Loading...
HomeMy WebLinkAboutC201 Emergency Flood Plan-C201Know what's R 50'25'50'0 GRAPHIC SCALE ( IN FEET ) 1" = 50 FT 55115PYT-S1 TH E G R O V E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 07 2 2 / 2 0 1 6 Fi l e N a m e : S: \ 5 5 1 1 5 - P Y T - S 1 \ D W G \ C 2 0 1 E m e r g e n c y F l o o d P l a n . d w g - C2 0 1 Mo d i f i e d / B y : Se p t e m b e r 2 8 , 2 0 1 6 1 0 : 4 0 : 2 9 A M / jm c w h o r t e r Pl o t t e d / B y : Se p t e m b e r 2 8 , 2 0 1 6 1 0 : 4 1 : 3 8 A M / Pa u l R i c h a r d s at T H E L E G A C Y AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N 08 / 2 3 / 1 6 PD R RE V I S I O N S P E R T A C C O M M E N T S EXISTING CONTOUR EXISTING SANITARY SEWER EXISTING STORM SEWER PROPOSED GRADE PROPOSED CONTOUR PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED WATER LINE PROPOSED SWALE PROPOSED 5' SIDEWALK (BY HOME BUILDER) (DEVELOPER SHALL INSTALL SIDEWALKS ALONG ALL COMMON AREAS) »ADA RAMP TO BE INSTALLED DENOTES REAR FLOOD PROTECTION GRADE (SEE SHEET C201 FOR FLOOD PROTECTION NOTES) LOT NUMBER PAD ELEVATION DENOTES FRONT FLOOD PROTECTION GRADE (SEE SHEET C201 FOR FLOOD PROTECTION NOTES) PROPOSDED 6" UNDERDRAINS MINIMUM FINISH FLOOR ELEVATION IS BASED OFF OF THE BELOW 1. (1') ABOVE THE NEAREST UPSTREAM OR DOWNSTREAM SANITARY MANHOLE, WHICHEVER IS LOWEST. 2. 6" (0.5') ABOVE THE MLAG MINIMUM LOWEST ADJACENT GRADE (FLOOD PROTECTION) 870 848.0 870 W > o o o 757.5 25 XXX.X XXX.X VEGETATIVE COVER EXISTING SITE CONSIST MOSTLY OF GRASS AND WEEDS WITH WOODS ON THE SITE. ADJACENT PROPERTIES NORTH: GRASS & WEEDS EAST: RESIDENTIAL SOUTH: RESIDENTIAL WEST: RESIDENTIAL FLOOD STATEMENT A PORTION OF THIS SITE LIES WITHIN A ZONE "X" (500 YEAR FLOODPLAIN) PER FIRM 18057C0235F DATED FEB. 19, 2003. HOWEVER, NO PORTION OF THIS SITE LIES WITHIN A ZONE A. BASED ON THE FEMA BASE FLOOD ELEVATION FOR THIS AREA, THERE WILL BE NO POTENTIAL FLOODING OF THIS PROPERTY VIA OUTFALL OR STORM PIPING SYSTEMS. EMERGENCY FLOOD ROUTING EMERGENCY OVERFLOW PONDING (FOR 100 YEAR STORM ASSUMING ALL INLETS ARE COMPLETELY CLOGGED.) Minimum Flood Protection Grades From Sections 104.02, 302.06 and 303.07 of the City of Carmel Storm Water Technical Standards Manual 1. Definitions a.Minimum Flood Protection Grade of all structures fronting a pond or open ditch shall be no less than 2 feet above any adjacent 100-year local or regional flood elevations, whichever is greater, for all windows, doors, pipe entrances, window wells, and any other structure member where floodwaters can enter a building. b.Lowest Adjacent Grade is the elevation of the lowest grade adjacent to a structure, where the soil meets the foundation around the outside of the structure (including structural members such as basement walkout, patios, decks, porches, support posts or piers, and rim of the window well. 2. Standard: Lowest Adjacent Grade a.General i.The Lowest Adjacent Grade for residential, commercial, or industrial buildings shall have two feet of freeboard above the flooding source's 100-year flood elevation under proposed conditions. b.For areas outside a Special Flood Hazards Area (SFHA) or FEMA or IDNR designated floodplain i.The Lowest Adjacent Grade for all residential, commercial, or industrial buildings adjacent to ponds shall be set a minimum of 2 feet above the 100-year pond elevation or 2 feet above the emergency overflow weir elevation, whichever is higher. ii.The Lowest Adjacent Grade for all residential, commercial, or industrial buildings shall be set a minimum of 2 feet above the highest noted overflow path/ponding elevation across the property frontage. iii.In addition to the Lowest Adjacent Grade requirements, any basement floor must be at least a foot above the normal water level of any wet-bottom pond. 3. Design Notes: a. Each lot that is adjacent to a pond, open ditch or flooding source has a flood protection grade. There are instances where there are multiple different flooding sources for 1 structure. In this case, there should be a flood protection grade listed for each side of the structure in the event that piping from the structure discharge to either flood source. b. Finished floor elevation or the lowest building entry elevation shall be no less than 6 inches above finished grade around the building. Also, the building's lowest entry elevation that is adjacent to and facing a road shall be a minimum of 15 inches above the road elevation. DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               EM E R G E N C Y F L O O D R O U T I N G C201