HomeMy WebLinkAboutE705 00 LIGHTING CONTROLS SCHEMA.pdfNORMAL LIGHTING LOAD W/ 0-10V, 2-WIRE DIMMING FOOD PREP / RESTROOMS / COOLERS / STORAGE 3 NORMAL LIGHTING LOADS EMERGENCY LIGHTING LOADS3 3 OCCUPANCY SENSOR(S)9 7 8 8 CUSTOMER SERVICE 4 DM1 TO ADDITIONAL FIXTURES ON SAME DIMMING MODULE CONTROL GROUP NORMAL LIGHTING LOAD W/ 0-10V, 2-WIRE DIMMING NORMAL LIGHTING LOAD W/ 0-10V, 2-WIRE DIMMING3 SALES AREA 4 DM2 TO ADDITIONAL NORMAL LIGHTING FIXTURES ON SAME DIMMING MODULE CONTROL GROUP NORMAL LIGHTING LOAD W/ 0-10V, 2-WIRE DIMMING NORMAL LIGHTING LOAD W/ 0-10V, 2-WIRE DIMMING3 CAFE 4 DM3 TO ADDITIONAL FIXTURES ON SAME DIMMING MODULE CONTROL GROUP NORMAL LIGHTING LOAD W/ 0-10V, 2-WIRE DIMMING EMERGENCY LIGHTING LOAD W/ 0-10V, 2-WIRE DIMMING3 4 DM4 TO ADDITIONAL EMERGENCY LIGHTING FIXTURES ON SAME DIMMING MODULE CONTROL GROUP EMERGENCY LIGHTING LOAD W/ 0-10V, 2-WIRE DIMMING 6 3 OFFICE / BREAKROOM 10 NORMAL LIGHTING LOAD W/ 0-10V, 2-WIRE DIMMING 11 6 3 ELECTRICAL AREA NORMAL LIGHTING LOADS NORMAL LIGHTING LOAD W/ 0-10V, 2-WIRE DIMMING TO ADDITIONAL FIXTURES (IF APPLICABLE) 3 BUILDING EXTERIOR NORMAL LIGHTING LOADS 3 EMERGENCY LIGHTING LOADS DAYLIGHT SENSOR (PHOTOCELL)5 ELECTRICAL ROOM NORMAL LIGHTING CPC DIMMING MODULE ENCLOSURE ('DM1', 'DM2' & 'DM3') EMERGENCY LIGHTING CPC DIMMING MODULE ENCLOSURE ('DM4') BMS CPC I/O ENCLOSURE 'BM1' 2 120VAC INVERTER POWER. SEE ELECTRICAL DWGS 1 4 TYP 4 TYP 1 5 CAFE PHOTOCELL PHOTOCELL ON ROOF 5 1 KEY NOTESX POWER FOR CPC LIGHTING CONTROL SYSTEM EQUIPMENT TO BE DERIVED FROM INVERTER OUTPUT. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. DIMMING MODULE CONTROL CABLING. EACH DIMMING MODULE TO HAVE DEDICATED CONTROL CABLING FROM BMS CPC I/O ENCLOSURE 'BM1' ANALOG OUTPUT BY E.C. PER MANUFACTURER'S REQUIREMENTS. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. POWER FEEDS TO FIXTURES. WIRE AND CONDUIT BY E.C. (DEDICATED NEUTRALS REQUIRED). POWER TO BE ROUTED THROUGH CONTROL CONTACTORS. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 0-10V DIMMING SIGNAL TO FIXTURES (#18-2 SHIELDED CABLE) FROM INDICATED CPC DIMMING MODULE. WIRE AND CONDUIT BY E.C. WIRING CANNOT SHARE RACEWAY WITH LINE VOLTAGE WIRING. CABLING TO PHOTOCELL BY E.C. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. LINE-VOLTAGE, WALL MOUNTED OCCUPANCY SENSOR. REFER TO ELECTRICAL DRAWINGS FOR EXACT LOCATIONS AND SPECIFICATION. LOW-VOLTAGE, CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. REFER TO ELECTRICAL DRAWINGS FOR EXACT LOCATIONS AND SPECIFICATION. POWERPACK LIGHTING CONTROL VIA LOCAL CEILING MOUNTED OCCUPANCY SENSOR. REFER TO ELECTRICAL DRAWINGS FOR EXACT LOCATIONS AND SPECIFICATION. LOW VOLTAGE WIRING BETWEEN CEILING MOUNTED OCCUPANCY SENSOR AND POWERPACK PER MANUFACTURER'S REQUIREMENTS. LOW-VOLTAGE, WALL DIMMER SWITCH. REFER TO ELECTRICAL DRAWINGS FOR EXACT LOCATIONS AND SPECIFICATION. 0-10V DIMMING SIGNAL TO FIXTURES (#18-2 SHIELDED CABLE) FROM LOW VOLTAGE WALL DIMMER SWITCH. WIRE AND CONDUIT BY E.C. WIRING CANNOT SHARE RACEWAY WITH LINE VOLTAGE WIRING. 1 2 3 4 5 6 7 8 9 10 11 GENERAL NOTES A.SINGLE LINE DIAGRAM IS FOR SCHEMATIC DESIGN INTENT PURPOSES ONLY. ALL LAYOUTS, SIZING, CODE REQUIREMENTS PER E.E. ALL WIRE/INTEGRATION PER E.C. IN CONJUNCTION WITH MANUFACTURER. THIS IS IN NO WAY A SHOP DRAWING AND SHOULD NOT BE USED AS AN INSTALLATION GUIDE. B.E.C. TO ALLOW FOR PROGRAMMING AND COMMISSIONING, AS WELL AS TRAINING SESSIONS FOR THE OWNER. C.CONTROL LAYOUT IS SCHEMATIC ONLY. E.C. IS RESPONSIBLE FOR COORDINATING THE LAYOUT OF THE ACTUAL LIGHTING CONTROL EQUIPMENT WITH THE OTHER EQUIPMENT LOCATED WITHIN THE SPACE ACCORDING TO CODE. THE E.C. SHALL SUBMIT A COORDINATED ELEVATION DURING THE SHOP DRAWING PHASE FOR REVIEW. D.CONTROLS SHOWN ARE FOR BUILDING-MOUNTED EXTERIOR LIGHTING AND INTERIOR LIGHTING ONLY, AND DO NOT INCLUDE SITE AND PUMP-CANOPY LIGHTS. XX LIGHTING CONTROLS SCHEMATICS E705 AS NOTED SAS JER SCALE: 2 NTS4 UNDER SIDE OF ROOF DECK UNISTRUT MOUNTED TO TOP CHORD OF ROOF TRUSS JUNCTION BOX MOUNTED TO BOTTOM UNISTRUT CONDUIT STEM BOTTOM CHORD OF TRUSS TYPE DL1/DL2 STEM MOUNTED FROM UNISTRUT NOTE: 1.E.C. IS RESPONSIBLE FOR PROVIDING ALL MOUNTING HARDWARE. CONDUIT FEEDS, CABLE CONNECTORS, AND OTHER ACCESSORIES AS NEEDED. COORDINATE INSTALLATION WITH THE G.C. REFERENCE ARCHITECTURAL DETAILS FOR ADDITIONAL INFORMATION. 2.FIXTURES SHALL BE CENTERED BETWEEN TRUSSES. UNISTRUT MOUNTED TO TOP OF BOTTOM CHORD OF TRUSS LS FIXTURE PENDANT MOUNTED 6" BELOW BOTTOM CHORD OF TRUSS NOTE: 1.E.C. IS RESPONSIBLE FOR PROVIDING ALL MOUNTING HARDWARE, CONDUIT FEEDS CABLE CONNECTORS, AND OTHER ACCESSORIES AS NEEDED. COORDINATE INSTALLATION WITH THE G.C. REFERENCE ARCHITECTURAL DETAILS FOR ADDITIONAL INFORMATION. SCALE: TYPE LS SECTION DETAIL NTS1 REV. NO. SPCR NO. PROJECT LOCATION FILE NAME LAYERS DATE SCALE SHEET NO. DWG. TITLE OWNER USERNAME PROJECT NO. PLANNER KICK OFF MEETING ISSUED FOR 90% ISSUED FOR PERMIT FINAL APPROVED PLAN RECORD DRAWINGS DRAWN BY CHECKED BY GETGO #3557 4927 EAST 146TH STREET 261 KAPPA DRIVE, DATE REVISIONS BY ISSUED FOR REDLINE REVIEW GIANT EAGLE, INC. 750 HOLIDAY DRIVE, SUITE 200 PITTSBURGH, PA 15220 PHONE: 412-921-4300 FAX: 412-921-4313 PITTSBURGH, PA 15238 2016003.00 01-20-15 CARMEL, IN 46062 02-26-16 02-26-16