Loading...
HomeMy WebLinkAboutChaucie's Place DrawingsMA Y 2 0 1 6 CH A U C I E ’ S P L A C E N SI T E P L A N SC A L E : 1 / 3 2 ” = 1 ’ - 0 ” 1. 2163 sf of grass pavers added : provides about 10 additional parking spaces.2. remove existing crushed stone and replace with grass pavers. 3. dotted lines indicate existing patio and landscaping to be removed.4. existing building roof structure 5. proposed building addition roof structure. 1 1 10 6 t h s t r e e t 2 3 5 4 DE C E M B E R 2 0 1 5 CH A U C I E ’ S P L A C E N EX I S T I N G F L O O R P L A N SC A L E : 1 / 8 ” = 1 ’ - 0 ” ST O . ST O . STO.STO.STO.RR RR EN T R Y PL A Y R O O M ST O . ME E T I N G RO O M KI T C H E N PA T I O CO N F E R E N C E RO O M OFFICEOFFICE OFFICE DE C E M B E R 2 0 1 5 CH A U C I E ’ S P L A C E N PR O P O S E D F L O O R P L A N - P H A S E 1 : 1 1 - 1 2 D E S K S SC A L E : 1 / 8 ” = 1 ’ - 0 ” 793 sf total addition 790 sf total renovation 3354 gsf total building OFFICE 2OFFICE 3 HA L L ST O . RR ST O . WA I T I N G RO O M KI T C H E N / BR E A K R O O M OF F I C E 5 CO P Y / ST O . TH E R A P Y EXISTING OFFIICE EXISTING OFFIICE 2 OF F I C E 4 EX I S T I N G RR EN T R Y AD A R A M P OF F I C E 1 MU L T I - P U R P O S E R O O M 59 2 n e t s f existing walls new walls unaffected areas affected areas 1 2 5 3 4 DE C E M B E R 2 0 1 5 CH A U C I E ’ S P L A C E N PR O P O S E D F L O O R P L A N - P H A S E 2 : 1 3 + D E S K S SC A L E : 1 / 8 ” = 1 ’ - 0 ” 790 sf addition 530 sf renovation OFFICE 2OFFICE 3HALL ST O . RR ST O . WA I T I N G RO O M KI T C H E N OF F I C E 5 TH E R A P Y EXISTING OFFIICE EX I S T I N G OF F I I C E EXISTING OFFIICE OF F I C E 4 EX I S T I N G RR EN T R Y AD A R A M P OF F I C E 1 MU L T I - P U R P O S E R O O M existing walls new walls 5unaffected areas affected areas 1 2 5 3 4 DE C E M B E R 2 0 1 5 CH A U C I E ’ S P L A C E N OV E R A L L E L E V A T I O N S SC A L E : 1 / 8 ” = 1 ’ - 0 ” SOUTH ELEVATION1 NORTH ELEVATION20’-0”FINISH FLOOR 0’-0”FINISH FLOORMATCH EXISTING SOFFIT HEIGHT EXISTING SOFFIT HEIGHTMATCH EXISTING ROOF HEIGHT MATCH EXISTING ROOF HEIGHTEXISTINGROOF HEIGHTEXISTINGROOF HEIGHT DE C E M B E R 2 0 1 5 CH A U C I E ’ S P L A C E N EL E V A T I O N S & S E C T I O N S SC A L E : 1 / 8 ” = 1 ’ - 0 ” EAST ELEVATION3 WEST ELEVATION / SECTION4 ELEVATION / SECTION5NORTH0’-0”FINISH FLOOR 0’-0”FINISH FLOOR 0’-0”FINISH FLOORMATCH EXISTING SOFFIT HEIGHT MATCH EXISTING SOFFIT HEIGHT MATCH EXISTING SOFFIT HEIGHTMATCH EXISTING ROOF HEIGHT 10’-9”T/O NEW ROOFEXISTINGROOF HEIGHT DE C E M B E R 2 0 1 5 CH A U C I E ’ S P L A C E N PE R S P E C T I V E 1 SC A L E : N T S DE C E M B E R 2 0 1 5 CH A U C I E ’ S P L A C E N PE R S P E C T I V E 2 SC A L E : N T S DE C E M B E R 2 0 1 5 CH A U C I E ’ S P L A C E N PE R S P E C T I V E 3 SC A L E : N T S