HomeMy WebLinkAbout16050103 Building PlansGENERAL INFORMATION / COVER SHEET BUILDING SITE PLAN FLOOR PLAN / REFLECTED CEILING FIXTURE PLAN / DETAILS ARCHITECTURAL DRAWINGS: G1.0 SP1 A1.0 A1.1 OCCUPANCY: - CLASSIFICATION(S): - EXISTING SHELL BUILDING: EXISTING TO REMAIN - PROPOSED PROJECT: B (INTERIOR REMODEL) CONSTRUCTON: - CLASSIFICATION(S): II-B SQUARE FOOTAGE: - 19,731 SF = TOTAL EXISTING BUILDING - 1,152 S.F. = TOTAL AREA INTERIOR REMODEL SPRINKLER: - YES OCCUPANCT LOAD: - 02 OCCUPANTS =RETAIL (120 SF / 100 = 2) - 04 OCCUPANTS = WOORKROOM / STORAGE (1,032 SF / 300 = 4) EXITS: - 1 REQUIRED > 50 OCCUPANTS (PER TABLE 1015.1, 2006 IBC) ALLOWABLE EXIT TRAVEL DISTANCE: - 200 FT = "B" OCCUPANCY - TABLE 1016.1 PROJECT NOTES: 01. EXISTING "STRIP CENTER" SHELL BUILDING TO REMAIN AS IS WITH NO EXTERIOR WORK BEING PERFORMED AS PART OF THIS PROJECT. REMODELED AREA OCCUPANCY TYPE IS ALLOWABLE PER ORIGINAL BUILDING OCCUPANCY TYPE. 02. NEW TENANT TO BE CONFIGURED AS SHOWN. NO CHANGES TO EXISTING DEMISING WALLS IN THIS PROJECT. NO CHANGES TO OTHER EXISTING TENANTS TO REMAIN AS IS. 03. NEW TENANT IS UTILIZING EXISTING HVAC, PLUMBING, POWER SYSTEMS, LAYOUTS, SIZES, EQUIPMENT, ETC. AS IS UNLESS NOTED OTHERWISE IN THESE DRAWINGS. 04. NO COMCHECK REPORT REQUIRED FOR ARCHITECTURAL WORK PER SECTION 12 OF GENERAL ADMINISTRATIVE RULES (675 IAC 12-4-12 EXISTING BUILDINGS, ADDITIONS & ALTERATIONS. HVAC PLAN WATER & SEWER PLAN PLUMBING ISOMETRIC & DETAILS POWER PLAN LIGHTING PLAN POWER SCHEMATIC ELECTRICAL - MECHANICAL - PLUMBING DRAWINGS: M1.0 E1.0 ar c h i t e c t u r e sp a c e p l a n n i n g in t e r i o r d e s i g n 31 7 . 8 7 3 . 9 2 6 6 16 3 7 c o r n i c h e d r i v e zi o n s v i l l e i n 4 6 0 7 7 te l e p h o n e ( ) 100 1,419 SF AVAILABLE 105 1,445 SF AVAILABLE 110 1,152 SF CLASSIC CLEANERS 115 1,966 SF AVAILABLE 120 1,560 SF AVAILABLE 125 1,560 SF AVAILABLE 130 1,671 SF AVAILABLE 135/140 2,918 SF AVAILABLE 145 2,336 SF AVAILABLE 150 1,845 SF AVAILABLE 155 1,859 SF AVAILABLE ADMINISTRATOR RULES - 675 IAC 12 BUILDING CODE - 2014 INTERNATIONAL BUILDING CODE - INDIANA AMENDMENTS 675 IAC 13-2.6 HANDICAP ACCESSIBILITY CODE 2014 INDIANA BUILDING CODE CHAPTER 11 - 675 IAC 13-2.6-12 CHAPTER 11 - A117.1 ACCESSIBILITY AND USABLE BUILDINGS AND FACILITIES 2009 EDITION ELECTRICAL CODE 2009 INDIANA ELECTRICAL CODE (IEC) - 2008 NFPA 70 - 675 IAC 17-1.8 PLUMBING CODE 2012 INDIANA PLUMBING CODE (IPC) - 675 IAC 17-1.8 FIRE CODE 2014 INDIANA FIRE CODE - 2012 INTERNATIONAL FIRE CODE - 675 IAC 22-2.5 MECHANICAL CODE 2014 INDIANA MECHANICAL CODE (IMC) - 2012 INTERNATIONAL MECHANICAL CODE - 675 IAC 18-1.6 ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE (IECC) - ASHRAE 90.1, 2007 EDITION - 675 IAC ARTICLE 19.3 STRUCTURAL CODE 2008 INDIANA BUILDING CODE - 2012 IBC - INDIANA AMENDMENTS INDUSTRIALIZED BUILDING CODE - 675 IAC15-1 ELEVATOR SAFETY CODE 2011 INDIANA ELEVATOR SAFETY CODE - 675 IAC 21 BUILDING REHABILITATION STANDARD INDIANA BUILDING REHABILITATION STANDARD (GAR) - 675 IAC 12-8 FUEL GAS CODE 2012 INTERNATIONAL FUEL GAS CODE 2014 INDIANA FUEL GAS CODE - 675 IAC 25-3 RESIDENTIAL CODE 2005 INDIANA RESIDENTIAL CODE 2003 INTERNATIONAL RESIDENTIAL CODE FOR ON AND TWO FAMILY DWELLINGS CHAPTER 43 OF THE 2006 INTERNATIONAL EXPEDIENTIAL CODE FOR ONE AND TWO FAMILY DWELLINGS - 675 IAC 14-4.3 CHAPTER 11 OF THE 2009 INTERNATIONAL RESIDENTIAL CODE - 675IAC 14-43-139.1 MOBILE STRUCTURE CODE INDIANA MOBILE STRUCTURE CODE - 675 IAC 15-2 SANITARY CODE 1998 AMERICAN SOCIETY OF SANITARY ENGINEERS STANDARD 1051 - 675 IAC 16-2 SWIMMING POOL CODE - 675 IAC 20-1.1 AMUSEMENT DEVICE CODE - 675 IAC ARTICLE 23-1 MIGRANT DAY/NURSERY FIRE SAFETY CODE - 675 IAC ARTICLE 24-1