HomeMy WebLinkAboutE203 02 LOW VOLTAGE ROUGH IN - F.pdf1
2
2
3
3 3
3
3
4
TT
B
3
3
3
2
2
3
3
PB PB
PB
PB
DC
LA
PB
P
B
P
B
IC
MS
MS
PB
M
SP
V
V
V
SP
SP SP
SP SP
SP
SP
3
TV
TV
TV
T
V
TV
R-27
3
1
2
43
4
5
6
3
7
9
8
10
11
12
13
18
42
41
40
38 39
34
33 35
1A
36
37
19
20
21
22 23
24
25
26
15
14
17
16
28
27
30
31
32
J J
6 6
B CA D
E1
E2
1
2
3
XX
LOW VOLTAGE ROUGH IN - FLOOR PLAN
E203
AS NOTED
SAS
SAS
.
.
.
.
.
SCALE:
LOW VOLTAGE ROUGH IN - FLOOR PLAN
3/16" = 1'-0"1
PROVIDE (2)2" C. BELOW SLAB. STUB UP 1" ON BOTH SIDES OF
SAFE FOR ROUTING CABLING BEYOND SAFE.
E.C. SHALL PROVIDE 3/4" CONDUIT PENTRATION THROUGH
COOLER / FREEZER WALL FOR CCTV CAMERA WIRING. FOAM SEAL
AROUND CONDUIT WHERE IT ENTERS WALL OF COOLER / FREEZER.
FOAM SEAL INSIDE OF CONDUIT FOLLOWING CABLE PULL BY CCTV
VENDOR.
E.C. SHALL PROVIDE 3/4" CONDUIT STUB THROUGH EXTERIOR
WALL FOR CCTV CABLING. CAMERA AND CABLING SHALL BE
PROVIDED BY VENDOR. SEAL INSIDE AND OUTSIDE OF CONDUIT
FOLLOWING CABLE PULL BY CCTV VENDOR.
PROVIDE WIRING FROM HOOD ANSUL SYSTEM BACK TO SECURITY
CONTROL PANEL PER MANUFACTURER'S REQUIREMENTS.
COORDINATE ALARM OPERATION WITH LOCAL AHJ.
PROVIDE 6" PVC PIPE SUSPENDED FROM BOTTOM CHORD OF
TRUSS TO THE EXTENT INDICATED FOR ROUTING OF SODA LINES.
REFER TO DETAIL 2, THIS DRAWING.
PROVIDE 4" SQUARE JUNCTION BOX WITH (1) 1" AND (1) 3/4" EMT
CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING. PROVIDE 3/4"
LIQUID TIGHT FLEXIBLE METAL CONDUIT FROM JUNCTION BOX TO
CABLE CONNECTION PLATE ON ATM. PROVIDE PULL STRING IN ALL
CONDUITS. COORDINATE EXACT REQUIREMENTS WITH
MANUFACTURER REPRESENTATIVE. PROVIDE A COMPLETE AND
OPERATIONAL SYSTEM. FOR FUTURE ATM, DO NOT PROVIDE
LIQUID TIGHT FLEXIBLE METAL CONDUIT AND PROVIDE BLANK
COVER PLATE ON JUNCTION BOX.
KEY NOTES
1
2
GENERAL NOTES
CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE
SECURITY SYSTEM. COORDINATE AND ARRANGE A SITE VISIT WITH
THE LOSS PREVENTION VENDOR. CONTACT GIANT EAGLE LOSS
PREVENTION TO COORDINATE PURCHASE OF THE SECURITY
SYSTEM PACKAGE.
CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE CCTV
CAMERA SYSTEM. COORDINATE AND ARRANGE A SITE MEETING
WITH THE CCTV VENDOR. CONTACT GIANT EAGLE PROJECT
MANAGER TO COORDINATE PURCHASE OF THE CCTV SYSTEM
PACKAGE.
1.
2.
SECURITY ALARM NOTES
ALL SECURITY ALARM WIRING SHALL BE IN CONDUIT WHERE
EXPOSED IN STOCK AND EQUIPMENT ROOM. USE PLENUM RATED
CABLE EXPOSED ABOVE LAY-IN CEILINGS WHETHER SPACE IS
USED AS RETURN AIR OR NOT.
WIRE TYPE AND SIZE SHALL BE AS REQUIRED BY THE SYSTEM
MANUFACTURER.
THE WIRING SYSTEM SHALL BE CARRIED THROUGH ALL
EQUIPMENT, NO PIGTAIL TYPE (TEE) CONNECTIONS SHALL BE
ALLOWED
DUCT DETECTORS SHALL BE 24VDC
ALL FINAL TESTING AND FINAL CONNECTIONS SHALL BE BY LOSS
PREVENTION VENDOR.
COORDINATE THE QUANTITY, LOCATION & WIRING OF ALL
MECHANICAL DUCT SMOKE DETECTORS WITH MECHANICAL
ENGINEER.
ALL CONDUITS ARE TO BE RUN AS HIGH AS POSSIBLE
THROUGHOUT SALES AREA AND ANY AREAS THAT ARE OPEN TO
PUBLIC VIEW. ALL CONDUITS, WHICH ARE TO BE SUPPORTED
FROM THE STRUCTURE ABOVE, SHALL BE SUPPORTED FROM TOP
CORD OF STRUCTURAL JOIST ONLY. NO CONDUITS SHALL BE
SUPPORTED FROM BOTTOM CORD OF JOISTS OR ROOF DECK.
ADDITIONALLY, NO CONDUITS SHALL BE MOUNTED ABOVE THE
BOTTOM OF THE TOP CORD OF THE JOIST. IN NO CASE SHALL
CONDUITS BE ROUTED BETWEEN ROOF DECK AND TOP CORD OF
JOIST. NO FLEX CONDUIT OR MC CABLE TO BE USED
THROUGHOUT SALES AREA AND ANY AREAS THAT ARE OPEN TO
PUBLIC VIEW, UNLESS NOTED OTHERWISE ON PLANS.
1.
2.
3.
4.
5.
6.
7.
SECURITY WIRING LEGEND
22AWG/4C STRANDED/JACKETED, BELDEN CAT. NO. 88444
(PLENUM) OR CAT NO 8444 (NON-PLENUM IN CONDUIT ONLY
·DOOR CONTACTS
·HOLDUP ALARMS
·SIRENS
·ANNUNCIATOR KEYPADS
·ANNUNCIATED DOOR ALARM
·GLASS BREAKS
·MOTION DETECTORS
·LOCAL ALARMS
22AWG/12C STRANDED/JACKETED, BELDEN CAT. NO 82743
(PLENUM) OR CAT. NO 8747 (NON-PLENUM IN CONDUIT ONLY)
·KEY PADS
A.
B.
CCTV GENERAL NOTES
E.C. SHALL PROVIDE BRIDAL RINGS FOR CCTV CABLING FOR
CAMERAS. CABLING SHALL BE ROUTED FROM CAMERA LOCATION
BACK TO CCTV HEADEND LOCATED IN MANAGER'S OFFICE. CCTV
CABLING SHALL BE FURNISHED WITH CCTV VENDOR PACKAGE AND
INSTALLED BY CCTV VENDOR. COORDINATE BRIDAL RING
INSTALLATION LOCATIONS WITH CCTV VENDOR.
1.
3
LOW VOLTAGE GENERAL NOTES
FOR ALL LOW VOLTAGE DEVICES LOCATED ALONG THE EXTERIOR
WALL WITH GLASS ABOVE THE DEVICE, ALL WIRING SHALL BE
ROUTED FROM TRUSSES ABOVE CONCEALED IN THE MULLION.
E.C. SHALL COORDINATE WITH G.C. THAT ACCESSIBLE ROUTING
PATHS ARE AVAILABLE TO ALL DEVICE LOCATIONS FOR LOW
VOLTAGE VENDORS TO RUN THEIR CABLING.
1.
CCTV CAMERA LISTING
CAM
#DEPARTMENT CAM TYPE CABLE
TYPE REMARKS
1 EXTERIOR AXIS P1427-LE 15' CAT 6 13'-6" HEIGHT OR ABOVE AWNINGS
2 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER AWNINGS WHEN APPLICABLE)
3 EXTERIOR AXIS P1427-LE 15' CAT 6 12' HEIGHT OR ABOVE AWNINGS
4 ELECTRICAL HALLWAY AXIS P3214-V 15' CAT 6
5 FREEZER AXIS P3225-LVE 15' CAT 6
6 COOLER AXIS P3225-LVE 15' CAT 6
7 BACKROOM EXIT AXIS M3006 15' CAT 6
8 PREP ROOM AXIS P3214-V 15' CAT 6
9 BREAKROOM AXIS P3214-V 15' CAT 6
10 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER AWNINGS WHEN APPLICABLE)
11 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER AWNINGS WHEN APPLICABLE)
12 BATHROOM HALLWAY AXIS M3006 15' CAT 6
13 BEER COOLER AXIS P3225-LVE 15' CAT 6
14 BEVERAGE COOLER AXIS P3225-LVE 15' CAT 6
15 SNACK/DRINK CROSS AISLE AXIS P3214-V 15' CAT 6
16 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER AWNINGS WHEN APPLICABLE)
17 EXTERIOR AXIS P3225-LVE 15' CAT 6 6.5' HEIGHT (UNDER AWNINGS WHEN APPLICABLE)
18 BEVERAGES AXIS P3214-V 15' CAT 6
19 SNACKS AXIS P3214-V 15' CAT 6
20 ATM/ QUEUE LINE AXIS M3006 15' CAT 6
21 SNACKS AXIS P3214-V 15' CAT 6
22 DOOR FRAME
AXIS F1025 WITH F34 AND
WREN SOLUTIONS MOUNT 15' CAT 6 PLACE AT 4'. MOUNTED IN DOOR FRAME OR WALL
23 DOOR FRAME
AXIS F1025 WITH F34 AND
WREN SOLUTIONS MOUNT 15' CAT 6 PLACE AT 4'. MOUNTED IN DOOR FRAME OR WALL
24 LOBBY AXIS P3225-LVE 15' CAT 6 PLACE AT 6.5' ON WALL
25 CAFÉ SEATING AXIS P3214-V 15' CAT 6
26 CAFÉ SEATING AXIS P3214-V 15' CAT 6
27 EXTERIOR AXIS P1427-LE 15' CAT 6 13'-6" HEIGHT OR ABOVE AWNINGS.
28 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER CANOPY WHEN APPLICABLE)
29 EXTERIOR AXIS P3225-LVE 15' CAT 6 7'-6" HEIGHT (UNDER CANOPY WHEN APPLICABLE)
30 EXTERIOR AXIS P1427-LE 15' CAT 6 7'-6" HEIGHT (UNDER CANOPY WHEN APPLICABLE)
31 DOOR FRAME
AXIS F1025 WITH F34 AND
WREN SOLUTIONS MOUNT 15' CAT 6 PLACE AT 4'. MOUNTED IN DOOR FRAME OR WALL
32 DOOR FRAME
AXIS F1025 WITH F34 AND
WREN SOLUTIONS MOUNT 15' CAT 6 PLACE AT 4'. MOUNTED IN DOOR FRAME OR WALL
33 REGISTER AXIS F1015 WITH F34 15' CAT 6 STRAIGHT DOWN SHOT. BULLET MOUNT NOT REQUIRED.
34 REGISTER OVER VIEW AXIS M3006 15' CAT 6
35 REGISTER AXIS F1015 WITH F34 15' CAT 6 STRAIGHT DOWN SHOT. BULLET MOUNT NOT REQUIRED.
36 REGISTER AXIS F1015 WITH F34 15' CAT 6 STRAIGHT DOWN SHOT. BULLET MOUNT NOT REQUIRED.
37 REGISTER AXIS F1015 WITH F34 15' CAT 6 STRAIGHT DOWN SHOT. BULLET MOUNT NOT REQUIRED.
38 DATA CABINET AXIS P3214-V 15' CAT 6
39 SAFE AXIS P3214-V 15' CAT 6
40 OFFICE AXIS M3006 15' CAT 6
41 BACK PREP AREA AXIS P3214-V 15' CAT 6
42 EXTERIOR AXIS P1427-LE 15' CAT 6 13'-6" HEIGHT OR ABOVE AWNINGS. CAMERA FOCUS IS ON PUMPS
43 EXTERIOR AXIS P1427-LE 15' CAT 6 7'-6" HEIGHT (UNDER CANOPY WHEN APPLICABLE)
1A ABOVE CASHIER'S COUNTER PUBLIC SAFETY MONITOR 15' CAT 6
MONITOR WILL SWITCH VIEW BETWEEN PUMPS CAMS, 120V CIRCUIT
REQUIRED
REV.
NO.
SPCR
NO.
PROJECT
LOCATION
FILE NAME LAYERS
DATE
SCALE
SHEET NO.
DWG. TITLE
OWNER
USERNAME
PROJECT NO.
PLANNER
KICK OFF MEETING
ISSUED FOR 90%
ISSUED FOR PERMIT
FINAL APPROVED PLAN
RECORD DRAWINGS
DRAWN BY
CHECKED BY
GETGO #3557
4927 EAST 146TH STREET
261 KAPPA DRIVE,
DATE REVISIONS BY
ISSUED FOR REDLINE REVIEW
GIANT EAGLE, INC.
750 HOLIDAY DRIVE, SUITE 200
PITTSBURGH, PA 15220
PHONE: 412-921-4300
FAX: 412-921-4313
PITTSBURGH, PA 15238
2016003.00
01-20-15
CARMEL, IN 46062
02-26-16
02-26-16
1 BULLETIN #2 JDF06-17-16
5
6
4
2 BULLETIN #3 JDF07-19-16
2
2
2
2
2
2