Loading...
HomeMy WebLinkAboutC700 Water Plan-C700Know what's R 50'25'50'0 GRAPHIC SCALE ( IN FEET ) 1" = 50 FT 55115PYT-S1 TH E G R O V E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 07 2 2 / 2 0 1 6 Fi l e N a m e : S: \ 5 5 1 1 5 - P Y T - S 1 \ D W G \ C 7 0 0 W a t e r P l a n . d w g - C7 0 0 Mo d i f i e d / B y : Au g u s t 3 1 , 2 0 1 6 2 : 4 5 : 0 1 P M / pr i c h a r d s Pl o t t e d / B y : Se p t e m b e r 2 8 , 2 0 1 6 1 1 : 0 6 : 3 5 A M / Pa u l R i c h a r d s at T H E L E G A C Y AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N 08 / 2 3 / 1 6 PD R RE V I S I O N S P E R T A C C O M M E N T S M PROPOSED HYDRANT W/6" VALVE VALVE BLOW OFF ASSEMBLY REDUCER EX. WATER METER EX. WATER VALVE EX. FIRE HYDRANT LEGEND LENGTH OF IPE TO BE RESTRAINED PRESSURE PIPE JOINT RESTRAINT TABLE IN EACH DIRECTION FROM 1/4 OF BEND BASED ON 150 psi TEST PRESSURE DEGREE OF BEND & PLUGS ƒ7((6 ƒ ƒ ƒ 6"8"10"12"14"16"18"20"24"30" 27'35'42'50'58'65'73'80'95'115' 7'9'11'13'15'17'19'21'24'29' 3'4'5'6'7'8'9'10'12'14' 2'2'3'3'4'4'4'5'6'7' RESTRAINED JOINTS SHALL BE MECHANICAL JOINT WITH RETAINER GLANDS, US PIPE TR FLEX JOINT SYSTEM, US PIPE FIELD LOK GASKET SYSTEM. NOTE: THE ABOVE RESTRAINED JOINT LENGTHS ARE MINIMUM LENGTHS THE DESIGN ENGINEER SHALL DETERMINE IF LONGER LENGTHS ARE REQUIRED. NOTES: NO EARTH DISTURBING ACTIVITIES MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. FOR INSTALLATION OF SANITARY AND WATER UNDER CITY STREETS AND COVER REQUIREMENTS, SEE THE TRENCH DETAIL ON SHEET C700. THERE ARE TO BE NO WATER VALVES OR MANHOLES WITHIN THE PAVEMENT, CURB, OR SIDEWALK WITH THE EXCEPTION OF CURB INLETS. ALL WATERMAIN SERVICE LINES TO TERMINATE 5 FEET BEHIND SIDEWALK AND MARKED WITH A 4" PVC PIPE WITH A PAINTED BLUE TOP. POSI-CAPS OR EQUIVALENT IS REQUIRED ON ALL WATER VALVE INSTALLATION AND MEGA LUGS MUST BE INSTALLED AT ALL MECHANICAL JOINTS. ALL DUCTILE IRON WATERMAINS SHALL BE BEDDED IN SAND, FROM THE BOTTOM OF THE TRENCH TO 12" ABOVE THE PIPE INSTALL WATERMAIN TRACER WIRE WITH ALL WATER MAINS LAID AND BLUE REFLECTOR TAPE MUST BE INSTALLED 12" TO 18" ABOVE ALL WATERMAINS LAID, ALL WATERMAINS SHALL BE DUCTILE IRON AND INSTALLED PER THE CITY OF CARMEL SPECIFICATIONS FULL DEPTH GRANULAR BACKFILL PER CITY STANDARDS SHALL BE PLACED FOR ALL STREET CROSSINGS FIRE HYDRANT MARKERS TO BE INSTALLED IN THE STREET PAVEMENT PERPENDICULAR TO THE FIRE HYDRANT. ONLY MUELLER HYDRANTS AND VALVES MAY BE USED. DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               WA T E R P L A N C700