HomeMy WebLinkAboutE202 01 POWER - HVAC AND REFRIGE.pdfDP-8,10,12 DP-2,4,6 S-22,24 S-26 S-28 S-21,23,25 3 2 4 5 6 7 S-14 S-6 8 9 10 19 20 21 22 S-10 S-16 12 11 1 S-12 13 14 15 16 S-8 17 18 GFI, WP 23 JJ 1 2 GFI, WP CP PROVIDE RS-485 CONTROL WIRING TO RTU-1. T PROVIDE CONTROL WIRING TO RTU-2 - (2)#18 T PROVIDE CONTROL WIRING TO RTU-1 - (2)#18 INTERNAL UNIT FED FROM SSAC-1 REMOTE ALARM PANELS FOR RTU'S. COORDINATE ELECTRICAL CONNECTION WITH MECHANICAL CONTRACTOR H-39 C1 AO AOC1 C1 C1 CONTACTOR OUTPUTS FOR CONTACTORS 'C6' & 'C7' LOCATED IN EMERGENCY LIGHTING CONTACTOR ENCLOSURE EMS CONTACTOR OUTPUTS FOR CONTACTORS 'C1', 'C2', 'C3', 'C4' & 'C5' LOCATED IN POWERWALL C1 C1 C1 C1 C1 EMS AO AO ANALOG OUTPUTS FOR DIMMING MODULES 'DM1', 'DM2' & 'DM3' LOCATED IN NORMAL LIGHTING DIMMING MODULE ENCLOSURE EMS AO AO ANALOG OUTPUT FOR DIMMING MODULE 'DM4' LOCATED IN EMERGENCY LIGHTING DIMMING MODULE ENCLOSURE EMSBM1 BM1 BM1 BM1 3 3 PCEMS E-009 E702 BM1 4 PC EM S BM1 4 2P-30A MANUAL STARTER SWITCH IN WP ENCLOSURE. MOUNT TO BACKSIDE OF EVAPORATOR. WIRE THROUGH EVAPORATOR C-31 24 27 29 28 M M 5 26 25 6 WK100 A D T 1 4 0 A D T 1 4 0 LE T 0 9 0 S3 S9 S1 S3 S3 E E E S E S S1 E M M M M EF-1 RTU-1 EF-2 SSAC-1 RTU-2 6 78 S-19 C-29 GFI,WP J 7 J 7 J 1 2 3 E1E2 XX POWER - HVAC AND REFRIGERATION E202 AS NOTED SAS SAS . . . . . SCALE: POWER - MECHANICAL AND REFRIGERATION PLAN 3/16" = 1'-0"1 PROVIDE 8"x8"x4" JUNCTION BOX BELOW ROOF FOR REFRIGERATION POWER CIRCUITS (208/120V). EXTEND (1) 2" CONDUIT THROUGH ROOF TO REFRIGERATION CONTROL PANEL. PROVIDE 8"x8"x4" JUNCTION BOX BELOW ROOF FOR REFRIGERATION SIGNAL CIRCUITS (LOW VOLTAGE). EXTEND (1) 2" CONDUIT THROUGH ROOF TO REFRIGERATION CONTROL PANEL. CONTACTOR OUTPUT FOR LIGHTING CONTACTOR NOTED. PROVIDE (3) #12, 3/4"C. EACH. E.C. TO PROVIDE PILOT RELAYS AS REQUIRED FOR 120V WIRING CONNECTIONS TO 24V CONTACTS ON BMS CPC CONTROLLER I/0 BOARDS. MOUNT RELAYS AT RESPECTIVE CONTACTORS. WIRE FOR PHOTOCELL FROM EMS I/O BOARD TO MOUNTING LOCATION. ROUTE CONDUIT TO GRAB N GO CASE TO NEAREST FULL HEIGHT WALL ALONGSIDE REFRIGERATION PIPING. PROVIDE DELTA-THERM DTC-24R ROOF DE-ICE CONTROL IN MOUNTED TO PARAPET. PLUG POWER SUPPLY INTO ADJACENT RECETPACLE. PROVIDE CLASS TWO WIRING TO ADJACENT CONTACTOR. MOUNT TEMPERATURE/MOISTURE SENSOR ADJACENT TO CONTROL. REFER TO MANUFACTURER INSTALLATION INSTRUCTION. PROVIDE CONTINUOUS DELTA-THERM TYPE MI DE-ICE CABLE AS INDICATED ON THE ROOF AT EACH SCUPPER AND LOOP IN 12' DOWNSPOUTS. PROVIDE 120V/10W PER LINEAR FOOT. FEED FROM 30A CONTACTOR. PROVIDE ALL MOUNTING HARDWARE PER MANUFACTURER RECOMMENDATIONS. PROVIDE 240V-30A CONTACTOR WITH 24V COIL IN NEMA 3R ENCLOSURE FOR ROOF DE-ICE SYSTEM. CONTROL VIA DTC-24R CONTROL PANEL TO FEED DE-ICE CABLE. KEY NOTES 1 2 GENERAL NOTES 1.REFER TO REFRIGERATION DRAWINGS R-101 AND R-201 FOR EQUIPMENT LOCATIONS AND CONNECTION DETAILS. 2.REFER TO DETAIL 2 ON DRAWING E701 FOR TEMPERATURE SENSOR MOUNTING. 3.REFER TO DETAIL 14 ON E702 FOR FREEZER ALARM WIRING. 4.EMS WIRING CANNOT SHARE RACEWAY WITH POWER WIRING 5.WEATHERPROOF RECEPTACLES AND HACR RATED DISCONNECT SWITCHES SHALL BE FURNISHED PRE-WIRED WITH THE RTU'S UNO. 6.RTU EMS CONTROL PANELS SHALL BE FACTORY INSTALLED UNO. 7.REFER TO REFRIGERATION DRAWINGS FOR ADDITIONAL REQUIREMENTS FOR EMS WIRING. ALL EMS CABLE SHALL BE RUN CONTINUOUS WITH NO SPLICES. 8.EC SHALL SEAL AIR TIGHT ALL PENETRATIONS WHERE WIRING AND CONDUIT PASSES THROUGH OR INTO COOLERS AND FREEZERS. 9.ALL CABLING TO BE IN CONDUIT CONCEALED ABOVE CASES, IN WALLS AND ABOVE CEILINGS. 10.ALL CONDUITS ARE TO BE RUN AS HIGH AS POSSIBLE THROUGHOUT SALES AREA AND ANY AREAS THAT ARE OPEN TO PUBLIC VIEW. ALL CONDUITS WHICH ARE TO BE SUPPORTED FROM THE STRUCTURE ABOVE, SHALL BE SUPPORTED FROM THE TOP CORD OF STRUCTURAL JOIST ONLY. NO CONDUITS SHALL BE SUPPORTED FROM BOTTOM CORD OF JOISTS OR ROOF DECK. ADDITIONALLY, NO CONDUITS SHALL BE MOUNTED ABOVE THE TOP OF THE BOTTOM CORD OF THE JOIST. IN NO CASE SHALL CONDUIT BE ROUTED BETWEEN ROOF DECK AND TOP CORD OF JOIST. NO FLEX CONDUIT OR MC CABLE SHALL BE USED THROUGHOUT THE SALES AREA AND ANY AREAS THAT ARE OPEN TO PUBLIC VIEW, UNO. 3 X REFRIGERATION EQUIPMENT ELECTRICAL CONNECTION SCHEDULE TAG EQUIPMENT DESCRIPTION WIRE TO WIRE/CONDUIT 1 REFRIGERATION CONTROL PANEL 23 4#1 & 1 #8G-1-1/4"C. 2 FREEZER EVAPORATOR 1 2 #12 & 1 #12G-3/4"C. 3 FREEZER DEFROST 1 2 #12 & 1 #12G-3/4"C. 4 FREEZER TEMP SENSOR 1 2 #18-1/2"C. 5 FREEZER LIQUID LINE SOLENOID 1 2 #12 & 1 #12G-3/4"C. 6 DAC-55 DOOR SENSOR (POWER)HR 2 #12 & 1 #12G-3/4"C. 6 DAC-55 DOOR SENSOR (DATA)1 2 #18-1/2"C. 7 FREEZER MAG LOCK 6 2 #18-1/2"C. 8 COOLER EVAPORATOR HR 2 #12 & 1 #12G-3/4"C. 9 COOLER EECV*1 (4)CONDUCTOR #14 CABLE** 10 COOLER TEMPERATURE SENSOR 1 2 #18-1/2"C. 11 RGD EECV*1 (4)CONDUCTOR #14 CABLE** 12 RGD TEMP SENSOR 1 2 #18-1/2"C. 13 BEER CAVE EVAPORATOR HR 2 #12 & 1 #12G-3/4"C. 14 BEER CAVE TEMP SENSOR 1 2 #18-1/2"C. 15 BEER CAVE EECV*1 (4)CONDUCTOR #14 CABLE** 16 COOLER EECV*1 (4)CONDUCTOR #14 CABLE** 17 COOLER EVAPORATOR HR 2 #12 & 1 #12G-3/4"C. 18 COOLER TEMPERATURE SENSOR 1 2 #18-1/2"C. 19 CPC CONTROLLER (POWER)HR 2 #12 & 1 #12G-3/4"C. 20 CPC CONTROLLER (DATA)1 RS485 CABLE 21 CPC ALARM (POWER)HR 2 #12 & 1 #12G-3/4"C. 22 CPC ALARM (DATA)20 CAT 5E 23 DISCONNECT FOR REFRIGERATION SKID HR 4#1 & 1 #8G-1-1/4"C. 24 PARASENSE LEAK DETECTION PANEL POWER HR 2 #12 & 1 #12G-3/4"C. 25 PARASENSE LEAK DETECTION PANEL SIGNAL 1 2 #18-1/2"C. 26 PARASENSE LEAK DETECTION BEACON SOUNDER 24 2 #18-1/2"C. 27 BEER CAVE LIQUID LINE SOLENOID 1 2 #12 & 1 #12G-3/4"C. 28 GRAB 'N' GO EECV*1 (4)CONDUCTOR #14 CABLE** 29 GRAB 'N' GO TEMP SENSOR 1 2 #18-3/4"C. *EECV - ELECTRIC EVAPORATOR CONTROL VALVE ** CONDUCTOR INSULATION COLORS TO MATCH WHIP FROM VALVE (BLACK, RED, GREEN, WHITE). PROVIDE OLYMPIC CABLE #2344 OR EQUAL. 8 DO w/overrides 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 4 AO 1.1 1.2 1.3 1.4 8 D/O w/overrides 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 NO NO NO NO NO NO NO NO/NC AO AO AO AO NO NO NO NO NO NO NO NO C1 C2 C3 C4 C5 C6 C7 DM1 DM2 DM3 DM4 LIGHTING CONTACTOR LIGHTING CONTACTOR LIGHTING CONTACTOR LIGHTING CONTACTOR LIGHTING CONTACTOR LIGHTING CONTACTOR LIGHTING CONTACTOR SPARE LIGHTING DIMMING ZONE LIGHTING DIMMING ZONE LIGHTING DIMMING ZONE LIGHTING DIMMING ZONE FAN HEAT STAGE 1 HEAT STAGE 2 COMPRESSOR COOL STAGE 1 COMPRESSOR COOL STAGE 2 ALARM BMS CPC ENCLOSURE 'BM1' - SUPPLIED BY REFRIGERATION CONTRACTOR 88AO Module #1 Combination 8DI/AI / 8DO / 4AO Module RTU #1 BOARD - SUPPLIED BY OEM MULTIFLEX RCB Module #1 Combination 8DI/AI / 8DO Module 8 DI / AI 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 8 DI 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 DI DI AI/DI AI/DI AI/DI AI/DI AI/DI AI/DI DI DI PC PC EXTERIOR PHOTOCELL INTERIOR PHOTOCELL SPARE SPARE SPARE SPARE SPARE SPARE SUPPLY DUCT TEMP SENSOR RETURN AIR TEMP SENSOR COMP 1 PROOF COMP 2 PROOF AIRFLOW ENTHALPY SWITCH SPACE HUMIDITY 1.9 1.10 NO/NC NO/NC SPARE 1.9 1.10 AI/DI AI/DI SPARE SPARE DEHUMIDIFICATION ECONOMIZER SPARE SPACE TEMP SENSOR DI DI DI DI DI DI 8 D/O w/overrides 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 NO NO NO NO NO NO NO NO FAN HEAT STAGE 1 HEAT STAGE 2 COMPRESSOR COOL STAGE 1 COMPRESSOR COOL STAGE 2 ALARM RTU #2 BOARD - SUPPLIED BY OEM MULTIFLEX RCB Module #1 Combination 8DI/AI / 8DO Module 8 DI 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 DI DI SUPPLY DUCT TEMP SENSOR RETURN AIR TEMP SENSOR COMP 1 PROOF COMP 2 PROOF AIRFLOW ENTHALPY SWITCH SPACE HUMIDITY 1.9 1.10 NO/NC NO/NC SPARE 1.9 1.10 AI/DI AI/DI SPARE SPARE DEHUMIDIFICATION ECONOMIZER SPARE SPACE TEMP SENSOR DI DI DI DI DI DI CONTACTOR CONTROL SCHEDULE CONTRACTOR DESIGNATION LOAD TO BE CONTROLLED CONTROL SCHEME C1 SITE/FUEL CANOPY LIGHTING TURN ON AND OFF WITH EXT. PHOTOCELL C2 SITE SIGNAGE TURN ON AND OFF WITH EXT. PHOTOCELL C3 SITE PRICING SIGNAGE TURN ON AND OFF WHEN STOREE IS CLOSED - COORDINATE WITH CONSTRUCTION PROJECT MANAGER C4 INTERIOR AREA TURN ON AND OFF WHEN STOREE IS CLOSED - COORDINATE WITH CONSTRUCTION PROJECT MANAGER C5 INTERIOR SALES/RESTROOM TURN ON AND OFF WHEN STOREE IS CLOSED - COORDINATE WITH CONSTRUCTION PROJECT MANAGER C6 INTERIOR EMERGENCY TURN ON AND OFF WHEN STOREE IS CLOSED - COORDINATE WITH CONSTRUCTION PROJECT MANAGER C7 EXTERIOR EMERGENCY TURN ON AND OFF WITH EXT. PHOTOCELL 1.MECHANICALLY HELD CONTACTORS IN FIELD WILL CHANGE STATE WHEN CONTROL DRY CONTACT IN THE BMS SYSTEM 1. SENDS A SIGNAL OR STOPS SENDING A SIGNAL. COIL POWER TO BE ON EMERGENCY POWER. IN THE EVENT OF A POWER FAILURE OR THE BMS SYSTEM BEING REBOOTED FOR ANY REASON, ALL 2.CONTACTOR-CONTROLLED LIGHTING TURNS ON REGARDLESS OF INITIAL STATE. R.C. SHALL CLOSELY COORDINATE CONTACTOR AND RELAY WIRING REQUIREMENTS WITH E.C. TO ACCOMPLISH THE AFORE MENTIONED CONTROL SEQUENCE. PROVIDE ALL LOW VOLTAGE WIRING MODIFICATIONS AS REQUIRED. CONTACTOR CONTROL NOTES: 4 5 6 7 8 REV. NO. SPCR NO. PROJECT LOCATION FILE NAME LAYERS DATE SCALE SHEET NO. DWG. TITLE OWNER USERNAME PROJECT NO. PLANNER KICK OFF MEETING ISSUED FOR 90% ISSUED FOR PERMIT FINAL APPROVED PLAN RECORD DRAWINGS DRAWN BY CHECKED BY GETGO #3557 4927 EAST 146TH STREET 261 KAPPA DRIVE, DATE REVISIONS BY ISSUED FOR REDLINE REVIEW GIANT EAGLE, INC. 750 HOLIDAY DRIVE, SUITE 200 PITTSBURGH, PA 15220 PHONE: 412-921-4300 FAX: 412-921-4313 PITTSBURGH, PA 15238 2016003.00 01-20-15 CARMEL, IN 46062 02-26-16 02-26-16 1 106-17-16 BULLETIN #2 JDF