Loading...
HomeMy WebLinkAbout0005.01 Energy CertificateSICIHjU111LIEI BUILDING FILE REPORT Builder's -File: CLARE2903LG Date: January 032000 Page 1 Builder Information Home --Builder Name: Davis Homes Model Name or Number: Claremont Development Name: EMERALD CREST Property. Address, 5747 AQUAMARINE DRIVE Lot # 83 Energy Analysis Info InsulationContractor Name: Overhead Door Insul. Div. Telephone Number: (317)842-7444- Building Plan Dater 12/31/97 General Design Characteristics House -Type: Two Stories Foundation Type: Slab Conditioned Floor Area: 2747.00 Number of Bedrooms: 4 Conditioned Floor -Area Over Garages 11.00 %'Of Total Floor Area Heated First Mid Second Third Basement Level Level Level Level- Distribution of Cond Floor Area(%) 51:0 49:0 I Heated' First Mid Second Third Characteristics of Each Floor Basement Level Levef Level Level Number of Corners 8 8 PercentOpen:to Floor Above 30.0 0.0- Nominal Flat Ceiling Height 8.0 8.0 PercentCatbedralCeiling 0:0 0.0 Schuller International; Inc. Building Insulation Division P.O: Box5108-Denver, CO.802175108: For. information'on.the Performance Home Total.Insulatlon.System,, ca11.1.4M6543tO3.. This Information doesnot constitute any warranty of energy cost or savings. REM/Gold v2.33 (c)1996 Architectural Energy Corporation, Boulder, CO. BUILDING FILE REPORT CLARE290.BLG Building Envelope Characteristics Insulation Level Baseline Ceiling(Attic Atiove): 38.0 Cathedral Ceiling: 38.0 Rim/Band Joist` 13.0 Frame Wall(Frame Cavity): 13.0 Frame Wall (Continuous): 4.4 Masonry Wall: 0.0 Foundation Wall(Cavity): 0.0 Foundation Wall(Continous): 10.0 Frame Floor: 19.0 Duct: FLEX DUCT R-5 Infiltration Rate(ACH): 0.75 Wall Construction Type: Frame Window Type Double - Vinyl Window U-Value: 0.46 Window SHGC: 0.57 Window Area(excluding fnd walls): 351.0 square feet Number of Non -Glass Exterior Doors: 0 Average Slab Depth Below'Grade Basement: 0.0 First Level: 1.0 Page 2 Mechanical Systems Characteristics Heating System Type: Fuel -Fred air distribution Heating Fuel Type: Gas Cooling System Type: Air conditioner Duct Location: Attic -under insul Domestic Hot Water Fuel Tvoe: Gas Schuller International, Inc.. Building Insulation Division P.O. Box 5108 Denver, CO 80217-5108, For Information on the Performance Home Total Insulation System, call 1400-654-3103. This information does not constitute any warranty of energy cost or savings. REWGold v2.33 (c)1996 Architectural Energy Corporation, Boulder, CO. 0 1993 MEC O\'ERALt Btl LDING tfo COMPLIANCE Date: January 03 200G Home Builder: Davis Homes Model Name or Number: Claremont Insulation Contractor: Overhead Door Insul. Div Contractor's Telephone: (317)842-7444 Elements Roofs/Ceilings(U-Value) Above -Grade Walls (U-Value): Floors Over Garage (U-Value): Basement Walls (U-Value): ICI•HIUILILIEIR BtiildingFHe: CLARE290:EILG Weather Site: Indianapolis, IN Degree -Days, H/G: 565-3/378 Energy Costs: Indiana Gas Insulation Levels 1993 MEC As Designed 0.028 0,025 0.131 0.107 0.050 0.046 0.088 0.081 OVERALL Uo: 0.090 0.075 This home meets the overall thermal performance requirements.of the 1993 Model Energy Code based on 5653 heating degree-days. (Section 502, Model Energy Code, 1993 edition). Building Elements Roof/Ceilings Roof Above-GradeWalls Wall Joist Window Window Window Frame Floors Over Garage Floor Basement Walls Wall Cavity Ins. Contin. Ins Frame R-Value R `✓alue Spacing Uo Area 38.0 0.0 24.0" o.c. 0:025- 1703.1 13.0 4.4 Wood, 2x4, 16" o.c. 0.057 2345.9 13.0 0,0 n/a 0,061 169.8 n/a n/a n/a 0.460- 87.8 n/a n/a n/a 0.460 87.8 n/a n/a n/a 0.460 175.5 19.0 n/a 16.0" o.c. 0.048 302.2 0.0 10.0 None 0.081 169.8 Schuller International, Inc. Building Insulation Division P.O. Box 5106 Denver, CO 80217-5108. For Information on the Performance Home Total Insulation System, call 1-500-6543103. This information does not constitute any warranty of energy cost or savings. REM/Gold v 33(c)1996 Architectural Energy Corporation,. Boulder, CO.