Loading...
HomeMy WebLinkAboutC800 Construction Details-C801DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: 6 7  2  (  3  3  (  /  :  (  5  7  + $ /  :  $  <  6   2  1     ( D V W     W K  6 W U H H W    ) L V K H U V   , 1             SK R Q H                  I D [               ST O R M S E W E R D E T A I L S C801 LABELED "DUMP NO WASTE". NOTE: ALL CASTINGS SHALL BE*NOTE TO CONTRACTOR: THE CITY OF CARMEL REQUIRES DOUBLE WALL HANCOR HI-Q SSD PIPE OR EQUAL TO BE USED. 1. 2. NOTES: The storm sewer system shall be constructed per design specified and as approved by the City of Carmel on the final approved construction plans. Deviations from the approved design shall only be permitted due to special circumstances or difficulty during construction and will require prior field approval from a designated representative of the City of Carmel in addition to supplemental approval by the design engineer. An explanation of any such deviation shall be included as a requirement on as-built/record drawings submitted for release of performance guarantees. Approved design slopes identified as generating velocities of 2.5 fps or less or 10 fps or greater (at full flow capacity) shall require as-built certification at the time of construction, prior to backfilling the pipe. The contractor is instructed to as-built each section of storm pipe as it is being installed to ensure compliance with the design plans and as approved by the City of Carmel. All storm sewers shall be constructed with reinforced concrete pipe Class III or as noted and conform to A.S.T.M. C-76 or latest revision. All manholes shall be precast concrete construction in accordance with State of Indiana Specifications and shall have Type "A" cast iron ring and cover. A PRECAST CONCRETE END SECTION DETAIL APPLICABLE PORTIONS OF A.S.T.M. SPECIFICATION C76. NOTES: 1. MANUFACTURE OF END SECTION IS IN ACCORDANCE WITH SECTION A-A SECTION B-B VERTICAL FLARE HORIZONTAL FLARE R-2 "A""A" "B" "B" DIA.E WALL D SKIRT (GROOVE-OUTLET END) (TONGUE-INLET END) WA L L DIA. WALL 0.0704' DIA.+1 BC WALL 1/32 TAPER PER INCH PER SIDE. R- 1 DIA . 1 1/2"R DIA . 1 1/2"R R- 1 6 6 1/2 5 5 1/2 4 1/2 3 3/4 3 1/4 3 1/2 SKIRT 3 1/2 3 1/2 4 4 4 1/2 4 1/2 5 5 1/2 5 1/2 5 1/2 5 3/4 6 3/4 7 1/4 7 3/4 8 1/2 9 6 1/4 R-2 9 11 12 13 14 14 1/2 15 17 1/2 20 22 22 24 24 24 24 24 24 R-1 10 1/16 12 1/2 15 1/2 16 1/8 16 11/16 17 3/4 18 5/16 23 3/4 24 1/16 27 1/4 28 1/8 36 3/4 35 11/16 38 5/8 41 15/16 44 13/16 32 7/8 DIA. +1 13 16 19 22 25 28 31 34 37 43 49 61 67 73 79 85 55 E 24 30 36 42 48 54 60 66 72 78 84 96 102 108 114 120 90 D 72 7/8 73 73 73 73 1/2 73 1/2 73 3/4 97 3/4 97 3/4 98 98 99 99 99 99 99 100 C 48 1/8 46 46 38 30 25 1/2 19 3/4 39 1/4 34 3/4 35 26 39 21 21 21 21 35 B 24 27 27 35 43 1/2 48 54 58 1/2 63 63 72 60 78 78 78 78 65 A 4 6 9 9 9 1/2 10 1/2 12 13 1/3 15 21 24 30 24 34 24 24 27 WT. SEC 530 740 990 1280 1520 1930 2190 3150 4100 5380 6550 8750 10630 12520 14430 16350 8040 G or T 1 1/2 2 2 1/2 2 1/4 2 1/2 2 1/2 3 3 3/8 3 1/2 3 3/4 4 1/4 5 5 1/2 6 6 1/2 7 4 3/4 WALL 2 2 1/4 2 1/2 2 3/4 3 4 7 7 1/2 8 DIA. 12 15 18 21 24 27 30 33 36 42 48 54 60 66 72 78 84 2500 psi CONCRETE BOTTOM OF TRENCH PERSPECTIVE VIEW - EARTH CUT AWAY TO BE USED WHEN CLEAR DISTANCE BETWEEN PIPES IS 24" OR LESS, OR WERE NOTED ON THE DRAWINGS. NOT-TO-SCALE CONCRETE CRADLE 5'- 0 " M I N 5'- 0 " M I N 5'-0" MIN 5'-0" M I N 55115PYT-S1 TH E G R O V E JSM BAH CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 07 2 2 / 2 0 1 6 Fi l e N a m e : S: \ 5 5 1 1 5 - P Y T - S 1 \ D W G \ C 8 0 0 C o n s t r u c t i o n D e t a i l s . d w g - C8 0 1 Mo d i f i e d / B y : Se p t e m b e r 1 , 2 0 1 6 1 2 : 1 0 : 0 1 P M / pr i c h a r d s Pl o t t e d / B y : Se p t e m b e r 1 , 2 0 1 6 1 2 : 1 4 : 2 6 P M / Pa u l R i c h a r d s at T H E L E G A C Y AP P R O V A L P E N D I N G / N O T F O R C O N S T R U C T I O N 08 / 2 3 / 1 6 PD R RE V I S I O N S P E R T A C C O M M E N T S NOT-TO-SCALE 24"x64" INLET DOUBLE CURB INLET SIDE VIEW PLAN VIEW 76.0" 24 . 0 " 8. 0 " 76.0" 24 . 0 " 6. 0 " 6. 0 " PLAN VIEW 76.0" 24 . 0 " 6. 0 " 6. 0 " 36 . 0 " 36 . 0 " 6.0"6.0"6.0"6.0"64.0" 8. 0 " SIDE VIEW NOT-TO-SCALE 24"x64" DOUBLE INLET FLAT TOP NOT-TO-SCALE 60" I.D. MONOLITHIC BASE SIDE VIEW PLAN VIEW 72.0" 60 . 0 " - B A S E / 8 " - 6 0 " 8. 0 " PLAN VIEW 14 . 0 " SIDE VIEW NOT-TO-SCALE DOUBLE CURB INLET MANHOLE 60" I.D. FLAT TOP w/ (2) 24" SQUARE HOLE CASTINGS SUPPLIED BY CUSTOMER NOTE: OPENINGS BASE ON PIPE O.D.+4" NOTE: HOLES FOR PIPE UNDERDRAINS SUPPLIED IF REQUIRED. 24 X 24 SQ. OPENING 12-#5 REBAR AROUND OPENINGS #4 BARS @ 6" C.C. EACH WAY (2" CLEAR I.B.) ‘,' M.A. INDUSTRIES PLASTIC STEPS 16" O.C. 24 X 24 SQ. OPENING 8-#5 REBAR AROUND OPENING 7. 0 " 72 . 0 " #4 BARS @ 6" C.C. EACH WAY (2" CLEAR I.B.) 36"x36" 30"x30" 6" CONC. PIPE REINFORCED CONCRETE BASE WEEP HOLES FOR CASTING TYPES SEE STRUCTURE DATA CHART FINISH GRADE 2'-0" 4" VARIES 0'-3" MIN. 2.5' MIN. CURB INLET CATCH BASIN NOT-TO-SCALE YARD INLET CATCH BASIN NOT-TO-SCALE FOR CASTING TYPES SEE STRUCTURE DATA CHART 24"x24" 2.5' MIN. NOTE: MAXIMUM 48 INCHES FROM T/C TO INVERT