Loading...
HomeMy WebLinkAboutA002 Wall Legend and UL Assemblies.pdfProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date EJD, RJP, DJS, JAW, AJR JAW BALDWIN CHAMBERS BUILDING 800 South Rangeline Road Carmel, IN, 46032 E R 28 22 16 H 11 SCALE: NTS PLAN NORTH KEY PLAN Bldg C PEDCOR DESIGN GROUP LLC A002 Wall Legend and UL Assemblies THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL ANDPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2016JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 100% Construction Documents 04/08/16 100% Design Development 04/13/15 Friday, April 8, 2016, BIM Server: PDGBIM - BIM Server 19/BLDG C/Building C 6" 8" 1' 1'-4" 7 5/8" 2"7 5/8" 11 5/8" 1 5/8" 2 1/2" 3 5/8" 3 5/8" 3 5/8" 3 5/8" 9 1/2" C6 C8 C12 C16 M8 M8N M12 S1.5A S2.5A S3.5A S3.5B S3.5Bi S3.5E S3.5Ji S4H 1HR S6 M12 6" CAST-IN-PLACE REINFORCED CONCRETE WALL; REF. TO S-SERIES DWGS. FOR DETAILS WALL LEGEND BRIEF DESCRIPTION FIRE RATING UL LISTING STC RATING THICKNESS 8" CONCRETE MASONRY WALL; REF. S-SERIES DWGS. FOR GROUTING AND REINFORCING DETAILS 1-5/8" METAL STUD WALL; 5/8" GYP. BD. ONE SIDE; 22 GAUGE MTL. STUD MINIMUM @ 16" O.C. 2-1/2" METAL STUD WALL; 5/8" GYP. BD. ONE SIDE; 22 GAUGE MTL. STUD MINIMUM @ 16" O.C. 6" 8" 12" 1'-4" 7 5/8" 7 5/8" 11 5/8" 2 1/4" 3 1/8" 4 1/4" 4 7/8" 4 7/8" 4 1/4" 10 3/4" 3 1/8" 6" - - - - - - - - - - - - - - - - 45-49 45-49 - - 50 40-44 - - - - - - - - - - - - - - - - - - - - - - U465 - - V488 U417 - - U465 - - - - - - 1 - - - - 1 1 1 2 OR 1 HOUR TABLE 721.1 (2) ITEM 4-1.1 1-4 HOURS TABLE 721.1 (2) ITEM 4-1.1 1-4 HOURS TABLE 721.1 (2) ITEM 4-1.1 1-4 HOURS TABLE 721.1 (2) ITEM 4-1.1 4 HOURS TABLE 721.1 (2) ITEM 3-1.1 OR ITEM 3-1.4 4 HOURS TABLE 721.1 (2) ITEM 3-1.1 OR ITEM 3-1.4 4 HOURS TABLE 721.1 (2) ITEM 3-1.1 OR ITEM 3-1.4 8" CAST-IN-PLACE REINFORCED CONCRETE WALL; REF. TO S-SERIES DWGS. FOR DETAILS 12" CAST-IN-PLACE REINFORCED CONCRETE WALL; REF. TO S-SERIES DWGS. FOR DETAILS 16" CAST-IN-PLACE REINFORCED CONCRETE WALL; REF. TO S-SERIES DWGS. FOR DETAILS 12" CONCRETE MASONRY WALL; REF. S-SERIES DWGS. FOR GROUTING AND REINFORCING DETAILS 8" CONCRETE MASONRY WALL WITH 2" AIR SPACE; REF. S-SERIES DWGS. FOR GROUTING AND REINFORCING DETAILS 3-5/8" METAL STUD WALL; 5/8" GYP. BD. ONE SIDE; 22 GAUGE MTL. STUD MINIMUM @ 16" O.C. 3-5/8" METAL STUD WALL; @ 16" O.C. 5/8" GYP. BD. BOTH SIDES; SEE U.L. DESCRIPTION FOR MTL. STUD MIN. GA. NOTE: S-SERIES DWGS MAY REQUIRE THICKER GA. AND DIFFERENT SPACING 3-5/8" METAL STUD WALL; @16" O.C. 5/8" GYP. BD. BOTH SIDES; BATT INSULATION (FULL WIDTH) R-13 SEE U.L. DESCRIPTION FOR MTL. STUD MIN. GA. NOTE: S-SERIES DWGS MAY REQUIRE THICKER GA. AND DIFFERENT SPACING 3-5/8" METAL STUD WALL; @16" O.C. 5/8" GREEN BD. ONE SIDE; 22 GAUGE MTL. STUD MINIMUM 1-1/2" METAL STUD WALL; 5/8" GYP. BD. ONE SIDE; 1-1/2" RIGID INSULATION; 1" LINER PANEL; SEE U.L. DESCRIPTION FOR MTL. STUD MIN. GA. 6" METAL STUD WALL; @16" O.C. 22 GAUGE MTL. STUD MINIMUM 2 WYTHES OF 3-5/8" METAL STUD WALLS: @16" O.C. STAGGERED 5/8" GYP. BOARD; 3-5/8" MTL. STUD BATT INSULATION (FULL WIDTH) R-13 HD 5/8" PLYWOOD 1" AIRSPACE 5/8" PLYWOOD 3-5/8" MTL. STUD BATT INSULATION (FULL WIDTH) R-13 HD 5/8" GYP. BOARD REF. TO S-SERIES DWGS FOR MTL. STUD GAUGE PLAN VIEW SECTION VIEW RATED RATED RATED RATED RATED RATED X X X X X 7" 5 1/2" A B C D E F G FLOOR/CEILING: 5-1/2" COMPOSITE SLAB (2 Hr and 3HR. ASSEMBLY REQUIRES FIREPROOF DECK); SPRAY-ON FIRE PROOF STEEL FRAMING ROOF & FLOOR LEGEND SYMBOL SECTION VIEW DESCRIPTION UL LISTING IIC RATING ASSEMBLY DEPTH (X) - - - - 1 HOUR: D902 3 HOUR: D832 BEAM ONLY: N823 COMPOSITE SLAB COMPOSITE SLAB ACOUSTIC TOPPING 1 HOUR: D902 COMPOSITE SLAB ACOUSTIC TOPPING BATT INSULATION LIGHT GAUGE MTL. TRUSS ROOF MEMBRANE 4" RIGID INSULATION METAL DECK LIGHT GAUGE MTL. TRUSS 1 HOUR G566 1 HOUR P540 1 HOUR GA FILE NO. FC 1130 1 HOUR D902 5-1/2" plus steel depth 7" plus steel depth 55 - 58 - - 2'-8 5/16" VARIES - - 3'-0 1/4" - -VARIES ACOUSTIC TOPPING COMPOSITE SLAB 5/8" TYPE X GYP. BOARD ROOF MEMBRANE 5/8" RECOVERY BOARD 4" RIGID INSULATION VAPOR BARRIOR MTL. DECK 5/8" TYPE X GYP.BOARD ROOF MEMBRANE COMPOSITE DECK STEEL FRAMING STEEL FRAMING STEEL FRAMING FLOOR/CEILING: 1-1/8" LT. WT. AGG. CONC. TOPPING; 3/8" Maxxon Enkasonic; 5-1/2" COMPOSITE SLAB; SPRAY-ON FIRE PROOF STEEL FRAMING FLOOR/CEILING: 1-1/8" LT. WT. AGG. CONC. TOPPING;3/8" Maxxon Enkasonic; 3-1/2" COMPOSITE SLAB; R-11 BATT INSULATION; LIGHT GUAGE MTL. TRUSS; RC CHANNEL; 5/8" TYPE X GYP. BOARD ROOF/CEILING: ROOF MEMBRANE; 5/8" RECOVERY BOARD; 4" RIGID INSULATION; VAPOR BARRIOR; FIRE PROOF METAL DECK; BATT INSULATION; RC CHANNEL; 5/8" TYPE X GYP. BOARD FLOOR/CEILING: 1-1/8" LT. WT. AGG. CONC. TOPPING; 3/8" Maxxon Enkasonic; 3-1/2" COMPOSITE SLAB BATT INSULATION; 5/8" TYPE X GYP. BOARD 3 5/8" CFS FRAMING ROOF/CEILING: ROOF MEMBRANE; 5/8" RECOVERY BOARD 4" RIGID INSULATION; VAPOR BARRIOR; METAL DECK; BATT INSULATION; 5/8" TYPE X GYP. BOARD 3 5/8" CFS FRAMING ROOF/CEILING: ROOF MEMBRANE; 5/8' RECOVERY BOARD 4" RIGID INSULATION; VAPOR BARRIOR; 5 1/2" COMPOSITE SLAB; SPRAY ON FIRE PROOF STEEL FRAMING BATT INSULATION 1 HOUR GA FILE NO. FC 1130 RC CHANNEL 5/8"TYPE X GYP. BD. CFS FRAMING 3 5/8" CFS FRAMING 5/8" RECOVERY BOARD 3 5/8" CFS FRAMING 16" O.C. 4" RIGID INSULATION STC RATING - - - - 58 - 61 - - - - - - VARIES S6Ai S6B S6Bi S6D S6Di S6O S8D S8Di S8O S6Oi S8Ni 6 5/8" 7 1/4" 7 1/4" 7 1/4" 7 1/4" 6 5/8" 9 1/4" 9 1/4" - - 45-49 45-49 45-49 45-49 45-49 45-49 U465 - - - -- - - - - - U465 U465 V465 U465 U465 1 1 1 1 1 1 6" METAL STUD WALL; @16" O.C. BATT INSULATION (FULL WIDTH) R-21; 5/8" GYP. BD. ONE SIDE; 22 GAUGE MTL. STUD MINIMUM 6" METAL STUD WALL; @16" O.C. 5/8" GYP. BD. BOTH SIDES; REF. S-SERIES DWGS. FOR MTL. STUD GAUGE 6" METAL STUD WALL; BATT INSULATION (FULL WIDTH) R-21 5/8" GYP. BD. BOTH SIDES; REF. TO S-SERIES DWGS. FOR MTL. STUD GAUGE NOTE: S-SERIES DWGS MAY REQUIRE THICKER GA. AND DIFFERENT SPACING 6" NON-LOAD BEA RING MTL. STUD WALL; 5/8" GYP. BD. ONE SIDE; 5/8" GLASS-MAT GYPSUM SHEATHING BOARD ONE SIDE; REF. S-SERIES DRAWINGS FOR STUD TYPE, SPACING, AND GAUGE NOTE: S-SERIES DWGS MAY REQUIRE THICKER GA. AND DIFFERENT SPACING 6" LOAD BEARING MTL. STUD WALL; BATT INSULATION (FULL WIDTH) R-21; 5/8" GYP. BD. ONE SIDE; 5/8" GLASS-MAT GYPSUM SHEATHING BOARD; REF. S-SERIES DRAWINGS FOR STUD TYPE, SPACING, AND GAUGE 6" MTL. STUD WALL; @16" O.C. 5/8" GLASS-MAT GYPSUM SHEATHING BOARD ONE SIDE; REF. S-SERIES DWGS. FOR MTL. STUD GAUGE 8" MTL. STUD WALL; @16" O.C. UNLESS NOTED OTHERWISE 5/8" GYP. BD. ONE SIDE; 5/8" GLASS-MAT GYPSUM SHEATHING BOARD ONE SIDE; REF. S-SERIES DWGS FOR MTL, STUD GAUGE 8" MTL. STUD WALL; @16" O.C. UNLESS NOTED OTHERWISE BATT INSULATION (FULL WIDTH) R-21 5/8" GYP. BD. ONE SIDE; 5/8" GLASS-MAT GYPSUM SHEATHING BOARD ONE SIDE; REF. S-SERIES DWGS FOR MTL, STUD GAUGE 9 1/4"45-49U4651 6 5/8" 6" MTL. STUD WALL; @16" O.C. UNLESS NOTED OTHERWISE BATT INSULATION (FULL WIDTH) R-21; 5/8" GLASS-MAT GYPSUM SHEATHING BOARD ONE SIDE; REF. S-SERIES DWGS FOR MTL, STUD GAUGE 45-49U4651 11 3/4"45-49U4353 8" MTL. STUD WALL; @16" O.C. UNLESS NOTED OTHERWISE 5/8" GLASS-MAT GYPSUM SHEATHING BOARD ONE SIDE; REF. S-SERIES DWGS FOR MTL, STUD GAUGE 8" MTL. STUD WALL; @ 16" O.C. UNLESS NOTED OTHERWISE BATT INSULATION (FULL WIDTH) R-21; 3 LAYERS 5/8" GYP. BD. ONE SIDE; 3 LAYERS 5/8" GYP. BD. ONE SIDE; REF. S-SERIES DRAWINGS FOR STUD TYPE, SPACING, AND GAUGE WALL LEGEND BRIEF DESCRIPTION FIRE RATING UL LISTING STC RATING THICKNESS 2 OR 1 HOUR TABLE 721.1 (2) ITEM 4-1.1 PLAN VIEW SECTION VIEW 08.21.2015 08.21.2015