Loading...
HomeMy WebLinkAboutC600 Storm Plan & Profile-C60230' B.L. 15' R.D.E. T/BANK ELEV. = 916.73 50' R/W 50' R/W 50' R/W 50' R/W 50' R/W 50' R/W 30' B-B 30' B-B 30' B-B 30' B-B 40' PVMT. 30' B-B 30' B-B 20' D.&U.E. 20' D.U.&S.S.E. 30' B.L. 30' B.L. 35' B.L. 30' B.L. 30' B.L. 30' B.L. 30' B.L. 30' B.L. 30' B.L. 30' B.L. 30' B.L. 30' B.L. 30' B.L. 30' B.L. 30' B.L. 30'B.L. 15' R.D.E. 15' R.D.E. 15' R.D.E. 15' R.D.E. 15' R.D.E. 10' D.E. 15' R.D.E. 15' R.D.E. VAR. R.D.E. 15' R.D.E. 15' R.D.E. 15' R.D.E. 20' D.U.&S.S.E. 20' D.U.&S.S.E. 20' D.U.&S.S.E. 20' D.U.&S.S.E. 20' D.U.&S.S.E. 20' D.&U.E. 20' D.&U.E. 20' D.&U.E. 20' D.&U.E. 30' D.U.&S.S.E 20' D.&U.E. 20' D.&U.E. 20' D.&U.E. 20' D.U.&S.S.E. 20' D.&U.E. 10' BUFFER EASEMENT 10' BUFFER EASEMENT 10' BUFFER EASEMENT TALLYN WAY TALLYN WAY TAMERLANE PLACE TAMSYN CIRCLE 50' R/W 30' B-B 50' R/W 30' B-B TRAHAN DRIVE TRAHAN DRIVE 1 2 3 4 5 6 7 10 9 11 12 13 15 16 17 18 20 21 22 23 24 25 26 27 8 19 20' R.D.E.& B.M.P.E. 20' R.D.E.& B.M.P.E. 20' R.D.E.& B.M.P.E. 15' R.D.E. 15' R.D.E. 15' R.D.E. T.O.B. T.O.B. T.O.B. T.O.B. T.O.B. N.P.= 10 YEAR ELEV.= 2 YEAR ELEV.= 100 YEAR ELEV.= BOTTOM ELEV.= LAKE #1 914.03 914.34 914.60 915.54 906.03 N.P.= 10 YEAR ELEV.= 2 YEAR ELEV.= 100 YEAR ELEV.= BOTTOM ELEV.= LAKE #2 (BMP) 911.53 912.53 913.45 914.99 903.53 T/BANK ELEV. = 916.23 20' D.U.&S.S.E. 20' D.U.&S.S.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E. 15' U.E. VAR. R.D.E. 15' 10' BUFFER EASEMENT 10' BUFFER EASEMENT VAR. L.M.A.E. 15' R.D.E. 15' R.D.E. 5' R.D.E. VAR. R.D.E. 30' R.D.E.&U.E. 30' R.D.E.&U.E. 30' R.D.E.&U.E. 20' R.D.E.& B.M.P.E. VAR. R.D.E. 10' D.E. 10' D.E. 15' R.D.E. 10' D.E. 10' D.E. VAR. R.D.E. VAR. R.D.E.&B.M.P.E. 50' R/W 17.8' 18.2' 29.2' 110.7' (NO EVIDENCE) YARD INLET #120 EJ-6489-N [STD MH] STA. 3+72 TC=916.24 129 L.F. 0.16% 21" R.C.P. CLASS III 912.13 911.93 DBL CURB INLET #119 EJ-7495-M1/M2 [SPEC. STR.] STA. 2+43 TC=916.58 30 L.F. 0.23% 21" R.C.P. CLASS III UP INV.=911.93 DOWN INV.=911.86 57 L.F. 0.20% 24" R.C.P. CLASS III 911.75 911.86 123 L.F. 0.16% 24" R.C.P. CLASS III 911.55 911.75 MANHOLE #116 EJ-1045 [STD MH] STA. 0+00 TC=916.70 EXISTING GRADE PROPOSED GRADE TRAHAN DRIVE 8" S.D.R. 35 P.V.C INV.=907.41 YARD INLET #121 EJ-6489-N [STD MH] STA. 8+70 TC=917.04 498 L.F. 0.25% 18" R.C.P. CLASS III 913.35 912.13 TC=917.49 40 L.F. 0.25% 15" R.C.P. CLASS III UP INV.=913.45 DOWN INV.=913.35 36 L.F. 0.61% 24" R.C.P. CLASS III UP INV.=911.55 DOWN INV.=911.33 N.P.=911.53 END SECTION #115 STA. 0+01 EXISTING GRADE PROPOSED GRADE DBL CURB INLET #118 EJ-7495-M1/M2 [SPEC. STR.] W/ 2' SUMP STA. 2+13 TC=916.71 MANHOLE #117 EJ-1045 [STD MH] STA. 1+57 TC=917.15 24" R.C.P. W INV.=911.55 24" R.C.P. E INV.=911.55 12" R.C.P. N INV.=911.65 6"S.S.D. 6"S.S.D. 6"S.S.D. 6"S.S.D. 6"S.S.D. HYDRAULIC GRADE LINE 3 3 % 0.15 0.15 % 0.15 % 0.15 % 0.15 % 3 500 130 3 56 120 38 3 3 3 912.10 912.10 911.90 911.90 911.85 911.85 911.77 911.77 911.59 911.59 911.59 911.69 911.59 911.53 917.64 917.10 916.00 916.68 916.68 917.24 916.60 SCALE: 1"=50' HOR. 1"=5' VERT. YARD INLET #121 EJ-6489-N [STD MH] STA. 8+70 TC=917.04 913.35 CURB INLET #94 EJ-7495-M4 [2' x 2' BOX] STA. 9+10 TC=917.49 40 L.F. 0.25% 15" R.C.P. CLASS III UP INV.=913.45 DOWN INV.=913.35 30 L.F. 0.23% 15" R.C.P. CLASS III UP INV.=913.52 DOWN INV.=913.45 CURB INLET #95 EJ-7495-M4 [STD MH] STA. 9+40 TC=917.50 167 L.F. 0.23% 15" R.C.P. CLASS III 913.52 913.90 YARD INLET #96 EJ-6489-N [2' x 2' BOX] STA. 11+08 TC=917.80 30 L.F. 0.43% 12" R.C.P. CLASS III 913.90 914.03 END SECTION #97 STA. 11+38 TRAHAN DRIVE 6"S.S.D. 6"S.S.D. 6"S.S.D. 6"S.S.D. 0.30 % 0.24 % 0.25 % 3 33 3 3 3 3 913.93 913.93 913.53 913.53 3 3 3 3 917.70 917.64 917.64 917.10 DATE MARK REVISIONS BY CERTIFIED: S & A JOB NO. SHEET NO. DRAWN BY: CHECKED BY: 672(33(/:(57+ $/:$<621 (DVWWK6WUHHW)LVKHUV,1 SKRQHID[ STORM PLAN & PROFILE C602 REVISED PER CLIENT COMMENTS ADG ASBUILTS ADG CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OR CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS AND 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. STORM SEWER NOTE 67302PLA TALLYN'S RIDGE JSM/ADG BAH CLAY TOWNSHIP HAMILTON COUNTY, INDIANA 11/25/2015 APPROVAL PENDING NOT FOR CONSTRUCTION 08/21/15 11/25/15 REVISED PLANS PER NEW DEVELOPER 01/18/16 REVISED PER CROSSROADS COMMENTS ADG MATCH LINE "A" Know what's R CONSTRUCTION LIMITS MATCH LINE "A" 1" = 50 FT NOTES: ALL STORM STRUCTURES TO RECEIVE SOLID LID CASTINGS ARE TO BE CONSTRUCTED TO PROVIDE ONE 4" RISER RING NO MORE, NO LESS TO ACHIEVE PLAN RIM GRADE. ALL YARD INLETS ARE TO BE CONSTRUCTED AT A TOLERANCE OF +0.00' TO -0.20' OF PLAN GRADE. ALL STORM SEWER CASTINGS SHALL BE LABELED "DUMP NO WASTE-DRAINS TO WATERWAY" ALL SSD'S (SUBSURFACE DRAINS) WILL NEED TO BE DOUBLE WALL SMOOTH BORE PERFORATED (HDPE) PIPE. DEBRIS GUARDS ARE TO BE INSTALLED ON ALL OPEN ENDED INLETS. FOR STORM STRUCTURE SIZING AND CASTING TABLE SEE SHT. C203. ALL STORM SEWERS WITHIN PUBLIC RIGHT-OF-WAY SHALL BE RCP CLASS III. FOR INSTALLATION OF STORM UNDER CITY STREETS AND COVER REQUIREMENTS, SEE SHEETS No. C802 ON THE TRENCH DETAIL. THERE SHOULD BE NO LESS THAN 2.5 FEET OF COVER ALONG ANY PART OF THE PIPE FROM FINAL PAVEMENT OR FINAL GROUND SURFACE ELEVATION TO THE TOP OF THE PIPE. DENOTES FULL DEPTH GRANULAR BACKFILL (SEE RCP TRENCH DETAIL 10-28 ON SHEET C802 FOR MATERIAL AND SPECIFICATIONS.)