Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
16120034 Building Plans
MICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507DateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:38 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtG0.0Cover SheetDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set"Drawing IndexSheetNumberSheet NameG0.0 Cover SheetG0.1 Life Safety Plan - Fourth FloorG0.5 Abbreviations & General InformationG0.6 Wall TypesA1.4 Fourth Floor PlanA1.4D Fourth Floor Dimensional PlanA2.4 Fourth Floor Reflected Ceiling PlanA4.1 Enlarged Restroom Plans & ElevationsA4.2 Enlarged Restroom Plans, Elevations & SectionsA4.3 Enlarged Casework Plans, Elevations & SectionsA5.1 Plan DetailsA6.1 Room Finish Schedule & LegendA6.2 Fourth Floor Finish PlanA6.3 Door and Storefront Schedules & ElevationsA6.4 Furniture Plan - Fourth FloorM0.4 Mechanical General InformationMD1.4 Fourth Floor Mechanical Demolition PlanM1.4 Fourth Floor Mechanical PlanM2.4 Roof Mechanical PlanM5.4 Mechanical DetailsM6.4 Mechanical SchedulesE0.4 Electrical General InformationED1.4 Fourth Floor Electrical Demolition PlanE1.4 Fourth Floor Lighting PlanE2.4 Fourth Floor Power & Systems PlanE5.4A Electrical DetailsE5.4B Fire Alarm General Notes and DiagramsE6.4A Electrical SchedulesE7.4A Electrical DiagramsE7.4B Power Riser DiagramP0.4 Plumbing General Information SheetPD1.3 Third Floor Plumbing Demolition PlanPD1.4 Fourth Floor Plumbing Demolition PlanP1.3 Third Floor Plumbign PlanP1.4 Fourth Floor Plumbing PlanP3.4 Plumbing Riser DiagramsP4.4 Plumbing Enlarged PlansP5.4 Plumbing DetailsP6.4 Plumbing SchedulesF0.4 Fire Protection General Information SheetF1.4 Fourth Floor Fire Protection Plan55 East 111th StreetIndianapolis, IN 46280100% Bid Set - October 3, 2016Project TeamArea MapProject LocationArchitect55 Monument CircleSuite 1212Indianapolis, IN 46204(317) 348-1000Interior DesignerMEP Engineer8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-2222No. Date Description Office434BOffice433BOffice432BElevator Lobby401BWork Area/Storage423BOffice430BR.R.415BR.R.416BIT/Elec413BStorage414BOffice412BOffice411BOffice410BVault418BOffice406BOffice405BOffice419BOffice420BOffice404BOffice403BOffice421BOffice409BOffice408BOffice407BW.R.R.426BM.R.R.427BJan.425BOffice424BIDF428BMeeting431BInternal Controls435BRestroom Corridor429BCustomerSolutions422BKitchenette417BAccounting/Financial402B2 Hr2 Hr90 Min2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr2 Hr90 Min2 Hr2 Hr2 Hr2 Hr2 HrX1X1X2X2X3X3X4X4X5X5X6X6X7X7X8X8XAXAXA.4XA.4XBXBXCXCXDXDXEXEXFXFXF.6XF.6XGXGXHXHXIXIXJXJ±135'-0"±101'-0"1 Hour Fire Rated Wall2 Hour Fire Rated WallPath of Egress and Distance±6'-0"Direction of Egress at Exit DoorLife SafetySymbol LegendSmoke Partition - All doors in wall must be self-closing and be equipped with smoke gasketsDirection of Egress Between BuildingsAccess to Egress Stair with Exterior Exit at GradeFire Extinguisher Cabinet - Semi RecessedA.2014 INDIANA BUILDING CODEB.BUILDING SQUARE FOOTAGE - ENCLOSEDExisting Lower Level16,347 SFExisting First Floor16,429 SFExisting Second Floor13,955 SFExisting Third Floor15,343 SFExisting Fourth Floor1,727 SFTOTAL BUILDING77,418 SFC.EXTERIOR SQUARE FOOTAGE - ANCILLARYNorth West Areaway55 SFElevated Patio1,864 SFExterior Stairs171 SFCurved Canopy779 SFEntry Canopy252 SFEmployee Entry Canopy1,162 SFTOTAL4,290 SFD.BUILDING TYPE & OCCUPANCYConstruction Type:II ABuilding Occupancy:B, A-3, F-1Building is non-separated use per 508.3E.ALLOWABLE HEIGHTPer Table 5033 Stories and 65 FeetIncrease per 504.21 Story and 20 FeetTotal4 Stories and 85 FeetF.AREA OF BUILDING (ALLOWABLE)Tabular Area (Table 503)15,500 SFFrontage Increase10,850 SFSprinkler Increase31,000 SFAllowable Per Floor57,350 SFAllowable Area Per Building3 X 57,350 (Table 503, 506.3)172,050 SFG.PEDESTRIAN WALKWAY (SECTION 3104)1.Pedestrian Walkway shall not contribute to thebuilding area or the number of stories ofconnected buildingsLower Level959 SFFirst Floor1,131 SFSecond Floor1,279 SFTOTAL WALKWAY3,369 SF2.Connected Buildings shall be consideredseparate structures3.The Pedestrian walkway shall be noncombustible constructionH.AUTOMATIC SPRINKLERS1.Connecting Walkway and New Building to havea full automatic sprinkler system installed perNFPA 13.2.Existing Building has a full automatic sprinklersystem already installed.Building Code AnalysisI.EGRESS SIZINGSee Sheet G-013 for Occupancy, door and exit stair widthcalculations. See sheet G-014 for comparison of exitwidth totals and actual widths provided.K.TRAVEL DISTANCETravel distance to an exit from any point must notexceed 250 FT per Table 1016.2Actual travel distances shown on plan1.2.J.EGRESS CONVERGENCEEgress from above and below converge at the first floor ofStair 1 and Stair 2. Exit width from stairs shows that theexterior doors as detailed exceed the existing requirementsof the Lower Level and Second floor per 1005.6L.INCIDENTAL USEPer IBC Sec. 509.4.2, Incidental Use rooms shall havewalls extended to deck as a non-rated smoke partition, withself-closing doors tested in accordance with UL 1784 forair leakage rate. Penetrations through smoke partitions arerequired to be sealed but dampers are not required underSec. 509.4.2 (with Indiana Amendments).M.ELEVATOR LOBBIESElevator lobbies are not required to be enclosed per IBCSec. 713.14.1 Exception #4.Fourth Floor Renovation13,616 SFA.UL-Tested Fireproofing Chart (for 1-hr ratings)Building Columns (all)UL X790Floor Supports (spray)UL D759Floor Supports (intumescent)UL N614FireproofingC.INTUMESCENT FIREPROOFINGB.SPRAY FIREPROOFINGSpray fireproofing shall occur at the followinglocations: all building columns; First Floorframing; Second Floor framing; Third Floorframing; Fourth Floor framing; roof decksD.SPECIFICATIONSSpray or applied fireproofing shall be applied asdescribed per manufacturer specifications. Referto specification manual for additional information.Refer to UL and manufacturer charts for thicknessreference based upon structural member or decksizing for 1 hour rated construction. Submitproduct data for approval.Intumescent fireproofing shall occur at thefollowing locations: All diagonal bracing.Add Alternate: 2nd Floor Framing at exposedceilings overlapping suspended ceilings by 4'-0".Roof Deck & BeamsUL S721Diagonal Bracing (intumescent)UL X650E.PEDESTRIAN CONNECTORNo spray fireproofing or other protective meansis required at the Pedestrian Connector onfloors Lower Level, First, and Second Floor,north of Grid 9.MICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507ABArea of WorkKey PlanDateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:44 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtG0.1Life Safety Plan -Fourth FloorDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set" 1/8" = 1'-0"1Fourth Floor Life Safety PlanLife Safety General Notes1 Ratings shown are minimum requirements. See wall types for wallconstruction.2 Doors in fire rated walls to be fire rated per code to maintain wallrating.3 Applicable codes are as follows:A Building Code: Indiana Building Code, 2014 Edition (IBC, 2012Edition, 1st printing) ANSI A117.1-2009B Structural Code: Indiana Building Code, 2014 Edition (IBC, 2012Edition, 1st printing) ANSI A117.1-2009C Plumbing Code: Indiana Plumbing Code, 2012 EditionD Mechanical Code: Indiana Mechanical Code, 2014 Edition (IMC,2012 Edition, 1st printing)E Electrical Code: Indiana Electrical Code, 2009 Edition (NFPA70-2008F Fire/Life Safery Code: Indiana Fire Code, 2014 Edition (IFC 2012Edition, 1st printing)G Accessibility Code: Indiana Building Code, 2014 Edition (IBC,2012 Edition, 1st printing) ANSI A117.1-2009H Energy Conservation Code: Indiana Energy Conservation Code2010 (ASHRAE 90.1, 2007 edition, as amended)I Elevator Code: Indiana Elevator Safety Code (ANSI/ASMEA17.1, 2004, as amended & ANSI/ASME A17.1, 2007, asamended)J Fuel Gas Code: Indiana Fuel Gas code, 2014 Edition (IFGC,2012 Edition, 2nd printing)K Selected NFPA Standards as outlined athttp://www.in.gov/dhs/2490.htmOccupancy & Exiting Area TotalsLevel Location OccupancyCalculated ValuesOccupants Horizontal Width (inches) Stair Width (inches)Lower Level Interior F-1 142 21.3 28.4First Floor Interior A-3 761 114.15 152.2Second Floor Interior A-3 440 66 88Second Floor Plaza Deck A-3 0 0 0Third Floor Interior B 168 25.2 33.6Fourth Floor Interior B 152 22.8 30.4Provided Horizontal Exit Width Per FloorDoor Number Level Door Width Egress WidthS1-0 Lower Level 3' - 0" 32"S2-0 Lower Level 3' - 0" 32"Lower Level64"101A First Floor 6' - 0" 68"101C First Floor 8' - 0" 92"101D First Floor 8' - 0" 92"103A First Floor 6' - 0" 68"105A First Floor 3' - 0" 32"111A First Floor 6' - 0" 68"113A First Floor 6' - 0" 68"S1-1 First Floor 3' - 0" 32"S2-1B First Floor 3' - 0" 32"First Floor552"S1-2 Second Floor 3' - 0" 32"S2-2 Second Floor 3' - 0" 32"Second Floor64"S1-3 Third Floor 3' - 0" 32"S2-3 Third Floor 3' - 0" 32"Third Floor64"S1-4 Fourth Floor 3' - 0" 32"S2-4 Fourth Floor 3' - 0" 32"Fourth Floor64"Occupancy & Exiting Area ScheduleOccupancyRoomGross AreaNonCalculatedRoom AreaNet Area ClassificationCalculated ValuesNumber NameOccupantsExitCapacity -HorizontalExitCapacity- StairsB 401 Elevator Lobby 165.17 SF 0.00 SF 165.17 SF Business areas 2 0.3 0.4B 402 Accounting/ Financial 5208.58 SF 0.00 SF 5208.58 SF Business areas 53 7.95 10.6B 403 Office 143.92 SF 0.00 SF 143.92 SF Business areas 2 0.3 0.4B 404 Office 142.36 SF 0.00 SF 142.36 SF Business areas 2 0.3 0.4B 405 Office 143.92 SF 0.00 SF 143.92 SF Business areas 2 0.3 0.4B 406 Office 141.91 SF 0.00 SF 141.91 SF Business areas 2 0.3 0.4B 407 Office 166.63 SF 0.00 SF 166.63 SF Business areas 2 0.3 0.4B 408 Office 144.73 SF 0.00 SF 144.73 SF Business areas 2 0.3 0.4B 409 Office 167.08 SF 0.00 SF 167.08 SF Business areas 2 0.3 0.4B 410 Office 175.34 SF 0.00 SF 175.34 SF Business areas 2 0.3 0.4B 411 Office 151.64 SF 0.00 SF 151.64 SF Business areas 2 0.3 0.4B 412 Office 174.64 SF 0.00 SF 174.64 SF Business areas 2 0.3 0.4B 413 IT/Elec 93.69 SF 0.00 SF 93.69 SF Business areas 1 0.15 0.2B 414 Storage 55.89 SF 0.00 SF 55.89 SF Business areas 1 0.15 0.2B 415 R.R. 50.20 SF 0.00 SF 50.20 SF Business areas 1 0.15 0.2B 416 R.R. 84.05 SF 0.00 SF 84.05 SF Business areas 1 0.15 0.2B 417 Kitchenette 153.18 SF 0.00 SF 153.18 SF Business areas 2 0.3 0.4B 418 Vault 141.91 SF 0.00 SF 141.91 SF Business areas 2 0.3 0.4B 419 Office 143.92 SF 0.00 SF 143.92 SF Business areas 2 0.3 0.4B 420 Office 142.36 SF 0.00 SF 142.36 SF Business areas 2 0.3 0.4B 421 Office 143.92 SF 0.00 SF 143.92 SF Business areas 2 0.3 0.4B 422 Customer Solutions 3032.78 SF 0.00 SF 3032.78 SF Business areas 31 4.65 6.2B 423 Work Area/ Storage 317.72 SF 0.00 SF 317.72 SF Business areas 4 0.6 0.8B 424 Office 145.22 SF 0.00 SF 145.22 SF Business areas 2 0.3 0.4B 425 Jan. 28.12 SF 0.00 SF 28.12 SF Business areas 1 0.15 0.2B 426 W.R.R. 211.25 SF 0.00 SF 211.25 SF Business areas 3 0.45 0.6B 427 M.R.R. 166.24 SF 0.00 SF 166.24 SF Business areas 2 0.3 0.4B 428 IDF 65.43 SF 0.00 SF 65.43 SF Business areas 1 0.15 0.2B 429 Restroom Corridor 293.50 SF 0.00 SF 293.50 SF Business areas 3 0.45 0.6B 430 Office 122.53 SF 0.00 SF 122.53 SF Business areas 2 0.3 0.4B 431 Meeting 103.06 SF 0.00 SF 103.06 SF Business areas 2 0.3 0.4B 432 Office 150.84 SF 0.00 SF 150.84 SF Business areas 2 0.3 0.4B 433 Office 142.83 SF 0.00 SF 142.83 SF Business areas 2 0.3 0.4B 434 Office 141.68 SF 0.00 SF 141.68 SF Business areas 2 0.3 0.4B 435 Internal Controls 583.00 SF 0.00 SF 583.00 SF Business areas 6 0.9 1.2B 13439.24 SF 13439.24 SF 152 22.8 30.4Provided Horizontal Exit Width From StairsDoor Number Level Door Width Egress WidthS1-1A First Floor 4' - 0" 44"S2-1A First Floor 6' - 0" 68"112"Provided Horizontal Exit Width From Plaza DeckDoor Number Level Door Width Egress Width202 Second Floor 3' - 0" 32"208A Second Floor 3' - 0" 32"64"Provided Exit Width Per Stair RunStairStringerWidthDistanceBetweenStringersTotal StairWidthHandrailDiameterHandrailWall OffsetEgress WidthExterior EgressWidthStair 1 0' - 2" 4' - 0" 4' - 4" 1 1/2" 0' - 2 1/2" 44" 0"Stair 2 0' - 2" 5' - 6" 5' - 10" 1 1/2" 0' - 2 1/2" 62" 0"Stair 3 0' - 3" 5' - 0" 5' - 6" 1 1/2" 0' - 5 3/4" 0" 0"106" 0"Stair 4 0' - 3" 4' - 6" 5' - 0" 1 1/2" 0' - 2 1/2" 0" 52"0" 52"Note: Stair 3 is for convenience only and is not required as part of exit calculations.Existing Exiting ProvidedGross Building AreaName Area PerimeterExisting Mechanical Areaway 55 SF 32' - 0"Existing Area Covered by Curved Canopy 779 SF 125' - 3 1/32"Existing Area Covered by Employee Entry Canopy 1162 SF 284' - 5 7/16"Existing Area Covered by Entry Canopy 252 SF 76' - 5 19/32"Existing Elevated Patio 1864 SF 227' - 8 27/32"Existing Exterior Stairs 177 SF 75' - 5"4290 SFExterior Area 4290 SFExisting Lower Level 16347 SF 537' - 10"Existing First Floor 16429 SF 550' - 2 1/2"Existing Second Floor 13955 SF 511' - 11 31/32"Existing Third Floor 15343 SF 539' - 6"Existing Fourth Floor Perimeter 1378 SF 539' - 6"Existing Fouth Floor Core 349 SF 87' - 1 3/4"Fourth Floor Renovation 13616 SF 615' - 0 15/32"77418 SFExisting Pedestrian Connector - Lower Level 959 SF 146' - 9 1/4"Existing Pedestrian Connector - First Floor 1131 SF 168' - 6 11/32"Existing Pedestrian Connector - Second Floor 1279 SF 184' - 6 15/16"3369 SFGross Building Area 80787 SFNo. Date Description 1i1011tRoom name101A1011SIM1View Name1/8" = 1'-0"?Key Symbol Legend1RefSection DesignationModifier (SIM or TYP)Detail NumberSheet NumberDirection of ViewLine of Cut1A101SIMElevation Height DesignationDescription of ObjectHeight of ObjectNameElevationKey Note TagWall Construction Type TagDoor Number DesignationWindow Number DesignationRoom Number DesignationRoom NameRoom NumberDrawing View DesignationView TitleView ScaleView NumberEnlarged View DesignationModifier (SIM or TYP)View NumberSheet NumberArea of EnlargementElevation DesignationModifier (SIM or TYP)Sheet NumberDirection of ViewView NumberSIMA101ApproachApproach60"48"ClearFloorSpaceClearFloorSpaceMIN18"closer and a latch12" If door has both aClearFloorSpaceClearFloorSpaceClearFloorSpaceClearFloorSpaceApproachApproachApproachApproach48" MIN42" MIN54" MIN If door has a closer48" MIN If door has a closer24" MINNote:36" MIN If 60" clear or 42" MIN if 54" clear22" MIN54" MINa latch and closer48" MIN If door has both42" MIN36" MIN42" MIN54"60"ApproachExitClearFloorSpace60"60"60" MIN60" MIN36" MIN24" MIN36" MINMIN12"MIN12"ApproachExitClear Floor SpaceApproachClearFloorSpaceLavitory42" Min12" Max39"-41"54" Min6" Max36" Min7"-9"16"-18"56" Min60" Min7"-9"42" Min12" Max39"-41"52" Min48" Min (Other Approach)42" Min (Latch Approach)Mfg'rPer59" Min (Floor Mounted WC)56" Min (Wall Mounted WC)ApproachAlternateApproachAlternatedoor location36" Min6" Max16"-18"48" Min (Other Approach)42" Min (Latch Approach)Mfg'rPer60" Min42" Min4" Max32" Min4" Max32" MinClearFloorSpaceClearFloorSpaceApproach16"-18"6" Max36" Min60" MinWall or Floor Mounted WC56" Min42" Min12" Max39"-41"54" Min7"-9"36" Min7"-9"Per ADA Door Clearance42" Min (Latch Approach)Mfg'rPer60" MinApproach35"-37"32" MinClearFloorSpace17"-19"42" Min12" Max52" Min42" Min12" Max52" Min (Other Approach)Install if total WC and Urinalcount for restroom is equalto or greater than 6 fixtures17"-19"2'-2" Prefered15"-48" to Outlet33"-36"39"-41"18" Min12" Min42" Min39"-41"54" Min7"-9"12" Min12" Min36" Min36" Min33"-36"Flush valve water closets shown forillustration purposes - see plumbingfixture schedule for correct fixture type.Grab barextends ontransfer sideToilet paperdispencer2"Sanitary napkindisposal - align topwith top of toiletpaper dispencerBack WallSide WallClearFloorSpace30" Min48" Min *± 10"24" Max5" Max15" Min38"-48" for Second36" Max to Spout OutletWhere Provided -See PlanKnee Clear8" MinToe Clear6" MaxKnee Clear11" Min* Coordinate depth with actualknee and toe clearance providedKnee Clear27" MinToe Clear9" MinPlan ViewSide ViewPer Manufacturer4" MinAs RequiredManufacturerPer4" Max54" Max (ADA Side Reach) 60" Max (NFPA)4" MaxPer Manufacturer4" MinAs RequiredManufacturerPer54" Max (ADA Side Reach) 60" Max (NFPA)SectionElevationSectionElevationFramed WallBlock Wall17" Min.Max*17"-25"48" Min30" MinPlan ViewSide ViewKnee Clear27" MinKnee Clear8" MinMirrorDepth17" MinToe Clear6" MaxToe Clear9" Min29" Min34" Max40" Max* Coordinate depth with actualknee and toe clearance providedKnee Clear11" Minas Req'dBaseAbove15" Min48" MaxFront ViewShelfHooksShelfAdditional non-compliant lockersas requiredFloor42" Prefered44" MaxSoapDispenserFront ViewCenterlineof button30" Max4" Min48" MaxTowel DispenserCenterline of OutletWasteRecepticleFront ViewFront ViewWithoutWaste RecepticleWithWaste RecepticleClearFloorSpace48" MinEQEQ30" Min17" Max (ADA)24" (Typ)Install minimum of (1) one urinal at ADAheight per restroom where shown on planSide ViewPlan ViewWall as scheduled - see foor planSide Wall ContinuesFace Wall ContinuesHollow metal door frame with(3) jamb anchors per sideDoor per schedule - hingeside shownTaped & finished metalcorner bead at all cornersWall as scheduled - see foor planTriple studs at hinge side ofjamb and boxed studs at wallintersection as required forgypsum board edge support(Typ)4 7/8"(Typ)4 7/8"MICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507DateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:45 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtG0.5Abbreviations &General InformationDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set"General AbbreviationsAbbreviation Description&And@AtA/C Air ConditioningACM Asbestos Containing MaterialsACT Acoustical Ceiling TileADJ Adjacent, AdjustableADMIN AdministrationAFF Above Finish FloorAIA American Institute of ArchitectsALT AlternativeALUM AluminumAPP'D ApprovedARCH ArchitecturalAUTO AutomaticAVG AverageBD BoardBLDG BuildingBLKG BlockingBOT BottomCAB CabinetCHK'D CheckedCJ Control JointCL Center LineCLG CeilingCLO ClosetCMU Concrete Masonry UnitCOL ColumnCONC ConcreteCONT ContinuousCOORD CoordinateCPT, CRPT CarpetCTR CenterCW Cold WaterDDepthDEMO DemolitionDF Drinking FountainDIA, Ø DiameterDIM DimensionDN DownDR DoorDS DownspoutDTL DetailDWG DrawingEA EachEJ Expansion JointELEC ElectricalELEV Elevator, ElevationEOB End of BusinessEPDM Ethylene Propylene Diene Monomer (Single PlyRoof Membrane)EQ EqualEQPM EquipmentEX, EXST ExistingEXT ExteriorFAX FacsimileFD Floor DrainFDN, FDTN FoundationFE Fire ExstinguisherFIN FinishFLR FloorFM Factory Mutual Insurance, FM GlobalFT (') Foot or FeetFTG FootingGA GaugeGAL GallonGALV GalvanizedGC General ContractorGEN GeneralGMU Glazed Masonry UnitGYP Gypsum, Gypsum BoardHB Hose BibHDW HardwareHM Hollow MetalHORZ HorizontalHT, HGT HeightHVAC Heating Ventilation and Ait ConditioningHW Hot WaterID Inside DiameterIN (") Inch or InchesINSUL InsulationINT InteriorJAN JanitorKO Knock OutL LengthLAV LavitoryLB PoundLCD Liquid Crystal DisplayLH Left handMATL,MAT'LMaterialMAX MaximumMECH MechanicalMFR ManufacturerMH Man HoleMIN MinimumMISC MiscellaneousMNRY MasonryMRR Men's RestroomN/A Not ApplicableNIC Not In ContractNO (#) NumberNOM NominalNTS Not to ScaleOC On CenterOD Outside DiameterOPNG OpeningOPP OppositeP LAM Plastic LaminatePLUM PlumbingPR PairPROC ProcessingPSF Pounds per Square FootPSI Pouns per Square InchPTR PrinterQTY QuantityRRadiusRD Roof DrainREC ReceptionREQ, REQ'D RequiredREV Revise, RevisionRH Right HandRM RoomRO Rough OpeningRR RestroomSECT SectionSF Square Foot, Square Feet ,Square FootageSHT SheetSIM SimilarSPEC SpecificationSQ SquareSS Stainless SteelSTD StandardSTL SteelSTOR, STRG StorageTTemperedT & B Top and BottomT & G Tongue and GrooveTBD To Be DeterminedTEL TelephoneTELCOM TelecommunicationsTEMP TemporaryTHK Thick, ThicknessTHRU ThroughTYP TypicalUL Underwriters LaboratoriesUNO Unless Noted OtherwiseVCT Vinyl Composite TileVERT VerticalWWidthW/ WithW/O WithoutWC Water ClosetWD WoodWIN, WDW WindowWRR Women's RestroomWT Weight 1/2" = 1'-0"1ADA Door Clearance 1/2" = 1'-0"17ADA Turning Clearance 1/2" = 1'-0"18ADA Turning Clearance - Alt 1/2" = 1'-0"7ADA Toilet without Stall Detail 1/2" = 1'-0"8ADA Wheelchair Toilet Stall Detail 1/2" = 1'-0"9ADA Wheelchair End Toilet Stall Detail 1/2" = 1'-0"10ADA Ambulatory Toilet Stall Detail 1/2" = 1'-0"11ADA Toilet Accessory Mounting Detail 1/2" = 1'-0"6ADA Drinking Fountain Detail 1/2" = 1'-0"12ADA Fire Exstinguisher Mounting Detail 1/2" = 1'-0"4ADA Lavatory Detail 1/2" = 1'-0"16ADA Locker Detail 1/2" = 1'-0"14ADA Soap Dispenser Mounting Detail 1/2" = 1'-0"13ADA Towel Dispenser Mounting Detail 1/2" = 1'-0"5ADA Urinal Detail 1 1/2" = 1'-0"2Hinge Side Standard Offset and FramingNo. Date Description 6"6"6"6"6"6"6'-0"1"6"0GC1A0GC3A0GC3B0GC6A0GC6B0GF3B 0GF3A0GF6A0GP3A0GP3B0OCXA0OFXASECTIONPLANSECTION5/8" Type X gypsum board - accessible side15/8" Runner track with floor anchors permanufacturerFloor finish and base as scheduledCeiling as scheduled5/8" Type X gypsum board - accessibleside15/8" Metal stud, 25 GA. at 16" o.c.Tie top of wall to full height wall or brace to structureas required to avoid movement15/8" Runner trackSECTIONPLANSECTION5/8" Type X gypsum board - accessibleside35/8" Runner track with flooranchors per manufacturerFloor finish and base as scheduledCeiling as scheduled5/8" Type X gypsum board - accessible side35/8" Metal stud, 25 GA. at 16" o.c.Tie top of wall to full height wall or brace tostructure as required to avoid movement35/8" Runner trackSECTIONPLANSECTION5/8" Type X gypsum board - each side35/8" Runner track with floor anchorsper manufacturerFloor finish and base as scheduledCeiling as scheduled5/8" Type X gypsum board - each side35/8" Metal stud, 25 GA. at 16" o.c.Tie top of wall to full height wall or brace tostructure as required to avoid movement35/8" Runner trackSECTIONPLANSECTION5/8" Type X gypsum board - accessible side6" Runner track with floor anchorsper manufacturerFloor finish and base as scheduledCeiling as scheduled5/8" Type X gypsum board - accessible side6" Metal stud, 25 GA. at 16" o.c.Tie top of wall to full height wall or brace tostructure as required to avoid movement6" Runner trackSECTIONPLANSECTION5/8" Type X gypsum board - each side6" Runner track with floor anchorsper manufacturerFloor finish and base as scheduledCeiling as scheduled5/8" Type X gypsum board - each side6" Metal stud, 25 GA. at 16" o.c.Tie top of wall to full height wall or brace tostructure as required to avoid movement6" Runner trackSECTIONPLANSECTION SECTION5/8" Type X gypsum board - each side35/8" Runner track with floor anchorsper manufacturerFloor finish and base as scheduledCeiling as scheduledBottom of structure35/8" Deflection track anchored to structureper manufacturer5/8" Type X gypsum board - each side35/8" Metal stud, 25 GA. at 16" o.c.5/8" Type X gypsum board - accessible sideSECTIONPLANSECTION SECTION35/8" Metal stud, 25 GA. at 16" o.c.35/8" Runner track with floor anchorsper manufacturerFloor finish and base as scheduledCeiling as scheduledBottom of structure35/8" Deflection track anchored tostructure per manufacturer5/8" Type X gypsum board - accessible sideSECTIONPLANSECTION SECTION5/8" Type X gypsum board - each side6" Runner track with floor anchorsper manufacturerFloor finish and base as scheduledCeiling as scheduledBottom of structure6" Deflection track anchored to structureper manufacturer5/8" Type X gypsum board - each side6" Metal stud, 25 GA. at 16" o.c.SECTIONPLANSECTION5/8" Type X gypsum board extend fromfloor to min 6" above ceiling -accessible side35/8" Runner trackTie new studs to existing window sill interior wallCeiling as scheduled - top of opening may notmatch ceiling height5/8" Type X gypsum board - accessible side35/8" Metal stud, 25 GA. at 16" o.c.Tie top of wall to existing window head interiorwallSECTIONPLANSECTION5/8" Type X gypsum board - each side35/8" Runner track with floor anchorsper manufacturerFloor finish and base as scheduled5/8" Type X gypsum board - each side35/8" Metal stud, 25 GA. at 16" o.c.35/8" Runner track35/8" Runner trackBlack rigid insulation - match thickness toexistingBlack rigid insulation - match thickness toexistingThermal batt insulation - match thickness toexisting and stud cavity availableSeamed brake metal with ±1" reveal at edgesand concealed fastenersSECTIONPLANSECTION5/8" Type X gypsum board - accessible sideExisting runner track anchored to structureFloor finish and base as scheduledCeiling as scheduled5/8" Type X gypsum board - accessiblesideExisting metal studsExisting runner track5/8" Type X gypsum board - accessiblesideSECTIONPLANSECTION SECTIONExisting metal studsExisting runner track anchored to floorFloor finish and base as scheduledCeiling as scheduledBottom of structureExisting deflection track anchored to structure5/8" Type X gypsum board - accessible sideWall Type QuickReference Notes0GF3AFire RatingPartition Vertical ExtentDetail Identifier CharacterPartition Structural MaterialNominal Structural WidthFire Rating:(See Detail for UL Rating)0Non-Rated1One Hour Rated2Two Hour Rated3Three Hour Rated4Four Hour RatedSSmoke Barrier RatedStructural Material:GGypsum/metal stud partitionWGypsum/wood stud partitionMConcrete masonry unitSShaft wallOOther (see detail for additional info)Vertical Extent:FFull height (to structure above)CTo x inches above ceiling (6" forgypsum, 8" for masonry)BBraced to structure (gypsum to 12"above ceiling)OOffset (see detail)RTo rated lidSTo intermediate structure abovePPartial height wall (see detail forheight and top finish)Nominal Width:MarkMetalWoodMnry Shaft07/8"*---11-5/8"3/4"--22-1/2"1-1/2"2-1/4"2-1/2"33-5/8"---44"3-1/2"3-5/8"4"66"5-1/2"5-5/8"6"88"7-1/4"7-5/8"-1010"9-1/4"9-5/8"-1212"11-1/4"11-5/8"-XNon-Structural (see detail forwidth)* Hat channel furringMICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507DateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:46 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtG0.6Wall TypesDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set"Wall Type General Notes1 Use moisture resistant gypsum board in all restrooms andbehind all other plumbing fixture locations where gypsum boardis called for in all wall types2 Install one (1) layer of gypsum board (0OCXA or 0OFXA)onaccessible sides of all existing rough framed walls - unlessnoted otherwiseWall Type ScheduleTypeMarkType Count0GC1A Interior - 1-5/8" Mtl. Stud w/GWB one sideceiling1500GC3A Interior - 3-5/8" Mtl. Stud w/GWB one sideceiling50GC3B Interior - 3-5/8" Mtl. Stud w/GWB each sideceiling340GC6A Interior - 6" Mtl. Stud w/GWB one side ceiling 10GC6B Interior - 6" Mtl. Stud w/GWB each side ceiling 10GF3A Interior - 3-5/8" Mtl. Stud w/GWB one side full 20GF3B Interior - 3-5/8" Mtl. Stud w/GWB each side full 170GF6A Interior - 6" Mtl. Stud w/GWB each side full 70GP3A Interior - 3-5/8" Mtl. Stud w/GWB one sidepartial40GP3B Interior - 3-5/8" Mtl. Stud w/GWB each sidepartial20OCXA Interior - 5/8" Gypsum for existing studs ceiling 10OFXA Interior - 5/8" Gypsum for existing studs full 710A Interior - 2.5" C-H Stud w/GWBx2 1 side, 1"GWB 1 side (2-Hr)2No. Date Description S3'-6"DOOR WIDTHINTERIOR DEPTH 5'-61_8" 8 4'-43_4"71_4"HOISTWAY DEPTH 6'-11"HSCoptional wall CWire rack 48x24 Wire rack 48x24Storage Cabinet 60x20Storage Cabinet 48x20 Storage Cabinet 48x20 Storage Cabinet 48x20ProductRack24x15ProductRack30x24Storage Cabinet 48x20Storage Cabinet 48x20 Storage Cabinet 48x20Storage Cabinet 48x20Storage Cabinet 48x20Storage Cabinet 48x20REF.REF.ICETrashElevatorELEV 2ElevatorELEV 1StairSTR 2StairSTR 1S1-4S2-4ELEVELEV0GC3B0GF3B0GF3B432433434Office434Office433Office4320GC1AElevator Lobby401Work Area/Storage423Office430R.R.415R.R.416IT/Elec413Storage414Office412Office411Office410Vault418Office406Office405Office419Office420Office404Office403Office421Office409Office408Office407W.R.R.426M.R.R.427Jan.425Office424IDF428Meeting431Internal Controls435Restroom Corridor429CustomerSolutions422Kitchenette417Accounting/Financial402431428426427425424430421420419418416415413412411410409408407406405404403414A4.11A4.21A4.31A5.17A5.11A5.12A5.16A5.15A5.14A5.13X1X1X2X2X3X3X4X4X5X5X6X6X7X7X8X8XAXAXA.4XA.4XBXBXCXCXDXDXEXEXFXFXF.6XF.6XGXGXHXHXIXIXJXJ0GC3B0GC3B0GC3B0GC3B0GC3B0GF3B0GF3B0GC3B0GC3B0GF3B0GF3B0GC3B0GC3B0GC6A0GC3B0GC3B0GC3B0GF3B0GF3B0GF3B0GF3B0GC3B0GC3B0GF3B0GF3B0GC3B0GC3B0GC3B0GP3B0GC3B0GC3B0GC3B0GP3B0GC3B0GC3B0GC3B0GC3B0GC3B0GC3B0GC3BA5.15SimA5.15SimA5.13SimA5.17Sim2A1.4A5.16SimTypUNOTyp at column linesX1 and X8 UNOA5.15SimA5.17SimA5.15SimA5.15SimA5.15SimA5.17SimA5.17SimA5.15SimA5.16SimA5.13SimA5.13Sim0GF3BA5.13SimA5.15SimA5.16SimA5.16SimTyp atperimeterwall0GP3A0GP3AVerify existing installation priorto installation of new walls -install additional black insulationas directed by architect in fieldto prevent wall structures beingvisable through glassVerify existing installation prior toinstallation of new walls - installadditional black insulation as directedby architect in field to prevent wallstructures being visable through glass0GP3AVerify existing installation prior toinstallation of new walls - installadditional black insulation as directedby architect in field to prevent wallstructures being visable through glassA5.17SimFourth Floor43' - 6"Top of Steel (High)57' - 0"± 9" VIF± 9" VIFExisting storefront window systemExisting precast concrete panelsExisting precast concrete panelsNew 5/8" type X gypsum boardover existing vapor retarder, 6"batt insulation, and metal studs -coordinate electrical and telecomrough-in prior to installationInstall owner provided brakemetal sill - match length ofreturns to similar items installedon the third floor as requiredNew lay-in ceiling and associatedtrims per ceiling planNew 5/8" type X gypsum board and6" batt insulation installed atexisting metal studs - coordinateelectrical and telecom rough-inprior to installation. Paint finish tomatch wall color, typ.0' - 6" MinSealant jointSealant jointXExisting metal studs with battinsulation and vapor barrierExisting metal studs with battinsulation and vapor barrier9' - 6" Floor Deck to Fin. CeilingRubber cove baseMICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507ABArea of WorkKey PlanDateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:10 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtA1.4Fourth Floor PlanDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set" 1/8" = 1'-0"1Fourth Floor Plan 3/4" = 1'-0"2Wall SectionPlan General Notes1. The Contractor is to review the documents andfamiliarize himself with the existing building, its systems,and its structural design and condition before proceedingwith the work2. Refer to Mechanical, Electrical, Plumbing, and FireProtection Drawings for additional information.3. Plans are dimensioned to face of stud, block, or existingconstruction unless otherwise indicated.4. Contractor to field verify all measurements prior tobeginning work. Notify architect immediately of anydiscrepancies.5. Provide and install blocking in walls as required for wallmounted items indicated on drawings.6. Provide soft joints at locations where dissimilarconstruction materials intersect.7. If any information in this set of documents is unclear, itshall be the contractor's responsibility to notify architectfor review. Notify the Architect of any discrepancy in thedrawings as soon as they are discovered. If thecontractor proceeds with any work without giving noticeto the Architect that an error, inconsistency or omissionhas been discovered or could have been discoveredunder careful examination of the drawings, then thecontractor shall bear the costs arising from them.8. Align finishes at joints between new and existing wallsthat appear to be aligned on the plan unless notedotherwise.9. The subcontractor applying the final finish to all floors,walls, and ceilings must accept the condition of thesubstrate prior to applying finishes.10. All construction to meet Americans with Disabilities Act(ADA) requirements for reach and clear floor space - seesheet G-001 for more information.11. All work must meet applicable state and local codes.verify any changes from drawings with architect.12. Loose furniture other than systems furniture to beprovided by Owner and shown for reference only.13. It is the purpose and intent of these drawings that a fullycomplete job be accomplished. It is the contractor'sresponsibility to include all costs and provide labor andmaterials for that portion of the work bid upon, includingincidentals whether or not specifically called for in thedrawings and specifications.14. The architect may at his discretion issue additionaldrawings or instruction indicating greater detail andclarity of work and if reasonably consistent with thepreviously issued documents, the contractor shallperform this work without additional cost or extension ofcontract time.15. In any case where a conflict is detected betweens theplans and the specifications, the contractor shall bebound by the most critical and most fully developedoption. In the event interpretation is needed, theArchitect will render the final decision. The contractor willnot increase his cost or add time to the project schedule.No. Date Description REF.REF.ICETrashElevatorELEV 2ElevatorELEV 1StairSTR 2StairSTR 1S1-4S2-4ELEVELEVOffice434Office433Office432Elevator Lobby401Work Area/Storage423Office430R.R.415R.R.416IT/Elec413Storage414Office412Office411Office410Vault418Office406Office405Office419Office420Office404Office403Office421Office409Office408Office407W.R.R.426M.R.R.427Jan.425Office424IDF428Meeting431Internal Controls435Restroom Corridor429CustomerSolutions422Kitchenette417Accounting/Financial40211' - 6"7' - 1"2' - 1 1/2"11' - 5 1/2"12' - 4 5/8"10' - 4 3/8"11' - 5"1' - 0"34' - 2"18' - 8"34' - 2"1' - 0"11' - 5" VIF10' - 4 3/8" VIF12' - 4 5/8" VIFA5.17Typ at all Offices10'-0" Min Clear1' - 0"13' - 8"10' - 0"1' - 6"EQEQEQEQA5.11VIF5' - 9 3/4"4' - 1"4' - 11"14' - 4"1' - 0"9' - 0"VIF4' - 4 3/4"VIF6' - 0 1/4"3' - 4"4' - 9"5' - 11"4' - 11"6' - 3"2' - 0"10' - 6 3/4" VIF2' - 0"Clear6'-2" MinA5.123' - 9"20' - 0"3' - 9"EQEQ0' - 8"1' - 4"3' - 0"6' - 0"4' - 8"0' - 8"11' - 5"10' - 1 3/4"0' - 8"A5.16A5.16SimClear5'-6" MinA4.11SimA4.21Sim8' - 7"5' - 8"4' - 10"12' - 4"0' - 8"3' - 0"8' - 0"5' - 6"5' - 1"11' - 1"1' - 9"A5.155' - 10"5' - 0"2' - 11"5' - 8"6' - 0 7/8"6' - 2 1/8"A5.14A5.131' - 4"2' - 5"42' - 4"Clear18' - 0" MinX1X1X2X2X3X3X4X4X5X5X6X6X7X7X8X8XAXAXA.4XA.4XBXBXCXCXDXDXEXEXFXFXF.6XF.6XGXGXHXHXIXIXJXJ2A1.4A5.15SimA5.15SimA5.13SimA5.15SimA5.15SimA5.15SimA5.15SimA5.15SimA5.16SimA5.13SimA5.13SimA5.13SimA5.15SimA5.16SimA5.16SimTypUNOTyp at column linesX1 and X8 UNOTyp atperimeterwallA5.12SimA5.17SimA5.17SimA5.17SimA5.17Sim1' - 6"176.46°0' - 9 5/8"A5.17Sim11' - 0 5/8" Fin.11' - 9 1/16" Fin.12' - 5 3/4" Fin.+/- 13' - 2" Fin.1' - 9"8' - 0"22' - 5"20' - 0"8' - 2 7/8"12' - 9 1/8"14' - 0"7' - 0"14' - 0"27' - 6"18' - 0"6' - 6"1' - 9"1' - 9"10' - 0"22' - 2"11' - 4"20' - 0"11' - 4"12' - 2"10' - 0"1' - 9"0' - 10"MICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507ABArea of WorkKey PlanDateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:12 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtA1.4DFourth FloorDimensional PlanDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set" 1/8" = 1'-0"1Fourth Floor Dimension PlanPlan General Notes1. The Contractor is to review the documents andfamiliarize himself with the existing building, its systems,and its structural design and condition before proceedingwith the work2. Refer to Mechanical, Electrical, Plumbing, and FireProtection Drawings for additional information.3. Plans are dimensioned to face of stud, block, or existingconstruction unless otherwise indicated.4. Contractor to field verify all measurements prior tobeginning work. Notify architect immediately of anydiscrepancies.5. Provide and install blocking in walls as required for wallmounted items indicated on drawings.6. Provide soft joints at locations where dissimilarconstruction materials intersect.7. If any information in this set of documents is unclear, itshall be the contractor's responsibility to notify architectfor review. Notify the Architect of any discrepancy in thedrawings as soon as they are discovered. If thecontractor proceeds with any work without giving noticeto the Architect that an error, inconsistency or omissionhas been discovered or could have been discoveredunder careful examination of the drawings, then thecontractor shall bear the costs arising from them.8. Align finishes at joints between new and existing wallsthat appear to be aligned on the plan unless notedotherwise.9. The subcontractor applying the final finish to all floors,walls, and ceilings must accept the condition of thesubstrate prior to applying finishes.10. All construction to meet Americans with Disabilities Act(ADA) requirements for reach and clear floor space - seesheet G-001 for more information.11. All work must meet applicable state and local codes.verify any changes from drawings with architect.12. Loose furniture other than systems furniture to beprovided by Owner and shown for reference only.13. It is the purpose and intent of these drawings that a fullycomplete job be accomplished. It is the contractor'sresponsibility to include all costs and provide labor andmaterials for that portion of the work bid upon, includingincidentals whether or not specifically called for in thedrawings and specifications.14. The architect may at his discretion issue additionaldrawings or instruction indicating greater detail andclarity of work and if reasonably consistent with thepreviously issued documents, the contractor shallperform this work without additional cost or extension ofcontract time.15. In any case where a conflict is detected betweens theplans and the specifications, the contractor shall bebound by the most critical and most fully developedoption. In the event interpretation is needed, theArchitect will render the final decision. The contractor willnot increase his cost or add time to the project schedule.No. Date Description Office434Office433Office432Elevator Lobby401Work Area/Storage423Office430R.R.415R.R.416IT/Elec413Storage414Office412Office411Office410Vault418Office406Office405Office419Office420Office404Office403Office421Office409Office408Office407W.R.R.426M.R.R.427Jan.425Office424IDF428Meeting431Internal Controls435Restroom Corridor429CustomerSolutions422Kitchenette417Accounting/Financial402X1X1X2X2X3X3X4X4X5X5X6X6X7X7X8X8XAXAXA.4XA.4XBXBXCXCXDXDXEXEXFXFXF.6XF.6XGXGXHXHXIXIXJXJArmstrong Axiom Trim, WhiteArmstrong Axiom Trim, WhiteA.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.GWB on Mtl. Stud9' - 6"A.F.F.GWB on Mtl. Stud22' - 0"(From 4th Flr.)A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"A.F.F.2' x 2' ACT9' - 6"15' - 2 1/8"42' - 8 7/8"Bulkhead8'-11"Bulkhead8'-11"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"A.F.F.2' x 2' ACT9' - 0"ExistingExistingOpen to deckOpen to deckCEILING LEGENDExit light - see electricaldrawings, confirm placementwith architect in field. Single ordouble face mount (asrequired)2X4 LED fixture - seeelectrical drawings8" Recessed led downlight -see electrical drawingsSupply diffuser (see HVACplan for sizing)Acoustical ceiling grid, 2'x2' -see finish legend foradditional informationNew gypsum board ceiling orbulkhead finish to level 4 andpaint with PT-1 (see finishlegend) unless noted otherwise2X2 LED fixture - seeelectrical drawingsRecessed linear led fixture -see electrical drawingsReturn/transfer grille (seeHVAC plan for sizing andadditional notes)1X4 LED fixture - seeelectrical drawingsDecorative light fixture - seeelectrical drawingsTrack lighting fixture - seeelectrical drawingsRadiant heat panels (seeHVAC plan for sizing andadditional notes)MICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507ABArea of WorkKey PlanDateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:13 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtA2.4Fourth FloorReflected CeilingPlanDelta FaucetFourth Floor Fit-OutJELJEL10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set" 1/8" = 1'-0"1Fourth Floor Reflected Ceiling PlanNo. Date Description A4.18M.R.R.427W.R.R.426Restroom Corridor429427426967286645316543166821010101010165436X5X6X7XIXJA4.123450GC6B0GF6A0GF6A0OFXA0OFXA0OFXA0GF6A0GC3B0GF6A0OCXA0GC1A0GP3A0OFXA0OFXA0GC1A0GP3A0OFXAA4.21011A4.211A4.29999Verify existing installation prior toinstallation of new walls - installadditional black insulation as directedby architect in field to prevent wallstructures being visable through glass0GP3A0GP3AVerify existing installation prior to installation of new walls -install additional black insulation as directed by architect infield to prevent wall structures being visable through glassFloor drainFloor drainCleanouts, matchfinish to floor drainsCleanout, matchfinish to floor drainsFourth Floor43' - 6"XI7778106153410699WT-3WT-1SS-2PL-7Clear5' - 0"3' - 0"Metal Schluter TransitionSee ADA details2' - 10"Per± 9"Mfg1' - 6"2' - 6"2' - 6"1' - 6"8' - 0"3' - 6"3' - 0"EQEQEQEQSealant joint ot matchgrout color at ceiling -cut tile as requiredFourth Floor43' - 6"XI4261354106106106WT-1WT-13' - 6"3' - 0"3' - 0"0' - 9"Clear5' - 0"EQEQSealant joint ot matchgrout color at ceiling -cut tile as requiredMetal Schluter transitionto wrap cornersFourth Floor43' - 6"X678242612' - 2"5' - 0"2' - 6"1' - 6"5' - 0"Per± 9"Mfg9WT-1WT-1?SS-2PL-7PL-7Metal Schluter transitionto wrap cornersSealant joint ot matchgrout color at ceiling -cut tile as requiredSee detail 11/A4.2Fourth Floor43' - 6"X611106Per± 9"Per± 9"5' - 0"5' - 0"WT-1Sealant joint ot matchgrout color at ceiling -cut tile as requiredMfgMfgFourth Floor43' - 6"XI427135466Clear5' - 0"3' - 0"3' - 6"3' - 0"3' - 0"WT-1WT-1Per± 9"Metal Schluter TransitionMfgSealant joint ot matchgrout color at ceiling -cut tile as requiredFourth Floor43' - 6"X52427EQEQ8WT-1WT-12' - 2"5' - 0"Metal Schluter TransitionSealant joint ot matchgrout color at ceiling -cut tile as requiredFourth Floor43' - 6"XI28777991' - 6"2' - 6"2' - 6"1' - 6"2' - 0"8' - 0"EQEQEQEQWT-1WT-32' - 2"5' - 0"See ADA details2' - 10"Metal Schluter TransitionSealant joint ot matchgrout color at ceiling -cut tile as requiredPL-7SS-2Fourth Floor43' - 6"X5713WT-1MfgSealant joint ot matchgrout color at ceiling -cut tile as requiredPer± 9"SS-2PL-7PL-7See detail 11/A4.2MICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507ABArea of WorkKey PlanDateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:15 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtA4.1Enlarged RestroomPlans & ElevationsDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set" 1/2" = 1'-0"1West Restroom Enlarged Plan 1/2" = 1'-0"2W.R.R. (426) North Elelvation 1/2" = 1'-0"4W.R.R. (426) South ElelvationSpecialty Equipment ScheduleKeynote Description Comments1 Restroom Partitions, gapless, see specification 10 21 13for additional information on hardware, clearances, andmounting heightsContinuous brackets2 Welded Frame Mirror - 24"x60"3 36" Grab Bar Mount per ADA requirements4 48" Grab Bar Mount per ADA requirements5 18" Grab Bar Mount per ADA requirements6 Double-Roll Toilet Tissue Dispenser Mount per ADA requirements7 Welded Frame Mirror - 24"x48" Bott. = +40" AFF maximum,Center on sink basin8 Recessed Automatic Roll Towel and Waste Unit9 Surface Mounted Soap Dispenser10 Surface Mounted Sanitary Napkin Disposal 1/2" = 1'-0"3W.R.R. (426) East Elelvation 1/2" = 1'-0"5W.R.R. (426) West Elelvation 1/2" = 1'-0"6M.R.R. (427) North Elelvation 1/2" = 1'-0"7M.R.R. (427) East Elelvation 1/2" = 1'-0"8M.R.R. (427) South Elevation 1/2" = 1'-0"9M.R.R. (427) West ElelvationNo. Date Description Clear5' - 0"Clear4' - 8"1' - 6"Clear5' - 0"Clear4' - 8"1' - 6"1' - 3"1' - 3"2' - 6"EQEQ2' - 6"2' - 0"3' - 0"6' - 5 3/8"0' - 8"5' - 5"3' - 4"6' - 0 1/4"1' - 9 1/8"4' - 3 1/4"2' - 0"1' - 10"65438834656' - 6"1' - 4"0' - 8"R.R.416Accounting/Financial402R.R.415415416X6X6X7X7XBXBA4.29876A4.2543211A4.211A4.299EQEQFloor drainFloor drainFourth Floor43' - 6"5463415WT-1Sealant joint ot matchgrout color at ceiling -cut tile as requiredFourth Floor43' - 6"XB735469See ADA details2' - 10"WT-3WT-1EQEQ2' - 6"SS-2PL-7Metal Schluter TransitionSealant joint ot matchgrout color at ceiling -cut tile as required3' - 6"1' - 6"Fourth Floor43' - 6"87EQEQ9WT-1SS-2PL-7PL-7See ADA details2' - 10"Sealant joint ot matchgrout color at ceiling -cut tile as requiredSee detail 11/A4.2Fourth Floor43' - 6"XB8415EQEQSealant joint ot matchgrout color at ceiling -cut tile as requiredWT-1Fourth Floor43' - 6"536479See ADA details2' - 10"EQEQ2' - 6"WT-3WT-1Metal Schluter TransitionSealant joint ot matchgrout color at ceiling -cut tile as required3' - 6" Min1' - 6"Fourth Floor43' - 6"X65464163Metal Schluterto wrap cornersSealant joint ot matchgrout color at ceiling -cut tile as requiredWT-1WT-1Fourth Floor43' - 6"8416Metal Schluter TransitionSealant joint ot matchgrout color at ceiling -cut tile as requiredWT-1WT-1Fourth Floor43' - 6"X6879EQEQWT-1See ADA Details2' - 10"6' - 6"SS-2PL-7PL-7Sealant joint ot matchgrout color at ceiling -cut tile as requiredSee detail 11/A4.2Fourth Floor43' - 6"X6427426WT-1EQEQSealant joint ot matchgrout color at ceiling -cut tile as required27"7"2' - 10"4"8"2' - 0"9"11"6"Overhang1"Plastic laminatevalanceRemovable plasticlaminate protection panelSolid surfacecountertop withundermount sinkKnee and toeclearance areaMICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507ABArea of WorkKey PlanDateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:20 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtA4.2Enlarged RestroomPlans, Elevations &SectionsDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set"Specialty Equipment ScheduleKeynote Description Comments1 Restroom Partitions, gapless, see specification 10 21 13for additional information on hardware, clearances, andmounting heightsContinuous brackets2 Welded Frame Mirror - 24"x60"3 36" Grab Bar Mount per ADA requirements4 48" Grab Bar Mount per ADA requirements5 18" Grab Bar Mount per ADA requirements6 Double-Roll Toilet Tissue Dispenser Mount per ADA requirements7 Welded Frame Mirror - 24"x48" Bott. = +40" AFF maximum,Center on sink basin8 Recessed Automatic Roll Towel and Waste Unit9 Surface Mounted Soap Dispenser10 Surface Mounted Sanitary Napkin Disposal 1/2" = 1'-0"1North Restrooms Enlarged Plan 1/2" = 1'-0"3R.R. (416) East Elevation 1/2" = 1'-0"2R.R. (416) North Elevation 1/2" = 1'-0"5R.R. (416) West Elevation 1/2" = 1'-0"4R.R. (416) South Elevation 1/2" = 1'-0"6R.R. (416) North Elevation 1/2" = 1'-0"7R.R. (416) East Elevation 1/2" = 1'-0"8R.R. (416) South Elevation 1/2" = 1'-0"9R.R. (416) West Elevation 1/2" = 1'-0"10Corridor Drinking Fountains West Elevation 1" = 1'-0"11Lavatory Installation DetailNo. Date Description REF.REF.ICETrashX6X6X7X7XCXC0GC3B0GF6AA5.12SimA4.32Kitchenette41741734A4.35A4.3?SS-2?PL-1BelowFloor drain below icemachine, see plumbingdrawingsFourth Floor43' - 6"XC3' - 0"1' - 8"7' - 6"2' - 8 1/2"1 1/2"2' - 0"2' - 0"2' - 0"2' - 0"VIF± 1' - 9 5/8"2" Filler± 2' - 6 1/4"8' - 0"1" OverhangB2424B2424B2424SB2424W2412W2412W24122" Filler2' - 0"2' - 0"2' - 0"4174A4.35A4.3SS-2PL-1PL-1PT-1See caseworkspecifications fordoor and drawerhardware. Pulls shallbe Forms+SurfacesHC423 "Mesa", 3.5"width, satin clearaluminum finish (nosubstitutions for pulls)Fourth Floor43' - 6"X6A4.34SimPT-1Equipment By OwnerFourth Floor43' - 6"White melamineon interior and allfaces of shelvesWhite melamine oninterior and all faces ofshelves and drawersAdjustableshelfAdjustableshelf1' - 0"Space3 1/2" Toe3' - 0"1' - 8"2' - 10"7' - 6"1" Overhang2' - 0"1 1/2"2' - 8 1/2"3" Toe SpacePL-1PL-1SS-2Fourth Floor43' - 6"1" Overhang2' - 0"?White melamineon interiorSpace3 1/2" Toe2' - 10"1 1/2"2' - 8 1/2"3" Toe SpacePL-1SS-2MICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507ABArea of WorkKey PlanDateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:22 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtA4.3Enlarged CaseworkPlans, Elevations &SectionsDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set" 1/2" = 1'-0"1Kitchenetter (417) Enlarged Plan 1/2" = 1'-0"2Kitchenette (417) North Elevation 1/2" = 1'-0"3Kitchenette (417) East Elevation 1/2" = 1'-0"4Casework Section 1/2" = 1'-0"5Casework SectionNo. Date Description EQEQ1' - 4" UNOEQEQ1' - 4" UNO0GC1A0GC1A0GC1A0GC1AXXXXXXXX0GC1A0GC1A0GC1A0GC1A1' - 4" UNO0' - 8"0' - 8"1' - 4" UNO2' - 0" UNO2' - 0" UNOAdjust column overalldimensions as requiredto enclose existing piping0' - 8"VariesSee Plan0GC1A0GC1A0GC1AXX0' - 8"0' - 8"1' - 4"Varies VariesVariesXX0GC1A0GC1A0GC1AVIF0' - 8"0' - 8"0' - 8"1' - 4"EQEQ1' - 4" UNOFinish gypsum board to existingwall above and below openingExisting precastand storefront wallFace of wall above andbelow window openingWrap furring aroundcolumn at windowopening. Paint gyp. boardwrap on all sides PT-1unless otherwiseindicated.XX0GC1A0GC1A8"VIF8"VIFEQEQEQEQ1' - 4" UNO1' - 4" UNOFinish gypsum board to existingwall above and below openingExisting precastand storefront wallFace of wall above andbelow window openingWrap furring aroundcolumn at windowopening. Paint gyp. boardwrap on all sides PT-1unless otherwiseindicated.± 1' - 2 3/8"0' - 8"0' - 8"± 1' - 2 3/8"XXAlign face of gypsum withcenterline of existing mullionFace of existinggypsum board aboveand below windowInstall 0.090" alum. brake metalto finish end of wall and tie toexisting mullion - match materialthickness, color and length ofreturns to previous installs at thethird floorFinish gypsum board to existingwall above and below openingExtend wall into window openingExisting precastand storefront wall0GC1A0GC1A0GC1A0GC1AAlign face of gypsum board withedge of mullion if within 1" based onplan dimensions otherwise extendbrake metal to nearest mullionVariesFace of existing gypsum boardabove and below windowXVIF± 1' - 0"Install 0.090" alum. brake metalto finish end of wall and tie toexisting mullion - match materialthickness, color and length ofreturns to previous installs at thethird floor±9" VIFFinish gypsum board to existingwall above and below openingExtend wall intowindow openingExisting precastand storefront wallMICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507DateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:25 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtA5.1Plan DetailsDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set" 1" = 1'-0"1Plan Detail 1" = 1'-0"2Plan Detail 1" = 1'-0"3Plan Detail 1" = 1'-0"4Plan Detail 1" = 1'-0"5Plan Detail 1" = 1'-0"6Plan Detail 1" = 1'-0"7Plan DetailNo. Date Description MICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507DateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:26 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtA6.1Room FinishSchedule & LegendDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set"Finish LegendCode Material DescriptionManufacturer Style/Color Name/Number CommentsCeiling MaterialsACT-1 ACOUSTICALCEILINGNot UsedACT-2 ACOUSTICALCEILINGACOUSTICAL CEILING TILE ARMSTRONG DUNE - 24X24 - SQUARE LAY-IN (15/16") WHITE w/ AXIOM TRIM IN SPECIFIC LOCATION - SEE PLANSACT-3 ACOUSTICALCEILINGNot UsedACT-4 ACOUSTICALCEILINGNot UsedACT-5 ACOUSTICALCEILINGNot UsedACT-6 ACOUSTICALCEILINGNot UsedACT-7 ACOUSTICALCEILINGNot UsedFloor MaterialsCPT-1 CARPET TILE Not UsedCPT-2 CARPET TILE Not UsedCPT-3 CARPET TILE MILLIKEN ALLEGORY- STANZA STA133-174 LEXIS USE WITH RB-4; MONOLITHIC INSTALLCPT-4 CARPET TILE MILLIKEN ALLEGORY- BALLAD BLD133-174 LEXIS USE WITH RB-4; MONOLITHIC INSTALLCPT-5 CARPET TILE Not UsedC-1 CONCRETE NO FINISH REQUIREDC-2 CONCRETE Not UsedC-3 CONCRETE Not UsedT-1 FLOOR TILE Not UsedT-1A FLOOR TILE Not UsedT-1B FLOOR TILE Not UsedT-2 FLOOR TILE Not UsedT-3 FLOOR TILE Not UsedT-4 FLOOR TILE Not UsedT-5 FLOOR TILE DALTILE SLATE ATTACHE META DARK GRAY SA07 12"X24", MONOLITHIC INSTALL, USE WITH GR-3T-6 FLOOR TILE Not UsedT-7 FLOOR TILE Not UsedT-8 FLOOR TILE Not UsedGR-1 GROUT MAPEI KERACOLOR S 00 WHITE USE W/ TILE WT-1 & WT-3GR-2 GROUT Not UsedGR-3 GROUT MAPEI FLEXCOLOR CQ 27 SILVER USE W/ TILE T-5GR-4 GROUT Not UsedGR-5 GROUT Not UsedRB-1 RUBBER BASE FORMICA 4" COVE RUBBER BASE 29 MOON ROCKRB-2 RUBBER BASE Not UsedRB-3 RUBBER BASE Not UsedRB-4 RUBBER BASE JOHNSONITE 4" COVE RUBBER BASE 44 DARK BROWNVT-1 VINYL TILE WOOD VINYL PLANK ROPPE NORTHERN TIMBERS 042 VOODOO BEECH 4"x36"WB-1 WALL BASE Not UsedWB-2 WALL BASE Not UsedWB-3 WALL BASE Not UsedWB-4 WALL BASE Not UsedWB-5 WALL BASE NATURAL STONE AND TILE 5TH AVENUE - SQUARE EDGE BLACK CHIC WAVES 3.75"X24"Other MaterialsPL-1 PLASTIC LAMINATE ARBORITE DARK SUGAR CANE W-434 RM KITCHENETTEPL-2 PLASTIC LAMINATE Not Used CHESTNUT WOODLINE 5884-58PL-3 PLASTIC LAMINATE Not Used LANDMARK WOOD 7981K-12PL-4 PLASTIC LAMINATE Not Used WHITE ASH 8841-58PL-5 PLASTIC LAMINATE Not Used EBONY RECON 7997-38PL-6 PLASTIC LAMINATE Not UsedPL-7 PLASTIC LAMINATE FORMICA SORREL CHERRY 5886-43 RESTROOM PARTITIONS, LAV. SKIRT/BRACKETSSS-1 SOLID SURFACE Not UsedSS-2 SOLID SURFACE QUARTZ QUANTRA JADE WHITE 2846SS-3 SOLID SURFACE Not UsedTP-1 TOILET PARTITIONS BOBRICK 2082.67P SERIES SOLID PHENOLIC PL-7 FINISHWall MaterialsPT-1 PAINT BEHR PREMIUM PLUS INTERIOR N360-2 SILVER MARLIN 250-400 SF COVERAGE; GENERAL PAINTPT-2 PAINT BEHR PREMIUM PLUS INTERIOR N360-3 STILL GRAY 250-400 SF COVERAGE; TRIM PAINTPT-3 PAINT Not UsedPT-4 PAINT BEHR PREMIUM PLUS INTERIOR M470-6 PRECIOUS STONE 250-400 SF COVERAGE; ACCENT WALL PAINTPT-5 PAINT BEHR PREMIUM PLUS INTERIOR M470-7 BLUE STREAM 250-400 SF COVERAGE; ACCENT WALL PAINTPT-6 PAINT Not UsedWT-1 WALL TILE DALTILE SLATE ATTACHE META WHITE SA04 12"x24", MONOLITHIC INSTALL, USE WITH GR-1WT-2 WALL TILE Not UsedWT-3 WALL TILE LOUISVILLE TILE ISLAND STONE GLASS STRATOS 4"X8", RUNNING BOND INSTALLATION, USE WITH GR-1WT-4 WALL TILE Not UsedWV-1 WINDOW VINYL VINYL TBD TRANSLUCENT APPLIED VINYL GLASS FILMWHITE TRANSLUCENT 40% OPACITY; SEE DOOR ELEVATIONS FOR SIZEWV-2 WINDOW VINYL VINYL TBD TRANSLUCENT APPLIED VINYL GLASS FILM WHITE TRANSLUCENT 40% OPACITY WITH SOLID WHITE DFC WATERMARKSRoom Finish ScheduleNumber NameWall FinishFloor Finish Base FinishCeilingFinishPerimeter Area CommentsNorth East South WestFourth Floor401 Elevator Lobby PT-1 PT-1 PT-1 PT-1 / PT-4 CPT-4 RB-4 ACT-2 56' - 9 3/4" 165 SF402 Accounting/ Financial PT-1 PT-1 PT-1 PT-1 CPT-4 RB-4 ACT-2 496' - 8 1/2" 5209 SF See finish plan for accent wall locations403 Office PT-1 PT-4 PT-1 PT-1 CPT-3 RB-4 ACT-2 48' - 4 1/2" 144 SF404 Office PT-1 PT-1 PT-1 PT-4 CPT-3 RB-4 ACT-2 48' - 4 1/2" 142 SF405 Office PT-1 PT-4 PT-1 PT-1 CPT-3 RB-4 ACT-2 48' - 4 1/2" 144 SF406 Office PT-1 PT-1 PT-1 PT-4 CPT-3 RB-4 ACT-2 51' - 7" 142 SF407 Office PT-5 PT-1 PT-1 PT-1 CPT-3 RB-4 ACT-2 51' - 9 1/4" 167 SF408 Office PT-1 PT-1 PT-5 PT-1 CPT-3 RB-4 ACT-2 48' - 8" 145 SF409 Office PT-1 PT-1 PT-5 PT-1 CPT-3 RB-4 ACT-2 54' - 9" 167 SF410 Office PT-5 PT-1 PT-1 PT-1 CPT-3 RB-4 ACT-2 55' - 10 1/2" 175 SF411 Office PT-5 PT-1 PT-1 PT-1 CPT-3 RB-4 ACT-2 50' - 0" 152 SF412 Office PT-1 PT-1 PT-5 PT-1 CPT-3 RB-4 ACT-2 53' - 1" 175 SF413 IT/Elec PT-1 PT-1 PT-1 PT-1 C-1 RB-1 ACT-2 41' - 2" 94 SF414 Storage PT-1 PT-1 PT-1 PT-1 CPT-4 RB-4 ACT-2 36' - 8 3/4" 56 SF415 R.R. WT-1 / WT-3 WT-1 WT-1 WT-1 T-5 -- ACT-2 28' - 6 1/2" 50 SF416 R.R. WT-1 / WT-3 WT-1 WT-1 WT-1 T-5 -- ACT-2 39' - 6" 84 SF417 Kitchenette PT-1 PT-1 PT-1 PT-1 VT-1 RB-4 ACT-2 50' - 0 3/4" 153 SF418 Vault PT-1 PT-1 PT-1 PT-1 CPT-3 RB-4 ACT-2 51' - 7" 142 SF419 Office PT-1 PT-4 PT-1 PT-1 CPT-3 RB-4 ACT-2 48' - 4 1/2" 144 SF420 Office PT-1 PT-1 PT-1 PT-4 CPT-3 RB-4 ACT-2 48' - 4 1/2" 142 SF421 Office PT-1 PT-4 PT-1 PT-1 CPT-3 RB-4 ACT-2 48' - 4 1/2" 144 SF422 Customer Solutions PT-1 PT-1 PT-1 PT-1 / PT-5 CPT-4 RB-4 ACT-2 317' - 2 1/4" 3033 SF See finish plan for accent wall locations423 Work Area/ Storage PT-1 PT-1 PT-1 PT-1 CPT-4 RB-4 ACT-2 82' - 7 1/2" 318 SF424 Office PT-1 PT-1 PT-1 PT-5 CPT-3 RB-4 ACT-2 49' - 6" 145 SF425 Jan. PT-1 PT-1 PT-1 PT-1 C-1 RB-1 ACT-2 20' - 8 1/2" 28 SF426 W.R.R. WT-1 / WT-3 WT-1 WT-1 WT-1 T-5 -- ACT-262' - 0 1/2" 211 SF TP-1 Toilet Partitions427 M.R.R. WT-1 WT-1 WT-1 / WT-3 WT-1 T-5 -- ACT-2 58' - 5 3/4" 166 SF TP-1 Toilet Partitions428 IDF PT-1 PT-1 PT-1 PT-1 C-1 RB-1 ACT-2 34' - 2 1/2" 65 SF429 Restroom Corridor PT-1 PT-1 PT-1 PT-1 CPT-4 RB-4 ACT-2 109' - 2 1/4" 293 SF430 Office PT-1 PT-1 PT-1 PT-4 CPT-3 RB-4 ACT-2 44' - 7" 123 SF431 Meeting PT-1 PT-1 PT-1 PT-4 CPT-3 RB-4 ACT-2 46' - 8" 103 SF432 Office PT-1 PT-1 PT-5 PT-1 CPT-3 RB-4 ACT-2 49' - 5 1/4" 151 SF433 Office PT-5 PT-1 PT-1 PT-1 CPT-3 RB-4 ACT-2 48' - 1 1/2" 143 SF434 Office PT-5 PT-1 PT-1 PT-1 CPT-3 RB-4 ACT-2 46' - 10" 142 SF435 Internal Controls PT-1 PT-1 PT-1 PT-1 CPT-4 RB-4 ACT-2 130' - 7 1/2" 583 SFGrand total13439 SFNo. Date Description REF.REF.ICETrashOffice434Office433Office432Elevator Lobby401Work Area/Storage423Office430R.R.415R.R.416IT/Elec413Storage414Office412Office411Office410Vault418Office406Office405Office419Office420Office404Office403Office421Office409Office408Office407W.R.R.426M.R.R.427Jan.425Office424IDF428Meeting431Internal Controls435Restroom Corridor429CustomerSolutions422Kitchenette417Accounting/Financial402X1X1X2X2X3X3X4X4X5X5X6X6X7X7X8X8XAXAXA.4XA.4XBXBXCXCXDXDXEXEXFXFXF.6XF.6XGXGXHXHXIXIXJXJCPT-3T-5CPT-3CPT-3CPT-3CPT-3T-5CPT-3CPT-4CPT-3CPT-4CPT-3CPT-4CPT-3CPT-4CPT-3CPT-4CPT-3CPT-3CPT-3CPT-3VT-1T-5T-5CPT-4CPT-3CPT-3CPT-3CPT-3CPT-3CPT-3PT-4PT-4PT-4PT-4PT-4PT-4PT-4PT-5PT-5PT-5PT-5PT-4PT-4PT-5PT-5PT-5PT-5PT-5PT-5PT-5PT-5MICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507ABArea of WorkKey PlanDateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:31 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtA6.2Fourth Floor FinishPlanDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set" 1/8" = 1'-0"1Fourth Floor Finish PlanFinish General Notes1 Interior elevations shown on this sheet highlightareas of multiple wall finishes or other heightcoordination areas2 Floor finish to be C-2 unless noted otherwise3 Wall finish to be PT-1 unless noted otherwise4 Install metal Schluter transitions at all changes infloor materialNo. Date Description Finish FloorPer PlanMfrPer7' - 8"MfrPer8' - 0"EQEQEQ±10' - 6 3/4" VIFGL-1GL-1GL-1Butt-glazedverticalmullion5' - 0"0' - 8"WV-22"7' - 0"2"3' - 0"2"Finish FloorPer Plan2"7' - 0"2"6' - 0"2"Finish FloorPer PlanSee ScheduleSee Schedule6"Req'dAs6"See Schedule6"As Req'd12"See ScheduleGL-1WV-15' - 8"3' - 0"MICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507DateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:32 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtA6.3Door and StorefrontSchedules &ElevationsDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set"Door ScheduleDoorNumberLocation Door Data Frame DataHardwareSetsFireRatingCommentsFrom To Door DimensionsDoor MaterialGlassTypeDoorElevationFrame MaterialFrameElevationNumber Room Name Number Room Name Width Height403 402 Accounting/ Financial 403 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -404 402 Accounting/ Financial 404 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -405 402 Accounting/ Financial 405 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -406 402 Accounting/ Financial 406 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -407 402 Accounting/ Financial 407 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -408 402 Accounting/ Financial 408 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -409 402 Accounting/ Financial 409 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -410 402 Accounting/ Financial 410 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -411 402 Accounting/ Financial 411 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -412 402 Accounting/ Financial 412 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -413 402 Accounting/ Financial 413 IT/Elec 3'-0" 7'-0" Qtr. White Oak - DA Hollow Metal FA 44 - Card Reader414 414 Storage 402 Accounting/ Financial 3'-0" (Pair) 7'-0" Qtr. White Oak - DA Hollow Metal FB 30 -415 415 R.R. 402 Accounting/ Financial 3'-0" 7'-0" Qtr. White Oak - DA Hollow Metal FA 04 -416 402 Accounting/ Financial 416 R.R. 3'-0" 7'-0" Qtr. White Oak - DA Hollow Metal FA 04 -418 402 Accounting/ Financial 418 Vault 3'-0" 7'-0" Qtr. White Oak - DA Hollow Metal FA 44 - Card Reader419 422 Customer Solutions 419 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -420 422 Customer Solutions 420 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -421 422 Customer Solutions 421 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -424 422 Customer Solutions 424 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -425 425 Jan. 429 Restroom Corridor 3'-0" 7'-0" Qtr. White Oak - DA Hollow Metal FA 03 -426 426 W.R.R. 429 Restroom Corridor 3'-0" 7'-0" Qtr. White Oak - DA Hollow Metal FA 24 -427 427 M.R.R. 429 Restroom Corridor 3'-0" 7'-0" Qtr. White Oak - DA Hollow Metal FA 24 -428 429 Restroom Corridor 428 IDF 3'-0" 7'-0" Qtr. White Oak - DA Hollow Metal FA 44 - Card Reader430 402 Accounting/ Financial 430 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -431 402 Accounting/ Financial 431 Meeting 3'-0"7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -432 435 Internal Controls 432 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -433 433 Office 435 Internal Controls 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -434 435 Internal Controls 434 Office 3'-0" 7'-0" Qtr. White Oak GL-1 DB Hollow Metal FA 11 -Window & Storefront ScheduleMarkNominalWidthNominalHeightElevation Frame MaterialFireRatingComments417 11' - 0" 7' - 8" WA Aluminum - Butt-glazing with 1/2" max joints filled with clear siliconeand top and bottom aluminum shoe - match existingglass enclosed conference rooms along main corridorsof existing building by Roberts Glass(www.robertsglass.com or 317-542-0693) 1/4" = 1'-0"Storefront WANote:Provided tempered glass for all glass shown in this project and asrequired by Consumer Product Safety Commission or the IndianaBuilding Code. 1/4" = 1'-0"Frame Elevation FA 1/4" = 1'-0"Frame Elevation FB 1/4" = 1'-0"Door Elevation DA 1/4" = 1'-0"Door Elevation DBNo. Date DescriptionNote: See spec section 08 71 00 Door Hardware for hardware sets schedule. REF.REF.ICETrashS3'-6"DOOR WIDTHINTERIOR WIDTH 6'-8"INTERIOR DEPTH 5'-6 1_8"HOISTWAY WIDTH 8'-6"3'-67_8"4'-43_4"71_4"HOISTWAY DEPTH 6'-11"HSCoptional wall CWire rack 48x24 Wire rack 48x24Storage Cabinet 60x20Storage Cabinet 48x20 Storage Cabinet 48x20 Storage Cabinet 48x20ProductRack24x15ProductRack30x24Storage Cabinet 48x20Storage Cabinet 48x20 Storage Cabinet 48x20Storage Cabinet 48x20Storage Cabinet 48x20Storage Cabinet 48x20X1X1X2X2X3X3X4X4X5X5X6X6X7X7X8X8XAXAXA.4XA.4XBXBXCXCXDXDXEXEXFXFXF.6XF.6XGXGXHXHXIXIXJXJPrinter StationPrinter StationPrinter StationPrinter StationTabletopmicrowaveon Owner-provided cartFuture workstations. Provide power/datadrops similar to other locationsPortable objectsby OwnerFiles/LooseStorage by OwnerPortable objectby OwnerPortable objectby OwnerStorage cabinetsby OwnerFiles/LooseStorage by OwnerFiles/LooseStorage by OwnerAFEDCD3"103 1/2"3"34 1/2"34 1/2"34 1/2"28"39 1/2"67 1/2"3"3A6.4Sim34 1/2"3"3"4A6.4Sim5A6.4SimNote:Install glass privacy screen (G) between ajoiningworkstations as shown in detail 6/A642BECDBD54"CBBF54"BBCE54"GFBBBBBBBECCDBAMICHAELF.CONLY R E G ISTEREDARCHITECTREGISTERED INDIANASTATE OFNo.AR00032507DateDrawn By:Checked By:Project Number:Project NameSheet TitleSheet NumberRevisionsSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationArchitura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com8606 Allisonville RoadSuite 270Indianapolis, IN 46250(317) 413-5724200 South Rangeline RoadSuite 213Carmel, IN 46032(317) 573-222210/6/2016 11:52:36 AMC:\Users\joel\Documents\16113 Delta Faucet 4th Floor Arch_JoeL.rvtA6.4Furniture Plan -Fourth FloorDelta FaucetFourth Floor Fit-OutMFCJMG10/03/20161611355 East 111th StreetIndianpolis, IN 46280"100% Bid Set" 1/8" = 1'-0"1Fourth Floor Furniture Plan 1/2" = 1'-0"26' x 9' System Furniture Workstation Plan 1/2" = 1'-0"36' x 9' System Furniture Workstation RearElevation 1/2" = 1'-0"46' x 9' System Furniture Workstation RightElevation 1/2" = 1'-0"56' x 9' System Furniture Workstation LeftElevation 1/2" = 1'-0"66' x 9' System Furniture Workstation IsometricSystem Furniture Notes1 System70 cubicle surround walls2 Sliding desk mounts3 54" tall hpl monolithic panels with 12" marker board topsection4 8 circuit baseline power5 Data ports with divided chase6 Ergonomic work surface with keyboard cut out7 Desktop surface mount power and data ports8 Electric height adjustable frame for work surface (350lbs.Capacity)9 System70 54" personal storage tower (backpack &coat/suit) with castors10 Sit on storage trolley (2 drawer & a-grade fabric 2"cushion) with castors11 Glass privacy screen12 Contact: Vern Samuels (317) 334-8700A 54" Monolithic panelsB 12" Marker board sectionC Work surfaceD Adjustable height frameE 54" personal storage towerF Sit on storageG Glass privacy screenXSpecific Notes:General specifications and manufacturers:Bryton workstation requirements (design basis):No. Date Description HWSHWRCWSCWRCSCRCRSRLHPS(#)HPCLPS(#)LPCPSCCO2STEAM TRAPSYMBOLS LISTHEATING WATER SUPPLYHEATING WATER RETURNCHILLED WATER SUPPLYCHILLED WATER RETURNCONDENSER WATER SUPPLYCONDENSER WATER RETURNCOOLING COIL CONDENSATEREFRIGERANT SUCTIONREFRIGERANT LIQUIDPIPING (FITTINGS, VALVES, AND MISCELLANEOUS)DROPRISETEECAPREDUCERFLOW ARROWPUMP2-WAY CONTROL VALVE3-WAY CONTROL VALVEBUTTERFLY VALVEBALL VALVECHECK VALVECOMBINATION BALANCE/SHUT-OFF VALVESTRAINERUNIONAUTOMATIC AIR VENTMANUAL AIR VENTPRESSURE RELIEF VALVETHERMOMETERMETERFLEXIBLE CONNECTIONHEAT TRACED PIPEPIPE ANCHORPIPE GUIDEDUCTWORKDOUBLE LINE FLEX DUCTSINGLE LINE FLEX DUCTACCESS DOORPRESSURE REDUCING VALVEGRILLE/REGISTERVOLUME DAMPERFIRE DAMPER RECTANGULARDIFFUSERAIR FLOW ARROWCONNECT TO EXISTINGMOTORIZED DAMPER WITH ACCESS DOORORHIGH PRESSURE STEAMHIGH PRESSURE STEAM CONDENSATELOW PRESSURE STEAMLOW PRESSURE STEAM CONDENSATEPUMPED STEAM CONDENSATETERMINAL BOX W/REHEATPRESSURE/TEMPERATURE TEST PLUGVARIABLE FREQUENCY DRIVEWET BULBVFDWBFPIEXHEWTGTCEXHAUSTFINS PER INCHENTERING WATER TEMPERATUREGENERAL TRADES CONTRACTORDNEFFEATDIADBDOWNEFFICIENCYENTERING AIR TEMPERATUREDIAMETERDRY BULBTOTAL STATIC PRESSURETOTAL COOLING CAPACITYTYPICALUNLESS NOTED OTHERWISETSPTYPTCCUNOPRESSURE DROPRETURN AIRSENSIBLE COOLING CAPACITYPDRASCCABBREVIATIONSCOBFPBOBBLDGAAVCLCLEAN OUTBACKFLOW PREVENTORBUILDINGBOTTOM OF BEAMAUTOMATIC AIR VENTCENTER LINEAMBMFRAFFAPDAMBIENTMANUFACTURERABOVE FINISHED FLOORAIR PRESSURE DROPOUTSIDE DIAMETEROUTSIDE AIRNORMALLY CLOSEDNORMALLY OPENNOT TO SCALEOAODNCNONTSINNER DIAMETERLEAVING WATER TEMPERATUREIDLWTN/ANOT APPLICABLEBASBUILDING AUTOMATION SYSTEMPRVPRESSURE REDUCING VALVERELRELIEF AIRWATER PRESSURE DROPWPDWATER GAUGEWGSUPPLY AIRSASTATIC PRESSURESPEGETHYLENE GLYCOLEAEXHAUST AIRLEAVING AIR TEMPERATURELATBODBOTTOM OF DUCT(D)EXISTING TO BE DEMOLISHED(E)EXISTING TO REMAINBOPBOTTOM OF PIPEBOSBOTTOM OF STRUCTUREESPEXTERNAL STATIC PRESSUREDRAIN VALVE WITH HOSE END ADAPTERPRESSUREGAUGE (WITHSTOPCOCK)EXPANSION JOINTPLUG VALVEGATE VALVETRIPLE DUTY VALVE90 DEGREE FITTING(WITH TURNING VANES)THERMOSTAT (MOUNT 60" AFF UNO)MISCELLANEOUS SENSORCO SENSORCO2 SENSOR(A)EXISTING TO BE ABANDONEDORTEMPERATURE SENSORPRESSURE SENSORFLOW SENSORHUMIDISTAT (MOUNT 60" AFF UNO)SUPPLY/O.A./RETURN DUCTRISE (DOUBLE LINE)SUPPLY/O.A./RETURN DUCTDROP (DOUBLE LINE)OREXHAUST/RELIEF DUCT RISE(DOUBLE LINE)EXHAUST/RELIEF DUCT DROP(DOUBLE LINE)ORORORWITHOUT FLEXWITH FLEXSIDEWALL GRILLE/REGISTER/DIFFUSERWITHOUT FLEXWITH FLEXOROREXISTING WORK (VISIBLE)FUTUREEXISTING TO BE DEMOLISHEDLINE STYLESPIPINGNEW WORK (VISIBLE)(F)FUTUREBACKDRAFT DAMPERNEW WORK (HIDDEN)EXISTING WORK (HIDDEN)(R)RELOCATETEMPERATURE CONTROL PANELTCPGLOBE VALVEGENERAL NOTESA.FOR PURPOSES OF CLEARNESS AND LEGIBILITY, DRAWINGSARE ESSENTIALLY DIAGRAMMATIC, ALTHOUGH SIZE ANDLOCATION OF EQUIPMENT ARE SHOWN TO SCALE WHEREVERPOSSIBLE.B.ALL HVAC WORK SHALL BE PERFORMED IN ACCORDANCEWITH LOCAL CODES.C.COORDINATE THE LOCATION OF ALL UTILITY CONNECTIONPOINTS FOR EQUIPMENT WITH OTHER TRADES.D.CHANGES IN HVAC DUCT AND PIPE ELEVATIONS SHALL BEPROVIDED AND SHALL BE COORDINATED WITH DUCTWORK,PLUMBING, FIRE PROTECTION AND ELECTRICAL SYSTEMS.E.PROVIDE TURNING VANES AT ALL MITERED ELBOWS ANDTEES AS WELL AS WHERE SHOWN ON DRAWINGS.F.DUCTWORK DIMENSIONS SHOWN ON DRAWINGS ARE INSIDECLEAR.G.PROVIDE STRAIGHT RUNS OF DUCT AT THE INLET ANDOUTLET OF EQUIPMENT WITH LENGTHS PERMANUFACTURERS RECOMMENDATIONS. INSTALL ANDSUPPORT MECHANICAL EQUIPMENT PER MANUFACTURER'SRECOMMENDATIONS.H.PERFORM A COMPLETE AIR SYSTEM FLOW BALANCE FOR ALLEXISTING & NEW EQUIPMENT THAT IS SHOWN, SCHEDULEDOR OTHERWISE IDENTIFIED, AT THE END OF CONSTRUCTION.I.UPON COMPLETION OF HVAC SYSTEMS, THE HVACCONTRACTOR SHALL INSTRUCT THE OWNER IN THECOMPLETE OPERATION OF THE SYSTEMS.J.HEATING AND COOLING EQUIPMENT SHALL COMPLY WITH UL1995 SECTION 20.8 FOR ENCLOSED WIRING.K.DIFFUSER RUNOUT SIZES SHALL BE THE SAME AS THE INLETSIZE UNLESS OTHERWISE NOTED. SEE FLOOR PLANS FORDIFFUSER INLET SIZES.L.ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITHMANUFACTURER'S RECOMMENDATIONS.M.FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO STARTINGWORK, ON 4th FLOOR.N.PACK SLEEVES AROUND PIPES PASSING THRU FIRE RATEDWALLS AND PARTITIONS TO MAINTAIN THE FIRE OR SMOKERATING OF THAT CONSTRUCTION PER SPECIFICATIONS.O.HEATING CONTRACTOR IS RESPONSIBLE FOR COMPLETEINSTALLATION OF HEATING AND COOLING EQUIPMENT ANDACCESSORIES INCLUDING ALL CONTROLS.P.PROTECT RETURN AIR SYSTEM FROM CONSTRUCTION DUST.Q.WORK PERFORMED IN OCCUPIED AREAS SHALL BECOORDINATED WITH OWNER PRIOR TO COMMENCING WITHWORK.R.ALL BASE BUILDING SYSTEM SHUTDOWNS SHALL BECOORDINATED WITH OWNER A MINIMUM OF 72 BUSINESSHOURS PRIOR TO SHUTDOWNS. SHUTDOWNS INCLUDE, BUTARE NOT INCLUSIVE TO, ALL HEATING AND COOLINGSYSTEMS, CONTROLS, ASSOCIATED POWER, PLUMBING, FIREALARM, AND FIRE PROTECTION SYSTEM.S.PATCH ALL ADJOINING SURFACES AS NEEDED TO MAINTAINFLOOR, CEILINGS, WALLS, AND AREAS TO MATCH EXISTINGCONDITIONS.EMGEXTRUDED METAL GRATE (1/2" x 1/2")FIRE DAMPER ROUNDBDFDSMOKE DAMPERSDNOTE: NOT ALL ABBREVIATIONS MAY BE USED.NOTE: NOT ALL SYMBOLS MAY BE USED.MMFPTMMTHSCOTM0.4MECHANICALGENERALINFORMATIONSHEETG. SANDERSG. SANDERSDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:42 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\M0-4 - MECHANICAL GENERAL INFORMATION SHEET.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 SCALE:4'8'16'0NTTTTTTTTFD1FOURTH FLOOR MECHANICAL DEMOLITION PLAN1/8"=1'-0"AABBCCDDEEFFGGHHIIJJ11223344556677884.3A.4A.4H.81111515223333354446/1446/1448/1822/12 32/1224/12 22/12 50/20CODED NOTES:1.REMOVE CONTROL WIRING AND SPACESENSOR BACK TO EXISTING VAV TERMINALBOX.2.REMOVE AND RELOCATE VAV TERMINAL BOX.REFER TO NEW PLAN FOR LOCATION.COORDINATE WITH E.C.3.EXISTING VAV TERMINAL BOX TO REMAIN.4.REMOVE AND RELOCATE SUPPLY BRANCHDUCTWORK TO VAV TERMINAL BOX ASINDICATED. SEE NEW PLAN FOR RELOCATEDDUCT AND TAP INTO MAIN SUPPLY.5.REMOVE VAV TERMINAL BOX, CONTROLS,AND DUCTWORK FROM MAIN COMPLETE.TURN TERMINAL BOX OVER TO OWNER ANDDELIVER TO OWNERS STORAGE.MD1.4FOURTH FLOORMECHANICALDEMOLITIONPLANG. SANDERSC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:43 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\MD1-4 - FOURTH FLOOR MECHANICAL DEMO PLAN.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.comArea of WorkKey Plan100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 UPAABBCCDDEEFFGGHHIIJJ1122334455667788X3X44.3A.4A.4H.8UPSCALE:1FOURTH FLOOR MECHANICAL PLAN1/8"=1'-0"4'8'16'0NUPAABBCCDDEEFFGGHHIIJJ1122334455667788X3X44.3A.4A.4H.8UP(E)4L4(E)4H1XTB 4-111TTT5555555TTTXTB 4-5XTB 4-6XTB 4-2TB 4-12XTB 4-7XTB 4-8TB 4-15TTB 4-9TB 4-10D1-8"Ø100D1-8"Ø225D1-10"Ø325D1-10"Ø250D1-10"Ø250G2-12x12G2-12x12G2-12x12G2-24x24G2-24x24CUH-2CUH-2G3-24/12250G3-24/1215010x8G2-12x125TTTG2-24x24G2-24x24G2-24x24G2-24x24G2-24x24G2-24x24G2-24x24G2-24x2420x1214x1214x12D1-10"Ø250D1-8"Ø200D1-10"Ø250D1-10"Ø250TB 4-14TD1-8"Ø200D1-10"Ø250D1-8"Ø235D1-8"Ø235D1-8"Ø235D1-8"Ø235D1-8"Ø235D1-8"Ø175TF-96TF-820x12 20x12 20x12 20x12 20x12 20x1210"Ø10"Ø10"Ø88"ØD1-8"Ø26010/10D1-8"Ø225D1-8"Ø225D1-8"Ø225D1-8"Ø225D1-8"Ø225D1-8"Ø225D1-8"Ø225D1-8"Ø225D1-8"Ø225D1-8"Ø220D1-10"Ø250D1-10"Ø25014/1014/128"Ø8"Ø8"Ø8"Ø8"ØTB 4-1114/1010"Ø12/108"Ø10/108"Ø8"ØD1-8"Ø1508"Ø14x6 TYP3D1-8"Ø16033D1-8"Ø160D1-10"Ø250D1-10"Ø250D1-10"Ø250D1-10"Ø25010x412x810x6D1-6"Ø1006"Ø8"ØD1-8"Ø1508"Ø4-10D1-8"Ø2008"Ø12/10G2-12x1212/10D1-8"Ø1504-58"Ø18/108"ØD1-8"Ø2004-6ERP-1ERP-2D1-10"Ø25010"ØERP-3ERP-4ERP-5ERP-6ERP-7D1-8"Ø230D1-8"Ø230D1-8"Ø230D1-8"Ø230D1-8"Ø230G2-24x2416x12 12/12D1-8"Ø2008"ØD1-8"Ø175D1-8"Ø1758"Ø8"ØD1-8"Ø175D1-8"Ø1758"Ø8"ØG2-24x2414x10 10/10D1-8"Ø200D1-6"Ø1008"Ø8"Ø8/86"Ø6"ØD1-6"Ø100D1-6"Ø100D1-6"Ø1006"Ø6"ØG3-6x650G3-6x6506/66/46/44-148"ØD1-8"Ø110D1-8"Ø11510"Ø8"Ø4-15G2-12x128"Ø10"ØD1-8"Ø2008"ØD1-6"Ø100D1-6"Ø100T4-13TB 4-138"Ø10/10D1-6"Ø1006"ØD1-6"Ø808/88"Ø8"Ø8"ØD1-8"Ø145D1-8"Ø200D1-8"Ø145D1-8"Ø145D1-8"Ø1458"Ø8"Ø4-810Ø10"Ø4-210"Ø10Ø10Ø10"ØD1-8"Ø1758"Ø20x12 D1-8"Ø1508"ØG3-10x1030010/66TTF-84-114-9T4-12XTB 4-34-112"Ø12"Ø91010T4-7TF-98"ØT4-16TB 4-1610/1212x10D1-8"Ø160D1-8"Ø1608"Ø8"ØElevatorELEV 2ElevatorELEV 1StairSTR 1StairSTR 2Office434Office433Office432Elevator Lobby401Work Area/Storage423Office430R.R.415R.R.416IT/Elec413Storage414Office412Office411Office410Vault418Office406Office405Office419Office420Office404Office403Office421Office409Office408Office407W.R.R.426M.R.R.427Jan.425Office424IDF428Meeting431Internal Controls435Restroom Corridor429CustomerSolutions422Kitchenette417Accounting/Financial402CUH-1CUH-111117TTFDAABBCCDDEEFFGGHHIIJJ11223344556677884.3A.4A.4H.846/1446/1448/1822/12 32/1224/12 22/12 50/2012121212121212T4-3G3-6x61008/410/8D1-6"Ø100D1-6"Ø506"Ø6"Ø6"ØGENERAL NOTES:A.ALL EXISTING SUPPLY AND RETURN MAINS ARE AT 9'-7"AFF. THIS INFORMATION IS FOR REFERENCE ONLY.FEILD VERIFY.CODED NOTES:1.RELOCATED TERMINAL BOX AND CONTROLS. CONNECTTO DUCTWORK AS SHOWN.2.ROLL SUPPLY DUCT UP AND OVER EXISTING SUPPLYDUCT BETWEEN ROOF FRAMING.3.TRANSFER AIR ACOUSTICAL ELBOW AND GRILLE. SEEDETAIL.4.CONNECT TO EXISTING 8"X10" EXHAUST DUCTWORKAND EXTEND DUCTWORK TO GRILLES AS SHOWN.5.24"X48" ELECTRIC RADIANT CEILING PANELS. PROVIDELINE VOLTAGE THERMOSTAT TO CONTROL MULTIPLEPANELS, AS SHOWN.6.UNDERCUT DOOR 1" FOR EXHAUST MAKE-UP AIR.7.PROVIDE DDC SUB-CONTROL PANEL (20A 120V).PROVIDE ALL REQUIRED WIRES, CABLES CONDUIT, ANDRELAYS REQUIRED FOR A COMPLETE SYSTEM.COORDINATE EXACT REQUIREMENTS WITH THETEMPERATURE CONTROLS CONTRACTOR.8.CONNECT EXHAUST DUCT TO STUBOUT. BOTTOM AT10'-11" A.F.F.9.10x8" EXHAUST RISER UP TO FAN EF-8 ON ROOF.CONNECT DUCT INTO SIDE OF RISER AND EXTEND TOKITCHENETTE AS SHOWN.10.REUSE DUCTWORK FROM DEMOLITION, IF POSSIBLEOR REPLACE WITH NEW.11.LOCATE TRANSFER AIR FAN AT 9"-6" MIN. AFF. FAN TODISCHARGE AIR INTO ADJOINING AIR PLENUM.12.EXISTING SUPPLY AND RETURN DUCTWORK FROMSHELL SPACE DESIGN. CONNECT TO SYSTEM WHEREINDICATED ON PLANS.M1.4FOURTH FLOORMECHANICALPLANM.BILLIGG.SANDERSDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out10/6/2016 9:02 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\M1-4 - FOURTH FLOOR MECHANICAL PLAN.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.comArea of WorkKey Plan100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 ABCDEFGHIJ1234567891012XBXFXHXJXMXNXQXSXUX2X3X4X14.3A.4XAAEF-4EF-5EF-7EF-6EF-8RTU-3RTU-2RTU-1RTU-448/18 CU-1-2CU-B-1OAEAEAOAEAEAOAEAOAEACU-2-1CU-B-2RSRLRLRSRLRSRLRSRF-1SCALE:1ROOF HVAC PLAN1/8"=1'-0"4'8'16'0N12344444444444M2-4ROOF MECHANICALPLANG. SANDERSG. SANDERSDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:43 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\M2-4 - ROOF MECHANICAL PLAN.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.comArea of WorkKey Plan100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724GENERAL NOTES:A.THIS DRAWING SUPPLIED IS FOR REFERENCEONLY, AND MAY BE USED TO GIVECONTRACTOR A LOCATION OF ANY EQUIPMENTTHAT MAY REQUIRE ADJUSTMENT FROMORIGINAL DESIGN.CODED NOTES:1.ADJUST ECM MOTOR ON EXHAUST FAN EF-8FROM 550 CFM TO 950 CFM.2.RTU-4 NOMINAL BLOCK LOAD CFM OF 12,710.ADJUST DRIVE AS NEEDED FOR THE ADDITIONOF VAV TERMINAL BOXES ON 4th FLOORBUILDOUT, TO MAINTAIN DUCTWORK SUPPLYPRESSURE, AND TEMPERATURE.3.ADJUST ECM MOTOR ON EXHAUST FAN EF-7TO OBTAIN 2175 CFM AFTER COMPLETION OFALL CONNECTED DUCTWORK.4.EXISTING EQUIPMENT INSTALLED UNDERORIGINAL CONTRACT. SEE GENERAL NOTETHIS SHEET. TO S.A.OPENINGINSULATEDROUND DUCTSUPPLY AIR DIFFUSER(LAY-IN FRAME)INSULATED NON-METALLIC FLEXIBLECONNECTION (MAX 5 FT.)18" LONG ORANGE MARKER TAPEATTACHED TO DAMPER TOIDENTIFY LOCATIONSECURE FLEXIBLE DUCT TODUCT COLLARS WITH SCREWSAND DRAWBANDS. PROVIDEADDITIONAL DRAWBANDS ANDSEAL FLEX OUTER JACKET TODUCT COLLARSVOLUME DAMPER LOCATIONWHERE DAMPER WOULD BEINACCESSIBLE AT TAKE-OFF,PROVIDE WITH 3" EXTENDEDSHAFT, HANDLE AND COLLARSHEET METAL ELBOW REQUIREDAIR FLOWDAIR FLOW45°DOUBLE LINE DUCT TAP45° LEAD INRECTANGULARMAIN DUCTROUNDMAIN DUCTROUND ORRECTANGULAR BRANCHDUCTROUNDBRANCHDUCT2ØTAP SIZE1/4D BUT NOTLESS THAN 4".2'-0"CEILING PLENUM1" THK. LINEDDUCTWORKLAY-IN CEILINGRETURN GRILLENOTES:1. SEE PLANS FOR SIZES.6" MIN.SUPPORT STRAP ALL FOURCORNERSANCHOR STRAP TOSTRUCTURE ABOVETURNING VANESAIRFLOWSUPPLY45°45°DUCT MAIN1" MIN. ON TOP ANDBOTTOMADJUSTABLEELBOW RINGSDUCT MAIN1" MIN. ON TOP ANDBOTTOM1/4 BRANCH DUCTWIDTH, BUT MIN. 4"EQUAL TO REQ'D BRANCH DUCTDIMENSIONSSEAL ALLAROUNDEQUAL TO REQ'DBRANCH DUCT DIA.SEAL ALLAROUNDT-BAR GRIDRADIANT PANEL, SEEWIRING CONNECTION ABOVESUPPORT WIRE, ANCHORTO STRUCTURE ABOVE(TYP.OF 4)LAY-IN CEILINGFACTORY PROVIDEDHOLD DOWN CLIP WITHMOUNTING HOLE18 GA. SUPPORT WIRE(TYP.OF 4)B.W.G.LINE VOLTAGE THERMOSTATOR SWITCH (20 AMP MAX.)TYP.277 VOLT CONNECTIONEC TO PROVIDE DISCONNECT SWITCH ABOVECEILING FOR RADIANT PANEL CIRCUIT. COORDINATE WITH M.C.NOTE:M5.4MECHANICALDETAILSG. SANDERSG. SANDERSDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:43 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\M5-4 - MECHANICAL DETAILS.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724SCALE:2DETAIL - DIFFUSER MOUNTED SUPPLYN.T.S.SCALE:3DETAIL - RETURN GRILLE SOUND TRAPN.T.S.SCALE:4DETAIL - TYPICAL MITEREDRECTANGULAR ELBOWN.T.S.SCALE:5DETAIL - 2" WG OR LESS STATIC PRESSURECLASS BRANCH TAKE-OFF FITTINGN.T.S.SCALE:1DETAIL - 3" WG OR MORE STATICPRESSURE CLASS DUCT TAPN.T.S.SCALE:6RADIANT CEILING PANEL INSTALLATIONN.T.S. MIN KWEATLATAMPSVOLTSPHCUH-2SEEPLANSAS SHOWN ON PLANSARCHITECTURALSEMI-RECESSED WALLMOUNTED4.86010017.32771QMARKSSAR48071,3,4NOTES:1.PROVIDE ELECTRICAL DISCONNECT.2.3.PROVIDE INTEGRAL THERMOSTAT.CUSTOM COLOR SELECTION BY ARCHITECT.MECHANICAL/ELECTRICAL ROOMS805060NOTCONTROLLEDOFFICE/CONFERENCE ROOMS755070NOTCONTROLLEDLIFE CYCLE ROOM(ROOM HUMIDITY WILL INCREASE ABOVE DESIGN CONDITIONS WHEN LAB EQUIPMENT/DEVICES EMIT HIGHVOLUMES OF HUMID AIR. HIGH HUMIDITY EQUIPMENT WILL BE LOCATED UNDER HOOD)786070NOTCONTROLLEDLABS725070NOTCONTROLLEDIT ROOMS805080NOTCONTROLLEDSTAIRS / VESTIBULESNOTCONDITIONEDNOTCONDITIONED70NOTCONTROLLEDTAGQTYLOCATIONCONFIGURATIONHEATING DATAELECTRICAL DATAMANUFACTURERMODEL NUMBERNOTESINTERIOR DESIGN AREASUMMERWINTERDB (°F)% RELATIVEHUMIDITYDB (°F)% RELATIVEHUMIDITYELECTRIC UNIT HEATER SCHEDULEHVAC DESIGN DATA 91°F DB SUMMER OUTSIDE DESIGN TEMPERATURES: 75°F WB SUMMER -3°F DB WINTERDESIGN ALTITUDE: 807 FT. INDIANAPOLIS, INROOF TOP UNIT SCHEDULE(REFERENCE ONLY)NOTES:1. ADJUST DRIVE TO OBTAIN REVISED CFM LISTED.UNIT DATATAGSERVICEMODELMINIMUMO.A. CFMTOTALCFMFILTEREFFICIENCYHPRPME.A.T. °FD.B.W.B.L.A.T. °FD.B.W.B.EVAPORATOR DATAHEATINGCFMNO. OFSTAGESNO. OFCOMP.COMPRESSOR DATARPMPHASEFULL LOADAMPS EA.RPMREMARKSSUPPLY FAN DATATOTALMBHSENSIBLEMBHREFRIG.FUELTYPEE.A.T. (°F)L.A.T. (°F)HEATING DATANO. OFFANSCONDENSER FAN DATAVOLTSMOCPMCAUNIT ELECTRICAL DATARTU-4FOURTH FLOOR1,91012,7102.63.8720.0899540.8361.6579.165.852.851.44,56055.0-418.6-130.0150.0R410AGAS39.43.344603FULL LOADAMPS EA.HP EA.EXHAUST FAN DATA4.83FLA EA.QTY2EQUIPMENT BASED ON PRICE UNLESS NOTED OTHERWISEAIR DEVICE SCHEDULENOTES:1. DIFFUSER RUN SHALL BE SAME SIZE AS DIFFUSER INLET UNLESS OTHERWISE NOTED.2. 2 SLOTS (3/4"), VERTICAL AND HORIZONTAL PATTERN.3. 4 SLOTS (3/4"), VERTICAL AND HORIZONTAL PATTERN.4. PROVIDE VERTICAL INLET INSULATED PLENUM BOX.UNIT DATATAGMODELFUNCTIONFACESIZEFRAMETYPEMATERIALFINISHDAMPERN.C.MAX.REMARKSD1SPDSUPPLY24X24LAY-INSTEELWHITE-201TAG-NECK SIZECFMINLET SIZEAS SHOWNON PLANSD2SDBI75SUPPLY-SURFACEALUMINUMWHITE-202,4AS SHOWNON PLANSG1720SUPPLYSTEELWHITE-20-AS SHOWNON PLANSDUCTMOUNTEDNECK SIZEPLUS 1.75"G280RETURNALUMINUMWHITE-20-AS SHOWNON PLANSLAY-ING380EXHAUSTALUMINUMWHITE-20-AS SHOWNON PLANSLAY-IN &SURFACENECK SIZEPLUS 1.75"NECK SIZEPLUS 1.75"48P5L050SEE NOTESE.S.P.IN W.G.T.S.P. INW.G.RETURN FAN DATAHPRPME.S.P.IN W.G.T.S.P. INW.G.----14%-100%1EQUIPMENT BASED ON BROAN UNLESS NOTED OTHERWISETRANSFER FAN SCHEDULETF-8IT RM5111801NOTES:1. PROVIDE WITH REMOTE LINE VOLTAGE THERMOSTAT. MOUNT THERMOSTAT 48" AFF. THERMOSTAT TO BE SET TO 85°F.UNIT DATATAGSERVICEMODELCFMSONESREMARKSRPMVOLTSAMPSMOTOR DATA15751200.94.5G4ATGTRANSFERALUMINUMWHITE-20-SURFACEAS SHOWNON PLANSNECK SIZEPLUS 1.75"G5SDGEREXHAUSTALUMINUMWHITE-25-AS SHOWNON PLANSNECK SIZEPLUS 1"DUCTMOUNTEDG660EXHAUSTALUMINUMWHITE-253/4" LOUVER SPACINGAS SHOWNON PLANSNECK SIZEPLUS 1.75"DUCTMOUNTEDCFM-D3SDBI75SUPPLY-SURFACEALUMINUMWHITE-203,4AS SHOWNON PLANSD4SPDSUPPLY24X24LAY-INALUMINUMWHITE-201AS SHOWNON PLANSMBH77UNIT DATATAGSERVICEMODELSIZEPERFORMANCE DATAkWE.A.T. (°F)L.A.T. (°F)VOLTS/PHASEREMARKSCOOLINGCFMMINCFMHEATINGCFMXTB-4-1FOURTH FLOORSHELLLMHS127.555.096.6460/31050477570XTB-4-2XTB-4-3XTB-4-4XTB-4-5XTB-4-6XTB-4-7XTB-4-8FOURTH FLOORSHELL127.555.0460/31500570FOURTH FLOORSHELL127.555.0460/31400570FOURTH FLOORSHELL127.555.01575570FOURTH FLOORSHELL127.555.0460/31400570FOURTH FLOORSHELL127.555.0460/31500570FOURTH FLOORSHELL127.555.0460/31580570FOURTH FLOORSHELLFOURTH FLOORSHELL460/3# STAGESSTAGED ELECTRIC HEATING COILEQUIPMENT BASED ON KRUEGER UNLESS NOTEDOTHERWISETERMINAL BOX SCHEDULE3333333NOTES:1.PROVIDE WITH TOGGLE SWITCH DISCONNECT ON VAV BOX.2.PROVIDE WITH DISCONNECT SWITCH FOR ELECTRIC REHEAT COIL.3.4.PROVIDE WITH PRESSURE INDEPENDENT CONTROLS.PROVIDE STAGED ELECTRIC HEAT.TB-4-9TB-4-10TB-4-11TB-4-12TB-4-13TB-4-14TB-4-15477477477477477477MCAMOP11.31596.611.31596.611.31596.611.31596.611.31596.611.31596.611.315LMHSLMHSLMHSLMHSLMHSLMHSLMHSLMHSLMHSLMHSLMHSLMHSLMHS05070808050505460/3460/3460/3460/3460/3460/3460/355.055.055.055.055.055.055.0OFFICEOFFICEOFFICEOFFICETOILETAREAWORKAREAWORKAREA4.0325300210097.16.0156.5675500225096.19.81510.0900750235097.115.02010.0900750235097.115.0203.5350275210095.25.3153.0250225210097.14.5153.0250225210097.14.515WATTSAMPSVOLTSPHERP-1-7SEEPLANSCEILING MOUNTED7502.72771MARLEYCP7571,2NOTES:1.UNIT PROVIDED SUPPORT STRAPS WITH HANGER EYELETS.2.PROVIDE SUPPORT WIRES FASTENED TO SUPPORT STRAP AND ANCHORED TO STRUCTURE.TAGQTYLOCATIONHEATING DATAELECTRICAL DATAMANUFACTURERMODEL NUMBERNOTESELECTRIC RADIANT HEAT PANEL SCHEDULETF-9IT RM511180115751200.94.5CUH-1SEEPLANSAS SHOWN ON PLANSARCHITECTURALSEMI-RECESSED WALLMOUNTED3.06010010.72771QMARKSSAR48071,3,4TB-4-16LMHS06460/355.0OFFICE5.0500400210095.17.5155.PROVIEXISTING TERMINAL BOX55555551,2,3,41,2,3,41,2,3,41,2,3,41,2,3,41,2,3,41,2,3,41,2,3,4M6.4MECHANICALSCHEDULESG. SANDERSG. SANDERSDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out10/6/2016 9:01 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\M6-4 - MECHANICAL SCHEDULES.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.17.18.19.20.21.22.XYXYZXYXYZATSF,CF,CXYZMXYZXWPDTVUXXPSLIGHTING SYMBOLSPOWER SYMBOLSGENERAL PURPOSE LUMINAIRE: REFER TO LIGHTINGFIXTURE SCHEDULE FOR ADDITIONAL INFORMATIONGENERAL PURPOSE LUMINARIES ON BATTERY UNITSPOWER: REFER TO LIGHTING FIXTURE SCHEDULE FORADDITIONAL INFORMATIONGENERAL PURPOSE DUAL BALLAST LUMINAIRE ONEBALLAST ON BATTERY UNITS: REFER TO LIGHTINGFIXTURE SCHEDULE FOR ADDITIONAL INFORMATIONROUND LUMINAIRE: REFER TO LIGHTING FIXTURESCHEDULE FOR ADDITIONAL INFORMATIONWALL WASHER: REFER TO LIGHTING FIXTURESCHEDULE FOR ADDITIONAL INFORMATIONWALL MOUNTED LUMINAIRE: REFER TO LIGHTINGFIXTURE SCHEDULE FOR ADDITIONAL INFORMATIONWALL MOUNTED DECORATIVE LUMINAIRE: REFER TOLIGHTING FIXTURE SCHEDULE FOR ADDITIONALINFORMATIONWALL MOUNTED FLOOD LIGHT: REFER TO LIGHTINGFIXTURE SCHEDULE FOR ADDITIONAL INFORMATIONTRACK LIGHTINGTRACK LIGHTING HEADREMOTE HEADSTEP LIGHTEMERGENCY LIGHTEXIT SIGNCEILING MOUNTED ILLUMINATED EXIT SIGN WITHDIRECTIONAL ARROWSEMERGENCY DUAL FACE ILLUMINATED EXIT SIGN WITHDIRECTIONAL ARROWSEXIT SIGN WITH INTEGRAL HEADSSWITCH: X=BLANK-SINGLE POLE 20A, TOGGLE;X=3-THREE WAY; X=4-FOUR WAY; X=P-PILOT LIGHT;X=MS-MOMENTARY; X=D-DIMMER; X=LV-LOW VOLTAGE;PHOTOCELLJUNCTION BOX/FLOOR BOXPANELBOARDLIGHTING CONTROL PANELLOW VOLTAGE TRANSFORMER20A DUPLEX RECEPTACLE WITH COVER PLATE:X=TYPE, Y"=NON-STANDARD MOUNTING HEIGHT,Z=SPECIAL DESIGNATION, U=COMBINATIONFLOOR OR CEILING MOUNTED DUPLEX RECEPTACLE:F=FLOOR, C=CEILINGDOUBLE-DUPLEX RECEPTACLE WITH SINGLE COVERPLATESIMPLEX RECEPTACLE WITH COVER PLATEWALL MOUNTED SPECIAL RECEPTACLE: REFER TOPLANS FOR ADDITIONAL INFORMATIONFLOOR OR CEILING MOUNTED SPECIAL RECEPTACLE:F=FLOOR, C=CEILINGREFER TO PLANS FOR ADDITIONAL INFORMATIONSURFACE MOUNTED RACEWAYSTANDARD DISCONNECT SWITCH: X=DISCONNECTSIZE, Y=NUMBER OF POLESSTANDARD FUSED DISCONNECT SWITCH:X=DISCONNECT SIZE, Y=FUSE SIZE, Z=NUMBER OFPOLESMOTOR STARTER: X=STARTER SIZE, Y=NUMBER OFPOLESCOMBINATION MOTOR STARTER/DISCONNECT SWITCH:X=STARTER SIZE, Y=FUSE SIZE, Z=NUMBER OFPOLESMOTOR (BY OTHERS): PROVIDE POWER AS INDICATEDUTILITY METERFRACTIONAL HORSEPOWER MANUAL MOTOR STARTERJUNCTION BOXTRANSFORMERHANDHOLE/POLE BOX: SEE DETAILS FOR ADDITIONALINFORMATIONCONTROL PANELSURGE PROTECTIVE DEVICEPANELBOARDAUTOMATIC TRANSFER SWITCHVARIABLE FREQUENCY DRIVE (BY DIVISION 23)PUSH BUTTONPOWER POLECORD REELGROUND RODDUPLEX RECEPTACLE ON EMERGENCY CIRCUIT WITHCOVER PLATE: X=TYPE, Y"=NON-STANDARD MTGHEIGHT, Z=SPECIAL DESIGNATION, (18" AFF TYPICAL)OCCUPANCY SENSOR: X=ZONEPOKE THROUGH SERVICE FITTING: X=TYPEWEATHER RESISTANT DUPLEX RECEPTACLE, GROUNDFAULT CIRCUIT INTERRUPTING WITH IN-USE COVERGENERAL LIGHTING NOTESGENERAL ELECTRICAL NOTESDUPLEX RECEPTACLE: ABOVE COUNTER ORBACKSPLASH (6" TO CENTER TYPICAL)DUPLEX RECEPTACLE: ABOVE COUNTER ORBACKSPLASH (6" TO CENTER TYPICAL)EXTERIOR WALL MOUNTED LUMINAIRE: REFER TO LIGHTINGFIXTURE SCHEDULE FOR ADDITIONAL INFORMATIONEXTERIOR BLDG. MOUNTED LUMINAIRE: REFER TO LIGHTINGFIXTURE SCHEDULE FOR ADDITIONAL INFORMATIONX=T-TIMER; X=K-KEY; X=MS-MOMENTARY; X=D-DIMMER;X=OC-BUILT-IN OCCUPANCY SENSOR; X=K-KEYPARTITION SENSORX=CS-LIGHTING CONTROL STATION (8 BUTTON)RECEPTACLE WITH DEDICATED CIRCUITNON-SWITCH RECEPTACLE FOR MONITOR. TYPICALLYFAULT CIRCUIT INTERRUPTING WITH IN-USE COVERAND ARCHITECT FOR EXACT LOCATION.USB COMBINATION POWER OUTLET.NOTE: NOT ALL SYMBOLS SHALL BE USED.NOTE: NOT ALL SYMBOLS SHALL BE USED.AFFAFGCKTGFCIHOAKVAKWLTGMCCNCNOPBTYPVWWHWPXFMRØPHASETRANSFORMERWATTHOURWATTVOLTTYPICALPULL BOX OR PUSH BUTTONNORMALLY OPENNORMALLY CLOSEDMOTOR CONTROL CENTERLIGHTING OR LIGHTKILOWATTKILOVOLT AMPEREHORSEPOWERHAND-OFF-AUTOMATICGROUND FAULT CIRCUIT INTERRUPTERDUAL LUGSCIRCUITCIRCUIT BREAKERCONDUITABOVE FINISHED GRADEABOVE FINISHED FLOORUNOUNLESS NOTED OTHERWISESHIELDED, TWISTED PAIRSTPUNSHIELDED, TWISTED PAIRUTPNON-FUSEDNFMAIN DISTRIBUTION PANELMANUAL TRANSFER SWITCHMAIN LUGS ONLYMTSMDPMLOFULL LOAD AMPSISOLATED GROUNDFLAELECTRICAL CONTRACTOREMERGENCYELECTRIC WATER COOLEREWCAMPS INTERRUPTING CAPACITYAMERICAN WIRE GAUGECLOSED CIRCUIT TELEVISIONCCTVAWGAICPOLYVINYL CHLORIDE (PLASTIC PIPE)TIME CLOCKTCPVCPUBLIC ADDRESSPAELECTRONIC BALLASTMETAL HALIDEMHGENERATORGENPWRPOWERRECPTRECEPTACLEIMPEDANCEZCCBDLEBECEMHPIGNOTE: NOT ALL ABBREVIATIONS SHALL BE USED.MCBMAIN CIRCUIT BREAKERINTERMEDIATE METAL CONDUITIMCGCGENERAL TRADES CONTRACTORCONSTRUCTION MANAGERCMALTERNATING CURRENT OR AIR CONDITIONERACWAPWIRELESS ACCESS POINTGGROUNDWEATHERPROOF, NEMA 3R UNLESS NOTED OTHERWISEAMPEREADOUBLE TWIN TUBEDTTHERTZHZMCAMINIMUM CIRCUIT AMPACITYMAXIMUM OVERCURRENT PROTECTIONMOCPTRTTRIPLE TUBEDIRECT CURRENTDCMAIN SWITCHBOARDMSBABBREVIATIONSNACNOTIFICATION APPLIANCE CIRCUITANNUNCIATORANNCFIRE ALARMFAOCCUPANCYOCCBOLTED PRESSURE SWITCHBPSHIGH PRESSURE CONTACT SWITCHHPCELECTRICAL METAL TUBINGEMTINCANDESCENTINCDEXISTING TO BE RELOCATED(R)FUTURE(F)EXISTING TO REMAIN(E)EXISTING TO BE DEMOLISHED(D)EXISTING TO BE ABANDONED(A)BALLAST FACTORBFFEED THROUGH LUGSFTLTERMINAL REHEAT BOXTRBLRALOCKED ROTOR AMPSS/SSTAINLESS STEELPCOSJMJVFDCPSPDHHMPTXHHXKRXWXP,XDPAGING / SOUND SYMBOLSTELECOMMUNICATION SYMBOLSFIRE ALARM SYMBOLSSPEAKER ("X" INDICATES THE ZONE, "Y" INDICATES THE SYSTEM)VOLUME CONTROL STATIONWALL MOUNTED PHONE OUTLET (42" AFF):CEILING OR FLOOR MOUNTED PHONE OUTLET:C=CEILING, F=FLOORWALL MOUNTED DATA OUTLET (18" AFF UNLESS NOTEDOTHERWISE): X=NUMBER OF OUTLETS, A=ABOVE COUNTERFLOOR BOXSURFACE MOUNTED RACEWAYCABLE TRAYEQUIPMENT RACKTELEPHONE TERMINAL BOARD/PLYWOOD BACKBOARD:REFER TO PLANS FOR ACTUAL LENGTHSCEILING OR FLOOR MOUNTED DATA OUTLET:C=CEILING, F=FLOORWALL MOUNTED PHONE/DATA OUTLET (18" AFF, UNLESS (P=PHONE, D=DATA)CEILING OR FLOOR MOUNTED PHONE/DATA OUTLET:C=CEILING, F=FLOORMANUAL PULL STATION (48" TO HANDLE OF DEVICE)HEAT DETECTORDUCT MOUNTED HEAT DETECTORSMOKE DETECTORDUCT MOUNTED SMOKE DETECTORSPEAKER (80" AFF TO BOTTOM OF DEVICE)BELL, 120VWATER FLOW SWITCH: DIVISION 28 TO PROVIDEWATER TAMPER SWITCH: DIVISION 28 TO PROVIDEPIV VALVEFIRE ALARM MODULEREMOTE INDICATOR STATION FOR DUCT SMOKEDETECTOR (60" AFF TO CENTERLINE)FAN SHUT-DOWN RELAYFIRE ALARM ANNUNCIATOR PANELFIRE ALARM CONTROL PANELSPEAKER WITH STROBE (80" AFF TO BOTTOM OF DEVICE)X = WP - WEATHER PROOFHORN (80" AFF TO BOTTOM OF DEVICE)HORN WITH STROBE (80" AFF TO BOTTOM OFDEVICE)STROBE (80" AFF TO BOTTOM OF DEVICE)A.B.C.D.E.F.G.H.NO WIRING DEVICES OR OUTLET BOXES SHALL BE INSTALLED BACK-TO-BACK.I.J.K.L.HORIZONTAL CABLES SHALL NOT EXCEED 295'.M.ALL JACKS AND PATCH PANELS SHALL BE BY THE SAME MANUFACTURER.N.O.P.Q.R.ALL WIRING SHALL BE PLENUM RATED.S.T.U.V.W.X.LABELINGEACH OUTLET AND CABLE SHALL BE LABELED PER THE USER'S STANDARDSDATA OUTLET LABEL FORMAT:TC0X-XYYY XYTCOX:INDICATES THE SERVING TECHNOLOGY CLOSET NUMBEREXAMPLE:TC01 = OUTLET IS SERVED FROM CLOSET TC01XYYY:"X" INDICATES THE ASSOCIATED FLOOR AND "YYY" INDICATES OUTLETNUMBEREXAMPLE:0001 = OUTLET IS IN BASEMENT AND OUTLET NUMBER IS 001XY:"X" INDICATES OUTLET TYPE, "Y" INDICATES JACK NUMBEREXAMPLE:D1 = DATA JACK NUMBER 1V1 = VOICE JACK NUMBER 1LABEL ABBREVIATIONS:A = A/V OUTLETD = DATA OUTLETW = WIRELESS ACCESS POINT OUTLETV = VOICE OUTLETEXAMPLE OUTLET OR CABLE LABEL: TC01-1021-D1/D2 TC01: INDICATED OUTLET IS SERVED FROM CLOSET TC01 1020: INDICATED OUTLET IS LOCATED ON THE FIRST FLOOR AND THE OUTLET IS NUMBER 021 D1/D2/D3: INDICATED OUTLET HAS 3 DATA JACKS, JACKS D1, D2 AND D31EXAMPLE OUTLETN.T.S.GENERAL SYSTEMS NOTESSECURITY SYMBOLSCAMERA ("XXX" INDICATES THE CAMERA LABEL)DURESS BUTTONCARD READERINTERCOMKEY PADPUSH BUTTON FOR DOOR RELEASEDOOR POSITION SENSORCEILING MOUNTED MOTION DETECTORPUSH PLATEPOINT OF CONNECTIONREQUEST TO EXITELECTRIC LOCKPUSH BUTTONCCTV EQUIPMENT RACKKNOX BOXKEY RESETNOTED OTHEWISE), X=NUMBER OF OUTLETS, A=ABOVE COUNTERPOKE THROUGH DEVICE: PROVIDE (1) DUPLEXOUTLET AND (2) CAT6 DATA JACKS, TERMINATEDATA ON PATCH PANEL IN NEAREST IT CLOSET;A=POWER / A/V / DATA, B=POWER / DATAWIRELESS ACCESS POINT WITH CAT6 CABLE TO DATARACK ON SAME FLOORWAPWALL MOUNTED CCTV / SECURITY CAMERA DATA OUTLET WITH CABLECXXXXSMOKE DETECTOR WITH ELEVATOR RECALLNOTE: NOT ALL SYMBOLS MAY BE USED.NOTE: NOT ALL SYMBOLS MAY BE USED.NOTE: NOT ALL SYMBOLS MAY BE USED.NOTE: NOT ALL SYMBOLS MAY BE USED.TC01-1021 D1/D2TC01-1021 D3TC01-1021 D2TC01-1021 D3TC01-1021 D1NOTE: CABLES SHALL BE LABELED ON BOTHENDSFACEPLATEPERMANENT LABEL(TYP.)PERMANENT LABEL(TYP.)2"-6" (TYP.)DATA JACK(TYP.)SVSSBFSTSPVMRIFAAPFACPRSCALE:DBCRICKPPBMDPPPCRXSSJSIT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR (EC) TOCOORDINATE ANY AND ALL INFORMATION OF THIS PROJECT NECESSARY TOSUPPLY AND INSTALL LIGHTING AS REQUIRED AND DESCRIBED ON THE LIGHTFIXTURE SCHEDULE AND SHOWN ON THESE AND THE ARCHITECTURAL PLANSAND IN THE SPECIFICATIONS.THE PROPER TRIM FOR THE VARIOUS CEILING SYSTEMS ON THIS PROJECT,AS DEFINED ON THE REFLECTED CEILING PLANS AND ROOM FINISHSCHEDULES, INCLUDING SLOPE ADAPTERS, CEILING THICKNESS ADAPTERS,DRYWALL FLANGES, PLASTER FRAMES, SIDE SUPPORTS, FRAMES AND ANYOTHER ACCESSORIES.A FIXTURE CATALOG NUMBER SPECIFIED, WHICH INCLUDES A CEILING TYPE,DOES NOT NECESSARILY MEAN THE FIXTURE IS NOT USED IN ANOTHER TYPEOF CEILING. IN ADDITION, CONTRACTOR SHALL VERIFY CEILINGCONSTRUCTION AND THICKNESS. FIXTURE MOUNTING ASSEMBLIES SHALL BEDESIGNED FOR, AND NOT FIELD MODIFIED, THE DESIGNED CEILING TYPE ANDTHICKNESS.ALL TRIM RINGS OF DOWNLIGHTS SHALL BE PAINTED WHITE UNLESSSPECIFICALLY NOTED OTHERWISE.PROVIDE FIXTURES WITH THE CORRECT AND PROPER VOLTAGES. WHEREVOLTAGES ARE ENCRYPTED INTO THE FIXTURE NUMBER, THE FIXTUREMANUFACTURER SHALL VERIFY VOLTAGES AS INDICATED ON SCHEDULE(AFTER LAMPS).ALL LED FIXTURES SHALL CONTAIN AN ON BOARD ELECTRONIC DRIVER WITHFILTERS. SEPARATE DRIVERS WHERE SCHEDULED OF INDICATED.ALL LED DRIVERS SHALL BE DIMMABLE VIA (0-10V) CONTROLLER, ANDOPERATE ON / OFF MODE ALSO WITHOUT ADDITIONAL DEVICES.WHERE A FIXTURE IS INDICATED ON THE DRAWINGS AS MULTIPLE SWITCHED,PROVIDE MULTIPLE BALLASTS OR DRIVERS.ALL FIXTURES THAT ARE DUAL SWITCHED SHALL BE DONE IN SUCH A MANNERTHAT THE FIXTURE IS EVENLY ILLUMINATED WHEN THE FIXTURE IS PARTIALLYSWITCHED. WHERE FIXTURES ARE DUAL SWITCHED WITHIN AN AREA, THEFIXTURES SHALL ALL APPEAR CONSISTENT IN EACH MODE.TANDEM WIRING OF FIXTURES IS NOT ACCEPTABLE.`NL' OR `nl' ADJACENT TO A FIXTURE INDICATES A `NIGHT LIGHT' ORNON-SWITCHED FIXTURE. IF `NL' IS NOT INDICATED, FIXTURES SHALL BESWITCHED.FIXTURES INDICATED `HATCHED' OR `EM' SHALL CONTAIN AN EMERGENCYBATTERY UNIT WHICH SHALL PROVIDE (1) LAMP FULL LUMEN OUTPUT FOR 90MINUTES. THIS BATTERY UNIT SHALL MONITOR AN UNSWITCHED LIGHTINGCIRCUIT SERVING SAME FIXTURE.THE EXACT LOCATIONS OF LIGHT FIXTURES SHALL BE GOVERNED BY THEARCHITECTURAL DRAWINGS. THE ELECTRICAL DRAWINGS SHALL INDICATETHE TYPE AND CIRCUITING INFORMATION OF THE FIXTURES.ANY NECESSARY WIRING FOR NIGHT LIGHTS AND/OR EMERGENCY LIGHTINGSHALL BE PROVIDED.TAKE PARTICULAR CARE TO ASSURE LAMP COLOR RENDERING ANDTEMPERATURE IS CONSISTENT BETWEEN ALL FIXTURES.ALL LINEAR T8, COMPACT T4 AND T5 FLUORESCENT LAMPS SHALL HAVE ACOLOR RENDERING INDEX OF GREATER THAN 80 AND CORRELATED COLORTEMPERATURE OF 4100 DEG. KELVIN. OTHER LAMPS SHALL MATCH, LOOKAND APPEAR THE %%%%%%UALL SAME REGARDLESS OF THE TYPE OFPHOSPHORUS COATINGS OR APPLICATIONS.ALL LAMPS SHALL BE MANUFACTURED BY THE SAME MANUFACTURER, WHICHSHALL BE GENERAL ELECTRIC, PHILIPS, OR SYLVANIA.ALL LAMPS, WHEN POSSIBLE, SHALL BE ENVIRONMENTALLY SAFE. (I.E. PHILIPSALTO BRAND)THE ELECTRICAL CONTRACTORS' BIDS ARE TO INCLUDE THE LIGHTINGMANUFACTURERS SPECIFIED IN THE LIGHT FIXTURE SCHEDULE. ANALTERNATE LIGHTING BID BY OTHER MANUFACTURERS MAY BE CONSIDEREDIF THE PRODUCT IS EQUAL IN APPEARANCE AND PERFORMANCE AND OF THESAME MATERIALS OF THAT WHICH IS SPECIFIED AND THERE IS A DOLLARSAVINGS TO THE OWNER. THE ENGINEER SHALL BE THE FINAL AUTHORITY ASTO WHAT IS EQUAL IN APPEARANCE AND PERFORMANCE AND MATERIALS. ABID MAY BE CONSIDERED INVALID AND/OR UNRESPONSIVE IF IT CONTAINSMATERIAL THAT IS NOT SPECIFIED ON THE LIGHTING FIXTURE SCHEDULE. THEONLY MANUFACTURERS THAT WILL BE CONSIDERED FOR AN ALTERNATELIGHTING BID ARE BY PRE-APPROVAL ONLY.ALL WIRING ABOVE CEILINGS SHALL BE PLENUM RATED.BID PACKAGE INCLUDES AN ALTERNATE BID PACK. THE WORK INDICATED ONTHE BID DRAWINGS REPRESENTS THE ALTERNATE BID. REFER TO "SUMMARYOF PROJECT" FOR BASE BID SCOPE FOR THIS AREA.23. BID PACKAGE INCLUDES AN ALTERNATE BID PACK. THE WORK INDICATED ONTHE BID DRAWINGS REPRESENTS THE ALTERNATE BID. REFER TO "SUMMARYOF PROJECT" FOR BASE BID SCOPE FOR THIS AREA.ALL DRIVERS SHALL BE`T5 & T8' BALLAST(S) SHALL BE <20% THD.1. THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR,MATERIAL, EQUIPMENT, AND CONTRACTORS SERVICES NECESSARY TOCOMPLETE INSTALLATION OF SYSTEMS REQUIRED IN FULL CONFORMITY WITHAPPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL BEFUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCHITEMS FOR A COMPLETE SYSTEM.2. ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE ANDLOCAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS ANDNATIONALLY ACCEPTED CODES AND STANDARDS. THE ELECTRICALCONTRACTOR WILL BEAR ALL COSTS ARISING IN CORRECTING ANYNONCOMPLIANCE WITH THE REQUIREMENTS OF APPLICABLE CODES.3. ELECTRICAL CONTRACTOR TO COORDINATE SPECIAL ELECTRICAL EQUIPMENTREQUIREMENTS OF TENANTS AS SPECIFICALLY INDICATED ON DRAWINGS.VERIFY ACTUAL REQUIREMENTS WITH ENGINEER PRIOR TO INSTALLATION.4. ELECTRICAL CONTRACTOR SHALL COORDINATE ANY ELECTRICAL OR LIGHTINGREQUIREMENTS OF MILLWORK WITH ARCHITECTURAL WOODWORKCONTRACTOR AS NECESSARY.5. ALL DIMENSIONS SHOWN ARE TO CENTERLINE OF OUTLETS OR GROUPS OFOUTLETS UNLESS NOTED OTHERWISE.6. DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER ASREQUIRED TO MINIMIZE SOUND TRANSMISSION.7. ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BEGANGED THEY SHALL BE INSTALLED WITH 1" BETWEEN FACE PLATES.8. PROVIDE BLANK COVER PLATES TO MATCH EXISTING FOR ANY ABANDONEDELECTRICAL OR COMMUNICATIONS BOXES REMAINING IN WALLS TO REMAIN.9. ELECTRICAL CONTRACTOR SHALL VERIFY WORKING CONDITION OF ALL NEWSWITCHES, LIGHT FIXTURES, BALLASTS, EXIT, AND EMERGENCY LIGHTS ANDOUTLETS AND SHALL REPLACE ANY NON-OPERATIONAL UNITS.10. DO NOT SCALE DRAWINGS. ALL DIMENSIONS GIVEN ARE TO BE ADHERED TOUNLESS FIELD CONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAYEXIST WITH NEW CONSTRUCTION MUST BE REVIEWED BY ENGINEER PRIOR TOCONSTRUCTION OF WORK. DO NOT CIRCUMVENT DIMENSIONS BY ATTACHINGRECEPTACLES TO NEAREST STUD.11. ELECTRICAL/DATA OUTLET LOCATIONS TO BE COORDINATED WITH TENANTPRIOR TO ROUGH-IN. ALL LOCATIONS TO BE VERIFIED WITH FURNITUREPLACEMENT.12. ALL EQUIPMENT FEEDERS SHALL INCLUDE A NEUTRAL UNLESS NOTEDOTHERWISE.13. CONTRACTOR SHALL PROVIDE ELECTRICAL CONNNECTIONS TO ALLEQUIPMENT, COORDINATE REQUIREMENTS ACROSS ALL TRADES.ALL WALL AND FLOOR PENETRATIONS AND SLEEVES SHALL BE SEALED TO MAINTAIN THEASSOCIATED RATING OF THE ASSEMBLY. COORDINATE WITH THE ARCHITECTURAL PLANS.CABLES TO ALL OPEN OFFICE CUBICLES SHALL BE LONG WITHOUT ENOUGH INCLUDINGREQUIRED SLACK BELOW CEILING, TO REACH 4' BEYOND EACH CUBICLES FOR END FROMPOINT WHERE CABLE COMES THROUGH WALL/FLOOR INTO SPACE.CABLE TRAY TRANSITIONS ARE SHOWN IN PLAN VIEW BUT MAY NOT INCLUDE ALL REQUIREDFOR FINAL INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR COORDINATING INSTALLATIONWITH OTHER TRADES AND PROVIDING ALL NECESSARY TRANSITIONS.MINIMUM LOCATIONS AND SIZES OF CABLE TRAY AND SLEEVES ARE SHOWN, THECONTRACTOR IS RESPONSIBLE FOR COORDINATING FINAL NUMBER, LOCATION , AND SIZE.ALL TELECOMMUNICATIONS, AV, SECURITY, LV CONTROL, AND FIRE ALARM CABLES ABOVECEILING SHALL BE SUPPORTED VIA J-HOOKS OR CABLE TRAY. DIFFERENT LOW VOLTAGECABLES CAN ALL BE ROUTED IN THE SAME CABLE TRAY BUT MUST BE ORGANIZED PERSYSTEM TYPE AND COLOR. SEE SPECIFICATIONS AND FLOOR PLANS FOR ADDITIONALINFORMATION. REFER TO FIRE ALARM GENERAL NOTES FOR ADDITIONAL REQUIREMENTS.ALL WALL MOUNT DATA JACKS SHALL BE MOUNTED ADJACENT TO AND GROUPED WITH APOWER OUTLET.A MINIMUM OF A 6" CLEARANCE SHALL BE MAINTAINED OVER CABLE TRAY, WITH EXCEPTIONTO UTILITIES CROSSING PERPENDICULAR. UTILITIES CROSSING PERPENDICULAR SHALLMAINTAIN A 2" CLEARANCE OVER CABLE TRAY.CABLE TRAY SHALL BE ALUMINUM, HOT DIPPED GALVANIZED STEEL, OR STAINLESS STEEL.CABLE TRAY SHALL BE SUPPORTED EVERY 6' WITH 1/2" THREADED ROD (MINIMUM). ALLHARDWARE AND PARTS USED SHALL BE STANDARD PRODUCTS FROM THE SAMEMANUFACTURER.ELECTRICAL EQUIPMENT GREATER THAN 5KVA SHALL BE MOUNTED AT LEAST 47" FROM ANYWALL OF THE COMMUNICATIONS ROOMS TO AVOID EMF INTERFERENCE.THE FILL RATION FOR CONDUIT, SLEEVES, AND CABLE TRAY SHALL NOT EXCEED 40%, VERIFYFILL RATIO WITH ACTUAL MATERIAL BEING INSTALLED.PROVIDE SAFETY END CAPS MADE OF PLASTIC OR OTHER SOFT AND RESILIENT MATERIALSFOR INSERTION INTO ENDS OF UNISTRUT AND OTHER APPURTENANCES TO PROTECT USERSAND MAINTENANCE PERSONNEL FROM SHARP EDGES.UNLESS OTHERWISE INDICATED, ALL MOUNTING ELEVATIONS ARE CENTERLINE ELEVATIONS.ALL DEVICES MOUNTED ON EXTERIOR OF BUILDING SHALL BE WEATHERPROOF TYPE.PAINT EXPOSED RACEWAY IN EXPOSED AREAS TO MATCH ARCHITECTURAL FINISH.EQUIPMENT DIMENSIONS INDICATED ARE APPROXIMATE. VERIFY EXACT SIZE WITHMANUFACTURER.THE CONTRACTOR SHALL FURNISH, INSTALL AND SIZE ALL SLEEVES, HOLES, CORES,PATCHING, SLOTS, ANCHORS, BRACKETS, SUPPORTS, J-BOXES, PULL BOXES AND OTHERAPPURTENANCES NECESSARY TO EXECUTE THE CONTRACT DOCUMENTS COMPLETE. PULLBOXES AND J-BOXES SHALL BE PROVIDED TO LIMIT ALL CONDUIT RUNS TO NO MORE THAN150' (90' FOR TELECOM.) OR FOUR 90 DEGREE BENDS BETWEEN BOXES (TWO 90 DEGREEBENDS FOR TELECOM).THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY. REFER TO SPECIFICATIONSFOR ADDITIONAL REQUIREMENTS.REFER TO DRAWINGS AND SPECIFICATIONS OF OTHER TRADES FOR ADDITIONAL WORKREQUIRED IN THE DIVISION 26, 27 & 28 CONTRACT.THE DESIGN DEPICTED ON THESE DRAWINGS IS A SCHEMATIC IN NATURE AND IS INTENDEDTO SUPPLEMENT THE SPECIFICATIONS AND THE REQUIRED WORK IMPLIED BY THE DRAWINGSAND SPECIFICATIONS OF OTHER TRADES. NOT ALL REQUIREMENTS OR SYSTEM DETAILS ARESHOWN ON THESE DRAWINGS. THE DRAWINGS AND SPECIFICATIONS INDICATE ABSOLUTEMINIMUM REQUIREMENTS.L.V.LOW VOLTAGERECEPTACLE AND USB OUTLET, (18" AFF TYPICAL)UYTEMPERATURE CONTROL CABINET OR CONTRACTORTCCTSESPOWER SUPPLYPSSSMSOUND MASKING EMITTER14. CONTRACTOR MAY USE MC CABLE WHERE APPROPRIATE AND WHERE USINGIT DOES NOT VIOLATE LOCAL BUILDING CODES.DISTRIBUTION PANELBOARDDPFIRE ALARM NAC PANELNACE0.4ELECTRICALGENERALINFORMATIOND. JAMESC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:41 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\E0-4 - ELECTRICAL GENERAL INFORMATION.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 SCALE:1FOURTH FLOOR ELECTRICAL DEMOLITION PLAN1/8"=1'-0"4'8'16'0N12111111111111111122222AABBCCDDEEFFGGHHIIJJ11223344556677884.3A.4A.4H.8SSSFSTSC4AC4BC4CCR1111114455555545445556665811011107712CR12(E)4L4(E)4H133913GENERAL NOTES:A.SEE SHEET E0.4 FOR GENERAL NOTES.CODED NOTES:1.EXISTING FIXTURES TO BE REMOVED AND TURNED OVER TOOWNER. APPROXIMATELY (4) OF THESE LIGHT FIXTURES SHALLBE RELOCATED AS PART OF THIS PROJECT. REFER TO NEWWORK FOR NEW LOCATIONS.2.EXISTING LIGHT FIXTURE TO REMAIN.3.EXISTING ELECTRICAL PANELS TO REMAIN.4.EXISTING FIRE ALARM DEVICE TO REMAIN.5.EXISTING FIRE ALARM DEVICE TO BE RELOCATED TO NEWCONSTRUCTION IN THIS SAME AREA.6.EXISTING CAMERA TO BE RELOCATED IN THIS AREA. REFER TONEW WORK FOR NEW LOCATIONS.7.EXISTING LIGHTING CONTROL TO REMAIN. FOR ADDITIONALSCOPE OF WORK REFER TO NEW WORK.8.EXISTING DISCONNECTS TO REMAIN.9.EXISTING TEMPERATURE CONTROL PANEL TO REMAIN.10.EXISTING VAV TERMINAL BOX TO BE DISCONNECTED ANDRELOCATED. SEE POWER AND SYSTEMS PLAN FOR NEWLOCATION.11.EXISTING VAV TERMINAL BOX TO BE REMOVED AND RETURNEDTO OWNER.12.EXISTING CARD READER TO REMAIN.13.EXISTING RACEWAY TO BE RELOCATED/MODIFIED. REFER TONEW WORK FOR NEW LOCATION.ED1.4FOURTH FLOORELECTRICALDEMOLITIONPLAND. JAMESC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:42 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\ED1-4 - FOURTH FLOOR ELECTRICAL DEMO PLAN.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.comArea of WorkKey Plan100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 UPAABBCCDDEEFFGGHHIIJJ1122334455667788X3X44.3A.4A.4H.8UPSCALE:1FOURTH FLOOR LIGHTING PLAN1/8"=1'-0"4'8'16'0NOCOCOCLVRL1RL1SL11SL11RL9SL11SL11RL3RL3RL3RL3RL3RL3RL3SL1SL1SL1RL2 RL2RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL3RL1SL1SL1RL9RL9RL2ARL1RL1RL2RL1X4X4X4X4X4RL1RL1RL1RL3114H2-1NLRL1NLRL1NLRL1RL1NLNLNLNLRL3RL3aaaaaaaaaaaaaaaaaaaaaaaabbbabbbbbbbbbbbbbbbbbbacccccccbaRL1NLRL1NLX4OCRL2NLRL1cRL1cRL1aRL1NLNLRL1aRL1c66666NL6555555555556(E)4L4(E)4H1OCOCRL2RL2RL2RL2RL2RL2RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL1RL2OCRL2RL2OCRL2OCRL2OCRL2RL2OCRL2RL2OCRL2RL2OCRL2RL2OCRL2RL2OCRL2RL2OCRL2RL2OCRL2RL2OCRL2RL2OCRL2X46RL1RL1RL2RL2RL1RL1RL1RL1RL2RL2RL2RL1RL1RL1RL1RL1RL1RL1RL1RL1RL2RL2aRL1RL1RL16RL1bcbcbbdddddddddccccccccccccccefeeeeeeeeccccccbfffffffffffffffffffOCOCRL1RL1RL3SL8 (12')D4H2 -3444L14L24H2 NLRL1bX46X46X45NL6RL1NL6RL1NL6RL1RL1NL522LVRL3LV2OSOSOSOSOSOSOSOSOSOSOSOSOS2LVOSOSOSOSOSOSElevatorELEV 2ElevatorELEV 1StairSTR 1StairSTR 2Office434Office433Office432Elevator Lobby401Work Area/Storage423Office430R.R.415R.R.416IT/Elec413Storage414Office412Office411Office410Vault418Office406Office405Office419Office420Office404Office403Office421Office409Office408Office407W.R.R.426M.R.R.427Jan.425Office424IDF428Meeting431Internal Controls435Restroom Corridor429CustomerSolutions422Kitchenette417Accounting/Financial40277776a b c d e fa b c d e f33X46X46RL9 RL9 RL9SL9SL9SL9SL9 SL9SL9SL8 (12')ccRL1bRL1bcccRL2cc,ee,fe,fa,ba,ba,bca,bc,dc,dc,dccccccca,bGENERAL NOTES:A.ALL LIGHTING CONTROLS SHALL BE LOWVOLTAGE TYPE.B.OCCUPANCY SENSORS: MINIMUM QUANTITIES INDICATED ON PLANS. APPROXIMATE LOCATIONS INDICATED FOR MINIMUM COVERAGE'S. MANUFACTURER SHALLPROVIDE FLOOR PLAN OF ALL SENSORS AND CONTROL DEVICES. ALL OBSTRUCTIONS INCLUDING BUT NOT LIMITED TO WALLS, FURNITURE, ETC. SHALL BE INCLUDED WHEN OCCUPANCY SENSOR LOCATIONS ARE CALCULATED. C. SET LIGHTING CONTROL TO OCCUPANCY MODE FOR RESTROOMS AND COMMON AREAS.D.ALL WALL MOUNTED OCCUPANCY SENSORSSHALL BE COMBINATION OCCUPANCYSENSOR ANDSWITCH / DIMMER HUBBELL - LIGHT HAWK 2.E.BASE BID CIRCUIT NUMBERS ARE INDICATED.PROVIDE RED LINE SHOWING CIRCUIT MODIFICATIONS AS NEEDED TO MEETREQUIREMENTS OF THIS CHANGE.F.ALL FIXTURES ON EMERGENCY CIRCUITSHALL BE LABELED 'CONNECTED TOEMERGENCY CIRCUIT'.CODED NOTES:1.ALL LIGHTING IN STAIRWELL IS EXISTING TOREMAIN. MAINTAIN EXISTING CIRCUITING.2.PROVIDE AND INSTALL LOW VOLTAGE DIMMERSWITCH AT STANDARD MOUNTING HEIGHT FORLIGHTING CONTROL. SEE WIRING DIAGRAM ONSHEET E7.4A FOR MORE INFORMATION.3.SWITCH BANK: PROVIDE (6) 3-WAY TOGGLESWITCHES AND INSTALL AT STANDARD HEIGHT.SWITCHES SHALL CONTROL ALL OPEN OFFICEGENERAL LIGHTING AND SHALL BE WIRED PERDETAIL ON SHEET E7.4A.4.RELOCATED LIGHT FIXTURE.5.CONNECT TO EMERGENCY LIGHTING CIRCUITEM10NC.6.CONNECT TO EMERGENCY LIGHTING CIRCUITEM11NC.7.CONNECT THIS FIXTURE THROUGH ENCLOSEDRELAY. SEE FIXTURE SCHEDULE FOR INFO.E1.4FOURTH FLOORLIGHTING PLAND. JAMESC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out10/6/2016 9:00 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\E1-4 - FOURTH FLOOR LIGHTING PLAN.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.comArea of WorkKey Plan100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 SUPAABBCCDDEEFFGGHHIIJJ11223344556677884.3A.4A.4H.8UPSCALE:1FOURTH FLOOR POWER AND SYSTEMS PLAN1/8"=1'-0"4'8'16'0NJ1J1JJ2E2.4 GFCIGFCIJJ1J1J1GFCI GFCIGFCIGFCIGFCIJ1J11JJ1J1J1J1J13E2.4 AAAAJ14L2-14L2-34L2-5/74L2-9/11/134L2-15/17/194L2-21/23/254L1-1/3/54L1-13/15/174L1-194L1-214L1-274L1-334L2-6GFCI4L2-1014L2-124L2-144L2-204L2-184L2-164L2-224L2-244L1-12J4L2-35/374L2-284L2-274L1-7/9/114L1-254L1-234L1-184L1-8/104L2-304L1-144L1-164L4-324L4-354L4-37WCCC4L4-284L4-304L1-284L2-44L2-23WAPWAPWAPWAPWAPWAPWAPWAPWAP11GFCI SHH4756955597777777745495COPIER64REF+48"GFCI ICE4L4-3438COPIER8PRINTERS8PRINTERS84L2-36SSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSMSSM1313115JJXTB-4-1XTB-4-5XTB-4-6XTB-4-7XTB-4-84H1 -1,3,54H1 -13,15,174H1 -38,40,424H1-14,16,184H1 -20,22,244H1 -2,4,64H1 -8,10,124L4 -204L4 -224H1 -7,9,111616TB 4-12TB 4-15TB 4-9TB 4-10 CUH-2CUH-2TB 4-14TB 4-11ERP-1ERP-2ERP-3ERP-4ERP-5ERP-6ERP-7TB 4-13XTB 4-34H2 -19,21,234H2 -25,27,294H2 -31,33,354H2 -37,39,414H1 -19,21,234H1 -33,35,374H2-204H2-22CUH-14H2-244H1-39TB 4-164H2 -26,28,30CUH-1UUUUUUUUUUUUUElevatorELEV 2ElevatorELEV 1StairSTR 1StairSTR 2Office434Office433Office432Elevator Lobby401Work Area/Storage423Office430R.R.415R.R.416IT/Elec413Storage414Office412Office411Office410Vault418Office406Office405 Office419Office420Office404 Office403Office421Office409Office408Office407W.R.R.426M.R.R.427Jan.425Office424IDF428Meeting431Internal Controls435RR Corr.429CustomerSolutions422Kitchenette417Accounting/Financial402CR2018181818151517XTB 4-2174H2-24H2-44H2-64H2-84H2-104H2-124H2-1419191919191919CR2021CODED NOTES:1.ROUGH-IN FOR FURNITURE CONNECTION TO POWERCIRCUITS. PROVIDE 4" SQUARE BOX WITH FLUSH SINGLEGANG S/S PLATE. FURNITURE WHIP PROVIDED BYFURNITURE SUPPLIER. PROVIDE PROPER SIZE HOLEPUNCH AND LOCKNUTS. MAKE FINAL CONNECTION TOFURNITURE.2.DATA RACK RECEPTACLE.3.MICROWAVE: PROVIDE RECEPTACLE MOUNTED 6" ABOVECOUNTER OR BACK SPLASH ON 120V DEDICATED CIRCUIT.4.RELOCATED DEVICE. REFER TO EXISTING PLAN.5.EXISTING DEVICE. REWORK AS REQUIRED FOR NEWWALL FINISH.6.EXISTING DEVICE TO REMAIN.7.CONFIRM LOCATION WITH OWNER PRIOR TO ROUGH-IN.8.COPIER / PRINTER: PROVIDE RECEPTACLE ON A 120VDEDICATED CIRCUIT FOR EQUIPMENT. IN ADDITION TOTHE STANDARD DATA PORT, PROVIDE PHONE OUTLETAND (2) PAIR, #18 AWG COPPER PHONE LINES DIRECTLYFROM NEAREST TELEPHONE PUNCH DOWN BLOCK.9.PROVIDE ROUGH-IN FOR DEVICE AT THIS LOCATION.DEVICE INSTALLATION BY OTHERS.10.EXISTING CONDUIT STUB-UP THROUGH FLOOR.11.EXISTING DISCONNECTS TO REMAIN.12.POWER CIRCUIT AND DATA CONNECTION TO EXISTINGTEMP CONTROL CABINET ARE EXISTING TO REMAIN ANDSHALL BE MAINTAINED.13.EXISTING CAMERA RELOCATED. EXTEND VIDEO FEEDLINES TO THIS LOCATION.14.TEMP CONTROL CABINET: PROVIDE DATA PORT ANDDEDICATED 120V CIRCUIT. COORDINATE FINAL LOCATIONWITH TCC.15.RACEWAY MOUNTED ABOVE 4TH FLOOR CEILING.16.ROUTE A 120V DEDICATED CIRCUIT TO THIS LOCATIONAFTER COORDINATING WITH THE MECHANICALCONTRACTOR AND THE TEMPERATURE CONTROLSCONTRACTOR. PROVIDE 120V-24V CONTROLTRANSFORMER MOUNTED IN NEMA-1 ENCLOSUREMARKED "TEMPERATURE CONTROLS TRANSFORMER".24V POWER TO ALL HVAC EQUIPMENT PROVIDED BYOTHERS.17.RELOCATE VAV TERMINAL BOX. RE-USE EXISTINGCIRCUIT AS SHOWN. COORDINATE FINAL LOCATION WITHMECHANICAL CONTRACTOR.18.PROVIDE 30A/1P DISCONNECT SWITCH FOR UNIT HEATER.COORDINATE FINAL LOCATION WITH MECHANICALCONTRACTOR.19.PROVIDE TOGGLE DISCONNECT SWITCH MOUNTED TOUNIT. COORDINATE CONNECTION AND LOCATION OF LINEVOLTAGE THERMOSTAT WITH MECHANICALCONTRACTOR.20.EXISTING CARD READER TO REMAIN.21.RELOCATE/MODIFY EXISTING RACEWAY AS SHOWN.SCALE:3ENLARGED IT/ELEC ROOM1/2"=1'-0"SCALE:2ENLARGED IDF ROOM1/2"=1'-0"(E)4L410104L24H2TELECOM GROUNDING BUSIT/ElecIDF4L2-24L2-424L1-324L1-3422CRESTSPSPSTSESCR99SS4L2-32NAC4L2-384L2-33TCCSOUND MASKING11TCC144L4-194L4-394L1TELECOM GROUNDING BUS(E)4H14L4-3612TF-94L1-6TF-84L2-26191944GENERAL NOTES:A.THE CONTRACTOR SHALL RELOCATE THE EXISTING CAMERAS INTHE SPACE SHOWN ON THE DRAWINGS AND EXTEND THECABLING TO THE NEW LOCATIONS.B.THE BUILDING HAS AN EXISTING ACCESS CONTROL SYSTEMTHAT SHALL BE EXTENDED TO THREE DOORS ON THE FOURTHFLOOR. PROVIDE POWER SUPPLIES AND CONNECTIONS TODOOR EQUIPMENT AND CARD READERS AS SHOWN ON THEDRAWING AND CONNECT TO EXISTING SYSTEM IN BUILDING.C.THE BUILDING CONTAINS A NEW FIRE ALARM SYSTEM. THESYSTEM IS EXISTING ON THE FOURTH FLOOR WITH AN EXISTINGNAC PANEL. ALL DEVICES SHALL BE EXTENDED FROM THIS NACPANEL THAT SERVES THE FOURTH FLOOR TO LOCATIONSSHOWN ON THE DRAWING. EXISTING DEVICES ON THE FOURTHFLOOR SHALL BE RELOCATED AS SHOWN ON THE NEW PLANS.SMOKE DETECTORS SHALL BE PLACED IN THE ELECTRICAL ANDIT ROOMS AND IN FRONT OF THE ELEVATORS.D.ALL CUBICLES AND WORKSTATIONS SHALL RECEIVE STATIONJACKS AS SHOWN ON THE DRAWINGS. ALL STATION JACKS SHALLRECEIVE TWO CAT6 CABLES AND JACKS AND WHERE SHOWN.ALL PRINTERS, COPIERS AND FAX MACHINE SHALL GET ONECAT6 CABLE AND JACK AND ONE COPPER LINE AND JACK. ALLDATA AND STATION JACKS SHALL BE INSTALLED ON ONE SIDE OFSTUD WITH POWER RECEPTACLE ON OTHER SIDE OF STUD.E.SOUND MASKING: VOICE ARREST CONTROL MODULE — MODELSVA300. PROVIDE EMITTERS AND CONTROL CABINETS AS SHOWNON DRAWINGS. PROVIDE PLENUM RATED PATCH CABLES WITHRJ45 MODULAR JACKS TO CONNECT ALL UNITS. EMITTER SHALLBE VOICE ARREST CONTROL MODULE — MODEL VASE. DAISYCHAINING OF UNITS IS ONLY ALLOWABLE WITHIN A SINGLE ZONE.COORDINATE FINAL LOCATION WITH INSTALLER.F.RACEWAY: ROUTE DATA CABLES IN 2" FLEXIBLE CONDUIT ALONGKNEE-WALL TO NEAREST ENLARGED COLUMN, THEN RISING UPINSIDE COLUMN TO RACEWAY MOUNTED ABOVE 4TH FLOORCEILING. COORDINATE WITH ARCHITECTURAL DRAWINGS FORLOCATION OF APPROPRIATE ENLARGED COLUMN. FILL RATIONOT TO EXCEED 40%.E2.4FOURTH FLOORPOWER ANDSYSTEMS PLAND. JAMESC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 12:17 PM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\E2-4 - FOURTH FLOOR POWER & SYSTEMS PLAN.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.comArea of WorkKey Plan100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 OUTLET TYPE:WOUTLET TYPE:OUTLET TYPE:EXTEND 2 - CAT6TO CABLESUPPORTSRJ-45 JACK FORDATA (BLUE)RJ-45 JACKFOR DATABLUEBLANK (TYP.)LABELLABELBLANK (TYP.)BLANK (TYP.)EXTEND 6 - CAT6TO CABLESUPPORTSCOPPER LINESFOR VOICE(WHITE)EXTEND 1 - CAT6TO CABLESUPPORTSRJ-45 JACK FORDATA (BLUE)OUTLET TYPE:EXTEND 1 - CAT6TO CABLESUPPORTS TOCCTV APPLIANCEIN DATA RACK.BLANK (TYP.)CNOTE: LOCATION TO BE CONCEALED WHERE PRACTICAL.COORDINATE WITH SECURITY CONTRACTOR FOREXACT LOCATION PRIOR TO ROUGH-IN.RJ-45 JACK FORDATA (BLUE)LABEL(CAMERAADDRESS)LABELLABELRJ-45 JACK FORDATA (GREEN)PHONEMOUNTINGPOST (TYP.)LABELLABELGENERAL NOTES:A.NOT ALL OUTLET TYPES ARE SHOWN. SEE OUTLET KEY BELOW.B.COLOR SCHEME:DATA (WORK STATION) - BLUE JACK, BLUE CABLEPRINTER, FAX MACHINE AND COPIER LOCATIONS SHALL HAVE AN ADDITIONAL (2) PAIRCOPPER CABLE AND PHONE OUTLET IN ADDITION TO DATA STATION OUTLET.(SECURITY, BMS, ETC.) - GREEN JACK, GREEN CABLEVOICE - WHITE JACK, WHITE CABLE (COPPER LINES)C.ALL DATA CABLES SHALL BE 4 PAIR, UNSHIELDED,CATEGORY 6.D.DETAILS SHOWN ABOVE ARE INDICATED WITH CONDUIT STUB-UPS.DEVICE PLATE RING AND OPENED VERTICAL CABLING IN ANAPPROVED ROUGH-IN, INSIDE FINISHED WALLS AND NOT WHERECEILINGS ARE INACCESSIBLE.1111CODED NOTES:1. REFER TO CABLE PATHWAY DETAIL THIS SHEET.NOTES:1.DEVICES SHOWN STACKED ALONGWALLS FALL IN THE ORDER OFLOWEST (CLOSEST TO WALL) TOHIGHEST (FURTHEST FROM WALL).2.HEIGHTS SHOWN ARE TYPICALUNLESS OTHERWISE NOTEDELSEWHERE ON DRAWINGS, SPECSOR IDENTIFIED IN APPLICABLECODES.3.ALL VERTICAL DIMENSIONS SHOWNARE TO CENTER OF THE DEVICE,EXCEPT THE VERTICAL DIMENSIONOF THE F.A. HORN/STROBE DEVICESARE MEASURED TO THE BOTTOM.4.ALL LIGHTING SWITCHES SHALL BEWITHIN 12" OF DOOR FRAME UNLESSSPECIFICALLY SHOWN OUTSIDE OF ADOOR SWING.18"30"32"48"80"F.A. HORN/STROBE DEVICE(ALIGN W/PULL STATION)THERMOSTATLIGHT SWITCHRECEPTACLEDATA OUTLETPULL DOWNFIRE ALARMCLCLSCALE:1WALL DEVICE ORIENTATIONN.T.S.F.A. PULLSTATION DEVICESUPPORT STRUCTURENOTE: FOR STEEL STRUCTURAL SYSTEMCOMBINATION BEAM CLAMP ANDCONDUIT HANGER OR EQUIVALENTNOTE: FOR STEEL STRUCTURAL SYSTEM.OR EQUIVALENTUNISTRUT CHANNELSIZE AS REQUIREDTHREADED RODBEAM CLAMPOR EQUIVALENTSTRUTCLAMPBEAM CLAMPSCALE:5WALL BOX INSTALLATIONN.T.S.SCALE:71-1/2" AND SMALLER CONDUIT SUPPORTN.T.S.SCALE:82" AND LARGER CONDUIT SUPPORTN.T.S.STEEL JOIST OR BEAMSADDITIONAL RODOR WIRE SUPPORT1/FIXTUREADJUSTABLE SUPPORTBRACKET, 2/FIXTURE(ATTACH TO CEILINGCHANNELS)TIE WIRELAY-INCEILINGFIXTURELAY-INCEILINGCHANNELSSCALE:3LAY-IN CEILING EXIST SIGN MOUNTINGN.T.S.STEEL OUTLET BOX - SIZE PERN.E.C. AND SUPPORT RIGIDLYFROM STRUCTURECHAIN HANGER/AIRCRAFT CABLETO STRUCTURE6' MAX LENGTH - 3/8" FLEX CONDUITW/ 3-#14 CONDUCTORSPENDANT MOUNTED FIXTURENOTES:1.SELECT CHAIN LENGTH TOPROVIDE MOUNTING HEIGHT ASREQUIRED ON DRAWINGS.2.PROVIDE TWO CHAIN HANGERSFOR EACH FIXTURE. ADJUST TOHANG FIXTURE LEVEL.SCALE:4SUSPENDED PENDANT FIXTURE INSTALLATIONN.T.S.SCALE:5RECESSED LIGHTING INSTALLATIONN.T.S.CONDUIT CLAMP OREQUIVALENT SIZEAS REQUIRED30"30"3" WIDE PERMANENT PAINTED SAFETYYELLOW STRIPS 10" SPACING, ONDIAGONAL LAYOUT, ON FLOOR IN FRONTAND REAR OF EQUIPMENTWALLREAR ELEC.EQUIP. FRONTELECT.EQUIP.FRONTMIN. TO LENGTHOF EQUIPMENT3" WIDE PERMANENT PAINTEDSAFETY YELLOW STRIPS, 10"SPACING, ON DIAGONAL LAYOUT, ONFLOOR IN FRONT OF EQUIPMENT.SURFACE MOUNTEDEQUIPMENTFREE STANDINGEQUIPMENTMIN. TO LENGTH OF EQUIPMENTNOTES:1. PAINTED AREAS (DENOTING NEC "WORKING CLEARANCE") REQUIRED IN MECHANICAL ROOMS, CLOSETS AND OTHER AREAS AS SHOWN ON THE DRAWINGS OR IN THE AREAS REQUESTED BY THE ENGINEER.2. PAINTED AREAS NOT TO BE PROVIDED IN CORRIDORS, OFFICES, AND FINISHED ROOMS.3. PAINTING TO BE PROVIDED AS SOON AS FLOOR INSTALLATION ALLOWS. AREAS ARE TO BE RE-PAINTED BEFORE OCCUPANCY.4. PAINT SHALL BE GLIDDEN URETHANE GLOSS ENAMEL, #6000 SERIES OR APPROVED EQUAL.5. COMPLY WITH NEC ARTICLE 110.26SCALE:9ELECTRICAL WORKING CLEARANCEN.T.S.NOTES:1. ALL CONDUITS AND SLEEVES NOT TERMINATING IN A JUNCTION BOX SHALL BETERMINATED WITH A PLASTIC CONDUIT BUSHING BY CONTRACTOR PRIOR TO PULLINGCABLE.2. IF "J-HOOKS" ARE SUBSTITUTED FOR CONDUIT, THE FOLLOWING CONDUITS MAY NOT BEELIMINATED.A. THE CONDUIT UP AND TURNED OUT TO ABOVE CEILING LINE FROM BACK BOX WHEREBOX IS SURFACED MOUNTED.B. A CONDUIT STUB FROM ABOVE CEILING LINE IN SAME AREA, THROUGH WALL ANDSECURED TO CABLE TRAY WHERE CEILING IS NOT ACCESSIBLE.C. ALL CONDUIT ENDS SHALL HAVE BUSHINGS AND BE LABELED.3. WHERE DEVICES ARE INSTALLED IN FINISHED AREAS WITH PLASTER WALLS ANDACCESSIBLE CEILINGS, THE ROUGH-IN MAY BE A "RING AND STRING" TYPE OF ROUGH-IN,UNLESS THE ROUGH-IN IS NOTED AS SPARE OR FUTURE IN NATURE. WHERE DEVICES AREINSTALLED, NO RACEWAY NEEDS TO BE INSTALLED UNLESS THE EXCEPTIONS ARE MET.IE: SURFACED MOUNTED, ETC.4. ALL DATA/TELECOM BOXES SHALL BE MIN. 4" SQUARE BOX WITH SINGLE GANG OPENING.PROVIDE MUD RING WHERE APPLICABLE.BACKBOXWALLCABLE TRAYCONDUIT TO BE SECURED TOTHE SIDE OF THE CABLE TRAY.HORIZONTAL CABLINGFINISHED CEILINGNON-ACCESSIBLEMINIMUM 1"CONDUIT WITHPULL STRINGTELECOMMUNICATIONSOUTLETSCALE:2CABLE PATHWAYN.T.S.T-BAR LAY-IN CEILINGSUSPENSION SYSTEM (TYP.)NOTE: DO NOT SUPPORTCONDUIT OR BOX FROMCEILING GRID HANGERSTYPICAL 2'X4' LAY-INRECESSED LIGHTFIXTURE (TYP.)SAFETY CHAIN (OR WIRE 14" GA. MIN) TOSTRUCTURE INSTALLED WITH ONE LINKMORE THAN TAUT LENGTH (TYP.)4' MIN., 6' MAX. LENGTH - 3/8" FLEXCONDUIT W/ 3-#18 CONDUCTORS;FACTORY WIRE INTO FIXTURE (TYP.)CONDUIT (TYP.)STEEL OUTLET BOX- SIZED PER N.E.C. ANDSUPPORTED RIGIDLY FROM STRUCTURE (TYP.).INSTALL NO CLOSER THAN 1'-0" FROM ANY FIXTURE.8' MAX SPACING BETWEEN HANGERS (TYP.)9/32" DIA. STEEL ROD SUSPENSIONFROM BLDG. STRUCTURE WITHIN 3' OFOUTLET BOX (TYPICAL)3' MAX. FROM BOX TO HANGER (TYP.)CONDUIT CLAMP (TYP.)WORKING CLEARANCE42" MINIMUM OR PERNEC TABLE 110-16(a).(PRINTER, COPIER, FAX)(TYPICAL STATION)SCALE:10TELECOMMUNICATIONS OUTLET KEY AND NOTESN.T.S.E5.4AELECTRICALDETAILSD. JAMESC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:42 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\E5-4A - ELECTRICAL DETAILS.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 1469215171718#16KEY TO OPERATECONTROL PANELLOCKABLE COVER24 HOUR STANDBY, 45 MINUTE CONTINUOUSALARM CAPABILITIES, AFTER 3 HOURS NO POWERXPBATTERYSYNCHRONIZATIONMODULE(S) ASREQUIREDFOR ALLSTROBE CIRCUITSFAAP(NOTIFICATION CIRCUITS)SPRINKLER INITIATING LOOP(S)NACSYFACPEXISTING FIRE ALARMCONTROL PANELIN EXISTING BUILDINGEXISTINGELEV.DAC-NETH-NETSECSECWP1035K71181111116131412SURGE16SURGE1319GENERAL NOTES:CC.DEVICE LOOP CIRCUIT (DLC) WIRING SHALL BE 18 AWG TWISTED. IF TOTAL DISTANCE OF LOOP EXCEEDS 5850 FEET, THEN 16 AWG TWISTED IS TO BE USED. THE DLC CIRCUIT SHALL BE NFPASTYLE 4.DD.STROBE CIRCUITS (STR) WIRING SHALL BE 12 AWG TWISTED PAIR. AT ALARM CURRENT LEVEL, THERE SHALL BE NO MORE THAN A 4.0 VOLT DROP AT THE END OF THE CIRCUIT. THE STROBE CIRCUIT SHALL BE NFPA STYLE "Y".EE.SPEAKER CIRCUITS (SPK) WIRING SHALL BE 14 AWG TWISTED PAIR. THE SPEAKER CIRCUIT SHALL BE NFPA STYLE "Y".FF.INITIATING DEVICE CIRCUIT (HTRI) INPUT WIRING SHALL BE 18 AWG TWISTED, SHIELDED PAIR. TERMINAL 5 OF THE HTRI MUST BE CONNECTED TO A KNOWN EARTH GROUND FOR PROPER OPERATION. (IF A GOOD LOCAL EARTH GROUND IS NOT AVAILABLE, CONNECT SHIELD TO TERMINAL 5.)GG. AC POWER FEED FOR ALL FIRE ALARM CONTROL PANELS SHALL BE 120 VAC, 50/60HZ, 20 AMPS DEDICATED. WIRE SHALL BEMINIMUM 12 AWG COPPER.HH. ALL WIRING AND/OR CABLES SHALL BE FIRE ALARM RATED AND PLENUM RATED.II. TEE-TAPPING IS PERMISSIBLE ON THE DLC LOOP ONLY.JJ. MOUNTING HEIGHTS SHALL BE AS A FOLLOWS: SPEAKERS/STROBE 80” A.F.F. OR 6” BELOW CEILING (WHICHEVER IS LOWER) STROBE 80” A.F.F. OR 6” BELOW CEILING (WHICHEVER IS LOWER) MANUAL PULL STATION 48” A.F.F. TO PULLING LEVER.KK. REFER TO DEVICE INSTALLATION SHEETS FOR BACK BOX REQUIREMENTS.LL. ALL FIRE SPRINKLER VALVE TAMPER SWITCHES AND WATER FLOW SWITCHES SHALL BE MONITORED BY THE FIRE ALARM SYSTEM. ALL DUCTS AT EACH RTU OR AIR HANDLING UNIT SHALL HAVE A DUCT SMOKE DETECTOR MONITORED BY THIS SYSTEM AND SHALL HAVE REMOTE MONITOR AND KEYED RESET FUNCTIONS INSIDE THE BUILDING GROUPED TOGETHER IN A CENTRAL LOCATION. REFER TO PLANS FOR LOCATION.MM REMOTE ADDRESSABLE L.E.D'S HAVE THE SAME ADDRESS AS THE DEVICE IT ANNUNCIATES.NN. TAP ALL SPEAKERS AT 1/2 WATT, UNLESS NOTED OTHERWISE ON PLAN SHEETS. SET ALL STROBE CANDELAS AS NOTED ON PLAN SHEETS. ALL DEVICES SHALL BE TESTED WITH AHS. ANY REQUIRED ADJUSTMENTS REQUESTED SHALL BE MADE IE: VOLUME AND INTENSITY TAP CHANGES TO MEET SOUND AND VISUAL RECOMMENDED LEVELS.OO. THE EXISTING FIRE ALARM SYSTEM IS A SIEMENS XLS SYSTEM.THIS EXISTING SYSTEM SHALL REMAIN AS THE HEAD END, MAIN SYSTEM. THE EXISTING COMMUNICATIONS SYSTEM SHALL REMAIN. THE NEW SYSTEM IS AN EXTENSION OF THIS SYSTEM. PROVIDE ALL REQUIRED EXPANSION CARDS, POWER SUPPLIES, PROGRAMMING, ETC FOR A COMPLETE AND OPERABLE SYSTEM.PP. A TRANSPONDER PANEL SHALL BE PLACED IN THE NEW BUILDING AND COMMUNICATE WITH THE EXISTING FACP PANEL. THE NEW TRANSPONDER SHALL HAVE A MICROPHONE, DEVICE LOOP CARDS, AMP, LIVE VOICE MODULES, ETC. AS REQUIRED.QQ. EXISTING OUTSIDE COMMUNICATIONS FROM THE EXISTING FACP SHALL REMAIN AND CONTINUE TO PROVIDE ALL REQUIRED COMMUNICATIONS.RR. THE NEW BUILDING AND THE EXISTING BUILDING SHALL GO INTO ALARM TOGETHER.SS. NAC PANELS SHALL BE PLACED IN THE NEW BUILDING ON EACH FLOOR IN THE WEST ELECTRICAL ROOMS. ALL DEVICES ON EACH RESPECTIVE FLOOR SHALL BE CIRCUITED TO THAT FLOOR'S NAC PANEL.GENERAL NOTES: (CONTINUED)TT. A KNOX BOX SHALL BE INSTALLED AT THE NEW MAIN ENTRANCE.COORDINATE EXACT LOCATION WITH A.H.J AND THE ARCHITECT.UU. ALL SIGNAL DEVICES SHALL GET TWO CIRCUITS. (A STROBE CIRCUIT AND A SPEAKER CIRCUIT)VV. EVERY CIRCUIT ROUTED THROUGH THE NEW BUILDING'S PERIMETER WALL SHALL HAVE A SURGE SUPPRESSION DEVICE.EACH INDIVIDUAL CIRCUIT SHALL GET ITS OWN PROTECTION DEVICE, NO MULTIPLE CIRCUIT TYPE PROTECTION DEVICES WILLBE ALLOWED. EACH PROTECTION DEVICE SHALL BE INSTALLEDIN A SEPARATE ENCLOSURE AND NO CLOSER THAT 6” OF SEPARATION BETWEEN. PROTECTION DEVICES SHALL ALSO BEPROVIDED FOR CIRCUITS ROUTED BETWEEN THE EXISTING BUILDING AND THE NEW BUILDING.WW. CURRENTLY THE ELEVATOR SHAFT IS NOT SPRINKLED. PROVIDE CONDUIT WITH CABLES FOR INITIATING SIGNALS FORFUTURE DEVICES AT SHAFT CEILING FROM TRANSPONDER PANEL. LABEL FUTURE ELEVATOR SHAFT HEAT AND SMOKE DETECTORS.XX. IT IS ANTICIPATED THAT THE ELEVATOR WILL NOT BE A HYDRAULIC TYPE UNIT, BUT A SMOKE DETECTOR SHALL BE INSTALLED ON A DEDICATED CIRCUIT AT THE CONTROL PANEL.YY. PROVIDE SMOKE DETECTION IN ALL ELEVATOR CONTROL CABINETS AND CLOSETS.ZZ. PROVIDE MONITORING MODULES AND RELAYS FOR ALL ELEVATOR SYSTEMS FOR PROPER CONTROL AS REQUIRED BYALL CODES AND LOCAL AUTHORITIES.AB. PROVIDE ALARM CIRCUIT CONNECTION TO 'POWER SHUT OFF' UNIT FOR ELEVATOR.AC. PROVIDE MONITORING MODULES AND CONNECTION TO BOTH THE KITCHEN'S FIRE SUPPRESSION SYSTEMS.AD. PROVIDE CONNECTION TO ALL RTU'S DUCT DETECTORS. (SUPPLY AND RETURN AS REQUIRED.)AE. PROVIDE SHUT DOWN RELAYS AND SIGNAL TO ALL EXHAUST FANCONTROLLERS.AF. PROVIDE RELAYS, SIGNAL AND CONNECTION TO THE DOOR CONTROL AND SECURITY SYSTEM. COORDINATE WITH SYSTEMSREQUIREMENTS.AG. PROVIDE SPEAKER SIGNAL TO ELEVATOR CONTROLLER FOR VOICE ANNUNCIATION INSIDE EACH ELEVATOR CAB.AH. FIRE ALARM SYSTEM IS A VOICE EVACUATION SYSTEM.AI. FIRE ALARM CABLING HORIZONTAL RUNS MAY BE ROUTED IN OPEN AIR. ALL CABLES SHALL BE PLENUM RATED, FIRE ALARM RATED, AND RATED FOR OPEN SYSTEM.AJ. ALL FIRE ALARM DEVICES SHALL BE INSTALLED IN METALLIC ROUGH-IN BOX WITH EMT RATED VERTICALLY TO ABOVE CEILINGLEVEL.AK. ALL CABLES SHALL BE PLENUM RATED.GENERAL NOTES:A. VERIFY EXACT LOCATION OF ALL EQUIPMENT WITH ARCHITECT BEFOREINSTALLATION.B. ALL FIRE ALARM EQUIPMENT SHALL BE INSTALLED PER NFPA 72 AND NATIONAL ELECTRIC CODE STANDARDS, AND ALL LOCAL CODES AND REQUIREMENTS.C. ALL DEVICES SHALL BE FLUSH MOUNTED IN FINISHED AREAS.D. ALL WIRING AND FIELD DEVICES TO BE INSTALLED BY THE ELECTRICALCONTRACTOR UNLESS OTHERWISE NOTED.E. FIRE ALARM CONTROL AND ANCILLARY PANELS (SUB PANELS) TO BE SERVED BY A DEDICATED 120 VAC 20 AMP CIRCUITS.F. DEVICES REQUIRING 120 VAC POWER SHALL HAVE THE 120V CIRCUIT IN ASEPARATE CONDUIT OTHER THAN THAT OF THE 24 VDC FIRE ALARM CABLES.G. INITIATION DEVICES: WIRING FOR ALL ADDRESSABLE DEVICES, SHALL BE18-2 TSP (TWISTED SHIELDED PAIR), MIN. OR LARGER AS REQUIRED BYMANUFACTURER OR VOLTAGE DROP. T-TAPPING IS ALLOWED. T-TAPPINGSHALL BE HELD TO A MINIMUM. T-TAPS SHALL ONLY BE DONE AT A FIREALARM DEVICE AND SHALL HAVE LOCATION NOTED ON SYSTEM INSTALLATION PRINT.H. NOTIFICATION DEVICES: WIRING FOR ALL NOTIFICATION DEVICES SHALL BE14-2 TWISTED PAIR MIN. NO T-TAPPINGI. ALL WIRING TO BE TAGGED AS TO ZONE WITH LOCATION / AREA SERVED.J. ALL FIRE ALARM JUNCTION BOXES SHALL HAVE A RED COVER.K. INSTALL DUCT DETECTORS AS REQUIRED BY NFPA 90, AND LOCAL CODES.L. DUCT DETECTORS TO BE MOUNTED A MINIMUM OF SIX (6) DUCT WIDTHSFROM BENDS OR INLETS TO AVOID AIR TURBULENCE. INSTALLED BY DIV 23,WIRED BY DIV 26.M. MOUNT ALL SMOKE DETECTORS A MINIMUM OF 3' FROM ANY AIR DIFFUSER.N. AREA SMOKE DETECTORS AND PARTITION DETECTORS SHALL BE INSTALLEDPER NFPA REQUIREMENTS.O. MOUNT ALL NOTIFICATION DEVICES (HORN, HORN/STROBES, AND STROBEONLY (HORN OR VOICE)) DEVICES SO THAT THE BOTTOM OF THE DEVICE ISNOT LESS THAN 80" ABOVE THE FINISHED FLOOR OR 6" BELOW CEILINGWHICH EVER IS LOWER. (UNLESS SPECIFICALLY NOTED OTHERWISE)P. MOUNT MANUAL PULL STATIONS AT 48" ABOVE FINISHED FLOOR TO CENTEROR PULL LEVER. ALL DEVICES SHALL BE SINGLE ACTION WITH KEY RESET.Q. MOUNT ALL ADDRESSABLE MONITOR, OR RELAY CONTROL MODULES NOMORE THAN 5' OFF THE FINISHED FLOOR IN MECHANICAL SPACES ONLY.R. ALL SHORTS, OPENS, AND GROUNDS MUST BE REMOVED FROM WIRINGBEFORE 3RD PARTY REQUIRED TESTING BY MANUFACTURER APPROVEDCOMPANY IS CALLED TO PERFORM THE FINAL SYSTEM CONNECTION ANDCHECK-OUT.S. ELEVATOR: PROVIDE CONNECTION TO ELEVATOR CONTROLLER.T. FIRE ALARM SYSTEM IS A VOICE EVACUATION SYSTEM.U. EXISTING BUILDING SYSTEM SHALL BE UPGRADED AS REQUIRED TO EXTENDSYSTEM TO NEW BUILDING AND PROVIDE A FULLY FUNCTIONAL OPERATINGSYSTEM.V. EXISTING SYSTEM IS A SEIMENS SYSTEMS CURRENTLY SERVICES BY KOORSEN.W. ALL FIRE ALARM DEVICES INSIDE STAIRWELL MAY BE SURFACE MOUNTED.X. ALL VERTICAL RUNS IN WALLS OR OUT OF WALLS, SHALL BE ROUTED INCONDUIT TO WITHIN 12" OF DECK ABOVE.Y. CABLES BETWEEN EXISTING PANEL AND NEW PANEL SHALL BE ROUTED INMETALLIC RACEWAY. THE CABLES BETWEEN THE MAIN PANELS, TO THEFAAP, AND NAC PANELS SHALL NOT BE ROUTED FREE AIR, BUT SHALL BEROUTED IN CONDUIT.Z. FIRE ALARM CABLING HORIZONTAL RUNS MAY BE ROUTED IN OPEN AIR. ALLCABLES SHALL BE PLENUM. RATED, AND RATED FOR OPEN SYSTEM PERNFPA 72.AA. ALL RACEWAY ENDS SHALL HAVE NYLON BUSHING. ALL BUSHINGS SHALL BEINSTALLED PRIOR TO PULLING CABLES. BUSHING SHALL NOT BE SPLITTYPE. ALL BUSHINGS SHALL BE TAPED.BB. THE FIRE ALARM SYSTEM IS EXISTING . EXTEND CIRCUITS OUT TO ANDPROVIDE NEW DEVICES ON THIS FLOOR. UTILIZE EXISTING NAC PANEL ONTHIS FLOOR TO SERVE THIS FLOOR.FIRE ALARM RISER NOTES:1. NEW DEDICATED 120VAC. 20AMP CIRCUIT.2. EXISTING 3/4" CONDUIT TO FIRST FLOOR DATA / IT ROOM FOR FUTURE COMMUNICATIONS. FOLLOW MAIN CONDUIT TO TIE THE TWO BUILDINGS TOGETHER TO CONNECTING CORRIDOR.3. ALL INITIATING DEVICES SHALL BE ADDRESSABLE AND SHALL BE WIRED USING 18/2 TSP (TWISTED SHIELDED PAIR) IN CONDUIT. EXAMPLES WOULD BE MANUAL PULL, SMOKE DETECTOR, HEAT DETECTOR, MONITOR MODULES, RELAY MODULES, AND DUCT DETECTORS. T-TAPPING OF INITIATION CIRCUITS IS ALLOWED ONLY IF APPROVED BY APPROVED MANUFACTURE4. ALL NOTIFICATION DEVICES SHALL BE WIRED PER MANUFACTURER'S REQUIREMENTS. EXAMPLES WOULD BE HORNS, BELLS, STROBES, AND HORN STROBES. NO T-TAPPING OF NOTIFICATION CIRCUITS IS ALLOWED . DO NOT EXCEED NOTIFICATION LOOP LOAD.5. EXISTING ADDRESSABLE MONITOR OR RELAY CONTROL MODULES TO BE MOUNTED WHERETHEY ARE ACCESSIBLE WITHOUT THE USE OF A LADDER AND IN SERVICE / MECHANICAL / ELECTRICAL SPACES ONLY. THESE MODULES ARE TYPICALLY CONNECTED TO ELEVATOR CONTROL PANELS AND BUILDING SPRINKLER DEVICES AND SHOULD BE PLACED SO AS NOTTO ALLOW CONTACT WITH WATER. CONTRACTOR SHALL COORDINATE INSTALLATION LOCATIONS WITH AREA USE.6. ALL NOTIFICATION DEVICES SHALL BE WIRED PER MANUFACTURER'S REQUIREMENTS.7. MANUAL PULL STATIONS SHOULD BE LOCATED AS REQUIRED BY A.H.J. PROVIDE IN BID FOR (2) ADDITIONAL DEVICES FOR ALL BUILDINGS WHERE MORE THAN (8) MANUAL STATIONS ARE INDICATED ON THE PLANS.8. EXISTING FACP (FIRE ALARM OR TRANSPONDER PANEL,CONTROL PANEL) (XP PANEL) TO BELOCATED AS SHOWN ON PLANS WITH TOP OF CABINET NO MORE THAN 60' ABOVE FINISHEDFLOOR. A SMOKE DETECTOR SHALL BE LOCATED DIRECTLY ABOVE ALL FIRE ALARM PANELS.9. EXISTING NAC (NOTIFICATION APPLIANCE CIRCUIT EXTENDER) DEDICATED 120VAC 20AMP CIRCUIT. SHOULD BE LOCATED WITH TOP OF CABINET 60" ABOVE FINISHED FLOOR (UNLESS INDICATED OTHERWISE), AND LOCATED IN CONCEALED NON-PUBLIC AREAS. CONTRACTOR SHALL PROVIDE ALL NAC PANELS REQUIRED FOR COMPLETE OPERATIONALINSTALLATION. THE NUMBER OF REQUIRED PANELS SHALL BE BASED ON 80% LOADING OFMANUFACTURES SUGGESTED LOADING. A SMOKE DETECTOR SHALL BE LOCATED DIRECTLY ABOVE.10. EXISTING FAAP (FIRE ALARM ANNUNCIATOR PANEL) HOME RUN (1) 18/2 TSP (TWISTED SHIELDED PAIR) AND (1) 14/2 TWISTED PAIR TO FACP (FIRE ALARM CONTROL PANEL) IN CONDUIT. COORDINATE WITH MANUFACTURER FOR CONNECTION POINT(S). ROUTE TO MAIN PANEL IF REQUIRED. FLUSH MOUNT PANEL ONLY.11. LOCATION OF EQUIPMENT TO BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION AND ROUGH-IN.12. EXISTING SIEMENS PANEL. PROVIDE UPGRADE CARD(S) TO EXTEND TO AND SUPPORT NEW TRANSPONDER PANEL. 14/2 TWISTED PAIR TO FACP (FIRE ALARM CONTROL PANEL) IN CONDUIT. COORDINATE WITH MANUFACTURER FOR CONNECTION POINT. ROUTE TO MAIN PANEL IF REQUIRED. DAC-NET: TWO PAIRS 18 AWG TWISTED. H-NET: ONE PAIR 18 AWG TWISTED, SHIELDED. EXTEND FROM EXISTING PANEL TO NEW PANEL IN 3/4" CONDUIT.13. CABLE AS REQUIRED BY MANUFACTURER. PROVIDE SPARE CABLE INSIDE SAME RACEWAY.COIL ENDS INSIDE EACH PANEL AT EACH END.14. EXISTING ROUTE CABLE FOR FOURTH FLOOR 'NAC' PANEL LEAVING AMPLE SLACK FOR RELOCATION.15. EXISTING PROVIDE COMMUNICATIONS TO AND FROM EACH ELEVATOR CONTROL PANEL. PROVIDE MONITORING/ CONTROL MODULES AS REQUIRED. ALSO PROVIDE SIGNAL TO SHUNT TRIP POWER BREAKERS SUPPLYING ELEVATOR POWER.16. EXISTING SURGE SUPPRESSION DEVICE FOR ALL COPPER LINES. AT ENTRANCE TO NEW BUILDING, ROUTED THROUGH CONNECTING CORRIDOR LOWER LEVEL. SEPARATE DEVICE FOR EACH LINE.17. EXISTING PROVIDE SEPARATE CONNECTIONS TO SECURITY SYSTEM PANELS LOCATED IN TR-2-3 AND TR-2-4.18. EXISTING SYNCHRONIZATION MODULE(S) AS REQUIRED FOR ALL STROBE CIRCUITS.19. PROVIDE SMOKE DETECTORS AT ALL SMOKE DAMPER PARTITION WALL UNITS AS SHOWN ON MECHANICAL PLAN. PROVIDE CONNECTION AS REQUIRED FOR AUTOMATIC DAMPER CLOSURE AND MANUAL RESET.MRIFSTSTSXSSPVSSCALE:1FIRE ALARM RISER DIAGRAMN.T.S.E5.4BFIRE ALARMGENERAL NOTESAND DIAGRAMD. JAMESC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:42 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\E5-4B - FIRE ALARM GENERAL NOTES AND DIAGRAMS.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 GENERAL NOTES:A.ALL WIRE SIZES INDICATED ARE MINIMUM SIZES. WIRE SIZESHALL BE UPSIZED AS REQUIRED FOR VOLTAGE DROP AND ASNOTED ON DRAWINGS.B.SOME WIRE SIZES MAY BE INDICATED ON THE POWER RISERDIAGRAM.C.DOOR-IN-DOOR CONTINUOUS HINGED FRAME CONSTRUCTIONFOR ALL PANEL BOARDS.D.CIRCUITS INDICATED WITH AN (E) ARE EXISTING, AND SHALLREMAIN UNLESS SPECIFICALLY NOTED OTHERWISE.E.THE "X / Y" DESIGNATION ON VARIOUS LOAD DESCRIPTIONSREFERS TO NEAREST COLUMN LOCATION. WHERE X =HORIZONTAL COLUMN NUMBER AND Y = VERTICAL COLUMNNUMBER.LUMINAIRE SCHEDULETYPEDIMENSIONSMOUNTCONSTRUCTION ANDFINISHDESCRIPTION AND OPTIONSLAMP(S)LUMEN PACKAGEBALLAST(S) / DRIVERSBASIS OF DESIGN ACCEPTABLE MANUFACTURER(S)RL12'X2'RECESSEDSTEEL HOUSING, WHITEFINISH2'X2' LED TROFFER WITH FROSTED ACRYLIC LENS, 4000K LEDSOURCELED (80 CRI)ML- MEDIUM LUMEN(3200-3400 LM)120-277V LED DRIVER, 0-10V DIMIMINGCOLUMBIA LIGHTING LCAT22-40MLG-EDURL22'X4'RECESSEDSTEEL HOUSING, WHITEFINISH2'X4' LED TROFFER WITH FROSTED ACRYLIC LENS, 4000K LEDSOURCELED (80 CRI)VL- VERY HIGH LUMEN(7300 LM)120-277V LED DRIVER, 0-10V DIMIMINGCOLUMBIA LIGHTING LCAT24-40VLG-EDURL36"RECESSEDSTEEL HOUSING, WHITEFINISH6" LED DOWNLIGHT WITH OPEN ALUMINUM REFLECTOR, 4000KLED SOURCE AND (2) 24" BAR HANGERS FOR T-BAR CEILINGSLED (80 CRI)HIGH OUTPUT(1800 LM)277V LED DRIVER, 0-10V DIMMINGPRESCOLITE LC6LED277DM-6LCLED740K8WHWTB24RL94"RECESSEDALUMINUM HOUSING,POWER COATED4" LINEAR RECESSED LED LUMINAIRE WITH STEEL REFLECTOR,FROSTED ACRYLIC LENS AND 4000K LED SOURCE. AVAILABLE IN 4',8' AND 12' LENGTHS AS NEEDED.LED (80 CRI)HO - STANDARDOUTPUT (689 LM/FT)277V LED DRIVER, 0-10V DIMMINGFINELITE HP-4-R-XX-HO-4000K-277V-SC-C1SL15"X48"SUSPENDEDSTEEL HOUSING, WHITEFINISHLED STRIPLIGHT WITH FROSTED ACRYLIC LENS, 4000K LED SOURCELED (80 CRI)ML-MEDIUM LUMEN(5000 LM)120-277V LED DRIVER NON DIMMINGCOLUMBIA LIGHTING LCL4-40ML-EUSL8VARIOUSTRACKALUMINUM HOUSING, BLACKFINISH2-CIRCUIT NORDIC ALUMINUM GLOBAL TRACK, 277V(LENGTH AS INDICATED)N/AN/AN/ALITON / EEMA LIGHTING GROUP - TRACKSL99"X8"HEADALUMINUM HOUSING, BLACKFINISHLARGE LED TRACK HEAD WITH SPECULAR REFLECTOR, 50 DEGFLOOD BEAM, 3500K LED SOURCELED (80 CRI)MEDIUM OUTPUTFLOOD (2176 LM)277V LED DRIVER, 0-10V DIMMINGLITON / EEMA LIGHTING GROUP LTD730W-B45-DLV-T40X412"X8"UNIVERSALDIE-CAST ALUMINUM, BLACKLED EXIT LIGHT WITH BLACK HOUSING, BRUSHED ALUMINUMFACE, GREEN LETTERS/CHEVRONS AND INTEGRATED BATTERYBACKUPLED (80 CRI)N/A120-277V LED DRIVERCOMPASS CEGBLIGHTING CONTROLS SCOPE / SYSTEMS DESCRIPTIONS: DELTA FOURTH FLOORVACANCY CONTROL: VACANCY CONTROL IS MANUAL 'ON' AUTO 'OFF'.OCCUPANCY CONTROL: ALL OFFICES, CONFERENCE ROOMS, MEETING ROOMS, ALLCOMMON AREAS INCLUDING HALLWAYS, CORRIDORS, BATHROOMS, UTILITY AREAS,JANITOR CLOSETS, SHALL OPERATE BASED ON 'OCCUPANCY' CONTROL.OCCUPANCY CONTROL IS AUTO 'ON' AND AUTO 'OFF' BASED ON MOTION ANDOCCUPANCY OF THE AREA. TIMERS SHALL BE SET FOR 10 MINUTES.COMMON AREAS / OPEN OFFICES: THESE AREAS SHALL BE CONTROLLED VIACEILING OC SENSORS FOR LARGE AREAS WITH MULTI-BUTTON SCENE CONTROLSTATIONS PROVIDING DIMMING AND MULTIPLE ZONES OF CONTROL. FOR SMALLEROFFICES WITH SINGLE POINT OF CONTROL AND NO OBSTRUCTIONS, SWITCH UNITSWITH OCCUPANCY SENSORS CAN BE USED. MAKE AND MODEL NUMBERS FORSYSTEM DESIGN BASIS: HBA NX SYSTEMSTORAGE/UTILITY: DIGITAL TIMERS (TD300). MAKE AND MODEL NUMBERS FORSYSTEM DESIGN BASIS: HBA TD300RL1RL2RL3RL9SL1SL8SL9X4TYPEPANEL '4H1' - EXISTING PANEL CONTAINS (11) 3P-20A CIRCUIT BREAKERS.TEXT IN BOLD INDICATES NEW CIRCUITS BEING USED ON THAT BREAKER.TEXT WITH (E) INDICATES EXISTING CIRCUITS ON THAT BREAKER.PANEL '4L4' - EXISTING PANEL CONTAINS THE FOLLOWING CIRCUIT BREAKERS: (3)2P-20A, 2P-35A, (30) 1P-20A, (1) 3P-40, (1) 1P-30A.TEXT IN BOLD INDICATES NEW CIRCUITS BEING USED ON THAT BREAKER.TEXT WITH (E) INDICATES EXISTING CIRCUITS ON THAT BREAKER.SL119"X15"SUSPENDEDCLEAR GLASS, POLISHEDCHROMELED DECORATIVE GLASS PENDANT WITH CRYSTAL GLOBE ANDCHROME FRAME, MEDIUM SIZE WITH 3000K LED SOURCE.PROVIDE 120-277V, 10A ENCLOSED RELAY TO BE WIRED IN LINE.LED (95 CRI)MEDIUM OUTPUT (1895 LM)120V LED DRIVER, 0-10V DIMIMINGSTUDIO ITALIA DESIGN - SKYFALL PENDANT S01-148001H.E. WILLIAMS, FEELUX, WINONAENCLOSED RELAY - FUNCTIONAL DEVICES RIB2421CSL11WATTS3065269W/FT48N/A30220RL2ASAME AS RL2 EXCEPT MEDIUM LOW WATT 1'X4'COLUMBIA LIGHTING LCAT14-40MWG-EDU1'X4'RL2AMW-MEDIUM LOW WATT(4000 LM)33E6.4AELECTRICALSCHEDULESD. JAMESC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out10/6/2016 9:01 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\E6-4A - ELECTRICAL SCHEDULES.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 ONOFFLVHVGSVC PWRSVC PIN Building Automation HUBBELLR Building Automation HUBBELLR VioletN Dimming Ballast#1Black (120-277 VAC) White (Neutral)Grey RedWhite NX-1RD Room ControllerWhite BlackRed+OCCPC-Red 24VDCBlueBlack18AWG standard low voltage wireCAT5 Cable+OCCPC-Red 24VDCBlueBlack18AWG standard low voltage wire(As required per Room - See drawings for Occupancy sensorrequiresments in each room or area)(As required per Room - See drawings for Photo Sensor requiresments in eachroom or area)NXDSNXOS-OMDT2NXOS-OMDT2SNXRC - 2 RD(TYPICAL-MIN)SCALE:2ROOM WITH 1 DIMMING LOAD (KITCHENETTE)N.T.S.LVGGHHVVSVC PWRSVC PIN Building Automation HUBBELLR VioletN Dimming Driver #1NDimming Driver #2Black (120-277 VAC) White (Neutral)Grey Red Blue Violet Grey WhiteNX-2RD Room ControllerWhite2-Relay VersionBlackRedBlue+OCCPC-Red 24VDCBlueBlack18AWG standard low voltage wire(As required per Room - See drawings for Occupancy sensor requiresments in eachroom or area)orCAT5 CableNXOS-OMDT2NXRC - 2 RDROOMS(Wall mount - only where ceiling mount will not work)NXOS-LODTSCALE:4ROOM WITH 2 DIMMING LOAD (RESTROOMS)N.T.S.TMGB PANEL BOARDMETAL BUILDING FRAMEROOM 013 - (IDF-B-2) EXISTINGELECTRICAL ROOM 030ROOM 109 - (IDF-1-4) EXISTINGROOM 222- (IDF-2-4) EXISTINGROOM 212 - (TR-2-3) EXISTINGROOM 333 - (IDF-3-1) EXISTINGROOM 311 - (IDF-3-2) EXISTINGROOM 115- (IDF-1-3) EXISTINGROOM 217 - (IDF-2-1) EXISTING(EXISTING TGB)#6 AWG (TEBC) TELECOMMUNICATIONS EQUIPMENT BONDINGCONDUCTOR CONNECTING EQUIPMENT TO GROUNDINGBUSBAR (TYPICAL). PROVIDED BY ELECTRICAL CONTRACTOR.SIZE TO PROVIDE 20% SPARECAPACITY/SURFACE.BACKBOARD EQUIPMENTPROVIDE #6 AWGGROUND CONDUCTOR#1/0 AWG(TYPICAL)#1/0 AWG GROUND & BOND TOMAIN ELECTRICALGROUNDING ELECTRODESYSTEM PROVIDED BYELECTRICAL CONTRACTOR.NOTE: USE TWO HOLE LONG BARRELIRREVERSIBLE CRIMP LUG FOR ALLCONNECTIONS TO GROUND BUSBAREXISTING #1/0 AWG COILEDAT 3RD FLOOR CEILINGBRAZED ENDTGB EQUIPMENT RACKS/TRAYWALLBOARDLOCAL POWER PANELMETAL BUILDING FRAME(TGB)4TH FLOOR - (IDF-4-2)TGB EQUIPMENT RACKS/TRAYWALLBOARDLOCAL POWER PANELMETAL BUILDING FRAME(TGB)4TH FLOOR - (IDF-4-1)EXISTINGEXISTINGSCALE:6DETAIL - TELECOM GROUNDINGN.T.S.NOTES:1. ALL CONDUITS AND SLEEVES NOT TERMINATING IN A JUNCTION BOX SHALL BE TERMINATEDWITH A PLASTIC CONDUIT BUSHING BY CONTRACTOR PRIOR TO PULLING CABLE.2. IF "J-HOOKS" ARE SUBSTITUTED FOR CONDUIT, THE FOLLOWING CONDUITS MAY NOT BEELIMINATED.A. THE CONDUIT UP AND TURNED OUT TO ABOVE CEILING LINE FROM BACK BOXB. A CONDUIT STUB FROM ABOVE CEILING LINE IN SAME AREA, THROUGH WALL ANDSECURED TO CABLE TRAY WHERE CEILING IS NOT ACCESSIBLE.C. ALL CONDUIT ENDS SHALL HAVE BUSHINGS AND BE LABELED.WHERE BOX IS SURFACED MOUNTED.3. WHERE DEVICES ARE INSTALLED IN FINISHED AREAS WITH PLASTER WALLS AND ACCESSIBLECEILINGS, THE ROUGH-IN MAY BE A "RING AND STRING" TYPE OF ROUGH-IN, UNLESS THEROUGH-IN IS NOTED AS SPARE OR FUTURE IN NATURE. WHERE DEVICES ARE INSTALLED, NO RACEWAYNEEDS TO BE INSTALLED UNLESS THE EXCEPTIONS ARE MET. IE: SURFACED MOUNTED, ETC.4. ALL DATA/TELECOM BOXES SHALL BE MIN. 4" SQUARE BOX WITH SINGLE GANG OPENING.PROVIDE MUD RING WHERE APPLICABLE.BACKBOXWALLCABLE TRAYCONDUIT TO BE SECURED TO THESIDE OF THE CABLE TRAY.HORIZONTAL CABLINGFINISHED CEILINGNON-ACCESSIBLEMINIMUM 1" CONDUITWITH PULL STRINGTELECOMMUNICATIONSOUTLETSCALE:7DETAIL - CABLE PATHWAYN.T.S.GENERAL NOTE:A. MAINTAIN CLEAR SPACE AROUNDRACKS AS LISTED:3 FT MIN IN FRONT/BACK2 FT MIN. ON SIDESCODED NOTES:1. INSTALL 24" W x 78" H x 16" DFLOOR MOUNTED RELAY STYLEOPEN RACK. COORDINATEWITH POWER PLANS. PROVIDEINSTALLATION TO MEET ALLNEC REQUIREMENTS. REFER TOSPECIFICATIONS FOR ADDITIONAL2. NOT USED.3. PROVIDE ALL PATCH CABLES.4. NOT USED.5. REFER TO RACK AND PATCHPANEL SCHEDULE FOR EACHIDF AND AV CLOSET.8" BETWEEN RACKSSCOPE.6. 1U SPACE BETWEEN SETS.7. SURFACE MOUNTED DOUBLEDUPLEX RECEPTACLES ADJACENTTO ALL RACKS WITH DEDICATED120V/20A CIRCUITS.(2) FIBER PAIRS PERCPP TO MDF. (DOESNOT INCLUDE ANYSPARES SCHEDULED)8. NOT USED.SPACE9. AV CONTRACTOR SHALL PROVIDEINDIVIDUAL UPS UNITS, RACK MOUNTEDAS REQUIRED TO PROVIDE ORDERLYSHUT DOWN OF ALL EQUIPMENT RACKMOUNTED.10.PROVIDE INDIVIDUAL UPS UNITS, RACKMOUNTED, AS REQUIRED TO PROVIDEORDERLY SHUT DOWN OF ALL EQUIPMENT.11. PROVIDE MINIMUM OF ONE SURGEPROTECTION DEVICE AT EACH IT RACK.ALL CAMERAS SHALL BE ROUTED VIAA SURGE PROTECTION UNIT.12. PROVIDE A SURGE PROTECTION ANDACTIVE FILTERING UNIT FOR EACHCIRCUIT OR EACH UPS SERVING EVERYRACK.21RESERVED TOREMAIN EMPTY5DATA RACK18"18"7772" AFF72" AFF366610UPS 5 KW9GENERAL NOTES:A. FPP (FIBER PATCH PANEL) - COMMSCOPE # RFE-SLC-IS-EMT-BK/IU-PNL(1U) #760147439 (OFCI)B. CPP (COPPER PATCH PANEL) - COMMSCOPE # UNP-U-610-1U-24 (1U) #760180042 (OFCI)C. F/C (FIBER/COPPER SWITCH) - CISCO # SW-C3850-12X48U-E (1U) (OFOI)D. SC (STACKING CABLES) - CISCO # CAB-SPNR-150CM (OFOI)E. UM (UPLINK MODULES) - CISCO # C3850-NM-4-10G (OFOI)F. RACKS - RELAY TYPE (2) POSTS - TRIPP LITE 45U 2-POST OPEN FRAME #SR2POST (OFCI)G. 6P - 6" CAT 6 PATCH CABLESH. AF - ARMORED FIBER HOME RUN PAIRS - MULTI-MODE PLENUM RATED;24 COUNT COMMSCOPE # 760134981 - PO24 - 0Z - SK - FSUBK.I. DPM (DUPLEX LC READY PATCH MODULES) -J. TV - PROVIDE COMMSCOPE # UMP-U-10G-2U-24(2U) FOR CCTV SYSTEM. REFER TO IP CAMERA SCHEDULE.NOTES:1. PROVIDE ALL CONNECTIVITY FROM STATION JACKS TO IDF VIA MIN.CAT 6 NETWORK CABLES/FIBER.2. A 24 PORT CPP, INDICATED HERE, ON THE THIRD FLOOR AS PART OF PREVIOUSPROJECT, SHALL BE RELOCATED TO 4TH FLOOR TO SERVE 4TH FLOOR BY THISCONTRACTOR.3. SECURE RACKS TO FLOOR AND TO WALL AT TOP OF UNIT. USEINSULATED ANCHORS, DO NOT CREATE DIRTY LOOP.DATA RACKS SCHEDULEROOMRACKSFPPCPPF/CSCUM6PAF (PAIRS)AF (SPARES)DPMTVNOTE114 X 4836121506218-112 X 24, 3 X 4836121756-18-6IDF-4-1IDF-4-2K. REFER TO T501 FOR IDF/ROOM NUMBER COORDINATION. (ALL IDF LABELS ARE LISTED ALONGSIDE THE FLOOR PLAN ROOM NAMES ON THE ROUTING DIAGRAM.)4.ALL FIBER ENDS SHALL BE ALL CABLES AND FIBER SHALL BE TERMINATED ANDTESTED UNLESS NOTED OTHERWISE.5.OFCI (OWNER FURNISHED CONTRACTOR INSTALLED)OFOI (OWNER FURNISHED OWNER INSTALLED)6.ALL CCTV / SECURITY CAMERAS ON THE FOURTH FLOOR AND ROOF ARESERVED OUT OF THE THIRD FLOOR AND SHALL BE MAINTAINED.7.THIS CONTRACTOR SHALL EXTEND FIBER INSTALLED IN PREVIOUS PROJECTTHAT IS COILED UP DIRECTLY BELOW THE FLOOR NEAR EACH RACK LOCATION.ALL FIBERS SHALL BE TERMINATED AND TESTED. ALL REPORTS SHALL BEREVIEWED AND SIGNED OFF BY THE OWNER AS SOON AS COMPLETED.8.ITEMS IN TABLE #1 BELOW ARE OFCI ITEMS.6TABLE #2SCALE:1DETAIL - RACK ELEVATIONSN.T.S.NOTES:1. PROVIDE FIRE CAULKING AT RATED WALLS TOMAINTAIN RATING.2. PROVIDE FIRE RATED FILLER IN CONDUITSPENETRATING RATED WALLS.3. FILL CONDUIT IN NON-FIRE RATED WALLSPENETRATIONS WITH FIBERGLASS INSULATION.4. REFER TO FLOOR PLANS FOR QUANTITIES OFSLEEVES REQUIRED. IF NO QUANTITY IS INDICATED,PROVIDE THREE SLEEVES.RIGID GALVANIZEDSTEEL CONDUITSLEEVECONDUIT SIZE AND QUANTITYSHALL MATCH THE CABLETRAY CAPACITY AT A MINIMUM.BUNDLE OFTELECOMMUNICATIONSCABLEBOND EVERY SECTION AT MIN.OR MORE PER MANUFACTURER'SSUGGESTION (TYP)CABLE TRAYHANGERHANGERDEDICATEDGROUND WIRECAULKSCALE:3DETAIL - CABLE TRAY PENETRATIONN.T.S.SCALE:5MULTI-DIMMER OCCUPANCY SENSOR WIRING DIAGRAM(OPEN OFFICE AREAS)N.T.S.E7.4AELECTRICALDIAGRAMSD. JAMESC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:42 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\E7-4A - ELECTRICAL DIAGRAMS.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 DDDDDDDDD225ADL4L14H24L2225ADL225ADL400A225A200A100A225A225A400A225A225AFTL225AFTL225AFTL225AFTL225ABUS225AFTL225AFTL225AFTL225AFTL225A225AFTL225AELECTRICAL - ROOM 030MECH ROOM 012MODEL SHOP225AKITCHEN DISPLAY AREA PULL SECTION480/277V, 3 PHASE2000A(8) 4" CONDUTSELEVATOR #1 & #2LOWERLEVELFIRSTFLOORSECONDFLOORTHIRDFLOORROOFLEVELFOURTHFLOOR2000 AMPS480/277 VOLT225A225A60A60A400A400AMECHANICAL & SUPPLY 022FTL208/120 VOLT800AMPS208/120 VOLT600AMPS100A3D PRINTING100AAVLOAD100AEM100AATS-1CNTRL TO GEN SETENL 225A100AMCB014MLO225AFTL225AMLO35k AICFTLFTLFTLFTLFTLMLOMLOMLO3.54.52.51.56.55.536.312.315.313.316.314.311.39.310.38.37.3151716182219913111412107568421242517.318.32021233.35.34.32.31.39.97.914.911.920.918.925.919.320.321.322.323.324.325.31212161221121212121616.316413161612.38.312.3161212121218.31219168.31116.3169.39.39.312121261212121212661213.3441263.33.382512INTERIOREXTERIORUTILITYXFMRPRIMARY BYLOCAL UTILITYCOMPANY300KVAXFMRTBACONTACTORC-1EPO-BL5KEY RESET225KVAXFMRTBB150KVAXFMRTBC75KVAXFMRTBD150KVAXFMRTBETO SHUNT TRIPCIRCUIT BREAKER75KVAXFMRTBF(UT-1)2-1/2"C3P/150 AMP21012121114141515511115131310PANEL LEGEND:EXAMPLE:3H1First Panel in the SeriesH = 277/480 Volt, L = 120/208 Volt3 = Third Floor39966DP = Distribution PanelX = Generator PowerXU = UPS Power8811. BUS DUCT: MOUNTED OVER EQUIPMENT IN WET LABS AND LIFE CYCLE TESTING. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION.12. BUS PLUGS WITH RECEPTACLES: QUANTITY AND TYPES AS NOTED ON PLANS.13. EPO (KEY RESET) SHALL SHUNT TRIP THE CIRCUIT BREAKER THAT FEEDS THIS UNIT. BREAKER TO BE MANUAL RESET.14. ELECTRICAL CONTRACTOR SHALL CONNECT FEEDER TO DISCONNECT PROVIDED BY ELEVATOR MANUFACTURER. EXTEND FEEDER TO SHUNT TRIPCIRCUIT BREAKER IN HMDP. PROVIDE REQUIRED RELAY(S) AND WIRING FORELEVATOR SHUT DOWN TO SHUNT TRIP BREAKER.15. PROVIDE CONNECTION TO EQUIPMENT16. EXTEND (1) 2-1/2" CONDUIT INTO FLOOR ABOVE AND CAP 6" ABOVE FINISHED FLOOR FOR FUTURE.17. PROVIDE 400 AMP, 208/120 VOLT NEMA 1 FUSED DISCONNECT SWITCH WITH 225 AMP FUSES.18. PROVIDE 400 AMP, 208/120 VOLT NEMA 1 FUSED DISCONNECT SWITCH WITH 400 AMP FUSES.ELECTRICAL NOTES:1. GROUNDING ELECTRODE SYSTEM PER 250 OF THE CURRENT NEC.2. FEEDER FOR UPS PANEL: EXISTING UPS DISTRIBUTION AT NORTH END OF EXISTING BUILDING. UTILIZE EXISTING SPARE 200A BUCKET. PROVIDE FUSES.3. FEEDER FROM EXISTING GENERATOR: EXISTING GENERATOR PANEL LOCATEDIN EXISTING BUILDING. EXTEND FEEDER FOR STORM WATER PUMPS AND SEWAGE EJECTOR PUMPS. SEE SHEET E126 FOR ROUTING..4. FUSES PER EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. PROVIDE WITH AUXILIARY CONTACTS AND (2) #14 TO CONTROLLER FOR MAINTENANCESHUT DOWN.5. CONCRETE CAP WITH RED DYE MARKING.6. SEE ALTERNATE DESCRIPTION ON THIS SHEET FOR WORK ASSOCIATED WITHTHIS EQUIPMENT.7.PROVIDE 400 AMP, 480/277 VOLT NEMA 1 FUSED DISCONNECT SWITCH WITH 400AMP FUSES.8. PROVIDE WIREWAY UNDER PANELS SIZED FOR TWO (2) PANELS.9. SHUNT TRIP CIRCUIT BREAKER FOR FEEDER CIRCUIT.10.ALL EQUIPMENT IN THE MODEL SHOP LAB SHALL BE CIRCUITED FROM THISPANEL. PANEL SHALL HAVE THE CAPABILITIES TO BE LOCKED OUT VIA 'EPO' SWITCH WITH KEY RESET. UPON KEYED RESET THE CONTRACTOR SHALL AUTOMATICALLY PULL BACK TO CLOSED POSITION.8441515151577GENERAL ELECTRICAL NOTES:A. ALUMINUM FEEDERS: FEEDERS OVER 100A (OCP) MAY BE ALUMINUM.B. SERIES RATED FAULT CURRENT BREAKERS ARE NOT ALLOWED.C. NO LOAD CENTERS ALLOWEDD. ALL PANELS TO BE FULL FRONT HINGED DOOR-IN-DOOR.181777.6666661H11L1BL12H12L13H13L14H1BH11H21L2BL62H22L23H23L2BH3BL5BXUL1BXUL21KL11L4BL32L33L3HMDP2XUL12XUL2BH4BL8BD-1TO 'HMDP'TO 'HMDP'EPO-BD-1EPO-BD-2BLDP1BLDP2RTU-1RTU-2RTU-3RTU-44L4MUA2L4BXH1BD-2BL71O, 3W (100% NEUTRAL BAR)40A THRU 50A 3-#8, 1-#10G., 3/4"C.60A 3-#6, 1-#8G., 3/4"C.5A THRU 20A 3-#12, 1-#12G., 3/4"C.25A THRU 35A 3-#10, 1-#10G., 3/4"C.90A THRU 100A 3-#3, 1-#8G., 1 1/4"C.70A THRU 80A 3-#4, 1-#8G., 1"C.3O, 4W, WYE (100% NEUTRAL BAR)CONDUIT / WIRE SCHEDULE40A THRU 50A 4-#8, 1-#10G., 3/4"C.90A THRU 100A 3-#3, 1-#8G., 1 1/4"C.350A 2 SETS OF 3-#2/0, 1-#3G., 1 1/2"C.125A 3-#1, 1-#6G., 1 1/4"C.400A 3-#500, 1-#3G., 3"C.150A 3-#1/0, 1-#6G., 1 1/4"C.300A 3-#350, 1-#4G., 2 1/2"C.250A 3-#250, 1-#4G., 2"C.225A 3-#4/0, 1-#4G., 2"C.200A 3-#3/0, 1-#6G., 2"C.175A 3-#2/0, 1-#6G., 1 1/2"C.110A 3-#2, 1-#6G., 1 1/4"C.450A 2 SETS OF 4-#4/0, 1-#2G., 2 1/2"C.800A 2 SETS OF 4-#600, 1-#1/0G., 3 1/2"C600A 2 SETS OF 4-#350, 1-#1G., 3"C500A 2 SETS OF 4-#250 , 1-#2G., 2 1/2"C.400A 4-#500, 1-#3G., 3 1/2"C.90A THRU 100A 4-#3, 1-#8G., 1 1/4"C.350A 2 SETS OF 4-#2/0, 1-#3G., 2"C.3O, 3W, DELTA (NO NEUTRAL BAR)110A 4-#2, 1-#6G., 1 1/4"C.125A 4-#1, 1-#6 G., 1 1/4"C.150A 4-#1/0, 1-#6G., 1 1/2"C.250A 4-#250, 1-#4G., 2 1/2"C.225A 4-#4/0, 1-#4G., 2 1/2"C.175A 4-#2/0, 1-#6G., 1 1/2"C.200A 4-#3/0, 1-#6G., 2"C.300A 4-#350, 1-#4G., 3"C.60A 4-#6, 1-#8G., 1"C.70A THRU 80A 4-#4, 1-#8G., 1"C.5A THRU 20A 4-#12, 1-#12G., 3/4"C.25A THRU 35A 4-#10, 1-#10G., 3/4"C.1000A 3 SETS OF 4-#400, 1-#3/0G., 4"C1600A 4 SETS OF 4-#600, 1-#250G., 4"C2000A 5 SETS OF 4-#600, 1-#250G., 4"CNOTES:1.IF NO SIZE IS SHOWN FOR A CONDUCTOR OR CONDUIT, THE SIZE IS TO BE CHOSEN BASED ON THE LIST BELOW.2.NOT ALL SIZES SHOWN ARE USED.3.CONDUIT SIZE SHOWN IS MINIMUM SIZE AND BASED ON THHN, THWN, OR XHHW INSULATION. INCREASE AS NECESSARY FOROTHER TYPES.4.AMPERAGE SHOWN IS THE NOMINAL RATING FOR THE CONDUCTORS INDICATED. CONDUCTORS WITH A HIGHER CURRENTRATING MAY BE SHOWN ON THE DOCUMENTS TO ACCOUNT FOR VOLTAGE DROP, OR FUTURE EXPANSION OF A SERVICE ORFEEDER.5.SIZING BASED ON 90° CONDUCTOR & 75° TERMINATION. PER NEC 110.14, IF TERMINATION RATING LESS THAT 75°,CONDUCTOR MUST BE DE-RATED ACCORDINGLY AND CONDUIT SIZING ADJUSTED.500A 2 SETS OF 3-#250, 1-#2G., 2"C.800A 2 SETS OF 3-#600, 1-#1/0G., 3"C.1200A 3 SETS OF 4-#600, 1-#3/0G., 4"C700A 2 SETS OF 4-#500, 1-#1/0G., 3 1/2"C40A THRU 50A 3-#8, 1-#10G., 3/4"C.60A 3-#6, 1-#8G., 3/4"C.70A THRU 80A 3-#4, 1-#8G., 1"C.5A THRU 20A 3-#12, 1-#12G., 3/4"C.25A THRU 35A 3-#10, 1-#10G., 3/4"C.1#6G.1W (PANEL GROUND)1#8G.1#2G.1#4G.1#2/0G.1#1/0G.1#3/0G.450A 2 SETS OF 3-#4/0, 1-#2G., 2"C.600A 2 SETS OF 3-#350, 1-#1G., 2 1/2"C700A 2 SETS OF 3-#500, 1-#1/0G., 3"C1000A 3 SETS OF 3-#400, 1-#3/0G., 3"C1200A 3 SETS OF 3-#600, 1-#3/0G., 3"C1600A 4 SETS OF 3-#600, 1-#250G., 3 1/2"C2000A 5 SETS OF 3-#600, 1-#250G., 3 1/2"C(51-C)413(EAST)(WEST)CONNECT TO FTLIN EXISTING PANELNEW CORENEW FEEDERNEW 480V PANELNEW 120/208VPANELEXISTING PANELEXISTING PANELTO REMAINCONNECT TO EXISTINGSPARE 225A-3PNEW 120/208VPANELNEW CORENEW CORENEW CORENEW COREE7.4BPOWER RISERDIAGRAMD. JAMESC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:42 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\E7-4B - POWER RISER DIAGRAM.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724SCALE:1POWER RISER DIAGRAMN.T.S. AAHWCWHWRSANVSTGSSAMPGPDHDGPHGPMHPHGTHZGALLONS PER DAYHHEADGALLONS PER HOURGALLONS PER MINUTEHEIGHTHORSEPOWERHERTZVOLTVENT THRU ROOFVACUUM (MED GAS)WATERVACUUM BREAKERVWVTRVBWMVFIN FL EL°FEXPEXHFDEXISTGAFOVFOSFORFOFGALFTEXISTINGEXPANSIONDEGREES FAHRENHEITEXHAUSTFFLOOR DRAINGAUGEFUEL OIL TANK VENTFUEL OIL SUPPLYFUEL OIL RETURNFUEL OIL FILLFINISHED FLOOR ELEVATIONGGALLONSFOOT OR FEETDNDIADIDWDWGEQUIPELDEPTDCU FTCONTCU INDIAMETERDOWNDEIONIZED WATERDISTILLED WATERDRAWINGEQUIPMENTELEVATIONEDEPARTMENTDCONTINUATIONCUBIC FEETCUBIC INCHDRAINSTANDARDSPECIFICATIONSTRAINERSHEETSOFT POTABLE WATERTEMPERATURETOP ELEVATIONTEMPERED WATER SUPPLYTHERMOSTATIC MIXING VALVETYPICALUNLESS NOTED OTHERWISESTDSTRSPECSHTSWTEMPTTWSTMVTETYPUVUNOPRESSURE REDUCING VALVEPSI GAUGEPOUNDS PER SQUARE INCHPARTS PER MILLIONPRESSUREPUMPED DISCHARGEREVERSE OSMOSIS WATERRECIRCULATING PUMPREVOLUTIONS PER MINUTEREDUCED PRESSURE BACKFLOW PREVENTERSECONDPRESSPSIGPRVPSIPPMPDRORRCPRPMRPBPSSECABBREVIATIONSCFHAWAVAVGAUTOBFVBOPBLDGACFMCAPCUBIC FEET PER HOURACID WASTEACID VENTCBAVERAGEAUTOMATICBUTTERFLY VALVEBUILDINGBOTTOM OF PIPECOMPRESSED AIR (SHOP AIR)CUBIC FEET PER MINUTECAPACITYAPPROXAEMAABVAFFAMPANESTHESIA EVACUATIONCOMPRESSED AIR (MEDICAL GAS)AABOVEABOVE FINISHED FLOORAPPROXIMATEAMPERENUMBERNOT TO SCALENON-POTABLE WATEROWNER FURNISHED, CONTRACTOR INSTALLEDOUTSIDE STEM & YOKE VALVEOXYGENNITROGENLIQUID OXYGENNOT IN CONTRACTNORMALLY OPENMAXIMUMNOT APPLICABLEMINIMUMNORMALLY CLOSEDNO.NTSNPWOOS&YOOFCINLOXNMNICNOMAXN/AMINNCINCHESINVERT ELEVATIONINDIRECT WASTEPOUNDSKILOWATTLENGTHLINEAR FEETIINIWINV ELLKKWLBLGLFN2ONITROUS OXIDEFODFUEL OIL DISCHARGEFOGFUEL OIL GAUGE LINEFOOFUEL OIL OVER FLOW LINEARARGONHEHELIUMHHYDROGENLNLIQUID NITROGENARCHITECTBFBELOW FLOORCONNCONNECTION OR CONNECTHVACHEATING, VENTILATING AND AIR CONDITIONINGMECHMECHANICALMFGMANUFACTURERPLBGPLUMBINGRDROOF DRAINSRDSECONDARY ROOF DRAINPSFUEL POLISH SUPPLYSTSTLSTAINLESS STEELTOPTOP OF PIPEARCHGENERAL NOTESCOCOPRFUEL POLISH RETURNPX.XAPX.X1WASH FOUNTAINWFURINALURWATER CLOSETWCSINKSSHOWERSHMOP SINKMSEWCELECTRIC WATER COOLEREEMERGENCY FIXTURELAVATORYLBTBATHTUBCSCLINIC SINKSYMBOLS LISTPIPINGDOMESTIC HOT WATERDOMESTIC COLD WATERDOMESTIC HOT WATER RETURNSANITARYVENTSTORMNATURAL GASPIPING (FITTINGS, VALVES, AND MISCELLANEOUS)DROPRISETEECAPFLOW ARROWPUMPBUTTERFLY VALVEBALL VALVECHECK VALVEBALANCE VALVESTRAINERUNIONTEMPERATURE & PRESSURE RELIEF VALVETHERMOMETERMETERPIPE SLEEVEPRESSURE REDUCING VALVEPRESSURE/TEMPERATURE TEST PLUGGATE VALVE OR GENERAL SERVICE VALVEGLOBE VALVEPLUG VALVESOLENOID VALVEGAS PRESSURE REGULATOROUTSIDE STEM & YOKE VALVEREDUCED PRESSURE BACKFLOW PREVENTERWATER HAMMER ARRESTORPRESSURE GAUGE WITH STOPCOCKAQUASTATWALL HYDRANT OR HOSE BIBBCLEANOUTCLEANOUT AT FLOOR OR AT GRADESECONDARY STORMFLOOR OR AREA DRAINROOF DRAINNOTATIONSDOMESTIC WATER RISERSANITARY STACK1. COORDINATE EXACT REQUIREMENTS AND LOCATION OF WORK WITH THE WORK OFOTHER TRADES PRIOR TO FABRICATION. PROVIDE ADDITIONAL OFF-SETS ANDSECTIONS OF PIPING AS MAY BE REQUIRED TO MEET THE APPLICABLE JOBCONDITION REQUIREMENTS. VERIFY EXISTING JOB-SITE ELEVATIONS, DIMENSIONS,AND CONDITIONS, PRIOR TO FABRICATION OR INSTALLATION OF THE WORK.COORDINATE EXACT ROUTING OF PIPING WITH OTHER TRADES SO THAT NOCONFLICTS OCCUR WITH DUCTWORK, PIPING, LIGHTS, STRUCTURE, ETC.2. ALL SEALS, BEARINGS, PACKINGS, AND ACCESSORIES FOR ALL EQUIPMENT AND/ORPIPING SPECIALTIES SHALL BE SUITABLE FOR THE CONTINUOUS OPERATIONALTEMPERATURES, PRESSURES AND CHARACTERISTICS, OF THE SYSTEMS THEY SERVE.3. VISIT THE SITE OF THE WORK AND DETERMINE AN EXACT KNOWLEDGE OFCONDITIONS AFFECTING THE EXECUTION OF WORK. AFTER VISITING THE SITE,REQUEST SUCH FURTHER INFORMATION AND/OR CLARIFICATIONS AS NECESSARY TOFULLY UNDERSTAND THE WORK REQUIRED AND TO PROPERLY ESTIMATE COSTS. THERENDERING OF A PROPOSAL OR BID TO PERFORM THE WORK SHALL REPRESENTTHAT THE SITE HAS BEEN VISITED AND ALL CONDITIONS AFFECTING PERFORMANCEOF THE CONTRACT HAVE BEEN NOTED.4. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT AND COMPLETELY PACKEDWITH FIRE STOP MATERIAL BY TRADE CONTRACTORS.5. PROVIDE NEW DOMESTIC WATER, SANITARY WASTE, STORM DRAINAGE, NATURALGAS, VENT AND PROCESS WATER SYSTEMS FOR THIS BUILDING. PROVIDE ALLNECESSARY COMPONENTS FOR FULLY OPERATIONAL SYSTEM. INSTALL SYSTEMS INACCORDANCE WITH STATE REQUIREMENTS AND LOCAL AUTHORITY HAVINGJURISDICTION.6. COORDINATE THE LOCATION OF ALL UTILITY CONNECTION POINTS, FLOOR DRAINSAND HUB DRAINS FOR EQUIPMENT WITH OTHER TRADES.7. THE CONTRACTOR IS TO VERIFY THE EXACT SERVICE OF ANY EXISTING PIPING ORDUCTWORK PRIOR TO INSTALLING ANY NEW CONNECTIONS. ANY DISCREPANCIESBETWEEN THE CONSTRUCTION DOCUMENTS OR THE DESIGN INTENT AND ACTUALCONDITIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ENGINEERIMMEDIATELY, PRIOR TO INSTALLING SAID CONNECTION.COMPRESSED AIRS8. NEW PLUMBING VENTS SHALL CONNECT TO THE EXISTING VENT SYSTEM AT THE VENT STUBS PROVIDED. NO NEW VENT-THRU-ROOF SHALL BE INSTALLED.P0.4PLUMBINGGENERALINFORMATIONSHEETD. TOWNSENDD. TOWNSENDDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:43 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\P0-4 - PLUMBING GENERAL INFORMATION SHEET.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 REF.REF.UPUPUPUPAABBCCDDEEFFGGHHIIJJ1122334455667788X3X44.3A.4A.4H.8SCALE:1THIRD FLOOR PLUMBING DEMOLITION PLAN1/8"=1'-0"4'8'16'0N111223331112344445GENERAL NOTES:A.EXISTING WORK SHOWN IS BASED ON RECORDDRAWINGS AND FIELD SURVEYS. CONTRACTOR IS TOFIELD VERIFY ACTUAL LOCATIONS OF EXISTING WORKPRIOR TO BID.B.SANITARY PIPING SHALL BE INSTALLED SLOPED AT AMINIMUM OF 1/8" PER FOOT.CODED NOTES:1.REMOVE EXISTING SANITARY STUB CAP ANDPREPARE PIPING FOR NEW CONNECTION.2.EXISTING DOMESTIC HOT, COLD AND HOT WATERRETURN RISERS.3.EXISTING VENT RISER.4.EXISTING SANITARY RISER.5.EXISTING COLD WATER RISER.PD1.3THIRD FLOORPLUMBINGDEMOLITIONPLAND. TOWNSENDC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:43 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\PD1-3 - THIRD FLOOR PLUMBING DEMO PLAN.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.comArea of WorkKey Plan100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 SCALE:4'8'16'0N4"C.O.C.O.ST 4"C.O.C.O.ST4"ST6" ST4"C.O.C.O.C.O.STST 4"6"8"C.O.4"6"6"4"4"ST STST ST4"1FOURTH FLOOR PLUMBING DEMOLITION PLAN1/8"=1'-0"VVVV VVVVVA ABBCCDDEEFFGGHHIIJJ11223344556677884.3A.4A.4H.8112133114444455555567777555777764442113ElevatorELEV 2ElevatorELEV 1StairSTR 1StairSTR 2GENERAL NOTES:A.EXISTING WORK SHOWN IS BASED ON RECORDDRAWINGS AND FIELD SURVEYS. CONTRACTOR IS TOFIELD VERIFY ACTUAL LOCATIONS OF EXISTING WORKPRIOR TO BID.B.SANITARY PIPING SHALL BE INSTALLED SLOPED AT AMINIMUM OF 1/8" PER FOOT.C.INSULATE NEW AND EXISTING PVC PIPING WITH 25/50PLENUM WRAP FOR PIPING IN RETURN AIR PLENUM.CODED NOTES:1.REMOVE EXISTING VENT STUB CAP AND PREPAREPIPING FOR NEW CONNECTION.2.REMOVE EXISTING SANITARY STUB CAP AND PREPAREPIPING FOR NEW CONNECTION.3.REMOVE EXISTING DOMESTIC HOT AND COLD WATERCAPS AND PREPARE PIPING FOR NEW CONNECTIONS.4.EXISTING VENT PIPING TO REMAIN.5.EXISTING STORM PIPING TO REMAIN.6.EXISTING VENT THRU ROOF TO REMAIN.7.EXISTING STORM PIPING UP TO ROOF DRAIN TOREMAIN.PD1.4FOURTH FLOORPLUMBINGDEMOLITIONPLAND. TOWNSENDC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:42 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\PD1-4 - FOURTH FLOOR PLUMBING DEMO PLAN.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.comArea of WorkKey Plan100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 SCALE:1THIRD FLOOR PLUMBING PLAN1/8"=1'-0"4'8'16'0N1P4.4 2P4.4 REF.REF.UPUPUPUPAABBCCDDEEFFGGHHIIJJ1122334455667788X3X44.3A.4A.4H.8GENERAL NOTES:A.EXISTING WORK SHOWN IS BASED ON RECORDDRAWINGS AND FIELD SURVEYS. CONTRACTOR IS TOFIELD VERIFY ACTUAL LOCATIONS OF EXISTING WORKPRIOR TO BID.B.SANITARY PIPING SHALL BE INSTALLED SLOPED AT AMINIMUM OF 1/8" PER FOOT.P1.3THIRD FLOORPLUMBING PLAND. TOWNSENDC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:43 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\P1-3 - THIRD FLOOR PLUMBING PLAN.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.comArea of WorkKey Plan100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 UPAABBCCDDEEFFGGHHIIJJ1122334455667788X3X44.3A.4A.4H.8UPSCALE:1FOUTH FLOOR PLUMBING PLAN1/8"=1'-0"4'8'16'0N4"C.O.C.O.ST 4"C.O.C.O.ST4"ST6" ST4"C.O.C.O.C.O.STST 4"6"8"C.O.4"6"6"4"4"ST STST ST4"ElevatorELEV 2ElevatorELEV 1StairSTR 1StairSTR 23P4.4 4P4.4 1332333332ElevatorELEV 2ElevatorELEV 1StairSTR 1StairSTR 2Office434Office433Office432Elevator Lobby401Work Area/Storage423Office430R.R.415R.R.416IT/Elec413Storage414Office412Office411Office410Vault418Office406Office405Office419Office420Office404Office403Office421Office409Office408Office407W.R.R.426M.R.R.427Jan.425Office424IDF428Meeting431Internal Controls435Restroom Corridor429CustomerSolutions422Kitchenette417Accounting/Financial402GENERAL NOTES:A.EXISTING WORK SHOWN IS BASED ON RECORDDRAWINGS AND FIELD SURVEYS. CONTRACTOR IS TOFIELD VERIFY ACTUAL LOCATIONS OF EXISTING WORKPRIOR TO BID.B.SANITARY PIPING SHALL BE INSTALLED SLOPED AT AMINIMUM OF 1/8" PER FOOT.CODED NOTES:1.EXISTING VENT THRU ROOF.2.EXISTING STORM RISER.3.EXISTING STORM UP TO EXISTING ROOF DRAIN.P1.4FOURTH FLOORPLUMBING PLAND. JAMESC. MURRAYDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:43 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\P1-4 - FOURTH FLOOR PLUMBING PLAN.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.comArea of WorkKey Plan100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 FOURTH FLOORTHIRD FLOORWC-2CO2"FD-1L-2L-2S-1WC-22"FD-1(E)4"1-1/2"1-1/2"1-1/2"2"(E)4"(E)4"(E)4"VVV(E)4"1-1/2"4"2"1-1/2"2"2"1-1/2"VV2"1-1/2"1-1/2"2"(E)4"1-1/2"DF-1(E)4"COCOWC-1WC-2WC-1U-1WC-1WC-2CO2"FD-1COL-2L-1L-11-1/2"1-1/2"2"2"2"V4"4"2"V (E)4"V(E)4"V(E)4"V (E)4"(E)V.T.R(E)4"VFOURTH FLOORTHIRD FLOORCOMS-1L-2L-11-1/2"1-1/2"2"2"1-1/2"1-1/2"VV2"1-1/2"(E)4"WC-1WC-22"2"CO(E)4"2"2"2"2"2"2"(E)4"(E)4"(E)4"(E)4"VVVVVV4"4"4"4"3"(E)4"(E)4"(E)4"(E)4"(E)4"VVVV(E)4"STACK SCALE:DNTSSTACK SCALE:CNTSSTACK SCALE:BNTSSTACK SCALE:ANTSSCALE:2WASTE AND VENT RISER DIAGRAMSNTS2"FD-14"4"4"2"2"1-1/2"L-1L-2L-1L-11/2"1/2"1/2"3/4"3/4"(E)1-1/2"CW(E)1-1/2"HW(E)3/4"HWRSCALE:1DOMESTIC WATER RISER DIAGRAMSNTS(E)2"CWWC-1WC-1WC-2WC-2WC-1U-12"2"1/2"2"1"1"1"1"1"3/4"DF-1(E)1-1/2"CW(E)1-1/2"HW(E)3/4"HWRMS-1L-2L-1L-1WC-2WC-11/2"1/2"3/4"1-1/2"1/2"1/2"1/2"1"1"3/4"1-1/2"S-1L-2WC-2WC-2L-2(E)1-1/2"CW(E)1-1/2"HW1/2"1"1-1/2"3/4"1-1/2"1/2"1/2"1"RISER SCALE:1NTSRISER SCALE:2NTSRISER SCALE:3NTSRISER SCALE:4NTSSVB-11/2"1/2"1/2"ICEREFP3.4PLUMBINGRISER DIAGRAMSD.TOWNSENDD. TOWNSENDDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:43 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\P3-4 - PLUMBING RISER DIAGRAMS.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724 UPUPW.R.R.313M.R.R.312Jan.314SAN SAN SAN SAN CP3.1 CP3.1 7818CO554426CO4"4"3"3"4"4"BP3.1 BP3.1 AP3.1 AP3.1 315189COCO43COCO554446624"4"4"2"2"1-1/2"124UPCP3.1 CP3.1 BP3.1 BP3.1 AP3.1 AP3.1 101211012WC-1WC-1WC-2WC-2WC-1WC-2WC-1U-1DF-111114MS-11311316161915102020202020221616161323C.O.C.O.ST4"ST ST VVVV VV(E)4"(E)4"(E)4"(E)4"2"FD-12"FD-1(E)4"(E)4"L-1L-1L-23P3.1 2P3.1 1P3.1 3P3.1 2P3.1 1P3.1 2524L-1L-1L-21/2"W.R.R.426M.R.R.427Jan.425REF.REF.UPUPM.R.R.331W.R.R.330Kitchenette329Vending328SAN SAN 263545143CO2"4"4"2"4"4"DP3.1 DP3.1 32"UPREF.REF.ICEDP3.1 DP3.1 11WC-22"FD-1WC-22"FD-1L-2L-2116202016171023S-1V VV(E)4"(E)4"(E)4"P3.1 4P3.1 261/2"29SVB-128272"FD-1301/2"R.R.415R.R.416Kitchenette417GENERAL NOTES:A.SANITARY PIPING SHALL BE INSTALLED AT A MINIMUMSLOPE OF 1/8" PER FOOT.B.EXISTING DRYWALL ON THIRD FLOOR RESTROOM CHASEWALLS SHALL BE REMOVED FOR PIPE INSTALLATION.DRYWALL SHALL BE REINSTALLED/ REPLACED AFTERINSTALLATION IS COMPLETE. DRYWALL WORK BY G.C.C.NEW PLUMBING VENTS SHALL CONNECT TO EXISTINGVENT SYSTEM AT VENT STUBS PROVIDED. NO NEWVENT-THRU-ROOF SHALL BE INSTALLED.CODED NOTES:1.EXISTING 4" VENT RISER.2.EXISTING 4" SANITARY RISER.3.2" SANITARY UP TO FLOOR DRAIN.4.4" SANITARY UP TO WATER CLOSET.5.2" VENT UP.6.CONNECT 4" SANITARY TO EXISTING 4" SANITARY STUB.7.3" SANITARY UP TO MOP BASIN.8.2" VENT UP IN WALL ABOVE.9.1-1/2" SANITARY UP TO DRINKING FOUNTAINS.10.EXISTING 4" SANITARY/ VENT RISER.11.EXISTING 4" V.T.R.12.EXISTING 2" COLD WATER RISER. CONNECT 2" COLDWATER TO RISER AND ROUTE 2" COLD WATER HEADERTHRU CHASE. CONNECT 1" COLD WATER FROM HEADERTO EACH OF FIVE (5) WATER CLOSETS, 3/4" COLD WATERTO ONE (1) URINAL AND 1/2" COLD WATER TO DRINKINGFOUNTAINS. SEE DOMESTIC WATER RISER 2.13.CONNECT 2" VENT TO EXISTING 2" VENT STUB.14.2" VENT UP IN WALL FROM BELOW.15.EXISTING 1-1/2" COLD WATER, 1-1/2" HOT WATER AND 3/4"HOT WATER RETURN RISERS. ROUTE 3/4" HOT WATERFROM RISER THRU CHASE AND CONNECT 1/2" HOTWATER TO EACH OF THREE (3) LAVS, ROUTE 1-1/2" COLDWATER THRU CHASE AND CONNECT 1" COLD WATER TOEACH OF TWO (2) WATER CLOSETS AND 1/2" COLDWATER TO EACH OF THREE (3) LAVS. SEE DOMESTICWATER RISER 3.16.1-1/2" SANITARY DOWN, ROUTE THRU CHASE TO 2"SANITARY RISER, 1-1/2" VENT UP TO 2" VENT HEADER.ROUTE 2" VENT HEADER THRU CHASE AND CONNECT TOEXISTING 2" VENT STUB ON EXISTING VENT RISER.17.1-1/2" SANITARY DOWN AND ROUTE THRU WALL TOEXISTING SANITARY RISER. 1-1/2" VENT ROUTE THRUWALL AND CONNECT TO VENT RISER.18.2" SANITARY FROM CHASE ABOVE.19.2" SANITARY DOWN TO FLOOR BELOW.20.2" VENT FROM BELOW CONNECT TO 2" VENT HEADER INCHASE.21.1-1/2" COLD WATER, 1-1/2" HOT WATER AND 3/4" HOTWATER RETURN RISER. ROUTE 3/4" COLD WATER THRUCHASE AND CONNECT 1/2" COLD WATER TO EACH OFTHREE (3) LAVS. ROUTE 3/4" HOT WATER FROM RISERTHRU CHASE AND CONNECT 1/2" HOT WATER TO EACHOF THREE (3) LAVS. SEE DOMESTIC WATER RISER 1.22.2" SANITARY DOWN TO FLOOR BELOW, 2" VENT UP TOVENT HEADER IN CHASE.23.CONNECT 2" SANITARY TO EXISTING 2" SANITARY STUB.24.1/2" HOT AND COLD WATER DOWN IN WALL TO MOP SINK.25.CONNECT 1/2" HOT AND COLD WATER TO EXISTINGRISERS IN CHASE. ROUTE ABOVE CEILING TO MOP SINK.26.1/2" HOT AND COLD WATER DOWN IN WALL TO SINK.27.1/2" COLD WATER DOWN IN WALL AND OUT OF WALL AT+48" A.F.F. FOR ICE MACHINE. PROVIDE VALVED 1/2" MPTSTUB AT OUTLET.28.1/2" COLD WATER DOWN IN WALL TO SHUT-OFF VALVEBOX MOUNTED AT +18" A.F.F. BEHIND REFRIGERATOR.29.CONNECT 1/2" HOT AND COLD WATER TO EXISTINGRISERS IN CHASE AND ROUTE ABOVE CEILING TOKITCHENETTE SINK.30.PROVIDE FUNNEL FOR FLOOR DRAIN. SLAB TO BE COREDRILLED FOR DRAIN INSTALLATION.67456784.3CBCBHIJHIJ67456784.3P4.4PLUMBINGENLARGED PLANSD. TOWNSENDDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:43 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\P4-4 - PLUMBING ENLARGED.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724SCALE:1ENLARGED THIRD FLOOR RESTROOMS1/4"=1'-0"SCALE:2ENLARGED THIRD FLOOR RESTROOMS1/4"=1'-0"2'4'8'0N2'4'8'0NSCALE:3ENLARGED FOURTH FLOOR RESTROOMS1/4"=1'-0"SCALE:4ENLARGED FOURTH FLOOR RESTROOMS/KITCHENETTE1/4"=1'-0"2'4'8'0N2'4'8'0ND. TOWNSEND TYPICAL BRANCH LINEWATER HAMMERARRESTORNOTES:1. PREFERRED INSTALL WATER HAMMER ARRESTORS AT THE END OFBRANCH LINE BETWEEN THE LAST TWO FIXTURES SERVED.2. ONE WATER HAMMER ARRESTOR PER 20' LINE, AND ANOTHER FORBRANCHES OVER 20' IN LENGTH.3. THE SUM OF FIXTURE UNIT RATING OF UNITS OVER 20' IN LENGTHSHALL BE EQUAL TO OR GREATER THAN THE DEMAND OF THEBRANCHES.WATER HAMMER ARRESTOR SCHEDULESUPPLY RISERTYPE INDICATED INPDI SYMBOLFIXTURE UNITRATINGA1-11B12-32C33-60D61-113E114-154F155-330SCHEDULE BELOWPROVIDE HORIZONTAL BRACE FOR PIPE5" AND LARGER AT EVERY BRANCHOPENING OR CHANGE OF DIRECTION BYTHE USE OF BRACES, BLOCKS ORRODDING TO PREVENT MOVEMENT INACCORDANCE WITH CISPI STD.INSULATIONPIPEHANGER RODINSULATION (TYP.)PIPE (TYP.)UNISTRUT CHANNELPROVIDE A SECTION OF HIGHCOMPRESSION STRENGTH INSULATIONAT EACH CLAMP HANGER POINT.INSULATION TO BE FULL ROUNDCONTINUOUS AND EXTEND 2" BEYONDGALV. STEEL SHIELD INSTALLED OVERINSULATION EACH WAY.UNISTRUT BASE PLATE ANCHORED TOCONCRETE FLOOR, OR ENGINEERAPPROVED EQUAL, TYPICAL.HOT AND COLDWATER PIPINGMIN. 1-5/8" UNISTRUT WITHPIPE CLAMPS OR ENGINEERAPPROVED EQUAL, TYPICAL.WASTE AND VENT CHASE PIPINGSUPPORT CONFIGURATIONS.PROVIDE A SECTION OF HIGHCOMPRESSION STRENGTH INSULATIONAT EACH HANGER POINT. INSULATIONTO BE FULL ROUND AND EXTEND 2"BEYOND GALV. SHIELD EACH WAY.GALVANIZED STEEL SHEET SHIELDCLEVIS HANGER FOR SINGLE PIPE RUNSSHIELD FOR PIPE3" AND LARGERGRINNELL FULL PIPE CLAMP NO. 261ANCHORED TO CONCRETE FLOOR AND1-5/8 UNISTRUT, OR ENGINEERAPPROVED EQUAL, TYPICAL.PIPE CLAMP FOR PIPE2-1/2" & SMALLERFOR PIPE 2 1/2" ANDSMALLER1-1/2" VENT, (MIN.)2"x1-1/2"NIBCO TYPE 604ADAPTORESCUTCHEONOR EQUALHEAVY LAVATORY SUPPLY KIT: HEAVY ANGLE STOPHANDLES AND HEAVY VALVE W/ LOOSE KEY CHROMEPLATED COPPER SUPPLIES. PROVIDE INSULATEDCOVERS FOR ADA SINK.SUMMER POSIFIX SUPPORT BRACKETSOR ENGINEER APPROVED EQUAL.TYPE "L" COPPER PIPEOR PEX-A FOR H & CW2" WASTE, (MIN.),FOR LOCATIONAND ROUTING OFWASTE, VENT &WATER PIPINGREFER TO PLANSA.D.A. SINK OFFSET,LOCATE P-TRAP TO PROVIDE FORMIN. KNEE CLEARANCE OF 8"(PERA.D.A.).P-TRAP. FOR A.D.A. SINK INSULATEALL EXPOSED SINK WASTE ANDWATER OUTLET PIPING AND STOPVALVES, AS PER SPECIFICATIONS.ESCUTCHEON W/ SET SCREW, (TYP.AT WASTE AND WATER WALLPENETRATIONS).WALLCONSTRUCTION(REFER TO ARCHDWG'S).DRAIN PIPING.GRIDSTRAINER6" (MIN.) 6" (MIN.)COUPLING ASREQUIRED(TYP.)CARRIER PIPE (TYP.)METALLIC PIPEPIPE INSULATION AS REQUIRED (TYP.)INSULATION SHALL BE PROVIDEDWITH THE SAME PERFORMANCE ASTHE FIRESTOPPING MATERIALSTEEL PIPE SLEEVEMASONRY WALL OR FLOOR SLABNOTE: PIPE SLEEVE SHALL BE SIZED TO PROVIDE1/4" ALL AROUND CLEARANCE. INSULATED ORNON-INSULATED, ABOVE GRADE.P5.4PLUMBINGDETAILSD. TOWNSENDDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:43 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\P5-4 - PLUMBING DETAILS.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724SCALE:3DETAIL - PIPE HANGER AND SUPORRTSN.T.S.SCALE:1DETAIL - PIPE SLEEVEN.T.S.SCALE:2DETAIL - LAVATORY PIPINGN.T.S.SCALE:4DETAIL - PIPE RESTRAINTN.T.S.SCALE:5DETAIL - WATER HAMMER ARRESTORN.T.S.D. TOWNSEND PLUMBING FIXTURE ROUGH-IN SCHEDULEFIXTUREWASTETRAPVENTCOLDHOTTEMPEREDWC-1, 24" INTEGRAL2"1"N/AN/AU-12" INTEGRAL1-1/2"3/4"N/AN/AL-1, 21-1/2"1-1/4"x1-1/2"1-1/2"1/2"1/2"N/AMS-13"3"1-1/2"1/2"1/2"N/ADF-11-1/2"1-1/4"x1-1/2"1-1/2"1/2"N/AN/AS-11-1/2"1-1/2"x1-1/2"1-1/2"1/2"1/2"N/APLUMBING SPECIALTIES SCHEDULETAGFIXTURE DESCRIPTIONMANUFACTURERMODEL #FD-1ADJUSTABLE CAST IRON BODY, ROUND NICKEL BRONZE STRAINER. CAULK OUTLET. PROVIDE TRAP SEAL LIKE MIFAB "MI-GUARD" IN-LIEU OF TRAP PRIMER.J.R. SMITH2005-APLUMBING FIXTURE SCHEDULETAGFIXTURE DESCRIPTIONMANUFACTURERMODEL #WC-1FIXTURE: VITREOUS CHINA, FLOOR MOUNTED ELONGATED BOWL, 1-1/2" INLET TOP SPUD, LOW-CONSUMPTION 1.28 GPF, DIRECT-FED SIPHON JET ACTION, FULLY-GLAZED 2-1/8" TRAPWAY, 10"x12" WATER, SURFACE AREA, MEETSASME FLUSH REQUIREMENTS AT 1.28 GPF.TOTOCT705ENGFLUSH VALVE: DIAPHRAGM TYPE FLUSH VALVE, CHROME PLATED, SYNTHETIC RUBBER DIAPHRAGM, INFRARED SENSOR, THREE SECOND FLUSH DELAY, OVERRIDE BUTTON, ADJUSTMENT SCREW, 1” I.P.S. SCREWDRIVER ANGLESTOP, VACUUM BREAKER FLUSH CONNECTION, SPUD COUPLING AND FLANGE FOR 1-1/2” TOP SPUD, SWEAT SOLDER ADAPTER AND CAST SET SCREW WALL FLANGE, LOW CONSUMPTION 1.28 GPF.OWNER FURNISHEDN/ASEAT: HEAVY WEIGHT AND INJECTION-MOLDED OF SOLID PLASTIC, OPEN FRONT LESS COVER FOR ELONGATED BOWL AND FEATURE EXCLUSIVE, FOUR LARGE MOLDED-IN BUMPERS, CONCEALED CHECK HINGES WITH STAINLESSSTEEL POSTS.CHURCH295CTWC-2FIXTURE: ADA COMPLIANT, VITREOUS CHINA,FLOOR MOUNTED ELONGATED BOWL, 1-1/2" INLET TOP SPUD, LOW-CONSUMPTION 1.28 GPF, DIRECT-FED SIPHON JET ACTION, FULLY-GLAZED 2-1/8" TRAPWAY, 10"x12" WATER,SURFACE AREA, MEETS ASME FLUSH REQUIREMENTS AT 1.28 GPF.TOTOCT705ELNGFLUSH VALVE: DIAPHRAGM TYPE FLUSH VALVE, CHROME PLATED, SYNTHETIC RUBBER DIAPHRAGM, INFRARED SENSOR, THREE SECOND FLUSH DELAY, OVERRIDE BUTTON, ADJUSTMENT SCREW, 1” I.P.S. SCREWDRIVER ANGLESTOP, VACUUM BREAKER FLUSH CONNECTION, SPUD COUPLING AND FLANGE FOR 1-1/2” TOP SPUD, SWEAT SOLDER ADAPTER AND CAST SET SCREW WALL FLANGE, LOW CONSUMPTION 1.28 GPF.OWNER FURNISHEDN/ASEAT: HEAVY WEIGHT AND INJECTION-MOLDED OF SOLID PLASTIC, OPEN FRONT LESS COVER FOR ELONGATED BOWL AND FEATURE EXCLUSIVE, FOUR LARGE MOLDED-IN BUMPERS, CONCEALED CHECK HINGES WITH STAINLESSSTEEL POSTS.CHURCH295CTU-1FIXTURE: ADA COMPLIANT, VITREOUS CHINA, WALL HUNG, HIGH EFFICIENCY 0.125 GPF, FLUSHING RIM, ELONGATED 14" RIM FROM FINISHED WALL, WASHOUT FLUSH ACTION, EXTENDED SIDES FOR PRIVACY, 3/4" INLET TOPSPUD, OUTLET CONNECTION THREADED 2" INSIDE , MEETS ASME FLUSH REQUIREMENTS AT 0.125 GPF. STAINLESS STEEL STRAINER.TOTOUT445UFLUSH VALVE: DIAPHRAGM TYPE FLUSH VALVE, CHROME PLATED, SYNTHETIC RUBBER DIAPHRAGM, INFRARED SENSOR, THREE SECOND FLUSH DELAY, OVERRIDE BUTTON, FOUR SIZE AA BATTERIES, “LOW BATTERY” FLASHINGLED, INFRARED SENSOR RANGE ADJUSTMENT SCREW, 3/4” I.P.S. SCREWDRIVER ANGLE STOP, VACUUM BREAKER FLUSH CONNECTION, SPUD COUPLING AND FLANGE FOR 3/4" TOP SPUD, SWEAT SOLDER ADAPTER AND CAST SETSCREW WALL FLANGE, LOW CONSUMPTION 0.125 GPF.OWNER FURNISHEDN/ACARRIER: WALL URINAL SUPPORT WITH TOP SUPPORT PLATE, RECTANGULAR STEEL UPRIGHTS WITH WELDED FEET, ADJUSTABLE SUPPORT PLATE AND MOUNTING FASTENERS.ZURNSERIES Z1200L-1FIXTURE: VITREOUS CHINA UNDER MOUNT LAVATORY, RECTANGULAR 17" X 13" WITH FRONT OVERFLOW AND CENTER 1-1/4" DRAIN. WHITE COLORTOTOLT221FAUCET: 0.5 GPM SENSOR FAUCET. FURNISHED BY OWNER; CONTRACTOR INSTALLEDOWNER FURNISHEDN/ATRIM: SUPPLY PIPE WITH LOOSE KEY STOPS. CAST BRASS P-TRAP WITH CLEAN-OUT. DRAIN WITH CHROME PLATED CAST BRASS GRID STRAINER. CHROME PLATED BRASS 17 GAUGE TAILPIECE.MCGUIRE165LK, 8902, 149THEMOSTATIC MIXING VALVE: LEAD-FREE DESIGN, WAX-FILLED THERMOSTAT, ADJUSTABLE SET POINT WITHIN TEMPERATURE RANGE, UNIVERSAL MOUNTING CAPABILITY, INTEGRAL CHECK VALVES AND STRAINER, ASSE 1070COMPLIANT. SET TO 110°F.BRADLEYS59-4000L-2FIXTURE: ADA COMPLIANT, VITREOUS CHINA UNDER MOUNT LAVATORY, RECTANGULAR 17" X 13" WITH FRONT OVERFLOW AND CENTER 1-1/4" DRAIN. WHITE COLORTOTOLT221FAUCET: 0.5 GPM SENSOR FAUCET. FURNISHED BY OWNER; CONTRACTOR INSTALLEDOWNER FURNISHEDN/ATRIM: SUPPLY PIPE WITH LOOSE KEY STOPS. CAST BRASS P-TRAP WITH CLEAN-OUT. DRAIN WITH CHROME PLATED CAST BRASS GRID STRAINER. PLUG. CHROME PLATED BRASS 17 GAUGE TAILPIECE. PROVIDE LAV INSULATIONON SUPPLY AND DRAIN PIPINGMCGUIRE165LK, 8902, 149THEMOSTATIC MIXING VALVE: LEAD-FREE DESIGN, WAX-FILLED THERMOSTAT, ADJUSTABLE SET POINT WITHIN TEMPERATURE RANGE, UNIVERSAL MOUNTING CAPABILITY, INTEGRAL CHECK VALVES AND STRAINER, ASSE 1070COMPLIANT. SET TO 110°F.BRADLEYS59-4000MS-1FIXTURE: 24"x24", PRECAST TERRAZZO ONE PIECE PRODUCTS ARE MADE OF MARBLE CHIPS CAST IN GREY PORTLAND CEMENT. 12" HIGH. SHOULDERS SHALL NOT BE LESS THAN 2" WIDE WITH 1/2" PITCH TOWARD INSIDE.STAINLESS STEEL CAPS ON ALL CURBS. DRAIN BODY MADE OF STAINLESS STEEL CAST INTEGRALLY AND PROVIDE FOR A CAULKED LEAD CONNECTION NOT LESS THAN 1" DEEP TO A 3" PIPE. COORDINATE HANDING OF MOP SINKWITH DRAWINGS. PROVIDE STAINLESS STEEL PANELS ON EACH WALL THAT ABUTS MOP SINK. PROVIDE MOP HANGER WITH (3) CLAMPS FOR (3) MOPS, PROVIDE 5' LONG HOSE WITH HOSE CLAMP HANGERFLORESTONEMODEL 82TRIM: WALL MOUNTED SERVICE SINK FAUCET, POLISHED CHROME PLATED FINISH, SOLID BRASS BODY CONSTRUCTION, ATMOSPHERIC VACUUM BREAKER SPOUT WITH PAIL HOOK AND WALL BRACE, 3/4" MALE GARDEN HOSETHREAD OUTLET, LEVER HANDLES WITH SECURED COLOR CODED INDEX BUTTONS.OWNER FURNISHEDN/ADF-1FIXTURE: WALL HUNG, ADA COMPLIANT, DUAL LEVEL, NON-REFRIGERATED, DRINKING FOUNTAIN. FRONT MOUNTED PUSH BUTTON. BUBBLER WITH CHROME PLATED BRASS BUBBLER, FLOW REGULATOR, DRAIN AND TRAPASSEMBLY. WALL PANEL AND MOUNTING BRACKET. 14 GAUGE TYPE 304 STAINLESS STEEL WITH SATIN FINISH.ELKAYEHWM217CTRIM: SUPPLY PIPE WITH LOOSE KEY STOPS. CAST BRASS P-TRAP WITH CLEAN-OUT. DRAIN WITH CHROME PLATED CAST BRASS SOLID TOP,MCGUIRE165LK, 8902S-118-1/2"x 18-1/2" x 9" DEEP, SINGLE BOWL, #18 GAUGE, TYPE 304 NICKEL BEARING STAINLESS STEEL. UNDERMOUNT. 9/16" VERTICAL AND HORIZONTAL RADIUS.FULLY UNDERCOATED TO DAMPEN SOUND AND PREVENT CONDENSATION. 3-1/2" DRAIN OPENING LOCATED OFF-CENTER REAR, 3 HOLES, 8" CENTERS.ELKAYECTRU17179DECK MOUNTED 8" WIDESPREAD FAUCET, POLISHED CHROME PLATED FINISH, SOLID BRASS BODY CONSTRUCTION, 8" CENTERS, 8" SWING SPOUT, 0.5 GPM PRESSURE COMPENSATING AERATOR OUTLET, WING METAL HANDLESAND SECURED COLOR CODED INDEX BUTTONS.OWNER FURNISHEDN/ADRAIN WITH NICKEL PLATED BRASS BODY WITH GRID STRAINER, POLISHED FINISH.ELKAYLK18TRIM: SUPPLY PIPE WITH LOOSE KEY STOPS. CAST BRASS P-TRAP WITH CLEAN-OUT. P.O. PLUG. CHROME PLATED BRASS 17 GAUGE TAILPIECE.MCGUIRE165LK, 8912SVB-120 GAUGE RECESSED REFRIGERATOR BOX WITH 18 GAUGE FACEPLATE. PAINT TO MATCH WALL. VALVE SHALL BE 1/2" SWEAT CONNECTION AND 1/4" O.D.GUY GRAYMIB1HAP6.4PLUMBINGSCHEDULESD. TOWNSENDDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:43 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\P6-4 - PLUMBING SCHEDULES.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724D. TOWNSEND TO SPRINKLERSINSPECTOR'S TEST VALVESIGHT GLASSFLOW SWITCHNOTE:INSPECTOR'S TEST VALVES SHALL BE INSTALLEDIN ACCESSIBLE LOCATION. MOUNT ADJACENT TOFIXED STRUCTURE IF LADDER ACCESS ISREQUIRED.UNION WITH CORROSION RESISTANTORIFICE GIVING FLOW EQUIVALENT TOTHE SMALLEST SPRINKLER IN THE SYSTEMAUXILIARY DRAIN VALVEINDICATING TYPE FLOORCONTROL VALVE WITHSUPERVISORY SWITCHFIRE PROTECTIONSUPPLY MAINROUTE TO THE TEST DRAIN RISERFSPSPHWFGEDTUVRSCBAONMILKHDGPMHPHGTHZHEADGALLONS PER MINUTEHEIGHTHORSEPOWERHERTZVOLTWEIGHTWATER GAUGEWATERSUPERVISED WALL POST INDICATOR VALVEVWGTWGWWPIVDOUBLE CHECK DETECTOR ASSEMBLYFIN FL EL°FEXPFDCFEXISTGAFVCFPGALFTEXISTINGEXPANSIONDEGREES FAHRENHEITFIRE DEPARTMENT CONNECTIONFIRE PROTECTION WATER SUPPLYGAUGEFINISHED FLOOR ELEVATIONFIRE VALVE CABINETFIRE PROTECTIONGALLONSFOOT OR FEETDNDIADWGEQUIPELDEPTDCDADCU FTCONTCU INDIAMETERDOWNDRAWINGEQUIPMENTELEVATIONDEPARTMENTCONTINUATIONCUBIC FEETCUBIC INCHDRAINSTANDARDSPECIFICATIONSTRAINERSHEETTOP ELEVATIONTYPICALUNLESS NOTED OTHERWISESTDSTRSPECSHTTETYPUNOPRESSURE REDUCING VALVEPSI GAUGEPOUNDS PER SQUARE INCHPRESSUREREVOLUTIONS PER MINUTESECONDPRESSPSIGPRVPSIRPMSECABBREVIATIONSAVGAUTOBFVBOPBLDGCAPAVERAGEAUTOMATICBUTTERFLY VALVEBUILDINGBOTTOM OF PIPECAPACITYAPPROXABVAFFAMPABOVEABOVE FINISHED FLOORAPPROXIMATEAMPERENUMBERNOT TO SCALEOWNER FURNISHED, CONTRACTOR INSTALLEDNOT IN CONTRACTNORMALLY OPENMAXIMUMNOT APPLICABLEMINIMUMNORMALLY CLOSEDNO.NTSOFCINICNOMAXN/AMINNCINCHESPOUNDSKILOWATTLENGTHLINEAR FEETINKWLBLGLFARCHITECTBFBELOW FLOORCONNCONNECTION OR CONNECTFSFLOW SWITCHHVACHEATING, VENTILATING AND AIR CONDITIONINGMECHMECHANICALMFGMANUFACTURERPLBGPLUMBINGPSPRESSURE SWITCHSTSTLSTAINLESS STEELTOPTOP OF PIPEARCHGENERAL NOTESA. COORDINATE EXACT REQUIREMENTS AND LOCATION OF WORK WITH THE WORK OF OTHER TRADES PRIOR TO FABRICATION. PROVIDE ADDITIONAL OFF-SETS AND SECTIONS OF PIPINGAS MAY BE REQUIRED TO MEET THE APPLICABLE JOB CONDITION REQUIREMENTS. VERIFY EXISTING JOB-SITE ELEVATIONS, DIMENSIONS, AND CONDITIONS, PRIOR TO FABRICATION ORINSTALLATION OF THE WORK. COORDINATE EXACT ROUTING OF PIPING WITH OTHER TRADESSO THAT NO CONFLICTS OCCUR WITH DUCTWORK, PIPING, LIGHTS, STRUCTURE, ETC.B. VISIT THE SITE OF THE WORK AND DETERMINE AN EXACT KNOWLEDGE OF CONDITIONS AFFECTING THE EXECUTION OF WORK. AFTER VISITING THE SITE, REQUEST SUCH FURTHERINFORMATION AND/OR CLARIFICATIONS AS NECESSARY TO FULLY UNDERSTAND THE WORKREQUIRED AND TO PROPERLY ESTIMATE COSTS. THE RENDERING OF A PROPOSAL OR BID TOPERFORM THE WORK SHALL REPRESENT THAT THE SITE HAS BEEN VISITED AND ALL CONDITIONS AFFECTING PERFORMANCE OF THE CONTRACT HAVE BEEN NOTED.C. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT AND COMPLETELY PACKED WITH FIRE STOP MATERIAL BY TRADE CONTRACTORS.D. COORDINATE THE LOCATION OF ALL UTILITY CONNECTION POINTS FOR EQUIPMENT WITH OTHER TRADES.E. THE CONTRACTOR IS TO VERIFY THE EXACT SERVICE OF ANY EXISTING PIPING PRIOR TO INSTALLING ANY NEW CONNECTIONS. ANY DISCREPANCIES BETWEEN THE CONSTRUCTION DOCUMENTS OR THE DESIGN INTENT AND ACTUAL CONDITIONS ARE TO BE BROUGHT TO THEATTENTION OF THE ENGINEER IMMEDIATELY, PRIOR TO INSTALLING SAID CONNECTION.F. PROVIDE WET PIPE SPRINKLER SYSTEM FOR THIS AREA OF WORK. PROVIDE ALL NECESSARYCOMPONENTS FOR FULLY OPERATIONAL WET PIPE SPRINKLER SYSTEM. ALL SHUT OFF VALVES IN THE SPRINKLER SYSTEM ARE TO BE ELECTRICALLY SUPERVISED. DESIGN AND INSTALL FIRE PROTECTION SYSTEM IN ACCORDANCE WITH NFPA 13, STATE REQUIREMENTSAND LOCAL AUTHORITY HAVING JURISDICTION.G. PER THE ELEVATOR MEETING THE REQUIREMENTS OF NFPA 13, PARAGRAPHS 8.15.5.2 AND 8.15.5.5, NO SPRINKLERS SHALL BE PROVIDED IN THE ELEVATOR SHAFT.H. SPRINKLERS SHALL BE CENTERED IN CEILING TILES WHERE LAY-IN CEILINGS ARE PRESENT.FLOW TEST INFORMATIONFLOW TEST LOCATION MAPFPCFIRE PROTECTION CONTRACTORTAMPER SWITCHTSNOTE: NOT ALL ABBREVIATIONS MAY BE USED.NOTE: NOT ALL SYMBOLS MAY BE USED.(E)(D)FIRE(A)SYMBOLS LISTPIPINGEXISTING TO REMAINEXISTING TO BE DEMOLISHEDFIRE PROTECTIONPIPING (FITTINGS, VALVES, AND MISCELLANEOUS)DROPRISETEECAPFLOW ARROWBUTTERFLY VALVEBALL VALVECHECK VALVESTRAINERUNIONPIPE SLEEVEPRESSURE REDUCING VALVEEXISTING ABANDONEDGATE VALVE OR GENERAL SERVICE VALVEGLOBE VALVESOLENOID VALVESUPERVISED VALVEOUTSIDE STEM & YOKE VALVEDOUBLE DETECTOR CHECK ASSEMBLYPRESSURE GAUGE WITH STOPCOCKFLOW SWITCHPRESSURE SWITCHUPRIGHT SPRINKLERPENDANT OR CONCEALED SPRINKLERSIDEWALL SPRINKLERDRY-PIPE BARREL SIDEWALL SPRINKLERFIRE DEPARTMENT CONNECTION92 PSI70 PSI1405 GPMAB01/16/2015CARMEL WATER DEPT.SUPPLY PRESSURE:FLOW PRESSURE:HYDRANT FLOW:FLOW HYDRANT:PRESSURE HYDRANT:TEST DATE:TEST BY:111TH STREETPENNSYLVANIA STREET PENNSYLVANIA STREET111TH STREETHYDRANT "A'(FLOW HYDRANT)HYDRANT "B'(PRESSURE HYDRANT)N.T.S.SNFIRE PROTECTION AREASPRINKLER TYPES PER LOCATION.REFER TO SPECIFICATIONS FORTO SUITLENGTHPROVIDETO SUITLENGTHPROVIDE40 PIPING, TYPICAL1" BLACK STEEL SCHEDULESUSPENDED CEILINGCHROME ESCUTCHEON PLATE1" X 1/2" PIPE REDUCING COUPLINGSPRINKLER BRANCH PIPINGSUSPENDED CEILINGCHROME ESCUTCHEON PLATEREFER TO SPECIFICATIONS FORSPRINKLER TYPES PER LOCATION.1"X1/2" PIPEREDUCING COUPLINGBRANCH LINE40 PIPING, TYPICAL1" BLACK STEEL SCHEDULEUPRIGHT SPRINKLERSTRUCTURE ABOVENOTE: DEFLECTOR TO BEALIGNED PARALLEL TOSTRUCTURE ABOVE, LOCATED4" TO 12" BELOW STRUCTURE.REDUCING TEEF0.4FIRE PROTECTIONGENERALINFORMATIONJ. LEED. TOWNSENDDateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:42 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\F0-4 - FIRE PROTECTION GENERAL INFORMATION.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.com100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724SCALE:1DETAIL - EXISTING FIRE PROTECTION FLOOR CONTROLN.T.S.SCALE:3DETAIL - FIRE PROTECTION ARM OVERN.T.S.SCALE:2DETAIL - UPRIGHT SPRINKLERN.T.S. SUPAABBCCDDEEFFGGHHIIJJ1122334455667788X3X44.3A.4A.4H.8UP132OH-1OH-1OH-1OH-1LHLHLHLHLHLHLHLH4ElevatorELEV 2ElevatorELEV 1StairSTR 1StairSTR 2Office434Office433Office432Elevator Lobby401Work Area/Storage423Office430R.R.415R.R.416IT/Elec413Storage414Office412Office411Office410Vault418Office406Office405Office419Office420Office404Office403Office421Office409Office408Office407W.R.R.426M.R.R.427Jan.425Office424IDF428Meeting431Internal Controls435Restroom Corridor429CustomerSolutions422Kitchenette417Accounting/Financial402F1.4FOURTH FLOORFIRE PROTECTIONPLAND. TOWNSENDD. TOWNSENDFIRE SPRINKLER HAZARD CLASS:LIGHT HAZARD - .10 GFM/SF OVER BASE AREA OF1,500 SF. MAXIMUM SPRINKLER COVERAGE AREAOF 225 SF. HOSE DEMAND OF 100 GPM. ALLAREAS ARE LIGHT HAZARD UNLESS OTHERWISENOTED.ORDINARY HAZARD GROUP - 1 - .15GFM/SF OVERBASE AREA OF 1,500 SF. MAXIMUM SPRINKLERCOVERAGE OF 130 SF. HOSE DEMAND OF 250 GFM.LHOH-1DateDrawn By:Checked By:Project Number:Delta FaucetFourth Floor Fit-Out9/30/2016 11:42 AM No.DateDescription55 East 111th StreetIndianapolis, IN 46280Project NameSheet TitleSheet NumberRevisionsSealSignatureThis drawing and all information on it is the property of ArchituraCorporation. It is confidential and its submission or distribution tomeet official regulartory requirements or for other purposes inconnection with this project is not to be construed as publication inderogation of common law copyright or other reserved rights. Thisdrawing nor any part of it nor any information concerning it maybe copied, exhibited, reproduced or furnished to others nor mayphotographs be made of any article fabricated or assembled fromthis drawing without written consent of Architura Corporation.© Copyright 2015 Architura CorporationP:\2016 PROJ\16-130-02 DELTA FAUCET - 4TH FLOOR BUILD-OUT\CAD\CAD SHEETS\F1-4 - FOURTH FLOOR FIRE PROTECTION PLAN.DWG Architura Corporation55 Monument Circle Suite 1212Indianapolis, IN 46204(317) 348-1000(317) 951-1213 faxwww.archituracorp.comArea of WorkKey Plan100% Bid Set10/03/201616113200 South Rangeline Road,Suite 213Carmel, IN 46032(317) 573-22228606 Allisonville Road,Suite 270Indianapolis, IN 46250(317) 413-5724SCALE:1FOURTH FLOOR FIRE PROTECTION PLAN1/8"=1'-0"4'8'16'0NGENERAL NOTES:A. PROVIDE A WET PIPE SPRINKLER SYSTEM FOR THISBUILDING. PROVIDE ALL NECESSARY COMPONENTSFOR FULLY OPERATIONAL WET PIPE SPRINKLERSYSTEM. ALL SHUT OFF VALVES IN THE SYSTEMARE TO BE ELECTRONICALLY SUPERVISED. DESIGNAND INSTALL FIRE PROTECTION SYSTEM IN ACCORDANCE WITH NFPA 13, STATE REQUIREMENTS AND LOCAL AUTHORITY HAVINGJURISDICTION.B. COORDINATE EXACT REQUIREMENTS AND LOCATIONOF WORK WITH THE WORK OF OTHER TRADES PRIORTO FABRICATION. PROVIDE ADDITIONAL OFF SETSAND THE SECTION OF PIPING AS MAY BE REQUIREDTO MEET APPLICABLE JOB CONDITION REQUIREMENTS. VERIFY BUILDING DIMENSIONS ANDELEVATIONS PRIOR FABRICATION. COORDINATE EXACT ROUTING OF PIPING WITH OTHERTRADES SO THAT NO CONFLICTS OCCUR WITH DUCTWORK, PIPING, LIGHTING, STRUCTURE, ETC.CODED NOTES:1. EXISTING COMBINATION STANDPIPE FIRE RISER.2. EXISTING STANDPIPE RISER.3. EXISTING FLOOR ZONE CONTROL VALVE ASSEMBLY.4. MODIFY EXISTING UPRIGHT SPRINKLERS ON THISFLOOR PER NEW WALL LAYOUT, CEILING GRID ANDCEILING ELEMENTS. PROVIDE NEW ARM-OVERS ANDSPRINKLERS AS REQUIRED TO PROVIDE FULL COVERAGE. SPRINKLERS SHALL MATCH LOWER FLOORS PER DELTA'S STANDARD SPRINKLER TYPE.SPRINKLERS SHALL BE INSTALLED CENTERED INCEILING TILES WHERE LAY-IN CEILINGS ARE PRESENT.