HomeMy WebLinkAbout16100110 Building Plans�
, • .
� . , � � � . � , . ,
VICI�ITY �AP
<!�l/J///�
N
► ' �\
�
�
TRUE
NORTH
OF SCOPE
�' � �
GENERAL
G000 COVER SHEET
G001 LIFE SAFETY P�AN
G002 ANSI 117.1 ACCESSIBILITY DETAILS
G003 ANSI 117.1 ACCESSIBILITY DETAILS
I NTERI OR ARCH ITECTU RE
IA001 GENERAL NOTES AND SYMBOLS
IA101 CONSTRUCTION PLAN
IA201 REFLECTED CEI�ING P�AN (LOCATION ONLY)
IA251 ELECTRICALIDATA PLAN (LOCATION ONLY)
IA601 INTERIOR ELEVATIONS
IA602 SECTIONS/DETAILS
IA701 FINISH PLAN AND SCHEDULE
P ROJ E CT T EA�
• �
.
!' • •: • •
� .1 • . .�.�
.•
. �
. .� . . � . �
EQUIPMENT PROVIDER
HENRY SCHEIN
MIKE WOOD- EQUIPMENT AND TECHNOLOGY SPECIALIST
5315 W 74TH STREET #300
INDIANAPOLIS, IN 46268
PHONE: 317-538-5314
EMAIL: MIKE.WOOD@HENTRYSCHEIN.COM
� .� �.
� ���������
. � - . . .
. � � . . ..
• • ••
INTERIOR DESIGNER
MITSCH DESIGN
KATIE DIVINE - SENIOR PROJECT MANAGER
200 SOUTH RANGE�INE ROAD, STE 213
CARMEL, IN 46032
PHONE: 317-573-2222
EMAIL: KDIVINE@MITSCHDESIGN.COM
ARCHITECT
MITSCH DESIGN
STUART SHADE - PRINCIPAL OF ARCHITECTURE
200 SOUTH RANGE�INE ROAD, STE 213
CARMEL, IN 46032
PHONE: 317-573-2222
EMAIL: SSHADE@MITSCHDESIGN.COM
�
200 s rangeline road
suite 213
carmel, indiana 46032
ph 317.573.2222
fx 317.573.2230
www.mitschdesign.com
W
U
LL
W
0
J
�
z
W
0
�
�
o�
o Z
m U > I_
� � W �
d'ZF- (n2i
oOZQ�z
0
wWU���
U Q � � � ~
��J�K
� Z Q m J W
_
�
zQUztti�
���a��
�o����
z � � � O a
¢=ow�x
(nF }m W W
Z t-�=fn
wp°'�O�
o��LL��
viWaWp�
�� �- J W W
�ao¢ c�
�wz=�x
a�a<now
�
�
z
Wc
G
�
U
�
0
�
�
z
0
U
�
�
�
f
�
�
W
�
J
�
�c
G
m
�
�
W
H
�
(J�
DWG SCALE:
DRAWN BY:
CHECKED BY:
MD PROJECT #
�
�•
��
1 • �
�
•i :
9 9 9 0 9 9 9
COVER
SHEET
II / 'TO EXIT
tl_�/ �
'
�
EXIT
_ � � �, ��/
, ,,,
- ,,
, ; „ ,
i,' �� ` �'�
/ >\ � I
�
� ' � ,� �
K� i I
i
I
`�j
,- ��
, ,
i � �
r �
�— � �� , ,_j� EXIT
� �
I � `�� i� i � i
�� ��� ,�� ��, �TO EXIT � �� i —
� ri rrri�ii ��t���l��i' _ � T � ��� -'� �
� � 1
;�\` �� I I � ITO EXIT \TO EXIT �
� � �
��—
�
,- TO EXIT j � I ,
�'�_ �� � � � �%�//�.1// _/l/�/// .1/ ���� BEVERAGE
' I - STATION
� �' ^ �
�'�_ �� � % � � \ �
` �TO EXIT �� -,' `� �
� �
,
� ' � �
i� �
' �
� � _
� � '� �
�
I I � ' /
, �� ,,� �
��r �/�'�r�rr��ii���ir��� 'I
I �
TO EXIT � TO EXIT TO EXIT � TO EXIT TO EXIT TO EXIT
TO EXIT � � � � � �
�
( c====�
%+, I
I ✓.
� �, I
I I /, I
� TO EXIT � 1� .}
� �, _ � �. � /' ry �
-RAY
�
LIFE SAFETY PLAN - FIRST FLOOR 0 0 0 0 r,
SCA�E: 1l4"=1'-0" �
� TRUE
NORTH
�
X-RAY
�
Q►�:Y1
EXIT
�IFE SAFETY �EGEND
OFEB FIRE EXTINGUISHERAND CABINET
Q FEB FIRE EXTINGUISHER AND WALL BRACKET
' � DENOTES DIRECTION OF EGRESS
NOTE: COORDINATE FINAL FIRE EXTINGUISHER LOCATIONS WITH �OCAL FIRE CHIEF
CODE ANA�YSIS
1 BUILDING CONSTRUCTION TYPE VB
2 OCCUPANCY C�ASSIFICATION B- BUSWESS
3 FIRE SUPRESSION SYSTEM NONE
4 EXISTING BUILDING HEIGHT 1 STORY
5 EXISTING BUILDING AREA FIRST: 19,731 SQUARE FEET
6 PROPOSED BUILDING AREA FIRST: 2,833 SQUARE FEET
7 PROPOSED OCCUPANT �OAD AREA 2,833 FACTOR 100 = LOAD 28 (1004.1.2)
8 PROPOSED USE OF FACILITY DENTA� OFFICE
9 EXITS REQUIRED 1 (TABLE 1015.1 }
10 RATED STORAGE ROOMS NO
11 FtATED CORRIDORS NO (1018.1 EX. 4)
�2 OCCUPANCY SEPARATION REQUIRED DNA
13 ENCLOSED STAIRS REQUIRED DNA
APPLICAB�E CODES
CODE DESCRIPTION COMPRISED OF
GENERA� ADMINISTRATION GENERAL ADMINISTRATION 675 IAC 12
RULES RULES (GAR) (UPDATED 8/1 /2014)
(AMENDED 12l1 /2014)
BUILDING CODE 2014 INDIANA BUILDING CODE (675 2012 INTERNATIONAL
(INDIANA AMENDMENTS) IAC 13-2.6) BUI�DING CODE
EFFECTIVE DECEMBER 1, 2014 675 IAC 13-2.6
FIRE CODE 2014 INDIANA FIRE CODE (IFC) 2012 INTERNATIONAL FIRE CODE
(INDIANA AMENDMENTS) EFFECTIVE DECEMBER 1, 2014 675 IAC 22-2.5
PLUMBING CODE 2012 INDIANA PLUMBING CODE 2006 INTERNATIONA� PLUMBING
(INDIANA AMENDMENTS) (IPC) CODE
EFFECTNE DECEMBER 24, 2012 675 IAC 16-1.4
ELECTRICAL CODE 2009 INDIANA ELECTRICAL CODE (IEC) 2008 NFPA 70
(INDIANA AMENDMENTS) EFFECTIVE AUGUST 26, 2009 675 IAC 17-1.8
MECHANICAL CODE 2014 INDIANA MECHANICAL CODE (675 2012 INTERNATIONAL MECHANICA�
(INDIANA AMENDMENTS) IAC 18-1.6) EFFECTIVE DECEMBER 1, CODE
2014 675 IAC 18-1.6
HANDICAPPED ACCESSIBILITY 2014 INDIANA BUILDING CODE 675 IAC 13-2.6-12 CHAPTER 11
CODE (INDIANA AMENDMENTS) CHAPTER 11 - ACCESSIBILITY A117.1 ACCESSIBLE AND USABLE
BUI�DINGS AND FACILITIES, 2009
EDITION
ENERGY CODE 2010 INDIANA ENERGY CONSERVATION ASHRAE STANDARD 90.1, 2007
(INDIANA AMENDMENTS) CODE (IECC) 675 IAC 19.3
EFFECTIVE MAY 7, 2010
ELEVATOR SAFETY CODE 2011 INDIANA ELEVATOR SAFETY CODE 675 IAC 21 - ANSI / ASMEA17.1, 2007
(IESC) ANSI / ASME A90.1, 2003
(UPDATED 9-28-11) ANSI / A10.4, 2004
ASME / A18.1, 2005
BUILDING REHABILITATION INDIANA BUILDING REHABILITATION 675 IAC 12-8
STANDARD STANDARD(GAR)
(INDIANA AMENDMENTS) (UPDATED 12.22.06)
(REPEALED JUNE 18, 2008
SANITARY CODE 1998 AMERICAN SOCIETY OF 675 IAC 16-2
(INDIANA AMENDMENTS) SANITARY ENGINEERS STANDARD
1051
D� S I G N
200 s rangeline road
suite 213
carmel, indiana 46032
ph 317.573.2222
fx 317.573.2230
www.mitschdesign.com
W
U
�
�
O
J
�
Z
W
0
0 0 0 0 0 0 0
�
�
o �Z
mU > 1-
o ��
w ��
�z�
oozQ�z
0
wWU���
U Q � � � ~
� � W J � �
ZZ�p�� LL1
d
zQ2
Uztti�
���a��
ao��cn�
z � � � O a
¢=ow�x
(nF }m W W
C7} ��Z� W
wp°'�O�
o�°�-��
viWaWp�
�� �- J W W
�ao¢ c�
�wz=�x
a�acnow
�
�
z
W
�
�
U
O
0
�
�
Z
�
U
�
�
�
�
H
W
�
J
�
�c
G
m
�
�
W
H
H
�
DWG SCALE:
DRAWN BY:
CHECKED BY:
MD PROJECT #
��
e e e e e e e
AS NOTED
JS / ZH
KD
16078
0 0 0 0 9 0 0
LIFE
SAFETY PLAN
- /: ' � ��� � •
, ;Y ';ia;} � „ �.. . ...
�.,�b, ,..s.�.v,� ...,,�x>.`4§�`��'� � e`��'��U;�i�����sW��Y: ��k���.�������t�„tr,�s§ :, ����,�,�.�.����� `�.?�t:.�
��������� �� � ■ ��� ��
(c)
(a} Front Approach
� �
� �
� �
i i
I I c
I I ��
I I U
i i �
i i �
i �
22inch min �
I
�
(b) Pocket or Hinge Approach
Door Width �� 48 inch min
Door Width
�
(a)
Figure 404.2.5
Two Doors in Series
MINIMUM CIEARANCES
APPROACH DIRECTION
Perpendicular to Doorway �>>
From Front 48 inches
From Side 42 inches
NOTES:
(1) Maneuvering space shall include full width of tloorway.
Table 404.2.3.4 -- Maneuvering Clearances for poorways without
Doors
� �
I I
I I
I I
� I I
�� I � I
L � �
� I I
N I I
v I I
I I
� �
I I
� �
(b) Side Approach
r �
� �
� �
� �
_ � �
�� � �
� i i
° I I
� i i
� I I
� �
i i
i i
� �
;..,�'�'..,.� 4
(a) Front Approach
Figure 404.2.4.4 -- Maneuvering Clearances
at Doorways without Doors
r -�
I �
i
I
I
I I
� I I
(a} Front Approach, Pull Side
r —i
I I
I � I
I I
� �
� �
� �
r �
I
I I
�
� I I
'� I
L I I
V I I
C I
7 III
I 24 inch min
�
{c) Stop or �atch Approach
Figure 404.2.3.3 -- Maneuvering Clearances at Sliding and
Folding Doors
MINIMt1M CIEARANCES
APPROACH DIRECTI4N
Perpendicular ta Door ��� Parallel to Door
From Front 48 inches 0 inches
From Non-�atch Side 42 inches 22 inches �z�
From �atch Side 42 inches 24 inches �z>
NOTES:
(1) Maneuvering space shall include full width of doonvay.
(2) From latch side towards the doorway
Table 404.2.3.3 -- Maneuvering Clearances for Sliding and
Folding Doors
Note: Revolving doors or turnstiles shall not be part of an accessible route.
404.2.1 Double-Leaf Doorwa s. At least one of the active leaves of doorwa s with two inde endentl o erated leaves shall com I with ICC/ANSI A117.1-2009 Sections 404.2.2 and 404.2.3.
Y Y P Y p PY
404.2.2 Clear Width. Doorways shall have a clear opening of 32 inches minimum. Clear opening of doorways with swinging doors shall be measures between the face of door and stop, with the door open 90°.Openings more than 24 inches deep shall provide a
clear opening of 36 inches minimum. There shall be no projections into the clear opening width lower than 34 inches above the floor. Projections into the clear opening width between 34 inches and 80 inches above the floor shall not exceed 4 inches. (Fig.
404.2.3)
404.2.3.4 Maneuvering Clearances at Doors. (See ICC/ANSI A117.1-2009 Tables 404.2.3.2, 404.2.3.3 and 404.2.3.4; and see Figs. 404.2.4.1, 404.2.4.2 and 404.2.6)
404.2.3.2 Swinging Doors. Swinging doors shall have maneuvering clearances complying wifh ICGANSI A117.1-2009 Table 404.2.3.2.
404.2.3.3 Sliding and Folding Doors. Sliding Doors and folding doors shall have maneuvering clearances complying with ICC/ANSI A117.1-2009 Table 404.2.4.2.
404.2.3.4 Doorways without Doors. Doorways without doors that are less than 36 inches wide shall have maneuvering clearances complying with ICC/ANSI A117.1-2009 Table 404.2.3.3.
404.2.3.5 Recessed Doors. Where the plane of the doorway is recessed clearances for front approach shall be provided.
404.2.4.5 Floor or Ground Surfaces. Floor or ground surfaces within the maneuvering clearances shall have a slope not steeper than 1:48 and shall comply with ICC/ANSI A117.1-2009 Section 302.
404.2.4 Thresholds at Doorways. Thresholds, if provided, at doorways shall be 1/2 inches high maximum. Raised thresholds and changes in level at doorways must comply with ICC/ANSI A117.1-2009 Sections 302 and 303.
Exception: An existing or altered threshold shall be permitted to be 3/4 inch maximum in height provided that the threshold has a beveled edge on each side with a maximum slope of 1:2 for the height exceeding 1l4 inch.
404.2.5 Two Doors in Series. Distance between two hinged or pivoted doors in series shall be 48" minimum plus the width of any door swinging into the space.
404.2.6 Door Hardware. Handles, pulls, latches, locks and other operable parts on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching or twisting of the wrist to operate. Such hardware shall be
34" minimum and 48" maximum above the floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Exception: Locks used only for security purposes and not used for normal operation are permitted in any location.
' � i� /�� . � 1�� .
� i � `
(c) Hinge Approach, Pull Side
/�� ' I 12inch min*
� ,
i i � i
i i i
i i
� i i i
� i i
� i i i
" � I� i i ,
22inch min
---�
(e) Hinge Approach, Push Side
*If both closer and Iatch are provided
"48" min. where both closer and latch are provided
r--T �
I I I
I I � I
I I I
I I I �
I �
12 inch min* .� .� � c
/� /
I I I �
I I I
I I I
I I I
�� �
n
(b) Front Approa Push
Slde
` Where both closer and latch are provided
(d) Hinge Approach, Pull Side
r �
� �
� �
i i
�i i
� i i
�i i
� i i
� i i
�
24inch min
* 4$" min. where closer is provided
� �
I I
I I
I I
I I �
1 I �E
I I �
I I �
� I �
24 inch min � I
(f} Latch Approach, Pull Side
* 54" min. where closer and is provided
(g) �atch Approach, Push Side
*48 minimum if closer is provided
Figure 404.2.3.2
Maneuvering Clearances at Swinging Doors
TYPE OF USE MINIMUM CLEARANCES
Approach Door Perpendicular to Door ��� Beyond Latch Parallel to Door
Direction Side
From Front Pull 60 inches 18 inches
From Front Push 48 inches 0 inches �z�
From Hinge Side pup 60 inches 36 inches
54 inches 42 inches
From Hinge Side Push 42 inches �s� 22 inches
From Latch Side Pull 48 inches �n> 24 inches
From Latch Side Push 42 inches �a> 24 inches
NOTES:
(1) Maneuvering space shall include full width of doorway.
(2) Add 12" if closer antl Iatch providetl.
(3) Add 6" if closer and latch provided
(4) Add 6" if closer provided.
Table 404.2.3.2 -- Maneuvering Clearances of Manual Swinging
Doors
32 inches min
(a) Hinged Door
� 36 inches min �
(d) Opening without Door
32 inches min
(b) Sliding Door
32 inches min �
i
(c) Folding Door
Figure 404.2.3
Clear Width of Doorways
x
m
E
�
M
20 inch max
10" max
-- �
.� x
� � �
- � E
� �
_ —_ � U
/ C
""""_"""' � N
� �
O
\ , ,
Figure 308.2.1
Unobstructed Forward Reach
>20-25 inches max
Figure 308.2.2
Obstructed High Forward Reach
Figure 308.3.1
Unobstructed Side Reach
Figure 308.3.2
Obstructed High Side Reach
> 10"-24" max
308.2 Forward Reach.
308.2.1 Unobstructed. Where a clear floor space complying with ICC/ANSI A117.1-2009 Section 305 and the forward
reach is unobstructed, the high forward reach shall be 48 inches maximum and the low forward reach shall be 15 inches minimum
above the floor.
3Q8.2.2 Obstructed High Reach. Where a clear floor space complying with ICC/ANSI A117.1-2009 Section 305 and the
a high forward reach is over an obstruction, the clear floor or ground space shall extend beneath the element for a distance not
less than the required reach depth over the obstruction. The high forward reach shall be 48 inches maximum where the reach
depth is 20 inches maximum. Where the reach depth exceeds 20 inches, the high forward reach shall be 44 inches maximum and
the reach depth shall be 25 inches maximum.
308.3 Side Reach.
30$.3.1 Unobstructed. Where a clear floor space complying with ICC/ANSI A117.1-2009 Section 305 and allows a
parallel approach to an element and the edge of the clear floor space is 10 inches maximum from the element, the high side
reach shall be 48 inches maximum and the low side reach shall be 15 inches minimum above the floor.
308.3.2 4bstructed High Reach. Where a clear floor space complying with ICC/ANSI A117.1-2009 Section 305 and
allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34
inches maximum above the floor and the depth of the obstruction shall be 24 inches maximum. The high side reach shall be 48"
maximum above the floor for a reach depth of 10 inches maximum. Where the reach depth exceeds 10 inches, the high side
reach shall be 46 inches maximum above the floor for a reach depth of 24 inches maximum.
1 ' ' � • • � • � � •
' � � '
.
rn i
D E S I G N
200 s rangeline road
suite 213
carmel, indiana 46032
ph 317.573.2222
fx 317.573.2230
www.mitschdesign.com
�
UQ
- J
� Q
� T
Z -'-
W �
U�
W �
� �
� ,
� �
�/ / �
�
r
�
�
�
� M
Q
� �
W �
; Z
� W
O �
Cfl �
l.f) Q
�U
�
� �
o °z
m U > �
�� W�
w ��
W
oW���W
QQ����
zZom�w
x
a
a�c�na�v�
ao��in�
z � LL � O a
¢=ow�x
�,�}mWW
z �o=�n
w�a�0�
olaWoa
W�=>��
�aoaWCW.�
J W Z S� X
a�a�now
�
�
Z
W
� w
� �
U
J
� �
H �
� �
Z pp
O
U �
� W
� �
v �
� �
DWG SCALE:
DRAWN BY:
CHECKED BY:
MD PROJECT #
• • • • •� • •
AS NOTED
JS / ZH
KD
16078
•• • • • • •
ANSI 117.1
Accesibility Details
24 inches max � 24 inches max
48 inches min
�
�
� � � �
s .�c O ) .�c .�c
c c ) c c
M M M M
�
�
Figure 403.5
Clear Width of an Accessible Route
Segment Length Min. Segment Width
Less Than or Equal to 24 inches 32 inches (See Note)
Greater Than 24 inches 36 inches
Note: Consecutive segments of 32 inches wide must be separated by a route segment 48 inches long minimum and 36
inches wide minimum.
Table 403.5
Clear Width of an Accessible Route
ANSI 117.1403.5 Clear Width of an Accessible Route
... . . . .
SCALE: NOT TO SCALE
60 inch min -
,'' `�
� `
� ��
� �
; `� 304.3.1: Circular Space
,� � The turning space shail be permitted to
i �
include knee and toe clearance
� � complying with ICCIANSI A-117.1-2009 Section 306.
� ;
� ,
� '
� '
� �
� �
� �
� �
, ,
(a) Circular
Figure 304.3
Size of Wheelchair Turning Space
60 inch minimum
304.2 Floor or Ground Surface. Floor or ground surfaces of a wheelchair turning space shall have a slope not steeper
than 1:48 and shall comply with ICC/ANSI A117.1-2009 Section 302.
304.3 Size. Wheelchair turning space shall comply with ICC/ANSI A-117.1-2009 Sections 304.3.1 or 304.3.2. (Fig. 304.3)
, / � � r � � i �
�� PAPER
TOWEL MIRROR
DISPENSER
0 �
�zv
O �' Q
C.�
{~— W �
mW(n
O �
�
3.2: T-Shaped Space
� arm of the T shall be ciear of obstructions. The
ng space shall be permitted to include knee
tow clearance complying with
4NSI A-117.1-2009 Section 306 only at the end
ther the base or one arm.
ANSI 117.1 WheelcahirTurning Space
000 0 0 0 0
SCA�E: NOT TO SCA�E
ALL ACCESSIBLE SIGNAGE AND SIGNS
ON DOORS PROVIDED BY GC
TOWEL DPR/ TOILET SEAT
URINAL
_�
�� --- �71
�
GRAB BAR
WA�L MOUNTED
LAVATORY
Typical Fixture Accessibility Detail
SCA�E: NOT TO SCALE
■
��� '
D� S I G N
200 s rangeline road
suite 213
carmel, indiana 46032
ph 317.573.2222
fx 317.573.2230
www.mitschdesign.com
W
U
�
�
O
J
�
Z
W
0
�
�
o�
o Z
?N U > 1-
� � W �
KZI- UJ2i
oOZQ�Z
0
wWU���
U Q � � � ~
o�Wm�W
Z�—�a
ZQ_
Uzui�
���a��
aof=�cn�
z � � � O a
Q=ow�x
(nF }m W W
�}���W
wp°'�O�
oF��-cnrt
viWaWp�
�� �- J W W
�ao¢ c�
�wzx�x
a�a<now
�
�
z
W
� �
U
J
� �
H �
� �
Z
m
� �
� W
� Q
rn in
DWG SCALE:
DRAWN BY:
CHECKED BY:
MD PROJECT #
�
��
AS NOTED
JS / ZH
KD
16078
ANSI 117.1
Accesibility Details
� , ,
r�
�
� �� �
>� I �
N� I
( - 3" VENT TO MAIN
( r I B�DG.VENT
( I
( I
( I
� �
I
1 I �AV
2" WASTE
C.O// (
PLl1MBING RISER DIAGRAM (TOILET)
00 0 0 0 0 0
SCALE: NOT TO SCALE
i
N
���
�
2" VENT TO
MAIN BLDG. VENT
� � ■ ■ r � � � j�Tf►�I
� ��lt�
SCALE: NOT TO SCALE
-�- UNDERSIDE OF SLAB OR STRUCTURE ABOVE
METAL CLOSURE ANGLE SEALED WITH
FIREPROOF SEALANT
CEILING RS SCHEDULED, REFER TO
REFLECTED CEILING PLAN
3 5/8" METAL STUDS, 16" O.C. WITH 5/$" TYPE
"X" GYPSUM BOARD BOTH SIDES. (TO BE
CONSTRUCTED TO MEET 1 NOUR FIRE RATING
IN ACCORDANCE WITH LOCAL, STATE, AND
INTERNATIONAL BUILDING CODES LATEST EDITION)
U� APPROVED GLASS FIBER BATT
FOR 1 HOUR FIRE PARTITION
-1-1/2" HAT TRACK 2" O.G FROM FLOOR AND 6" O.C.
FROM CEILING. 24" O.C. SPACING BETWEEN HAT TRACKS
BASE - SEE SCHEDULE FOR SPECIFICATIONS
CONTINUOUS FIREPROOF SEALANT
FLOOR LINE
1 FIOUR FIRE PARTITION -SOUND DEADINING (INSULATED)
0 0 . o . o 0
SCALE: 314"=1'-0"
�
w
�
SOLID SURFACE CAP; SEE IA601 FOR
MORE DETAILS
SEAL JOINT BETWEEN SOLID SURFACE
CAP AND DRYWALL
WOOD NAILER BOARD FOR TOP CAP
3 5/8" METAL STUDS, 16" O.C. WITH 5/8"
GYPSUM BOARD BOTH SIDES
BASE - SEE SCHEDU�E FOR SPECIFICATIONS
FLOOR LINE
PARTIAL HEIGHT WALL (TYP.
SCALE: 314"=1'-0"
SEE SCHED
i�_i
�
w
S
U
�
w
W
�
TYPE #1
SOLID WOOD
DOOR
FRAME TYPES
SEE SCHED
��--��
0
w
S
U
�
w
�
TYPE #1
HOLLOW META�
SEE SCHED
i----i
0
W
S
U
�
W
W
�
TYPE #2
SOLID WOOD
DOOR, GLASS
KIT
SEE SCHED
("�..'
0
0
w
S
U
�
w
�
TYPE #2
DRYWALL WRAP
WITH SLIDING
DOOR TRACK
HARDWARE LEGEND
#1 PASSAGE LATCH #2 ENTRYIEXIT OR
OFFICE LOCKSET
0 o m o m o m 1 LEVER HANDLE
PASSAGE LATCH SET 1 �EVER HAND�E
1 DOOR STOP OFFICE �OCKSET
3 SILENCERS 1 DOOR STOP
3 SILENGERS
UNDERSIDE OF SLAB OR STRUCTURE ABOVE
METAL CLOSURE ANGLE SEALED WITH
FIREPROOF SEALANT
CEILING AS SCHEDULED, REFER TO
REFLECTED CEILWG PLAN
3 5/8° META� STUDS, 16" O.C. WITH 5/8" TYPE
"X" GYPSUM BOARD BOTH SIDES. (TO BE
CONSTRUCTED TO MEET 1 NOUR FIRE RATING
IN ACCORDANCE WITH LOCAL, STATE, AND
INTERNATIONAL BUILDING CODES LATEST EDITIdN}
UL APPROVED GLASS FIBER BATT
FOR 1 HOUR FIRE PARTITION
BASE - SEE SCHEDULE FOR SPECIFICATIONS
CONTINUOUS FIREPROOF SEALANT
FLOOR LINE
1 HR PARTITION TO DECK (INSl1LATED)
.. . � . . .
SCALE: 314"=1'-0"
UNDERSIDE OF SLAB OR STRUCTURE ABOVE
/ INSULATION ABOVE CEILING GRID 2'-0"
ON EACH SIDE OF WALL
CEILING AS SCHEDULED, REFER TO
REFLECTED CEILING PLAN
3 5/8" METAL STUDS, 16" O.C. WITH 5/8"
GYPSUM BOARD BOTH SIDES
INSULATION IN WALL CAVITY
BASE - SEE SCHEDU�E FOR SPECIFICATIONS
CONTINIOUS ACCOUSTICAL SEALANT
FLOOR LINE
PARTITION TO CEILING �INSULATED)
0 o s e s o 0
SCALE: 314"=1'-0"
#5 STORAGE LOCKSET
1 LEVER HANDLE
STORAGELOCKSET
1CLOSER
1 DOOR STOP
3 SI�ENCERS
DOOR SCHEDULE
DOOR
SIZE
NO. W�DE HGT THICK TYPE FINISH RATI
101 3'-0" 7'-0" 1-3/4" 3
103 3'-0" 7'-0" 1-3/4" 2
104 3'-0" 8'-0" 1-3/4" 2
105 3'-0" 7'-0" 1-3/4" 1
113 3'-0" 8'-0" 1-3/4" 2
116 3'-0" 7'-0" 1-3/4" 1
117 3'-0" 7'-0" 1-3/4" 1
118 3'-0" 7'-0" 1-3/4" 1
119 3'-0" 7'-0" 1-3/4" 1
122 3'-0" 7'-0" 1-3/4" 1
123 3'-0" 7'-0" 1-3/4" 4
124 3'-0" 7'-0" 1-3/4" 1
�••� • �
SEE SCHED
i----i
0
W
S /
U /
�
W
W
�
TYPE #3
G�ASS DOOR
SEE SCHED
�
a
W
S
U
�
W
�
TYPE #3
STEEL1HR
FIRE RATED
#3 SLIDER PUL�
1 PULL/ FLUSH
HANDLE SET
1 WA�� MOUNTED
S�IDING TRACK
SET
.,
If 7111� 1[+'9: � 1:7_tr
G�ASS N/R N/A N/A
STAIN N/R 1 PT=2
STAIN N/R 2 N/A
STAIN N/R 1 PT-2
STAIN N/R 2 N/A
STAIN N/R 1 PT-2
STAIN N/R 1 PT-2
STAIN N/R 1 PT-2
STAIN N/R 1 PT-2
STAIN N/R 1 PT-2
PT-2 1 HR 3 PT-2
STAIN N/R 1 PT-2
SEE SCHED A THE GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS AND TEMPORARY DOORS
�----) AS INDICATED ON THIS DEMOLITION P�AN, OR AS DEEMED NECESSARY BY THE ARCHITECT AND
OWNER. THEY SNA�� BE MAINTAINED AND REPAIRED IMMEDIATE�Y IF ANY DAMAGE OCCURS. THESE
� DOOR ARE TO AVOID MIGRATION OF DUST INTO THE ADJOINING AREAS.
W
S
� B GENERA� CONTRACTOR TO VERIFY DUCTWORK OR PIPING PENETRATIONS THROUGH WAL�S ABOVE
WCEILING. IF PENETRATIONS OCCUR AND DUCTWORK OR PIPING IS TO BE REMOVED OR RELOCATED,
cn FILL IN OPENINGS TO BE F�USH WITH AND OF THE SAME MATERIAL AS THE SURROUNDING WALL.
C MAKE A�� DEMOLITION CLEAN AND COMP�ETE IN A MANNER SUITAB�E TO ACCEPT NEW SPECIFIED
TYPE #4 FINISNES AND OR SURFACES. REFER TO ARCHITECTURAL PLANS, SPECIFICATIONS, AND DETAI�S FOR
STEE� 1 HR. FIRE SPECIFIC INFORMATION REGARDING APPLICATION OF NEW MATERIAL.
RATED DOOR
ARCHITECTURAL NOTES
#4 PRIVACY �OCKSET
1 LEVER HANDLE
PRIVACY LOCKSET
1 C�OSER
1 DOOR STOP
3 SILENCERS
'�'�I��'7
1�'����
. �. �
"NOTE_E"
°NOTE C" °NOTE_D"
"NOTE E"
"NOTE_E;;
"NOTE_C "NOTE_D"
"NOTE_E"
"NOTE_E"
"NOTE_E"
"NOTE_E"
"NOTE_E"
"NOTE_E"
"NOTE_E"
"NOTE_E"
A REFER TO SHEET IA001 FOR DOOR TYPES AND WALL DETAILS.
B DOORS NOT INDICATED BY DOOR NUMBER DESIGNATION ARE EXISTING.
C S�IDING DOORS TO HAVE THIS HARDWARE OR APPROVED ALTERNATIVE: STRONGAR HARDWARE
SH-FPH-S-01 PULL/FLUSH HANDLE SET IN SATIN FINISH (HANDLE ON GORRIDOR SIDE); TORCH- WF
SERIES FACE MOUNTED TRACK SYSTEM GRF-WF-01, FOR 1.75° DOOR, 7' TRACK.
D GLASS INSERT TO RECEIVE 3M GLASS FI�M: I��UMINA-G (SH2FGIM-G); GRADATION PATTERN: 100%
DENSITY AT BOTTOM, 0% DENSITY AT TOP OF GLASS.
E DOORS ST,4INED TO MATCH PL-1; DESIGNER TO APPROVE FINAL CO�OR PROVIDED BY THE
CONTRACTOR
(1) 200 AMP WESTINGHOUSE
MAIN BREAKER PANEL
�0 AMP
�EC PANEL
AMP
2" PVC �
2" PVC
2/0 COPPER RISER UNDERGROUND
#4 BARE FEEDER WIRES
COPPER GROUND
� ' 1/2" X 8' GROUND ROD
E�ECTRICAL RISER
o a o 0 o a o
SCA�E: NOT TO SCALE
A ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES,
RULES, REGU�ATIONS AND STANDARDS, INCLUDING, BUT NOT LIMITED TO: THE INDIANA BUILDING
CODE, THE INDIANA CODES, THE INDIANA FIRE CODES, THE AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUI�DING CODE, AND APPLICABLE TRADE STANDARDS. ALL APP�ICABLE RULES AND
REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITIONS.
B THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING A�� CONDITIONS AND DIMENSIONS PRIOR
TO THE START OF WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT/DESIGNER IMMEDIATELY.
C THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL STATE AND LOCA� PERMITS REQUIRED FOR
COMP�ETION OF THIS PROJECT.
D ALL WORK IS TO BE COORDINATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT, FINISH,
SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE REQUIREMENTS OF
THE OWNERS F.F.E.
E A�L DIMENSIONS ARE SHOWN ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMED
QUESTIONABLE ARE TO BE VERIFIED WITH THE ARCHITECT/DESIGNER. DO NOT SCA�E DIMENSIONS
ON THE DRAWINGS. ALL DIMENSIONS ARE TO THE FACE OF GYPSUM BOARD, MASONRY/CONCRETE
WALLS, OR CENTER�INE OF COLUMNS UN�ESS NOTED OTHERWISE.
F CONTRACTOR IS TO SIGN EACH SHOP DRAWING SUBMITTA� HAS BEEN REVIEWED, APPROVED, AND
THAT THE CONTRACTOR COORDINATION HAS BEEN PERFORMED.
G DURING THE ENTIRE PERIOD OF CONSTRUCTION, ALL EXISTING EXITS, EXIT �IGHTING, FIRE
PROTECTIVE DEVICES, AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.
H FINISHED DOOR OPENINGS IN NEW PARTITIONS SHA�� BE SET 4" FROM ADJACENT PERPENDIGULAR
PARTITIONS, UNLESS OTHERWISE NOTED.
I AL� FINISH CARPENTRY IS TO BE COMP�ETED IN STRICT ACCORDANCE WITH A.W.I. STANDARDS,
PREMIUM GRADE.
J ALL FIRE EXTINGUISHER CABINET LOCATIONS ARE TO BE COORDINATED WITH THE CONTRACTOR,
DESIGNER AND THE LOCAL FIRE OFFICIALS PRIOR TO INSTA�LATION.
K CONTRACTOR(S) SHALL PROVIDE AL� NECESSARY �ABOR, MATERIA�S, AND EQUIPMENT FOR THE
WORK IN THESE DOCUMENTS, UNLESS CLEARLY NOTED "NOT IN CONTRACT° (N.I.C.). EXISTING WORK
ADJACENT TO OR IN THE AREA OF NEW WORK SHALL BE PROTECTED BY ALL SUITABLE MEANS
NECESSARY TO PREVENT OR MINIMIZE DAMAGE. WHERE EXISTING WORK IS TO BE REMOVED OR
ALTERED, RESTORE ADJACENT FINISH TO ORIGINAL CONDITION. EXTEND/REFINISH AL� FRAMES,
BASE, AND TRIM WHERE CUTTING HAS EXPOSED ANY UNFINISHED SURFACES. REPAIR ANY DAMAGE
TO EXISTING WORK AND RESTORE TO ORIGINAL CONDITION.
L CONTRACTORS SHA�� KEEP WORK AREAS AND ADJACENT PUBLIC CORRIDORS AND FACILITIES FREE
OF DEBRIS. MATERIALS STORED ON SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL
BE STORED IN A �OCATION APPROVED BY THE �ANDLORD.
M ALL P�UMBING ITEMS AND/OR EQUIPMENT ITEMS ARE TO BE COORDINATED AND VERIFIED WITH
INTERIOR ELEVATIONS PRIOR TO ROUGH-IN. ANY DISCREPANCIES SHALL BE COORDINATED WITH THE
DESIGNER.
N COORDINATED WITH OWNER AND FACI�ITY STAFF PROJECT PHASING TO MINIMIZE DISRUPTION OF
EXISTING FACI�ITY SERVICES. PHASING TO INCLUDE ASSURANCE FOR C�EAN AIRFLOW, WRITTEN
NOTIFICATION OF INTERRUPTIONS, AND COMMUNICATION AUTHORITY. CONTRACTOR, OWNER, AND
FACI�ITY STAFF TO PLAN FOR PROCEDURES ON THE EFFECTS OF NOISE AND VIBRATION ON HUMAN
HEALTH AND SAFETY. THE RENOVATED AREAS SHALL BE ISO�ATED FROM THE OCCUPIED AREAS
DURING ALL PHASES OF CONSTRUCTION USING AIRTIGHT BARRIERS, AND EXHAUST AIR FLOW SHALL
BE SUFFICIENT TO MAINTAIN NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE.
O SUBMIT THE REQUIRED NUMBER OF SUBMITTA�S FOR DESIGNER REVIEW AND APPROVAL PLUS ONE
EXTRA COPY FOR DESIGNERS RECORDS.
REFLECTED CEI�ING NOTES
A PROVIDE FIRE DAMPERS AT FIRE-RATED PARTITIONS AS REQUIRED PER APPLICAB�E BUILDING
CODES.
B CEILING IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS, AND ALL APP�ICABLE BUI�DING CODES.
C MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DUCTWORK, SUPPLY AND RETURN AIR
AND THERMOSTATS. COORDINATE ALL ELEMENTS OF THE NVAC SYSTEM TO PROVIDE A COMPLETELY
BA�ANCED AND EFFICIENT HEATING AND COOLING SYSTEM.
D HVAC THERMOSTAT CONTRO� FOR ALL ROOMS SHALL BE �OCATED WITHIN DEMISED SUITE. VERIFY
AND REWORK EXISTING DUCTWORK AND THERMOSTATS AS REQUIRED.
E MECHANICA� CONTRACTOR SHALL VERIFY WORKING CONDITION OF A�L EXITING THERMOSTATS, VAV
BOXES, EXHAUST FANS, AND ANY OTHER DEVICE DIRECTLY RELATED TO THE HVAC SYSTEM.
CONTRAGTOR TO NOTIFY ENGINEER/DESIGNER IMMEDIATELY UPON DISCOVERY OF DEFECTIVE
DEVICE.
ELECTRICAL NOTES
A THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT, AND
CONTRACTORS SERVICES NECESSARY TO COMPLETE INSTAL�ATION OF SYSTEMS REQUIRED IN FULL
CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONA�
AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE SYSTEM.
B ALL MATERIALS AND WORKMANSHIP SHALL MEET A�� APPLICABLE STATE AND �OCAL CODES,
ORDINANCES, UTI�ITY COMPANY REGULATIONS AND NATIONALLY ACCEPTED CODES AND STANDARDS.
THE ELECTRICAL CONTRACTOR WILL BEAR ALL COSTS ARISING IN CORRECTING ANY NON
COMPLIANCE WITH THE REQUIREMENTS OF APPLICAB�E CODES.
C CONTRACTOR TO SUPPLY AND INSTAL� ALL ELECTRICAL WIRING, INCLUDING RUNS FROM JUNCTION
BOX TO INDIVIDUA� WORKSTATION UNITS. CONTRACTOR TO SUPPLY P�ENUM RATED BOXES AND
PU��S AS REQUIRED TO ACCOMMODATE TENANT'S TE�EPHONE, DATA AND SECURITY DEVICES.
■
��� '
D� S I G N
200 s rangeline road
suite 213
carmel, indiana 46Q32
ph 317.573.2222
fx 317.573.2230
www.mitschdesign.com
�
�
o �Z
m U > I_
� � W �
W � �
�z�
oozQ�z
0
wWU���
U Q � � � ~
��J�K
� Z Q m J W
d
ZQ_
Uztti�
���a��
�o����
z � � � O a
¢=ow�x
(nF }m W W
z}�o�cn
wp°'�O�
oF��-cn�
viWaWp�
�� �- J W W
�ao¢ c�
�wz=�x
a�acnow
�
�
z
W
� �
U
J
o �
�r^ �
V! �
Z �p
O
U �
� W
� �
� Q
aw c~i�
DWG SCALE:
DRAWN BY:
CHECKED BY:
MD PROJECT #
�� � � � � �
AS NOTED
JS / ZH
KD
16078
aa a� o a a
�
, ,
DENTAL
TANKS
123
3'-74"
M
N
�
C�
C.
3'-102"
STAFF
�OUNGE
122
4
5
`o'a
�
1
124
9'-44„
07
I.T. CLOSET
MECNAN.
124
s� � �
�A � \
/
� �aa �� 119
� 118 0 �
� � )
�� i
_ _ ,� � • �.%'�-1 1 ` ' � �����
I
�' � �
i ` %�
i � � �
N � � �� �� \
� i ,' RESrtROOM �� �i '����-
K 1��17 �' i
�� , � 117
�� � �
-� �• — �
�� �i i
� � �'
��
116
PRIVATE
OFFICE
116
: :
STORAGE
119
V C � -
�% o
� �,
�, TREATMENT
120
os o2 �
CORRIDOR
121
11'-6"
/ c� 9'-7°
�
6'-1" - ................... —�--------------------------------------10'-5" ------------------- -�— 4'-4" —I
STERILIZATION
112
12'-6"
�
BUSINESS
OFFICE
103
IMAGE
_ ALCOVE
�? 106
06 �
�_
�
CONSULT
104
104 CORRIDOR
102
7'-2"
4'-1 �,�
I-. 4�_p�� —
CORRIDOR
107
3'-0" -- 3'-92„ � 6'-12.� 4'-0° -� 2'-6,� �,,,,— 3,_3�3,_�„ � ,�,,,,- 3,_�„ �� 3,_g�,. _ 6'-12�� - 4'-0,� _ .,� 2�_6° -��:� g�_p,� �,,, ,,,� g,_5�„ � �,_��., _
� //, �A TYP.
/
-- - 6'-2" - - - �
/'
� 1'-8" � �--�- T-8" �_•-- �. -.._� q �_g�� �..-
����, 1� /��� /i ✓/�/,,
o / o REC03ERY � / � o / o
N �_ � p � _ � �' N �� N
/
r 03 02 �; 03 02 � 03 02 d- j �- 03 02 /; � 03 02 �, �
� ' $11 �' � ✓'
, ,� i�i � �� -- %' � g, g,� - %i
1� , �1 �,, � 1
► �
:-
CV
� RECEPTION =
� 101 c
r .,,�. c
4'-3" i-{
4
IA
� � `\
, � � �
� � �
�' � �
�� / � �V A
105 �� �� RESTROOM�� �i
' ` 105 N i
� � \\ ��
� �
�� �
�I � � � ��
i' - - } = i
21'-2"
�
�
10
M�Q
— 9 -6 —
TREATMENT
115
— 9 -6 —
TREATMENT
114
6'-10"
CONSTRUCTION PLAN
.. . . . . .
SCA�E: 1/4"=1'-0"
�
�
TRUE
NORTH
�
: �
TREATMENT
110
9'-6"
TREATMENT
109
m m',
_ 9,_6„
TREATMENT
108
2�-6,�
CONSTRUCTION �EGEND
� EXISTING WALL OR ITEM TO REMAIN
— NEW F�OOR TO CEI�ING PARTITION (INSULATED)
REFER TO 1/IA001
� NEW F�OOR TO DECK PARTITION (INSULATED)
REFER TO 2lIA001
NEW PARTIAL HEIGHT WAL�
REFER TO 3/IA001
� �,� � NEW 1 HR FIRE PARTITION (INSULATED WITH SOUND DEADENING BARRIER)
REFER TO 4/IA001
GENERA� CONSTRUCTION NOTES
A PREPARE ALL EXISTING WALLS AND FLOORS TO RECEIVE NEW FINISHES. PATCH AND REPAIR AS
REQUIRED.
B PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WA�L MOUNTED
EQUIPMENT.
C REFER TO LEGENDS AND SCHEDU�ES ON IA001 FOR DOOR TYPES AND WALL DETAI�S.
� COORDINATE COUNTERTOP GROMMET LOCATIONS WITH OWNER PRIOR TO DRILLING.
0 CONSTRUCTION KEYNOTES
01 PROVIDE GARBAGE DISPOSA� WITH SWITCH ABOVE COUNTER.
02 SEE EQUIPMENT PROVIDER'S DRAWINGS FOR GAS FEED �INES IN THIS �OCATION.; COORDINATE
EXACT LOCATION IN FIELD WITH EQUIPMENT PROVIDER.
03 SEE EQUIPMENT PROVIDER'S DRAWINGS FOR WATERlSUCTION W FLOOR IN THIS LOCATION;
COORDINATE EXACT LOCATIONS W FIELD WITH EQUIPMENT PROVIDER.
04 EXISTING DRAIN; CONTRACTOR TO DRYWALL AROUND PIPE AND WRAP SHELF AROUND ACCORDINGLY.
05 PROVIDE A �AYER OF 4' PLYWOOD BEHIND GYPSUM BOARD ON WALL; SEE EQUIPMENT PROVIDER'S
DRAWINGS FOR MORE DETAIL.
06 PROVIDE NECESSARY B�OCKING FOR MOUNTED MONITOR AND FOLD DOWN KEYBOARD; SEE
EQUIPMENT PROVIDER'S DRAWINGS FOR MORE DETAI�.
07 DRAIN PROVIDED BY H.S.
08 G�ASS WALL SYSTEM TO BE PROVIDED BY CONTRACTOR AND EQUAL OR EQUIVALENT TO 10 2000 CRL
C�EAR GLASS WA�� OFFICE SYSTEM WITH 4" TOP AND BOTTOM RAI�S
09 2° TEMPERED CLEAR G�ASS TO BE PROVIDED BY CONTRACTOR WITH CLEAR COPOLYMER STRIPS
CONNECTING GLASS TO GLASS JOINT AND ABUTMENT TO WALUMUL�ION
10 DOOR TO BE FU�� GLASS WITH 12" LOOP HOLE FRONT TO BACK AND CONCEALED CLOSERS; PROVIDED
BY CONTRACTOR
11 ALIGN
� TOILET ACCESSORIES SCHEDULE
NO. ACCESSORY PRODUCT # REMARKS
1A ADA GRAB BARS B-6806-36 1-1/2" DIA STAINLESS STEEL GRAB BARS WITH SNAP F�ANGES
1 B B-6806-42 REFER TO 9&10/A601 FOR VERTICAL MOUNTING
1C B-6806-18 REQUIREMENTS.
2 TOILET PAPER B'4288 REFER TO 9/A601 FOR VERTICAL MOUNTING REQUIREMENTS.
3 PAPER TOWEL B-3944 RECESSED, MOUNT AT 40" A.F.F TO OPENING OF PAPER
DISPENSER/WASTE TOWELS.
RECEPTACLE
4 24"W x 36"H B-290 243 MOUNT BOTTOM OF MIRROR AT 40" A.F.F., CENTER OVER
MIRROR SINK. CHANNEL FRAME
5 COAT HOOK 8-233 MOUNT (1) INSIDE EACH INTERIOR RESTROOM DOOR. 48° A.F.F.
6 SOAP DISPENSER 8-4112 SURFACE-MOUNTED AT 40°A.F.F. TO CENTER PUSH BUTTON.
NOTE: ALL ACCESSORY PRODUCT NUMBERS REFERENCE BOBRICK BRAND ACCESSORIES
0 PLUMBING FIXTURE SCHEDU�E
NO. FIXTURE PRODUCT #
� AUTOMATIC DELTA 590LF-HGMHDF OR COMPARAB�E.
FAUCET
ADA COMPLIANT AMERICAN STANDARD WA�� MOUNTED SINK - SINGLE HOLE IN WHITE OR
2 RESTROOM COMPARABLE
SINK
ADA COMPLIANT AMERICAN STANDARD AFWALL 1.1-1.6 GPF UNIVERSAL F�USHOMETER TOILET, IN
3 WALL MOUNTED WHITE FINISH.
TOI LET
4 ADA COMPLIANT AMERICAN STANDARD MEMPHIS 25X20 KITCHEN SINK KIT 18SB.252211C.075
KITCHEN SINK
5 ADA COMPLIANT AMERICAN STANDARD HERITAGE SINGLE CONTROL GOOSENECK NAR SINK FAUCET
KITCHEN FAUCET 7100.241 H
■
��� '
D� S I G N
200 s rangeline road
suite 213
carmel, indiana 46032
ph 317.573.2222
fx 317.573.2230
www.mitschdesign.com
�
�
o �Z
?NU > 1-
o ��
w ��
�z�
oozQ�z
0
wWU���
U Q � � � ~
� � W J � �
zZom�a
zQ_
Uzui�
���a��
ao��cn�
�z�u-�Oa
¢ = O w � x
(nF }m W W
Z}�O�fn
wp°'�O�
oF��-cnrt
viWaWp�
�� �- J W W
�ao¢ c�
�wzx�x
a�a<now
�
�
Z
W
� �
U
J
o �
Hr^ �
v! �
Z m
O �
� W
C� Q
d=
� �
DWG SCALE:
DRAWN BY:
CHECKED BY:
MD PROJECT #
0
m m m m m m m
AS NOTED
JS / ZH
KD
16078
-- UNDERSIDE OF S�AB OR STRUCTURE ABOVE
i
�
ALL E�ECTRICAL EQUIPMENT IS
EXISTING. RELOCATION OF DUCTS
AND DIFFUSERS ON�Y
3 $" META� STUD
$" GYPSUM BOARD (3" ABOVE AND BELOW
CEILING HEIGHT)
CEILING AS SCHEDU�ED, REFER TO
REF�ECTED CEILING PLAN
13'-9" A.F.F.
GAP NEADER DETAIL (TYP
SCALE: 1'=1'-0"
00 0 0 0 0 0
REFLECTED CEILING PLAN
.. . . . . .
SCALE: 114"=1'-0"
!'
�
TRUE
NORTH
REF�ECTED CEILING LEGEND
_�� DENOTES NEW 2' X 2' ACOUSTICAL CEILING TI�E AND GRID; SEE IA701 FOR SPECIFICATION
� DENOTES LIGHT SWITCH
� DENOTES NEW EXHAUST FAN
� DENOTES EMERGENCY STROBE �IGHTS
� DENOTES EMERGENCY EXIT SIGN
EXTERIOR EMERGENCY LIGHT TO BE INSTALLED IF ONE IS NOT CURRENTLY IN PLACE; FIE�D
EM VERIFY.
�DENOTES NEW �ED CAN �IGHT
Y
DENOTES NEW PENDANT LIGHT (8' A.F.F.} FORNELLO 1 LED INTEGRATED BULB RING PENDANT
O 1 BY ELAN, SAND TEXTURED B�ACK (SKU #ELNL1224)
O• DENOTES NEW PENDANT LIGHT (72" A.F.F.) ROBERT ABBEY Z2183 SATURINA 3 �IGHT PENDANT
2 IN DEEP PATINA BRONZE
� 3 DENOTES NEW CHANDELIER (10' A.F.F.} ARTERIORS GEOFFREY MEDIUM CHANDE�IER #84174
U DENOTES NEW VANITY LIGHT
C'���� DENOTES NEW 2X4 �ED �IGHT
� DENOTES NEW DIFFUSERS
� DENOTES NEW AIR RETURNS
GENERA� REF�ECTED CEI�ING P�AN NOTES
A PAINT NEW GYPSUM BOARD BULKHEADS CEILING WHITE, UNLESS NOTED OTHERWISE.
B REMOVE EXISTING SWITCHES THAT ARE NOT RE-USED. REMOVE CONDUIT AND WIRING BACK TO
NEAREST BASE BUI�DING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH.
C THE GENERAL CONTRACTOR AND THE E�ECTRICAL CONTRACTOR SHA�L VERIFY A�L CEILING HEIGHTS
AND CEI�ING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, �IGHTING, AND OTHER
OBSTRUCTIONS TO ASSURE THE FINISHED CEI�ING NEIGHT INDICATED. ANY DISCREPANCY SHALL BE
BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK.
D CEILING HEIGHT THROUGHOUT THE SPACE IS TO BE 9'-0" A.F.F., UN�ESS NOTED OTHERWISE. CONFIRM
WITH DESIGNER AFTER DEMOLITION.
E EXISTING CEI�ING GRID AND ACOUSTICAL TILE TO REMAIN, UN�ESS NOTED OTHERWISE.
CONTRACTOR TO REMOVE AND REPLACE ANY EXISTING CEI�ING TILES AND CEILING GRID THAT IS
BROKEN, CHIPPED, OR PUNCTURED WITH NEW TO MATCH EXISTING.
F ALL NEW SWITCHES FOR �IGHTING SHALL BE LOCATED AS SHOWN ON P�ANS. MOUNT CENTER OF
SWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE.
G EXIT SIGNS, DOWN LIGHTS, SPRINKLER HEADS, ETC. SHALL BE CENTERED WITHIN CEILING TILE,
UN�ESS NOTED OTHERWISE.
H COLOR OF LIGHT SWITCH DEVICES AND COVERPLATE TO BE WHITE, UNLESS NOTED OTHERWISE.
� ALL MULTIPLE SWITCH �OCATIONS TO BE GROUPED TOGETHER AND LABE�ED WITH A SINGLE DEVICE
COVERPLATE.
J REFER TO ENGINEERING DOCUMENTS FOR INFORMATION, �OCATION AND SPECIFICATIONS ON EXIT
SIGNAGE, �IFE SAFETY SYSTEMS, 24 HOUR EMERGENCY LIGHTING, VENTI�ATION, HVAC SYSTEMS,
CIRCUITING OF LIGHTS AND THERMOSTAT �OCATION ETC.
K THERMOSTATS SHALL BE �OCATED DIRECTLY ABOVE OR ADJACENT TO LIGHT SWITCH. ALL
THERMOSTAT POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFORE
PLACEMENT.
� SUPPLY AND RETURN AIR GRILLES ARE TO BE FLUSH WITH NEW CEILING TILES AND ARE TO BE WHITE
IN CO�OR. REFER TO ENGINEERING DOCUMENTS FOR ADDITIONAL INFORMATION.
M ALL DIMENSIONS ARE TO THE CENTERLINE OF FIXTURE, UN�ESS NOTED OTHERWISE.
N IF REQUIRED, ALL CEI�ING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THE
DESIGNER PRIOR TO INSTAL�ATION.
� VERIFY ALL SPRINKLER HEAD LOCATIONS. NOTIFY DESIGNER IF ANY DISCREPANCIES OCCUR.
P COORDINATE COMMON AREA SWITCHING WITH OWNER PRIOR TO INSTA�LATION.
� REFLECTED CEILING PLAN KEYNOTES
01 PROVIDE BLOCKING ABOVE CEI�ING IN THIS LOCATION FOR CEILING MOUNTED OPERATIVE LIGHT.
CEILING GRID WI�� ADJUST ACCORDING TO FINAL OPERATIVE �IGHT SPECIFICATION. COORDINATE
WITH DESIGNER AND EQUIPMENT PROVIDER FOR FINA� PLACEMENT AND �AYOUT.
02 EXISTING DRAIN PIPE
03 3" STEEL TUBE PROVIDED AND INSTALLED BY CONTRACTOR FOR TELEVISION MOUNT; HEIGHT NEEDS
TO BE COORDINATED WITH H.S.; TELEVISION MOUNT PROVIDED BY H.S.
04 HIGH ! LOW EXHAUST VENT TO BE TERMINATED AT THE EXTERIOR OF THE BUI�DING
05 PROVIDE OCCUPANCY SENSOR SWITCHING IN THIS LOCATION.
■
��� '
D� S I G N
200 s rangeline road
suite 213
carmel, indiana 46032
ph 317.573.2222
fx 317.573.2230
www.mitschdesign.com
W
U
�
�
0
J
�
�
Z
W
0
�
�
o�
o Z
?N U > 1-
� � W �
W �, �
�z�
oozQ�z
0
wWU���
U Q � � � ~
��J�K
� Z Q m J W
a
ZQ_
Uzui�
���a��
aof=�cn�
z � � � O a
a=ow�x
(nF }m W W
Z t-�=fn
wp°'�O�
oF��-cnrt
viWaWp�
�� �- J W W
�ao¢ c�
�wz=�x
a�a<now
�
�
Z
W
� �
U
J
� �
H �
� �
z
m
� �
� W
� �
C' Q
f �
6� (J�
DWG SCALE:
DRAWN BY:
CHECKED BY:
MD PROJECT #
�
��
AS NOTED
JS / ZH
KD
16078
REFLECTED CEI�ING
PLAN (LOCATION ONLY)
0
0
�
,_ _ �,, 1,�,
, �. � � �
� � �
�
� � � �
� � � �
� , , > �,
� ' -' ' �
�, �
� � , �
�� , �
I �� , �
�� �
� �� ` �'GFI .
����
(
C
I€
�F I
+ 2,�
�
m
���
m
�
m
m
ELECTRICAL PLAN
„, , , , ,
SCALE: 114"=1'-0"
m
�
�
TRUE
NORTH
`�j
.��
�
" \�c l
, ^
�' � �� �
� � � �
, , � \
� �' �� �
�< � �
� � `� i
� � �i
� �� �
� � �i
� �,
` ��
� �FI ',
,�
�� ` <
,�
�s
�
�
AY
1• I
�
m'
�
TV
+##
110V STANDARD DUPLEX RECEPTACLE
110V STANDARD QUAD RECEPTAC�E
DEDICATED DUPLEX RECEPTACLE
PROVIDE FLOOR BOX; COORDINATE �OCATION AND SIZE REQUIREMENTS FOR A��
POWER, SUCTION, AND WATER NEEDS IN THIS BOX; SEPARATE PER CODE.
VOICE/DATA OUTLET
DENOTES GROUND FAULT INTERRUPTER
DENOTES ITEM FOR TENANT PROVIDED TV
DENOTES CENTERLINE MOUNTING HEIGHT OF OUT�ET/RECEPTACLE
GENERAL E�ECTRICAL/DATA NOTES
q THE ELECTRICA� CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE
CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION.
g ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS
AS INDICATED ON DRAWINGS OR AS REQUESTED BY TENANT. VERIFY ACTUAL REQUIREMENTS WITH
DESIGNER PRIOR TO INSTALLATION.
C ELECTRICAL CONTRAGTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT TE�EPHONE/DATA
�OCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS (MATERIA� AND �ABOR)
TO BE PROVIDED BY THE TENANT UNLESS OTHERWISE NOTED.
p ALL SECURITY SYSTEMS TO BE PROVIDED BY TENANT UN�ESS NOTED OTHERWISE.
E ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICA� AND LIGHTING REQUIREMENTS FOR
MI�LWORK AND CABINETRY WITH CONTRACTOR AS NECESSARY.
F ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED VERTICALLY AT 18" A.F.F. TO CENTERLINE OF
OUTLET, UN�ESS OTHERWISE NOTED.
G SWITCH P�ATES, MONUMENTS, AND E�ECTRICAL COVER PLATES SHA�� BE BUILDING STANDARD
WHITE.
H ALL DIMENSIONS SHOWN ARE TO CENTERLINE OF OUTLETS OR GROUP OF OUTLETS, UNLESS
OTNERWISE NOTED.
1 DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRED TO MINIMIZE
SOUND TRANSMISSION.
J ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE GANGED, THEY SHALL
BE INSTA��ED WITH A MINIMUM DISTANCE BETWEEN UNITS.
K CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETY DEVICES AS REQUIRED BY STATE AND LOCA�
BUI�DING CODES.
� ELECTRICAL CONTRACTOR TO VERIFY WORKING CONDITION OF A�� SWITCHES, LIGHT FIXTURES,
BALLASTS, EXIT, AND EMERGENCY LIGHTS AND OUT�ETS, REP�ACE IF NECESSARY.
M DO NOT SCALE DRAWINGS; ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS FIELD
CONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST WITH NEW CONSTRUCTION MUST
BE REVIEWED BY DESIGNER PRIOR TO CONSTRUCTION OF WORK. DO NOT CIRCUMVENT DIMENSIONS
BY ATTACHING RECEPTAGLES TO NEAREST STUD.
N THESE E�ECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSULT WITH ELECTRICA� ENGINEER
FOR FURTHER TECHNICA� INFORMATION.
o ELECTRICAL/DATA OUTLET LOCATIONS TO BE VERIFIED WITH TENANT PRIOR TO ROUGH-IN. ALL
LOCATIONS TO BE VERIFIED WITH FURNITURE PLACEMENT.
P SYSTEMS FURNITURE TO BE DRAWN ON F�OOR PRIOR TO P�ACEMENT OF F�OOR CORE AND
JUNCTION BOXES. DESIGNER TO APPROVE �OCATIONS PRIOR TO CORING/PLACEMENT.
Q ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONNECTING DEALER PROVIDED FURNITURE
SYSTEMS POWER IN-FEED TO BUILDING J-BOX WHERE INDICATED ON P�AN.
R ALL ELECTRICAL EQUIPMENT PROVIDED BY OTHERS
� ELECTRICA�/DATA KEYNOTES
01 PROVIDE RECESSED FLOOR CORE TO BE CONCEA�ED UNDER MEDICA� CHAIR. CONFIRM EXACT
LOCATION WITH OWNER, DESIGNER, AND EQUIPMENT PROVIDER.
02 COORDINATE FINAL ELECTRICAL LOCATION WITH DESIGNER, OWNER AND EQUIPMENT PROVIDER.
03 PROVIDE GARBAGE DISPOSAL WITH SWITCH ABOVE COUNTER TOP AT THIS �OCATION.
04 COORDINATE ELECTRICAL WITH MICROWAVE �OCATION.
05 COORDINATE E�ECTRICAL WITH UNDER COUNTER REFRIGERATOR LOCATION.
06 TV AND MOUNT TO BE PROVIDED BY OWNER.
07 TANK ALARM, COORDINATE LOCATION AND VOLTAGE REQUIREMENTS WITH EQUIPMENT PROVIDER.
08 PROVIDE 3" GROMMET AND CAP IN THIS LOCATION
09 ELECTRICAL TRACK MOUNTED TO CEILING PROVIDED BY H.S.; CONTRACTOR TO PROVIDE NECESSARY
BLOCKING
10 OXYGEN OUTLET PROVIDED BY H.S.
11 COORDINATE SERVER OUTLETS AND REQUIREMENTS WITH OWNER
■
��� '
D� S I G N
200 s rangeline road
suite 213
carmel, indiana 46032
ph 317.573.2222
fx 317.573.2230
www.mitschdesign.com
W
U
�
�
0
J
�
Z
W
�
�
�
o �Z
mU > 1-
o ��
w ��
�zr
oOZQ�z
0
wWU���
U Q � � � ~
��J�K
� Z Q m J W
d
ZQ_
Uztti�
���a��
do����
z � � � O a
a=ow�x
(nF }m W W
�}���W
wp°'�O�
oF��-cn�
viWaWp�
�� f- J W W
�ao¢ c�
�wz=�x
a�a<now
�
�
z
W
� �
U
J
� �
�r^ �
Vd �
Z m
�
U c�j)
� W
� �
C' Q
rn in
DWG SCALE:
DRAWN BY:
CHECKED BY:
MD PROJECT #
�
�
e e e e e e e
AS NOTED
JS / ZH
KD
16078
ee e� o e e
ELECTRICA�/DATA
�LAN (LOCATION ONLY)
� '
• ': ' � ' �
� �
I �'-$" �"I
CEI�ING
LINE
PL-1 CABINETS WITH
ADJUSTABLE SHELVES
SS-2 COUNTERTOP
WITH 4" BACKSP�ASH
SS-2
DRAWERS
PL-1 CABINET WITH
ADJUSTABLE SHE�VES
FLOOR LINE
OWNER
PROVIDED
REFRIGERATOR
�-- 3'-2„
m
1'-7"
1'-7" --)
CEILING
LINE
-I- ADJUSTABLE
o SHELVES
�
�PL-1 UPPER
CABINETS
� PL-2
�
�PLASTIC LAMINATE
COUNTER (PL-2)
WITH 4" BACKPLASH
OWNER PROVIDED
DISHWASHER
— PL-1 CABINET WITH
� ADJUSTABLE
SHELVES
FLOOR LINE
� � �
BREAKROOM
.
mmm m m m m
SCA�E: 112"=1'-0"
HAND WASH STATION- TYPICAL
00 0 0 0 0 0
SCA�E: 1/2"=1'-0"
Ci�
FF
ADJUS
SH
FR�
�
RETl1RN RECEPTION ELEVATION
ee e e e e e
SCA�E: 112"=1'-0"
EXIS�
CO�
SIDE RECEPTION ELEVATION RECEPTION ELEVATION
... ... . aaa a a a a
SCALE: 1l2"=1'-0° SCA�E: 1/2"=1'-0"
� � � � , � ,
, �
�DROP
CEILING
LINE
� K���F'I IUN �L�VAI IUI�
�� � � � � �
SCA�E: 112"=1'-0"
/� • i
SS-1
PARTIAL
HT. WA�L
CLAD IN
PL-1
D E S I t
200 s rangeline rc
suite 213
carmel, indiana 4
ph 317.573.2222
fx 317.573.2230
•
.
•
�N
�ad
3032
�
�
�
o�
o Z
mU >1-
�� w�
�zi- cn�
o�z��z
oo�a�,o
wWU��W
U a � � � ~
� � W J � �
ZZ�6] J(JJ
cn�=�aa
���ah�
ao�cnrn�
�z��-�Oa
¢=ow�x
�F�mww
z ro=cn
wp°'�O�
o���-�n�
aiWaWp�
w�=>rnF-
�ao¢WCWi
� W Z S� X
Qd'Q(n� W
�
F
Z
W
� �
U
J
� �
�p� �
VJ �
Z
m
O �
� W
d� Q
� �
6� C!�
DWG SCALE:
DRAWN BY:
CHECKED BY:
MD PROJECT #
�
4 4 4 4 4 4 4
AS NOTED
JS / ZH
KD
16078
aa a a a a a
_EVATIONS
� � ADJUSTAB�E SHELF II �
II II II II
II (I II (I ADJUSTAB�E SHELF
�� (�
�� (�
(I (I � WALL CABINET M
� II II
� II (I II II WA�L CABINET
�� �� �� ��
� � �� ��
�� (�
� � SOLID SURFACE
1'-0" --) COUNTERTOP
SS-1 COUNTERTOP
�
— 1'-0" —�
PL-2 COUNTERTOP
W/4" BACKSPLASH ao DOOR PULLS DOOR PUL�S
i� ��
�� �� ADJUSTAB�E SHELF
I �� ��
�� ��
I � � �- �� ��
° ° F�USH DOOR WITH CONCEALED HINGES
�� ��
� �� ��
OPEN FOR I i W
DISHWASHER I � �� � � o
M ii ii
I N II II
q � i� �i DRAWERS �� ��
� ii ii
� � ° ° PL-1 BASE CABINET
I u u
,,, L J .____�_
BASE BASE BASE
2'-0" � 2'-0° 2 -0
BREAKR00�1 SECTOIN RETURN RECEPTION SECTION BEVERAGE STATION SECTION
O O O O O O O �� � � � � � O 4 4 4 4 4 4
SCALE: 314"=1'-0" SCALE: 314"=1'-0" SCALE: 314"=1'-0"
�I �I ADJUSTABLE SHELF � �
I� I� I� ��
II II II II ADJUSTAB�E SHELF
I� ��
I) ��
II II WALL CABINET M
� I� I�
� II II I) I) WA�L CABINET
I� I� I� ��
� � II II
II II
� �-o�� � �
� 1'-0" ----� SS-1 TRANSACTION
TOP & FACE
PL-2 COUNTERTOP SS-1 COUNTERTOP -� 1'-6"
W/4"BACKSP�ASH -
�
I I DOOR PULLS DOOR PULLS -- - 2'-0" --
PLASTIC LAMINATE COUNTER TOP
`------'
� ADJUSTABLE SHELF
FALSEFRONT ° °
-
ii u � � �
ii ii � i �i 3 5/8" META� STUDS, 16" O.C. WITH 5/8"
ii ii
`� ° ° FLUSH DOOR WITH CONCEALED "' i �i GYPSUM BOARD BOTH SIDES
o `V ii ii HINGES _ _ 1 i �� SUPPORT BLOCKING AS
- -, -, �--------------� REQUIRED
� BASE CABINET u u "' "' i i �i PL-1
ii ii PLASTIC LAMINATE BASE CABINET
i i)
� � � i i
� �
�'
BASE BASE �--- ------ --�
F�OOR LINE
1'-11" - 2'-0" -
BREAKROOM SECTION RETURN RECEPTION SECTION RECEPTION SECTION
�� � � � � � �� � � � � � .. . . . . .
SCALE: 314"=1'-0" SCALE: 3l4"=1'-0" SCALE: 314"=1'-0"
� �
II II
� � ADJUSTABLE SHELF � � ADJUSTABLE SHELF
II II II II ADJUSTABLE SHELF
�I �I I� I� I� I�
�
�
II II WALL CABINET II II WAL� CABINET II II
�i II II �i II II II II
M II II m II II
�I �I I� I� I� I�
II II SOLID SURFACE � � SOLID SURFACE
COUNTERTOP W/4° COUNTERTOP W/4" u u
BACKSPLASH BACKSP�ASH
1'-0" --� 1'-0" �-I � SS-1 COUNTERTOP SS-1 TRANSACTION
2'-6" '- TOP & FACE
a�
� � � � �_6��
� DRAWER
DOOR PU�LS
� � � DOOR PULLS PLASTIC LAMINATE COUNTER TOP
i � � SUPPORT BLOCKING AS
L------------- ADJUSTABLE SHELF `------' ( REQUIRED
II (I FALSE FRONT ( 3 5/8" METAL STUDS, 16" O.C. WITH 5/8"
I GYPSUM BOARD BOTH SIDES
ii ii o OPEN FOR �
�, REFRIGERATOR � _
u ii � � �
� �� �� F�USH DOOR WITH CONCEALED � ( "' "' PL-1
M ii i� HINGES � (
u ii
� � (
� F�OOR LINE
BASE BASE BASE
1'-11 ° - 2'-0" ----� 2'-0" -
�AB SECTION BREAKROOM SECTION BEVERAGE STATION SECTION RECEPTION SECTION
... .... ��� ��� � o00 0 0 0 0 000 0 0 0 0
SCALE: 314"=1'-0" SCALE: 314"=1'-0" SCALE: 3l4"=1'-0" SCALE: 314"=1'-0"
■
��� '
D� S I G N
200 s rangeline road
suite 213
carmel, indiana 46032
ph 317.573.2222
fx 317.573.2230
www.mitschdesign.com
W
U
�
�
0
J
�
�
Z
W
0
�
�
o�
o Z
?N U > 1-
� � W �
W � �
KZI-
oOZQ�Z
0
wWU���
U Q � � � ~
��J�K
� Z Q m J W
a
ZQ_
Uzui�
���a��
aof=�cn�
z � � � O a
a=ow�x
(nF }m W W
z}�o�v�
wp°'�O�
oF��-cnrt
viWaWp�
�� �- J W W
�ao¢ c�
�wzx�x
a�a<now
�
�
z
W
� �
U
J
� �
Hr^ �
V! �
z
m
� �
� W
� Q
rn in
DWG SCALE:
DRAWN BY:
CHECKED BY:
MD PROJECT #
�
��
AS NOTED
JS / ZH
KD
16078
SECTIONS/DETAILS
♦ J
� 1
ROOM SCHEDULE
NUMBER NAME WA�L FINISH
100 WAITING WC-1, PT-3
101 RECEPTION WC-1, WC-2
102 CORRIDOR PT-1, PT-3
103 BUSINESS OFFICE PT-1, PT-5
104 CONSU�T PT-1, WG3
105 RESTROOM PT-5
106 IMAGE ALCOVE PT-1
107 CORRIDOR PT-1, PT-4
108 TREATMENT ROOM PT-1, PT-4, WT-1
109 TREATMENT ROOM PT-1, PT-4, WT-1
110 TREATMENT ROOM PT-1, PT-4, WT-1
111 TREATMENT ROOM PT-1, PT-4, WT-1
112 STERI�IZATION PT-1, WT-1
113 RECOVERY ROOM PT-1, PT-4
114 TREATMENT ROOM PT-1, PT-4, WT-1
115 TREATMENT ROOM PT-1, PT-4, WT-1
116 PRIVATE OFFICE PT-1, WC-4
117 RESTROOM PT-5
118 �AB PT-1
119 STORAGE PT-1
120 TREATMENT ROOM PT-1, PT-4
121 CORRIDOR PT-1, PT-3
122 STAFF LOUNGE PT-5
123 DENTAL TANKS PT-1
124 I. T. STORAGE & MECHN. PT-1
125 VESTIBULE -
EI
FLOOR FINISH
LVT-1
LVT-1
�VT-1
CPT-1
CPT-1
�VT-1
LVT-1
LVT-1
LVT-1
LVT-1
LVT-1
LVT-1
LVT-1
LVT-1
LVT-1
LVT-1
CPT-1
LVT-1
VCT-1
VCT-1
LVT-1
LVT-1
VCT-1
VCT-1
VCT-1
CPT-2
BASE FINISH
VB-1
VB-1
VB-1
VB-1
VB-1
VB-1
vg-�
VB-1
VB-1
VB-1
vg-�
vg-�
VB-1
VB-1
VB-1
VB-1
VB-1
VB-1
VB-1
VB-1
VB-1
VB-1
VB-1
VB-1
VB-1
CEILING FINISH
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
ACT-1
SS-1
SS-1
SS-1
SS-2
SS-2
ss-2
ss-2
SS-2
SS-2
SS-2
SS-2
SS-2
SS-2
CASEWORK
PL-1
PL-1, SS-1
PL-1
PL-1
PL-1
PL-1
PL-1
PL-1
PL-1
�
FINISN LEGEND
CODE MATERIAL MANUFACTURER
FLOOR MATERIAL
CPT-1 CARPET TANDUS CENTIVA
CPT-2 CARPET MOHAWK
LVT-1 LUXURY VINYL TILE MOHAWK
VCT-1 VINYL COMPOSITION TILE ARMSTRONG
WALL MATERIAL
PT-1 PAINT SHERWIN WIL�IAMS
PT-2 PAINT SHERWIN WIL�IAMS
PT-3 PAINT SHERWIN WIL�IAMS
PT-4 PAINT SHERWIN WIL�IAMS
PT-5 PAINT SHERWIN WI��IAMS
WC-1 WA�� COVERING MDC WALL
WC-2 WA�� COVERING DL COUCH
WC-3 WA�� COVERING MDC WALL
WC-4 WA�� COVERING MDC WALL
WT-1 WA�� TILE DALTILE
SURFACE MATERIA�
P�-1 PLASTIC LAMINATE ARBORITE
P�-2 PLASTIC LAMINATE ARBORITE
SS-1 QUARTZ CAMBRIA
SS-2 SOLID SURFACE CORIAN
CEILING MATERIAL
ACT-1 ACOUSTICA� CEILING TI�E ARMSTRONG
OTHER MATERIA�S
VB-1 VINY� BASE JOHNSONITE
CG-1 METAL CORNER GUARD SCHLUTER
� FINISH PLAN AND SCNEDULE
00 0 0 0 0 0
SCALE: NOT TO SCALE
�
�
TRUE
NORTH
PATTERN / STYLE I COLOR
EVOKE SMOKE EMBERS
TUFF STUFF II/ FIRST STEP II OBSEDIAN
TRENTA MINK
IMPERIAL TEXTURE SHELTER WHITE
SAT I N
SEMI-GLOSS
SAT I N
SAT I N
SAT I N
CORONADO
PRISM
QUILTED
HAVANA
CLIO MOSAICS
STANDARD
GREY XABIA
WATERSTONE CO�LECTION
PRIVATE COLLECTION
OPTIMA SQUARE LAY-IN
4" STANDARD BASE
1/4"
� � � ll�i�
A00001/31902 24" X 24" TILES
QL315/989 24" X 24" WA�K OFF CARPET TILE
C0051/858 7.25" X 48" P�ANK
51836 STANDARD EXCELON; 12 X 12 TILE
HIGH REFLECTIVE WHITE 7757 GENERAL WA�L CO�OR
B�ACK MAGIC 6991 TRIM AND ANY EXPOSED CEILING
ROYCROFT PEWTER 2848 ACCENT
RAINSTORM 6230 ACCENT
INTERESTING AQUA 6220 ACCENT
MINESHAFT 3614CR14526 54" WIDE, RANDOM MATCH; CONTACT BRENDA AT 317.383.6995
331 A153-331 52" WIDE, STRAIGHT MATCH; CONTACT MISTY AT 317.557.5347
BAY TFC1115 54" WIDE; STRAIGHT MATCH; CONTACT BRENDA AT 317.383.6995
ONYX MHA5910/4526 54" WIDE, RANDOM MATCH; CONTACT BRENDA AT 317.383.6995
LUNA CL13 12 X 12 MESH SHEETS; CONTACT CHRIS AT 317.727.0230
GROUT: CUSTOM BUI�DING PRODUCTS. SNOW WHITE #11
RUCHED JUTE
XABIA GRIS.
BELLINGHAM
SAND STORM
WHITE
BURNT UMBER
STAINLESS STEEL
P-364-SR N/A
P-317-CA N/A
N/A RECEPTION DESK
N/A NlA
1900 24" X 24" X 15/16; NRC: .75 / CAC: 35;
63 ' -
x END WT-1 WITH CORNER GUARD AT SINK STATIONS
� ♦ � ♦ �
A ALL WALLS TO BE PAINTED PT-1, UNLESS NOTED OTHER WISE.
B A�� DOOR FRAMES TO BE PAINTED PT-2 IN A SEMI-G�OSS FINISH UN�ESS NOTED OTHERWISE.
C PROCEEDING WITH THE INSTALLATION OF FINISHES WIL� BE CONSTRUED THAT THE INSTALLER
ANDIOR FINISHER HAS INSPECTED AND ACCEPTED THE SUBSTRATE FOR RECEIVING THE WORK. NO
CHANGE ORDER WILL BE ISSUED TO RECTIFY CONCEALED, UNKNOWN CONDITIONS OR
UNSATISFACTORY SUBSTRATE ONCE THE FINISH WORK HAS PROCEEDED.
D USE MANUFACTURER'S RECOMMENDED INSTALLATION METHODS AND MATERIALS FOR ALL FINISHES.
E F�OORING CONTRACTOR TO PROVIDE SEAMING DIAGRAM FOR CARPET �AYOUT FOR DESIGNER'S
APPROVAL PRIOR TO INSTA�LATION.
F CONTRACTOR TO IMMEDIATELY NOTIFY DESIGNER IF A SPECIFIED FINISH ITEM BECOMES
UNAVAILABLE.
G CONTRACTOR TO SUBMIT SHOP DRAWINGS SHOWING TRANSITION LOCATIONS FOR DESIGNER'S
APPROVA�.
H PAINT ALL GRILLES, FIRE EXTINGUISHER CABINETS, ETC., TO MATCH SURFACE ON WHICH THEY
occuR.
1 F�OORING CONTRACTOR TO �EVEL EXISTING FLOOR AS REQUIRED TO ACCEPT NEW FLOORING
MATERIAL. USE SUB-F�OR REDUCER STRIPS TO LEVEL CARPET OF UNEQUAL HEIGHTS.
J USE RUBBER TRANSITIONS STRIPS WHERE VCT MEETS CARPET. (CONTRACTOR TO SUBMIT COLOR
SAMPLES TO DESIGNER FOR APPROVAL.) CENTER TRANSITION STRIP UNDER CENTERLINE OF DOOR
OR CENTERLINE OF OPENING, WHICHEVER APPLIES. TRANSITIONS TO MATCH VB-1.
K ALL LIMESTONE/MARB�E TILE AND SLAB TO BE CLEANED AND/OR SEALED PER STONE SUPP�IER'S
RECOMMENDATIONS.
L STONE FLOORING CONTRACTOR TO PROVIDE �AYOUT DIAGRAM FOR DESIGNER'S APPROVA� PRIOR
TO INSTALLATION.
M CENTER ALL APPLICABLE CARPET LWES UNDER CENTER�INE OF DOOR (WHILE W CLOSED POSITION).
ABBREVIATIONS
DECK OPEN TO DECK
ETR EXISTING TO REMAIN
NIC NOT IN CONTRACT
ME MATCH TO EXISTING
SC SEALED CONCRETE
TBD TO BE DETERMINED BY DESIGNER
UNO UNLESS NOTED OTHERWISE
OFOI OWNER FURNISHED, OWNER INSTAL�ED
0 FINISH KEYNOTES
1� SEE A601 SHEET FOR WT-1 APPLICATION ON THIS WA�L.
�2 BACKSPLASH TO BE WT-1.
A AL� WOODWORK/MIL�WORK SHALL CONFORM TO THE QUALITY STANDARDS OF ARCHITECTURAL
WOODWORK INSTITUTE (AWI) PREMIUM GRADE. FABRICATOR SHALL BE FAMILIAR WITH AWI
STANDARDS.
B FABRICATE WOODWORK/MI��WORK ITEMS TO ACTUA� FIELD DIMENSIONS. CONTRACTOR(S) SHA�L
SUBMIT, FOR DESIGNER'S APPROVAL, SHOP DRAWINGS, SAMPLES, OR MANUFACTURER'S LITERATURE
FOR ALL ITEMS. SHOP DRAWINGS SHALL SHOW SUFFICIENT DETAIL TO DETERMINE COMPLIANCE
WITH QUA�ITY STANDARDS AND DESIGN INTENT.
C PROVIDE ALL NECESSARY FURRING AND GROUNDS FOR WOODWORK ANd FINISH ITEMS.
COORDINATE LOCATION OF BLOCKING WITHIN PARTITIONS FOR ITEMS TO BE SECURED TO SURFACE.
ALL FASTENERS SNA�� BE CONCEALED.
D ALL MI��WORK HARDWARE TO BE HAFELE 101.20.72 HANDLE PUL�, STAINLESS STEEL, UNLESS NOTED
OTHERWISE.
■
��� '
D� S I G N
200 s rangeline road
suite 213
carmel, indiana 46032
ph 317.573.2222
fx 317.573.2230
www.mitschdesign.com
�
�
o�
o Z
?N U > 1-
� � W �
W ��
�z�
oozQ�z
0
wWU���
U Q � � � ~
��J�K
� Z Q m J W
a
ZQ_
Uzui�
���a��
aof=�cn�
�z�u-�Oa
¢=ow�x
(nF }m W W
Z t-�=fn
wp°'�O�
o��LL��
viWaWp�
�� �- J W W
�ao¢ c�
�wz=�x
a�a<now
�
�
z
W
� �
U
J
� �
� �
� �
z
m
o �
� W
� �
C' Q
f �
O� U�
DWG SCALE:
DRAWN BY:
CHECKED BY:
MD PROJECT #
0
mm m m m m m
AS NOTED
JS / ZH
KD
16078
FINISN P�AN &
SCHEDULE