HomeMy WebLinkAbout16120019 Site PlanGar. FFE = 907.0
1 st Flr FFE = 908.3
Bsmt FFE = 899.1
Drive Slope = 2.9%
� 12' ALLEY 60.00,
12' ALLEY 05
ESMT APRON
18'
CONC
DRIVE
�
} i
06.5 I
�9.0'
�
O O
�
M a
M f
�
� o�o.00�
06.0 F � �
o a
11.0' �°z.00�� �
TBM
Note:
�
24.00' � �
� �
0
� TWO CAR a
� GAR g
(UNEXC) "
OSPIT P
PROPSED
RESIDENCE
BSMT
00
�o
Q �
a
32.0(
07.5 I
�' � 20' BTL +
> 15'DU&SE 2
� 2' NAE
4 �Q-�43.00
5' WALK
�
O
O
�
�
� I
n �
O O,
04.6
26. SAN MH 401
ti�T TG-904.40
SAN SEWER
04.1
16.0'
TBM
— — 03.8
2' CURB
�
GLEBE STREET
� ' (34.5' BC-BC)_
�� r.i iRa
W WATER LINE
The lowest elevation to have gravity sanitary sewer service must
be more than one (1) foot above the lowest top of casting
elevation of either the first upstream or downstream manhole on
the main line sewer to which the connection is made.
Flood Hazard Note:
Lot Number 559 lies within Flood Hazard Zone "X" per the
scaled location on the Flood Insurance Rate Maps for Hamilton
County, Indiana (Community Panel 18057CO205G, dated
November 19, 2014).
Note:
This document has been prepared for the benefit of the parties indicated hereon,
for the express use of obtaining a residential building permit.
This document has been prepared and based upon the construction documents,
record drawings, and additional information prepared for this development by
others. This document is not based upon a field survey and Coor Consulting
does not warrant the accuracy or completeness of this information.
0
c�o��a0�o�g � D�a�c� �c�r��oc�c��g
C� O C� [� O G' �� 0 O Cr�
303 WEST MAIN STREET KNIGHTSTOWN. INDIANA
(888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692
DATE: 10/26/16 JOB #2016-106 REVISIONS:
Note:
Minimum Front Yard - 20'
Minimum Side Yard - 5' or 8%
Minimum SY Aggregate - 15' or 81 %
Minimum Rear Yard - 20'
LOT # 559
±8, 855 S F
NO PAD PER PLAN
SAN MH D425
TC=902.74
Note:
Q��ac,�c�c�
�c����o ���
Note:
�]or��[�
_ �30'
Contractor should verify sump
pit location with Field Manager.
XX.X = Proposed Grade
Per Plans
� = Drainage Flow
— SF — = Proposed Silt Fence
Contractor should verify site specific information depicted hereon with the
approved construction plans for this development in regards to sidewalk and
handicap ramp placement, widths, and construction. Contractor should verify site
specific information in regards to erosion control placement and materials. Also,
Contractor should reference Architectural plans for foundation orientation and
dimensions.
Unless otherwise stated hereon, no information pertaining to but not
The contractor/owner should verify existing conditions prior to construction. Any
varying field conditions or any discrepancy with the information contained hereon
should be immediately reported to COOR Consulting & Land Services, Corp.;
failure to do so would result in the contractor/owners assumption of liability.
Note:
Unless otherwise stated hereon, no information pertaining to but not limited to,
fluctuating water tables elevations, soil types, and conditions within the building
areas of this development have been provided and\or referenced on said
documents. With the excavation of the proposed structure foundations, certain
care and observations should be made in regard to such conditions as soil types
and fluctuating water tables. During the excavation process should any
unsuitable soils or ground water be witnessed, the builder shall be immediately
notified for further examination and consultation. At the builders discretion,
additional construction techniques may be necessary to alleviate future
problems.
VILLAGE OF PLOT PLAN
WESTCLAY Prepared For:
SECTION 8501
P.C. 2, SLIDE 642
INSTR #200500050871 EVAN J. DENNIS
"PHILLIPS HOME"
LOT # 559
2396 GLEBE STREET
CARMEL, IN 46032