HomeMy WebLinkAboutLV001 00 LOW VOLTAGE SCHEDULE.pdfXX
LOW VOLTAGE SCHEDULE
LV001
AS NOTED
SAS
SAS
.
.
.
.
.
CABLE AND CONDUIT FOR LOW VOLTAGE NOTES
ALL CABLES AND WIRING FOR DEVICES INDICATED ON TIS SHEET ARE TO
BE ROUTED, GROUPED, & SUPPORTED PER THE APPLICABLE CRITERIA
BELOW AND THE CONDUIT AND BRIDLE RING GENERAL NOTES WHICH
FOLLOW:
A. IN AREAS WITHOUT SUSPENDED CEILING, EXPOSED
TO STRUCTURE:
- CABLES SHALL BE ROUTED IN CONDUIT VERTICALLY FROM
THE ASSOCIATED DEVICE UP TO THE BOTTOM SIDE OF THE
BAR JOISTS. CONDUITS SHALL BE PROVIDED FOR VERTICAL
ROUTING WHETHER EXPOSED OR CONCEALED IN PARTITION
WALLS. REFER TO GENERAL CONDUIT NOTES BELOW.
- AT THE BAR JOIST HEIGHT, CABLES SHALL BE ROUTED
HORIZONTALLY ALONG THE BOTTOM CHORDS OF THE BAR
JOISTS THROUGH BRIDLE RINGS. REFER TO GENERAL
BRIDLE RING NOTES BELOW.
B.IN AREAS WITH SUSPENDED CEILING, WHERE SPACE ABOVE
CEILING IS NOT VISIBLE FROM SALES FLOOR:
- CABLES SHALL BE ROUTED IN CONDUIT VERTICALLY FROM
THE ASSOCIATED DEVICE UP TO 12" ABOVE THE
SUSPENDED CEILING. REFER TO GENERAL CONDUIT NOTES
BELOW.
- AT THE BAR JOIST HEIGHT, CABLES SHALL BE ROUTED
HORIZONTALLY ALONG THE BOTTOM CHORDS OF THE BAR
JOISTS THROUGH BRIDLE RINGS. REFER TO GENERAL
BRIDLE RING NOTES BELOW.
C.IN AREAS WITH SUSPENDED CEILING, WHERE SPACE ABOVE
CEILING IS VISIBLE FROM SALES FLOOR:
- CABLES SHALL BE ROUTED VERTICALLY FROM THE
ASSOCIATED DEVICE UP TO THE BOTTOM SIDE OF THE BAR
JOISTS. WHERE CONDUITS RISE FROM CEILING HEIGHT TO
BOTTOM OF BAR JOISTS, CONDUITS SHALL BE GROUPED
WITH OTHER CONDUITS WHICH FEED SAME AREA.
HORIZONTAL RUNS DIRECTLY ABOVE SUSPENDED CEILING
FROM DEVICE LOCATION TO GROUPED CONDUIT RISE
LOCATION SHALL ALL BE IN CONDUIT. REFER TO GENERAL
CONDUIT NOTES BELOW.
- AT THE BAR JOIST HEIGHT, CABLES SHALL BE ROUTED
HORIZONTALLY ALONG THE BOTTOM CHORDS OF THE BAR
JOISTS THROUGH BRIDLE RINGS. REFER TO GENERAL
BRIDLE RING NOTES BELOW.
D. ON TOP OF REFRIGERATED CASES, COOLERS/FREEZERS,
EQUIPMENT OR ANY AREAS SUBJECT TO DAMAGE::
-CABLES SHALL BE ROUTED IN CONDUIT REFER TO
GENERAL CONDUIT NOTES BELOW.
E.UNDERGROUND OR IN REFRIGERATION PITS AND
TRENCHES:
- CABLES SHALL BE ROUTED IN CONDUIT. REFER TO
GENERAL CONDUIT NOTES BELOW
GENERAL CONDUIT NOTES:
1. IF CONDUIT SIZES ARE NOT NOTED ON DRAWINGS, MINIMUM
SIZE SHALL BE 3/4" OR BASED ON 40% MAXIMUM FILL.
2. CONDUIT SHALL BE DEDICATED PER SYSTEM. DO NOT
SHARE CONDUITS FOR DIFFERENT LOW VOLTAGE SYSTEM
CABLES.
3.PROVIDE NYLON BUSHINGS AT END OF ALL CONDUITS AND
NYLON PULLSTRINGS IN ALL CONDUITS.
4.REFER TO SPECIFICATIONS FOR CONDUIT TYPES AND USES.
GENERAL BRIDLE RING NOTES:
1. RINGS SHALL BE SHARED FOR ROUTING MULTIPLE SYSTEM
CABLES.
2. RINGS SHALL BE MOUNTED TO BOTTOM CHORD OF BAR
JOISTS IN AN ORIENTATION WHICH PLACES THE OPENING OF
THE RING ABOVE THE BOTTOM CHORD TO MINIMIZE
VISIBILITY FROM THE SALES FLOOR.
3.RING FINISH MUST BE APPROVED BY ARCHITECT IF IT IS TO
BE OTHER THAN UNFINISHED STEEL.
GENERAL CABLE NOTES:
1.ALL CABLES USED FOR DATA, CCTV, SOUND SYSTEM OR
EMS SYSTEM WHERE INSTALLED IN AREAS WITHOUT
CEILING AND WITH EXPOSED STRUCTURE MUST BE BROWN
OR BLACK IN COLOR. NO EXPOSED CABLES IN THESE AREAS
SHALL BE WHITE.
2.CONFIRM CABLE COLORS WITH ARCHITECT PRIOR TO
ORDERING.
CABLE AND CONDUIT FOR LOW VOLTAGE NOTES CABLE AND CONDUIT FOR LOW VOLTAGE NOTES
STANDARD FUEL STATION TELECOMMUNICATIONS WIRE SCHEDULE
TERMINATION PANEL HARDWARE USE
TELEPHONE COMPUTER REGISTERS TELEPHONE TYPE OF CABLE
DEPT./AREA NAME PRINT
ID#
JACK
TYPE
PORT ID
#EQUIPMENT SERVED CABLE
FROM IDF VOICE DATA CATA LINA CASH REG DEDICATED
LINE
TWO LINE
ANALOG
PLENUM
COAX
PLENUM
VOICE
CAT5E
PLENUM
DATA CAT5E
SPARE/
MISC.
NOTES
CCTV RACK 23 6 PORT
1
2
3
4
5 CCTV A 1 1
6 CCTV A 1 1
DATA RACK
24 6 PORT
1
2
3 CC CONTROLLER A 1 1
4 CC CONTROLLER UPS A 1 1
5 DD CONTROLLER A 1 1
6 DD CONTROLLER UPS A 1 1
25 6 PORT
1
2
3
4
5 PUMP SERVER A 1 1
6 PUMP SERVER A 1 1
ELECTRICAL
EQUIPMENT ROOM
26 6 PORT
1
2
3
4
5 PIM/CIM UPS A 1 1
6 PIM/CIM UPS A 1 1
27 6 PORT
1
2
3
4
5
6 MTI A 1 1
28 2 PORT
1 STORE ALARM A 1 1 1
2 SPARE A 1 1 1
D TV 29 6 PORT
1
2
3
4
5
6 DIRECTV A-B 1 1
DEMARC 30 6 PORT
1 PRIMARY A-B 1 1
2
3
4
5
6 BACKUP A-B 1 1
VEEDER ROOT 31 6 PORT
1
2
3
4
5
6 VEEDER ROOT B 1 1
REDBOX 32 1 PORT 1 RED BOX A 1 1
DISPLAY TV 33 1 PORT 1 TV A 1 1 1
DISPLAY TV 34 1 PORT 1 TV A 1 1 1
DISPLAY TV 35 1 PORT 1 TV A 1 1 1
DISPLAY TV 36 1 PORT 1 TV A 1 1 1
DISPLAY TV 37 1 PORT 1 TV A 1 1 1
BREAK ROOM 38 6 PORT
1 PHONE A 1 1 1
2
3
4
5 SPARE A 1 1
6 PC A 1 1
----25 PAIR A 1 FEED FROM DEMARC
TOTALS ---18 49 0 4 4 6 16 12 52 0 TOTAL DOES NOT INCLUDE 25 PAIR
STANDARD FUEL STATION TELECOMMUNICATIONS WIRE SCHEDULE
TERMINATION PANEL HARDWARE USE
TELEPHONE COMPUTER REGISTERS TELEPHONE TYPE OF CABLE
DEPT./AREA NAME PRINT
ID#
JACK
TYPE
PORT ID
#
EQUIPMENT SERVED CABLE FROM
IDF
VOICE DATA CATA LINA CASH REG DEDICATED
LINE
TWO LINE
ANALOG
PLENUM
COAX
PLENUM
VOICE
CAT5E
PLENUM
DATA CAT5E
SPARE/
MISC.
NOTES
LOTTERY 1 6 PORT 1
2
3
4
5
6 OHIO LOTTERY A 1 1
ATM 2 6 PORT 1
2
3
4
5 ATM A 1 1
6 ATM A 1 1
CUSTOMER SERVICE 3 6 PORT 1 PHONE A 1 1 1
2
3
4 SPARE A 1 1
5 LOTTERY A 1 1
6 REGISTER A 1 1
4 6 PORT 1 PHONE A 1 1 1
2
3
4 SPARE A 1 1
5 LOTTERY A 1 1
6 REGISTER A 1 1
5 1 PORT 1 COIN SAFE A 1 1 1
6 6 PORT 1 PHONE A 1 1 1
2
3
4 SPARE A 1 1
5 LOTTERY A 1 1
6 REGISTER A 1 1
7 6 PORT 1 PHONE A 1 1 1
2
3
4 SPARE A 1 1
5 LOTTERY A 1 1
6 REGISTER A 1 1
DELI 8 1 PORT 8 DELI ORDER KIOSK A 8 4 4
12 1 PORT 1 ORDER MONITOR A 1 1 1
13 1 PORT 1 ORDER MONITOR A 1 1 1
14 1 PORT 1 ORDER MONITOR A 1 1 1
15 1 PORT 1 ORDER MONITOR A 1 1 1
39 1 PORT 1 ORDER MONITOR A 1 1 1
16 6 PORT 1
2
3
4
5 PRINTER A 1 1
6 PRINTER A 1 1
17 6 PORT 1
2
3
4
5
6 PRINTER A 1 1
ESPRESSO PRINTER 18 6 PORT 1
2
3
4
5
6 PRINTER A 1 1
AP 19 1 PORT 1 ACCESS POINT A 1 1
TIMECLOCK 20 WALL 1 TIMECLOCK A 1 1
MANAGER'S OFFICE 21 6 PORT 1 PHONE A 1 1 1
2
3
4
5 SPARE A 1 1
6 PC A 1 1
22 6 PORT 1 FAX A 1 1 1
2
3
4
5
6 COPIER/PRINTER A 1 1
REV.
NO.
SPCR
NO.
PROJECT
LOCATION
FILE NAME LAYERS
DATE
SCALE
SHEET NO.
DWG. TITLE
OWNER
USERNAME
PROJECT NO.
PLANNER
KICK OFF MEETING
ISSUED FOR 90%
ISSUED FOR PERMIT
FINAL APPROVED PLAN
RECORD DRAWINGS
DRAWN BY
CHECKED BY
GETGO #3557
4927 EAST 146TH STREET
261 KAPPA DRIVE,
DATE REVISIONS BY
ISSUED FOR REDLINE REVIEW
GIANT EAGLE, INC.
750 HOLIDAY DRIVE, SUITE 200
PITTSBURGH, PA 15220
PHONE: 412-921-4300
FAX: 412-921-4313
PITTSBURGH, PA 15238
2016003.00
01-20-15
CARMEL, IN 46062
02-26-16
02-26-16