADA-ABA Accessibility Guidelines for Buildings and
Facilities and ICC A117.1.
2.3 CORNER GUARDS
A. Surface-Mounted, Metal Corner Guards: Fabricated as one piece from formed or extruded
metal with formed edges; with 90- or 135-degree turn to match wall condition.
1. Manufacturers: Subject to compliance with requirements, provide products by the
following:
a. Korogard Wall Protection Systems.
b. Rockwood Manufacturing.
c. Pawling Corporation.
d. Construction Specialties.
PEDCOR SQUARE; BUILDING 5
10 26 00 -
PEDCOR SQUARE Issue Date 12.18.15 WALL PROTECTION
PEDCOR SQUARE; BUILDING 5
2. Material: Stainless-steel sheet, Type 304.
a. Thickness: Minimum 0.0500 inch.
b. Finish: Directional satin, No. 4.
3. Wing Size: Nominal 1-1/2 by 1-1/2 inches.
4. Corner Radius: 1/8 inch.
5. Mounting: Flat-head, countersunk screws through factory-drilled mounting holes.
2.4 MATERIALS
A. Fasteners: Aluminum, nonmagnetic stainless-steel, or other noncorrosive metal screws, bolts,
and other fasteners compatible with items being fastened. Use security-type fasteners where
exposed to view.
2.5 FABRICATION
A. Fabricate wall protection according to requirements indicated for design, performance,
dimensions, and member sizes, including thicknesses of components.
B. Factory Assembly: Assemble components in factory to greatest extent possible to minimize field
assembly. Disassemble only as necessary for shipping and handling.
C. Quality: Fabricate components with uniformly tight seams and joints and with exposed edges
rolled. Provide surfaces free of wrinkles, chips, dents, uneven coloration, and other
imperfections. Fabricate members and fittings to produce flush, smooth, and rigid hairline joints.
2.6 FINISHES
A. Protect finishes on exposed surfaces from damage by applying a strippable, temporary
protective covering before shipping.
B. Appearance of Finished Work: Noticeable variations in same piece are not acceptable.
Variations in appearance of adjoining components are acceptable if they are within the range of
approved Samples and are assembled or installed to minimize contrast.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates and wall areas, with Installer present, for compliance with requirements for
installation tolerances, fire rating, and other conditions affecting performance of the Work.
B. Examine walls to which wall protection will be attached for blocking, grounds, and other solid
backing that have been installed in the locations required for secure attachment of support
fasteners.
C. Proceed with installation only after unsatisfactory conditions have been corrected.
PEDCOR SQUARE; BUILDING 5
10 26 00 -
PEDCOR SQUARE Issue Date 12.18.15 WALL PROTECTION
PEDCOR SQUARE; BUILDING 5
3.2 PREPARATION
A. Complete finishing operations, including painting, before installing wall and door protection.
B. Before installation, clean substrate to remove dust, debris, and loose particles.
3.3 INSTALLATION
A. Installation Quality: Install wall protection according to manufacturer's written instructions, level,
plumb, and true to line without distortions. Do not use materials with chips, cracks, voids, stains,
or other defects that might be visible in the finished Work.
B. Mounting Heights: Install wall protection in locations and at mounting heights indicated on
Drawings.
C. Accessories: Provide splices, mounting hardware, anchors, trim, joint moldings, and other
accessories required for a complete installation.
1. Provide anchoring devices and suitable locations to withstand imposed loads.
2. Adjust top caps as required to ensure tight seams.
3.4 CLEANING
A. Immediately after completion of installation, clean plastic covers and accessories using a
standard ammonia-based household cleaning agent.
B. Remove excess adhesive using methods and materials recommended in writing by
manufacturer.
END OF SECTION 10 26 00