Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.2 - REFLECTED CEILING _ ELECTRICAL DATA PLANS.pdf
Project Number: Revisions: Drawn By Checked ByIssue Date Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: HA R R I S O N & M O B E R L Y , L L P Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - B l d g A 76 0 R a n g e l i n e R o a d , S u i t e 1 6 4 COPYRIGHT & OWNERSHIP OF DOCUMENTS State Release Set: 8/5/16 N PEDCOR DESIGN GROUP A1.2 REFLECTED CEILING / ELECTRICAL DATA PLANS CONSTRUCTION DOCUMENTS MC BR8/5/16 PLAZA LEVEL KEY PLAN N.T.S. THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2016 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 760 Rangeline Road D D D 7' - 3 " 4' - 3 " 7' - 6 1 / 8 " 2' - 4 1 / 4 " 3'-0"6'-1 5/8"8'-0"8'-0"8'-0"4'-0" 6'-1 5/8" 8' - 0 " 8' - 0 " 3' - 9 5 / 8 " 3' - 1 3 / 4 " 8' - 0 " 4'-1/2"4'-1/2" 4'-1/2"4'-1/2" OPEN OPEN 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" OPEN 12'-0"12'-0"12'-0" CP2 CP2 CP2 CP2 CP5 CP5 CP5 CP5 CP1 CP4 CP1 CP4 CP7 CP1 CP4 CP6CP2CP5CP2CP5 CP2 CP5 CP2 CP5 CP6 CP5CP2 CP3 AA AA AA A A A A A A A B B E E A B B B B B B B B C F F D C L C NL NL NL C C C C C C C C C C C C C C C C C C C C C C C C Stair SA6 Elev EA11 Stair SA6 Elev EA11 J F J EP5 EP1 EP3 EP4 EP2 WP +102" REST ROOM 105 CONFERENCE ROOM 106 STORAGE 104 MECH ROOM 110 OFFICE 113 OFFICE 112 OFFICE 111 RECEPTION AREA 101 COPY/FILE ROOM 107 COFFEE BAR AREA 109 GFI GFI GFI D E E E E E OPEN OFFICE 108 +60" +44" +72" +44" +44" E OFFICE 103 CONFERENCE ROOM 102 ENTRY ALCOVE 100 Stair SA6 Elev EA11 Stair SA6 Elev EA11 F PARA LEGAL 5'-6"X8' PARA LEGAL 5'-6"X8' FOUNTAIN N N CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE. ELECTRICAL CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. ALL WALLS GO TO THE DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. GENERAL CEILING NOTES:CEILING PLAN NOTES: PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. COORDINATE ALL SWITCHING AND LOCATIONS WITH THE TENANT AND ARCHITECT. PROVIDE LIGHTING TIMER CONTROL SYSTEM IS TO BE PROVIDED TO MEETING ENERGY CODE. CP1 CP2 12. 14. 5. 6. 4. 1. 2. 3. NL D NIGHTLIGHT LOCATION. LIGHTING CONTROLER W/DIMMER. LIGHTING CONTROLER MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. EMERGENCY LIGHTING SHALL BE CONNECTED TO THE EMERGENCY GENERATOR. PROVIDE OPEN CEILING WITH ALL EXPOSED SURFACES TO BE PAINTED P2. PROVIDE SPIRAL DUCT, HARD PIPE CONDUIT FOR ALL WIRING, AND ALIGNMENT OF ALL VISIBLE ITEMS. CP3 CP4 CP5 CP7 PROVIDE ACOUSTICAL SUSPENSION CEILING SYSTEM TO BE: ARMSTRONG, DUNE TEGULAR 2 X 2 LAY-IN TILE WITH 15/16" PRELUDE XL GRID. 2 X 2 ACOUSTICAL SUSPENSION LAY-IN CEILING SYSTEM. RESTROOM EXHAUST CONNECTION. PROVIDE GRILL IN CEILING FOR CONNECTION TO BUILDING EXHAUST SYSTEM. CP6 PROVIDE LIGHTS ON OCCUPANCY SENSORS. INSTALL ACOUSTICAL CEILING PANELS WITH GRAIN/TEXTURE RUNNING IN THE SAME DIRECTION UNLESS NOTED OTHERWISE. 17. 15. 16.HVAC DIFFUSERS AND GRILLES, FIRE SPRINKLERS ARE TO BE CENTERED WITHIN CEILING TILES. REFLECTED CEILING LEGEND: TIMER CONTROL SYSTEM TO HAVE FOUR (4) CIRCUITS. ALL LIGHTS NOT CONTROLLED WITH OCCUPANCY SENSORS ARE TO BE CONTROLLED ON THE TIMER. COORDINATE CIRCUITS AND SWITCHING WITH THE ARCHITECT. BLOCKING AND SUPPORTS ARE TO BE PROVIDED FOR ALL CEILING MOUNTED FIXTURES AS NEEDED. 10. 11. 9. MEP CONSULTANT TO RUN THE NECESSARY CALCULATIONS TO DETERMINE THAT THE LIGHTING LAYOUT MEETS THE ENERGY CODE. IF IT DOES NOT PLEASE ADDRESS THIS WITH THE ARCHITECT AND THE TENANT TO REVISE LIGHT SELECTIONS AS NEEDED. MEP CONSULTANT IS TO SUBMIT DRAWINGS SHOWING LOCATIONS OF ALL NECESSARY OCCUPANCY SENSORS, HORN STROBES, FIRE PULLS AND EMERGENCY LIGHTS. ALL LIGHT FIXTURES TO BE 3500K COLOR TEMPERATURE. LIGHTING TO BE ON A TIMER. COORDINATE CIRCUITS WITH ARCHITECT AND TENANT. SYMBOL TYPE LIGHT FIXTURE SCHEDULE RECESSED DOWNLIGHT MODEL CREE, 6" LED RECESSED DOWNLIGHT, LR6-10L-35K-120V-A-DR, 3500K W/RC6 HOUSING. WATTAGEDESCRIPTION MOUNTING HEIGHT NOTES D E METALUMEN, HORIZON II 05K, 05K-2L35K-4-CPBO- W-L11PA-1-0. CEILING 96WLINEAR PENDANT FIXTURE 11W 8'-0" AFF TO BOTTOM OF FIXTURE. MERCURY LIGHTING, EDGE LIT LED EXIT SIGNS, MER-ELXTE - RED LETTERS, CLEAR FACE, WHITE HOUSING. EMERGENCY EXIT SIGNS -- MERCURY LIGHTING, LED LOW PROFILE EMERGENCY LIGHT, MER-LEDR1 - WHITE.EMERGENCY LIGHTS -WALL 7. PROVIDE DIMMERS IN THE CONFERENCE ROOM AND OFFICE 113 FOR LIGHTS AS SHOWN. PROVIDE EXHAUST VENT TIED INTO THE BUILDINGS EXHAUST SYSTEM IN THE RESTROOMS. PROVIDE LIGHTING CONTROL TIMER AT THIS LOCATION. OCCUPANCY SENSORS TO BE MOUNTED IN THE CEILING OR ON THE WALL AT A LOCATION THAT SENSES ONLY MOVEMENT FROM INSIDE OF THE ROOM. REVIEW LOCATIONS WITH ARCHITECT. 8. B 35W CEILING WALL SCONCE LAMPS PLUS, PIRELLI LED 10" HIGH SATIN NICKEL WALL SCONCE, 6F692.7.5W 5'-6" TO CENTER OF FIXTURE. LAY-IN TROFFER CREE 2’X2’ LED TROFFER ZR22-32L-35K-10V. F A PENDANT LIGHT FIXTURE 40W C PENDANT LIGHT FIXTURE LAMPS PLUSS, BRUSHED NICKEL SPHERICAL 24" WIDE 6-LIGHT PENDANT LIGHT, T6704. 10'-0" TO BOTTOM OF FIXTURE. W/ DIMMER. 13.COORDINATE HVAC DESIGN WITH STEVE STURTZ AND EXCEL MECHANICAL. IMPACT ARCHITECTURAL LIGHTING, top.ls.tiki LED PENDANT FIXTURE, P4917.LED, MATTE ANODIZED, BLACK POWER CORD AND CANOPY, 3500K LED. 12'-0" TO BOTTOM OF FIXTURE. 60W SOME W/ DIMMER. SOME W/ DIMMER. R R.1 R.2 R.3 R.5 R.6Q.2 Q.5 R R.1 R.2 R.3 R.5 R.6Q.2 Q.5 18.1 18 17.1 17 16.1 16 16.9 18.1 18 17.1 17 16.1 16 16.9 18.1 18 17.1 17 16.1 16 16.9 18.1 18 17.1 17 16.1 16 16.9 R R.1 R.2 R.3 R.5 R.6Q.2 Q.5 R R.1 R.2 R.3 R.5 R.6Q.2 Q.5 GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX, CONDUIT, AND PULL STRING AT PHONE/DATA LOCATIONS AS INDICATED ON PLANS. EXTEND CONDUIT TO ABOVE ACCESSIBLE CEILING OR TO THE DECK ABOVE. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER,CONSTRUCTION MANAGER, AND/OR DESIGN- BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE UNLESS NOTED OTHERWISE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF TO THE CENTER UNLESS NOTED OTHERWISE. ALL OUTLETS ARE TO BE WHITE UNLESS NOTED OTHERWISE. 7. 9. 6. 5. 4. 3. NEW DUPLEX WALL OUTLET. ELECTRICAL/DATA LEGEND: GFI NEW GROUND FAULT INTERRUPT CIRCUIT OUTLET. NEW PHONE/DATA WALL OUTLET (BOX, CONDUIT AND PULL STRING). +44"HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. EP1 EP2 LOCATION OF EXISTING ELECTRICAL PANEL IN THE SERVICE CORRIDOR. PROVIDE ELECTRICAL FOR TENANT PROVIDED AND INSTALLED REFRIGERATOR. EP3 10.ALL PENETRATIONS THROUGH THE DEMISING WALLS BETWEEN TENANTS AND BETWEEN THE TENANT AND THE SERVICE CORRIDOR NEED TO BE FIRE RATED. 11.FIRE ALARM SYSTEM SHALL BE COMPATIBLE AND TIED TO THE EXISTING BUILDING FIRE ALARM SYSTEM. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. 1. 2.ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. NEW ELECTRICAL JUNCTION BOX PROVIDE ELECTRICAL FOR TENANT PROVIDED AND INSTALLED MICROWAVE. PEDCOR IT TO PROVIDE WIRING FROM THE TENANT'S PHONE BOARD TO EACH VOICE/DATA DROP. CONNECTIONS ARE TO BE INCLUDED AT EACH DROP. 8. E DENOTES EXISTING OUTLETS TO REMAIN. EP4 PROVIDE ELECTRICAL FOR NEW WATER HEATER. EP5 PROVIDE ELECTRICAL FOR TENANT PROVIDED AND INSTALLED COPY/PRINTER. NEW QUAD WALL OUTLET. NEW RECESSED IN-FLOOR ELECTRICAL BOX TO BE WIREMOLD/LEGRAND, RFB4 OR EQUAL W/ FOUR (4) ELECTRICAL OUTLETS AND FOUR (4) DATA OUTLES. SCALE: 3/16" = 1'-0" 1 REFLECTED CEILING PLAN A1.2 SCALE: 3/16" = 1'-0" 2 ELECTRICAL/DATA PLAN A1.2