HomeMy WebLinkAboutE704 00 ELECTRICAL DETAILS.pdfSCALE: DISPENSER FIELD WIRING NO SCALE16 PL PL PL PL N D P C N G AD G N L P 1 21 1 B 2 B 2 A 3 B 3 A 4 A 4 B A 5 5 B 6 BA 6 M E M E 1 3 4 5 E M E M E M C 2 3 C C 4 C (14) 3 1(-) 5(+) RE L A Y B A S E 2 (12) (11) 4 (14) 3 1(-) 5(+) RE L A Y B A S E 2 (12) (11) 4 1(-) 5(+) RE L A Y B A S E (14) 3 2 (12) (11) 4 (14) 3 1(-) 5(+) RE L A Y B A S E 2 (12) (11) 4 (14) 3 1(-) 5(+) RE L A Y B A S E 2 (12) (11) 4 (14) 3 1(-) 5(+) RE L A Y B A S E 2 (12) (11) 4 1(-) 5(+) RE L A Y B A S E (14) 3 2 (12) (11) 4 4 5 76 1 A A 2 A 4 3 A 3 R WIRING LEGEND #12 AWG PREINSTALLED BY FACTORY #12 AWG IN 3/4" CONDUIT INSTALLED BY ELECTRICAL CONTRACTOR 120/208 VOLT COLOR CHART NOTE BRANCH CIRCUIT WIRING DONE BY SQUARE D WILL BE COLOR CODED! A PHASE - BLACK WIRE B PHASE - RED WIRE C PHASE - BLUE WIRE ** ALL SINGLE PHASE WIRING IN BLACK** ALL WIRING ABOVE #10 AWG TO BE PHASE COLORED ON EACH END. NOTE: ·BEFORE WIRING BRANCH CIRCUITS REFER TO PANELBOARD SCHEDULES TO DETERMINE THE PHASE COLORS TO BE USED. ·ALL MAIN DISCONNECT AND BRANCH CIRCUIT PROTECTION SHALL BE PROVIDED BY OTHERS. 225A MAXIMUM @ 208 VOLTS MINIMUM. (SEE SECTION 2) DWG.-2 FOR M2 F2 1 2 3 (SEE SECTION 2) DWG.-2 FOR M4 F4 TO TERMINAL BLOCK "CPN ON DISPENSER TERMINAL STRIP DM-EX #1 DISPENSER DM-EX MODULE CHART DISP NUMBER BREAKER DESCRIPTION VOLTS AMPS PANEL CIRCUITS DM-EX #2 DM-EX #3 DM-EX #4 DM-EX #5 DM-EX #6 DM-EX #7 DM-EX #8 DISPENSER #1 SPACE FOR SWITCHED NEUTRAL DISPENSER #2 SPACE FOR SWITCHED NEUTRAL DISPENSER #3 SPACE FOR SWITCHED NEUTRAL DISPENSER #4 SPACE FOR SWITCHED NEUTRAL DISPENSER #5 SPACE FOR SWITCHED NEUTRAL DISPENSER #6 SPACE FOR SWITCHED NEUTRAL DISPENSER #7 SPACE FOR SWITCHED NEUTRAL DISPENSER #8 SPACE FOR SWITCHED NEUTRAL 120 20 FUEL-XX 120 20 FUEL-XX 120 20 FUEL-XX 120 20 FUEL-XX 120 20 FUEL-XX 120 20 FUEL-XX 120 20 FUEL-XX FUEL-XX 120 20 FUEL-XX FUEL-XX FUEL-XX FUEL-XX FUEL-XX FUEL-XX FUEL-XX FUEL-XX PUMP 4 PUMP 3 PUMP 2 PUMP 1 TO PANEL "FUEL" GROUND BAR TO PANEL "FUEL" NEUTRAL TO BREAKER "FUEL-25" (15 AMP MAX) TB2 CP ATMR5 FUSE BREAKOUT MODULE 1 1 2 4 5 6 7 8 9 1 AMP 1 AMP 1 AMP 1 AMP 1 AMP 1 AMP 1 AMP 1 AMP N 3 5 7 9 1 0 8 6 4 2 "8" R3 "7" R3 "6" R3 "5" R3 "11""10""9" CONNECT RIBBON CABLE TO DM-EX MODULE #1 (TOP RIGHT NETWORK BUS) REMOTE EMERGENCY FUEL SHUTDOWN BUTTON ON SITE (ESTOP) N/C MOMENTARY ADDITIONAL ESTOP IF USED N/C MOMENTARY REMOTE EMERGENCY FUEL SHUTDOWN BUTTON AT CASHIER CONROL CENTER (ESTOP) N/C MOMENTARY TO FUEL ESTOP RESET N/O MOMENTARY LOCATED IN THE CASHIER CONTROL CENTER PANEL (VEEDER ROOT SYSTEM) TLS RELAY OUTPUT MODULE #1 #2 #3 #4 NO C NC NO C NC NO C NC NO C NC (FOR TESTING PURPOSE'S) REMOVE JUMPERS ONCE CCO1GE2 WIRING IS TIED TO TERMINAL STRIP AS SHOWN. JUMPERS ARE FOR TESTING PRIOR TO E-STOP INSTALLATION IF REQUIRED. ELUMINATED E-STOP LTG. FIELD WIRED TO CASHIER CONTROL CENTER. P CP P1 P2 P3 P4 P5 P6 RELAY BASE 700HN121 RELAY BASE 700HK36A1 RELAY R3 CONTACTS SHOWN BELOW 1A,2A,3A,4A TERMINALS REMOTE EMERGENCY FUEL SHUTDOWN BUTTON AT CUSTOMER CONTROL CENTER (ESTOP) N/C MOMENTARY REMOVE JUMPER ONLY ONCE THE CASHIER CONTROL CENTER PUMP DISABLE SWITCH IS TIED IN. 8 7 6 5 4 3 2 1 4 3 2 1 5678 9101112 14 13 14 13 12 11 10 9 TD1 TD2 8501NR34 8501RS44P14V20 RESET LOCATED ON CABINET DOOR SEE NOTE 17 (#18 BLACK) (#18 BLACK) BLK. N/O CONTACT BLK. N/O CONTACT "BUTT-SPLICE" (P.N. #RBB) BLUE) THESE LEADS TO EXTEND WIRES TO REACH PLUT TO THE DISPENSER TERMINAL STRIP. E-STOP BLACK BLACK BLACK WHITE GREEN TO BREAKER "FUEL-37" ("A" PHASE) TO BREAKER "FUEL-39" ("B" PHASE) TO BREAKER "FUEL-41" ("C" PHASE) TO PANEL FUEL NEUTRAL BAR TO PANEL FUEL GROUND BAR (CUSTOMER SUPPLIED) BEFORE STATING THE ASSEMBLY PROCESS PLEASE READ ALL NOTES. ALL FIELD WIRING TERMINALS MUST BE WIRED WITH A MINIMUM INSULATION RATING OF 60 DEG. C IF CIRCUIT IS RATED LESS THAN 100 AMPS. OR A MINIMUM INSULATION RATING OF 75 DEG. C IF CIRCUIT IS RATED OVER 100 AMPS. WHEN CONTROLLED LOAD IS A MOTOR, CIRCUITS MUST HAVE THERMAL PROTECTION INTEGRAL TO MOTOR OR PROVIDED BY OTHERS. THIS DRAWING CONTAINS ALL THE FACTORY WIRING REQUIRED TO ASSEMBLE THESE CONTROLS. FOR A COMPLETE EXAMPLE OF ALL FIELD WIRING TO THESE CONTROLS PLEASE SEE THE DETAILS DRAWINGS IN THIS SET. THE WIRE GAUGE USED TO ASSEMBLE THESE CONTROLS VARIES THROUGHOUT. TO DETERMINE WIRE SIZE THAT SHOULD BE USED, PLEASE CHECK THE AMPERAGE OF THE CIRCUIT CONTROLLING THESE COMPONENTS. THE AMPERAGE CAN BE OBTAINED FROM THE PANELBOARD SCHEDULES DRAWING LOCATED IN THIS SET. IF THERE ARE ANY QUESTIONS ABOUT THE PLACEMENT OF ANY NON-STANDARD DEVICES ON THE DISPENSER/PUMP CONTROLS SCREEN, PLEASE CONTACT THE DRAFTING DEPARTMENT TO DETERMINE PROPER PLACEMENT. WHEN "IST-VFC" SYSTEMS ARE FACTORY INSTALLED, THE EQUIPMENT SHOULD BE MOUNTED IN THE BOTTOM OF THE LIGHTING CONTROLS SECTION. WHEN MOUNTED OUTSIDE OF THE BROWN BOX, PLACEMENT OF THESE DEVICES SHOULD BE DETERMINED BY THE CONTRACTOR. THE STANDARD DM-EX DISPENSER SCREEN MODELS ARE: DM-4D-4P. EXPANDABLE TO 6D-6P DM-6D-4P. EXPANDABLE TO 8D-6P DM-8D-4P. EXPANDABLE TO 12D-6P THE DISPENSER CONTROL WIRING SHOWN ON THIS DRAWING IS FOR THE ONE DISPENSER. ALTHOUGH THE NUMBER OF DISPENSERS USED FOR EACH JOB MAY VARY, THE WIRING SHOWN IS TYPICAL OF ALL DISPENSERS. THE PILOT LIGHTS SHOWN ON THIS DRAWING ARE TO VISUALLY VERIFY THE OPERATION OF EACH PUMP. ALL PILOT LIGHTS SHOWN SHOULD BE MOUNTED ON THE DOOR OF THE DISPENSER/PUMP CONTROLS SECTION. THE MOMENTARY SWITCHES FOR THE "FUEL SHUTDOWN" AND "FUEL RESET" SHOWN ON THIS DRAWING SHOULD BE MOUNTED ON THE DOOR OF THE DISPENSER/PUMP CONTROLS SECTION. GENERAL NOTES FOR DISPENSER/PUMP CONTROLS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. GENERAL NOTES FOR DISPENSER/PUMP CONTROLS WIRING IS TYPICAL OF ALL DISPENSERS. GROUND CONDUCTOR (#12 AWG) MUST ALSO BE RUN FROM EACH DISPENSER TO THE GROUND BAR OF THE DISPENSER/PUMP CONTROL PANEL. DISPENSER "AC" (POWER) AND "DC" (DATA) TYPICALLY RUN IN SEPARATE CONDUITS, OR PER DISPENSER MANUFACTURERS REQUIREMENTS. SEE DISPENSER INSTALLATION DIAGRAMS FOR THE TERMINATION LABELING. ALL FIELD WIRING TERMINALS MUST BE WIRED WITH A MINIMUM INSULATION RATING OF 60 1/8C. FACTORY INSTALLED "REMOTE OFF" JUMPERS ON DM-EX MODULES MUST REMAIN IN PLACE DURING NORMAL OPERATION. REMOVING THIS JUMPER AND WIRING INTO A "PAN SENSOR" SYSTEM PROVIDES INDIVIDUAL SHUTDOWN OF EACH DISPENSER. THE WIRE SIZE AND NUMBER OF CONDUCTORS REQUIRED FOR COMMUNICATION/DATA (DC) WIRING MUST BE DETERMINED BY THE SPECIFICATIONS OF THE DISPENSER MANUFACTURER. TYPICALLY 2 CONDUCTORS (NORMALLY SHIELDED CABLE) ARE REQUIRED WHEN CARD READERS IN THE DISPENSER ARE USED. 12. 13. 14. 15. 16. 17. XX ELECTRICAL DETAILS E704 AS NOTED - SAS . . . . . REV. NO. SPCR NO. PROJECT LOCATION FILE NAME LAYERS DATE SCALE SHEET NO. DWG. TITLE OWNER USERNAME PROJECT NO. PLANNER KICK OFF MEETING ISSUED FOR 90% ISSUED FOR PERMIT FINAL APPROVED PLAN RECORD DRAWINGS DRAWN BY CHECKED BY GETGO #3557 4927 EAST 146TH STREET 261 KAPPA DRIVE, DATE REVISIONS BY ISSUED FOR REDLINE REVIEW GIANT EAGLE, INC. 750 HOLIDAY DRIVE, SUITE 200 PITTSBURGH, PA 15220 PHONE: 412-921-4300 FAX: 412-921-4313 PITTSBURGH, PA 15238 2016003.00 01-20-15 CARMEL, IN 46062 02-26-16 02-26-16