HomeMy WebLinkAbout2016-10-31_Lighting Compliance Certifcate.pdfInterior Lighting Compliance Certificate
Project Title:
90.1 (2007) Standard
Project Type:Alteration
Construction Site:Owner/Agent:Designer/Contractor:
Project Information
Energy Code:
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
(B X C)
1-dinning Area (Common Space Types:Dining Area - Family Restaurant)4581 2.10 9620
2-Restrooms (Common Space Types:Restrooms)443 0.90 399
3-Kitchen Area (Common Space Types:Food Preparation)1412 1.20 1694
4-Sprinkler Room (Common Space Types:Electrical/Mechanical): Exempt
11713Total Allowed Watts =
Area Category Exemption Qualifications
Activity Area
# Fixtures
Repl./AddedPre-Alt.null
Total # Watts
Pre-Alt.Post-Alt.
Sprinkler Room ( Common Space
Types:Electrical/Mechanical 80 sq.ft.)
45 0
Exemption: Less than 50% fixture replacement.
45.000 0.000
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
dinning Area ( Common Space Types:Dining Area - Family Restaurant 4581 sq.ft.)
LED: D2: Recessed LED Downlight: Other:1 11 17 184
LED: D1: Monopoint light: Other:1 8 14 112
Incandescent: P1: Decorative Light: Incandescent 100W:1 25 13 325
Incandescent: P2: Decorative Light: Incandescent 60W:1 13 100 1300
Incandescent: P3: Decorative Light: Incandescent 75W:4 3 100 300
Incandescent: W1: Decorative Light: Incandescent 100W:1 17 75 1275
Incandescent: W2: Decorative Light: Incandescent 100W:1 4 60 240
Restrooms ( Common Space Types:Restrooms 443 sq.ft.)
LED: D2: Recessed LED Downlight: Other:1 12 17 200
Kitchen Area ( Common Space Types:Food Preparation 1412 sq.ft.)
LED: A1: 2'x4' LED Troffer: Other:1 17 34 578
LED: D2: Recessed LED Downlight: Other:1 9 17 150
Sprinkler Room ( Common Space Types:Electrical/Mechanical 80 sq.ft.): Exempt
4664Total Proposed Watts =