HomeMy WebLinkAboutE001 00 ELEVTRICAL LEGEN AND ABB.pdfFEEDER TAG - SEE FEEDER SCHEDULE CONDUIT TURNED UP CONDUIT TURNED DOWN ABBREVIATION DESCRIPTION: A/AMP AMPERE AFCI ARC FAULT INTERRUPTER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHJ AUTHORITY HAVING JURISDICTION AL ALUMINUM ANSI AMER. NATIONAL STANDARDS INSTITUTE ASA AMERICAN STANDARDS ASSOCIATION ASTM AMER. SOCIETY OF TESTING MATERIALS AWG AMERICAN WIRE GAUGE AT AMPERE TRIP ATS AUTOMATIC TRANSFER SWITCH BL BLANK BKR BREAKER C CONDUIT CB, C/B CIRCUIT BREAKER CKT BKR - CKT CIRCUIT CCTV CLOSED CIRCUIT T.V. CLG CEILING CO CONVENIENCE OUTLET CONN CONNECTION CU COPPER DB DIRECT BURIAL DISC DISCONNECT DN DOWN DWG DRAWING EA EACH E.C.ELECTRICAL CONTRACTOR EF EXHAUST FAN EH ELECTRIC HEAT EIA ELECTRONIC INDUSTRIES ASSOC. EMT ELECTRIC METALLIC TUBING XP EXPLOSION PROOF E, EM EMERGENCY ELEC ELECTRIC EMT ELECTRIC METALLIC TUBING EQ/EQPM EQUIPMENT EUH ELECTRIC UNIT HEATER EWC ELECTRIC WATER COOLER EX EXISTING F FIXTURE FA FIRE ALARM FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FCU FAN COIL UNIT FDR FEEDER FIXT FIXTURE FL FLOOR FLUOR FLUORESCENT FSS FUSED SAFETY SWITCH FT FEET G, GND,GRD GROUND GC GENERAL CONTRACTOR GEN GENERATOR GFI GROUND FAULT INTERRUPTER GTB GROUND TERMINAL BOX HID HIGH INTENSITY DISCHARGE HP HORSE POWER HPF HIGH POWER FACTOR HR HOMERUN HTR HEATER HVAC HEATING, VENTILATION, AIR CONDITIONING CONTRACTOR HV HIGH VOLTAGE HZ HERTZ ICEA INTERNATIONAL CABLE ENGINEERS ASSO. IEEE INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS IES ILLUMINATING ENGINEERING SOCIETY IN INCH INCAN INCANDESCENT IR INFRA-RED JB/JBOX JUNCTION BOX K THOUSAND KVA KILOVOLT-AMPERE KW KILOWATT KWH KILOWATT HOUR LA LIGHTING ARRESTER LCP LIGHTING CONTROL PANEL LED LIGHT EMITTING DIODE LTS LIGHTS LTG LIGHTING LV LOW VOLTAGE MC METAL CLAD M.C.MECHANICAL CONTRACTOR MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MFR MANUFACTURER MH MANHOLE MLO MAIN LUGS ONLY MISC.MISCELLANEOUS MTD MOUNTED MTG HGT MOUNTING HEIGHT MTR MOTOR 1.ALL ELECTRICAL WORK SHALL BE IN ACCORD WITH ALL APPLICABLE ORDINANCES, CODES AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION. ALL ELECTRICAL WORK SHALL BE INSPECTED AND APPROVED BY THE LOCAL ELECTRICAL INSPECTION AGENCY. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY FEES AND PERMITS, INCLUDING THE CERTIFICATE OF ELECTRICAL INSPECTION. 2.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTION SAFETY. ARCHITECT AND/OR ENGINEER SHALL ASSUME NO RESPONSIBILITY FOR WORKMAN'S, OR PEDESTRIAN'S SAFETY. NOTHING IN THE CONTRACT DOCUMENTS SHALL BE CONSTRUED TO INSTRUCT PROCEDURES OR COMPONENTS FOR PROJECT SAFETY. 3.WHERE A CONFLICT ARISES BETWEEN PLANS, SPECIFICATIONS, DETAILS, SCHEDULES, APPLICABLE CODES OR REGULATIONS, THE MOST STRINGENT SHALL APPLY. 4.NOTHING CONTAINED IN THE CONTRACT DOCUMENTS SHALL BE CONSTRUED TO CONFLICT WITH ANY NATIONAL, STATE, MUNICIPAL, OR LOCAL LAWS OR REGULATIONS GOVERNING THE WORK INDICATED OR SPECIFIED. THE ELECTRICAL CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER SHALL SATISFY ALL SUCH REQUIREMENTS. 5.THE CONTRACT DOCUMENTS ARE COMPRISED OF DRAWINGS AND SPECIFICATIONS. EACH ELECTRICAL BIDDER SHALL VISIT SITE TO DETERMINE EXISTING CONDITIONS PRIOR TO SUBMITTING BID PROPOSAL. BIDS SHALL BE BASED ON THE COMPLETE EXAMINATION OF THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS. NO CONSIDERATION WILL BE GIVEN ANY CONTRACTOR WHO FAILS TO DO SO. 6.THE WORK UNDER THIS CONTRACT SHALL INCLUDE THE FURNISHING OF ALL NECESSARY MATERIALS, TOOLS, AND LABOR FOR A COMPLETE, AND WORKING INSTALLATION AS DEFINED BY THE PLANS AND SPECIFICATIONS. THE ELECTRICAL CONTRACTOR SHALL WARRANT THE WORK INDICATED AND SPECIFIED FOR A PERIOD OF ONE YEAR. THE WORK SHALL FUNCTION AS INTENDED, BE COMPLETE IN ALL DETAILS, AND SHALL INCLUDE ALL INDICATED, SPECIFIED, OR REQUIRED ACCESSORIES FOR A FUNCTIONING SYSTEM. 7.THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY LIGHT AND POWER AS REQUIRED BY THE GENERAL CONDITIONS OF THE SPECIFICATION. 8.THE ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES. ALL DEVICES PROVIDED BY OTHERS THAT REQUIRE LINE VOLTAGE ELECTRICAL POWER SHALL BE CONNECTED BY THE ELECTRICAL CONTRACTOR. POWER, PHONE, DATA, TV, AND SIMILAR DEVICE OUTLET LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECTURAL INTERIOR LAYOUTS, THE GENERAL CONTRACTOR, AND THE OWNER. 9.THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OWNER'S PROJECT MANAGER PRIOR TO AND FOR SCHEDULING ANY INTERRUPTION OF ANY BUILDING UTILITY. 10.THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE LOCAL UTILITIES AND ARRANGE FOR THE FOLLOWING SERVICES: ELECTRICAL POWER, CABLE TV, AND TELEPHONE SERVICE. THE ELECTRICAL CONTRACTOR SHALL MEET WITH THE REPRESENTATIVES OF THE ELECTRICAL UTILITY & COMCAST TO CONFIRM DETAILS ON THE SERVICE AND METERING. THE ELECTRICAL CONTRACTOR SHALL PAY ALL NECESSARY COSTS, FEES, AND PERMITS INVOLVED IN BRINGING SERVICE TO THE BUILDING. 11.THE ELECTRICAL CONTRACTOR AT THE SITE SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PERTAINING TO THE INSTALLATION OF THE ELECTRICAL SYSTEMS. WHERE A CONTRACTOR UNCOVERS CONDITIONS NOT INDICATED ON THE PLANS OR IN THE SPECIFICATIONS, HE SHALL NOTIFY THE ARCHITECT PRIOR TO PROCEEDING WITH ANY WORK. FAILURE TO NOTIFY THE ARCHITECT WILL MAKE THE CONTRACTOR RESPONSIBLE FOR ALL COSTS AND CONSEQUENCES OF SUCH FAILURE. 12.THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND REPRESENT THE DESIGN/LAYOUT INTENT ONLY. THE ELECTRICAL CONTRACTOR SHALL DETERMINE CIRCUITING, ROUTING, WIRING ETC.., AS REQUIRED BY THE SITE CONDITIONS, AND ALL APPLICABLE CODES. 13.ALL WIRING SHALL BE CONCEALED IN FINISHED AREAS AS SPECIFIED. WHERE PERMITTED IN THE SPECIFICATIONS, USE OF MC CABLE IN CONCEALED AREAS SHALL BE PER N.E.C., LOCAL CODES, AND INSPECTION AGENCY APPROVAL. OTHERWISE, USE EMT CONDUIT, MINIMUM 3/4" UNLESS NOTED OR SPECIFIED OTHERWISE. 14.THE FOLLOWING CONDUCTORS SHALL BE RUN IN HEAVY WALL CONDUIT: 14.1.ALL FEEDERS RUN IN SLAB - MAY BY SCHEDULE 40 PVC. 14.2.WHERE REQUIRED BY THE N.E.C. 14.3.EXPOSED WIRING ON A ROOF - SEAL PROPERLY. 14.4.EXTERIOR, ABOVE GRADE WIRING. 15.FOLLOWING FEEDERS SHALL BE IN EMT: 15.1.BRANCH FEEDERS TO PANELS. 15.2.BRANCH RACEWAY RUN EXPOSED. 16.TRENCHING AND BACKFILL FOR UNDERGROUND CONDUITS SHALL BE BY THE ELECTRICAL CONTRACTOR. 17.UPON THE COMPLETION OF WORK THE E.C. SHALL PROVIDE ALL PANELBOARDS WITH TYPED PANEL SCHEDULES TO CLEARLY DEFINE THE EQUIPMENT SERVED. 18.UPON THE COMPLETION OF WORK THE E.C. SHALL PROVIDE ALL DISTRIBUTION EQUIPMENT WITH TYPED NAMEPLATES TO CLEARLY DEFINE THE EQUIPMENT SERVED. 19.CHANNELING OF THE FLOORS SHALL BE MINIMIZED. 20.SURFACE PANCAKE RACEWAY IS PROHIBITED. 21.REFER TO REFLECTED CEILING PLANS FOR THE COORDINATED PLACEMENT OF LIGHTS, DIFFUSERS, SPRINKLERS, AND RETURN AIR GRIDS. 22.E.C. SHALL COORDINATE ALL RECEPTACLE AND LIGHT FIXTURES LOCATIONS WITH CASEWORK AND THE OWNERS FIXTURES LAYOUT PLAN WHICH WILL BE DIMENSIONED. 23.ALL HOMERUNS WITH MORE THAN SIX (6) TOTAL CONDUCTORS SHALL BE A MINIMUM OF NO. 10 THWN WIRE UNLESS SPECIFICALLY SIZED OTHERWISE. 24.ALL WORK SHOWN ON THE ELECTRICAL DRAWINGS SHALL BE BY THE ELECTRICAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. 25.CONTRACTOR SHALL REMOVE DEMOLITION DEBRIS COMPLETELY. CONTRACTOR SHALL SCHEDULE WITH THE OWNER THE TIME, LOCATION, ELEVATOR AND HAULING ROUTE. 26.CONTRACTOR SHALL CLEAN UP ALL DEBRIS AT THE END OF EACH WORK DAY. 27.EXACT COUNTS/QUANTITIES FOR CONTRACT PURPOSES SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AND INCLUDED AS PART OF THE BASE BID. 28.REFER TO ARCHITECTURAL DRAWING FOR ALL WALL HEIGHTS. 29.VERIFY EXACT LOCATION OF ALL MECHANICAL EQUIPMENT WITH THE MECHANICAL CONTRACTOR, PRIOR TO ROUGH-IN. E.C. SHALL ALSO INCLUDE COORDINATION WITH DEVICES BY M.C., WIRING REQUIREMENTS, INTERCONNECTIONS, AND TERMINATIONS AND PROVIDE AS REQUIRED. 30.ALL CONDUITS RUN IN EXPOSED AREAS SHALL BE MOUNTED TIGHT TO THE UNDERSIDE OF THE STRUCTURAL STEEL. THIS APPLIES FOR ALL BRANCH CIRCUIT AND FEEDER CONDUITS. 31.ALL HOLES AND OPENINGS CREATED TO EXTEND THE ELECTRICAL SYSTEMS THROUGH FLOORS AND FIRE RATED ASSEMBLIES SHALL BE FIRESTOPPED. 32.DURING THE BIDDING PROCESS, ELECTRICAL CONTRACTOR SHALL REVIEW DRAWINGS AND SPECIFICATIONS OF ALL OTHER TRADES (GENERAL, HVAC, AND PLUMBING). ALL ITEMS REQUIRING POWER INDICATED ON THESE DRAWINGS BUT NOT INDICATED ON THE ELECTRICAL DRAWINGS SHALL BE CONSIDERED A PART OF THE ELECTRICAL CONTRACTORS WORK. THIS WORK SHALL BE INSTALLED AS PER NEC AT NO ADDITIONAL COST TO THE OWNER 33.WHERE CONDUIT SIZES HAVE BEEN OMITTED, THE CONTRACTOR SHALL INSTALL THE CORRECT SIZES REQUIRED BY THE N.E.C. AS DETERMINED BY THE NUMBER OF WIRES TO BE INSTALLED. WHERE THE NUMBER AND OR SIZES OF HAVE BEEN OMITTED, THE CONTRACTOR SHALL INSTALL THE REQUIRED NUMBER AND OR SIZES AS DETERMINED BY THE EQUIPMENT REQUIREMENTS OR FROM ADJACENT SECTIONS AND CIRCUIT NUMBERS. 34.WIRE SIZE FOR BRANCH CIRCUITS SHALL BE ADJUSTED TO COMPENSATE FOR VOLTAGE DROP CALCULATIONS AS REQUIRED BY NEC. IF CIRCUIT RUN EXCEEDS 100FT. IN WIRE LENGTH, NEXT WIRE SIZE (#10) SHALL BE USED. 35.STARTERS, COMBINATION STARTERS, CONTRACTORS, ETC.. FOR MECHANICAL EQUIPMENT SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. ALL POWER WIRING AND CONDUIT TO EQUIPMENT TERMINALS SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. POWER TO MECHANICAL EQUIPMENT SHALL BE TURNED ON ONLY BY THE MECHANICAL CONTRACTOR. MECHANICAL NAME PLATE DATA SHALL NOT BE COVERED BY ELECTRICAL DEVICES. 36.THE ELECTRICAL CONTRACTOR SHALL FURNISH SUBMITTALS IN ACCORD WITH THE SPECIFICATIONS. ALL SUBMITTALS SHALL BE REVIEWED AND STAMPED BY THE ENGINEER PRIOR TO INSTALLATION. 37.THE ELECTRICAL CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS FOR THE ENTIRE PROJECT AS DEFINED IN THE SPECIFICATIONS 38.THIS CONTRACTOR SHALL VISIT THE SITE AND FULLY INFORM HIMSELF OF ALL THE EXISTING CONDITIONS, WHICH IN ANY WAY WILL AFFECT THE EXECUTION OF HIS WORK AND THE REQUIREMENTS OF THIS CONTRACT AS SHOWN OR REASONABLY INFERRED ON THE DRAWINGS AND PRODUCT SPECIFICATIONS. POWER SYMBOLS ELECTRICAL ABBREVIATIONS ELECTRICAL NOTES TOP OF PANELBOARDS, LIGHT FIXTURES PENDANT MOUNTED FIRE ALARM HORNS/STROBES TOP OF DISCONNECT SWITCHES, STARTERS, AND CONTACTORS CABINETS 6'-6" 6'-0" 4'-0" FINISHED FLOOR 2'-0" 3'-6" 1'-6" 0'-0" TOP OF ACTUATING DEVICE ON LIGHT SWITCHES, FIRE ALARM PULL STATIONS, MANUAL MOTOR STARTERS OR PUSH BUTTON CTR COUNTER TOP RECEPTACLE MOUNT CENTER OF RECEPTACLE 6" ABOVE COUNTER TOP OR BACKSPLASH MOUNTING HEIGHT SCHEDULE GENERAL SYMBOLS WALL MOUNTED HANDICAPPED TELEPHONE OUTLETS ELECTRICAL RECEPTACLES IN MECHANICAL/ELECTRICAL ROOMS & ELEVATOR MACHINE ROOMS ELECTRICAL RECEPTACLES (U.N.O.) COMMUNICATIONS/DATA OUTLETS (U.N.O.) EMERGENCY DUPLEX RECEPTACLE SINGLE EXIT SIGN CEILING/WALL MOUNT FACE DIRECTION AS SHOWN BY ARROWS. PROVIDE DIE-CAST ALUMINUM WITH RED LETTERING LED EXIT SIGN, LITHONIA LQC SERIES OR APPROVED EQUAL. COMBINATION MOTOR STARTER FURNISHED BY MC INSTALLED BY EC MOTOR STARTER FURNISHED BY MC INSTALLED BY EC EQUIPMENT CONTROL PANEL FINAL CONNECTION BY EC 2x2 RECESSED FLUORESCENT FIXTURE 2x4 RECESSED FLUORESCENT FIXTURE 4' RECESSED FLUORESCENT FIXTURE STRIP FIXTURE. DOWNLIGHT FIXTURE WALL WASHER FIXTURE WALL MOUNTED FIXTURE TRACK LIGHT FIXTURE. DUPLEX RECEPTACLE SINGLE POLE SWITCH JUNCTION BOX SIMPLEX RECEPTACLE QUAD RECEPTACLE SPECIAL RECEPTACLE NEMA TYPE AS SHOWN WALL FLR CLG NOMENCLATURE: +6" ABOVE COUNTER +48 MOUNTED 48" A.F.F. CR OVERHEAD CORD REEL GFI GROUND FAULT INTERRUPTER IG ISOLATED GROUND TR TAMPER RESISTANT WP WEATHER PROOF #NUMERICAL NUMBER INDICATES THE NUMBER OF DEVICES EMERGENCY QUAD RECEPTACLE FURNITURE FEED UNFUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH CIRCUIT BREAKER RELAY 120/208V ELECTRIC PANEL METER GROUNDING ROD HANDHOLE / MANHOLE NOMENCLATURE: 'P'POWER 'T' TELECOM DEVICE SYMBOL POLE MOUNTED ROUND SITE LIGHTING FIXTURE NUMBER OF HEADS AS SHOWN ON PLANS POLE MOUNTED SQUARE SITE LIGHTING FIXTURE NUMBER OF HEADS AS SHOWN ON PLANS BOLLARD INTERCOM SLAVE INTERCOM MASTER INTERCOM POWER DEVICE KEY INTERCOM SUBSTATION MICROPHONE PUSH BUTTON PUSH BUTTON - 3 POSITION SPECIAL RECEPTACLE NEMA TYPE AS SHOWN PENDANT LIGHT VOICE/DATA OUTLET. PROVIDE 4" SQUARE BOX WITH SINGLE GANG DEVICE BRACKET AND 1" EMT CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING - PROVIDE PULL STRING IN ALL CONDUIT VOICE OUTLET. PROVIDE 4" SQUARE BOX WITH SINGLE GANG DEVICE BRACKET AND 1" EMT CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING - PROVIDE PULL STRING IN ALL CONDUIT DATA OUTLET. PROVIDE 4" SQUARE BOX WITH SINGLE GANG DEVICE BRACKET AND 1" EMT CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING - PROVIDE PULL STRING IN ALL CONDUIT 8' RECESSED FLUORESCENT FIXTURE 2x4 PENDANT MOUNTED FIXTURE 4' PENDANT MOUNTED FIXTURE 2x4 SURFACE MOUNTED FIXTURE 4' SURFACE MOUNTED FIXTURE LIGHTING CONTROL STATION DUAL TECHNOLOGY OCCUPANCY SENSOR CEILING/WALL MOUNTED SWITCH BYPASS DEVICE PHOTO CELL SPLIT WIRED RECEPTACLE JJ TMHPHH R AUXILIARY SOUND SYSTEM SPEAKER PAGING SPEAKER VOLUME CONTROL XX TTB TELEPHONE TERMINAL BOARD, 4' x 8' x 3/4" MARINE GRADE PLYWOOD LIGHTING SYMBOLS NOMENCLATURE - X=: a,b,c DESIGNATES LIGHT FIXTURE CONTROLLED 3 THREE WAY 4 FOUR WAY D DIMMER DT DUAL TECHNOLOGY OCCUPANCY SENSOR E EMERGENCY F FAN K KEY OPERATED LV-x LOW VOLTAGE (x DENOTES SWITCH NUMBER, REFER TO SCHEDULE) MC MOMENTARY CONTACT M MANUAL MOTOR STARTER P PASSIVE INFRARED OCCUPANCY SENSOR T TIME W WET LOCATION OS OCCUPANCY SENSOR OS2 OCCUPANCY SENSOR WITH 2 SWITCHES LINE VOLTAGE OCCUPANCY SENSOR CEILING/WALL MOUNTED COMMUNICATION SYMBOLS WIRING SYMBOLS GND GROUND CABLE UNDER FLOOR OR UNDER GROUND CONDUIT AND WIRING SURFACE CONDUIT AND WIRING WIRING HOMERUN, INDICATES BRANCH CIRCUIT CONDUIT AND WIRE TO PANELBOARD SURFACE RACWAY WITH 20 AMP DUPLEX OUTLETS 120 V SPACED AS INDICATED CONCEALED CONDUIT AND WIRING INDICATES PANEL NAME INDICATES CIRCUIT NUMBER INTERCOM / PAGING SYMBOLS ACCESS CONTROL/SECURITY SYMBOLS WALL MOUNTED CEILING MOUNTED SP IM IS IC I M SP SP V LC SBD PC M CP CB X XXX POWER PACKPP B1-3 XX-XX ABBREVIATION DESCRIPTION: N/A NOT APPLICABLE NC NORMALLY CLOSED NF NON-FUSED SAFETY SWITCH NEC NATIONAL ELECTRIC CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN THIS CONTRACT NM NON-METTALIC NO NORMALLY OPEN NTS NOT TO SCALE OC ON CENTER OEM ORIGINAL EQUIPMENT MANUFACTURER OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION P POLE PBOX PULL BOX PC PHOTOCELL P.C.PLUMBING CONTRACTOR PH / Ø PHASE PNL PANEL POS POSITION PR PRESENT LIGHTING FIXTURE, SWITCH, DEVICE, ETC., TO REMAIN PRI PRIMARY PRN PRESENT LIGHTING FIXTURE, SWITCH, DEVICE, ETC., TO BE REMOVED AND REPLACED WITH NEW PRR PRESENT LIGHTING FIXTURE, SWITCH, DEVICE, ETC., SHOWN AT NEW LOCATION PRX PRESENT LIGHTING FIXTURE, SWITCH, DEVICE, ETC., TO BE REMOVED AND OUTLET BOX EXTENSION INSTALLED FOR SURFACE CONDUIT OR SMR AND WIRE EXTENSION TO NEW OUTLET SHOWN. REINSTALL PRESENT LIGHTING FIXTURE, SWITCH, DEVICE, ETC. PWR POWER REC / RECPT RECEPTACLE RGS RIGID GALVANIZED STEEL RMC RIGID GALVANIZED METAL CONDUIT RPC REMOVE PRESENT FIXTURE, SWITCH, DEVICE, ETC., AND CAP OUTLET. RPP REMOVE PRESENT FIXTURE, SWITCH, DEVICE, ETC., PATCH THE PLASTER IF IN PLASTER: CAP IF IN METAL OR WOOD. RPR REMOVE PRESENT FIXTURE, SWITCH, DEVICE, ETC., TO BE REMOVED AND RELOCATED. RPX REMOVE PRESENT FIXTURE, SWITCH, DEVICE, ETC., WIRE AND ALL RELATED EXPOSED RACEWAY INSOFAR AS IS POSSIBLE. ALL DAMAGED SURFACES TO BE REPAIRED. RT RAIN TIGHT SCHED SCHEDULE SEC SECONDARY SIG SIGNAL SM SURFACE MOUNTED SMR SURFACE MOUNTED RACEWAY SP SPARE SS SAFETY SWITCH SW SWITCH SWBD SWITCHBOARD TEL / TELE TELEPHONE TL TWIST LOCK TP TAMPER PROOF TX / XFMR TRANSFORMER TTB TELEPHONE TERMINAL BOARD TV TELEVISION TYP TYPICAL UH UNIT HEATER UL UNDERWRITERS' LABORATORIES, INC UNO UNLESS NOTED OTHERWISE V VOLTAGE VT VAPOR TIGHT W WIRE; WATT W/WITH W/O WITHOUT WP WEATHER PROOF WT WATER TIGHT REFERENCE LIGHTING FIXTURE SCHEDULE FOR MOUNTING REQUIREMENTS 6'-8" AFF OR 6" BELOW FINISHED CEILING, WHICHEVER IS LOWER (BOTTOM OF LENS; MIN.) 30 3 NF 3R DISCONNECT SWITCH KEY SIZE NO. OF POLES NEMA TYPE FUSED # OR NF LIGHTING FIXTURE KEY Xa XX-XX INDICATES CIRCUIT NUMBER INDICATES SWITCH CONTROL (a) INDICATES FIXTURE TYPE SEE SCHEDULE FOR DESCRIPTION INDICATES PANEL NAME SHADING INDICATES FIXTURE ON EMER. CIRCUIT INTERCOM SPEAKERS OS OS OS OS X LN VOICE/DATA FLOOR BOX - PROVIDE PULL STRING AND CONDUIT TO NEAREST FULL HEIGHT WALL AND ABOVE ACCESSIBLE CEILING. LN DAYLIGHT SENSORD SECURITY PANELSEC DOOR CONTACTDC PANIC/HOLD-UP BUTTON. MOUNT UNDER FACE OF COUNTERPB VIDEO CAMERA FW NOMENCLATURE: FW FIXED WALL MOUNTED VIDEO CAMERA FC FIXED CEILING MOUNTED PTZ-C PAN, TILT, ZOOM CEILING MTD PTZ-W PAN, TILT, ZOOM WALL MTD KEY PADKP MOTION SENSORMS LOCAL ALARMLA CCX INDICATES CONTROL ZONE (REFER TO LD DRAWINGS) X X NOMENCLATURE: B INTERIOR BEAM SPEAKER C INTERIOR CEILING SPEARK O OUTDOOR WET RATED A.ALL WIRING AND PIPING WILL BE SURFACE MOUNTED INSIDE WALK-IN COOLERS AND FREEZERS PENETRATION MUST BE KEPT TO A MINIMUM. ALL CONDUIT PENETRATING WALK-IN UNITS MUST BE SEALED INSIDE THE RACEWAY AS WELL AS OUTSIDE. B.ALL OUTLET COVERS MUST BE TAGGED SHOWING PANEL AND CIRCUIT NUMBERS ALONG WITH THE EQUIPMENT NAME THE RECEPTACLE IS FEEDING. C.ALL OUTLETS CONNECTED TO ISOLATED GROUND PANELS MUST BE ORANGE IG RECEPTACLES. GENERAL NOTES A.GENERALLY, RECEPTACLES SHALL BE MOUNTED AT HEIGHTS AS DESCRIBED BELOW UNLESS SPECIFIC MOUNTING HEIGHTS ARE INDICATED FOR THE RECEPTACLE EITHER IN THE EQUIPMENT SCHEDULES OR ON PLANS. A.A.RECEPTACLES SHOWN WITHOUT NO OTHER MARKINGS SHALL BE 18" AFF. A.B.RECEPTACLES SHOWN WITH A + OR INDICATED TO BE ABOVE COUNTER SHALL BE 48" AFF. B.ON TILE WALLS, IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE ALL RECEPTACLE ROUGH-IN LOCATIONS WITH THE TILE INSTALLER SUCH THAT ALL RECEPTACLES LAND ON GROUT LINES. THE MOUNTING HEIGHTS GIVEN ABOVE MAY NEED TO BE ADJUSTED BY +/- 6" BASED ON THE TILE SIZE. RECEPTACLES SHALL NOT BE MOUNTED ON FINISH TRANSITIONS, I.E. WHERE TILE TERMINATES ON DRYWALL. IN NO INSTANCE SHALL A RECEPTACLE BE MOUNTED BELOW 42" AFF WHEN SHOWN TO BE MOUNTED ABOVE A COUNTER AS 42" IS THE BACKPLASH HEIGHT OF A STANDARD STAINLESS STEEL TABLE. C.ON TILE WALLS, ALL RECEPTACLES SHALL BE MOUNTED HORIZONTALLY. OTHER DEVICES SHALL BE MOUNTED VERTICALLY. D.AT THE CUSTOMER SERVICE COUNTER, ALL RECEPATCLES SHALL BE MOUNTED AT 17" AFF BELOW THE COUNTER. COORDINATE EXACT DIMENSIONS WITH THE MILLWORK SHOP DRAWINGS. E.ALL RECEPTACLES SHOWN MOUNTED ON REFRIGERATED CASES SHALL BE MOUNTED HORIZONTALLY IN THE EQUIPMENT KICKPLATE. F.ALL RECEPTACLES WITH A WP NOTATION SHALL BE WEATHERPROOF, WHILE IN USE. DEVICES SHALL HAVE A MINIMUM INGRESS PROTECTION RATING OF IP25. MOUNT RECEPTACLES IN LOW CAFE EXTERIOR WALL SUCH THAT THE IN-USE COVER IS OPERABLE AND NOT OBSTRUCTED BY THE STONE CAP. COORDINATE MOUNTING HEIGHT WITH MASONRY CONTRACTOR. G.NO ADDITIONAL COST TO ADJUST MOUNTING HEIGHTS OR RELOCATE RECEPTACLES WILL BE PAID TO THE EC IF THE EC DID NO COORDINATE WITH THE TILE INSTALLER OR THE EQUIPMENT CUT SHEETS MADE AVAILABLE BY THE OWNER. RECEPTACLE MOUNTING NOTES TV OUTLET. PROVIDE 4" SQUARE BOX WITH SINGLE GANG DEVICE BRACKET AND 1" EMT CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING - PROVIDE PULL STRING IN ALL CONDUIT TV XX ELECTRICAL LEGEND AND ABBREV. E001 AS NOTED SAS SAS . . . . . REV. NO. SPCR NO. PROJECT LOCATION FILE NAME LAYERS DATE SCALE SHEET NO. DWG. TITLE OWNER USERNAME PROJECT NO. PLANNER KICK OFF MEETING ISSUED FOR 90% ISSUED FOR PERMIT FINAL APPROVED PLAN RECORD DRAWINGS DRAWN BY CHECKED BY GETGO #3557 4927 EAST 146TH STREET 261 KAPPA DRIVE, DATE REVISIONS BY ISSUED FOR REDLINE REVIEW GIANT EAGLE, INC. 750 HOLIDAY DRIVE, SUITE 200 PITTSBURGH, PA 15220 PHONE: 412-921-4300 FAX: 412-921-4313 PITTSBURGH, PA 15238 2016003.00 01-20-15 CARMEL, IN 46062 02-26-16 02-26-16