HomeMy WebLinkAboutPERMIT SET_110916.pdfDOCUMENT APPROVALTENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS.___________________________________ _____________________________________________ _____________________________________________ ___________TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATEALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN-OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT.THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.GENERAL PROJECT NOTES1. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TOBASIC DESIGN-BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THEDESIGN-BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEYFIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL ORPLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARYENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONALINFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE MECHANICAL,ELECTRICAL AND PLUMBING DESIGN-BUILD CONTRACTORS SHALL COMPLY WITH ALLAPPLICABLE STATE AND LOCAL BUILDING CODES.FIRE SUPPRESSION AND FIRE ALARMSYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN-BUILD CONTRACTOR ANDMUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES.FIRESUPPRESSION AND FIRE ALARM DESIGN-BUILD CONTRACTORS ARE RESPONSIBLE FORCOMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS.2. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESEDRAWINGS.NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEINGPROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS ANDFLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT ISBEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IFADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUSTCOMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND PROVIDEADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASEOF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLEOFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDINGOWNER/LANDLORD.4. RELOCATE AIR-SUPPLY DIFFUSERS AND RETURN-AIR GRILLES AS REQUIRED. PROVIDEPROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES.CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES ASREQUIRED BY CODE.5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICALDESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OROTHER CONFLICTS.6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESEDRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OFELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OFTHE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TONOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONALPLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES.7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHERAPPLICABLE CODES.8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWERAND DATA OUTLETS AS REQUIRED.9. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE G.F.C.I.10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TOBOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS ANDPROVIDING APPROPRIATE TERMINALS AT FACE PLATE.11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCHPLATES TO MATCHEXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TOPURCHASE.12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN.REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THETENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROMWORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLEFOR WIRING THE BASE PANELS OF THE WORKSTATIONS.13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURESPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICALCONDUITS TO JUNCTION BOXES.14. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS INEXISTING SPACES. CONSULT WITH LANDLORD.15. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDENEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES.16. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A.REQUIREMENTS.17. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLECOVER PLATE.18. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS,SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED.19. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC.EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWERSOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURESSHOWN ON PLAN ARE FOR REFERENCE ONLY.20. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCYSPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM &DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONALBUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONSOF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION.FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIREXPENSE.21. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTIONDEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATUREWALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT-INSTALLED ITEMS(I.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS).MECHANICAL &ELECTRICAL NOTES1. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANABUILDING CODE FOR CLASS A FIRE RATINGS.2. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUMASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS,CORNER BEADS, ETC.)3. ALL NEW PLATES AND SWITCHES ARE TO MATCH EXISTING COLOR, UNLESS OTHERWISENOTED. REMOVE ALL PLATES BEFORE PAINTING AND REATTACH AFTERWARDS.CONTRACTOR TO CONFIRM EXISTING COLOR PRIOR TO PURCHASING NEW.4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISHCOATS.5. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOROPENINGS AS NOTED ON FINISH PLAN (I.E. WHERE VCT MEETS CARPET).6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERENEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK.PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDINGOWNER.7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED.8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TOMATCH ADJACENT WALL FINISH.9. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO SCHOTTDESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALLMILLWORK.10. REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISHINFORMATION.11. ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT.12. ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCTMANUFACTURER.FINISH NOTES1. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BEPROVIDED UNDER THE GENERAL CONTRACT.2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE(A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK.3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THETENANT AND SCHOTT DESIGN PRIOR TO FABRICATION.4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ONPLANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS IN FIELD. REPORT ANYDISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKEADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOINGSO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS.5. VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATIONDRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELYREPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERALCONTRACTOR.6. REFER TO MILLWORK SECTIONS & ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTICLAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED.BACKSPLASHES TO BE FIELD APPLIED.7. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS(CUSTOM PLASTIC LAMINATE OR PRE-MANUFACTURED STOCK CABINETRY).8. TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, ANDCABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED.MILL/CASEWORK NOTES1. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TODETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE ITEMS.2. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED,DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLYNOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERSDURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD,PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOTSTRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THEFIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OROTHERWISE LOAD-BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THATMAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISECAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO ORAROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FORINADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM.3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDINGTHOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSEITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS OFWHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S REQUESTS.4. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THEBUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE INTHEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAININGAREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BYOWNER.5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, ORDASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN.VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION.6. REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES ASREQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTINGCONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTINGFINISHES TO REMAIN.7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED.SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION.8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRIDINSTRUCTIONS.9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TOREMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSIONEQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THECONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANYSUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISEBEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THEOWNER'S USE IN THE PROJECT.10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION)REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDINGBUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES,AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS, AND PLTC CABLES.REFER TO SECTION 300.21.11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING,MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BECLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS ANDGOVERNING SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALLTERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN"AS-BUILT" SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS.12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDINGOWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS,DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY.DEMOLITION NOTEST111 COVER SHEET AND GENERAL PROJECT NOTESL100 LIFE SAFETY PLAND111 DEMOLITION PLANA111 ARCHITECTURAL FLOOR PLANA121 REFLECTED CEILING PLAN: HVAC / LIGHTINGA131 FINISH PLANA211 DOOR SCHEDULE / INTERIOR DETAILSE111 ELECTRICAL PLANINDEX OF DRAWINGSVICINITY MAPNOT TO SCALECOVER SHEET ANDGENERAL NOTEST111= AREAOF WORK TENANT SPACENOT TO SCALEKEY PLAN - 6TH FLOORDESCRIPTIONDATEISSUE11.09.16PERMIT SETREVISONSDESCRIPTIONMARK DATE DBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBERDRAWN BYPROJ. MGRAUTOBASE DOWNSIZEMERIDIAN TOWER, 6TH FLOORJJMJ2016.4966TH FLOORSNIGGOCSR.DDOTARCHITECTINDIANASTATE OFDERETSIGERNo.1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDINGCONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE .2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE ANDLOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THECURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK.3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THEDRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONSOR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIARWITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTSOF THE SCOPE OF WORK.4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERALCONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONSPREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS.NOTED DIMENSIONS TAKE PRECEDENCE.5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANYDISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTT DESIGN, INC.6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALLON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALSSTORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL,AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THECONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWNACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE.7. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKINGHOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURINGHOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS ANDWEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONSOF ADJACENT TENANTS.8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALLCOORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THEOWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDERFOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, ORDESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THECONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES.9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUTPRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITHAPPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLYSUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION.10. SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, ANDSHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS,SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FORMAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES.11. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUPPROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TOCONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT.12. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FORSTAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKINGCONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIESSHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USEDBY CONSTRUCTION CREWS.13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OFDAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUSTPARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS @ 24"O.C., INSULATION AND 6MIL VAPOR BARRIER ON EACH SIDE.14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVEREDBETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OFTHOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTINGMECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES ASINDICATED ON THE CEILING PLAN).15. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY,PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THATOF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE.16. PROVIDE FIRE-TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMSINCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC.17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FORAPPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TODEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOTINDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER.18. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENTTIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OFMATERIALS AND EQUIPMENT.19. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITYSTANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERALCONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITHALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL,MECHANICAL, AND ELECTRICAL CONSTRUCTION.20. ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BYSCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER.21. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHERTRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANYCONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDERDURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT.22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDINGMACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOTATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDEDAS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED.23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAININGWALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSIONJOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS.24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCHDEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPAREFOR FINISH.25. ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITHTHE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS.26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPONCOMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BECLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THATREPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERALCONTRACTOR INSTALLED APPLIANCE S WORK & DO NOT LEAK.27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, ORINSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT.28. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUMBOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALEDRAWINGS. WRITTEN DIMENSIONS GOVERN.29. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS.REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDINGSTANDARD.30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTSREGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERALCONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS ANDSUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMITDEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERALCONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTORAGREEMENT.31. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITHAPPROVED FIRE-RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS.32. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATEDPARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIREDAMPERED IF REQUIRED.33. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR ANDWALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEWCONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED.1. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIREEXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITHOWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVELDISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THEGENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN,INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRESPRINKLER SYSTEM.3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE,THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES ANDREGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRESUPPRESSION SYSTEMS.4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, ANDSHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCALAUTHORITIES HAVING JURISDICTION OVER THE PROJECT.5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDEMISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE.FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK.FIRE PROTECTION NOTES= AREAOF WORK COMMONCORRIDOR
xCONFERENCE63228'-8"13'-5"STG.631FEFEFEENTRY601OPEN OFFICE602xBREAK60336'-2" 11'-11"xOFFICE60412'-9"9'-2"xOFFICE60512'-9" 13'-4"xOFFICE60612'-9"10'-1"xOFFICE60712'-9" 14'-4"xOFFICE60711'-6" 14'-8"xOFFICE60811'-6" 16'-9"xOFFICE 60916'-2" 11'-6"xOFFICE 61014'-7" 11'-5"xCONF.61112'-9"14'-4"xOFFICE 61212'-9" 10'-0"xOFFICE 61312'-9" 8'-9"xOFFICE 61412'-9" 14'-3"xOFFICE 61514'-2" 13'-3"xOFFICE 61610'-1" 13'-7"xSTG. 6178'-6" 14'-10"xCONFERENCE 61821'-8" 15'-11"xOFFICE 6199'-10"13'-5"xOFFICE 62015'-2"14'-11"xOFFICE 62116'-0" 16'-2"xOFFICE 62222'-0" 19'-10"xOFFICE 62311'-0" 10'-10"xSM. CONF62411'-9" 10'-6"xSTG. 6256'-4" 6'-9"xCOFFEE/COPY62615'-7"14'-8"xOFFICE 6279'-0"12'-4"xOFFICE 6289'-0"12'-4"xSTG. 6298'-8" 13'-0"xSTG. 6308'-8" 13'-0"xCONFERENCE 63329'-8" 22'-0"xCONFERENCE 63434'-11"16'-2"xSTG.63511'-10" 5'-3"OPEN OFFICE636xSERVER63910'-5" 19'-10"LIFE SAFETYL100LIFE SAFETY PLANDESCRIPTIONDATEISSUE11.09.16PERMIT SETREVISONSDESCRIPTIONMARK DATE DBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBERDRAWN BYPROJ. MGRAUTOBASE DOWNSIZEMERIDIAN TOWER, 6TH FLOORJJMJ2016.4966TH FLOORNSNIGGOCSR.DDOTARCHITECTINDIANASTATE OFDERETSIGERNo.1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PERNEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTSCONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IFTHE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ONPLAN ARE FOR REFERENCE ONLY.2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANYOTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TOMEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI ORTENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT INCONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILDSERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FORTHE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLERSYSTEM.4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIREDDRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATEDDOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVINGJURISDICTION OVER THE PROJECT.5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW ANDEXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPEAND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANYPOINT TO A VISIBLE EXTINGUISHER.LIFE SAFETY NOTESL1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTIONDETAILS.L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARMNOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXITSIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS ASREQUIRED TO MEET ALL LOCAL AND STATE CODES.GENERAL NOTES08'16'4'EXISTING ELECTRICAL PANEL LOCATIONEXISTING EXITEPEXLEGENDFIRE EXTINGUISHEREXIT SIGNFEEMERGENCY LIGHTFEAREA NOT IN CONTRACTAREA OF WORKTRAVEL DISTANCESCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACETOTAL BUILDING AREATOTAL PROJECT AREACHANGE OF OCCUPANCY CLASS?OCCUPANCY CALCULATIONS SPACE TYPEAREASF PER OCCUPANT OCCUP LOADNOOCCUPANCY CLASSIFICATION B(USINESS)TENANT SPACE SF 100TENANT SPACE NUMBER OF EXITS REQUIRED: 2 PROVIDED: 3SPRINKLER SYSTEM (YES/NO)YES - EXISTING TO REMAINTOTAL AREA OF ACCESSORY USES 0TOTAL AREA ON THE FLOORSFSF/FLOORXSTORIES SFSF26,070 SFACCESSORY AREA EXCEEDS 10% NOFIRE WALLS, AND/OR OCCUPANCYSEPARATIONS (IF REQUIRED)N/A=CODE SUMMARYPREVIOUS USE OF SPACEB(USINESS)ASHRAE 90.1 SUMMARY EXEMPT (SEE A121)BUILT BEFORE 1978? NO20,82923,10126,070 6 156,420209BUILDING CONSTRUCTION TYPE ll-A(B)USINESSEXEXTRAVEL DISTANCE = 178'-0"TRAVEL DISTANCE = 176'-9"EPOCCUPANCY CALCULATIONS SPACE TYPEAREASF PER OCCUPANT OCCUP LOADCOMMON CORRIDOR SF 100COMMON CORRIDOR NUMBER OF EXITS REQUIRED: 2 PROVIDED: 22,272 23TRAVEL DISTANCE = 82'-8"5,843 SQ. FT.
DEMOLITION PLANDEMOLITION PLAND111AREA NOT IN CONTRACTAREA OF WORKDESCRIPTIONDATEISSUE11.09.16PERMIT SETREVISONSDESCRIPTIONMARK DATE DBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBERDRAWN BYPROJ. MGRAUTOBASE DOWNSIZEMERIDIAN TOWER, 6TH FLOORJJMJ2016.4966TH FLOORN4' 8'016'SNIGGOCSR.DDOTARCHITECTINDIANASTATE OFDERETSIGERNo.ELECTRIC OUTLET(S)DATA ORCOMMUNICATIONOUTLETNOTE: EXISTING FIXTURES THAT ARE REMOVEDCAN BE REUSED IF IN GOOD CONDITION.EXISTING TO BE REMOVED EXISTING TO REMAINWALLDOOR AND FRAMEWINDOW / SIDELIGHTWALLDOOR AND FRAMECEILING GRID ANDTILES, 2'x4'SUPPLY AIR DIFFUSERSLIGHT FIXTURE,FLUORESCENT, 2'x4'LIGHT FIXTURE, CANLIGHT SWITCHLIGHT FIXTURE,FLUORESCENT, 2'x2'WINDOW / SIDELIGHTCEILING GRID ANDTILES, 2'x2'LIGHT FIXTURE, TRACKLIGHT FIXTURE, SCONCELIGHT FIXTURE,PENDANTEXIT LIGHTLEGENDLIGHT FIXTURE,FLUORESCENTEXHAUST FANEMERGENCY LIGHTPARTIAL HEIGHT WALLPARTIAL HEIGHT WALLPLAN NOTESREMOVE AND RELOCATE EXISTING RECEPTION DESK AS SHOWNON A111. COORDINATE WITH TENANT ON EXACT LOCATION.MOSAIC TILE ON DESK TO BE REMOVED AND RETILE WITH NEW, SEEFINISH PLAN FOR NEW TILE DETAILS.SALVAGE EXISTING GLASS DOORS FOR RELOCATION. SEE DOORSCHEDULE ON SHEET A211 FOR MORE DETAILS.REMOVE AND RELOCATE PROJECTORS AND CEILING MOUNTEDSCREENS TO NEW CONFERENCE ROOMS.A/V CONSULTANTS TOSURVEY AND ADVISE \CONTRACTOR OF FINAL LAYOUT ANDCOORDINATE RELOCATION OF A/V SWITCHES AS REQUIRED.REMOVE EXISTING RECEPTACLE AND/OR SWITCH AS SHOWN.PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED.REMOVE DRYWALL CEILING AS SHOWN AND REPLACE WITH NEWGRID. SEE A121 FOR MORE DETAILS.SALVAGE AND COORDINATE POSSIBLE RELOCATION OFCASEWORK AND/OR MAIL SLOTS WITH TENANT.VERIFY IN FIELD IF EXISTING FLOOR CORE CAN BE ACCESSED PERNEW WALL PLACEMENT. IF SO, VERIFY WITH TENANT IF IT SHOULDREMAIN IN PLACE.SALVAGE WALL SCONCES AND COORDINATE POSSIBLERELOCATION WITH TENANT.SALVAGE PENDANTS ABOVE RECEPTION DESK AND COORDINATERELOCATION WITH TENANT.REMOVE EXISTING MILLWORK AND CASEWORK.
WALLTHICKNESSPRE-FINISHED ALUMINUMRECEIVER TRIM - FASTEN ATWINDOW SILL AND SET IN ACONTINUOUS BEAD OFCAULK AT WINDOW MULLIONWHERE NEW WALLS MEET.TRIM COLOR TO MATCHBUILDING WINDOWMULLIONS.LINE OF EXISTING WINDOWSILL COVER BELOWCONTINUOUS BEAD OFACOUSTICAL SEALANTMETAL STUDEXISTING WINDOWMULLIONEQUALARCHITECTURALFLOOR PLANA111ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESSSTUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLSARE IN LINE WITH EXISTING WALLS.NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BYCONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLEDACCORDING TO NFPA 10.CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W2". IF NOT,ALTER EXISTING WALL AS REQUIRED TO MATCH "W2".CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W3". IF NOT,ALTER EXISTING WALL AS REQUIRED TO MATCH "W3".REINSTALL MILLWORK RECEPTION DESK SALVAGED FROMDEMOLITION. VERIFY EXACT PLACEMENT WITH TENANT PRIOR TOINSTALLATION.NOT TO SCALEPLAN NOTES DETAILWALL AT MULLIONARCHITECTURAL PLANAREA NOT IN CONTRACTAREA OF WORKWALLDOOR AND FRAME(SEE DOOR SCHEDULE)NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROMDEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.NEW CONSTRUCTION EXISTING TO REMAINWALLDOOR AND FRAMEWINDOW / SIDELIGHTWINDOW / SIDELIGHTARCHITECTURAL LEGENDPARTIAL HEIGHT WALLPARTIAL HEIGHT WALL STANDARD WALL358 " METAL STUDS AT 16" O.C.;ONE LAYER OF 58" TYPE "X" GYPSUM BOARDEACH SIDE;EXTEND WALL TO UNDERSIDE OF CEILING DEMISING WALL TO DECKWITH INSULATION358" METAL STUDS AT 16" O.C.;ONE LAYER OF 58" TYPE "X" GYPSUM BOARDEACH SIDE;EXTEND WALL TO UNDERSIDE OF DECK;FIBERGLASS SOUND BATT INSULATION INSIDEWALLW1 DEMISING WALL WITH SECURITY MESH358 " METAL STUDS AT 16" O.C.;ONE LAYER OF 58" TYPE "X" GYPSUM BOARDEACH SIDE;EXTEND WALL TO UNDERSIDE OF CEILING;FIBERGLASS SOUND BATT INSULATION INSIDEWALL AND 2'-0" SOUND BATT INSULATIONEACH SIDE OF WALL ABOVE CEILING;PROVIDE METAL SECURITY MESH ON TOP OFWALL ABOVE CEILING TO DECKW2 WALL WITH INSULATION358 " METAL STUDS AT 16" O.C.;ONE LAYER OF 58" TYPE "X" GYPSUM BOARDEACH SIDE;EXTEND WALL TO UNDERSIDE OF CEILING;FIBERGLASS SOUND BATT INSULATION INSIDEWALL AND 2'-0" EACH SIDE OF WALL ABOVECEILINGW3W4WALL TYPESW2NOTE:ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THISPROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.A1111TYP.A1111DESCRIPTIONDATEISSUE11.09.16PERMIT SETREVISONSDESCRIPTIONMARK DATE DBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBERDRAWN BYPROJ. MGRAUTOBASE DOWNSIZEMERIDIAN TOWER, 6TH FLOORJJMJ2016.4966TH FLOORN4' 8'016'SNIGGOCSR.DDOTARCHITECTINDIANASTATE OFDERETSIGERNo.1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.GENERAL NOTES
REFLECTEDCEILING PLANA121CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH ATTHIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.NOTE THAT RELOCATED PENDANTS ARE NOT NECESSARILYCENTERED IN TILE. CONFIRM WITH WITH TENANT ON EXACTLOCATION OF PENDANTS PRIOR TO INSTALLATION.PROVIDE NEW CEILING GRID TO MATCH EXISTING GRID SIZE ANDSTYLE. DESIGN INTENT IS FOR GRID TO APPEAR CONTINUOUS.COORDINATE WITH LANDLORD ON IDEAL LOCATION FORCOMMON AREA LIGHT CONTROLS.COORDINATE WITH TENANT ON RELOCATION OF ALL PROJECTORSAND CEILING MOUNTED SCREENS. RELOCATE SWITCHES FOREQUIPMENT AS REQUIRED. A/V CONSULTANT TO SURVEY ANDADVISE CONTRACTOR OF FINAL LAYOUT AND LOCATIONS.1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS2'x4'AT 10'-0" A.F.F. TILES ARE 2 x 4 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGEDGRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING.2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATEUNIFORM LOOK.3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC.EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWERSOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURESSHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCEROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCHDEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TODO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.GENERAL NOTESPLAN NOTESSWITCH, PROJECTOR SCREENLIGHT CIRCUITLIGHT SWITCH, DIMMERLIGHT SWITCH, 3-WAYLIGHT SWITCHEXIT LIGHT FIXTURELIGHT FIXTURE,PENDANTRECESSED LIGHTFIXTURELIGHT FIXTURE, 2'x4',FLUORESCENT, PARABOLICRELOCATEDDIFFUSER, LAY-IN, 4"x4'RELOCATEDDIFFUSER, LAY-IN, 1'x4'RELOCATEDDIFFUSER, LAY-IN, 2'x2'CEILING GRID,SUSPENDED, 2'x2'CEILING GRID,SUSPENDED, 2'x4'NIGHT LIGHTNOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORKIS TO BE INSTALLED PER THIS SHEET.NEW OR RELOCATED EXISTING TO REMAINWALL SCONCE LIGHTFIXTURELIGHT FIXTURE,PENDANTEXIT LIGHT FIXTURESWITCH, PROJECTOR SCREENLIGHT CIRCUITLIGHT SWITCH, DIMMERLIGHT SWITCH, 3-WAYLIGHT SWITCHCEILING GRID,SUSPENDED, 2'x2'CEILING GRID,SUSPENDED, 2'x4'EXISTING DIFFUSER, LAY-IN,4"x4'EXISTING DIFFUSER, LAY-IN, 1'x4'EXISTING DIFFUSER, LAY-IN, 2'x2'CEILING GRID, SUSPENDED,4'x4' TEES TO COMPLETEGRIDCEILING GRID,SUSPENDED, 4'x4'GYPSUM BOARDCEILINGLIGHT FIXTURE, 2'x4',FLUORESCENT, PARABOLICLEGENDREFLECTED CEILING PLANAREA NOT IN CONTRACTAREA OF WORKRECESSED LIGHTFIXTUREWALL SCONCE LIGHTFIXTUREDESCRIPTIONDATEISSUE11.09.16PERMIT SETREVISONSDESCRIPTIONMARK DATE DBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBERDRAWN BYPROJ. MGRAUTOBASE DOWNSIZEMERIDIAN TOWER, 6TH FLOORJJMJ2016.4966TH FLOORN4' 8'016'SNIGGOCSR.DDOTARCHITECTINDIANASTATE OFDERETSIGERNo.EMERGENCY LIGHTFIXTUREEMERGENCY LIGHT FIXTURE1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPEAND IS OUTLINED IN THESE DRAWINGS.NO NEW MAINMECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEINGPROVIDED. ALL MECHANICAL WORK IS LIMITED TORELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALLLAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEINGADDED; MECHANICAL CONTRACTOR IS TO NOTIFYAPPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SOTHAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLYWITH THE INDIANA MECHANICAL CODE AND ALL OTHERAPPLICABLE CODES.MECHANICAL NOTESEXHAUST FAN, 2'x2'EXISTING EXHAUST FAN, 2'x2'GYPSUM BOARD CEILINGSWITCH, GARBAGE DISPOSALSWITCH, GARBAGE DISPOSAL4.UNLESS NOTED OTHERWISE, THE LIGHTS SHOWN AS"NEW OR RELOCATED" ARE TO BE RELOCATED FROM APREVIOUS LOCATION AS SHOWN ON THE DEMOLITIONPLAN. THE DESIGN INTENT IS LESS THAN 50% OF THELIGHTS ARE ACTUALLY BEING REPLACED WITH NEWAND OVERALL WATTAGE IS STAYING THE SAME ORDECREASING. LAYOUT SHOWN IS INTENDED TO MEETASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTORIS RESPONSIBLE FOR COMPLIANT INSTALLATION. IFADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,CONTRACTOR MUST NOTIFY SDI.5. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TOBE OCCUPANCY SENSORS, PROVIDE COMBO UNITWITH BOTH ULTRASONIC AND INFRARED TECHNOLOGYWITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED,OR RELAY TIME CLOCK CONTROLS (COORDINATE WITHSDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE.6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILDSCOPE AND IS OUTLINED IN THESE DRAWINGS. ALLELECTRICAL WORK IS LIMITED TO ADDITIONS ORRELOCATIONS OF ELECTRICAL OUTLET DEVICES ANDLIGHTING THAT DO NOT EXCEED THE CAPACITY OF THEEXISTING ELECTRICAL SERVICE IN THE BUILDING.ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLEPARTIES IF ADDITIONAL WORK IS REQUIRED SO THATADDITIONAL PLANS CAN BE FILED AND MUST COMPLYWITH ALL APPLICABLE CODES.A2111LARGE PENDANTFIXTURE
FINISH PLANA131TILEMFG: TBD (ASSUME $25 MATERIAL COST PER SQUARE FOOT) COLOR: -- PATTERN: --FINISH PLANPLAN NOTESAREA NOT IN CONTRACTAREA OF WORKDESCRIPTIONDATEISSUE11.09.16PERMIT SETREVISONSDESCRIPTIONMARK DATE DBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBERDRAWN BYPROJ. MGRAUTOBASE DOWNSIZEMERIDIAN TOWER, 6TH FLOORJJMJ2016.4966TH FLOORN4' 8'016'SNIGGOCSR.DDOTARCHITECTINDIANASTATE OFDERETSIGERNo.ALL FINISHES TO BE SELECTED. FINISHES SHALL MEET ALL CLASS A FIRE RATINGS AND COMPLYWITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE.EXISTING CARPET AND BASE TO REMAIN UNLESS NOTEDOTHERWISE.USE TENANT'S OVERSTOCK CARPET IN THIS ROOM. GC TO VERIFYEXACT YARDAGE. IF NO REMNANT IS LARGE ENOUGH, PROVIDENEW BROADLOOM CARPET (MATERIAL ALLOWANCE OF $18 PERSQUARE YARD INSTALLED)PROVIDE NEW WOOD BASE IN ELEVATOR LOBBY AREA TO MATCHSIZE AND STYLE OF ALL OTHER FLOORS. WOOD TO BE PAINTEDPT4.DOORS (AND METAL FRAMES) IN CORRIDOR THAT ARE CURRENTLYPAINTED ARE TO RECEIVE NEW COAT OF PAINT, PT3.REPLACE EXISTING MOSAIC TILE ON RECEPTION DESK WITH NEWMT1. ASSUME $25 MATERIAL COST PER SQUARE FOOT.NO WORK IN THIS AREA. ALL FINISHES TO REMAIN.CARPETFLOOR COVERINGSMFG: SHAW TYPE: TILE PATTERN: CATALYST 59579 COLOR: TORTOISE SHELL 64740 INSTALLATION: MONOLITHIC WITH "STRIPES"ORIENTED EAST/ WEST AS SHOWN BY ARROWS.WALL BASEMFG: JOHNSONITE TYPE: 4" VINYL COVE, 18" GAUGE COLOR: 44 DARK BROWNPAINT / WALLCOVERINGMFG: DL COUCH, SOURCE ONE TYPE: VINYL PATTERN: RYUGU COLOR: SGY-11 CREAMLEGENDMFG: DL COUCH, SYMPHONY TYPE: VINYL PATTERN: CAVATINA SILK COLOR: MIDNIGHT OASISMFG: TBD TYPE: PATTERN: COLOR: INSTALLATION:MFG: TBD TYPE: PATTERN: COLOR: INSTALLATION:MFG: SHERWIN WILLIAMS TYPE: LATEX COLOR: SW6143 BASKET BEIGE FINISH: EGGSHELLMFG: SHERWIN WILLIAMS TYPE: LATEX COLOR: NACREFINISH: EGGSHELL (WHEN USED ON WALLS)SEMI-GLOSS (WHEN USED ON ELEVATOR DOORS AND FRAMES)MFG: TBD *PROVIDE MATTERIAL ALLOWANCE OF $25 PER SQUARE YARD INSTALLED. TYPE: TBD PATTERN: TBD COLOR: TBD INSTALLATION: TBDNOTE: USE TENANT'S OVERSTOCK VINYLWALLCOVERINGMFG: TYPE: PATTERN: COLOR:VINYL COMPOSITION TILEMFG: TBD SIZE: 12"x12" PATTERN: --- COLOR: ---MFG: JOHNSONITE TYPE: 4" VINYL COVE, 18" GAUGE COLOR: TBD
F26'-4"2"8'-2"8'-0"2"F18'-2"3'-0"3'-4"2"2"8'-0"2"2"8'-0"D13'-0"1'-0"8"7"7"8'-0"3'-0"D214" TEMPEREDGLASSDOOR SCHEDULEINTERIOR DETAILSA2113'-0"x8'-0"x134"RELOCATED EXISTINGD1--SOLID COREBIRCH VNR.STAIN TOMATCH EXIST.F1 TIMELY-- -- -- -- ----R1. REUSE EXISTING GLASS ENTRY DOORS AND RELOCATE TO NEWLOCATION AS SHOWN ON PLAN. COORDINATE EXACT SECURITYAND HARDWARE REQUIREMENTS WITH TENANT AND LANDLORD.R2. COORDINATE DOOR HARDWARE AND SECURITY REQUIREMENTS WITHLANDLORD.DOOR SCHEDULENUM.DIMENSIONSDOORS FRAMETYPE MATERIAL FINISHHARDWARESETREMARKSTYPE MATERIAL FINISHMATCHEXIST.CL CLOSERCH COAT HOOKCR CARD READER BY TENANT (N.I.C.)DB DEADBOLTDL DUMMY LEVEREL ELECTROMAGNETIC LOCK (PER IBC 2012)ES ELECTRIC STRIKE BY TENANT (N.I.C.)H HOLD OPENKP KICK PLATEKS KICK STOPOL OFFICE LOCKSETPH PANIC HARDWAREPL PRIVACY LOCKSETPP PUSH/PULLPS PASSAGE LATCHSETPV PIVOT HINGERL ROLLER LATCHESSL STOREROOM LOCKSETTS TOP STRIKESHARDWARE LEGEND1. REUSE DOORS FROM DEMOLITION WHERE POSSIBLE.PROVIDE NEW BUILDING STANDARD DOORS MATCHINGEXISTING VENEER AS REQUIRED. STAIN NEW DOORS TOMATCH EXISTING. PRE-MACHINE NEW DOORS FORCYLINDRICAL LOCKSETS.2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEWDOORS. REUSE EXISTING HARDWARE ON EXISTINGDOORS WHERE POSSIBLE. FOR NEW DOOR HARDWARE,PROVIDE GRADE 2 MINIMUM BUILDING STANDARD.PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEWLOCK AND LATCHSETS.3. PROVIDE NEW BUILDING STANDARD FRAMES ASREQUIRED. REUSE EXISTING FROM DEMOLITION WHEREPOSSIBLE.4. FRAME ALL DOOR ROUGH OPENINGS 4" FROMADJACENT WALL CORNERS UNLESS OTHERWISE NOTEDON PLAN.5. REFER TO TENANT AND LANDLORD FOR KEYINGREQUIREMENTS AND LOCKSETS.6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THESPECIFICATION, PURCHASE, AND INSTALLATION OF ALLACCESS CONTROLLED ELECTRONIC AND/OR MAGNETICHARDWARE AND ASSOCIATED DEVICES. ALLSPECIFICATIONS AND INSTALLATIONS MUST COMPLYWITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANSOF EGRESS.7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:7'-0" HT. TO HAVE 3 HINGESGREATER THAN 7'-0" IN HT. TO HAVE 4 HINGESFINISH TO MATCH HARDWARE SET8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR FRAMESUNLESS OTHERWISE NOTED.9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE)AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDEWOOD BLOCKING BEHIND WALL STOP.DOOR/FRAME NOTESR1DESCRIPTIONDATEISSUE11.09.16PERMIT SETREVISONSDESCRIPTIONMARK DATE DBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBERDRAWN BYPROJ. MGRAUTOBASE DOWNSIZEMERIDIAN TOWER, 6TH FLOORJJMJ2016.4966TH FLOORSNIGGOCSR.DDOTARCHITECTINDIANASTATE OFDERETSIGERNo.DOOR/FRAME TYPES MECHANICAL DIFFUSER RELOCATIONA2111*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATIONEXISTING VAV BOXES ORHEAT PUMP AND MAIN SUPPLYDUCTS TO REMAINRELOCATE DIFFUSERS &FLEXDUCT IF REQUIREDVAV /HEAT PUMP3'-0"x8'-0"x134"D1SOLID COREBIRCH VNR.STAIN TOMATCH EXIST.F1 TIMELYMATCHEXIST.3'-0"x8'-0"x134" (PAIR)D1SOLID COREBIRCH VNR.STAIN TOMATCH EXIST.F2 TIMELYMATCHEXIST.3'-0"x8'-0"x134"D2SOLID COREBIRCH VNR.STAIN TOMATCH EXIST.F1 TIMELYMATCHEXIST.3'-0"x8'-0"x134" (PAIR)D2SOLID COREBIRCH VNR.STAIN TOMATCH EXIST.F2 TIMELYMATCHEXIST.3'-0"x8'-0"x134" (PAIR)D2SOLID COREBIRCH VNR.STAIN TOMATCH EXIST.F2 TIMELYMATCHEXIST.3'-0"x8'-0"x134"D1SOLID COREBIRCH VNR.STAIN TOMATCH EXIST.F1 TIMELYMATCHEXIST.3'-0"x8'-0"x134"D1SOLID COREBIRCH VNR.STAIN TOMATCH EXIST.F1 TIMELYMATCHEXIST.3'-0"x8'-0"x134"D1SOLID COREBIRCH VNR.STAIN TOMATCH EXIST.F1 TIMELYMATCHEXIST.3'-0"x8'-0"x134"D1SOLID COREBIRCH VNR.STAIN TOMATCH EXIST.F1 TIMELYMATCHEXIST.RELOCATED EXISTING-- -- -- -- -- ----R1ES,CL,CR,SLES,CL,CR,SLPSPSPPPPSLR2CL,OLES,CL,CR,SLDL, PL
ELECTRICAL PLANE111PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOORFOR CARD READER (CARD READER BY TENANT). COORDINATEWITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULEFOR MORE DETAILS.COORDINATE EXACT POWER REQUIREMENTS FOR SECURITY ANDACCESS WITH TENANT.COORDINATE WITH TENANT ON RELOCATION OF ALL PROJECTORSAND CEILING MOUNTED SCREENS. A/V CONSULTANT TO SURVEYAND ADVISE CONTRACTOR OF FINAL LAYOUT.COORDINATE EXACT POWER REQUIREMENTS FOR RECEPTIONDESK WITH TENANT.PLAN NOTESELECTRICAL PLANAREA OF WORKPOWER OUTLET, DUPLEXNEW CONSTRUCTION EXISTING TO REMAINPOWER OUTLET,QUADRUPLEXJUNCTION BOXPOWER OUTLET, DUPLEXPOWER OUTLET,QUADRUPLEXJUNCTION BOXBOX, BLANK COVER PLATEBOX, OPENBOX, BLANK COVER PLATEBOX, OPENPOWER POLE FORELECTRICAL AND DATA.PROVIDE JUNCTION BOXABOVE CEILING.POWER AND DATA POLEFLOOR BOX WITH POWERAND DATA, FLUSHMOUNTEDFLOOR BOX WITHJUNCTION BOX ANDDATA, FLUSH MOUNTEDFLOOR BOX WITH POWERAND DATA, FLUSHMOUNTEDFLOOR BOX WITHJUNCTION BOX ANDDATA, FLUSH MOUNTEDDEDICATED CIRCUITDATA/COMMUNICATIONOUTLET (PROVIDE BOXAND PULL STRING ONLY)DATA/COMMUNICATIONOUTLETGROUND FAULT CIRCUITINTERRUPT OUTLETHEIGHT OF ELECTRICALOR DATA DEVICELEGENDCEILING MOUNTEDJUNCTION BOXCEILING MOUNTEDJUNCTION BOXDESCRIPTIONDATEISSUE11.09.16PERMIT SETREVISONSDESCRIPTIONMARK DATE DBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBERDRAWN BYPROJ. MGRAUTOBASE DOWNSIZEMERIDIAN TOWER, 6TH FLOORJJMJ2016.4966TH FLOORN4' 8'016'SNIGGOCSR.DDOTARCHITECTINDIANASTATE OFDERETSIGERNo.CABLE BOX, OPEN1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OFFURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OFTHE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE.3. REFER TO DOOR SCHEDULE AND COORDINATE WITHTENANT/OWNER REGARDING POWER LOCATIONS TOACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/ORMAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THETENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.4. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND ISOUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITEDTO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICESAND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THEEXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICALCONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONALWORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED ANDMUST COMPLY WITH ALL APPLICABLE CODES.GENERAL NOTESAREA NOT IN CONTRACT