Loading...
HomeMy WebLinkAbout259069 05/31/16 CITY OF CARMEL, INDIANA VENDOR: 370617 J® j ONE CIVIC SQUARE INDUSTRIAL PRODUCTS CORPORATIOPCHECK AMOUNT: $*****6,735.68* CARMEL, INDIANA 46032 119 S SHERRIN AV. CHECK NUMBER: 259069 SUITE 120 CHECK DATE: 05/31/16 LOUISVILLE KY 40207 DEPARTMENT ACCOUNT PO NUMBER INVOICE NUMBER AMOUNT DESCRIPTION 652 5023990 16-2046 6,735.68 OTHER EXPENSES VOUCHER # 165354 WARRANT# ALLOWED 370617 IN SUM OF $ INDUSTRIAL PRODUCTS CORPORATI 119 S.SHERRIN AVE. LOUISVILLE, KY 40207 Carmel Wastewater Utility ON ACCOUNT OF APPROPRIATION FOR Board members PO# INV# ACCT# AMOUNT Audit Trail Code 16-2046 02-2308-00 $6,735.68 Depreciation Voucher Total $6,735.68 Cost distribution ledger classification if claim paid under vehicle highway fund Prescribed by State Board of Accounts City Form No.201 (Rev 1995) ACCOUNTS PAYABLE VOUCHER CITY OF CARMEL An invoice or bill to be properly itemized must show, kind of service, where performed, dates of service rendered, by whom, rates per day, number of units, price per unit, etc. Payee 370617 INDUSTRIAL PRODUCTS CORPORATION Purchase Order No. 119 S.SHERRIN AVE. Terms LOUISVILLE, KY 40207 Due Date 5/19/2016 Invoice Invoice Description Date Number (or note attached invoice(s) or bill(s)) Amount 5/19/2016 16-2046 $6,735.68 1 hereby certify that the attached invoice(s), or bill(s) is (are)true and correct and I have audited same in accordance with IC 5-11-10-1.6 Date Officer p�1,� INDUSTRIAL PRODUCTS CORPORATIONJAL Invoice 119 S. Sherrin AV. Suite 120 DATE INVOICE# Louisville, KY 40207 4/29/2016 16-2046 BILL TO SHIP TO City of Carmel WTP City of Carmel WTP Jeff Cooper Jeff Cooper 9609 Hazel Dell Pkwy. 9609 Hazel Dell Pkwy. Indianapolis,IN 46280 Indianapolis,IN 46280 P.O. NUMBER TERMS REP SHIP VIA F.O.B. 516008 Credit Card DPL 5/6/2016 UPS Factory QTY ITEM CODE DESCRIPTION PRICE EA... Back Order Qty. AMOUNT 2 01-2613-20 03 Ozone Transmitter,Model TA-2100, 1,695.00 0 3,390.00 Mil-Ram patented electrochemical diffusion type sensor.3 or 4-Wire.Operating Voltage: 12 VDC(or 15-30VDC)Power Req: 1.08W at 24 VDC,2.60 W max. w/relays. Detection Range:0.0-20.0 ppm.Resolution:0.1 ppm.Output: 4-20mA,linear.Self-Calibration, non-intrusive Auto Calibration with magnet.LCD display, 12 characters x 2 lines.Indicates Peak Value,15 minute TWA(time-weighted average),Days since last gas calibration, Remaining Sensor Life(months),and continuous diagnostics.Enclosure: copper-free aluminum,epoxy painted, explosion-proof,rated Class 1,GR B,C,D. Thank you for your order! Sales Tax Total Balance Due Phone# Fax# E-mail Web Site 5022222401 502/222-2408 dlambert@ipcprotects.com www.ipcprotects.com Page 1 f INDUSTRIAL PRODUCTS CORPORATION Invoice 119 S. Sherrin Av. Suite 120 DATE INVOICE# Louisville, KY 40207 4/29/2016 16-2046 BILL TO SHIP TO City of Cannel WTP City of Carmel WTP Jeff Cooper Jeff Cooper 9609 Hazel Dell Pkwy. 9609 Hazel Dell Pkwy. Indianapolis,IN 46280 Indianapolis,IN 46280 P.O. NUMBER TERMS REP SHIP VIA F.O.B. 516008 Credit Card DPL 5/6/2016 UPS Factory QTY ITEM CODE DESCRIPTION PRICE EA... Back Order Qty. AMOUNT 1 27-DC24XP000B Pump Sampling Module for TA-2100 1,295.00 0 1,295.00 Toxic Transmitters.Provides sample draw capability to smarter Transmitter. Includes sample pump and flow switch. Enclosure:explosion-proof,rated Cl I GR B,C,D.Flow fault condition acknowledged at transmitter.Power Requirement:24VDC,0.10 amps. 1 13-0000 Filter,0.20UM,50MM,Hydrophobic 20.00 0 20.00 1 13-2013 Filter,Coalescing with Twist Drain 150.00 0 150.00 Thank you for your order! Sales Tax Total Balance Due Phone# Fax# E-mail Web Site 5022222401 502/222-2408 dlambert@ipcprotects.com www.ipcprotects.com Page 2 INDUSTRIAL PRODUCTS CORPORATION Invoice AL 119 S. Shemin Av. JawSuite 120 DATE INVOICE# Louisville, KY 40207 4/29/2016 16-2046 BILL TO SHIP TO City of Carmel WT? City of Cannel WTP Jeff'Cooper Jeff Cooper 9609 Hazel Dell Pkwy. 9609 Hazel Dell Pkwy. Indianapolis,IN 46280 Indianapolis,IN 46280 P.O. NUMBER TERMS REP SHIP VIA F.O.B. S16008 Credit Card DPL 5/6/2016 UPS Factory QTY ITEM CODE DESCRIPTION PRICE EA... Back Order Qty. AMOUNT 1 01-2002 TA-2002 Dual Channel Controller, 1,795.00 0 1,795.00 microprocessor based,front panel programmable, 16 character x 2 line backlit LCD Display. Alarm relays: Low,Mid,High and Fault, programmable latching/non-latching, energized/non-energized,0-255 sec. time delay,alarm on increasing or decreasing. 85-264 VAC powered. Output: 4-20 mA,4 relays with SPST contacts, 12 A,28 VDC/12A,120 VAC resistive.Wall mount enclosure, polycarbonate NEMA 4X,71/2"W X 9 5/8"H X 4 3/4"D Chg Shipping charges 85.68 85.68 Thank you for your order! Sales Tax $0.00 Total $6,735.68 Balance Due $6,735.68 Phone# Fax# E-mail Web Site 5022222401 502/222-2408 dlambert@ipcprotects.com www.ipcprotects.com Page 3 INDUSTRIAL PRODUCTS CORPORATION packing Slip 119 S. Sherrin Av. Suite 120 DATE INVOICE# Louisville, KY 40207 4/29/2016 16-2046 BILL TO SHIP TO City of Carmel WTP City of Carmel WTP Jeff Cooper Jeff Cooper 9609 Hazel Dell Pkwy. 9609 Hazel Dell Pkwy. Indianapolis,IN 46280 Indianapolis,IN 46280 P.O. NUMBER TERMS REP SHIP VIA F.O.B. S16008 Credit Card DPL 5/6/2016 UPS Factory QUAN... ITEM CODE DESCRIPTION 2 01-2613-20 03 Ozone Transmitter,Model TA-2100,Mil-Ram patented electrochemical diffusion type sensor.3 or 4-Wire.Operating Voltage: 12 VDC(or 15-30VDC)Power Req: 1.08W at 24 VDC,2.60 W max.w/relays. Detection Range:0.0-20.0 ppm. Resolution:0.1 ppm.Output:4-20mA,linear.Self-Calibration,non-intrusive Auto Calibration with magnet.LCD display, 12 characters x 2 lines.Indicates Peak Value, 15 minute TWA(time-weighted average),Days since last gas calibration, Remaining Sensor Life(months),and continuous diagnostics.Enclosure: copper-free aluminum,epoxy painted,explosion-proof,rated Class I,GR B,C,D. 1 27-DC24XP000B Pump Sampling Module for TA-2100 Toxic Transmitters.Provides sample draw capability to smarter Transmitter.Includes sample pump and flow switch. Enclosure:explosion-proof,rated Cl I GR B,C,D.Flow fault condition acknowledged at transmitter.Power Requirement:24VDC,0.10 amps. 1 13-0000 Filter,0.20UM,50MM,Hydrophobic 1 13-2013 Filter,Coalescing with Twist Drain 1 01-2002 TA-2002 Dual Channel Controller,microprocessor based,front panel programmable, 16 character x 2 line backlit LCD Display. Alarm relays:Low, Mid,High and Fault,programmable latching/non-latching, energized/non-energized,0-255 sec.time delay,alarm on increasing or decreasing. 85-264 VAC powered.Output: 4-20 mA,4 relays with SPST contacts, 12 A,28 VDC/12A, 120 VAC resistive.Wall mount enclosure,polycarbonate NEMA 4X, 71/2"W X 9 5/8"H X 4 3/4"D Chg Shipping charges Thank you for your order! Phone# Fax# E-mail Web Site 5022222401 502/222-2408 dlambert@ipcprotects.com www.ipcprotects.com