HomeMy WebLinkAboutC600 Storm Plan & Profile-C60330' B.L.
30' B.L.
15' R.D.E.
15' R.D.E.
15' R.D.E.
15' R.D.E.
20' D.U.&S.S.E. 20' D.U.&S.S.E.
20' D.&U.E. 20' D.&U.E.
20' D.&U.E.
30' R.D.E.
10' BUFFER EASEMENT
5' BUFFER YARD
30' B-B
50' R/W
30' B-B
TRAHAN DRIVE
12
13
14
15
20' R.D.E.& B.M.P.E.
20' R.D.E.& B.M.P.E.
T.O.B.
EXISTING R.D.E.
INSTR. No. 2014015099
EXISTING R.D.E.
INSTR. No. 2014015099
15' U.E.
15'
20' A.E.
VAR. L.M.A.E.
VAR. L.M.A.E.
N.P.=
10 YEAR ELEV.=
2 YEAR ELEV.=
100 YEAR ELEV.=
BOTTOM ELEV.=
BIO-SWALE (BMP)
909.60
911.19
911.63
912.61
901.60
(LAKE - BY OTHERS)
STOCKPILE
30' R.D.E.&U.E.
25'
20' R.D.E.& B.M.P.E.
15' U.E.
15'
30' R.D.E.
30'
30' R.D.E.
30'
SCALE: 1"=50' HOR.
1"=5' VERT.
112 L.F. 0.18% 18" R.C.P. CLASS III
911.24
911.44
MANHOLE #106
EJ-1045 [STD MH]
STA. 7+93
TC=918.62
491 L.F. 0.18% 18" R.C.P. CLASS III
910.25
911.14
MANHOLE #115A
EJ-1045 [STD MH]
STA. 3+01
TC=918.42
MANHOLE #813
EJ-1045 [STD MH]
STA. 0+91
TC=917.35
211 L.F. 0.18% 18" R.C.P. CLASS III
909.77 910.15
8" S.D.R. 35 P.V.C
EXISTING GRADE
EXISTING GRADE
91 L.F. 0.18% 18" R.C.P. CLASS III
909.51 909.67
END SECTION #814
STA. 0+00
N.P.=911.53
PROPOSED GRADE
TRAHAN DRIVE
OUTLET CONTROL #107
SEE DETAIL C603
STA. 9+05
TC=914.62
PROPOSED GRADE
N.P.=909.60
HYDRAULIC GRADE LINE
93 3
3 493
909.60 110
909.77 909.87
910.25 910.35
911.24
911.34
911.53
917.15
918.23
918.50
914.54
3
3 3
SCALE: 1"=50' HOR.
1"=5' VERT.
OUTLET CONTROL #809
SEE DETAIL C603
STA. 4+00
TC=911.86
81 L.F. 0.18% 18" R.C.P.
CLASS III
909.40
909.54
319 L.F. 0.18% 18" R.C.P. CLASS III
908.74
909.30
MANHOLE #810
EJ-1045 [STD MH]
STA. 3+19
TC=916.96
END SECTION #811
STA. 0+00
PROPOSED GRADE
EXISTING GRADE
EX. SWALE=908.4
HYDRAULIC GRADE LINE
0.20 %
%
0.20
320
85
908.69
909.33
909.43 909.60
916.66
912.00
PRIOR TO FABRICATION & INSTALLATION
OUTLET CONTROL STRUCTURE #107 DETAIL
NOT TO SCALE
18" R.C.P.
30"
NOTE:
LAKE
18" R.C.P.
INV.= 911.53
30"
42" NTS
30"
METHOD OF ATTACHING TO OUTLET STRUCTURE
CONTRACTOR SHALL VERIFY PROPER
6" 6" 6" 6"
LAKE
PROPOSED GRADE
NORMAL POOL=911.53
CAST IRON
TRASH GUARD
GALVANIZED OR
CAST IRON
GALVENIZED OR
TRASH GUARD
6" ORFICE
INV.=911.53
6" ORFICE
INV.=913.0
TOP
ELEV.=914.85
PRIOR TO FABRICATION & INSTALLATION
OUTLET CONTROL STRUCTURE #809 DETAIL
NOT TO SCALE
18" R.C.P.
30"
30"
CAST IRON
6" ORFICE
INV.=909.60
NOTE:
LAKE
18" R.C.P.
INV.= 909.60
42" NTS
30"
METHOD OF ATTACHING TO OUTLET STRUCTURE
CONTRACTOR SHALL VERIFY PROPER
6" 6" 6" 6"
LAKE
PROPOSED GRADE
NORMAL POOL=909.60
CAST IRON
TRASH GUARD
GALVANIZED OR
GALVENIZED OR
TRASH GUARD
6"x18" ORFICE
INV.=911.0
TOP
ELEV.=912.0
DATE MARK REVISIONS BY
CERTIFIED:
S & A JOB NO.
SHEET NO.
DRAWN BY: CHECKED BY:
672(33(/:(57+
$/:$<621
(DVWWK6WUHHW)LVKHUV,1
SKRQHID[
STORM PLAN & PROFILE
C603
REVISED PER CLIENT COMMENTS ADG
ASBUILTS ADG
CONTRACTOR SHALL VERIFY DEPTHS OF ALL
EXISTING ONSITE UTILITIES PRIOR TO
CONSTRUCTION TO CONFIRM THERE IS NOT
ANY CONFLICTS WITH OTHER UTILITIES, STORM
SEWERS OR STREETS. CONFLICTS AFTER
CONSTRUCTION BEGINS ARE SOLELY THE
CONTRACTOR'S RESPONSIBILITY.
THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED
PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY
OF CARMEL ON THE FINAL APPROVED CONSTRUCTION
PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL
ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES
OR DIFFICULTY DURING CONSTRUCTION AND WILL
REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED
REPRESENTATIVE OF THE CITY OR CARMEL IN ADDITION
TO SUPPLEMENTAL APPROVAL BY THE DESIGN
ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION
SHALL BE INCLUDED AS A REQUIREMENT ON
AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE
OF PERFORMANCE GUARANTEES. APPROVED DESIGN
SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5
FPS OR LESS AND 10 FPS OR GREATER (AT FULL FLOW
CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT
THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING
THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT
EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED
TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND
AS APPROVED BY THE CITY OF CARMEL.
STORM SEWER NOTE
67302PLA
TALLYN'S RIDGE
JSM/ADG BAH
CLAY TOWNSHIP HAMILTON COUNTY, INDIANA
11/25/2015
APPROVAL PENDING
NOT FOR CONSTRUCTION
08/21/15
11/25/15 REVISED PLANS PER NEW DEVELOPER
01/18/16 REVISED PER CROSSROADS COMMENTS ADG
Know what's
R
CONSTRUCTION LIMITS
1" = 50 FT
NOTES:
ALL STORM STRUCTURES TO RECEIVE SOLID LID
CASTINGS ARE TO BE CONSTRUCTED TO
PROVIDE ONE 4" RISER RING NO MORE, NO LESS
TO ACHIEVE PLAN RIM GRADE.
ALL YARD INLETS ARE TO BE CONSTRUCTED AT
A TOLERANCE OF +0.00' TO -0.20' OF PLAN GRADE.
ALL STORM SEWER CASTINGS SHALL BE
LABELED
"DUMP NO WASTE-DRAINS TO WATERWAY"
ALL SSD'S (SUBSURFACE DRAINS) WILL NEED TO
BE DOUBLE WALL SMOOTH BORE PERFORATED
(HDPE) PIPE.
DEBRIS GUARDS ARE TO BE INSTALLED ON ALL
OPEN ENDED INLETS.
FOR STORM STRUCTURE SIZING AND CASTING
TABLE SEE SHT. C203.
ALL STORM SEWERS WITHIN PUBLIC
RIGHT-OF-WAY SHALL BE RCP CLASS III.
FOR INSTALLATION OF STORM UNDER CITY
STREETS AND COVER REQUIREMENTS, SEE
SHEETS No. C802 ON THE TRENCH DETAIL.
THERE SHOULD BE NO LESS THAN 2.5 FEET OF
COVER ALONG ANY PART OF THE PIPE FROM
FINAL PAVEMENT OR FINAL GROUND SURFACE
ELEVATION TO THE TOP OF THE PIPE.
DENOTES FULL DEPTH GRANULAR
BACKFILL
(SEE RCP TRENCH DETAIL 10-28 ON SHEET C802
FOR MATERIAL AND SPECIFICATIONS.)