Loading...
HomeMy WebLinkAboutE203 02 LOW VOLTAGE ROUGH IN - F.pdf1 2 2 3 3 3 3 3 4 TT B 3 3 3 2 2 3 3 PB PB PB PB DC LA PB P B P B IC MS MS PB M SP V V V SP SP SP SP SP SP SP 3 TV TV TV T V TV R-27 3 1 2 43 4 5 6 3 7 9 8 10 11 12 13 18 42 41 40 38 39 34 33 35 1A 36 37 19 20 21 22 23 24 25 26 15 14 17 16 28 27 30 31 32 J J 6 6 B CA D E1 E2 1 2 3 XX LOW VOLTAGE ROUGH IN - FLOOR PLAN E203 AS NOTED SAS SAS . . . . . SCALE: LOW VOLTAGE ROUGH IN - FLOOR PLAN 3/16" = 1'-0"1 PROVIDE (2)2" C. BELOW SLAB. STUB UP 1" ON BOTH SIDES OF SAFE FOR ROUTING CABLING BEYOND SAFE. E.C. SHALL PROVIDE 3/4" CONDUIT PENTRATION THROUGH COOLER / FREEZER WALL FOR CCTV CAMERA WIRING. FOAM SEAL AROUND CONDUIT WHERE IT ENTERS WALL OF COOLER / FREEZER. FOAM SEAL INSIDE OF CONDUIT FOLLOWING CABLE PULL BY CCTV VENDOR. E.C. SHALL PROVIDE 3/4" CONDUIT STUB THROUGH EXTERIOR WALL FOR CCTV CABLING. CAMERA AND CABLING SHALL BE PROVIDED BY VENDOR. SEAL INSIDE AND OUTSIDE OF CONDUIT FOLLOWING CABLE PULL BY CCTV VENDOR. PROVIDE WIRING FROM HOOD ANSUL SYSTEM BACK TO SECURITY CONTROL PANEL PER MANUFACTURER'S REQUIREMENTS. COORDINATE ALARM OPERATION WITH LOCAL AHJ. PROVIDE 6" PVC PIPE SUSPENDED FROM BOTTOM CHORD OF TRUSS TO THE EXTENT INDICATED FOR ROUTING OF SODA LINES. REFER TO DETAIL 2, THIS DRAWING. PROVIDE 4" SQUARE JUNCTION BOX WITH (1) 1" AND (1) 3/4" EMT CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING. PROVIDE 3/4" LIQUID TIGHT FLEXIBLE METAL CONDUIT FROM JUNCTION BOX TO CABLE CONNECTION PLATE ON ATM. PROVIDE PULL STRING IN ALL CONDUITS. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER REPRESENTATIVE. PROVIDE A COMPLETE AND OPERATIONAL SYSTEM. FOR FUTURE ATM, DO NOT PROVIDE LIQUID TIGHT FLEXIBLE METAL CONDUIT AND PROVIDE BLANK COVER PLATE ON JUNCTION BOX. KEY NOTES 1 2 GENERAL NOTES CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE SECURITY SYSTEM. COORDINATE AND ARRANGE A SITE VISIT WITH THE LOSS PREVENTION VENDOR. CONTACT GIANT EAGLE LOSS PREVENTION TO COORDINATE PURCHASE OF THE SECURITY SYSTEM PACKAGE. CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE CCTV CAMERA SYSTEM. COORDINATE AND ARRANGE A SITE MEETING WITH THE CCTV VENDOR. CONTACT GIANT EAGLE PROJECT MANAGER TO COORDINATE PURCHASE OF THE CCTV SYSTEM PACKAGE. 1. 2. SECURITY ALARM NOTES ALL SECURITY ALARM WIRING SHALL BE IN CONDUIT WHERE EXPOSED IN STOCK AND EQUIPMENT ROOM. USE PLENUM RATED CABLE EXPOSED ABOVE LAY-IN CEILINGS WHETHER SPACE IS USED AS RETURN AIR OR NOT. WIRE TYPE AND SIZE SHALL BE AS REQUIRED BY THE SYSTEM MANUFACTURER. THE WIRING SYSTEM SHALL BE CARRIED THROUGH ALL EQUIPMENT, NO PIGTAIL TYPE (TEE) CONNECTIONS SHALL BE ALLOWED DUCT DETECTORS SHALL BE 24VDC ALL FINAL TESTING AND FINAL CONNECTIONS SHALL BE BY LOSS PREVENTION VENDOR. COORDINATE THE QUANTITY, LOCATION & WIRING OF ALL MECHANICAL DUCT SMOKE DETECTORS WITH MECHANICAL ENGINEER. ALL CONDUITS ARE TO BE RUN AS HIGH AS POSSIBLE THROUGHOUT SALES AREA AND ANY AREAS THAT ARE OPEN TO PUBLIC VIEW. ALL CONDUITS, WHICH ARE TO BE SUPPORTED FROM THE STRUCTURE ABOVE, SHALL BE SUPPORTED FROM TOP CORD OF STRUCTURAL JOIST ONLY. NO CONDUITS SHALL BE SUPPORTED FROM BOTTOM CORD OF JOISTS OR ROOF DECK. ADDITIONALLY, NO CONDUITS SHALL BE MOUNTED ABOVE THE BOTTOM OF THE TOP CORD OF THE JOIST. IN NO CASE SHALL CONDUITS BE ROUTED BETWEEN ROOF DECK AND TOP CORD OF JOIST. NO FLEX CONDUIT OR MC CABLE TO BE USED THROUGHOUT SALES AREA AND ANY AREAS THAT ARE OPEN TO PUBLIC VIEW, UNLESS NOTED OTHERWISE ON PLANS. 1. 2. 3. 4. 5. 6. 7. SECURITY WIRING LEGEND 22AWG/4C STRANDED/JACKETED, BELDEN CAT. NO. 88444 (PLENUM) OR CAT NO 8444 (NON-PLENUM IN CONDUIT ONLY ·DOOR CONTACTS ·HOLDUP ALARMS ·SIRENS ·ANNUNCIATOR KEYPADS ·ANNUNCIATED DOOR ALARM ·GLASS BREAKS ·MOTION DETECTORS ·LOCAL ALARMS 22AWG/12C STRANDED/JACKETED, BELDEN CAT. NO 82743 (PLENUM) OR CAT. NO 8747 (NON-PLENUM IN CONDUIT ONLY) ·KEY PADS A. B. CCTV GENERAL NOTES E.C. SHALL PROVIDE BRIDAL RINGS FOR CCTV CABLING FOR CAMERAS. CABLING SHALL BE ROUTED FROM CAMERA LOCATION BACK TO CCTV HEADEND LOCATED IN MANAGER'S OFFICE. CCTV CABLING SHALL BE FURNISHED WITH CCTV VENDOR PACKAGE AND INSTALLED BY CCTV VENDOR. COORDINATE BRIDAL RING INSTALLATION LOCATIONS WITH CCTV VENDOR. 1. 3 LOW VOLTAGE GENERAL NOTES FOR ALL LOW VOLTAGE DEVICES LOCATED ALONG THE EXTERIOR WALL WITH GLASS ABOVE THE DEVICE, ALL WIRING SHALL BE ROUTED FROM TRUSSES ABOVE CONCEALED IN THE MULLION. E.C. SHALL COORDINATE WITH G.C. THAT ACCESSIBLE ROUTING PATHS ARE AVAILABLE TO ALL DEVICE LOCATIONS FOR LOW VOLTAGE VENDORS TO RUN THEIR CABLING. 1. CCTV CAMERA LISTING CAM #DEPARTMENT CAM TYPE CABLE TYPE REMARKS 1 EXTERIOR AXIS P1427-LE 15' CAT 6 13'-6" HEIGHT OR ABOVE AWNINGS 2 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER AWNINGS WHEN APPLICABLE) 3 EXTERIOR AXIS P1427-LE 15' CAT 6 12' HEIGHT OR ABOVE AWNINGS 4 ELECTRICAL HALLWAY AXIS P3214-V 15' CAT 6 5 FREEZER AXIS P3225-LVE 15' CAT 6 6 COOLER AXIS P3225-LVE 15' CAT 6 7 BACKROOM EXIT AXIS M3006 15' CAT 6 8 PREP ROOM AXIS P3214-V 15' CAT 6 9 BREAKROOM AXIS P3214-V 15' CAT 6 10 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER AWNINGS WHEN APPLICABLE) 11 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER AWNINGS WHEN APPLICABLE) 12 BATHROOM HALLWAY AXIS M3006 15' CAT 6 13 BEER COOLER AXIS P3225-LVE 15' CAT 6 14 BEVERAGE COOLER AXIS P3225-LVE 15' CAT 6 15 SNACK/DRINK CROSS AISLE AXIS P3214-V 15' CAT 6 16 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER AWNINGS WHEN APPLICABLE) 17 EXTERIOR AXIS P3225-LVE 15' CAT 6 6.5' HEIGHT (UNDER AWNINGS WHEN APPLICABLE) 18 BEVERAGES AXIS P3214-V 15' CAT 6 19 SNACKS AXIS P3214-V 15' CAT 6 20 ATM/ QUEUE LINE AXIS M3006 15' CAT 6 21 SNACKS AXIS P3214-V 15' CAT 6 22 DOOR FRAME AXIS F1025 WITH F34 AND WREN SOLUTIONS MOUNT 15' CAT 6 PLACE AT 4'. MOUNTED IN DOOR FRAME OR WALL 23 DOOR FRAME AXIS F1025 WITH F34 AND WREN SOLUTIONS MOUNT 15' CAT 6 PLACE AT 4'. MOUNTED IN DOOR FRAME OR WALL 24 LOBBY AXIS P3225-LVE 15' CAT 6 PLACE AT 6.5' ON WALL 25 CAFÉ SEATING AXIS P3214-V 15' CAT 6 26 CAFÉ SEATING AXIS P3214-V 15' CAT 6 27 EXTERIOR AXIS P1427-LE 15' CAT 6 13'-6" HEIGHT OR ABOVE AWNINGS. 28 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER CANOPY WHEN APPLICABLE) 29 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER CANOPY WHEN APPLICABLE) 30 EXTERIOR AXIS P1427-LE 15' CAT 6 7'-6" HEIGHT (UNDER CANOPY WHEN APPLICABLE) 31 DOOR FRAME AXIS F1025 WITH F34 AND WREN SOLUTIONS MOUNT 15' CAT 6 PLACE AT 4'. MOUNTED IN DOOR FRAME OR WALL 32 DOOR FRAME AXIS F1025 WITH F34 AND WREN SOLUTIONS MOUNT 15' CAT 6 PLACE AT 4'. MOUNTED IN DOOR FRAME OR WALL 33 REGISTER AXIS F1015 WITH F34 15' CAT 6 STRAIGHT DOWN SHOT. BULLET MOUNT NOT REQUIRED. 34 REGISTER OVER VIEW AXIS M3006 15' CAT 6 35 REGISTER AXIS F1015 WITH F34 15' CAT 6 STRAIGHT DOWN SHOT. BULLET MOUNT NOT REQUIRED. 36 REGISTER AXIS F1015 WITH F34 15' CAT 6 STRAIGHT DOWN SHOT. BULLET MOUNT NOT REQUIRED. 37 REGISTER AXIS F1015 WITH F34 15' CAT 6 STRAIGHT DOWN SHOT. BULLET MOUNT NOT REQUIRED. 38 DATA CABINET AXIS P3214-V 15' CAT 6 39 SAFE AXIS P3214-V 15' CAT 6 40 OFFICE AXIS M3006 15' CAT 6 41 BACK PREP AREA AXIS P3214-V 15' CAT 6 42 EXTERIOR AXIS P1427-LE 15' CAT 6 13'-6" HEIGHT OR ABOVE AWNINGS. CAMERA FOCUS IS ON PUMPS 43 EXTERIOR AXIS P1427-LE 15' CAT 6 7'-6" HEIGHT (UNDER CANOPY WHEN APPLICABLE) 1A ABOVE CASHIER'S COUNTER PUBLIC SAFETY MONITOR 15' CAT 6 MONITOR WILL SWITCH VIEW BETWEEN PUMPS CAMS, 120V CIRCUIT REQUIRED REV. NO. SPCR NO. PROJECT LOCATION FILE NAME LAYERS DATE SCALE SHEET NO. DWG. TITLE OWNER USERNAME PROJECT NO. PLANNER KICK OFF MEETING ISSUED FOR 90% ISSUED FOR PERMIT FINAL APPROVED PLAN RECORD DRAWINGS DRAWN BY CHECKED BY GETGO #3557 4927 EAST 146TH STREET 261 KAPPA DRIVE, DATE REVISIONS BY ISSUED FOR REDLINE REVIEW GIANT EAGLE, INC. 750 HOLIDAY DRIVE, SUITE 200 PITTSBURGH, PA 15220 PHONE: 412-921-4300 FAX: 412-921-4313 PITTSBURGH, PA 15238 2016003.00 01-20-15 CARMEL, IN 46062 02-26-16 02-26-16 1 BULLETIN #2 JDF06-17-16 5 6 4 2 BULLETIN #3 JDF07-19-16 2 2 2 2 2 2