HomeMy WebLinkAbout16080071 Site Plan• � • • �
� � � � �
� � �
' � • - • - • • • - !1 � - - � , , � � ,
• . .
LAKE IPORTER
Boone
NEWTON
.
. • � . . • • . • •
/ LAPORTE ST.JOSEPH
MARSNALL
STARKE
PULASKI FULTON
WHITE CASS
BENTON CARROL
TIPPECANOE
WARREN
FOUNTAIN � MONTGOMERY
o PARKE �
J
J
�
�
w
>
VIGO CLAY
SULLIVAN
GREENE
CLINTON
ELKHART LAGRANGE STEUBEN
NOBLE DEKALB
KOSCIUSKO
WHITLEY ALLEN
WABASH HUNTINGTON
MIAMI
WELLS ADAMS
GRANT
HOWARD
BLACK- � �AY
FORD
TIPTON MADISON DE�AWARE
RANDOLPH
HAMILTON S I `V
Hamilton
Hamilton
PUTNAM HENDRICKS
MORGAN �OHNSON
OWEN
RUSH UNION
FAYETTE
Hamilton
SHELBY DECATUR
MONROE BROWN BARTHOLOMEW
RIPLEY DEARBORN
_ JENNWGS (
LAWRENCE
KNOX MARTIN
DAVIESS
ORANGE
PIKE DUBOIS
GIBSON CRAWFORD
POSEY WARRICK
VANDER-
BURGH
SPENCER
�:�'1
JACKSON
WASHINGTON SCOTT I
CLARK
HARRISON
FLOYD
DESCRIPTION OF REAL ESTATE: TRACT ONE - EDGERTON PROPERTY
PART OF THE NORTHWEST QUARTER OF SECTION 31, TOWNSHIP 18 NORTH, RANGE 3 EAST IN
CLAY TOWNSHIP, HAMILTON COUNTY, INDIANA BEING DESCRIBED AS FOL�OWS:
COMMENCING AT THE SOUTHWEST CORNER OF THE NORTHWEST QUARTER OF SECTION 31,
TOWNSHIP 18 NORTH, RANGE 3 EAST; THENCE ON THE SOUTH �INE OF SAID NORTHWEST
QUARTER NORTH 90 DEGREES 00 MINUTES 00 SECONDS EAST 1326.33 FEET (ASSUMED
BEARING) TO THE SOUTHEAST CORNER OF A TRACT OF REAL ESTATE DESCRIBED IN
INSTRUMENT NUMBER 20060015249; THENCE ON THE EAST LINE OF THE WEST HA�F OF THE
NORTHWEST QUARTER OF SAID SECTION 31 NORTH 00 DEGREES 04 MINUTES 44 SECONDS
EAST 1115.80 FEET TO THE POINT OF BEGINNING;
THENCE CONTINUING ON SAID EAST LINE OF NORTH 00 DEGREES 04 MINUTES 44 SECONDS
EAST 208.00 FEET TO THE NORTHEAST CORNER OF A TRACT OF REAL ESTATE DESCRIBED IN
DEED BOOK 337 PAGE 148; THENCE SOUTH 90 DEGREES 00 MINUTES 00 SECONDS WEST 589.85
FEET TO THE NORTHWEST CORNER OF SAID TRACT OF REAL ESTATE; THENCE SOUTH 00
DEGREES 04 MINUTES 44 SECONDS WEST 208.00 FEET; THENCE NORTH 90 DEGREES 00
MINUTES 00 SECONDS EAST 589.85 FEET TO THE POINT OF BEGINNING, CONTAINING 2.82
ACRES MORE OR LESS.
OH�� C
JEFFERSON SWITZERLAND
� ' ' �
.
•• � • i •
S�EET I�DE�
�
Title Sheet
Sanitary Plan
S�nitary Details
♦��. � ♦ � .. �
12250 West Road
Zionsville, IN 460%7
_' .'' 1• 11 11 1 i 1
� � • � � � � � � �
�
�. -. -�., , . � -�
. • •
NOTE #1 NO CONSTRUCTION TRAFFIC ALLOWED ON AREA OF THE MOUND OR
PERIMETER DRAIN, THE AREA IS TO BE FENCED WITH ORANGE SNOW FENCE.
NOTE #2 A�� OPENINGS AND SURFACES OF SEPTIC TANK TO BE SEALED TO PREVENT
GROUNDWATER LEAKAGE INTO SYSTEM.
NOTE #3 A�L SUBSURFACE DRAINS SHA�L HAVE A MINIMUM TRENCH WIDTH OF 12" AND
SHA�� BE BACKFIL�ED TO A DEPTH OF 24" OVER THE TOP OF THE PIPE, WITH
EITHER PEA-GRAVE� OR #7 AGGREGATE. (SEE SHEET C300 FOR PERIMETER
DRAIN DETAIL)
NOTE #4 SAND OR SAND MIXTURES ARE NOT PERMITTED FOR BACKFILL.
NOTE #5 FINISH F�OOR ELEVATION IS TO BE 6 FEET ABOVE THE PROPOSED FINISHED
GRADE. THIS DIMENSION MAY VARY IN ORDER TO BE IN ACCORDANCE WITH
THE PLANS AND SPECIFICATIONS OF THE PROPOSED STRUCTURE.
CO�SULTA�T
�����tt
�� ��,,,t � � ��� ( �
�1,
�
��f �,.�, �
� ��l�b,; �
_
����s��� ,
��t
..� � i. � -- .� -� �.�
' • � i //// . • � i /�••
. • �.•�' ' • i
'• �.•�� � • �
• �
.
- . • ' -- ••- •
i� � �•.•
� � � • �
•• • 11
• '� �'
G & R Excavating, Inc.
Austin Williams
1611 W. 236th Street
Sheridan, I N 46069
Ph:(317) 758-4846
���+»", ��,�r��s
.A��S� �N �� �-9�~.
. \ 4,, `
�,�v�Q� a��,���sT£RFo y � =:
_ N�. P � _
: 910326 :
. . % �° �� STATE OF " � �
` • o�.t�`'=.. � `� �":
� HDIANP�°°'���'��
Christian C. Badger, P.E. 10326 �'.,FS'9�``•s��s�rd�•= C� �•
Dated: 04/25/2016 �'�d,�`��4NAl. `��a���
FLOOD HAZARD STATEMENT:
No portion of the described tract of land lies within a Flood Nazard Zone as
scaled on Community Number 18057, Panel Number 205 of 300. Map
Number 18057CO205G of the Flood Insurance Rate Maps for Hamilton
County, Indiana maps dated November 19, 2015. The accuracy of any
flood hazard data shown on this project is subject to the map scale
uncer�ainty and to any other uncertainty in location or elevation on the
referenced Flood Insurance Map.
,--,-.__
/
/
/
36.5' 0� 4" P F
�--,, P I P E@ 1. 0 0 � g 0° � �' � �"�%
.�� -,_-,,,,,,, _..� gp6 ��► v 4" e r f o� F�, _� 5 8 9. 8 5'
pipe=902.53 ,� So,� FM
� o BORICNG \ 136' OF 2" PVC
DISTRIBUTION BOX �, # �,�
o-gox �
��
GR.EL. = 909.78 FT � .�i� ,�� (�1 V 4'� p erf
. , t.n I�
FM. EL. = 906.20 FT Y. #� �' �' pipe=902.1 3 .�� c� o�
PIPE EL. = 906.12 FT � • • •
/ � 6� N N c
�` rn o o c
,90 9 4' 0 F 4" P E R� �o �., " o°i�� � o� �� c
5�---- PIPE @ 0.30� � � �5 94' 0� 4" PER� �3 > > > :
� PIPE @ 0.53� �`� z z z:
� �..___ -----,.
� ����� �� : �� I�I�I�TRATOR AT� �M ,3,,
�- ��, � � �00�/ E�EVATED SYST M ❑ o 0 0
EXISTING
HOME
�
�
�..w �.24.0�� � �. � n �
� - �I \
� ��
� W � � / °
� �. 2�8� Ac� � o
�o � O o 3+43.60 - W " �00
o� � � - + � 0
� � � "' 0 17-09-31-00-00-028.107 ---_. � _
� � � M / o :-----'._
� � � � � �� o �
.....�.24:� � _ � �. ... /
_/ �
- N 40.9 '-------
/:
�\ I�1V 4" perf o°`� (SEE DETAI�S) o� � o
``� 9 p i p e= 9 01. 8 3 �i' _ Bo�,�- � c�i �- � ��, -- 9� 7 �O� \ oo � o
� c�� 1000 GA �ON HO �, 3 T �--��
� �3 N f- o o-------o �� �X � �
o � D0SI�1G aN� FFE=9�0.55' �Ew 4 9 ;, � p
� � � � � I �
o� 0 1000 GA��ON WE�� , . � 9 ..
� � � �`` � o � � FBE= 00.50' -�''-- � X ° o " ..
� 36.5 0� 4 PER� �! S� SEP IC TANI� � Q_ �(� �� ---�
0 P I P E@ . 5 5� �V BORING 2 6' 0 F� 4" P VC >� R -�-----" -- �
� #� � 0.94' l
. / .
" PIP @ 1.33% - � 9 � �
I�1 V 4 e r f ��. ����, �
O
N
�� � � �
� � m�
j � � � _____-- o
� pipe=901.63' � __ ��� _ o
��� � o 0
--� � �� �� �:� �� 2+00� � _
So�� � � �� � ���� � ;� �
BORING /
\ #2 � :
� � o
o j ,, 9 � OO
� / � w ` � 2 `�� � ; Luke and Ashle��dgerton
�.. � � o�
\ � � 1 �
% � 12280 st Road
,,� 9os
�/ � 9 99
,�� 139 0� 4 SO�ID PIPE @ �.30�
� \ � ��� le, I N 46077
W -�-- � 6'
��� � NDERGROUND 317) 691-6100
�"�f 903- ELEC IRT C SERVICE o
`w SII�G�E PN\��E, 000�
/ � � 40 0 WA TTS ---�.. �
/ �.-- o00 -
\ / � o00
� �- � � o �� �oo
� �/ -_� o0
� o
-----" _,,,_,_.--- o 0 0 0 0 0 0 0 0 0 0---�'" °o
�'\ �/' �- o00 000
�_ /,. o�° r� �� TO E X I S TI I�l G C'
�- o-�'� f E�ECTRIC � �
--_..
S90°00'00"E 18.82' oo°...----''Ngo�o��o��� , W „ TRA1�IS�ORMER / N90°00'00"W � \��
N90 0�00 W
O/ � o°° 589.8�J� � 15 14'� � 5�,
15' DRAINAGE EASEMENT ,� /� / / POB EASEMENT � � ��-
,--- - o / � � 1 1 0
/ �
� / ^ 0 15 ELECTRI EASEMENT ' �
. / / � oo � /
/ /
� / �`� / W �
- � �� h
�,� � � _----- - �- --_..,_.- oo° � � o
� r \ �____ �
, o� � � / o / 1 � /_
028� 006 0 � s � � � --� �° / � �' / / ---
�, �� o �� 902 oa� .
� /� o / 0 10 20
\ 2.0 Ac. /� ,o oo� � '� � ��� ��� . »_ ,
- 31- 0- 0 0- 0 2 8. � �� � ���� ��/ ° / SCALE. 1 20
� � � O
/ / �� �o �
/ /� ,--- �
� / f ���1 , 4„ � o�°
90, / / / 12 0� -S_Oo ID PIPEoo 0 30 0_� /
�_ / ______- 000 000
000 /�
� 000 O O �� (
p0� / ------�
� 99 9 �
0�51°42'35"W 15.0 ' Inv. 4 solid pipe; elev.=900.90 �
�° � 1/4 ton riprap and place an an�
�� guard at exit to pipe. Make�ure riprap
"/ is below or out of channels normal
\
/ / flow. � �
Know what's belOW.
C1II before you dig.
�EGEN D
h
x�h�2 EKISTING SPOT ELEV. ,,-�'� SUBSURFACE DRAIN
(too.00 Ec.) EXISTING GRADE /oo° �FLOW LINE
tot.5o PROPOSED ELEIiATION (FFE) FINISHED FLOOR ELEI/ATION
�5O- EXISTING CONTOUR � UTILITY POLE
� DRAINAGE FLOW SOII TEST
�.Ec. MAiCH EXISTING GRADE
EXISTING LARGE TREE O TEMPORARY BENCHMARK
CAUTION:
LOCATIONS OF AL� EXISTING 11NDERGROUND 11Ti�ITIES SHOWN
ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE
(INC�UDING, BUT NOT LIMITED T0, MANHOLES, IN�ETS, VALVES,
AND MARKS MADE UPON TNE GROUND BY OTNERS) AND ARE
SPECl1LATIVE IN NATURE. THERE MAY ALSO BE OTNER EXISTING
UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE
GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE
WAS OBSERVED. THE EXACT �OCATIONS OF SAID EXISTING
UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE
CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION.
OWNER
Luke and Ashlee Edgerton
12280 West Road
Zionsville, IN 46077
(317) 691-6100
• � ! � i � � � �
Gravity Sewer
PVC ASTM-D 2665 for 4-inch and 6-inch pipe only
PVC ASTM-F 891 SDR 35 for 4-inch through 8-inch cellular core pipe with
minnimum pipe stiffness of 50 (PS 50)
PVC ASTM-D 3034 SDR 35 for 4-inch pipe through 15-inch pipe
Pressure sewer, SDR 26, with compression fittings for special crossing
conditions with potable water lines
Force Main
Any PVC or ABS pipe listed below for potable water or else PVC ASTM-D 1785
Schedule 40, 80, or 120
Compression fittings must be used in crossing situations with potable water
lines
Potable Water
The water must have the NS� (National Sanitation Foundation) seal for potable
water and be rated to withstand the applied pressure.
Solevant-weld fittings are not acceptable.
PO�YETHYLENE 160 p.s.i. SDR 7 in 3/4-inch, 1 inch, and 1 1/4-inch diameters only.
PVC ASTM-D 2241 SDR 13.5, 17, 21, or 26
ABS ASTM-D 1527 Schedule 40, 80
ASTM-D 2282 SDR 13.5, 17, 21, or 26
1/3 HP - MAX. SOLIDS 1/2" SPHERE - 1550 RPM
AMPS AT 1 sn 1 15 V. OR 230V.
40
w
� 30
z
0 20
w
_
Q 10
�
0
�
� � � � � � � ,� �
0 10 20 30 40 50 60
U.S. GALLONS PER MINUTE
35.1 gpm = 0.0782 cfs
(153.2 gallons per 4.36 minutes with a total head of 13.28')
PUMP DISCI�ARGE CURVE
HYDROMATIC SW33
N�T T� SCALE
,��»�e�r r � e t�,,,r j�
.+'`lS�� PN �' �9g$�`.
CONTRACTOR �`v�Q-�4�t�,G�sTERF� �G'�`'�6 No. Date Revision
G& R Excavating, Inc. .. N�. .. 1. 4 15 16 Submittal to Hamilton Co.
Austin Williams : " 910326 �: 2. 5 4 16 Well �ocation/Septic Tank 1000 gal
1611 W. 236th Street . %� m" STATE OF :: � W�
Sheridan, IN 46069 . ������.. ,�� 3. 5 20 16 Hamiltion Co. Revisions
r'� `�"���HDIAN P�a'`����:� 4. 5 30 16 Chan e to Future Gara e
Ph:(317) 758-4846 Christian C. Badger, P.E. 910326 ,•,�S'�``"•����6.a���° G�* g g
Dated: 04/25/16 �',,►„S�01VA� ���'�
�`I18iil�A���O
ENGINEERING
990 W. Oak Street
Zionville, IN 460��
(765) 485-0000
Towu of Z
Design
ccb
ELEVATION HEAD
Pump Inv. = 899.56'
Pipe Inv. = 906.20'
�H = 4.64 ft.
MINOR LOSSES HEAD
Minor Losses 2" Pipe Using 50 gpm
50 gpm = 0.1114005 cfs
K= 90° Bend (4) = 0.9(4) = 3.6
45° Bend (2) = 0.4(2) = 0.8
4.4
V= Q�A - 0.1114005 _ 5.11 ft/s
�7(2/12}Z
4
� KV2 4.4(5.11 ft/s) 2
h� 2g 2(32.2) - 1J8 ft.
FRICTION HEAD
Pi�e Losses
Modified Hazen-Williams Formula
10.5658 * L* Q1'85 L= 136 ft.
F 9P
h p4.87 * �1.85 D= 2" m
hF = 6.86 ft. C= 150
FRICTION HEAD
Total Head Req'd =0h+h�+hF = 4.64ft. + 1J8ft + 6.86ft.
Total Head = 13.28 ft.
� � ♦ ♦ •
DEVELOPMENT PLAN REPLATED TRACT-13
Edgerton Septic System
,snille, Cla Towushi , Hamilton Count , Indiana
3y Drawn By Checked By Approved F
bwp ccb
llate
April 25, 2016
Job No.
16-019
Scale 1 " = 20'
Sheet No. C200
�
4" INLET
INV=902,44
67.0'"
�5.0' �
i
l..
REINF❑RCED �
CONCRETE
TC=905�50
FINISH GRADE
MANN�LE w �� � A�".
��� ivi x
� 4.0��
��
r c
�� ` > s
� _�__ �_ .�O„'.D. �
a
LIQUID �EVE�
� CONCRETE IN�ET BAFF�E
I'u�-1�1.1�1��
•i
20° I,D, HDPE RISERS & LID ARE
WATERTIGHT� ADD TO HEIGHT
IN 6" INCREMENTS
C24" MAX, EARTH C�VER)
i/�/C�NCRETE P�UG W/HAND�E
Z 3/4" TNICK, MIN, 59 LB,
� M�IV.
� 4° DIA, HIGH
__ PRESSURE SEAL
� CIN�ET & ❑UT�ET)
. 0 11
4" ❑UTLET
INV=902,11
- -} ''�-6" DIA, E���UENT
� FI�TER WITH
r 52.0�� GAS DEFLECT�R
^ Cuse a Tuf-Tite Ef-6
`� or Approved Equal)
r> I I����
.2 . ., �, . �, �� ��.� „ . ��r � � ,� . . � .�, . ., . . , ,,.r
.., .<,��. �,%.. �.. o��� � �.;> ;
.�. ,�� ..,_� „ �.::. .> <::: o�� .,1. .,:: a ., ,_..
98.0"
NOTES:
1) A�� SNIP-LAP J�INTS, GRADE RINGS, &
INSPECTI❑N LIDS MUST BE SEALED WATERTIGNT
WITH CS-z02 BUTY� SEA�ANT,
2) SUPP�IERS INC�UDE MCCREARY C�NCRETE
1000 GALLON SEPTIC TANKS DETAIL
3/4' = 1'-0'
THE EFFLIJENT PUMP IS T� BE WIRED �N A
SEPARATE CIRCUIT THAN THE AUDI�/VISUAL ALARM
HIGH WATER ALARM
LIGHT AND H�RN
COPTI❑NAL INSTALLATIDN IN GARAGE)
DISC�NNECT FRICTION L�SS 3,01 FEET
ELEVATI�N HEAD 4,48 �EET
T�TAL DYNAMIC HEAD 7,49 FEET
ACCESS HATCH T� BE
LARGE EN❑UGH F�R PUMP
REM�VAL AND MAINTENANCE
POWER
CONDUI� �FINISH GRADE
SECONDARY
MANWAY
ACCESS
� �
i tµ
INV=902,07 �R�M �
SEPTIC TANK
67.0'� �
, ( �
�2.0' �R
i
�"
12" - 24" TY P .
-4.0��
1, ., ,
GUIDE RAILS -�
ALARM
901,18
FLOATS <TYP)�"
�N 900.18 �
153,2 GALL❑NS
7,5 inches
❑FF 89956 �
REQUIRED STORAGE
Daily Flow = 3* 150 gallon per day = 450 gallons
Minimum Dose 150 gallon per dose + drain back
Drain Back = 145' of 2" pvc pipe 'V'= 3.16 gal
Total volume required to store "Vt"= 153.16 gal
1000 c�al tank A=20.41 �al�in
Total Required depth of Storage = 7.5 inches
TC=905,z5
16" HT X 24" DIA, P�LY COMPOSITE
RISER CAST IN T�P W/ STAZNLESS
STEEL TAMPER PR��� SCREWS AND
24" DIAMETER FIBERGLASS GASKETED
�ID,
LIFTING
CHAIN
32.0�� MiN
' 145' ❑F 2" PVC - SDR-Zl
POWER ,`° CDRAIN BACK = 3,16 GAL)
CABLE � �
INV=902.43
-' T� AT� PIPE
' �NO
" CNECK
� VA�VE
HYDR❑MATIC SW33 PUMP
PUMP CAPACITY 55,5 G,P,M,
BREAK
`` AWAY
�' ��ANGES
3" REIN��RCED�� +� �� C❑NCRETE
� PEDESTAL
C�NCRETE J.O f <; ,� .� °� "' ,_.
T SUMP E�=898.06 `r � .� U ` `'
�
�,
a �" ' <_ � . �`' u � . �" � �;7 � �. ;�. `� .a "`r,-� 4 ' :, . °. f-" "� � � " .;. .a <r o „
� ......f - � � -
. ..:> . . :- ...a. ..:_. . . .> ..
� ' 98.0" �
NOTES:
1) ALL SNIP-LAP J❑INTS, GRADE RINGS, &
INSPECTI�N LIDS MUST BE SEALED WATERTIGHT
WITN CS-202 BUTY� SEA�ANT,
�) SUPPLIERS INCLUDE MCCREARY CONCRETE
3) GALLONS PER INCH = z0�41
1000 GALLUN DOSI�G TANK DETA.IL
N�T T❑ SCALE
. . �- �
. !' � ' • � �
EXISTING GRADE
�
EXISTING GRADE
GEOTEXTILE FABRIC REQUIRED
OVER STONE BACK FILL
6" TOP SOIL COVER + + + + + +
0 0 0 0 0 0 0 0 0 0 0 0
000000000000000000000000
00000000000000000000000
00000000000000000000000
00000000000000000000000 _
� °�°�°�°�°�°�°�°�°�°�°� - 42" MINIMUM
o°o°o°o°o°o°o°o°o°o°o
_ o00000000000000000000 -
o°o°o°o°o°o°o°o°o°o°o
1" DIA. WASHED PEA GRAVEL - o 0 0°0°0°0°0°0°0°0°
� °o°o°o°o°o°o°o°o°o° -
0000000000000000000
000000000
#7 AGGREGATE WASHED o00000000000000000
GRAVEL FOR INITIAL BACK FILL o°o°o°o°o°o°o°o°
00000000 000000000
000000 0000000
0 0 0 0 0 0 0
000000 000000 " PERF. PIPE
0 0 0 0 0 0
4" MIN.
4" PERFORATED DRAW TILE �
MINIMUM = PIPE DIA. + 12'�... ...�
NOTE: MINIMUM PIPE SLOPE 0.3%
PERIMETER DRAIN DETAIL
NOT TO SCALE
12" MIN.
SOIL MATERIAL COVER
SYSTEM SAND INSTAL�ATION
MAY USE P�YWOOD TO �
FORM RIGHT ANGLES
, 1� \ \ . ��,�
24" MIN.
904.97
ENTRY ELEVATION=906.03'±
/ 12" MIN.
7ft -
MINIMUM SEPARATION
TO RESTRICTIVE �AYER
PER CODE
APPROXIMATE EDGE OF SOI� COVER
INDOT SPEC. 23 SAND
12" MIN.
TYP.
12" MIN
�li . � , � TYP.
.�.
ATL SYSTEM BED SECTION
SCALE = 3/8'= 1'-0'
SYSTEM SAND
INSTALLED MAY USE
PLYWOOD TO FORM
RIGHT ANGLES S
77'-0„
AT� SYSTEM CONDUITS
�•�ill�ll►1
1
7'-2"±
INSPECTION PORT
� . � : • :•
•1.
STING GRADE
°°e
°°o
�
4° PVC PIPE BED ELEVATION = 904.97 ft ," '� �
(75' LONG EACH)
L O O P T Y P. A T L B A S A L S A N D B E D A R E A 5 0 4 s f t 7- �
PIPE E� _
SLOPE
906.03 ft
4�� PVC PIP
16'-6 i. 1�" MIN. i �OOP TYP.
�
� � , BED ELEV�TI4N = 904.88 ft '. �
SL E
� ' DOWNSLOPE. SAND EXTENSIQN � i
P
. . .. .. .. . ' .
� .� ' .. . . . ..:. � � ' ' . � . . . . . . .. . .
I . . ` , . �.� ' . . . . , ; : , . . . , . , .
I. , . . _ . . ,. .. � � ' .. . . , ' . '. ... . . . . � . � . . . . . ' , � , � . , , , � . , � , . , ' ' , . . . 'I
I - ,. I
L.- �..- � �.- � - � - - - - - - - - � � � _._. � - - - = - - - - - - - - - - - = - - - - � � �
ATL TOTA� BASA� AREA 1,206 sft INSPECTION PORT 9'-6"
12" MIN. I
�
OWNER
Luke and Ashlee Edgerton
12280 West Road
Zionsville, IN 46077
(317) 691-6100
CONTRACTOR
G & R Excavating, Inc.
Austin Wiliiams
1611 W. 236th Street
Sheridan, IN 46069
Ph:(317) 758-4846
EDGE OF SOIL COVER
ATL BED LAYOUT FOR ELEVATED SANDBED SYSTEM
SCA�E = 3/16'= 1'-0'
,,,�a,Nr � � � r��a���
.w`'S���'N .�a Bqj'�.
�' � !� sr . � `-,
� V���O�vG\ ERF�a'C� �s
: 910�26 :
:
. % �° �� STATE OF �� � R
. ; �0,�'a. � .,� �<v .`
�°�<;., HpI AHP.:> \ ��'
Christian C. Badger, P.E. 910326 �'so S°°°b�°��°`° V.*
Dated: 04/25/16 �°,ds��IVAI �'��'�
,4ji/AA�atio��0��
�
❑UTLET T❑
ABS�RPTI�N
FIELD
> INV=906,1Z'
GR�UND=907,78'±
DISTRIBUTI�N B�X
�" STYR�F�AM
INSULATI�N �N T�P
DRI�� 1/4" VENT �N
T❑P ❑F 90° BEND
-1 2" �M �R�M TANK
2"
NOTES
1) EXTEND SAND BED TO A�LOW FOR THE
DISTRIBUTION BOX TO BE NEXT TO ATL
SYSTEM CONDUITS.
2) OUTLETS MUST BE ALIGNED & LEVELED BE
SURE TO ASBUILT ELEVATIONS.
� FIELD VERIFY *
� � i � � � � '�
►� � _
SEPTIC SYSTEM NOTES FOR THREE BEDROOM
1. CONTRACTOR SHALL INSTALL A MINIMUM OF 1,206 SF. OF BASAL
AREA. USINIG THREE ROWS OF ATL CONDUIT THE MINIMUM SAND
BEDDING ARE FOR THE CONDUIT SNALL BE 504 SF. WITH A MINIMUM
INFILTRATOR ATL CONDUIT LENGTH OF 206 FEET. THE BED AREA
SHALL BE 72 FEET BY 7 FEET.
2. TNE CONDUITS SHALL BE SPACED 2 FEET ON CENTERS AND
INSTALLED PARRALLEL TO EXISTING SITE CONTOURS.
3. THE SAND BED WIL� BEGIN AT A DEPTH MINIMUM TO 6" BELOW
EXISTING GRADE.
4. THE SITE OF THE PROPOSED ABSORPTION FIELD MUST BE
PROTECTED FROM COMPACTING, GRADING AND FILLING PRIOR TO
SYSTEM INSTA�LATION OR THE SITE MAY BE RENDERED USE�ESS.
5. 4" PERIMETER DRAINS ARE TO SURROUND THE ABSORPTION FIE�D
ON AL� SIDES, SPACED AT �EAST 1 FEET FROM THE TOP SOIL
COVER.
6. PERIMETER DRAINS ARE REQUIRED. DEPTN IS MINIMUM OF 36" OR 2"
I N TO TI LL.
7. SEPTIC TANKS AND ABSORPTION FIELDS MAY BE CONSTRUCTED NO
CLOSER TNAN 10 FEET TO A PROPERTY LINE, DWELLING, OR
STRUCTURE. MAINTAIN A 50 FOOT SEPARATION FROM ANY PRIVATE
WATER SUPPLY WELL.
8. ALL OPENINGS AND SURFACES OF TNE SEPTIC TANK SHALL BE
SEALED TO PREVENT GROUNDWATER LEAKAGE INTO THE SYSTEM.
9. ALL CONSTRUCTION ACTIVITY ON THIS SITE BE PERFORMED IN
COMPLIANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER
SAFETY.
10. NO TRAFFIC STALL BE PERMITTED ON THE PORPOSED SEPTIC
ABSORPTION FIELD AREA.
11. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD
VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO HIS
PHASE OF WORK. THE CONTRACTOR SHALL NOTIFY IN WRITING THE
OWNER OR TNE ENGINEER OF ANY CHANGES, OMISSIONS, OR
ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS
STARTED OR RESUMED.
12. ADDITIONAL SOIL COVER TO BE PLACED ABOVE EXISTING GRADE
AFTER CONSTRUCTION TO PROVIDE A MINIMUM OF 12" OF S01�
ABOVE THE FI�TER FABRIC FOR FREEZE PROTECTION.
13. CONSTRUCTION OF SEPTIC SYSTEM SHA�� BE CONDUCTED ON�Y
WHEN SOILS ARE DRY.
14. ONLY TOPS01�, NOT CLAY MATERIAL, SHAL� BE PLACED OVER THE
ABSORPTION FIELD.
15. FINISH GRADE TO OBTAIN POSITIVE SURFACE DRAINAGE AWAY FROM
FIELD.
16. FOL�OWING INSTAL�ATION, BUT PRIOR TO BACKFILLING OF SEPTIC
FIELD TRENCHES, HAMILTON COUNTY HEALTH DEPARTMENT SHAL� BE
NOTIFIED FOR INSPECTION.