Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
15080065 As Built
2009 IECC ANNUAL ENERGY COST COMPLIANCE Date: September 30, 2016 Rating No.: Building Name: Rating Org.: TSI ENERGY SOLUTIONS Owner's Name: JONES BUILDING GROUP Phone No.: 317-846-4655 Property: 10540 HUSSEY LN Rater's Name: MICHAEL HILL Address: CARMEL (AS BUILT), IN 46032 Rater's No.: 9479271 Builder's Name: JONES BUILDING GROUP Weather Site: Indianapolis, IN Rating Type: Confirmed File Name: BAHLER_JONES_10082759.blg Rating Date: 09-30-2016 REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cos t or savings. © 1985-2016 Noresco, Boulder, Colorado. Annual Energy Cost ($) 2009 IECC As Designed Heating:1949 1635 Cooling:438 330 Water Heating: 218 250 SubTotal - Used to Determine Compliance:2604 2215 Lights & Appliances:1644 1665 Photovoltaics:-0 -0 Service Charge: 248 248 Total:4496 4128 * Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 6.0 Wi ndow U-Factor Check (Section 402.5) Wi ndow U-Factor (Design must be equal or lower): 0.480 0.300 Home Infiltration (Section 402.4.2):PASSES Duct Leakage (Section 403.2.2):PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 14.9%. Name:MICHAEL HILL Signature: Organization:TSI ENERGY SOLUTIONS Date:September 30, 2016 2009 IECC ANNUAL ENERGY COST COMPLIANCE BAHLER_JONES_10082759.blg Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cos t or savings. © 1985-2016 Noresco, Boulder, Colorado. * Design energy cost is based on the following systems: Heating: Fuel-fired air distribution, 77.6 kBtuh, 97.0 AFUE. Heating: Fuel-fired air distribution, 59.0 kBtuh, 97.0 AFUE. Cooling: Air conditioner, 41.5 kBtuh, 16.5 SEER. Cooling: Air conditioner, 29.0 kBtuh, 16.5 SEER. Water Heating: Conventional, Gas, 0.58 EF. Wi ndow-to-Floor Area Ratio: 0.09 Blower door test: Htg: 0.30 Clg: 0.30 ACHnat In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. H O M E C E R T I F I E D T O M E E T T H E P R O V I S I O N S O F T H E 20 0 9 I N T E R N A T I O N A L E N E R G Y C O N S E R V A T I O N C O D E Th i s h o m e b u i l t a t 10 5 4 0 H U SS E Y L N , CA R M E L ( A S B U I L T ) , I N by J O N E S B U I L D I N G G R O U P ex c e e d s t h e m i n i m u m r e q u i r e m e n t s f o r t h e 2 0 0 9 I n t e r n a t i o n a l E n e r g y C o n s e r v a t i o n C o d e B u i l d i n g F e a t u r e s Ce i l i n g F l a t : R - 3 8 . 0 D u c t L e a k a g e t o O u t s i d e : 0 . 0 0 C F M @ 2 5 P a s c a l s Se a l e d A t t i c : N A T o t a l D u c t L e a k a g e : 1 8 9 . 0 0 C F M @ 2 5 P a s c a l s Va u l t e d C e i l i n g : N A I n f i l t r a t i o n : H t g : 2 8 7 5 C l g : 2 8 7 5 C F M 5 0 Ab o v e G r a d e W a l l s : R - 1 6 . 5 W i n d o w : U - V a l u e : 0 . 2 9 0 , S H G C : 0 . 2 6 0 Fo u n d a t i o n W a l l s : R - 1 0 . 0 H e a t i n g F u e l - f i r e d a i r d i s t r i b u t i o n , N a t u ra l g a s , 9 7 . 0 A F U E . Ex p o s e d F l o o r : R - 3 8 . 5 C o o l i n g A ir c o n d i t i o n e r , E l e c t r i c , 1 6 . 5 SE E R . Sl a b : R - 0 . 0 E d g e , R - 0 . 0 U n d e r W a t e r H e a t i n g C o n v e n t i o n a l , N a t u r a l ga s , 0 . 5 8 E F , 7 5 . 0 G a l . Du c t : R - 6 . 0 09 - 3 0 - 2 0 1 6 Th e o r g a n i z a t i o n b e l o w c e r t i f i e s t h a t t h e p r o p o s e d b u i l d i n g d e s ig n d e s c r i b e d h e r e i n i s c o n s i s t e n t w i t h t h e b u i l d i n g p l a n s , s p e ci f i c a t i o n s , a n d o t h e r ca l c u l a t i o n s s u b m i t t e d w i t h t h e p e r m i t a p p l i c a t i o n . T h e p r o p o s e d b u i l d i n g h a s b e e n d e s i g n e d t o m e e t t h e 2 0 0 9 I E C C r e q u i r e m e n t s i n c o m p l i a n c e w i t h Ch a p t e r 4 b a s e d o n C l i m a t e Zo n e 5 A a n d w i t h a l l m a n d a t o r y r e q u i r e m e n t s . Na m e : MI C H A E L H I L L S i g n a t u r e : Or g a n i z a t i o n : TS I E N E R G Y S O L U T I O N S D a t e : Se p t e m b e r 3 0 , 2 0 1 6 T h e 2 0 0 9 I n t e r n a t i o n a l E n e r g y C o n s e r v a t i o n C o d e i s a r e g i s t e r e d t r a d e m a r k o f t h e I n t e r n a t i o n a l C o d e C ou n c il , I n c . ( “ I C C ” ) . No v e r s i o n o f t h i s s o f t w a r e h a s b e e n r e v i e w e d o r a p p r o v e d b y I C C o r i t s a f f i l i a t e s . RE M / R a t e - R e s i d e n t i a l E n e r g y A n a l y s i s a n d R a t i n g S o f t w a r e v 1 5 . 1 RESNET HOME ENERGY RATING Standard Disclosure For home located at:10540 HUSSEY LN City:CARMEL (AS BUILT)State:IN 1.X The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 2.X In addition to the rating, the Rater or Rater's employer has also provided the following consulting services for this home: A. Mechanical system design B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself X D. Training for sales or construction personnel E. Other (specify below) 3.The Rater or Rater's employer is: A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home C.An employee, contractor or consultant of the electric and/or natural gas utility serving this home 4.X The Rater or Rater's employer is a supplier or installer of products, which may include: Installed in this home by: OR Is in the business of: HVAC systems Rater Employer Rater Employer Thermal insulation systems Rater Employer Rater Employer Air sealing of envelope or duct systems Rater Employer Rater X Employer Windows or window shading systems Rater Employer Rater Employer Energy efficient appliances Rater Employer Rater Employer Construction (builder, developer, construction Rater Employer Rater Employer contractor, etc.) Other (specify below):Rater Employer Rater Employer I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). The nati onal rating quality control provisions of the rating standard are contained in Chapter One 4.C.8. of the standard and are posted at http://resnet.us/standards/RESNET_Mortgage_Industry_Natio The Home Energy Rating Standard Disclosure for this home is available from the rating provider. MICHAEL HILL 9479271 Rater's Printed Name Certification # September 30, 2016 Rater's Signature Date RESNET Form 0300-2