Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.1 - CONSTRUCTION _ FINISH PLANS.pdf
Project Number: Revisions: Drawn By Checked ByIssue Date Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: HA R R I S O N & M O B E R L Y , L L P Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - B l d g A 76 0 R a n g e l i n e R o a d , S u i t e 1 6 4 COPYRIGHT & OWNERSHIP OF DOCUMENTS State Release Set: 8/5/16 N PEDCOR DESIGN GROUP A1.1 CONSTRUCTION / FINISH PLANS CONSTRUCTION DOCUMENTS MC BR8/5/16 PLAZA LEVEL KEY PLAN N.T.S. THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2016 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 760 Rangeline Road F 3 A4.1 8 A4.1 7 A4.1 FP16 FP3 FP11 FP9 FP15 FP6 FP1 FP4 FP13 FP1 FP1 FP1 FP1FP10 FP1 FP14 FP2 FP1 FP8 FP7 FP5 FP12 106 104 105 102 103 11 0 11 1 11 2 11 3 10 7 10 1 REST ROOM 105 CONFERENCE ROOM 106 STORAGE 104 MECH ROOM 110 OFFICE 113 OFFICE 112 OFFICE 111 RECEPTION AREA 101 COPY/FILE ROOM 107 COFFEE BAR AREA 109 OPEN OFFICE 108 OFFICE 103 CONFERENCE ROOM 102 ENTRY ALCOVE 100 W2 W2 W2 W2 W1 W3 W2W3 W3 W2 W1 W1 W4 W1 W2 W2 W2 W2W2W2 10 0 Stair SA6 Elev EA11 Stair SA6 Elev EA11 F 12'-0" 5' - 0 " 5 A4.1 FN4 FN4 FN4 FN3 FN6 FN2 FN5 FN5 FN4 P1 PL1 PL2 PCT2 P1 REST ROOM 105 CONFERENCE ROOM 106 STORAGE 104 MECH ROOM 110 OFFICE 113 OFFICE 112 OFFICE 111 RECEPTION AREA 101 COPY/FILE ROOM 107 COFFEE BAR AREA 109 OPEN OFFICE 108 OFFICE 103 CONFERENCE ROOM 102 ENTRY ALCOVE 100 P1 P1 PL1 PL2 P1 P1 P1 P1 P1 P1 P1 P1 Stair SA6 Elev EA11 Stair SA6 Elev EA11 VCT1 B1 C2 B1 C1 B1 C1 B1 VCT2 B1 WM1 PCT1 C3 B1 PCT1 B2 C2 B1 C3 B1 C3 B1 C3 B1 VCT1 B1 B2 ADDENDUM 001: 6.30.2011 N N ALL NEW WORKSURFACES TO RECEIVE 3" DIAMETER GROMMETS. NEW GROMMET LOCATIONS TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT. GROMMET COLOR TO BE: BLACK. RADIUS ALL OUTSIDE CORNERS OF COUNTER TOPS. SIZE OF RADIUS TO BE VERIFIED WITH DESIGNER. 13. APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL, AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. 14. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 15. ALL CORE WALLS AND DEMISING WALLS SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. 17. REMOVE EXISTING STOREFRONT DOOR AND FRAME. SAVE FOR REUSE. INSTALL STOREFRONT AND GLASS TO MATCH EXISTING WINDOW. PROVIDE 3/4"x4'x4' FIRE RETARDANT PLYWOOD PHONE BOARD MOUNTED AT 6'-0" AFF TO THE BOTTOM OF THE BOARD. PHONE BOARD TO BE PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH. NEW SEMI-RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. PAINT TO MATCH ADJACENT WALL SURFACE. CONFIRM QUANTITY OF EXTINGUISHERS WITH FIRE DEPARTMENT. IF EXTINGUISHERS NEED TO BE ADDED VERIFY LOCATIONS WITH THE ARCHITECT. EXTEND WALL TO WINDOW MULLION USING SHEETROCK METAL L-TRIM. REFERENCE DETAIL 13/A4.1. ALIGN FINISHED FACES. CONSTRUCTION PLAN NOTES: FP1 FP2 FP3 FP4 FP6 40 0 NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. DENOTES NEW MILLWORK. DENOTES AREA NOT IN CONTRACT. GENERAL CONSTRUCTION NOTES: DIMENSIONS ARE FROM FACE OF FINISHED SURFACE TO FACE OF FINISHED SURFACE UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER. DO NOT SCALE DRAWINGS. 1. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. ALL WALLS TO BE W2 UNLESS NOTED OTHERWISE. 2. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION.3. 4. 5. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. 6. 7. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). 8. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. 9. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS. 10. ALL NEW FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT WALL FINISH AND INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED, A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. 11. 12. 3-5/8" 20 GAUGE METAL STUDS @16"O.C. 4- 7 / 8 " 4- 7 / 8 " PROVIDE 3-5/8" INSULATION INSIDE WALL WALLS TO EXTEND TO DECK ABOVE. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. W2 WALLS TO EXTEND TO DECK ABOVE. 3-5/8" 20 GAUGE METAL STUDS @16"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. W1 EXISTING PARTITION TO REMAIN NEW INSULATED WALL PARTITION NEW NON-INSULATED WALL PARTITION WALL LEGEND: NOTES: USE MOISTURE-MOLD RESISTANT GYPSUM WALLBOARD MEETING ASTM D3273 ON ALL WALL SURFACES RECIEVING FRP PANELS AND IN RESTROOMS. INSULATION FOR INTERIOR WALL APPLICATION SHALL BE FORMALDEHYDE-FREE, UNFACED, GLASS-FIBER BLANKET INSULATION IN BATT FORM CONFORMING TO ASTM C 655, TYPE I, WITH THICKNESS TO BE EQUAL OR GREATER THAN THE STUD THICKNESS OF THE WALL INTO WHICH IT IS INSTALLED. 16.SEE A4.1 FOR DOOR SCHEDULE. ALL PENETRATIONS IN RATED WALL PARTITIONS AND FLOOR SYSTEMS SHALL BE FIRE RATED ASSEMBLIES. SUBMIT PRODUCT DATA AND ASSEMBLY DRAWINGS WITH TEST FILE NUMBERS FOR REVIEW. PROVIDE A WATER METER TO MONITOR WATER SUPPLY TO THE OFFICE SUITE. EXISTING DOOR AND FRAME. 4- 7 / 8 " DECK ABOVE. PROVIDE 3-5/8" INSULATION INSIDE WALL WALL BOARD EACH SIDE. WALLS TO EXTEND TO WITH 5/8" MOISTURE-MOLD RESISTANT GYPSUM W3 3-5/8" 20 GAUGE METAL STUDS @16"O.C. 18.ALL FURNITURE TO BE PROVIDED BY THE TENANT. CONSTRUCTION MANAGER IS TO COORDINATE THE INSTALLATION OF THESE ITEMS WITH THE TENANT. PROVIDE 1/4" COLD COPPER LINE W/VALVE FOR TENANT SUPPLIED COFFEE MAKER AND ICE MAKER. WALLS TO EXTEND TO STRUCTURAL DECK ABOVE. WITH 5/8" GYPSUM WALL BOARD ONE SIDE. W4 3-5/8" 20 GAUGE METAL STUDS @16" O.C. 4- 1 / 4 " PROVIDE MOP SINK WITH FAUCET. SINK TO BE MUSTEE 63M WITH ZURN Z843MI-RC OR EQUAL. FP5 FP7 PROVIDE & INSTALL FLOOR DRAIN WITH STRAINER. COORDINATE WITH MEP CONSULTANTS. PROVIDE NEW WATER HEATER. SIZE UNIT TO FULLY SUPPLY ONE (1) MOP SINK AND TWO (2) HAND SINKS. FP8 PROVIDE NEW REST ROOM. SEE A4.1 FOR DETAILS.FP9 FP10 FP11 REMOVE EXISTING STOREFRONT WINDOW. SAVE FOR REUSE. INSTALL EXISTING RELOCATED DOOR. FP12 PROVIDE MECHO SHADE, DENSE VERTICAL 1000, BLACK/BROWN 1004, MANUAL OPERATION SHADES OR EQUAL. FP13 PROVIDE PLASTIC LAMINATE CABINETS, COUNTER, AND STAINLESS STEEL SINK. SEE ELEVATION 8/A4.1 FOR DETAILS. FP14 PROVIDE PLASTIC LAMINATE CABINETS AND COUNTER. SEE ELEVATION 7/A4.1 FOR DETAILS.FP15 PROVIDE PAINTED HOLLOW METAL FRAME WITH CLEAR GLASS. SEE ELEVATION 2/A4.1 FOR DETAILS. FP16 R R.1 R.2 R.3 R.5 R.6Q.2 Q.5 R R.1 R.2 R.3 R.5 R.6Q.2 Q.5 18.1 18 17.1 17 16.1 16 16.9 18.1 18 17.1 17 16.1 16 16.9 18.1 18 17.1 17 16.1 16 16.9 18.1 18 17.1 17 16.1 16 16.9 R R.1 R.2 R.3 R.5 R.6Q.2 Q.5 R R.1 R.2 R.3 R.5 R.6Q.2 Q.5 FN1 FN2 FN3 FN5 FN6 FN4 1.ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF DESIGNER. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. CONTRACTOR TO VERIFY LEAD TIME AS SOON AS CONTRACT IS AWARDED AND NOTIFY ARCHITECT IF SPECIFIED FINISHES WILL NOT BE AVAILABLE. DESIGN FEES MAY ACCRUE FOR TIME SPENT TO RESELECT ANY MATERIALS WHICH BECOME UNAVAILABLE DUE TO DELAYS IN ORDERING. BASE IN REST ROOMS MUST BE MINIMUM 5" HEIGHT TO MEET BOARD OF HEALTH CODE. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH. ALL NEW DOORS TO BE STAINED ST1 UNLESS NOTED OTHERWISE. ALL HOLLOW METAL DOOR FRAMES TO BE PAINTED SEMI-GLOSS TO MATCH ADJACENT WALL OR PX. 1. 2. 3. 5. 6. 10. 11. 7. 8. GROUT TO HAVE H.B. FULLER CONSTRUCTION PRODUCTS, GROUT BOOST ADDITIVE STAIN BLOCKER. 9. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK TO DESIGNER FOR REVIEW AND APPROVAL BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. PAINT ALL EXPOSED METAL SURFACES (i.e.. GRILLS, HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH ADJACENT SURFACE. PAINT NEW PLYWOOD PHONE BOARD WITH FIRE RETARDANT PAINT. COLOR TO MATCH ADJACENT WALL FINISH. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. ALTERNATES GENERAL FINISH NOTES NOT USED. FINISH PLAN NOTES VINYL BASE MFG: JOHNSONITE COLOR: TBD SIZE: 4" COVE LOCATION: GENERAL CONTACT: BARB LUSTIG, 317.443.8137 B2 CARPET - DIRECT GLUE MFG: $30 BUDGET INSTALL PATTERN: TBD COLOR: TBD LOCATION: GENERAL CONTACT: BASE C1 FLOORCOVERING VINYL COMPOSITE TILE - 12"x12" MFG: MANNINGTON PATTERN: TOUCHSTONE COLOR: TBD LOCATION: COPY/FILE, MECH. ROOMS CONTACT: STEVE PERKINSON, 317-4391710 VCT1 PAINT MFG: SHERWIN WILLIAMS COLOR: TBD FINISH: EGGSHELL LOCATION: GENERAL P1 PAINT PORCELAIN TILE BASE MFG: TBD PATTERN: TBD COLOR: TBD SIZE: LOCATION: ENTRY, REST ROOM FINISH LEGEND MFG: WILSONARTPL1PLASTIC LAMINATE COLOR: TBD FINISH: LOCATION: COUNTERS CONTACT: MFG: WILSONART PLASTIC LAMINATE COLOR: TBD FINISH: LOCATION: CABINETS PL2 PLASTIC LAMINATES WOOD FINISHES WALK-OFF CARPET TILE - 24"X24" MFG: MOHAWK-LEES PATTERN: FIRST STEP II COLOR: TBD INSTALL: QUARTER TURN LOCATION: ENTRY ALCOVE CONTACT: JENNIFER HODGSON, 317-258-5168 P2 PAINT-DRY FOG MFG: SHERWIN WILLIAMS COLOR: SW6991 BLACK MAGIC FINISH: FLAT LOCATION: OPEN CEILING SPECIES: TBD CUT: TBD MFG: MARSHFIELD LOCATION: DOORS COLOR: TBD WOOD STAINST1 RESTROOM WALL TO BE TILED TO 60" AFF W/ SCHLUTER, SCHIENE TRIM XXX AND WITH PAINTED, SMOOTH FINISH DRYWALL ABOVE. SEE ELEVATION 5/A4.1 FOR TILE PATTERN. VINYL TRANSITION BETWEEN CARPET AND VINYL TO BE JOHNSONITE, CTA-40-C, BLACK. ZINC TRANSITION STRIP BETWEEN CARPET AND TILE TO BE SCHLUTER, SCHIENE, AE SATIN ANODIZED ALUMINUM. PORCELAIN TILE - 12"x12" MFG: AMERICAN OLEAN PATTERN: KENDAL SLATE COLOR: TBD GROUT: TBD LOCATION: ENTRY, RESTROOM CONTACT: TRACEY KESSENS-GRIFFIN, 317-366-2835 ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. PAINT EXISTING DOOR AND FRAME TO MATCH WALL. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPET IN PROJECT SCOPE FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. 4. PROVIDE TRANSITION BETWEEN CONCRETE AND CARPET TO BE JOHNSONITE, SSR-XX-B, COLOR XXX. PCT2 WALLCOVERING CERAMIC TILE MFG: CROSSVILLE PATTERN: COLOR BY NUMBER COLOR: TBD GROUT: TBD LOCATION: REST ROOM WALL CONTACT: TRACEY KESSENS-GRIFFIN, 317-366-2835 CONTACT: CARPET - DIRECT GLUE MFG: $30 BUDGET INSTALL PATTERN: TBD COLOR: TBD LOCATION: CONFERENCE ROOMS CONTACT: C2 CARPET - DIRECT GLUE MFG: $30 BUDGET INSTALL PATTERN: TBD COLOR: TBD LOCATION: OFFICES CONTACT: C3 VINYL COMPOSITE TILE - 12"x12" MFG: MANNINGTON PATTERN: TOUCHSTONE COLOR: TBD LOCATION: COFFEE BAR CONTACT: STEVE PERKINSON, 317-4391710 VCT2 B1WM1 PCT1 SCALE: 3/16" = 1'-0" 1 CONSTRUCTION PLAN A1.1 SCALE: 3/16" = 1'-0" 2 FINISH PLAN A1.1