HomeMy WebLinkAboutM501 00 MECHANICAL KITCHEN HOOD.pdfGREASE DRAIN WITH REMOVABLE CUP 4" EXHAUST RISER HANGING ANGLE SCREW IN COMPACT FLUORESCENT BULB, INCANDESCENT LIGHT FIXTURE-HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE FIELD WRAPPER 20.00" HIGH (SEE HOOD OPTIONS TABLE) EQUIPMENT BY OTHERS 48.0" MAX 24" NOM. 48" SECTION VIEW - MODEL 4824ND-2 16" SS BAFFLE WITH HANDLES AND HOOK TEMP SENSOR 3" BACK STANDOFF - WEATHERPROOF DISCONNECT - GREASE CLASSIFICATION TESTING - HIGH HEAT OPERATION 300°F (149°C) - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH 21 17 1/2 13 1/4 30 1/4 27 1/4 2 21 1/2 GREASE DRAIN FEATURES: - RESTAURANT MODEL - ROOF MOUNTED FANS - UL705 AND UL762 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) 3" FLANGE 17 1/2 17 1/2 ROOF OPENING DIMENSIONS 20 GAUGE CONSTRUCTION STEEL 24" 19 1/2" 19 1/2" VENTED CURB FAN #1 NCA10FA - EXHAUST FAN (EF/1) OPTIONS GREASE BOX NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. NOTES - FIELD PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE. - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE-PIPED CHARBROILER DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS 4' 0.00"Nom./4' 0.00"OD 48" 12" Utility Cabinet 3" 24"24" 8 1/2" 9" 8" PLAN VIEW - Hood #1 (EH-1) 4' 0.00" LONG 4824ND-2 U.L. Listed Screw In Compact Fluorescent Bulb Fr y e r - M w / D r i p B o a r d Hi g h P r o x i m i t y 16 . 0 0 " L x 2 1 . 0 0 " D Fr y e r - M w / D r i p B o a r d Hi g h P r o x i m i t y 16 . 0 0 " L x 2 1 . 0 0 " D 28 30 1W 1N 3N 37 1/2" 3N 16"16"16" EXHAUST RISER TEMP SENSOR ANSUL FIRE SUPPRESSION SYSTEM ELECTRICAL PREWIRE PACKAGE (w/ Equipment Contactors) DETAIL - ANSUL FIRE SUPPRESSION SYSTEM FAN & LIGHT CONTROL PANEL FANSLIGHTS 34 10 5 11 7 1B 3 ROOM TEMP SENSOR 5'-1.00" Overall Length 1" LAYER OF INSULATION FACTORY INSTALLED IN 1.00" END STANDOFF MEETS 0" REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. 1"Fire System Information 1 Ansul R102 3.0 8 Fire Cabinet Left Right FIRE SYSTEM NO. TYPE SIZE FLOW POINTS INSTALLATION SYSTEM LOCATION ON HOOD HOOD INFORMATION 1 EH-1 4824 ND-2 4' 0.00" 450 Deg.800 9"8"800 -0.307"304 SS Where Exposed ALONE ALONE HOOD NO.TAG MODEL LENGTH MAX. COOKING TEMP. EXHAUST PLENUM TOTAL EXH. CFM RISER(S) WIDTH LENG.DIA.CFM S.P. HOOD CONSTRUCTION HOOD CONFIG. END TO END ROW HOOD INFORMATION 1 EH-1 SS Baffle with Handles 2 16"16" 2 Screw In Compact NO Left Ansul R102 3.0 SC-110110MA 1 Light 1 Fan YES 358 LBS HOOD NO.TAG FILTER(S) TYPE QTY.HEIGHT LENGTH LIGHT(S) QTY.TYPE WIRE GUARD UTILITY CABINET(S) LOCATION FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WGHT ELECTRICAL PACKAGES 1 ES-1 SC-110110MA Utility Cabinet Left Utility Cabinet Left Hood # 1 1 Light 1 Fan Smart Controls Thermostatic Control w/ Relay On/Off with Supply Exhaust 1 0.333 115 7.0 NO.TAG PACKAGE #LOCATION SWITCHES LOCATION QUANTITY OPTION FANS CONTROLLED TYPE Ø H.P.VOLT FLA EXHAUST FAN INFORMATION 1 EF/1 NCA10FA 800 0.700 1130 0.333 1 115 7.0 108 5.9 FAN UNIT NO. TAG FAN UNIT MODEL #CFM ESP.RPM H.P.Ø VOLT FLA WEIGHT (LBS.)SONES FAN OPTIONS 1 EF/1 1 - Grease Box FAN UNIT NO. TAG OPTION (Qty. - Descr.) CURB ASSEMBLIES 1 # 1 34 LBS Curb 19.500"W x 19.500"L x 24.000"H Vented Hinged NO.ON FAN WEIGHT ITEM SIZE HOOD OPTIONS 1 EH-1 FIELD WRAPPER 20.00" High Front, Left, Right RIGHT END STANDOFF (FINISHED) 1" Wide 48" Long Insulated HOOD NO.TAG OPTION DESCRIPTION OF OPERATION: Get Go - #3557 SC-110110MA INSTALL ECP #1-1 120V 1 Phase w/ 1 Exhaust Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. BREAKER PANEL TO CONTROL PANEL Responsibility: Electrician BREAKER PANEL CONTROL PANEL BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED BREAKER 1PH CONTROL POWER. DO NOT WIRE TO SHUNT TRIP BREAKER. Hot Neutral H1 N1120 V 15 A Ground GND 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 BREAKER 1PH Hot Neutral L1 FN1 GNDGround EF/1 115 V 15 AMP BREAKER 3PH WIRE directly to Equipment Contactor PN: VOLT:MAX MAX AMP: LINE LINE 208 V LINE L1 L2 L3 Ground GND FRYER#1 AC_1 100-C60D10 208 V70 AMP 60 AMP BREAKER 3PH WIRE directly to Equipment Contactor PN: VOLT:MAX MAX AMP: LINE LINE 208 V LINE L1 L2 L3 Ground GND FRYER#2 AC_2 100-C60D10 208 V70 AMP 60 AMP BREAKER 1PH BREAKER 1PH WIRE directly to Equipment Contactor PN: VOLT1: VOLT2: MAX MAX MAX AMP1: MAX AMP2: Hot Neutral L1 L2115 V 115 V Neutral Hot L4 L3 DUMP AC_3 FREEZER Ground GND Ground GND 100-C23D400 115 V 115 V 25 AMP 25 AMP 23 AMP 23 AMP CONTROL PANEL TO FANS Responsibility: Electrician CONTROL PANEL FANS Load Wiring WIRE DIRECT TO STARTER WIRE TO DISCONNECT T1 T2 EF/1 LEG 1 / HOT LEG 2 / NEUTRAL GND GROUND C-1 01FAN: 7.0 0.333 115 V CONTROL PANEL TO ACCESSORY ITEMS Responsibility: Electrician CONTROL PANEL COMPONENT WIRE C TO COMMON. WIRE AR1 TO NORMALLY CLOSED. C1 TO AR1 SHOULD HAVE HOOD PANEL FIRE SYSTEM TO MICROSWITCH CONTINUITY WHEN ARMED. IF MORE THAN WIRE IN SERIES ONE FIRE SYSTEM AS SHOWN HERE C1 AR1 MICROSWITCH 1 1:C 4:NO 2:NC MS-1 1:C 4:NO 2:NC 1:C 4:NO 2:NC MS-2 ALL SWITCHES FACTORY WIRED CAT-5 CONNECTION HOOD PANEL SWITCHES TO J4 HOOD PANEL HOOD LIGHTS TO 1400 W MAX WIRE TO J-BOX ON TOP OF HOOD B1 W1 GND BLACK WHITE GREEN HOOD LIGHTS 1 WIRE TO CONTROL BOARD. SENSOR MOUNTED IN ROOM AWAY FROM HEAT SOURCES. SEE MANUAL HOOD PANEL KITCHEN TEMP TO SENSOR T1A T1B ROOM TEMP FACTORY WIRED TEMPERATURE SENSOR. MOUNTED IN EXHAUST DUCT HOOD PANEL DUCT SENSOR TO T2A T2B HOOD 1 RISER 1 EXTERNAL SPARE CONTACT ON/OFF WITH FIRE WIRE DIRECT TO CONTACTOR HOOD PANEL ON/OFF WITH CIRCUIT FIRE T1 T2 line line FRYER#1 GroundGND T3 line EQT1 EXTERNAL SPARE CONTACT ON/OFF WITH FIRE WIRE DIRECT TO CONTACTOR HOOD PANEL ON/OFF WITH CIRCUIT FIRE T1 T2 line line FRYER#2 GroundGND T3 line EQT2 EXTERNAL EXTERNAL SPARE CONTACT ON/OFF WITH FIRE. WIRE DIRECT TO CONTACTOR HOOD PANEL ON/OFF WITH CIRCUIT FIRE T1 T2 Hot Neutral FREEZERGroundGND T3 T4 Hot Neutral DUMPGroundGNDEQT3 THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE SPECIFICATIONS HOOD PANEL EXTERNAL SIGNAL FOR SHUNT TRIP ST TERMINAL IS ENERGIZED IN FIRE CONDITION. ST N1 NEUTRAL FROM SHUNT COIL HOT TO SHUNT COIL SHUNT COIL SPARE CONTACTS USED WHEN FIRE HOOD PANEL SYSTEM DRY SPARE FIRE CONTACT SYSTEM DISCHARGES TO DISABLE EQUIPMENT OR PROVIDE SIGNALS. (NOT FOR BUILDING FIRE ALARM) C2 AR2 COMMON NORMALLY OPEN SPARE CONTACTS WILL MAKE HOOD PANEL ON/OFF WITH DRY CONTACT SUPPLY FAN COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. GROUP 1 SFC1 SFO1 COMMON NORMALLY OPEN SFC2 SFO2 COMMON NORMALLY OPEN MECHANICAL KITCHEN HOOD DETAILS M501 AS NOTED JPO PIB XXX FI L T R A T I O N E F F I C I E N C Y ( % ) 0 0.1 10 20 30 40 1 PARTICLE DIAMETER (um) 10 FILTER COLLECTION EFFICIENCY 90 50 60 80 70 100 2" Captrate Grease-Stop Solo FilterRR Made From 430 Stainless Steel ETL Listed Grease Extracting Filters CaptiveAire Captrate Solo Filter STANDARD 710 SLI DTE R R ACCORDANCE No. 96 BUILT NFPA WITH IN REV. NO. SPCR NO. PROJECT LOCATION FILE NAME LAYERS DATE SCALE SHEET NO. DWG. TITLE OWNER USERNAME PROJECT NO. PLANNER KICK OFF MEETING ISSUED FOR 90% ISSUED FOR PERMIT FINAL APPROVED PLAN RECORD DRAWINGS DRAWN BY CHECKED BY GETGO #3557 4927 EAST 146TH STREET 261 KAPPA DRIVE, DATE REVISIONS BY ISSUED FOR REDLINE REVIEW GIANT EAGLE, INC. 750 HOLIDAY DRIVE, SUITE 200 PITTSBURGH, PA 15220 PHONE: 412-921-4300 FAX: 412-921-4313 PITTSBURGH, PA 15238 2016003.00 01-20-15 CARMEL, IN 46062 02-26-16 02-26-16