HomeMy WebLinkAboutM502 00 MECHANICAL DETAILS.pdfMECHANICAL DETAILS M502 AS NOTED JPO PIB SCALE: DUCT HANGER ATTACHMENT NOT TO SCALE1 SCALE: DUCT TAKE OFF FROM SQUARE DUCT NOT TO SCALE2 SCALE: FLEXIBLE DUCT DETAIL NOT TO SCALE3 SCALE: KITCHEN HOOD EXHAUST FAN DETAIL NOT TO SCALE4 SCALE: FIRE SUPPRESSION PIPING DETAIL NOT TO SCALE6 SCALE: SECTION B ELEVATION NTS8 SCALE: HOOD SYSTEM DETAIL NOT TO SCALE5 SCALE: ROOF CURB LEVELING DETAIL NOT TO SCALE 9 JOISTS - REFER TO STRUCTURAL DRAWINGS JOISTS - REFER TO STRUCTURAL DRAWINGS SECURE DUCT TO UNISTRUT UNISTRUT SUPPORT SECURED TO TOP CHORD OF JOIST - SIZE FOR LOAD ROOF SECURE DUCT TO UNISTRUT UNISTRUT SUPPORT SECURED TO TOP CHORD OF JOIST - SIZE FOR LOAD DIRECTION OF AIR FLOW (RETURN) DIRECTION OF AIR FLOW (SUPPLY) MAIN DUCT CLOSE OPENING AT CORNERS 1/4 OF DUCT WIDTH MINIMUM OF 4" BRANCH DUCT DUCT WIDTH SURVERYOR'S TAPE (PROVIDE WHEN DAMPER IS LOCATED ABOVE SUSPENDED CEILING) VOLUME DAMPER 45 DEGREE ENTRY ISOMETRIC VIEW PLAN VIEW ALL INSULATED SUPPLY DUCT AND RETURN DUCTWORK SHALL BE FURNISHED AND INSTALLED WITH STAND-OFF MOUNTING BRACKETS FOR VOLUME/BALANCEING DAMPER OPERATORS. ALLOW CLEARANCE BETWEEN DUCT AND OPERATOR OF NOT LESS THAN INSULATION THICKNESS. OR OR OR SURVERYOR'S TAPE (PROVIDE WHEN DAMPER IS LOCATED ABOVE SUSPENDED CEILING) OPPOSED BLADE BALANCING DAMPER STAND-OFF MOUNTING BRACKET BRANCH DUCT MAIN DUCT 45 DEGREE TAKE-OFF FROM SIDE OF SUPPLY MAIN WITH GALVANIZED DUCT AND VOLUME DAMPER PROVIDE RADIUS ELBOWS WHERE SPACE ALLOWS. WHERE SPACE DOESEN'T ALLOW A FULL RADIUS PROVIDE MITERED ELBOWS WITH SINGLE THICKNESS TURNING VANES. 5'-0" MAXIMUM LENGTH OF FLEXIBLE DUCT. RUN STRAIGHT, NOT BENDS OR KINDS AND PULL TIGHT. SUSPENDED CEILING DIFFUSER SHEET METAL SQUARE TO ROUND TRANSITION METAL BAND CLAMP INSULATED FLEXIBLE DUCT METAL BAND CLAMP DUCT SHALL BE INSTALLED WITHOUT FORMING DIPS OR TRAPS THAT MIGHT COLLECT RESIDUES. SEE FLOOR PLAN FOR DUCT SIZE AND CONTINUATION ROOF JOIST (TYPICAL) FROM KITCHEN HOOD INSULATE GREASE DUCT WITH ZERO-CLEARANCE TO COMBUSTIBLE INSULATION AS INDICATED IN SPECIFICATIONS. GREASE GUARDROOF CURB GREASE COLLECTOR PAN GREASE DRAIN SPOUT FLANGE OVER ROOF CURB. SEAL CORNERS TO PREVENT LEAKAGE INSIDE BUILDING. HINGED SUB BASE KITCHEN HOOD EXHAUST FAN. ORIENT HINGED SUB-BASE SO THAT FLEXIBLE CONDUIT TO FAN IS ON SAME SIDE AS HINGE. 10'-0" MINIMUM FROM ROOF EDGE OR PARAPET EXHAUST FAN SUPPORT HOOD WITH 4X4X1/4 STEEL ANGLE ATTACHED TO TOP CHORD OF ROOF JOIST. ALL STEEL ANGLES SHALL SPAN A MINIMUM OF 3 JOISTS. 18" MINIMUM CURB HEIGHT. 40" MIN. HEIGHT PER N.F.P.A. DUCT SIZES AS REQUIRED. CLEAN OUT ACCESS DOOR AT EACH CHANGE IN DIRECTION OF EXHAUST DUCT AS REQUIRED BY NFPA 96. INSTALL HORIZONTAL SECTION OF DUCT SO ACCESS DOORS ARE WITHIN REACH OF SERVICE PERSONNEL VIA STEP LADDER THROUGH CEILING. CEILING STAINLESS STEEL SKIRT BY MECH. SUBCONTRACTOR SIZE AS REQUIRED VAPOR PROOF LIGHT TOP OF HOOD FILTER 2' - 0 " REFER TO M501 FOR MOUNTING HEIGHT. FINISHED FLOOR GREASE TROUGH REFER TO M501 FOR HOOD DIMENSIONS. 20 GAUGE STAINLESS STEEL BACKSPLASH BY M.C. BACKSPLASH SHALL BE CONSTRUCTED IN A MANNER THAT DOESEN'T CREATE SEAMS. EXTEND PANEL TO TOP OF HOOD AND EXTEND 18" BEYOND EACH SIDE OF HOOD. REFER TO M101 DRAWING. PROVIDE ACCESS DOOR IN HOOD FOR ACCESS TO FIRE DAMPER WHEN DAMPER IS NOT EASILY ACCESSIBLE FROM CEILING. EXHAUST OPENING WELDED GUSSETT 16 GAUGE WELDED CARBON STEEL 1/2" THREADED ROD DUCT SHALL BE INSTALLED WITHOUT FORMING DIPS OR TRAPS THAT MIGHT COLLECT RESIDUE. PROVIDE RADIUS ELBOW FITTING HOODS SHALL EXTEND A MINIMUM OF 6" BEYOND THE SIDES OF THE COOKING DEVICE AND A MINIMUM OF 12" OVER THE FRONT OF THE DEVICE. GREASE GUARD SHALL BE PROVIDED AROUND HOOD EXHAUST FANS. SEE KITCHEN HOOD EXHAUST DETAIL 4-M502. NOTES: 1. FOR ANSUL FIRE SUPPRESSION SYSTEM REQUIREMENTS REFER TO ANSUL FIRE SUPPRESSION PIPING DETAIL. 2. HOOD SYSTEMS SHALL BE DESIGNED AND INSTALLED IN STRICT ACCORDANCE WITH N.F.P.A. 96, UL STANDARD 300, AND ALL OTHER APPLICABLE CODES. HOOD FIRE EXTINGUISHING SYSTEM NOTES: 1. WHERE CEILING IS HIGHER THAN ROP OF HOOD, PROVIDE ANSUL FIRE EXTINGUISHING CABINET ONE END OF HOOD (REFER TO FLOOR PLAN FOR LOCATION). 2. WHERE CEILING IS NOT HIGHER THAN TOP OF HOOD, PROVIDE ANSUL FIRE CABINET MOUNTED ON WALL ABOVE CEILING (REFER TO FLOOR PLAN FOR LOCATION). 1 TO EXHAUST FAN 2 HOOD 3 MECHANICAL FUSIBLE LINK 450° F EXHAUST. 4 DISCHARGE NOZZLE IN EXHAUST. 5 DISCHARGE NOZZLE IN EXHAUST DUCT PLENUM BEHIND FILTERS 6 EXHAUST PLENUM 7 DISCHARGE NOZZLE OVER COOKING APPLIANCES. 8 ANSUL AUTOMAN W/ STORAGE TANK R-102 9 EMERGENCY PULL STATION WITH GUARDS. 10 AUTOMATIC GAS VALVE (2") OR ELECTRIC RELAY. * 11 COOKING APPLIANCE 12 3/8" BACK MALLEABLE PIPING. * FURNISHED BY HOOD MANUFACTURER/ANSUL AND INSTALLED BY PLUMBING SUBCONTRACTOR IF GAS OR BY ELECTRICAL SUBCONTRACTOR IF ELECTRIC. 1 2 4 5 6 7 8 9 11 3 412 7 3 REFER TO FLOOR PLANS FOR CABINET LOCATION LOCATE BY EXIT DOOR IF APPLICABLE 10'-0" MINIMUM REFERENCE M501 FOR HOOD MOUNTING HEIGHT REQUIREMENTS 10MOUNT PULL STATION AT 48" AFF ANSUL SYSTEM SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND ALL GOVERNING CODES. NOTES: 1. ROOF CURB SHALL BE INSTALLED DEAD LEVEL. LIFT CURB AS REQUIRED TO OFFSET ROOF SLOPE AND SECURE TO 16 GA. ANGLE WITH (2) #10 TEK SCREWS SPACED 24" MAX. ON CENTER. 2.SECURE 16 GA. ANGLE TO ROOF DECK WITH #10 TEK SCREWS SPACED 24" MAX ON CENTER. 3.FLASH & COUNTERFLASH ROOFING TO ROOF CURB. 4.ANGLE SHALL MATCH SLOPE OF ROOF FOR LEVEL UNIT INSTALLATION. NOTE 4 NOTE 2 NOTE 3 ROOF DECK ROOFTOP UNIT CURB NOTE 1 24" MAX FACTORY MOUNTED AND INSTALLED SMOKE DETECTOR. POWER FROM AC UNIT INTERLOCK TO SHUT DOWN UNIT ON ALARM. SYSTEM SENSOR. COMBINATION ALARM, TROUBLE, HORN & KEY TEST STATION. COMPATIBLE WITH FACTORY INSTALLED SMOKE DETECTOR. SCALE: SMOKE DETECTOR WIRING DIAGRAM NOT TO SCALE 10 NOTE: SUBMIT SHOP DWGS & DETAILS OF SMOKE DETECTOR INSTALLATION TO LOCAL BUILDING DEPT. & FIRE MARSHAL FOR APPROVAL PRIOR TO ANY WORK. NOTES: 1. ALL WIRING TO BE PER MANUFACTURER'S WIRING DIAGRAMS. 2.COORDINATE LOCATION OF SYSTEM SENSOR / KEY TEST STATION PRIOR TO INSTALLATION. PROVIDE LABEL INDICATING ASSOCIATED RTU UNIT SERVED. INSTALL ADJACENT T-STAT OR IN LOCATION APPROVED BY FIRE MARSHAL SIZE WIRE PER MANUFACTURER'S WIRING DIAGRAM. FLEXIBLE CONNECTION (TYP) ROOF UNISTRUT- SPACED AS REQUIRED 45 DEGREE TOP OPENING WITH 1/2" MESH SCREEN OVER OPENING. RTU 1 REFER TO STRUCTURAL DWGS. FOR JOIST LOCATIONS, SIZES, AND DIRECTION.2" ACOUSTIC LINING IN RETURN DUCT UP TO ROOFOPT UNIT. DUCT SIZES INDICATED ARE FREE AREA AND DO NOT INCLUDE LINING. 28 X 28 R.A. DUCT RTU 1 FLEXIBLE CONNECTION (TYP) ROOF 10 ' - 6 " DROP BOX DB-1. INSTALL PER MANUFACTURERS INSTRUCTIONS. MOUNT TIGHT TO BOTTOM OF JOIST. 18"Ø S.A. RUNOUT DUCT WITH SPIN-IN AIR SCOOP FITTING AND MVD. COORDINATE TAP LOCATION TO AVOID STRUCTURE 9' - 9 " SCALE: SECTION B ELEVATION NTS7 REFER TO STRUCTURAL DWGS. FOR JOIST LOCATIONS, SIZES, AND DIRECTION. ROOF L 4" X 4" X 1/4" XXX 2" ACOUSTIC LINING IN SUPPLY DUCT DOWN FROM ROOFTOP UNIT. DUCT SIZES INDICATED ON DRAWINGS ARE FREE AREA AND DO NOT INCLUDE LINING. REV. NO. SPCR NO. PROJECT LOCATION FILE NAME LAYERS DATE SCALE SHEET NO. DWG. TITLE OWNER USERNAME PROJECT NO. PLANNER KICK OFF MEETING ISSUED FOR 90% ISSUED FOR PERMIT FINAL APPROVED PLAN RECORD DRAWINGS DRAWN BY CHECKED BY GETGO #3557 4927 EAST 146TH STREET 261 KAPPA DRIVE, DATE REVISIONS BY ISSUED FOR REDLINE REVIEW GIANT EAGLE, INC. 750 HOLIDAY DRIVE, SUITE 200 PITTSBURGH, PA 15220 PHONE: 412-921-4300 FAX: 412-921-4313 PITTSBURGH, PA 15238 2016003.00 01-20-15 CARMEL, IN 46062 02-26-16 02-26-16