HomeMy WebLinkAbout0005.01 Energy CertificateSICIHjU111LIEI
BUILDING FILE REPORT
Builder's -File: CLARE2903LG Date: January 032000 Page 1
Builder Information
Home --Builder Name:
Davis Homes
Model Name or Number:
Claremont
Development Name:
EMERALD CREST
Property. Address, 5747 AQUAMARINE
DRIVE Lot # 83
Energy Analysis Info
InsulationContractor Name:
Overhead Door Insul. Div.
Telephone Number:
(317)842-7444-
Building Plan Dater
12/31/97
General Design Characteristics
House -Type:
Two Stories
Foundation Type:
Slab
Conditioned Floor Area:
2747.00
Number of Bedrooms:
4
Conditioned Floor -Area Over Garages
11.00 %'Of Total Floor Area
Heated
First
Mid
Second
Third
Basement
Level
Level
Level
Level-
Distribution of Cond Floor Area(%)
51:0
49:0
I
Heated'
First
Mid
Second
Third
Characteristics of Each Floor
Basement
Level
Levef
Level
Level
Number of Corners
8
8
PercentOpen:to Floor Above
30.0
0.0-
Nominal Flat Ceiling Height
8.0
8.0
PercentCatbedralCeiling
0:0
0.0
Schuller International; Inc. Building Insulation Division P.O: Box5108-Denver, CO.802175108:
For. information'on.the Performance Home Total.Insulatlon.System,, ca11.1.4M6543tO3..
This Information doesnot constitute any warranty of energy cost or savings.
REM/Gold v2.33 (c)1996 Architectural Energy Corporation, Boulder, CO.
BUILDING FILE REPORT
CLARE290.BLG
Building Envelope Characteristics
Insulation Level
Baseline
Ceiling(Attic Atiove):
38.0
Cathedral Ceiling:
38.0
Rim/Band Joist`
13.0
Frame Wall(Frame Cavity):
13.0
Frame Wall (Continuous):
4.4
Masonry Wall:
0.0
Foundation Wall(Cavity):
0.0
Foundation Wall(Continous):
10.0
Frame Floor:
19.0
Duct:
FLEX DUCT R-5
Infiltration Rate(ACH):
0.75
Wall Construction Type: Frame
Window Type
Double - Vinyl
Window U-Value:
0.46
Window SHGC:
0.57
Window Area(excluding fnd walls): 351.0 square feet
Number of Non -Glass Exterior Doors: 0
Average Slab Depth Below'Grade
Basement: 0.0
First Level: 1.0
Page 2
Mechanical Systems Characteristics
Heating System Type:
Fuel -Fred air distribution
Heating Fuel Type:
Gas
Cooling System Type:
Air conditioner
Duct Location:
Attic -under insul
Domestic Hot Water Fuel Tvoe:
Gas
Schuller International, Inc.. Building Insulation Division P.O. Box 5108 Denver, CO 80217-5108,
For Information on the Performance Home Total Insulation System, call 1400-654-3103.
This information does not constitute any warranty of energy cost or savings.
REWGold v2.33 (c)1996 Architectural Energy Corporation, Boulder, CO.
0
1993 MEC O\'ERALt Btl LDING tfo COMPLIANCE
Date:
January 03 200G
Home Builder:
Davis Homes
Model Name or Number:
Claremont
Insulation Contractor:
Overhead Door Insul. Div
Contractor's Telephone:
(317)842-7444
Elements
Roofs/Ceilings(U-Value)
Above -Grade Walls (U-Value):
Floors Over Garage (U-Value):
Basement Walls (U-Value):
ICI•HIUILILIEIR
BtiildingFHe:
CLARE290:EILG
Weather Site:
Indianapolis, IN
Degree -Days, H/G:
565-3/378
Energy Costs:
Indiana Gas
Insulation Levels
1993 MEC
As Designed
0.028
0,025
0.131
0.107
0.050
0.046
0.088
0.081
OVERALL Uo: 0.090 0.075
This home meets the overall thermal performance requirements.of the 1993 Model Energy Code
based on 5653 heating degree-days. (Section 502, Model Energy Code, 1993 edition).
Building Elements
Roof/Ceilings
Roof
Above-GradeWalls
Wall
Joist
Window
Window
Window
Frame Floors Over Garage
Floor
Basement Walls
Wall
Cavity Ins.
Contin. Ins
Frame
R-Value
R `✓alue
Spacing
Uo
Area
38.0
0.0
24.0" o.c.
0:025-
1703.1
13.0
4.4
Wood, 2x4, 16" o.c.
0.057
2345.9
13.0
0,0
n/a
0,061
169.8
n/a
n/a
n/a
0.460-
87.8
n/a
n/a
n/a
0.460
87.8
n/a
n/a
n/a
0.460
175.5
19.0
n/a
16.0" o.c.
0.048
302.2
0.0
10.0
None
0.081
169.8
Schuller International, Inc. Building Insulation Division P.O. Box 5106 Denver, CO 80217-5108.
For Information on the Performance Home Total Insulation System, call 1-500-6543103.
This information does not constitute any warranty of energy cost or savings.
REM/Gold v 33(c)1996 Architectural Energy Corporation,. Boulder, CO.