Loading...
HomeMy WebLinkAbout16120019 Site PlanGar. FFE = 907.0 1 st Flr FFE = 908.3 Bsmt FFE = 899.1 Drive Slope = 2.9% � 12' ALLEY 60.00, 12' ALLEY 05 ESMT APRON 18' CONC DRIVE � } i 06.5 I �9.0' � O O � M a M f � � o�o.00� 06.0 F � � o a 11.0' �°z.00�� � TBM Note: � 24.00' � � � � 0 � TWO CAR a � GAR g (UNEXC) " OSPIT P PROPSED RESIDENCE BSMT 00 �o Q � a 32.0( 07.5 I �' � 20' BTL + > 15'DU&SE 2 � 2' NAE 4 �Q-�43.00 5' WALK � O O � � � I n � O O, 04.6 26. SAN MH 401 ti�T TG-904.40 SAN SEWER 04.1 16.0' TBM — — 03.8 2' CURB � GLEBE STREET � ' (34.5' BC-BC)_ �� r.i iRa W WATER LINE The lowest elevation to have gravity sanitary sewer service must be more than one (1) foot above the lowest top of casting elevation of either the first upstream or downstream manhole on the main line sewer to which the connection is made. Flood Hazard Note: Lot Number 559 lies within Flood Hazard Zone "X" per the scaled location on the Flood Insurance Rate Maps for Hamilton County, Indiana (Community Panel 18057CO205G, dated November 19, 2014). Note: This document has been prepared for the benefit of the parties indicated hereon, for the express use of obtaining a residential building permit. This document has been prepared and based upon the construction documents, record drawings, and additional information prepared for this development by others. This document is not based upon a field survey and Coor Consulting does not warrant the accuracy or completeness of this information. 0 c�o��a0�o�g � D�a�c� �c�r��oc�c��g C� O C� [� O G' �� 0 O Cr� 303 WEST MAIN STREET KNIGHTSTOWN. INDIANA (888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692 DATE: 10/26/16 JOB #2016-106 REVISIONS: Note: Minimum Front Yard - 20' Minimum Side Yard - 5' or 8% Minimum SY Aggregate - 15' or 81 % Minimum Rear Yard - 20' LOT # 559 ±8, 855 S F NO PAD PER PLAN SAN MH D425 TC=902.74 Note: Q��ac,�c�c� �c����o ��� Note: �]or��[� _ �30' Contractor should verify sump pit location with Field Manager. XX.X = Proposed Grade Per Plans � = Drainage Flow — SF — = Proposed Silt Fence Contractor should verify site specific information depicted hereon with the approved construction plans for this development in regards to sidewalk and handicap ramp placement, widths, and construction. Contractor should verify site specific information in regards to erosion control placement and materials. Also, Contractor should reference Architectural plans for foundation orientation and dimensions. Unless otherwise stated hereon, no information pertaining to but not The contractor/owner should verify existing conditions prior to construction. Any varying field conditions or any discrepancy with the information contained hereon should be immediately reported to COOR Consulting & Land Services, Corp.; failure to do so would result in the contractor/owners assumption of liability. Note: Unless otherwise stated hereon, no information pertaining to but not limited to, fluctuating water tables elevations, soil types, and conditions within the building areas of this development have been provided and\or referenced on said documents. With the excavation of the proposed structure foundations, certain care and observations should be made in regard to such conditions as soil types and fluctuating water tables. During the excavation process should any unsuitable soils or ground water be witnessed, the builder shall be immediately notified for further examination and consultation. At the builders discretion, additional construction techniques may be necessary to alleviate future problems. VILLAGE OF PLOT PLAN WESTCLAY Prepared For: SECTION 8501 P.C. 2, SLIDE 642 INSTR #200500050871 EVAN J. DENNIS "PHILLIPS HOME" LOT # 559 2396 GLEBE STREET CARMEL, IN 46032